首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
"Macromolecules to PDMS transfer" technique relying on the direct entrapment of macromolecules spots during PDMS polymerisation is proposed as an alternative for the easy and simple PDMS surface modification. In the present work, the development of three different applications based on this procedure is presented as proof of the method potentialities. First, C-reactive protein (CRP) sandwich immunoassay using immobilised monoclonal anti-CRP antibodies was developed for sepsis diagnosis. The preserved integrity of the immobilised monoclonal immunoglobulin permitted the sensitive detection of free CRP in human sera (LOD=12.5 microg/L, detection ranging over two decades). Then, rheumatoid arthritis diagnosis through the rheumatoid factor (RF) detection based on rabbit immunoglobulins immobilisation allowed the detection of specific antibodies in human sera samples down to low RF levels (detection range 5.3-485 IU/mL). Finally, the "Macromolecules to PDMS transfer" procedure was used to easily and rapidly produce fibronectin-based cell culture arrays. The successful attachment of HeLa and BALB/3T3 cells was demonstrated with optical microscopy and specific staining of actin and vinculin.  相似文献   

2.
A microfluidic conductimetric bioreactor has been developed. Enzyme was immobilized in the microfluidic channel on poly-dimethylsiloxane (PDMS) surface via covalent binding method. The detection unit consisted of two gold electrodes and a laboratory-built conductimetric transducer to monitor the increase in the conductivity of the solution due to the change of the charges generated by the enzyme-substrate catalytic reaction. Urea–urease was used as a representative analyte-enzyme system. Under optimum conditions urea could be determined with a detection limit of 0.09 mM and linearity in the range of 0.1–10 mM (r = 0.9944). The immobilized urease on the microchannel chip provided good stability (>30 days of operation time) and good repeatability with an R.S.D. lower than 2.3%. Good agreement was obtained when urea concentrations of human serum samples determined by the microfluidic flow injection conductimetric bioreactor system were compared to those obtained using the Berthelot reaction (P < 0.05). After prolong use the immobilized enzyme could be removed from the PDMS microchannel chip enabling new active enzyme to be immobilized and the chip to be reused.  相似文献   

3.
In this work, we develop low-cost microfluidic systems based on polydimethylsiloxane (PDMS) for lab-on-a-chip applications. PDMS microfluidic structures have been fabricated by micromolding, PDMS casting, and plasma bonding processes. The micromolding technique is used to fabricate PDMS slabs with micro-sized grooves, and the complete microchannel is formed by bonding PDMS slab with glass or PDMS substrate. The molding procedure using SU-8 photoresist patterning on silicon wafer, PDMS microchannel fabrication, and PDMS surface treatment using oxygen plasma and TiO2 coating, are discussed. The various parameters for oxygen plasma treatment including RF power and treatment time are studied in order to obtain conditions for good bonding with the glass substrate. The best condition for plasma treatment is found to be the low RF power (8 W) with 5 min treatment time. In addition, TiO2 coating with oxygen plasma treatment has been applied to make PDMS surface more hydrophilic to improve aqueous solution compatilbility. The microfluidic channels for various applications, including sample injection cross channel, micropump channel, T and Y sample mixers, PCR thermocyling chamber and channel, capillary electrophoresis flow channel, and conductimetric systems have been fabricated. Finally, a typical application of the PDMS chip in a flow injection conductimetric system for sodium chloride detection has been demonstrated.  相似文献   

4.
A microfluidic electrochemical immunoassay system for multiplexed detection of protein cancer biomarkers was fabricated using a molded polydimethylsiloxane channel and routine machined parts interfaced with a pump and sample injector. Using off-line capture of analytes by heavily-enzyme-labeled 1 μm superparamagnetic particle (MP)-antibody bioconjugates and capture antibodies attached to an 8-electrode measuring chip, simultaneous detection of cancer biomarker proteins prostate specific antigen (PSA) and interleukin-6 (IL-6) in serum was achieved at sub-pg mL?1 levels. MPs were conjugated with ~90,000 antibodies and ~200,000 horseradish peroxidase (HRP) labels to provide efficient off-line capture and high sensitivity. Measuring electrodes feature a layer of 5 nm glutathione-decorated gold nanoparticles to attach antibodies that capture MP-analyte bioconjugates. Detection limits of 0.23 pg mL?1 for PSA and 0.30 pg mL?1 for IL-6 were obtained in diluted serum mixtures. PSA and IL-6 biomarkers were measured in serum of prostate cancer patients in total assay time 1.15 h and sensor array results gave excellent correlation with standard enzyme-linked immunosorbent assays (ELISA). These microfluidic immunosensors employing nanostructured surfaces and off-line analyte capture with heavily labeled paramagnetic particles hold great promise for accurate, sensitive multiplexed detection of diagnostic cancer biomarkers.  相似文献   

5.
An integrated microfluidic device with injecting, flushing, and sensing functions was realized using valves that operate based on direct electrowetting. The device consisted of two substrates: a glass substrate with driving and sensing electrodes and a poly(dimethylsiloxane) (PDMS) substrate. Microfluidic transport was achieved using the spontaneous movement of solutions in hydrophilic flow channels formed with a dry-film photoresist layer. The injection and flushing of solutions were controlled by gold working electrodes, which functioned as valves. The valves were formed either in the channels or in a through-hole in the glass substrate. To demonstrate the system's applicability to an immunoassay, the detection of immobilized antigens was performed as a partial simulation of a sandwich immunoassay. Human -fetoprotein (AFP) or an anti-human AFP antibody was immobilized on a platinum working electrode in the chamber using a plasma-polymerized film (PPF). By applying a potential to the injection valves, necessary solutions were injected one by one through the channels into a reaction chamber at the center of the chip and incubated for reasonable periods of time. The solutions were then flushed through the flushing valve and absorbed in a filter paper placed under the device. After incubation with the corresponding antibodies labeled with glucose oxidase (GOD), electrochemical detection was conducted. In both cases, the obtained current depended on the amount of immobilized antigen. The calibration curves were sigmoidal, and the detection limit was 0.1 ng. The developed microfluidic system could potentially be a fundamental component for a micro immunoassay of the next generation.  相似文献   

6.
This study reports a microfluidic chip integrated with an arrayed immunoassay for surface plasmon resonance (SPR) phase imaging of specific bio-samples. The SPR phase imaging system uses a surface-sensitive optical technique to detect two-dimensional (2D) spatial phase variation caused by rabbit immunoglobulin G (IgG) adsorbed on an anti-rabbit IgG film. The microfluidic chip was fabricated by using micro-electro-mechanical-systems (MEMS) technology on glass and polydimethylsiloxane (PDMS) substrates to facilitate well-controlled and reproducible sample delivery and detection. Since SPR detection is very sensitive to temperature variation, a micromachine-based temperature control module comprising micro-heaters and temperature sensors was used to maintain a uniform temperature distribution inside the arrayed detection area with a variation of less than 0.3 degrees C. A self-assembled monolayer (SAM) technique was used to pattern the surface chemistry on a gold layer to immobilize anti-rabbit IgG on the modified substrates. The microfluidic chip is capable of transporting a precise amount of IgG solution by using micropumps/valves to the arrayed detection area such that highly sensitive, highly specific bio-sensing can be achieved. The developed microfluidic chips, which employed SPR phase imaging for immunoassay analysis, could successfully detect the interaction of anti-rabbit IgG and IgG. The interactions between immobilized anti-rabbit IgG and IgG with various concentrations have been measured. The detection limit is experimentally found to be 1 x 10(-4)mg/ml (0.67 nM). The specificity of the arrayed immunoassay was also explored. Experimental data show that only the rabbit IgG can be detected and the porcine IgG cannot be adsorbed. The developed microfluidic system is promising for various applications including medical diagnostics, microarray detection and observing protein-protein interactions.  相似文献   

7.
In this study, antibody-based protein microarrays for high-throughput immunoassay were fabricated on an aldehydemodified indium-tin oxide glass plate using the electrospray deposition (ESD) method and their characteristics were evaluated immunochemically. The microarrays were also integrated into microfluidic chips with a polydimethylsiloxane (PDMS) micro-channel to detect human cytokines, which were quantitatively analyzed with a high resolution chargecoupled device. Simultaneous detection of various antigens was performed using the microarrays with considerable sensitivity (ca. 100 pg/mL). The results of this study indicate that microfluidic chip comprising a protein microarray formed by the ESD method and a PDMS micro-channel could be easy to handle, and offers high-throughput detection of molecular biomarkers.  相似文献   

8.
We report a microfluidic sensing platform for the detection of thyroglobulin (Tg) using competitive protein adsorption. Serum Tg is a highly specific biomarker for residual thyroid tissue, recurrence and metastases after treatment for differentiated thyroid cancer (DTC). Conventional Tg detection techniques require complicated immobilization of antibodies and need to form a sandwich assay using additional secondary antibodies to enhance the sensitivity. We present a fundamentally different sensing technique without using antibody immobilization on a microfluidic platform. We engineer two surfaces covered by two known proteins, immunoglobulin G (IgG) and fibrinogen, with different affinities onto the surfaces. The microfluidic device offers a selective protein sensing by being displaced by a target protein, Tg, on only one of the surfaces. By utilizing the competitive protein adsorption, Tg displaces a weakly bound protein, IgG; however, a strongly bound protein, fibrinogen, is not displaced by Tg. The surface plasmon resonance (SPR) sensorgrams show that five human serum proteins, albumin, haptoglobin, IgG, fibrinogen and Tg, have different adsorption strengths to the surface and the competitive adsorption of individuals controls the exchange sequence. The adsorption and exchange are evaluated by fluorescent labeling of these proteins. Tg in a protein mixture of albumin, haptoglobin, and Tg is selectively detected based on the exchange reaction. By using the technique, we obviate the need to rely on antibodies as a capture probe and their attachment to transducers.  相似文献   

9.
A sensitive determination of a synthetic fluoroquinolone antibacterial agent, moxifloxacin (MOX), by an enhanced chemiluminescence (CL) method using a microfluidic chip is described. The microfluidic chip was fabricated by a soft‐lithographic procedure using polydimethyl siloxane (PDMS). The fabricated PDMS microfluidic chip had three‐inlet microchannels for introducing the sample, chemiluminescent reagent and oxidant, and a 500 µm wide, 250 µm deep and 82 mm long microchannel. An enhanced CL system, luminol–ferricyanide, was adopted to analyze the MOX concentration in a sample solution. CL light was emitted continuously after mixing luminol and ferricyanide in the presence of MOX on the PDMS microfluidic chip. The amount of MOX in the luminol–ferricyanide system influenced the intensity of the CL light. The linear range of MOX concentration was 0.14–55.0 ng/mL with a correlation coefficient of 0.9992. The limit of detection (LOD) and limit of quantification (LOQ) were 0.06 and 0.2 ng/mL respectively. The presented method afforded good reproducibility, with a relative standard deviation (RSD) of 1.05% for 10 ng/mL of MOX, and has been successfully applied for the determination of MOX in pharmaceutical and biological samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
This paper describes the fabrication, the characterization and the applications of a capillary electrophoresis microchip. This hybrid device (glass/PDMS) features channels and optical waveguides integrated in one common substrate. It can be used for electrophoretic separation and fluorimetric detection of molecules. The microfluidic performance of the device is demonstrated by capillary zone and gel electrophoresis of proteins.  相似文献   

11.
This paper reports the pre-concentration of C-reactive protein (CRP) antigen with packed beads in a microfluidic chamber to enhance the sensitivity of the miniaturized fluorescence detection system for portable point-of-care testing devices. Although integrated optical systems in microfluidic chips have been demonstrated by many groups to replace bulky optical systems, the problem of low sensitivity is a hurdle for on-site clinical applications. Hence we integrated the pre-concentration module with miniaturized detection in microfluidic chips (MDMC) to improve analytical sensitivity. Cheap silicon-based photodiodes with optical filter were packaged in PDMS microfluidic chips and beads were packed by a frit structure for pre-concentration. The beads were coated with CRP antibodies to capture antigens and the concentrated antigens were eluted by an acid buffer. The pre-concentration amplified the fluorescence intensity by about 20-fold and the fluorescence signal was linearly proportional to the concentration of antigens. Then the CRP antigen was analyzed by competitive immunoassay with an MDMC. The experimental result demonstrated that the analytical sensitivity was enhanced up to 1.4 nM owing to the higher signal-to-noise ratio. The amplification of fluorescence by pre-concentration of bead-based immunoassay is expected to be one of the methods for portable fluorescence detection system.  相似文献   

12.
Microchannel is basic functional component of microfluidic chip and every step-forward of its construction technique has been receiving concern all over the world. The present work describes a novel, rapid and simple fabrication technique for building 3D microchannels in poly(dimethyl siloxane) (PDMS) elastomer. These microchannels were used for rapid detection of antigens (E. coli) by quantum dot (QD) based approach. Luminescent QD (CdTe) were synthesized by aqueous method and characterized using high resolution transmission electron microscopy (HRTEM), fluorescence spectroscopy and X-ray diffraction (XRD). The QDs were functionalized with anti-E. coli antibodies for immuno-detection. The reported process allowed easier and faster method of fabrication of circular 3D micochannels and demonstrated their potential use in an immuno-biosensor device.  相似文献   

13.
Detection of Escherichia coli K-12 in phosphate buffered saline (PBS) was demonstrated in a Y-channel polydimethylsiloxane (PDMS) microfluidic device through optical fiber monitoring of latex immunoagglutination. The latex immunoagglutination assay was performed for serially diluted E. coli solutions using 0.92-microm highly carboxylated polystyrene particles conjugated with polyclonal anti-E. coli. Pre-treatments such as cell lysis or culturing to enhance the signal were not used. Proximity optical fibers around the view cell of the device were used to quantify the increase in 45 degrees forward light scattering of the immunoagglutinated particles. In order to reduce false positive signals caused by antibodies binding to non-viable E. coli cells or free antigens in solution, target solutions were washed three times, and then the results were compared to non-washing treatments. The detection limit was found to be less than 10 cfu ml(-1) (1 cfu per device) without PBS washing (thus detecting non-viable cells and free antigens), or less than 40 cfu ml(-1) (4 cfu per device) with PBS washing (thus detecting viable E. coli cells only).  相似文献   

14.
Wu H  Tian Y  Liu B  Lu H  Wang X  Zhai J  Jin H  Yang P  Xu Y  Wang H 《Journal of proteome research》2004,3(6):1201-1209
The design and characterization of titania-based and alumina-based Poly(dimethylsiloxane) (PDMS) microfluidics enzymatic-reactors along with their analytical features in coupling with MALDI-TOF and ESI-MS were reported. Microfluidics with microchannel and stainless steel tubing (SST) were fabricated using PDMS casting and O(2)-plasma techniques, and were used for the preparation of an enzymatic-reactor. Plasma oxidation for the PDMS microfluidic system enabled the channel wall of the microfluidics to present a layer of silanol (SiOH) groups. These SiOH groups act as anchors onto the microchannel wall linked covalently with the hydroxyl groups of trypsin-encapsulated sol matrix. As a result, the trypsin-encapsulated gel matrix was anchored onto the wall of the microchannel, and the leakage of gel matrix from the microchannel was effectively prevented. A feature of the microfluidic enzymatic-reactors is the feasibility of performing on-line protein analysis by attached SST electrode and replaceable tip. The success of trypsin encapsulation was investigated by AFM imaging, assay of enzymatic activity, CE detection, and MALDI-TOF and ESI-MS analysis. The lab-made devices provide an excellent extent of digestion even at a fast flow rate of 7.0 microL/min, which affords the very short residence time of ca. 2 s. With the present device, the digestion time was significantly shortened compared to conventional tryptic reaction schemes. In addition, the encapsulated trypsin exhibits increased stability even after continuous use. These features are required for high-throughput protein identification.  相似文献   

15.
Xiang Q  Hu G  Gao Y  Li D 《Biosensors & bioelectronics》2006,21(10):2006-2009
A portable heterogeneous immunoassay system is presented in this paper. It consists of a poly(dimethylsiloxane) (PDMS) based microfluidic chip as the immunoreactor, a miniaturized programmable high voltage sequencer as the power supply and the flow controller, and a laser-optical fiber fluorescence detection module as the signal reader. The operation of this immunoassay system is automatic. The sequential reagent dispensing and washing processes are controlled by the programmable sequencer. The reagent consumption was only 12 microL and the assay time was only 26 min. The detection limit for Escherichia coli O157:H7 bacterial antigen with this miniaturized system was 0.3 ng/muL, lower than that obtained using fluorescence microscope in previous studies.  相似文献   

16.
An immuno-culture method has been developed by combination of specific monoclonal antibodies and plate culture to allow detection of viable bifidobacteria. Cell wall proteins were selected as surface antigen to produce antibodies against bifidobacteria. The cell wall proteins were extracted and purified from six ATCC strains of bifidobacteria grown in MRS broth using an anaerobic system. To compare the profile of the protein extracts, all the protein solutions obtained were analyzed by SDS-PAGE. Similar bands corresponding to the major proteins of each species of bifidobacteria were observed. The proteins were tested for their immunogenicity in Balb/c mice after immunization and subsequent analysis using ELISA procedures. High immune responses were generated in mice immunized by proteins from Bifidobacterium bifidum and Bifidobacterium longum. Monoclonal antibodies were produced against B. longum and tested for their specificity, sensitivity and cross reactivity with other bifidobacteria species. All the hybridoma cells selected produced anti-B. longum antibodies cross-reacting with native and purified proteins from five other bifidobacteria species. An epitope supported by a cross-reacting protein of 58 kDa shared by bifidobacteria was revealed by western blot. This was confirmed by immune-transmission electron microscopy observations which showed the specific interaction of these antibodies with bifidobacterial cell wall proteins. Also, the antibody obtained was found to be specific for the genus Bifidobacterium and sensitive, allowing the detection of at least 10(5) target cells/ml. An immuno-culture detection approach was then developed using the selected anti-B. longum antibodies. This method was shown to be very efficient for the detection of viable cells of bifidobacteria suggesting the possibility of its use to quantify these bacteria in various food matrices.  相似文献   

17.
The present study reports a microfluidic system using the concept of membrane-movement to design and fabricate micro-pneumatic valves and pumps to form a bio-sensing diagnostic chip. The automatic bio-sampling system includes a micro-diagnostic chip fabricated by using MEMS (micro-electro-mechanical systems) technology and an automatic platform comprising of a control circuit, a compressed air source and several electromagnetic valve switches. The control circuit is used to regulate the electromagnetic valve switches, causing thin PDMS membranes to deflect pneumatically by the compressed air and generate valving and pumping effects. The micro-diagnostic chip allows for the quick detection of diseases. Compared to large-scale systems, the new microfluidic system uses smaller amounts of samples and reagents and performs fast diagnosis in an automated format. Instead of using traditional pneumatic micro-pumps, the current study adopts a new design called "spider-web" micro-pumps to increase the pumping rate, and more importantly, improve the uniformity of flow rates inside multiple micro-channels. Experimental data show that for disease diagnosis, the bio-sensing chips integrated with the micro-pneumatic valves and the peristaltic micro-pumps could successfully perform diagnosis tests. Small amounts of samples and reagents could be injected into the diagnosis chips using the micro-pumps and the micro-pneumatic valves could effectively control the movement of the samples and reagents. In order to demonstrate the functionality of the developed device, detection of hepatitis C virus (HCV) and syphilis has been performed using the bio-sampling chips. Experimental data show that fluorescence signals from the microfluidic system were comparable to the ones using conventional testing methods. The developed chip could be easily extended for multiple disease detection. The automatic bio-sensing chips could provide a useful tool for fast disease detection and be crucial for a micro-total-analysis system.  相似文献   

18.
聚合物微流控芯片成本低、易加工,目前在医药、生物检测和化学合成等领域得到了普遍应用。以热塑性聚合物聚甲基丙烯酸甲酯(polymethylmethacrylate,PMMA)和热固型聚合物聚二甲基硅氧烷(polydimethy lsiloxane,PDMS)为基材的高分子聚合物材料因具有较好的生物相容性和光学透明性,已逐渐成为聚合物微流控芯片加工的主导材料,被广泛应用于生物医药类微流控芯片的制备。鉴于该类芯片应用场景的特殊性,需在使用前进行消毒灭菌处理以避免微生物干扰。目前,针对PMMA和PDMS的消毒灭菌方法包括高压蒸汽灭菌、紫外线灭菌、电子束、60Co γ射线辐射灭菌、超临界二氧化碳灭菌、乙醇消毒、环氧乙烷灭菌、过氧化氢低温等离子体灭菌、绿原酸消毒、清洗剂消毒。本文从基本原理、消毒灭菌方法、应用场景等方面,回顾和总结了相关技术在PMMA和PDMS基体微流控芯片中的实现方法,并在芯片材质、适用范围等方面分析了所适用的消毒灭菌方法,为以聚合物为基材的生物医药类微流控芯片的消毒灭菌提供有益参考。  相似文献   

19.
We show a proof-of-concept in which we combine our previously published concepts of micromosaic immunoassays (microMIAs) with self-regulating microfluidic networks (microFNs) to detect C-reactive protein (CRP) and other cardiac markers such as myoglobin (Mb) and cardiac Troponin I (cTnI). The microFNs are microfabricated in Si, have a well-defined surface chemistry, and are affixed to a bibulous material so as to self-regulate the displacement of an aliquot of liquid through the microFNs using capillary forces. An open section of the channels of the microFNs is covered with a hydrophobic poly(dimethylsiloxane) (PDMS) slab that acts as the substrate for a solid-phase immunoassay. Here, individual assays are conducted using independent channels. These assays are "sequential": series of samples, reagents, and buffers are displaced one after the other over the PDMS surface, and, as these assays are conducted under "microfluidic" conditions, they are fast to perform, very economical in their use of reagents, extremely integrated, and yield high-quality signals. The combinatorial character of microMIAs is exploited to optimize the assay parameters for detecting CRP. In particular, we found it optimal to deposit the capture antibody for CRP on PDMS at a concentration between 20 and 500 microg ml(-1) in PBS in 1 min and to detect captured CRP in 2 min using a detection antibody having a concentration in PBS of 120 microg ml(-1). With this method, CRP is quantitatively detected within 10 min in one microliter of human plasma down to concentrations of 30 ng ml(-1), which suggests the possibility to detect CRP at clinically relevant concentrations for the management of coronary heart disease (CHD) and systemic inflammation.  相似文献   

20.
Conventional immunoassays are labor intensive, expensive and time consuming and require large pieces of equipment for detection. Therefore, we have developed and characterized a novel immunoassay methodology comprised of microbeads and microbiochips. In this method, microbeads are used to filter and immobilize antibodies and an immuno-gold silver staining (IGSS) method is then used to amplify electrical signals that correspond to the bound antibodies. The chip used for this system is composed of an inexpensive and biocompatible polydimethylsiloxane (PDMS) layer over a Pyrex glass substrate that contains a platinum (Pt) microelectrode, which is used to detect the electrical signal in this system, the microelectrode is fabricated on the substrate and a microchannel and pillar-type microfilter is formed in the PDMS layer. A sandwich immunoassay approach was applied to detect alpha-fetoprotein (AFP), a cancer biomarker, using this system. The results of this study showed that the time required for a complete assay was reduced by 1h and a detection limit as low as 1 ng/mL was attained when this system used, which indicates that similar bead-based electrical detection systems could be used for the diagnosis of many forms of cancer.  相似文献   