首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
This report evaluates the use of a quadrupolar ion trap for quantitation in a bioanalytical laboratory. The evaluation was accomplished with the cross-validation of an LC–MS–MS quantitative method previously validated on a triple quadrupole mass spectrometer. The method was a multi-level determination of the anti-obesity drug, orlistat, in human plasma. The method has been refined previously on a triple quadrupole instrument to provide rapid sample throughput with robust reproducibility at sub-nanogram detection limits. Optimization of the method on the ion trap required improved chromatographic separation of orlistat from interfering plasma matrix components coextracted during the initial liquid–liquid extraction of plasma samples. The ion trap produces full-scan collision-induced dissociation mass spectra containing characteristic orlistat fragment ions that are useful for quantitation. Data collection on the ion trap required a precursor ion isolation width of 3.0 Da and optimal quantitative results were obtained when three fragment ions were monitored with a 1.8 Da window for each ion. Although a direct cross-validation between the ion trap and the tandem triple quadrupole mass spectrometer was not possible, quantitative results for orlistat comparable to those obtained from the triple quadrupole instrument were achieved by the ion trap with the modified method. The limit of quantitation for orlistat in plasma on the ion trap was 0.3 ng ml−1 with a linear dynamic range of 0.3 to 10 ng ml−1. Precision and accuracy varied from 4 to 15% over the quantitation range. The overall results provide an example of the utility of an ion trap in bioanalytical work.  相似文献   

2.
The aim of the project was to develop a fast and reliable method for the quantification of the three tetracyclines: tetracycline, oxytetracycline and chlortetracycline in urine. The method is based on column-switching high-performance liquid chromatography with detection by MS–MS. Buffer is added to the sample before it is injected into the chromatographic system, and the first column which is an internal surface reversed-phase column separates the tetracyclines from the bulk of other compounds in urine. The tetracyclines are collected and concentrated on the analytical column before they are separated and eluted into the mass spectrometer in which the tetracycline are detected. The mass spectrometer is a triple quadrupole instrument and is equipped with an electrospray ion source. The MH+ ions are selected in the first quadrupole and collisionally activated in the collision cell. Upon collision, activation all three tetracyclines form fragment ions which could be assigned as: [M+H–H2O–NH3]+ which are selected in the sond mass filter. The detection limits for all three tetracyclines are about 10 ppb, and the calibration curves are linear from 10 to 1000 ppb.  相似文献   

3.
Introduction – Artemisinin, the primary active ingredient of the Chinese herb Artemisia annua L., is known to have considerable anti‐malaria properties. However, rapid, sensitive and selective method for the determination of artemisinin in it is not currently available. Objective – To develop and validate an efficient method for extraction and analysis of artemisinin from the plant samples of Artemisia annua L. by rapid resolution liquid chromatography triple quadrupole mass spectrometry (RRLC‐QQQ). Methodology – Following ultrasound‐assisted extraction (USE), RRLC‐QQQ was utilised to separate and determine artemisinin from the plant sample of Artemisia annua L. The LC separation, QQQ‐MS detection and multiple reaction monitoring (MRM) mode were optimised, and the method validation concluding selectivity, calibration, accuracy and precision, and recovery were also evaluated. Results – LC separation was performed with an isocratic elution of 20% of methanol–water (10 mmol/L ammonium acetate, pH 4.0) on a C18 column. The triple quadrupole MS detection was carried out under MRM mode of precursor ion [M + H]+ → fragment ions m/z 265.1 and m/z 247.2. The limits of detection and quantitation of artemisinin were 0.20 and 0.75 ng/mL, respectively. The intra‐ and inter‐day precisions did not exceed 3.71%, and the deviation of the intra‐ and inter‐day mean values did not exceed ±7.50. The average recoveries for artemisinin ranged from 92.45 to 103.8% with an RSD from 2.47 to 2.79%. Conclusion – The developed RRLC‐QQQ assay is an efficient method for separation and determination of artemisinin from the plant samples of Artemisia annua L. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
Methods based on high-performance liquid chromatography (HPLC) with atmospheric-pressure chemical ionization (APCI) mass spectrometric (MS) detection using either single (MS) or triple (MS/MS) quadrupole mass spectrometric detection for the determination of (2R)-[1(R)-(3,5-bis-trifluoromethylphenyl)ethoxy]-3(S)-(4-fluoro-phenyl)morpholin-4-ylmethyl]-5-oxo-4,5-dihydro-[1,2,4]triazol)methyl morpholine (Aprepitant, Fig. 1) in human plasma has been developed. Aprepitant (I) and internal standard (II, Fig. 1) were isolated from the plasma matrix buffered to pH 9.8 using a liquid-liquid extraction with methyl-t-butyl ether (MTBE). The analytes were separated on a Keystone Scientific's Javelin BDS C-8 2 mm x 4.6 mm 3 microm guard column coupled to BDS C-8 50 mm x 4.6 mm 3 microm analytical column, utilizing a mobile phase of 50% acetonitrile and 50% water containing 0.1% formic acid and 10 mM ammonium acetate delivered at a flow rate of 1 ml/min. The single quadrupole instrument was operated in a single ion monitoring (SIM) mode analyzing the protonated molecules of Aprepitant and II at m/z 535 and 503, respectively. The triple quadrupole mass spectrometer was operated in multiple reaction monitoring mode (MRM) monitoring the precursor --> ion combinations of m/z 535 --> 277 and 503 --> 259 for Aprepitant and II, respectively. The linear calibration range for both single and triple quadrupole detectors was from 10 to 5000 ng/ml of plasma with coefficients of variation less than 8% at all concentrations. Both single and triple quadrupole instruments yielded similar precision and accuracy results. Matrix effect experiments performed on both instruments demonstrated the absence of any significant change in ionization of the analytes when comparing neat standards to analytes in the presence of plasma matrix. Both instruments were used successfully to support numerous clinical trials of Aprepitant.  相似文献   

5.
Palytoxin analogs are marine toxins with large complex polyol structures. A benthic dinoflagellate Ostreopsis siamensis produces more than ten palytoxins (ostreocins, OSTs). The limited sample availability of minor OSTs restricts the definition of their chemical structures. The present investigation characterizes structures of two minor OSTs, i.e., ostreocin-A (OSTA) and ostreocin-E1 (OSTE1), using ostreocin-D (OSTD) as a reference compound, by liquid chromatography/quadrupole-time-of-flight mass spectrometry. The molecular formulas of OSTA and OSTE1 were C127H219N3O54 and C127H217N3O52, respectively. Compared to OSTD, OSTA has an extra oxygen atom whereas OSTE1 lacks one oxygen atom and two hydrogen atoms. The MS/MS experiments (precursor ions: [M + H]+ and [M-H]?) suggested a hydroxyl substitution at C82 in OSTA and alteration(s) between C53 and C100 in OSTE1. Further analysis of structural details in OSTE1 was performed through a pseudo-MS3 experiment (precursor ion: m/z 1432.748). Accordingly, the planar structures of OSTA and OSTE1 were assigned to 42,82-dihydroxy-3,26-didemethyl-19,44-dideoxypalytoxin and 42-hydroxy-3,26-didemethyl-19,44,73-trideoxypalytoxin-72-ene, respectively.

Abbreviations:CID: collision induced dissociation; HR-LC/MS/MS: high-resolution liquid chromatography/tandem mass spectrometry; LC/ESI/Q-TOF MS: liquid chromatography/quadrupole time-of-flight mass spectrometry equipped with an electrospray ionization source; NMR: nuclear magnetic resonance; OSTs: ostreocins; OSTA: ostreocin-A; OSTB: ostreocin-B; OSTD: ostreocin-D; OSTE1: ostreocin-E1; OVTX-a: ovatoxin-a; OVTXs: ovatoxins; PLTX: palytoxin  相似文献   


6.
A mass spectrometry method has been developed for selective detection of glycopeptides at the low (< or = 25) picomole level during chromatography of glycoprotein digests and for differentiation of O-linked from N-linked oligosaccharides. The technique involves observation of diagnostic sugar oxonium-ion fragments, particularly the HexNAc+ fragment at m/z 204, from collisionally excited glycopeptides. Collision-induced fragmentation can be accomplished in either of two regions of a triple quadrupole mass spectrometer equipped with an atmospheric pressure, electrospray (ES) ionization source. If collisions before the first quadrupole are chosen, it is possible to enhance formation of carbohydrate-related fragment ions without distorting the distribution of peptide and glycopeptide signals by increasing the collisional excitation potential only during that portion of each scan in which the low mass carbohydrate-related ions are being detected. This procedure, requiring only a single quadrupole instrument, identifies putative glycopeptide-containing fractions in the chromatogram but suffers from a lack of specificity in the case of co-eluting peptides. Increased specificity is obtained by selectively detecting only those parent ions that fragment in Q2, the second collision region of the triple quadrupole, to produce an ion at m/z 204 (HexNAc+). Only (M + H)+ ions of glycopeptides are observed in these liquid chromatography-electrospray tandem mass spectrometry (LC-ESMS/MS) "parent-scan" spectra. N-linked carbohydrates are differentiated from O-linked by LC-ESMS/MS analysis of the digested glycoprotein prior to and after selective removal of N-linked carbohydrates by peptide N:glycosidase F. These methods, which constitute the first liquid chromatography-mass spectrometry (LC-MS)-based strategies for selective identification of glycopeptides in complex mixtures, facilitate location and preparative fractionation of glycopeptides for further structural characterization. In addition, these techniques may be used to assess the compositional heterogeneity at specific attachment sites, and to define the sequence context of the attachment site in proteins of known sequence. The strategy is demonstrated for bovine fetuin, a 42-kDa glycoprotein containing three N-linked, and at least three O-linked carbohydrates. Over 90% of the fetuin protein sequence was also corroborated by these LC-ESMS studies.  相似文献   

7.
Yu SY  Wu SW  Khoo KH 《Glycoconjugate journal》2006,23(5-6):355-369
Concerted MALDI-MS profiling and CID MS/MS sequencing of permethylated glycans is one of the most effective approaches for high throughput glycomics applications. In essence, the identification of larger complex type N-glycans necessitates an unambiguous definition of any modification on the trimannosyl core and the complement of non-reducing terminal sequences which constitute the respective antennary structures. Permethylation not only affords analyses of both neutral and sialylated glycans at comparable ease and sensitivity but also yields more sequence-informative fragmentation pattern. Facile glycosidic cleavages directed mostly at N-acetylglucosamine under low energy CID, as implemented on a quadrupole/time-of-flight (Q/TOF) instrument, often afford multiple losses of the attached antenna resulting in characteristic ions related to the number of antennary branches on the trimannosyl core. Non-reducing terminal epitopes can be easily deduced but information on the linkage specific substituent on the terminal units is often missing. The high energy CID MS/MS afforded by TOF/TOF instrument can fill in the gap by giving an array of additional cross-ring and satellite ions. Glycosidic cleavages occurring specifically in concert with loss of 2-linked or 3-linked substituents provide an effective way to identify the branch-specific antennary extension. These characteristics are shown here to be effective in deriving the sequences of additionally galactosylated, sialylated and fucosylated terminal N-acetyllactosamine units and their antennary location. Together, a highly reproducible fragmentation pattern can be formulated to simplify spectral assignment. This work also provides first real examples of sequencing multiply sialylated complex type N-glycans by high energy CID on a TOF/TOF instrument. Shin-Yi Yu and Sz-Wei Wu contributed equally to this work. Dedicated to the late Prof. Yasuo Inoue, without whom the body of work represented by this article would not have been initiated in Taiwan.  相似文献   

8.
We describe the design and performance of a prototype high performance hybrid mass spectrometer. This instrument consists of a linear quadrupole ion trap (QLT) coupled to a Fourier transform ion cyclotron resonance mass analyzer (FTMS). This configuration provides rapid and automated MS and MS/MS analyses, similar to the "data dependent scanning" found on standard 3-D Paul traps, but with substantially improved internal scan dynamic range, mass measurement accuracy, mass resolution, and detection limits. Sequence analysis of peptides at the zeptomole level is described. The recently released, commercial version of this instrument operates in the LC/MS mode (1 s/scan) with a mass resolution of 100 000 and is equipped with automatic gain control to provide mass measurement accuracy of 1-2 ppm without internal standard. Methodology is described that uses this instrument to compare the post-translational modifications present on histone H3 isolated from asynchronously growing cells and cells arrested in mitosis.  相似文献   

9.
Mass spectrometry-based proteomics has greatly benefitted from enormous advances in high resolution instrumentation in recent years. In particular, the combination of a linear ion trap with the Orbitrap analyzer has proven to be a popular instrument configuration. Complementing this hybrid trap-trap instrument, as well as the standalone Orbitrap analyzer termed Exactive, we here present coupling of a quadrupole mass filter to an Orbitrap analyzer. This "Q Exactive" instrument features high ion currents because of an S-lens, and fast high-energy collision-induced dissociation peptide fragmentation because of parallel filling and detection modes. The image current from the detector is processed by an "enhanced Fourier Transformation" algorithm, doubling mass spectrometric resolution. Together with almost instantaneous isolation and fragmentation, the instrument achieves overall cycle times of 1 s for a top 10 higher energy collisional dissociation method. More than 2500 proteins can be identified in standard 90-min gradients of tryptic digests of mammalian cell lysate- a significant improvement over previous Orbitrap mass spectrometers. Furthermore, the quadrupole Orbitrap analyzer combination enables multiplexed operation at the MS and tandem MS levels. This is demonstrated in a multiplexed single ion monitoring mode, in which the quadrupole rapidly switches among different narrow mass ranges that are analyzed in a single composite MS spectrum. Similarly, the quadrupole allows fragmentation of different precursor masses in rapid succession, followed by joint analysis of the higher energy collisional dissociation fragment ions in the Orbitrap analyzer. High performance in a robust benchtop format together with the ability to perform complex multiplexed scan modes make the Q Exactive an exciting new instrument for the proteomics and general analytical communities.  相似文献   

10.
A liquid chromatography (LC)/electrospray ionization (ESI)-mass spectrometry (MS) method for the direct determination of eighteen tetrahydrocorticosteroid sulfates in human urine has been developed. The analytes were 3- and 21-monosulfates and 3,21-disulfates of tetrahydrocortisol (THF), tetrahydrocortisone (THE), tetrahydro-11-deoxycortisol (THS), and their corresponding 5α-H stereoisomers. The mass spectrometric behavior of these sulfates in negative-ion ESI-MS/MS revealed the production of intense structure specific product ions within the same group of sulfates and permitted distinction between regioisomeric sulfates by collision-induced fragmentation with the MS/MS technique using a linear ion-trap instrument. For the quantitative analysis, selected reaction monitoring analysis in the negative-ion detection mode using triple-stage quadrupole mass spectrometer was performed by monitoring transitions from [M−H] to the most abundant product ion of each tetrahydrocorticosteroid sulfate. After addition of 3- and 21-monosulfates of [2,2,3β,4,4-d5]-THF, -THE, and -THS as internal standards, urine sample was applied to a solid phase extraction using a lipophilic-weak anion exchange cartridge column, and then analyzed by LC/ESI-MS/MS. The method had satisfactory performance in terms of intra- and inter-assay precision (less than 9.7% and 9.6%, respectively), and accuracy (91.2–108.2%). The limit of quantification was lower than 2.5 ng/mL for all sulfates examined. We applied this method to determine the concentration of eighteen tetrahydrocorticosteroid sulfates in the urine of healthy subjects. Thus, we have developed a sensitive, precise and accurate assay for urinary tetrahydrocorticosteroid sulfates that should be useful for clinical and biological studies.  相似文献   

11.
Proteomics is gradually complementing large shotgun qualitative studies with hypothesis-driven quantitative experiments. Targeted analyses performed on triple quadrupole instruments in selected reaction monitoring mode are characterized by a high degree of selectivity and low limit of detection; however, the concurrent analysis of multiple analytes occurs at the expense of sensitivity because of reduced dwell time and/or selectivity due to limitation to a few transitions. A new data acquisition paradigm is presented in which selected reaction monitoring is performed in two ways to simultaneously quantify and confirm the identity of the targeted peptides. A first set of primary transitions is continuously monitored during a predetermined elution time window to precisely quantify each peptide. In addition, a set of six to eight transitions is acquired in a data-dependent event, triggered when all the primary transitions exceed a preset threshold. These additional transitions are used to generate composite tandem mass spectra to formally confirm the identity of the targeted peptides. This technique was applied to analyze the tryptic digest of a yeast lysate to demonstrate the performance of the technique. We showed a limit of detection down to tens of attomoles injected and a throughput exceeding 6000 transitions in one 60-min experiment. The technique was integrated into a linear work flow, including experimental design, data acquisition, and data evaluation, enabling large scale proteomic studies.Proteomics is gradually complementing qualitative studies focused on protein identification relying on shotgun strategies (1, 2) with large scale quantitative experiments. This change was prompted by the growing demand for qualification and verification of putative protein biomarkers through analysis of larger cohorts of clinical samples on one hand and the need for consistent quantitative data sets to facilitate modeling in systems biology studies on the other. In either case, the number of proteins under target is quite large (tens to hundreds), and traditional immunoassay approaches are not suited for use because of the cost, time, and difficulty of developing multiplexed assays. In this context, the selected reaction monitoring (SRM)1 technique performed on a triple quadrupole mass spectrometer is increasingly applied to quantitative proteomics because of its sensitivity, selectivity, and wide dynamic range (36). Mass spectrometry assays can be developed very rapidly via the use of commodity synthetic reference peptides libraries (7), and large resources of peptide MS/MS data (MRMAtlas) (8) are available to design the initial assays. However, developing a robust and precise SRM-based multiple assay remains demanding for proteomics experiments.One of the main challenges is that most proteomics samples are highly complex, and several interfering signals are detected within a given time window that require systematic verification of the target peptide identity first to ensure its accurate quantification. Using isotopically labeled counterparts of the targeted analytes is a common way to confirm the target peptide identity (9, 10). As this may not always be practical for large scale quantitative proteomics studies, an alternative way to verify the peptide identity is to use SRM-initiated full MS/MS scans (11). However, the disadvantage of this method is a lower sensitivity and selectivity compared with SRM as it uses a broader mass selection window, which results in MS/MS spectra often containing signals from multiple components co-eluting in the case of biological samples with a complex background. Furthermore, SRM-initiated MS/MS scans require much longer duty cycle times that will disrupt the predefined SRM sequence of events in the case of complex multiplexed assays even when performed on a triple quadrupole instrument equipped with a linear ion trap. Recently, instead of using MS/MS spectra, a composite MS/MS spectrum that is generated by measuring multiple fragments ions (8–10 ions) from one specific peptide has been proven to provide sufficient information for peptide identification.2 The peptide is verified both by the overlay of the chromatographic elution profiles of the fragment ions and by matching the composite MS/MS spectrum that comprises multiple SRM transitions to the MS/MS spectral library entry (12, 13). Because it is based on SRM acquisition, this method provides a rapid, sensitive, and selective way to perform peptide verification, which is desirable for large scale screening experiments. The drawback of this approach is that only a limited number of compounds can be practically analyzed in one HPLC-MS run because the instrument is continuously monitoring 8–10 transitions for each peptide no matter whether the peptide is detected from the sample or not, resulting in the waste of a significant portion of the instrument time. To overcome this issue and thus increase the throughput, we propose that the instrument constantly monitor only a small subset of SRM transitions for each peptide for the actual quantification and in addition confirm the peak identity using the full set of fragment ions, which are acquired in a data-dependent mode.To provide this instrument capability, we developed an innovative instrument control software, called intelligent selected reaction monitoring (iSRM), that can use the specificity of a small subset of SRM transitions to quantify and intelligently trigger the full list for confirmation of target peptides, thereby allowing the simultaneous qualitative and quantitative analysis of up to 1000 peptides in a single LC-MS experiment. Here we describe the concept of iSRM and the work flow associated to it, and we demonstrate the increased throughput facilitating the development of SRM assays and its ability to perform large scale screens targeting a respectable number of proteins.  相似文献   

12.
This study is the first report of applying an ultra high performance liquid chromatography/tandem mass spectrometric (UHPLC-MS/MS) multi-mycotoxin method to identify and quantify the mycotoxins produced by pure fungal isolates grown on Yeast Extract Sucrose (YES) agar. The method developed concerns a triple extraction procedure based on methanol, dichloromethane and ethyl acetate. The total extract was chromatographically separated on an UHPLC BEH C18 column and analyzed with a triple quadrupole mass spectrometer. Performance characteristics (specificity, linearity, possible matrix effects, recovery, repeatability, reproducibility and limit of detection) were evaluated by spiking experiments with blank agar plugs and the analytes. Verrucarol was used as internal standard. Recovery percentages varied between 56 and 125%, whereas the limit of detection ranged from 1 to 1,500 ng g−1 with the exception of NIV, PAT and ZEA. The method was successfully applied for examining the in vitro mycotoxin production by Aspergillus fumigatus, A. flavus and A. niger. The mobile phases used for chromatographic separation were slightly modified when studying patulin-producing molds due to signal interference between this mycotoxin and an unknown metabolite. This modified method was successfully applied for Penicillium roqueforti, P. paneum and P. carneum grown on YES agar medium. Application of the multi-mycotoxin UHPLC-MS/MS method developed may be of great importance for studying the mycotoxin capacity of fungal isolates under varying growth conditions, in order to obtain a better insight into the conditions which induce or suppress mycotoxin production by pure fungal isolates or from a chemotaxonomic point of view.  相似文献   

13.
Protein oxidation is thought to contribute to a number of inflammatory diseases, hence the development of sensitive and specific analytical techniques to detect oxidative PTMs (oxPTMs) in biological samples is highly desirable. Precursor ion scanning for fragment ions of oxidized amino acid residues was investigated as a label‐free MS approach to mapping specific oxPTMs in a complex mixture of proteins. Using HOCl‐oxidized lysozyme as a model system, it was found that the immonium ions of oxidized tyrosine and tryptophan formed in MS2 analysis could not be used as diagnostic ions, owing to the occurrence of isobaric fragment ions from unmodified peptides. Using a double quadrupole linear ion trap mass spectrometer, precursor ion scanning was combined with detection of MS3 fragment ions from the immonium ions and collisionally‐activated decomposition peptide sequencing to achieve selectivity for the oxPTMs. For chlorotyrosine, the immonium ion at 170.1 m/z fragmented to yield diagnostic ions at 153.1, 134.1, and 125.1 m/z, and the hydroxytyrosine immonium ion at 152.1 m/z gave diagnostic ions at 135.1 and 107.1 m/z. Selective MS3 fragment ions were also identified for 2‐hydroxytryptophan and 5‐hydroxytryptophan. The method was used successfully to map these oxPTMs in a mixture of nine proteins that had been treated with HOCl, thereby demonstrating its potential for application to complex biological samples.  相似文献   

14.
Biosurfactant-producing bacteria were isolated from the production water of an oil field. Isolates were screened for biosurfactant production using surface tension test. The highest reduction of surface tension was achieved with a bacterial strain which was identified by 16S rRNA gene sequencing as Brevibacilis brevis HOB1. It has been investigated using different carbon and nitrogen sources. It showed that the strain was able to grow and reduce the surface tension of the broth to 29 mN/m on commercial sugar and maltose, and to 32 mN/m on glucose after 72 h of growth. The maximum amount of biosurfactant was obtained when nitrate ions were supplied as nitrogen source. Biosurfactant produced by Brevibacilis brevis HOB1 was confirmed as a lipopeptide class of biosurfactant using TLC test and mass spectra. Lipopeptide isoforms were isolated from cell-free supernatants by acid-precipitation followed by one step of chromatographic separation on solid-phase ODS C18 column. The separation was confirmed by HPLC and ESI Q-TOF MS spectroscopy. Comparing the mass data obtained and the mass numbers reported for the lipopeptide complexes from other strains, it can be concluded that the major lipopeptide product of Brevibacilis brevis HOB1 is the surfactin isoform. This lipopeptide showed strong antibacterial and antifungal activity. It is a candidate for the biocontrol of pathogens in agriculture and other industries.  相似文献   

15.
Introduction: Advances in mass spectrometry (MS)-based proteomic strategies have resulted in robust protein biomarker discovery studies often performed on high resolution accurate mass (HRAM) platforms. For successful translation of promising protein biomarkers into useful clinical tests, trans-sector networks and collaboration among stakeholders involved in the biomarker pipeline are urgently needed.

Areas covered: In this perspective, literature- and empirical evidence is combined with author’s opinions to discuss the progress of ultrahigh resolution MS and provide insight in its potential for validation and development of clinical tests.

Expert commentary: Thus far two ‘low resolution’ MS strategies have been implemented in the clinic: quantification of proteins using triple quadrupole instruments and identification of unknown microorganisms using comparative analysis with spectral libraries on MALDI-TOF instruments. The rise of HRAM technology further boosts the potential of MS-based tests for detection and quantitation of disease-specific biomarkers which meet the analytical performance specifications needed for clinical assays.  相似文献   


16.
The usability of a quadrupole—quadrupole—time‐of‐flight (QqTOF) instrument for the tandem mass spectrometric sequencing of oligodeoxynuleotides was investigated. The sample set consisted of 21 synthetic oligodeoxynucleotides ranging in length from 5 to 42 nucleotides. The sequences were randomly selected. For the majority of tested oligonucleotides, two or three different charge states were selected as precursor ions. Each precursor ion was fragmented applying several different collision voltages. Overall 282 fragment ion mass spectra were acquired. Computer‐aided interpretation of fragment ion mass spectra was accomplished with a recently introduced comparative sequencing algorithm (COMPAS). The applied version of COMPAS was specifically optimized for the interpretation of information‐rich spectra obtained on the QqTOF. Sequences of oligodeoxynucleotides as large as 26‐mers were correctly verified in >94% of cases (182 of 192 spectra acquired). Fragment ion mass spectra of larger oligonucleotides were not specific enough for sequencing. Because of the occurrence of extensive internal fragmentation causing low sequence coverage paired with a high probability of assigning fragment ions to wrong sequences, tandem mass spectra obtained from oligonucleotides consisting of 30 and more nucleotides could not be used for sequence verification neither manually nor with COMPAS. © 2009 Wiley Periodicals, Inc. Biopolymers 91: 401–409, 2009. This article was originally published online as an accepted preprint. The “Published Online” date corresponds to the preprint version. You can request a copy of the preprint by emailing the Biopolymers editorial office at biopolymers@wiley.com  相似文献   

17.
Zhao YY  Cheng XL  Wei F  Xiao XY  Sun WJ  Zhang Y  Lin RC 《Biomarkers》2012,17(1):48-55
An ultra performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (UPLC Q-TOF MS) metabonomics approach was employed to study the serum metabolic profiling of adenine-induced chronic renal failure (CRF) rats. Acquired data were subjected to principal component analysis (PCA) for differentiating the CRF and the normal control groups. Potential biomarkers were screened by using S-plot and were identified by the accurate mass, isotopic pattern and MS/MS fragments information obtained from UPLC Q-TOF MS analysis. Significant differences in the serum level of creatinine, amino acids and LysoPCs were observed, indicating the perturbations of amino acid metabolism and phospholipid metabolism in adenine-induced CRF rats. This research proved that metabonomics is a promising tool for disease research.  相似文献   

18.
Profiling of plant secondary metabolites is still a very difficult task. Liquid chromatography (LC) or capillary electrophoresis hyphenated with different kinds of detectors are methods of choice for analysis of polar, thermo labile compounds with high molecular masses. We demonstrate the applicability of LC combined with UV diode array or/and mass spectrometric detectors for the unambiguous identification and quantification of flavonoid conjugates isolated from Arabidopsis thaliana leaves of different genotypes and grown in different environmental conditions. During LC/UV/MS/MS analyses we were able to identify tetra-, tri-, and di-glycosides of kaempferol, quercetin and isorhamnetin. Based on our results we can conclude that due to the co-elution of different chemical compounds in reversed phase HPLC systems the application of UV detectors does not allow to precisely profile all flavonoid conjugates existing in A. thaliana genotypes. Using MS detection it was possible to unambiguously recognize the glycosylation patterns of the aglycones. However, from the mass spectra we could not conclude neither the anomeric form of the C-1 carbon atoms of sugar moieties in glycosidic bonds between sugars or sugar and aglycone nor the position of the second carbon involved in disaccharides. The applicability of collision induced dissociation techniques (CID MS/MS) for structural analyses of the studied group of plant secondary metabolites with two types of analyzers (triple quadrupole or ion trap) was demonstrated.  相似文献   

19.
We recently described an isotope dilution reversed-phase liquid chromatography-atmospheric pressure chemical ionization-ion-trap-tandem mass spectrometry (HPLC-APCI-MS/MS) method for the quantitative determination of oxidized amino acids in human urine, including o,o'-dityrosine, a specific marker of protein oxidation. In the present study, we investigated the possibility to use a triple quadrupole instrument for the analysis of this biomarker in urine. The two instruments were compared in terms of sensitivity, specificity and reproducibility. Results showed that the triple quadrupole instrument reaches 2.5-fold higher sensitivity (LOD=0.01 microM) compared to the previously used ion-trap instrument. Precision of the present assay is as follows: in-day variation is 4.6% and inter-day variation is 17%. The currently developed method was applied to a group of smoker urine samples. The mean urinary o,o'-dityrosine concentration was 0.08+/-0.01 microM. Expressed per urinary creatinine concentration, this corresponds to 10.1+/-0.4 micromol/mol creatinine. This is comparable to the previously reported values of 5.8+/-0.3 micromol/mol creatinine in non-smokers night-time urines, and 12.3+/-5 micromol/mol creatinine in day-time urines measured by the ion-trap instrument.  相似文献   

20.
There is an immediate need for improved methods to systematically and precisely quantify large sets of peptides in complex biological samples. To date protein quantification in biological samples has been routinely performed on triple quadrupole instruments operated in selected reaction monitoring mode (SRM), and two major challenges remain. Firstly, the number of peptides to be included in one survey experiment needs to be increased to routinely reach several hundreds, and secondly, the degree of selectivity should be improved so as to reliably discriminate the targeted analytes from background interferences. High resolution and accurate mass (HR/AM) analysis on the recently developed Q-Exactive mass spectrometer can potentially address these issues. This instrument presents a unique configuration: it is constituted of an orbitrap mass analyzer equipped with a quadrupole mass filter as the front-end for precursor ion mass selection. This configuration enables new quantitative methods based on HR/AM measurements, including targeted analysis in MS mode (single ion monitoring) and in MS/MS mode (parallel reaction monitoring). The ability of the quadrupole to select a restricted m/z range allows one to overcome the dynamic range limitations associated with trapping devices, and the MS/MS mode provides an additional stage of selectivity. When applied to targeted protein quantification in urine samples and benchmarked with the reference SRM technique, the quadrupole-orbitrap instrument exhibits similar or better performance in terms of selectivity, dynamic range, and sensitivity. This high performance is further enhanced by leveraging the multiplexing capability of the instrument to design novel acquisition methods and apply them to large targeted proteomic studies for the first time, as demonstrated on 770 tryptic yeast peptides analyzed in one 60-min experiment. The increased quality of quadrupole-orbitrap data has the potential to improve existing protein quantification methods in complex samples and address the pressing demand of systems biology or biomarker evaluation studies.Shotgun proteomics has emerged over the past decade as the most effective method for the qualitative study of complex proteomes (i.e., the identification of the protein content), as illustrated by a wealth of publications (1, 2). In this approach, after enzymatic digestion of the proteins, the generated peptides are analyzed by means of liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS)1 in a data dependent mode. However, the complexity of the digested proteomes under investigation and the wide range of protein abundances limit the reproducibility and the sensitivity of this stochastic approach (3), which is critical if one aims at the systematic quantification of the proteins. Thus, alternative MS approaches have emerged for the systematic quantitative study of complex proteomes, the MS-based targeted proteomics (4). In this hypothesis-driven approach, only specific subsets of analytes (a few targeted peptides used as surrogates for the proteins of interest) are selectively measured in predefined m/z ranges and retention time windows, which overcomes the bias toward most abundant compounds commonly observed with shotgun proteomics. When applied to complex biological samples—for example, bodily fluids such as urine or plasma—targeted proteomics requires high performance instruments allowing measurements of a wide dynamic range (many orders of magnitude), with high sensitivity in order to detect peptides in the low amol range and sufficient selectivity to cope with massive biochemical background (5). Selected reaction monitoring (SRM) on triple quadrupole (6) or triple quadrupole-linear ion trap mass spectrometers (7) has emerged as a means to conduct such analyses (8). Initially applied in the MS analysis of small molecules (9, 10), SRM has gradually emerged as the reference quantitative technique for analyzing proteins (or peptides) in biological samples. When coupled with the isotope dilution strategy (11, 12), this very effective technique allows the precise quantification of proteins (1318). However, despite the increased selectivity provided by the two-stage mass filtering of SRM (at the precursor and fragment ion levels), the low resolution of mass selection does not allow the systematic removal of interferences (19, 20). Moreover, in proteomics, the biochemical background has a composition similar to that of the analytes of interest, which remains a major hurdle limiting the sensitivity of assays, especially in a bodily fluid matrix. High resolution/accurate mass (HR/AM) analysis represents a promising alternative approach that might more efficiently distinguish the compounds of interest from interferences in targeted proteomics. Such analyses can be conducted on orbitrap-based mass spectrometers because of their high sensitivity and high mass accuracy capabilities (21). The introduction of the benchtop standalone orbitrap mass spectrometer (Exactive) (22) further strengthened the attractiveness of the approach, especially in the field of small molecule analysis (23, 24). However, as quantification using trapping devices intrinsically suffers from a limited dynamic range because of the overall ion capacity, the complexity of biological samples remains very challenging even with the HR/AM approach (25). Targeted protein analysis with triple quadrupole mass spectrometers keeps on showing significant superiority for such samples.2 The recently developed quadrupole-orbitrap mass spectrometer (Q-Exactive) can potentially address this issue.3 It is constituted of an orbitrap mass analyzer equipped with a quadrupole mass filter as the front-end for precursor ion mass selection (26, 27). This configuration combines advantages of triple quadrupole instruments for mass filtering and orbitrap-based mass spectrometers for HR/AM measurement. The ability of the instrument to select a restricted m/z range or (sequentially) a small number of precursor ions offers new opportunities for quantification in complex samples by selectively enriching low abundant components. The resulting data, acquired in the so-called single ion monitoring (SIM) mode, fully benefit from the trapping capability while keeping a high acquisition rate as a result of the fast switching time between targeted precursor ions of the quadrupole. Although this mode of data acquisition is possible with a configuration combining a linear ion trap with the orbitrap (as in the LTQ-Orbitrap mass spectrometer), its effectiveness is far more limited in this case. The quadrupole-orbitrap configuration presents significant benefits by selectively isolating a narrow population of precursor ions. Other features of the instrument include its multiplexed trapping capability (26) using either the C-trap or the higher energy collisional dissociation (HCD) cell (28, 29), which opens new avenues in the design of innovative acquisition methods for quantification studies. For the first time, a panel of acquisition methods is designed and applied to targeted quantification at the MS and MS/MS levels. In the latter case, the simultaneous monitoring of multiple MS/MS fragmentation channels, also called parallel reaction monitoring4 (PRM), is particularly promising for quantifying large sets of peptides with increased selectivity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号