 共查询到20条相似文献,搜索用时 15 毫秒
1.
Intravascular brachytherapy (IVB) to prevent restenosis is currently being performed using several different commercial delivery devices. The Novoste Beta-Cath system uses a source train of 90Sr/90Y pure beta emitters and two gold radiopaque markers. A nonactive transfer device with dummy sources is also supplied to test the delivery catheter. We have developed an alternate procedure using an acrylic shield to test both the active transfer device and delivery catheter prior to patient treatment.  相似文献   

2.
3.
Purpose: Both β and γ sources of fixed length are currently used in the catheter-based intravascular brachytherapy (IVBT). Source stepping is often used to treat a lesion longer than the effective treatment length of the source. A major challenge for the stepping procedure is to attain a perfect dosimetric match (uniform dose) at the source junction. This work presents a quantitative and systematic dosimetric analysis for source stepping during an IVBT procedure. Materials and Methods: The three most commonly used β and γ sources (192Ir by BEST, 90Sr by NOVOSTE and 32P by Guidant) were studied using the EGSnrc Monte Carlo code. Dose distributions were calculated for a perfect end-to-end match and for a range of end-to-end gaps and overlaps between consecutive steps. Results: It is found that a perfect end-to-end match during source stepping yields uniform dose distribution in the region of source junction. The doses in the case of a mismatch (in the presence of an end-to-end gap or overlap) were found to be significantly different from those with the perfect end-to-end match. The dose deviation depends on the size of the gap or overlap, radial distance and type of source. The dose deviation decreases with radial distance for a given gap/overlap. For example, for a gap/overlap of 2 mm, dose decreases/increases of 30%, 55% and 60% were found at the radial distance of 2 mm from source for 192Ir, 90Sr and 32P, respectively. These dose deviations are reduced by approximately 10% when the radial distance increases from 2 to 3 mm. The dose deviations for gaps or overlaps in the range of 0–5 mm are presented. Conclusions: During an IVBT procedure involving source stepping, a perfect end-to-end match is always desired. Significant underdosing or overdosing can occur in the case of a source mismatch. A considerable caution should be exercised to ensure that sources are properly matched.  相似文献   

4.
Monte Carlo calculations are highly spread and settled practice to calculate brachytherapy sources dosimetric parameters. In this study, recommendations of the AAPM TG-43U1 report have been followed to characterize the Varisource VS2000 192Ir high dose rate source, provided by Varian Oncology Systems.In order to obtain dosimetric parameters for this source, Monte Carlo calculations with PENELOPE code have been carried out. TG-43 formalism parameters have been presented, i.e., air kerma strength, dose rate constant, radial dose function and anisotropy function. Besides, a 2D Cartesian coordinates dose rate in water table has been calculated. These quantities are compared to this source reference data, finding results in good agreement with them.The data in the present study complement published data in the next aspects: (i) TG-43U1 recommendations are followed regarding to phantom ambient conditions and to uncertainty analysis, including statistical (type A) and systematic (type B) contributions; (ii) PENELOPE code is benchmarked for this source; (iii) Monte Carlo calculation methodology differs from that usually published in the way to estimate absorbed dose, leaving out the track-length estimator; (iv) the results of the present work comply with the most recent AAPM and ESTRO physics committee recommendations about Monte Carlo techniques, in regards to dose rate uncertainty values and established differences between our results and reference data.The results stated in this paper provide a complete parameter collection, which can be used for dosimetric calculations as well as a means of comparison with other datasets from this source.  相似文献   

5.
Cobalt 60 source is generally available on high dose rate (HDR) afterloading equipment especially for treatment of gynecological lesions. The GZP6 remote afterloader (Nuclear Power Institute of China) utilizes 60Co sources for treatment of intracavitary and intraluminal malignancies. In this study, the AAPM TG-43 dosimetric parameters of three sources in GZP6 system have been studied using MCNP4C Monte Carlo (MC) code; and the results are compared with other available 60Co HDR sources. The presented parameters consist of air kerma strength, dose rate constant, radial dose function and anisotropy function. They show less than 1% uncertainty. The TG-43 based dosimetry data can be used not only to validate the dedicated treatment planning software (TPS), but also to introduce new complementary software to enhance the system performance in gynecological treatments.  相似文献   

6.
Late radiation-induced changes in pig skin have been assessed following irradiation with beta-rays from a 22.5- or 15-mm-diameter 90Sr/90Y source and a 19- or 9-mm-diameter 170Tm source. Late damage, in terms of dermal atrophy, was assessed 2 years after irradiation from measurements of dermal thickness in irradiated and normal skin. After 90Sr irradiation maximum atrophy, a dermal thickness of 40-50% of the control value, occurred at a dose of approximately 40 Gy from the 22.5-mm source and approximately 75 Gy from the 15-mm source. In the case of 170Tm the 19- and 9-mm sources produced similar degrees of atrophy at equal doses. Maximum atrophy occurred at approximately 70 Gy, when the dermis was approximately 70% of the thickness of normal skin. Significant late tissue atrophy was seen at doses, from both types of radiation, which only produced minimal erythema in the early reaction. Such late reactions need to be taken into account when revised radiological protection criteria are proposed for skin.  相似文献   

7.
Purpose: In catheter-based intravascular brachytherapy, either photon or beta emitters are often used in a linear arrangement so that blood vessels of 10-30 mm lengths can be treated. With a line source, the dose gradient in the radial direction and longitudinal direction depend on the type of radionuclides used in the treatment. The purpose of this study was to investigate the dose fall-off at the edges of a linear source in a blood vessel for different types of photon and beta emitters.Materials/Methods: Dose distributions were calculated on cylindrical blood vessels of various radii. Radioactive sources of 192Ir, 125I, 103Pd, 188Re, 32P, and 90Y/Sr were studied. All the sources were assumed to be in the form of a line. The dose rate at a point in space produced by a radioactive source was computed by integrating the point dose rate kernel of the corresponding radionuclide over the radioactive line. The point dose rate kernel was computed with Monte Carlo simulation of radiation transport. The edge effects were characterized with three newly defined quantities: longitudinal dose uniformity (LDU), effective coverage length (ECL), and margin length (ML). LDU was defined as the ratio of dose at a distance along the long axis of the vessel to the dose at center. ECL was defined as the length over which the LDU was greater than 0.95. ML was defined as half of the length difference between source length L and ECL, which is essentially the length segment at each edge that is covered by the source physical length but is being underdosed.Results: All beta emitters provided more uniform dose distributions and covered a larger portion of blood vessels longitudinally than photon emitters. Typical MLs were 2-3 mm for beta emitters and 4-6 mm for gamma emitters. As the radial depth of the point of interest increased, both the LDU and ECL decreased and ML increased. The ML increased from 2 to 3 mm for beta emitters and from 4 to 6 mm for photon emitters when the radial depth of the point of interest increased from 1.5 to 2.5 mm (typical proximal and distal media points for a 3-mm diameter lumen). The ML increased with increasing source length for all radionuclides. For beta emitters the ML increased initially from 1.5 mm to more than 2.5 mm as source length increased from 5 to 10 mm. When the source length was longer than 15 mm, the ML remains nearly constant, about 3 mm. For photon emitters, ML increased continuously from 1.5 mm to more than 6.0 mm, as source length increased from 5 to 50 mm.Conclusions: A formalism to quantify the dose uniformity along the length of a blood vessel undergoing catheter-based intravascular brachytherapy has been developed. This formalism was used to study the edge effects at the ends of several beta and photon sources. The results indicated that for a centered source the ML at each end due to penumbra effects was about 2 to 3 mm for beta emitters; about 4-6 mm for photon emitters. The ML increases as the radial depth of point of interest in the vessel increases. The ML increases also with increasing source length, especially for photon sources.  相似文献   

8.
Circular areas of pig skin from 1- to 40-mm diameter were irradiated with beta emitters of high, medium, and low energies, 90Sr, 170Tm, and 147Pm, respectively. The study provides information for radiological protection problems of localized skin exposures. During the first 16 weeks after irradiation 90Sr produced a first reaction due to epithelial cell death followed by a second reaction attributable to damage to the dermal blood vessels. 170Tm and 147Pm produced the epithelial reaction only. The epithelial dose response varied as a function of beta energy. The doses required to produce moist desquamation in 50% of 15- to 22.5-mm fields (ED50) were 30-45 Gy from 90Sr, approximately 80 Gy from 170Tm, and approximately 500 Gy from 147Pm. A model involving different methods of epithelial repopulation is proposed to explain this finding. An area effect was observed in the epithelial response to 90Sr irradiation. The ED50 for moist desquamation ranged from approximately 25 Gy for a 40-mm source to approximately 450 Gy for a 1-mm source. The 5-, 9-, and 19-mm 170Tm sources all produced an ED50 of approximately 80 Gy, while the value for the 2-mm source was approximately 250 Gy. It is also suggested that the area effects could be explained by different modes of epithelial repopulation after irradiation. After high energy beta irradiation repopulation would be mainly from the field periphery, while after lower energy irradiation repopulation from hair follicle epithelium would predominate.  相似文献   

9.
Purpose: The use of endovascular coronary brachytherapy to prevent restenosis following percutaneous transluminal coronary angioplasty (PTCA) began in April 1997 at the Department of Interventional Cardiology of the Thoraxcenter at the University Hospital of Rotterdam. This article reviews the more than 250 patients that have been treated so far.Methods and Materials: The Beta-Cath System (Novoste), a manual, hydraulic afterloader with 12 90Sr seeds, was used in the Beta Energy Restenosis Trial (BERT-1.5, n=31), for compassionate use (n=25), in the Beta-Cath System trial (n=27) and in the Beta Radiation in Europe (BRIE, n=14). Since the Beta-Cath System has been commercialized in Europe, 57 patients have been treated and registered in RENO (Registry Novoste). In the Proliferation Reduction with Vascular Energy Trial (PREVENT), 37 patients were randomized using the Guidant-Nucletron remote control afterloader with a 32P source wire and a centering catheter. Radioactive 32P coated stents have been implanted in 102 patients. In the Isostent Restenosis Intervention Study 1 (IRIS 1), 26 patients received a stent with an activity of 0.75-1.5 μCi, and in the IRIS 2 (European 32P dose response trial), 40 patients were treated with an activity of 6-12 μCi. In two consecutive pilot trials, radioactive stents with non-radioactive ends (cold-end stents) and with ends containing higher levels of activity (hot-end stents) were implanted in 21 and 17 patients, respectively.Results: In the BERT-1.5 trial, the radiation dose, prescribed at 2 mm from the source train (non-centered), was 12 Gy (10 patients), 14 Gy (10 patients) and 16 Gy (11 patients). At 6-month follow-up, 8 out of 28 (29%) patients developed restenosis. The target lesion revascularization rate (TLR) was 7 out of 30 (23%) at 6 months and 8 out of 30 (27%) at 1 year. Two patients presented with late thrombosis in the first year. For compassionate use patients, a restenosis rate (RR) of 53% was observed. In the PREVENT trial, 34 of 37 patients underwent an angiographic 6-month follow-up. The doses prescribed at 0.5 mm depth into the vessel wall were 0 Gy (8), 28 Gy (9), 35 Gy (11) and 42 Gy (8). TLR was 14% in the irradiated patients and 25% in the placebo group. One patient developed late thrombosis. In the IRIS 1 trial, 23 patients showed an RR of 17% (in-stent). In the IRIS 2 trial, in-stent restenosis was not seen in 36 patients at 6-month follow-up. However, a high RR (44%) was observed at the stent edges.Conclusions: The integration of vascular brachytherapy in the catheterization laboratory is feasible and the different treatment techniques that are used are safe. Problems, such as edge restenosis and late thrombotic occlusion, have been identified as limiting factors of this technique. Solutions have been suggested and will be tested in future trials.  相似文献   

10.
Radiochromic film dosimetry is increasingly used in brachytherapy applications for its higher resolution ability as compared to other experimental methods. The present study was aimed to assess the accuracy and suitability of use of the improved radiochromic film model, Gafchromic EBT2, to evaluate the dose distribution in the transverse plane of microselectron HDR 192Ir source.A specially designed and locally fabricated Polymethyl methacrylate (PMMA) phantom was used in this work for the experimental measurement of dose distribution around the source in its transverse plane. The AAPM TG-43U1 recommended radial dose function, g (r), and dose rate constant, Λ, for the source were measured using Gafchromic EBT2 film and thermoluminescent dosimeters (TLD). The EBT2 film measured dosimetric quantities were validated against their values obtained from the TLD measurements and previously published values for the same source available in literature.The dose rate constant and radial dose function for microselectron HDR 192Ir source obtained from Gafchromic EBT2 film measurements are in agreement with their TLD measured results within 3.9% and 2.8% respectively. They also agree within the accepted range of uncertainty with their experimental and Monte Carlo calculated results reported in literature.This work demonstrates the suitability of using Gafchromic EBT2 film dosimetry in characterization of dose distribution in the transverse plane of HDR Ir-192 source. This is a more efficient method than TLD dosimetry at discrete and distant positions. Relative to TLD dosimetry, it is found to be better reproducible, easy to use and a less expensive method of dosimetry.  相似文献   

11.
Intraluminal irradiation of coronary and peripheral arteries has been shown to reduce neointimal hyperplasia following balloon angioplasty, thereby inhibiting restenosis. Several irradiation techniques are being investigated, including temporary intravascular insertion of high activity gamma- or beta-emitting seeds and wires; inflation of dilatation balloon catheter with radioactive liquid or gas; insertion of miniature x-ray tubes via coronary catheters; permanent implantation of radioactive stents; and postangioplasty fractionated external beam irradiation. Unlike conventional brachytherapy, intravascular treatment of restenosis requires accurate knowledge of dose at distances of 0.5-5 mm from the radioactive source. This requirement presents special problems with regard to source calibration and dose specification, because dose gradients at such close distances from a radioactive source are extremely large. This makes it virtually impossible to define the characteristics of an ideal radiation source without some knowledge of the location and radiosensitivity of the target tissues, plus the radiotolerance of normal tissues. Hence, the current debate over whether beta or gamma sources are to be preferred. Imprecise knowledge of dose-volume effects for coronary arteries, plus uncertainties in the biological time sequencing of restenosis fuel a second debate on whether external beam treatments may be efficacious, and whether or not permanent radioactive stents may prove superior to high dose, single fraction brachytherapy. We review here the dosimetric properties of the various irradiation techniques and isotopes that have been proposed, including aspects of radiation safety, dose homogeneity, and practical aspects of source delivery.  相似文献   

12.
PurposeTo investigate the clinical significance of introducing model based dose calculation algorithms (MBDCAs) as an alternative to TG-43 in 192Ir interstitial breast brachytherapy.Materials and methodsA 57 patient cohort was used in a retrospective comparison between TG-43 based dosimetry data exported from a treatment planning system and Monte Carlo (MC) dosimetry performed using MCNP v. 6.1 with plan and anatomy information in DICOM-RT format. Comparison was performed for the target, ipsilateral lung, heart, skin, breast and ribs, using dose distributions, dose-volume histograms (DVH) and plan quality indices clinically used for plan evaluation, as well as radiobiological parameters.ResultsTG-43 overestimation of target DVH parameters is statistically significant but small (less than 2% for the target coverage indices and 4% for homogeneity indices, on average). Significant dose differences (>5%) were observed close to the skin and at relatively large distances from the implant leading to a TG-43 dose overestimation for the organs at risk. These differences correspond to low dose regions (<50% of the prescribed dose), being less than 2% of the prescribed dose. Detected dosimetric differences did not induce clinically significant differences in calculated tumor control probabilities (mean absolute difference <0.2%) and normal tissue complication probabilities.ConclusionWhile TG-43 shows a statistically significant overestimation of most indices used for plan evaluation, differences are small and therefore not clinically significant. Improved MBDCA dosimetry could be important for re-irradiation, technique inter-comparison and/or the assessment of secondary cancer induction risk, where accurate dosimetry in the whole patient anatomy is of the essence.  相似文献   

13.
PurposeThe purpose of the present study was to perform an independent calculation of dosimetric parameters associated with a new 192Ir brachytherapy source model, IRAsource.Materials and methodsThe parameters of air kerma strength (AKS), dose rate constant (DRC), geometry function (GF), radial dose function (RDF), as well as two-dimensional (2D) anisotropy function (AF) of IRAsource 192Ir source model were calculated in this study. The MC n-particle extended (MCNPX) code was also employed for simulating high dose rate (HDR), IRAsource and 192Ir source; and formalism was used for calculating dosimetry parameters based on task group number 43 updated report (TG-43 U1).ResultsThe results of this study were consistent with the ones reported about the IRAsource source by Sarabiasl et al. The AKS per 1 mCi activity and the DRC values were also equal to 3.65 cGycm2 h–1 mCi–1 and 1.094 cGyh–1U–1; respectively. The comparison of the results of the DRC and the RDF reported by Sarabiasl et al. also validated the 192Ir IRAsource simulation in this study. Moreover, the AFs of IRAsource source model were in a good agreement with those of Sarabiasl et al. at different distances, which could be attributed to identical geometries.ConclusionIn line with those reported by Sarabiasl et al., the results of this study confirmed the IRAsource 192Ir source for clinical uses. The calculated dosimetric parameters of the IRAsource source could be utilized in clinical practices as input data sets or for validation of treatment planning system calculations.  相似文献   

14.
In this study version 5 of the MCNP photon transport simulation was used to calculate the dosimetric parameters for new palladium brachytherapy source design following AAPM Task Group No. 43U1 report. The internal source components include four resin beads of 0.6 mm diameters with 103Pd uniformly absorbed inside and one cylindrical copper marker with 1.5 mm length. The resin beads and marker are then encapsulated within 0.8 mm in diameter and 4.5 mm long cylindrical capsule of titanium. The dose rate constant, Λ, line and point-source radial dose function, gL(r) and gP(r), and the anisotropy function, F(r,θ) of the IR01-103Pd seed have been calculated at distances from 0.25 to 5 cm. All the results are in good agreement with previously published thermoluminescence-dosimeter measured values [3] for the source. The dosimetric parameters calculated in this work showed that in dosimetry point of view, the IR01-103Pd seed is suitable for use in brachytherapy of prostate cancer.  相似文献   

15.
In this study, we verified volumetric modulated arc therapy (VMAT) plans in an Elekta Synergy system with an integrated Agility 160-leaf multileaf collimator (MLC) by comparing them with Monte Carlo (MC)-calculated dose distributions using the AAPM TG-119 structure sets. The head configuration of the linear accelerator with the integrated MLC was simulated with the EGSnrc/BEAMnrc code. Firstly, the dosimetric properties of the MLC were evaluated with the MC technique and film measurements. Next, VMAT plans were created with the Pinnacle3 treatment planning system (TPS) for four regions in the AAPM TG-119 structures. They were then verified by comparing them with MC-calculated dose distributions using dose volume histograms (DVHs) and three-dimensional (3D) gamma analysis. The MC simulations for the Agility MLC dosimetric properties were in acceptable agreement with measurements. TPS-VMAT plans using TG-119 structure sets agreed with MC dose distributions within 2% in the comparison of D95 in planning target volumes (PTVs) evaluated from DVHs. In contrast, higher dose regions such as D20, D10, and D5 in PTVs for TPS tended to be smaller than MC values. This tendency was particularly noticeable for mock head and neck with complicated structures. In 3D gamma analysis, the passing rates with 3%/3mm criteria in PTVs were ≥99%, except for mock head and neck (89.5%). All passing rates for organs at risk (OARs) were in acceptable agreement of >96%. It is useful to verify dose distributions of PTVs and OARs in TPS-VMAT plans by using MC dose calculations and 3D gamma analysis.  相似文献   

16.
17.

Introduction

The use of high-dose-rate brachytherapy is currently a widespread practice worldwide. The most common isotope source is 192Ir, but 60Co is also becoming available for HDR. One of main advantages of 60Co compared to 192Ir is the economic and practical benefit because of its longer half-live, which is 5.27 years. Recently, Eckert & Ziegler BEBIG, Germany, introduced a new afterloading brachytherapy machine (MultiSource®); it has the option to use either the 60Co or 192Ir HDR source. The source for the Monte Carlo calculations is the new 60Co source (model Co0.A86), which is referred to as the new BEBIG 60Co HDR source and is a modified version of the 60Co source (model GK60M21), which is also from BEBIG.

Objective and Methods

The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy to investigate the required treatment-planning parameters. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. To validate the source geometry, a few dosimetry parameters had to be calculated according to the AAPM TG-43U1 formalism. The dosimetry studies included the calculation of the air kerma strength S k, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The spectrum to simulate 60Co was composed of two photon energies, 1.17 and 1.33 MeV. Only the gamma part of the spectrum was used; the contribution of the electrons to the dose is negligible because of the full absorption by the stainless-steel wall around the metallic 60Co. The XCOM photon cross-section library was used in subsequent simulations, and the photoelectric effect, pair production, Rayleigh scattering and bound Compton scattering were included in the simulation. Variance reduction techniques were used to speed up the calculation and to considerably reduce the computer time. The cut-off energy was 10 keV for electrons and photons. To obtain the dose rate distributions of the source in an unbounded liquid water phantom, the source was immersed at the center of a cube phantom of 100 cm3. The liquid water density was 0.998 g/cm3, and photon histories of up to 1010 were used to obtain the results with a standard deviation of less than 0.5% (k = 1). The obtained dose rate constant for the BEBIG 60Co source was 1.108±0.001 cGyh-1U-1, which is consistent with the values in the literature. The radial dose functions were compared with the values of the consensus data set in the literature, and they are consistent with the published data for this energy range.  相似文献   

18.
19.
Among various environmental genotoxins, ionizing radiation has received special attention because of its mutagenic, carcinogenic and teratogenic potential. In this context and considering the scarcity of literature data, the objective of the present study was to evaluate the effect of 90Sr beta-radiation on human cells. Blood cells from five healthy donors were irradiated in vitro with doses of 0.2-5.0Gy from a 90Sr source (0.2Gy/min) and processed for chromosome aberration analysis and for comet assay. The cytogenetic results showed that the most frequently found aberration types were acentric fragments, double minutes and dicentrics. The alpha and beta coefficients of the linear-quadratic model, that best fitted the data obtained, showed that 90Sr beta-radiation was less efficient in inducing chromosome aberrations than other types of low linear energy transfer (LET) radiation such as 3H beta-particles, 60Co gamma-rays, 137Cs and 192Ir and X-rays. Apparently, 90Sr beta-radiation in the dose range investigated had no effect on the modal chromosome number of irradiated cells or on cell cycle kinetics. Concerning the comet assay, there was an increase in DNA migration as a function of radiation dose as evaluated by an image analysis system (tail moment) or by visual classification (DNA damage). The dose-response relation adequately fitted the non-linear regression model. In contrast to the cytogenetic data, 90Sr beta-radiation induced more DNA damage than 60Co gamma-radiation when the material was analyzed immediately after exposures. A possible influence of selective death of cells damaged by radiation was suggested.  相似文献   

20.
PurposeA dosimetric audit of Ir-192 high dose rate (HDR) brachytherapy remote after-loading units was carried out in 2019. All six brachytherapy departments on the island of Ireland participated in an end-to-end test and in a review of local HDR dosimetry procedures.Materials and methodsA 3D-printed customised phantom was created to position the following detectors at known distances from the HDR source: a Farmer ionization chamber, GafChromic film and thermoluminescent dosimeters (TLDs). Dedicated HDR applicator needles were used to position an Ir-192 source at 2 cm distance from these detectors. The end-to-end dosimetry audit pathway was performed at each host site and included the stages of imaging, applicator reconstruction, treatment planning and delivery. Deviations between planned and measured dose distributions were quantified using gamma analysis methods. Local procedures were also discussed between auditors and hosts.ResultsThe mean difference between Reference Air Kerma Rate (RAKR) measured during the audit and RAKR specified by the vendor source certificate was 1.3%. The results of end-to-end tests showed a mean difference between calculated and measured dose of 2.5% with TLDs and less than 0.5% with Farmer chamber measurements. GafChromic films showed a mean gamma passing rates of >95% for plastic and metal applicators with 2%/1 mm global tolerance criteria.ConclusionsThe results of this audit indicate dosimetric consistency between centres. The ‘end to end’ dosimetry audit methodology for HDR brachytherapy has been successfully implemented in a multicentre environment, which included different models of Ir-192 sources and different treatment planning systems.The ability to create a 3D-printed water-equivalent phantom customised to accurately position all three detector types simultaneously at controlled distances from the Ir-192 source under evaluation gives good reproducibility for end-to-end methodology.  相似文献   