首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Results are presented from theoretical studies of plasma equilibrium consistent with the convective stability of ideal interchange modes in axisymmetric configurations with an outward-decreasing field that may have a separatrix limiting the plasma volume. A two-dimensional numerical code is developed to solve the Grad-Shafranov equation with a convectively stable pressure distribution at an arbitrary value of β. The problem is solved for an actual geometry of the magnetic field produced by thin current rings. Configurations of a double-dipole confinement system are calculated for the parameters measured in experiments carried out in the Magnetor device, as well as for higher β values. A configuration of a model mirror system with a divertor is also calculated. The code allows one to optimize confinement systems operating at high β values at which equilibrium still can exist.  相似文献   

2.
In the early phase of the Space Shuttle program, NASA flight surgeons implemented a fluid-loading countermeasure in which astronauts were instructed to ingest eight 1-g salt tablets with 960 ml of water approximately 2 hours prior to reentry from space. This fluid loading regimen was intended to enhance orthostatic tolerance by replacing circulating plasma volume reduced during the space mission. Unfortunately, fluid loading failed to replace plasma volume in groundbased experiments and has proven minimally effective as a countermeasure against post-spaceflight orthostatic intolerance. In addition to the reduction of plasma volume, central venous pressure (CVP) is reduced during exposure to actual and groundbased analogs of microgravity. In the present study, we hypothesized that the reduction in CVP due to exposure to microgravity represents a resetting of the CVP operating point to a lower threshold. A lower CVP 'setpoint' might explain the failure of fluid loading to restore plasma volume. In order to test this hypothesis, we conducted an investigation in which we administered an acute volume load (stimulus) and measured responses in CVP, plasma volume and renal functions. If our hypothesis is true, we would expect the elevation in CVP induced by saline infusion to return to its pre-infusion levels in both HDT and upright control conditions despite lower vascular volume during HDT. In contrast to previous experiments, our approach is novel in that it provides information on alterations in CVP and vascular volume during HDT that are necessary for interpretation of the proposed CVP operating point resetting hypothesis.  相似文献   

3.
In rats, prolonged stable hypothermia ( approximately 24 h at body temperature of 19 degrees C) is characterized by a time-dependent increase in hematocrit, plasma osmolality, and red blood cell fragility and a decrease in plasma volume. These changes impede tissue microcirculation and could limit survival. As a countermeasure, we used plasma volume expanders of both long (hetastarch)- and short-lasting (mannitol) characteristics to improve microcirculation and hopefully hypothermia survival. Infusion of 6% hetastarch at hour 3 in hypothermia significantly (P < 0.05) enhanced survival over saline control (33.5 vs. 23.8 h); a significant delay in the increases of hematocrit and cell fragility was also observed compared with those in saline controls. Treating the animal with 6% hetastarch at hour 20 during hypothermia caused a similar but less-effective improvement in survival. In contrast, treating the rats with 6% mannitol at hour 3 or 20 during hypothermia failed to enhance survival over saline control, although transient improvement in plasma volume was observed. Our results indicate that by using a long-lasting volume expander, which tends to better maintain plasma volume and rheological parameters governing microcirculation than does saline or a short-lasting volume expander, hypothermia survival can be significantly improved.  相似文献   

4.
Classically, cold induced plasma volume reduction is explained by an increased diuresis which is generated by an inhibition of antidiuretic hormone release. However, most of the haemoconcentration appears to be reversible during rewarming. This observation weakens the former statement. The aim of this study was to clarify the mechanisms involved in the reversal of the cold induced haemoconcentration. Six young males, resting in a dorsal reclining position, were exposed successively to a thermoneutral environment (30 min), a cold environment (1 degrees C; cold) or thermoneutrality (control) for 120 min, and during a 60-min recovery period in thermoneutral conditions. During cold stress, a reduction of 15% (i.e. 510 ml) of the plasma volume was observed, and osmolality was unchanged. After the 60-min recovery under thermoneutral conditions, plasma volume variation between the Cold and the Control experiments was reduced and reached 3% (i.e. 100 ml). This volume equalled the increased amount of urine production observed during the cold stress experiment. Haemoconcentration cannot be explained by increased urinary water loss (+/- 100 ml) alone. Therefore a transient shift of plasma water from vascular to interstitial spaces, due to an increase of blood pressure, could be involved in the reduction of plasma volume.  相似文献   

5.
Platelet-rich plasma in acidic-citrate-dextrose anticoagulant was kept for 5 days in an oxygen-permeable bag at 22 degrees C in an incubator/rotator. Platelet count remained stable throughout the experiment. On days 0, 3 and 5, aliquots were removed; platelets were isolated by centrifugation at 22 degrees C, 1500 g for 20 min, reconstituted to the original volume with PBS buffer, and the contents of alpha-granules were released by repeated freezing and thawing. Epidermal growth factor (EGF) and beta-thromboglobulin (beta-TG) in the platelet-poor plasma and platelet lysates were determined by radioimmunoassays. Results indicated that in platelet-free plasma, both total EGF and beta-TG increased 3-5-fold after 5 days; this amount represented 10-20% of the factors stored in the platelets. Correspondingly, the EGF and beta-TG contents of the platelet lysates exhibited accompanying decreases. HPLC fractionation showed that the main EGF fraction which progressively decreased in the lysates and increased in plasma had a molecular mass of 140 kDa. The contents of the 67 kDa and 6 kDa fractions did not change substantially. We conclude that under these conditions, the 140 kDa fraction was released preferentially. In view of these and previous experiments, it seems likely that different organs contribute to plasma EGF fractions.  相似文献   

6.
Living cells are characterized by their capacity to maintain a stable steady state. For instance, cells are able to conserve their volume, internal ionic composition and electrical potential difference across the plasma membrane within values compatible with the overall cell functions. The dynamics of these cellular variables is described by complex integrated models of membrane transport. Some clues for the understanding of the processes involved in global cellular homeostasis may be obtained by the study of the local stability properties of some partial cellular processes. As an example of this approach, I perform, in this study, the neighborhood stability analysis of some elementary integrated models of membrane transport. In essence, the models describe the rate of change of the intracellular concentration of a ligand subject to active and passive transport across the plasma membrane of an ideal cell. The ligand can be ionic or nonionic, and it can affect the cell volume or the plasma membrane potential. The fundamental finding of this study is that, within the physiological range, the steady states are asymptotically stable. This basic property is a necessary consequence of the general forms of the expressions employed to describe the active and passive fluxes of the transported ligand.  相似文献   

7.
Results are presented from theoretical and experimental studies of gas-dynamic and radiative processes in the plasma that is planned to be used in future experiments on the stopping of fast heavy-ion beams. These experiments are aimed at measuring the enhanced (as compared to cold substance) plasma stopping power. To reliably interpret the experimental results, it is necessary to create a hydrodynamically stable homogeneous plasma with a uniform temperature and a lifetime exceeding the transit time of the heavy-ion beam (3–5 ns). The method for calculating plasma gas-dynamic characteristics with allowance for radiative heat transfer is described. The specific features of the so-called ion model of plasma, which is used to calculate plasma radiative characteristics, are discussed. The emission spectrum formed as a result of conversion of laser radiation into X-rays and the subsequent passing through a triacetate cellulose (C12H16O8) target is calculated. The simulated spectrum of transmitted radiation satisfactorily agrees with experimental data.  相似文献   

8.
We performed the following experiments to evaluate the accuracy of our newly developed radioimmunoassay for somatostatin: (1) Recovery of synthetic somatostatin added to human, porcine, and canine plasma with or without extraction with 67% acetone or 76% ethanol, using 3 different region-specific antibodies and, where applicable, 125I-labelled Tyr-1- or Tyr-11-substituted somatostatin or 125I-N-Tyr-somatostatin as tracers. The recovery of somatostatin corrected for losses inherent in the extraction procedure was close to 100%, and independent of species, antibody and tracer. Somatostatin 1-28 was extracted slightly less efficiently. Unextracted plasma interfered massively in the assay. (2) Pharmacokinetic experiments with infusion of somatostatin into 14 pigs and determination of metabolic clearance rate (MCR) and T-1/2. MCR was 27-38 ml/kg per min, independent of infusion rate (6.1 or 13 pmol/kg per min), extraction procedure or tracer. T-1/2 was 1.9 min. The infused somatostatin was not measurable in unextracted plasma. (3) Characterization of endogenous and exogenous, labelled and unlabelled somatostatin 1-14 in human plasma, using Sephadex G-50 columns at pH 7.5 and 9.0. Human plasma showed excess immunoreactivity eluting at the void volume whereas synthetic somatostatin was recovered quantitatively at the position of marker somatostatin when added to the plasma. The immunoreactivity of the tracers was decreased (125I-Tyr-11-somatostatin) or abolished (125I-N-Tyr- or 125I-Tyr-1-somatostatin) after incubation with plasma or void volume fractions of plasma subjected to gel filtration. Extracted plasma did not contain void volume immunoreactivity, but like whole plasma, small amounts of components which coeluted with intact somatostatin.  相似文献   

9.
This movie shows how an atmospheric pressure plasma torch can be ignited by microwave power with no additional igniters. After ignition of the plasma, a stable and continuous operation of the plasma is possible and the plasma torch can be used for many different applications. On one hand, the hot (3,600 K gas temperature) plasma can be used for chemical processes and on the other hand the cold afterglow (temperatures down to almost RT) can be applied for surface processes. For example chemical syntheses are interesting volume processes. Here the microwave plasma torch can be used for the decomposition of waste gases which are harmful and contribute to the global warming but are needed as etching gases in growing industry sectors like the semiconductor branch. Another application is the dissociation of CO2. Surplus electrical energy from renewable energy sources can be used to dissociate CO2 to CO and O2. The CO can be further processed to gaseous or liquid higher hydrocarbons thereby providing chemical storage of the energy, synthetic fuels or platform chemicals for the chemical industry. Applications of the afterglow of the plasma torch are the treatment of surfaces to increase the adhesion of lacquer, glue or paint, and the sterilization or decontamination of different kind of surfaces. The movie will explain how to ignite the plasma solely by microwave power without any additional igniters, e.g., electric sparks. The microwave plasma torch is based on a combination of two resonators — a coaxial one which provides the ignition of the plasma and a cylindrical one which guarantees a continuous and stable operation of the plasma after ignition. The plasma can be operated in a long microwave transparent tube for volume processes or shaped by orifices for surface treatment purposes.  相似文献   

10.
Plasma volume was decreased by prolonged bicycle exercise, by passive heating in warm water, by sauna dehydration, and by diuretically induced dehydration in eleven well trained subjects. Blood samples from an arm vein were taken before and after this pre-treatment, as well as after a subsequent standard exercise test (SET) on a bicycle ergometer (50%, 70% and 105% of max VO2; the SET with no pre-treatment was used as a control condition. The changes in plasma concentration of Na+, K+ and Cl- were not proportional to the calculated plasma volume changes. The Na+ and Cl- concentrations always increased in the plasma, while plasma potassium concentration was increased after prolonged exercise, but decreased after the other types of dehydrations. The standard exercise test produced a pronounced fall in total calculated plasma potassium and in K+ concentration measured 3-5 min after exercise in all types of experiments. In the standard exercise test the calculated water loss from the plasma volume was relatively large. It amounted to about 2/3 of the total water loss in the standard exercise test and was independent of the pre-treatments.  相似文献   

11.
A new luminescence procedure based on the creatine kinase reaction was developed for measuring creatine in plasma. The method is highly applicable to small animal work where the amount of blood volume is critical. Only 20 microliter of sample is necessary for creatine analysis. Deproteinizing the plasma sample with ethanol at room temperature is convenient. This extraction method is adaptable to a clinical setting. The ethanol used in the extraction is compatible with the luminescence method but precipitated enzymes in the NADH spectrophotometric method because of the greater sample volume needed for analysis. The creatine concentration is stable in plasma for at least 1 hr in a final anticoagulant concentration of 10 mM EDTA. The correlation between the new luminescence method with the established NADH spectrophotometric method was excellent (r = 0.99). The accuracy of the within-run precision is high, with a mean coefficient of variation, 2-3%. Plasma creatine levels could be an important indicator denoting early cellular damage and of potential prognostic value. Preliminary studies in human muscle ischemia and early shock in rabbits revealed a significant increase in plasma creatine levels. Further investigations are necessary to evaluate its clinical importance.  相似文献   

12.
Atrial natriuretic factor inhibits vasopressin secretion in conscious sheep   总被引:1,自引:0,他引:1  
To test the hypothesis that atrial natriuretic factor (ANF) has a centrally mediated action on body fluid homeostasis, the effects of intracerebroventricularly (ICV) infused ANF on plasma vasopressin (AVP) concentration and urinary water and electrolyte excretion were investigated in euhydrated and water-deprived conscious sheep. ICV ANF decreased plasma AVP concentration and increased urinary free water excretion in euhydrated sheep, with excretion of Na and K unaltered. However, ICV ANF did not affect urinary volume, free water clearance, or excretion of Na and K in dehydrated animals, although plasma AVP concentration was significantly decreased. The relationship between urine volume and plasma AVP concentration was fitted by a power curve: urine volume = 0.79 X [AVP]-0.71; urine volume changes very little as a function of AVP concentration at the higher ranges. Intravenous infusion of the same amount of ANF was without effect on plasma AVP concentration or urinary excretion in both euhydrated and dehydrated animals. Mean arterial pressure was unchanged throughout all experiments. These results are consistent with the hypothesis that central ANF inhibits AVP secretion.  相似文献   

13.
We examined the plasma volume changes associated with a protocol of either exercise or controlled rest under identical positional and ambient conditions. Nine healthy adult males rode (E) and on another occasion sat quietly (C) on a cycle ergometer for 30 min. Ten minutes of cycle exercise immediately followed the resting C protocol. Ambient temperature was 30 degrees C (rh = 35%) and exercise load was equal to 50% of peak VO2. Venous blood samples were obtained with subjects both in the supine and seated positions prior to all experiments. Additional blood was drawn during minutes 1, 5, 10, and 30 in both experimental conditions. A final sample was taken during C after the 10 min exercise. Moving from the supine to a seated position resulted in an average loss of 162 ml of plasma across all experiments. During the E condition a further reduction in plasma volume (76 ml) occurred by one minute of exercise. Plasma volume stabilized by 5 min of exercise under the E protocol. During the C condition, subsequent fluid loss (98 ml) was not apparent until 10 min after the first seated sample and totalled 176 ml at the end of 30 min of rest. Ten minutes of cycling at the end of the C experiment resulted in a further plasma volume reduction of 137 ml. Plasma protein and albumin contents decreased by 5 min of exercise in E and by 30 min of rest in C. [Na+] and [Cl-] did not change in either condition but a rapid increase in [K+] during exercise indicated an addition of potassium to the vascular volume.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
The in vitro experiments show that the anticoagulant affect of a new AT III-Heparin-complex preparation in plasma is similar to heparin. The in vivo experiments indicate that the thrombin inhibition is even improved by using the complex preparation, because the aPTT values after complex treatment remained stable for more than one hour in the desired range. Bleeding complications are less likely after complex treatment, because much smaller maximum aPTT values are reached. The prolonged half life of the complex preparation possibly allows a reduced and more accurate dosage.  相似文献   

15.
"In a recent study of male and female ultra-marathoners in a 161-km ultra-marathon, the prevalence of exercise-associated hyponatremia (EAH) was higher than reported for marathoners. Regarding triathletes, the prevalence of EAH has been investigated in Ironman triathletes, but not in Triple Iron ultra-triathletes. The aim of this study was to investigate the prevalence of EAH in male ultra-triathletes competing in a Triple Iron ultra-triathlon over 11.4 km swimming, 540 km cycling, and 126.6 km running. Changes in body mass, fat mass, skeletal muscle mass, total body water, haematocrit, plasma volume, plasma sodium concentration ([Na ? ]) and urine specific gravity were determined in 31 male athletes with (means ± standard deviation) 42.1 ± 8.1 years of age, 77.0 ± 7.0 kg body mass, 1.78 ± 0.06 m body height and a BMI of 24.3 ± 1.7 kg/m2 in the 'Triple Iron Triathlon Germany'. Of the 31 finishers, eight athletes (26%) developed asymptomatic EAH. Body mass, fat mass, skeletal muscle mass, and haematocrit decreased, plasma volume increased ( P < 0.05), plasma [Na ?], total body water and urine specific gravity remained stable. The decrease in body mass was related to both the decrease in fat mass and skeletal muscle mass ( P < 0.05), but was not related to overall race time, the change in plasma [Na ? ], post-race plasma [Na ? ], or urine specific gravity. The prevalence of EAH was higher in these Triple Iron ultra-triathletes compared to existing reports on Ironman triathletes. Body fluid homeostasis remained stable in these ultra-triathletes although body mass decreased."  相似文献   

16.
Atrial natriuretic factor (ANF) causes an increase in hematocrit that cannot be accounted for by urinary losses. The mechanism behind this phenomenon was studied in intact and splenectomized rats. Rat ANF 99-126 was infused i.v. for 30 min into conscious rats at rates of 0 (saline control), 0.05, or 0.1 microgram/min. Plasma volume was then determined by dilution of the dye, Evan's Blue. In one group of rats, red cell volume was determined using 51Cr-labelled erythrocytes. ANF infusion was continued uninterrupted throughout the experiments. In the intact rats, ANF (0.10 microgram/min) caused hematocrit to increase from 38.9 +/- 0.5 to 41.2 +/- 0.4% (p < 0.005). Splenectomy so attenuated this response to ANF that it failed to reach significance. Similarly, ANF (0.10 microgram/min) caused plasma volume to fall from 5.1 +/- 0.1 to 4.5 +/- 0.1 mL/100 g body wt. (p < 0.005) in the intact rats, but did not affect plasma volume in the splenectomized rats. As a result, blood volume was significantly reduced by ANF in the intact rats, but remained unchanged in the splenectomized rats. Red cell volume did not change in response to infusion of ANF, nor did ANF affect the rate of clearance of Evan's Blue out of the plasma. It is concluded that the spleen is an important site of movement of protein-poor fluid out of the vasculature, and that this exchange is influenced by ANF.  相似文献   

17.
Incoherent scattering of a probing wave by Langmuir fluctuations trapped and enhanced near a local minimum of the electron density (plasma density well) in plasma with a parabolic density profile is considered. Steady-state amplitudes of fluctuations are calculated for arbitrary velocity distribution functions of plasma particles with allowance for electron collisions. It is shown that quasi-periodic oscillations with two characteristic scales can be present in the spectrum of the plasma line. The smaller scale is due to the wellknown effect of discretization of the spectrum of Langmuir fluctuations in a plasma density well. The larger scale is associated with the generation of scattered waves in two spatial regions and subsequent interference of these waves at the exit from the density well. Oscillations with this scale are more stable under unsteady plasma conditions and can be more often observed in experiments. The results of this work can be used to experimentally determine the plasma parameters, such as the electron collision frequency and the size and lifetime of the plasma density well.  相似文献   

18.
To investigate a possible function of plasma albumin in partitioning organic anions into bile and urine, phenolsulfonphthalein (PSP) was administered intravenously and its in vivo fate was studied in normal and analbuminemic mutant rats (NAR). No significant change in the rate of PSP disappearance was observed in bilaterally nephrectomized normal rats. However, biliary excretion of the injected dye increased remarkably in nephrectomized normal rats. Intravenously injected PSP disappeared very rapidly from the circulation of NAR. Thus, the plasma clearance and distribution volume of PSP were significantly larger in NAR than in normal rats. Bilateral nephrectomy also failed to decrease the plasma clearance and distribution volume of the dye in NAR. In striking contrast to the experiments in normal rats, bilateral nephrectomy did not increase the biliary secretion of PSP in NAR. When PSP bound to equimolar albumin was injected into bilaterally nephrectomized NAR, the biliary excretion of PSP increased significantly with concomitant decrease in both plasma clearance and distribution volume of the dye. These results indicate that, in cases of renal transport dysfunction, albumin plays a critical role in hepatic compensatory excretion of PSP, a nephrophilic organic anion, whose molecular weight (MW 354) is close to the threshold value for partitioning a ligand to the eliminatory routes in liver and kidney of a rodent.  相似文献   

19.
The method of intravenous administration of UV-irradiated donor plasma to patients with jaundice of different genesis has been tested in the experiments on rats and used clinically in 20 patients. Biochemical and morphological studies have shown that such treatment causes stable improvement in the liver functional state.  相似文献   

20.
During the first exposure of exercising subjects to hot environments (30-50 degrees C), cardiac output, heart rate, and body temperature increase over that seen in cool environments, while stroke volume decreases. If daily heat exposures occur, during the second heat exposure, heart rates and rectal temperatures are decreased from day 1 while cardiac output is maintained. This decrease in physiological strain occurs with little or no increase in evaporative heat loss. The alleviating agent appears to be an expansion of plasma volume. Several brief studies have indicated decreases in cardiac filling pressure during exercise in heat, and though inferential, it appears that the progressive increase in plasma volume during the first five to six days of heat exposure assists in maintaining cardiac filling pressure. Later, with increased evaporative heat loss due to increased sweat secretion, the mechanism of supplying increased volume to maintain cardiac filling is changed; fluid is transferred from extravascular to intravascular compartment, thus protecting venous return and cardiac filling pressure. These statements are based on limited data, and there is need of experiments designed to confirm or deny certain conclusions as to the role of cardiac filling pressure in acclimatization to heat.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号