首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We describe a method for the detection and quantification of nucleoside diphosphate kinase (NDPK). NDPK catalyzes the transfer of the gamma-phosphate of cytidine 5'-triphosphate on uridine 5'-diphosphate (UDP) to produce uridine 5'-triphosphate (UTP). The method uses a nonradioactive coupled enzyme assay in which UTP produced by NDPK is utilized by UDP-glucose pyrophosphorylase. This latter enzyme synthesizes UDP-glucose and inorganic phosphate in the presence of glucose 1-phosphate. UDP-glucose is detected at 260 nm after separation of the reaction mixture by high-performance liquid chromatography (HPLC) on a strong anion-exchange column. The assay is reliable, specific, and linear with respect to time and enzyme amount. Using 15 min incubation time, the method allows detection of NDPK activity below 10 pmol/min. It can be used to analyze kinetic behavior and to quantify NDPK from a wide variety of animal, microbial, and plant sources. It also provides an alternative to radiometric assays and an improvement on pyruvate kinase-linked spectrophotometric assays, which can be hampered by pigments present in crude extracts. Furthermore, we show that the HPLC method developed here can be directly used to assay enzymes for which UDP-glucose is a product.  相似文献   

2.
A new fluorogenic acceptor for sialyltransferase, 2-[(2-pyridyl)amino]ethyl O-beta-D-galactopyranosyl-(1----4)-beta-D-glucopyranoside, was prepared from lactose as a starting material. Sialyltransferase activity was assayed by incubation of the enzyme with the acceptor and CMP-N-acetylneuraminic acid, separation of the fluorogenic sialylated product from the enzymatic reaction mixture by HPLC, and measurement of the product. Compared to assays so far reported that use radioactive substrates, this assay is simple and rapid. This method was used to assay sialyltransferase activity in human serum.  相似文献   

3.
A new, selective and sensitive high-performance liquid chromatography (HPLC) method with fluorimetric detection was developed for the determination of tianeptine (TIA) in human plasma using solid phase extraction (SPE) procedures. The method is based on the derivatization of TIA with 4-chloro-7-nitrobenzofurazan (NBD-Cl) in borate buffer of pH 8.5 to yield a yellow, fluorescent product. The HPLC separation was achieved on a Phenomenex C(18) column (250 mm x 4.6 mm) using a mobile phase of acetonitrile-10mM orthophosphoric acid (pH 2.5) (77:23, v/v) solvent system at 1 mL/min flow rate. Gabapentin (GA) was used as the internal standard. The fluorometric detector was operated at 458 nm (excitation) and 520 nm (emission). The assay was linear over the concentration range of 5-300 ng/mL. The detection limit (LOD) was found to be 2 ng/mL. The mean recovery was determined to be 88.6%. The proposed method was applied for pharmacokinetic study of 12.5mg TIA in a healthy volunteer.  相似文献   

4.
The most popular method to determine the activity of myosin light chain kinase is to measure the radioactivity incorporated from [gamma-32P]ATP into phosphoryl-accepting substrates. In this paper, we report a new method for determination of myosin light chain kinase activity without using radioisotopes. Synthetic peptides and nonradiolabeled ATP were used as substrate, and the peptide substrate was phosphorylated by myosin light chain kinase purified from chicken gizzard. After terminating the reaction, the reaction mixture was directly injected into a reversed-phase HPLC column without pretreatment, separated with the isocratic solvent system of acetonitrile-H2O-trifluoroacetic acid, and monitored at 220 nm uv absorbance. The reaction rate was determined from the peak areas of phosphorylated and unphosphorylated peptides. One chromatographic separation was achieved within 9 min, and the analysis could be repeated successively more than 100 times without washing the column. Using this method, we measured the differential inhibition of myosin light chain kinase by various inhibitors. With the aid of an automatic injector, the HPLC method with synthetic peptide enables us to handle many samples quickly and is useful for screening new myosin light chain kinase inhibitors.  相似文献   

5.
A system has been developed for the determination of quinolinate phosphoribosyltransferase (QPRT) activity in liver and kidney homogenates using HPLC. A product, nicotinic acid mononucleotide (NaMN), is separated by reversed-phase chromatography (a Tosoh ODS 80TS was used as an analytical column) using a mixture of 10 mM KH2PO4–K2HPO4 buffer (pH 7.0) containing 1.48 g/l tetra-n-butylammonium bromide–acetonitrile (9:1, v/v) as a mobile phase. The flow-rate was 1.0 ml/min, the detection wavelength was 265 nm. The column temperature was maintained at 40°C. Under these conditions, NaMN was eluted at about 8.1 min. Sample preparation was very straightforward. The reaction mixture of QPRT assay was stopped by immersing the tube into a boiling water bath, the resulting supernatant was filtered, and the filtrate was directly injected into a HPLC system. The total HPLC analysis time was approximately 20 min.  相似文献   

6.
We describe a rapid and efficient high-performance liquid chromatography procedure for the separation of phospholipids. The separation is accomplished on a microparticulate silica gel column using isocratic elution and UV detection at 203 nm. The solvent mixture is acetonitrile—methanol—85% phosphoric acid(130:5:1.5, v/v). Complete separation is achieved within 30 min of phosphatidylinositol, phosphatidylserine, phosphatidylethanolamine, phosphatidyldimethylethanolamine, lysophosphatidylethanolamine, phosphatidylcholine, lysophosphatidylcholine and sphingomyelin. The method is suitable for the analysis of phospholipids in tissue extracts.  相似文献   

7.
For toxicological purposes, a HPLC assay was developed for the simultaneous determination of risperidone and 9-hydroxyrisperidone in human plasma. After a single-step liquid-liquid extraction, both compounds were separated on a C(18) column and measured at 280 nm. A good inter-assay accuracy (<116%) was achieved with inter-assay precision less than 12%. Quantification limits were 10 ng/ml. This rapid method (run time <5 min) is currently used for poison management.  相似文献   

8.
A high-performance liquid chromatographic method has been developed for the resoiusion of DNA bases and deoxyribonucleosides in mixture. The isocratic separation based on ion exelusion was achieved in column of 250-mm length and 2 mm i.d. packed with the spherical, totally porous anex OSTION LGAT 0800 of particle size 10–12 μm. The mobile phase consists of 5 mm ammonium formate pH 4.5 and complete resolution of an eight-component system is possible at a flow rate of 2 ml/h in 100 min. Rapid separation of the components, with exception of Cyt-dCyd, is reached at flow rate of 20 ml/h in 10 min.  相似文献   

9.
Determination of hydroxyproline by high pressure liquid chromatography.   总被引:4,自引:0,他引:4  
A rapid, precise, and simple HPLC method provides an assay of hydroxyproline from tissue extracts or solutions of collagen. Samples are hydrolyzed with 6 N HCl, derivatized with phenyl isothiocyanate, and chromatographed on a small, C18 reverse-phase HPLC column. Hydroxyproline (Hyp) is separated from other amino acids and detected by absorption at 254 nm. The method detects 0.40 to 36 micrograms of Hyp with a linear response. Separation requires a total of 6 min, including column cleanup and reequilibration. All components are commercially available, making this a convenient method for routine measurement of collagen concentration.  相似文献   

10.
In many peptide hormones and neuropeptides, the carboxy-terminal alpha-amide structure is essential in eliciting biological activity. In the present study, a rapid and sensitive assay method for the determination of peptidylglycine alpha-amidating monooxygenase (PAM) activity has been reported. This method is based on the monitoring of the absorption at 460 nm of 4-dimethylaminoazobenzene-4'-sulfonyl-Gly-L-Phe-NH2 (Dabsyl-Gly-Phe-NH2), enzymatically formed from the substrate 4-dimethylaminoazobenzene-4'-sulfonyl-Gly-L-Phe-Gly, after separation by high-performance liquid chromatography (HPLC) using a C-18 reversed-phase column by isocratic elution. This method is sensitive enough to measure Dabsyl-Gly-Phe-NH2 at concentrations as low as 1 pmol and yield highly reproducible results and requires less than 5 min per sample for separation and quantitation. The concentrations of copper and ascorbic acid required for maximal enzyme activity were 1 microM and 2 mM, respectively. The pH optimum for PAM activity was 5.0 to 5.5. The Km and Vmax values were respectively 3.5 microM and 100 pmol/micrograms/h with the use of enzyme extract obtained from bovine pituitary. By using this method, PAM activity could be readily detected in a single rat saliva. The sensitivity of this assay method will also aid in the effort to examine the regulation of in vivo PAM activity.  相似文献   

11.
High-pressure liquid chromatography (reverse-phase mode) was used to assay adenosine kinase in cell and tissue extracts. The method is optimized for a rapid and selective analysis using 6-methylthiopurine riboside as substrate, isocratic elution and detection at 300 nm. A complete separation of substrate and product is achieved in about 3 min with no interference by other UV-absorbing compounds; the limit of detection is 20 pmoles.  相似文献   

12.
Chemically modified phosphorothioate oligodeoxynucleotides (ODNs) have become critical tools for research in the fields of gene expression and experimental therapeutics. Bioanalytical assays were developed that utilized fast anion-exchange high-performance liquid chromatography (HPLC) and capillary gel electrophoresis (CGE) for the determination of 20-mer ODNs in biological fluids (plasma and urine) and tissues. A 20 mer ODN in the antisense orientation directed against DNA methyltransferase (denoted as MT-AS) was studied as the model ODN. The anion-exchange HPLC method employed a short column packed with non-porous polymer support and a ternary gradient elution with 2 M lithium bromide containing 30% formamide. Analysis of the MT-AS is accomplished within 5 min with a detection limit of approximately 3 ng on-column at 267 nm. For plasma and urine, samples were diluted with Nonidet P-40 in 0.9% NaCl and directly injected onto the column, resulting in 100% recovery. For tissue homogenates, a protein kinase K digestion and phenol–chloroform extraction were used, with an average recovery of about 50%. Since the HPLC assay cannot provide one-base separation, biological samples were also processed by an anion-exchange solid-phase extraction and a CGE method to characterize MT-AS and its catabolites of 15–20-mer, species most relevant to biological activity. One base separation, under an electric field of 400 V/cm at room temperature, was achieved for a mixture of 15–20-mer with about 50 pg injected. Assay validation studies revealed that the combined HPLC–CGE methods are accurate, reproducible and specific for the determination of MT-AS and its catabolites in biological fluids and tissue homogenates, and can be used for the pharmacokinetic characterization of MT-AS.  相似文献   

13.
A simple, rapid and sensitive high-performance liquid chromatography (HPLC) method was developed for the enantioselective analysis of the new antidepressant drug mirtazapine in human plasma. The procedure involved liquid-liquid extraction using toluene, followed by liquid chromatography coupled to UV detection at 292 nm. The chromatographic separation of the (+)-(S)- and (-)-(R)-enantiomers of mirtazapine was achieved on a Chiralpak AD column (250 mm x 4.6 mm, 10 microm particle size) protected with a CN guard column, using hexane-ethanol (98:2, v/v) plus 0.1% diethylamine as the isocratic mobile phase, at a flow rate of 1.2 ml/min. The total analysis time was less than 12 min per sample. The recoveries of (+)-(S)- and (-)-(R)-mirtazapine were in the 88-111% range with a linear response over the 6.25-625 ng/ml concentration range for both enantiomers. The quantification limit (LOQ) was 5 ng/ml. Within-day and between-day assay precision and accuracy were studied at three concentration levels (10, 50 and 250 ng/ml). For both mirtazapine enantiomers, the coefficients of variation (CV) and deviation from the theoretical value were lower than 15% at all concentration levels. The method proved to be suitable for pharmacokinetic studies.  相似文献   

14.
A rapid, sensitive and reproducible reversed-phase HPLC assay was developed for the determination of amprolium (APL) in chicken plasma. Protein in plasma sample was precipitated with 0.33 M perchloric acid and supernatant solution was injected into the HPLC system. Following the chromatographic separation of APL and the beclotiamine (I.S.) on a C18 column, the derivatives of APL and I.S. were formed by post-column reaction and detected by fluorescence detection (excitation at 400 nm, emission at 460 nm). The method showed excellent precision, accuracy and speed with a detection limit of 2 ng/ml. The intra- and inter-assay variance of this method were less than 11.2%. This method has been successfully applied to plasma determinations after oral administration of APL to chicken.  相似文献   

15.
A systematic optimization of the HPLC separation of a complex mixture containing natural and synthetic anabolic steroids by micellar liquid chromatography using a Hypersil (150 mm x 3.0 mm i.d., 5 microm) C18 column and UV detection at 245 nm (exception is made for oxymetolone and danazol which were monitorized at 280 nm) has been carried out. The isocratic micellar mobile phases (from binary to quaternary) consisted of sodium dodecyl sulphate and organic modifiers such as acetonitrile, tetrahydrofuran, propanol, butanol or pentanol. The effect of the organic modifiers, surfactant concentration, temperature, ionic strength and flow-rate on the separation has been studied. A micellar mobile phase 5% propanol and 40 mM surfactant allowed the separation of 12 steroids out of 14 tested in about 20 min. A bivariant optimization method for the micellar mobile phase propanol-surfactant corroborated the above results.  相似文献   

16.
Two simple, rapid and sensitive methods, namely, fourth‐derivative synchronous spectrofluorimetry (method I) and HPLC with fluorescence detection (method II) were developed for the simultaneous analysis of a binary mixture of itopride HCl (ITP) and domperidone (DOM) without prior separation. The first method was based on measuring the fourth derivative of the synchronous fluorescence spectra of the two drugs at Δλ = 40 nm in methanol. The different experimental parameters affecting the synchronous fluorescence of the studied drugs were carefully optimized. Chromatographic separation was performed in < 6.0 min using a RP C18 column (250 mm × 4.6 mm i.d., 5 µm particle size) with fluorescence detection at 344 nm after excitation at 285 nm. A mobile phase composed of a mixture of 0.02 M phosphate buffer with acetonitrile in a ratio of 55 : 45, pH 4.5, was used at a flow rate of 1 mL/min. Linearity ranges were found to be 0.1–2 µg/mL for ITP in both methods, whereas those for DOM were found to be 0.08–2 and 0.05–1.5 µg/mL in methods I and II, respectively. The proposed methods were successfully applied for the determination of the studied drugs in synthetic mixtures and laboratory‐prepared tablets. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
A simple, rapid and precise HPLC method has been developed for the assay of verapamil in human plasma. The clean up of the plasma samples was tested using several adsorbents for solid-phase extraction and best recovery was obtained using mixed-mode cartridges (HLB - hydrophilic-lipophilic balance) ranging between 94.70 and 103.71%. HPLC separation was performed with isocratic elution on Lichrospher 60 RP-select B column (250 mm × 4 mm I.D., 5 μm particle size). The mobile phase was 40% acetonitrile and 0.025 mol/L KH2PO4 with pH 2.5 at flow rate of 1 mL/min. Diltiazem was used as internal standard and the detection wavelength was 200 nm. The calibration curves were linear in the range of 10–500 ng/mL. The developed method is convenient for routine analysis of verapamil in human plasma.  相似文献   

18.
A rapid and simple high-performance liquid chromatographic (HPLC) method has been developed and validated for determination of scopoletin in rat plasma using psoralen as internal standard. Chromatographic separation was achieved on a C(18) column using methanol and distilled water (49:51, v/v) containing 0.05% (v/v) phosphoric acid as mobile phase. The UV detector was set at 345 nm. The calibration curve was linear over the range of 0.165-9.90 microg/ml with a correlation coefficient of 0.9994. The recovery for plasma samples of 0.165, 1.32 and 6.60 microg/ml was 93.2%, 95.9% and 95.5%, respectively. The RSD of intra- and inter-day assay variations was less than 6.7%. This HPLC assay is a precise and reliable method for the analysis of scopoletin in pharmacokinetic studies.  相似文献   

19.
A rapid and sensitive method using HPLC has been developed for the quantification of nicorandil (SG-75) in human plasma samples for routine bioequivalence studies. The sample preparation needs two liquid–liquid extractions, first with CH3Cl and HClO4 as denaturation reagent and second with addition of ethyl acetate and Na2CO3(aq). Detection wavelength was 256 nm. The obtained correlation coefficient for weighted linear curve in the range from 5.0 to 300 ng/ml was higher than 0.9950. The limit of quantitation (LOQ) was established at 5.0 ng/ml. The HPLC separation was accomplished on Nucleosil Phenyl (5 μm) stainless steel column within 7 min. The mixture of 0.01 M ammonium acetate buffer (pH 6.2) and acetonitrile 10:3 (v/v) was used as the mobile phase. The same separation method was examined on HPLC–MS system. Using this system, the LOQ was established at 1.0 ng/ml and the linearity was obtained in the range from 1.0 to 150 ng/ml.  相似文献   

20.
New polar reversed-phase stationary phases in HPLC provide specific selectivities which can help to solve traditional chromatographic problems related to the development of chromatographic methods with widely different retention times for the sample components. One such case is the analysis of pharmaceutical formulations against the common cold. Acetaminophen, phenylephrine and chlorpheniramine, compounds with different polarities, are frequently associated in these drugs. An isocratic and rapid HPLC method for the simultaneous determination of the three compounds, acetaminophen, phenylephrine and chlorpheniramine, in capsules as pharmaceutical formulations, including the separation of impurities (4-aminophenol and 4-chloracetanilide) and excipients, has been developed and validated. The final chromatographic conditions employed a Supelco Discovery HS PEG column poly(ethyleneglycol) 15x0.46 cm, 5 microm. The mobile phase was 20 mM phosphate buffer, pH 7.0-acetonitrile (90:10, v/v) at a flow-rate of 1 ml/min. UV detection was performed at 215 nm for all the compounds except acetaminophen, which was measured at 310 nm. Validation parameters permit us to consider this method suitable.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号