首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The recent revolution in cryo-EM has produced an explosion of structures at near-atomic or better resolution. This has allowed cryo-EM structures to provide visualization of bound small-molecule ligands in the macromolecules, and these new structures have provided unprecedented insights into the molecular mechanisms of complex biochemical processes. They have also had a profound impact on drug discovery, defining the binding modes and mechanisms of action of well-known drugs as well as driving the design and development of new compounds. This review will summarize and highlight some of these structures. Most excitingly, the latest cryo-EM technology has produced structures at 1.2 Å resolution, further solidifying cryo-EM as a powerful tool for drug discovery. Therefore, cryo-EM will play an ever-increasing role in drug discovery in the coming years.  相似文献   

2.
Baker ML  Zhang J  Ludtke SJ  Chiu W 《Nature protocols》2010,5(10):1697-1708
With single-particle electron cryomicroscopy (cryo-EM), it is possible to visualize large, macromolecular assemblies in near-native states. Although subnanometer resolutions have been routinely achieved for many specimens, state of the art cryo-EM has pushed to near-atomic (3.3-4.6 ?) resolutions. At these resolutions, it is now possible to construct reliable atomic models directly from the cryo-EM density map. In this study, we describe our recently developed protocols for performing the three-dimensional reconstruction and modeling of Mm-cpn, a group II chaperonin, determined to 4.3 ? resolution. This protocol, utilizing the software tools EMAN, Gorgon and Coot, can be adapted for use with nearly all specimens imaged with cryo-EM that target beyond 5 ? resolution. Additionally, the feature recognition and computational modeling tools can be applied to any near-atomic resolution density maps, including those from X-ray crystallography.  相似文献   

3.
Cryogenic electron microscopy (cryo-EM) has become in the past 10 years one of the major tools for the structure determination of proteins. Nowadays, the structure prediction field is experiencing the same revolution and, using AlphaFold2, it is possible to have high-confidence atomic models for virtually any polypeptide chain, smaller than 4000 amino acids, in a simple click. Even in a scenario where all polypeptide chain folding were to be known, cryo-EM retains specific characteristics that make it a unique tool for the structure determination of macromolecular complexes. Using cryo-EM, it is possible to obtain near-atomic structures of large and flexible mega-complexes, describe conformational panoramas, and potentially develop a structural proteomic approach from fully ex vivo specimens.  相似文献   

4.
The field of membrane protein structural biology has been revolutionized over the last few years with a number of high profile structures being solved using cryo-EM including Piezo, Ryanodine receptor, TRPV1 and the Glutamate receptor. Further developments in the EM field hold the promise of even greater progress in terms of greater resolution, which for membrane proteins is still typically within the 4–7 Å range. One advantage of a cryo-EM approach is the ability to study membrane proteins in more “native” like environments for example proteoliposomes, amphipols and nanodiscs. Recently, styrene maleic acid co-polymers (SMA) have been used to extract membrane proteins surrounded by native lipids (SMALPs) maintaining a more natural environment. We report here the structure of the Escherichia coli multidrug efflux transporter AcrB in a SMALP scaffold to sub-nm resolution, with the resulting map being consistent with high resolution crystal structures and other EM derived maps. However, both the C-terminal helix (TM12) and TM7 are poorly defined in the map. These helices are at the exterior of the helical bundle and form the greater interaction with the native lipids and SMA polymer and may represent a more dynamic region of the protein. This work shows the promise of using an SMA approach for single particle cryo-EM studies to provide sub-nm structures.  相似文献   

5.
Nine different near-atomic resolution structures of icosahedral viruses, determined by electron cryo-microscopy and published between early 2008 and late 2010, fulfil predictions made 15 years ago that single-particle cryo-EM techniques could visualize molecular detail at 3-4? resolution. This review summarizes technical developments, both in instrumentation and in computation, that have led to the new structures, which advance our understanding of virus assembly and cell entry.  相似文献   

6.
Cryogenic electron microscopy (cryo-EM) is now one of the most powerful and widely used methods to determine high-resolution structures of macromolecules. A major bottleneck of cryo-EM is to prepare high-quality vitrified specimen, which still faces many practical challenges. During the conventional vitrification process, macromolecules tend to adsorb at the air–water interface (AWI), which is known unfriendly to biological samples. In this review, we outline the nature of AWI and the problems caused by it, such as unpredictable or uneven particle distribution, protein denaturation, dissociation of complex and preferential orientation. We review and discuss the approaches and underlying mechanisms to deal with AWI: 1) Additives, exemplified by detergents, forming a protective layer at AWI and thus preserving the native folds of target macromolecules. 2) Fast vitrification devices based on the idea to freeze in-solution macromolecules before their touching of AWI. 3) Thin layer of continuous supporting films to adsorb macromolecules, and when functionalized with affinity ligands, to specifically anchor the target particles away from the AWI. Among these supporting films, graphene, together with its derivatives, with negligible background noise and mechanical robustness, has emerged as a new generation of support. These strategies have been proven successful in various cases and enable us a better handling of the problems caused by the AWI in cryo-EM specimen preparation.  相似文献   

7.
Electron cryo-microscopy (cryo-EM) images are commonly collected using either charge-coupled devices (CCD) or photographic film. Both film and the current generation of 16 megapixel (4k × 4k) CCD cameras have yielded high-resolution structures. Yet, despite the many advantages of CCD cameras, more than two times as many structures of biological macromolecules have been published in recent years using photographic film. The continued preference to film, especially for subnanometer-resolution structures, may be partially influenced by the finer sampling and larger effective specimen imaging area offered by film. Large format digital cameras may finally allow them to overtake film as the preferred detector for cryo-EM. We have evaluated a 111-megapixel (10k × 10k) CCD camera with a 9 μm pixel size. The spectral signal-to-noise ratios of low dose images of carbon film indicate that this detector is capable of providing signal up to at least 2/5 Nyquist frequency potentially retrievable for 3D reconstructions of biological specimens, resulting in more than double the effective specimen imaging area of existing 4k × 4k CCD cameras. We verified our estimates using frozen-hydrated ε15 bacteriophage as a biological test specimen with previously determined structure, yielding a ~7 ? resolution single particle reconstruction from only 80 CCD frames. Finally, we explored the limits of current CCD technology by comparing the performance of this detector to various CCD cameras used for recording data yielding subnanometer resolution cryo-EM structures submitted to the electron microscopy data bank (http://www.emdatabank.org/).  相似文献   

8.

Background

Since the introduction of what became today's standard for cryo-embedding of biological macromolecules at native conditions more than 30 years ago, techniques and equipment have been drastically improved and the structure of biomolecules can now be studied at near atomic resolution by cryo-electron microscopy (cryo-EM) while capturing multiple dynamic states. Here we review the recent progress in cryo-EM for structural studies of dynamic biological macromolecules.

Scope of review

We provide an overview of the cryo-EM method and introduce contemporary studies to investigate biomolecular structure and dynamics, including examples from the recent literature.

Major conclusions

Cryo-EM is a powerful tool for the investigation of biological macromolecular structures including analysis of their dynamics by using advanced image-processing algorithms. The method has become even more widely applicable with present-day single particle analysis and electron tomography.

General significance

The cryo-EM method can be used to determine the three-dimensional structure of biomacromolecules in near native condition at close to atomic resolution, and has the potential to reveal conformations of dynamic molecular complexes. This article is part of a Special Issue entitled "Biophysical Exploration of Dynamical Ordering of Biomolecular Systems" edited by Dr. Koichi Kato.  相似文献   

9.
A significant number of macromolecular structures solved by electron cryo-microscopy and X-ray crystallography obtain resolutions of 3.5-6?, at which direct atomistic interpretation is difficult. To address this, we developed pathwalking, a semi-automated protocol to enumerate reasonable Cα models from near-atomic resolution density maps without a structural template or sequence-structure correspondence. Pathwalking uses an approach derived from the Traveling Salesman Problem to rapidly generate an ensemble of initial models for individual proteins, which can later be optimized to produce full atomic models. Pathwalking can also be used to validate and identify potential structural ambiguities in models generated from near-atomic resolution density maps. In this work, examples from the EMDB and PDB are used to assess the broad applicability and accuracy of our method. With the growing number of near-atomic resolution density maps from cryo-EM and X-ray crystallography, pathwalking can become an important tool in modeling protein structures.  相似文献   

10.
11.
In bifidobacteria, phosphoketolase (PKT) plays a key role in the central hexose fermentation pathway called “bifid shunt.” The three-dimensional structure of PKT from Bifidobacterium longum with co-enzyme thiamine diphosphate (ThDpp) was determined at 2.1 Å resolution by cryo-EM single-particle analysis using 196,147 particles to build up the structural model of a PKT octamer related by D4 symmetry. Although the cryo-EM structure of PKT was almost identical to the X-ray crystal structure previously determined at 2.2 Å resolution, several interesting structural features were observed in the cryo-EM structure. Because this structure was solved at relatively high resolution, it was observed that several amino acid residues adopt multiple conformations. Among them, Q546–D547–H548–N549 (the QN-loop) demonstrate the largest structural change, which seems to be related to the enzymatic function of PKT. The QN-loop is at the entrance to the substrate binding pocket. The minor conformer of the QN-loop is similar to the conformation of the QN-loop in the crystal structure. The major conformer is located further from ThDpp than the minor conformer. Interestingly, the major conformer in the cryo-EM structure of PKT resembles the corresponding loop structure of substrate-bound Escherichia coli transketolase. That is, the minor and major conformers may correspond to “closed” and “open” states for substrate access, respectively. Moreover, because of the high-resolution analysis, many water molecules were observed in the cryo-EM structure of PKT. Structural features of the water molecules in the cryo-EM structure are discussed and compared with water molecules observed in the crystal structure.  相似文献   

12.
Radiation damage is the primary factor that limits resolution in electron cryo-microscopy (cryo-EM) of frozen-hydrated biological samples. Negative effects of radiation damage are attenuated by cooling specimens to cryogenic temperatures using liquid nitrogen or liquid helium. We have examined the relationship between specimen temperature and radiation damage across a broad spectrum of resolution by analyzing images of frozen-hydrated catalase crystal at four specimen temperatures: 4, 25, 42, and 100 K. For each temperature, “exposure series” were collected consisting of consecutive images of the same area of sample, each with 10 e?2 exposure per image. Radiation damage effects were evaluated by examining the correlation between cumulative exposure and normalized amplitudes or IQ values of Bragg peaks across a broad range of resolution (4.0–173.5 Å). Results indicate that for sub-nanometer resolution, liquid nitrogen specimen temperature (100 K) provides the most consistent high-quality data while yielding statistically equivalent protection from radiation damage compared to the three lower temperatures. At lower resolution, suitable for tomography, intermediate temperatures (25 or 42 K) may provide a modest improvement in cryo-protection without introducing deleterious effects evident at 4 K.  相似文献   

13.
Structural analysis by electron microscopy of biological macromolecules or macromolecular assemblies embedded in rapidly frozen, vitreous ice has made great advances during the last few years. Electron cryo-microscopy, or cryo-EM, can now be used to analyse the structures of molecules arranged in the form of two-dimensional crystals, helical arrays or as single particles with or without symmetry. Although it has been possible, using crystalline or helical specimens, to reach a resolution adequate to build atomic models (4 A), there is every hope this will soon also be possible with single particles. Small and large single particles present different obstacles to progress.  相似文献   

14.
Liquid-electron microscopy (EM), the room temperature correlate to cryo-EM, is an exciting new technique delivering real-time data of dynamic reactions in solution. Here, we explain how liquid-EM gained popularity in recent years by examining key experiments conducted on viral assemblies and host–pathogen interactions. We describe developing workflows for specimen preparation, data collection, and computing processes that led to the first high-resolution virus structures in a liquid environment. Equally important, we review why liquid-electron tomography may become the next big thing in biomedical research due to its ability to monitor live viruses entering cells within seconds. Taken together, we pose the idea that liquid-EM can serve as a dynamic complement to current cryo-EM methods, inspiring the “real-time revolution” in nanoscale imaging.  相似文献   

15.
Electron cryo-microscopy (cryo-EM) has played an increasingly important role in elucidating the structure and function of macromolecular assemblies in near native solution conditions. Typically, however, only non-atomic resolution reconstructions have been obtained for these large complexes, necessitating computational tools for integrating and extracting structural details. With recent advances in cryo-EM, maps at near-atomic resolutions have been achieved for several macromolecular assemblies from which models have been manually constructed. In this work, we describe a new interactive modeling toolkit called Gorgon targeted at intermediate to near-atomic resolution density maps (10-3.5 ?), particularly from cryo-EM. Gorgon's de novo modeling procedure couples sequence-based secondary structure prediction with feature detection and geometric modeling techniques to generate initial protein backbone models. Beyond model building, Gorgon is an extensible interactive visualization platform with a variety of computational tools for annotating a wide variety of 3D volumes. Examples from cryo-EM maps of Rotavirus and Rice Dwarf Virus are used to demonstrate its applicability to modeling protein structure.  相似文献   

16.
After a general introduction to three-dimensional electron microscopy and particularly to electron tomography (ET), the perspectives of applying ET to native (frozen–hydrated) cellular structures are discussed. In ET, a set of 2-D images of an object is recorded at different viewing directions and is then used for calculating a 3-D image. ET at a resolution of 2–5 nm would allow the 3-D organization of structural cellular components to be studied and would provide important information about spatial relationships and interactions. The question of whether it is a realistic long-term goal to visualize or—by sophisticated pattern recognition methods— identify macromolecules in cells frozenin totoor in frozen sections of cells is addressed. Because of the radiation sensitivity of biological specimens, a prerequisite of application of ET is the automation of the imaging process. Technical aspects of automated ET as realized in Martinsried and experiences are preresented, and limitations of the technique are identified, both theoretically and experimentally. Possible improvements of instrumentation to overcome at least part of the limitations are discussed in some detail. Those means include increasing the accelerating voltage into the intermediate voltage range (300 to 500 kV), energy filtering, the use of a field emission gun, and a liquid-helium-cooled specimen stage. Two additional sections deal with ET of isolated macromolecules and of macromolecular structuresin situ,and one section is devoted to possible methods for the detection of structures in volume data.  相似文献   

17.
Recent progress in cryo-EM research has ignited a revolution in biological macromolecule structure determination. Resolution is an essential parameter for quality assessment of a cryo-EM density map, and it is known that resolution varies in different regions of a map. Currently available methods for local resolution estimation require manual adjustment of parameters and in some cases necessitate acquisition or de novo generation of so-called “half maps”. Here, we developed CryoRes, a deep-learning algorithm to estimate local resolution directly from a single final cryo-EM density map, specifically by learning resolution-aware patterns of density map voxels through supervised training on a large dataset comprising 1,174 experimental cryo-EM density maps. CryoRes significantly outperforms all of the state-of-the-art competing resolution estimation methods, achieving an average RMSE of 2.26 Å for local resolution estimation relative to the currently most reliable FSC-based method blocres, yet requiring only the single final map as input. Further, CryoRes is able to generate a molecular mask for each map, with accuracy 12.12% higher than the masks generated by ResMap. CryoRes is ultra-fast, fully automatic, parameter-free, applicable to cryo-EM subtomogram data, and freely available at https://cryores.zhanglab.net.  相似文献   

18.
The Volta phase plate is a recently developed electron cryo-microscopy (cryo-EM) device that enables contrast enhancement of biological samples. Here we have evaluated the potential of combining phase-plate imaging and single particle analysis to determine the structure of a small protein–DNA complex. To test the method, we made use of a 200 kDa Nucleosome Core Particle (NCP) reconstituted with 601 DNA for which a high-resolution X-ray crystal structure is known. We find that the phase plate provides a significant contrast enhancement that permits individual NCPs and DNA to be clearly identified in amorphous ice. The refined structure from 26,060 particles has an overall resolution of 3.9 Å and the density map exhibits structural features consistent with the estimated resolution, including clear density for amino acid side chains and DNA features such as the phosphate backbone. Our results demonstrate that phase-plate cryo-EM promises to become an important method to determine novel near-atomic resolution structures of small and challenging samples, such as nucleosomes in complex with nucleosome-binding factors.  相似文献   

19.
The recent technological advances in electron microscopes, detectors, as well as image processing and reconstruction software have brought single particle cryo-electron microscopy (cryo-EM) into prominence for determining structures of bio-molecules at near atomic resolution. This has been particularly true for virus capsids, ribosomes, and other large assemblies, which have been the ideal specimens for structural studies by cryo-EM approaches. An analysis of time series metadata of virus structures on the methods of structure determination, resolution of the structures, and size of the virus particles revealed a rapid increase in the virus structures determined by cryo-EM at near atomic resolution since 2010. In addition, the data highlight the median resolution (~3.0?Å) and size (~310.0?Å in diameter) of the virus particles determined by X-ray crystallography while no such limits exist for cryo-EM structures, which have a median diameter of 508?Å. Notably, cryo-EM virus structures in the last four years have a median resolution of 3.9?Å. Taken together with minimal sample requirements, not needing diffraction quality crystals, and being able to achieve similar resolutions of the crystal structures makes cryo-EM the method of choice for current and future virus capsid structure determinations.  相似文献   

20.
Although cryo-electron microscopy (cryo-EM) of biological macromolecules has made important advances in the past few years, the level of current technical performance is still well below what the physics of electron scattering would allow. It should be possible, for example, to use cryo-EM to solve protein structures at atomic resolution for particle sizes well below 80 kDa, but currently this has been achieved only for particles at least 10 times larger than that. In this review, we first examine some of the reasons for this large gap in performance. We then give an overview of work that is currently in progress to 1), improve the signal/noise ratio for area detectors; 2), improve the signal transfer between the scattered electrons and the corresponding images; and 3), reduce the extent to which beam-induced movement causes a steep fall-off of signal at high resolution. In each case, there is substantial reason to think that cryo-EM can indeed be made to approach the estimated physical limits.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号