共查询到20条相似文献,搜索用时 0 毫秒
1.
用环介导等温扩增技术快速检测粪便样本中的沙门菌 总被引:2,自引:0,他引:2
目的:建立快速检测粪便样本中的沙门菌的环介导等温扩增技术(LAMP),并着重在灵敏度和特异性方面对此方法进行评价。方法:利用LAMP针对沙门菌特定基因invA(靶基因)设计的6条特异引物,通过引物特异性识别特定基因invA上的8个独立区域来快速检测沙门菌;LAMP反应过程中会产生白色沉淀焦磷酸镁,故可以通过监测浊度来判定反应结果。结果:实时浊度仪监测反应结果表明,LAMP反应在60~65℃等温条件下50 min内完成;如果在反应前添加羟基萘酚兰,蓝色阳性结果很明显区别于紫色阴性结果;LAMP的最低检出限为6.97 pg/μL,PCR为69.7pg/μL,LAMP方法的检测灵敏度是PCR的10倍,且具有良好的特异性。结论:LAMP方法用于快速检测沙门菌,具有检测过程简单、实验装置简便、反应结果肉眼可辨、灵敏度高、特异性强的特点,对非沙门菌菌株的结果呈阴性,表明引物设计有很好的特异性。对粪便样本进行检测,发现具有同样的敏感性和特异性。这表明LAMP法是潜在的和有价值的在粪便样本中直接检测沙门菌的方法,具有快速、简便、低成本的特点。LAMP法适用于快速临床诊断。 相似文献
2.
Hua-Bing Zhao Guang-Ya Yin Guo-Ping Zhao Ai-Hua Huang Jun-Hong Wang Shuang-Feng Yang Hong-Sheng Gao Wei-Jun Kang 《Indian journal of microbiology》2014,54(1):80-86
Enteroviruses are found in most environments and cause several diseases in humans. Loop-mediated isothermal amplification (LAMP) was adapted and evaluated for the rapid detection of enteroviruses. Based on the highly conserved 5′ untranslated region (5′-UTR) of the human enteroviruses (HEVs), particularly human enterovirus A (HEV-A) and HEV-B, a set of universal primers was designed. The LAMP amplification was carried out under isothermal conditions at 61 °C, depending on the template concentration results were obtained within 45–90 min. The detection limits were found to be 101 copies of cloned enterovirus 71 fragments, more sensitive than conventional PCR. Nine water samples collected from drinking water sources during three seasons and 19 stool specimens collected from HFMD patients were analyzed. By using the LAMP assay, the majority of samples was tested positive, 9/9 (100 %) and 18/19 (94.7 %), respectively. LAMP is a practical method for the rapid detection of enteroviruses in environmental and clinical samples. 相似文献
3.
DoKyung Lee Eun Jin Kim Paul E. Kilgore Soon Ae Kim Hideyuki Takahashi Makoto Ohnishi Dang Duc Anh Bai Qing Dong Jung Soo Kim Jun Tomono Shigehiko Miyamoto Tsugunori Notomi Dong Wook Kim Mitsuko Seki 《PloS one》2015,10(4)
BackgroundNeisseria meningitidis (Nm) is a leading causative agent of bacterial meningitis in humans. Traditionally, meningococcal meningitis has been diagnosed by bacterial culture. However, isolation of bacteria from patients’ cerebrospinal fluid (CSF) is time consuming and sometimes yields negative results. Recently, polymerase chain reaction (PCR)-based diagnostic methods of detecting Nm have been considered the gold standard because of their superior sensitivity and specificity compared with culture. In this study, we developed a loop-mediated isothermal amplification (LAMP) method and evaluated its ability to detect Nm in cerebrospinal fluid (CSF).Conclusions/SignificanceCompared to PCR, LAMP detected Nm with higher analytical and clinical sensitivity. This sensitive and specific LAMP method offers significant advantages for screening patients on a population basis and for diagnosis in clinical settings. 相似文献
4.
5.
副溶血弧菌LAMP检测方法的建立 总被引:26,自引:0,他引:26
副溶血弧菌(Vibrio parahaemolyticus)是一种能引起食源性疾病的重要病原菌。首次将一种新颖的核酸扩增技术-环介导等温扩增技术(Loop-Mediated Isothermal Amplification, LAMP)应用于副溶血弧菌的快速检测。针对副溶血弧菌不耐热溶血毒素基因(tlh)设计四条特异性引物(两条内引物和两条外引物)进行LAMP扩增,对扩增反应进行优化,最佳反应时间为60 min,反应温度为60 ℃。对12种细菌共28株菌进行LAMP扩增,仅14株副溶血弧菌得到阳性扩增结果,证明引物具有很高的特异性。副溶血弧菌基因组DNA和纯培养物的检测灵敏度分别约为90 fg和24 cfu/mL。对模拟食品样品进行直接检测,检测限为89 cfu/g。结果表明,该方法检测副溶血弧菌特异性强、灵敏度高,并且操作简便、检测成本低,1 h即可完成,有望发展成为快速检测副溶血弧菌的有效手段。 相似文献
6.
Wei Yan Zhongyuan Shen Xudong Tang Li Xu Qianlong Li Yajie Yue Shengyan Xiao Xuliang Fu 《Current microbiology》2014,69(4):532-540
We successfully established a detection method which exhibited a markedly higher sensitivity than previously developed detection methods for Nosema bombycis by combining glass beads, FTA card, and LAMP. Spores of N. bombycis were first broken by acid-washed glass beads; the DNA was subsequently extracted and purified with the FTA card, and LAMP was performed using primers (LSU296) designed based on the sequence of the LSU rRNA of N. bombycis. The minimum detection concentration was 10 spores/mL. When this method was used to detect pebrine disease in silkworm egg, the detection rate for 500 silkworm eggs, in which only one egg was infected with N. bombycis, was 100 % under our optimized conditions. If the number of eggs in the sample increased to 800 or 1,000, the sample was divided into two equal portions, and the eggs were smashed with glass beads after the addition of 1 mL of TE buffer. The liquid in two tubes was later mixed and applied to the FTA card, and the detection rates were 100 %. Furthermore, the LAMP method established in our study could detect N. bombycis infection in silkworm 24 h earlier than microscopy. 相似文献
7.
Zablon Kithinji Njiru Andrew Stanislaw John Mikosza Tanya Armstrong John Charles Enyaru Joseph Mathu Ndung'u Andrew Richard Christopher Thompson 《PLoS neglected tropical diseases》2008,2(2)
Loop-mediated isothermal amplification (LAMP) of DNA is a novel technique that rapidly amplifies target DNA under isothermal conditions. In the present study, a LAMP test was designed from the serum resistance-associated (SRA) gene of Trypanosoma brucei rhodesiense, the cause of the acute form of African sleeping sickness, and used to detect parasite DNA from processed and heat-treated infected blood samples. The SRA gene is specific to T. b. rhodesiense and has been shown to confer resistance to lysis by normal human serum. The assay was performed at 62°C for 1 h, using six primers that recognised eight targets. The template was varying concentrations of trypanosome DNA and supernatant from heat-treated infected blood samples. The resulting amplicons were detected using SYTO-9 fluorescence dye in a real-time thermocycler, visual observation after the addition of SYBR Green I, and gel electrophoresis. DNA amplification was detected within 35 min. The SRA LAMP test had an unequivocal detection limit of one pg of purified DNA (equivalent to 10 trypanosomes/ml) and 0.1 pg (1 trypanosome/ml) using heat-treated buffy coat, while the detection limit for conventional SRA PCR was ∼1,000 trypanosomes/ml. The expected LAMP amplicon was confirmed through restriction enzyme RsaI digestion, identical melt curves, and sequence analysis. The reproducibility of the SRA LAMP assay using water bath and heat-processed template, and the ease in results readout show great potential for the diagnosis of T. b. rhodesiense in endemic regions. 相似文献
8.
目的:建立基于环介导等温扩增(LAMP)技术的单孢子虫可视化检测方法。方法:根据尼氏单孢子虫的小亚基核糖体RNA保守序列,设计一套特异性LAMP引物,对反应条件如温度和试剂浓度进行优化,建立检测牡蛎单孢子虫的LAMP方法。结果:所建立的方法的敏感性可达1 fg,是常规PCR方法的100倍;全部反应可在1 h内完成;可通过肉眼观察颜色,直接判定结果;对其他牡蛎常见病原体的检测结果均为阴性。结论:建立的LAMP方法简便、快速、灵敏、特异,可用于牡蛎单孢子虫感染的快速检测。 相似文献
9.
目的:建立一种快速、简便、特异性高的鸭瘟病毒(DPV)环介导等温扩增(LAMP)检测方法。方法:根据Gen Bank中DPVUI6基因的保守序列设计一套特异性引物,并对反应条件进行优化,建立DPV的LAMP可视化检测方法。结果:建立的LAMP方法对其他鸭常见病原体无扩增反应;可通过肉眼观察颜色直接判定结果;敏感性可达0.1fg,是常规PCR方法的100倍;扩增反应只须在常规水浴锅中进行,可在1 h内完成。结论:建立的DPV LAMP方法简便、快速、灵敏、特异,可用于DPV感染的快速检测。 相似文献
10.
Aongart Mahittikorn Hirotake Mori Supaluk Popruk Amonrattana Roobthaisong Chantira Sutthikornchai Khuanchai Koompapong Sukhontha Siri Yaowalark Sukthana Duangporn Nacapunchai 《PloS one》2015,10(3)
Naegleria fowleri is the causative agent of the fatal disease primary amebic meningoencephalitis. Detection of N. fowleri using conventional culture and biochemical-based assays is time-consuming and laborious, while molecular techniques, such as PCR, require laboratory skills and expensive equipment. We developed and evaluated a novel loop-mediated isothermal amplification (LAMP) assay targeting the virulence-related gene for N. fowleri. Time to results is about 90 min and amplification products were easily detected visually using hydroxy naphthol blue. The LAMP was highly specific after testing against related microorganisms and able to detect one trophozoite, as determined with spiked water and cerebrospinal fluid samples. The assay was then evaluated with a set of 80 water samples collected during the flooding crisis in Thailand in 2011, and 30 natural water samples from border areas of northern, eastern, western, and southern Thailand. N. fowleri was detected in 13 and 10 samples using LAMP and PCR, respectively, with a Kappa coefficient of 0.855. To the best of our knowledge, this is the first report of a LAMP assay for N. fowleri. Due to its simplicity, speed, and high sensitivity, the LAMP method described here might be useful for quickly detecting and diagnosing N. fowleri in water and clinical samples, particularly in resource-poor settings. 相似文献
11.
Pedro Fernández-Soto Prosper Obolo Mvoulouga Jean Paul Akue Julio López Abán Belén Vicente Santiago Miguel Cordero Sánchez Antonio Muro 《PloS one》2014,9(4)
The filarial parasite Loa loa, the causative agent of loiasis, is endemic in Central and Western Africa infecting 3–13 million people. L. loa has been associated with fatal encephalopathic reactions in high Loa-infected individuals receiving ivermectin during mass drug administration programs for the control of onchocerciasis and lymphatic filariasis. In endemic areas, the only diagnostic method routinely used is the microscopic examination of mid-day blood samples by thick blood film. Improved methods for detection of L. loa are needed in endemic regions with limited resources, where delayed diagnosis results in high mortality. We have investigated the use of a loop-mediated isothermal amplification (LAMP) assay to facilitate rapid, inexpensive, molecular diagnosis of loiasis. Primers for LAMP were designed from a species-specific repetitive DNA sequence from L. loa retrieved from GenBank. Genomic DNA of a L. loa adult worm was used to optimize the LAMP conditions using a thermocycler or a conventional heating block. Amplification of DNA in the LAMP mixture was visually inspected for turbidity as well as addition of fluorescent dye. LAMP specificity was evaluated using DNA from other parasites; sensitivity was evaluated using DNA from L. loa 10-fold serially diluted. Simulated human blood samples spiked with DNA from L. loa were also tested for sensitivity. Upon addition of fluorescent dye, all positive reactions turned green while the negative controls remained orange under ambient light. After electrophoresis on agarose gels, a ladder of multiple bands of different sizes could be observed in positive samples. The detection limit of the assay was found to be as little as 0.5 ag of L. loa genomic DNA when using a heating block. We have designed, for the first time, a highly sensitive LAMP assay for the detection of L. loa which is potentially adaptable for field diagnosis and disease surveillance in loiasis-endemic areas. 相似文献
12.
Kuiyu Jiang Ying Zhu Wenxin Liu Yufei Feng Lili He Weikun Guan Wenxia Hu Dongfang Shi 《Current microbiology》2012,65(5):633-638
The objective of this study was to establish a loop-mediated isothermal amplification (LAMP) method for the detection of F5 fimbriae gene in Enterotoxigenic Escherichia coli. A set of four primers were designed based on the conservative sequence of coding F5 fimbriae. Temperature and time condition, specificity test, and sensitivity test were performed with the DNA of Escherichia coli (F5+). The results showed that the optimal reaction condition for LAMP was achieved at 61 °C for 45 min in a water bath. Ladder-like products were produced with those F5-positive samples by LAMP, while no product was generated with other negative samples. The assay of LAMP had a detection limit equivalent to 72 cfu/tube, which was more sensitive than PCR (7.2 × 102 cfu/tube). The agreement rate between LAMP and PCR was 100 % in detecting simulation samples. Thus, the LAMP assay may be a new method for rapid detection of F5 fimbriae gene of ETEC. 相似文献
13.
In this study, the loop-mediated isothermal amplification (LAMP) method was used to develop a rapid and simple detection system for porcine circovirus type 2 (PCV2). According to the PCV2 sequences published in GenBank, multiple LAMP primers were designed targeting conserved sequences of PCV2. Using the DNA extracted from PCV2 isolates HUN-09 and SD-09 as the template, LAMP reactions in a PCV2 LAMP system was performed, the amplification products were detected by adding SYBR Green I and could be observed di... 相似文献
14.
Xanthomonas fragariae is a bacterium that causes angular leaf spot of strawberry. Asymptomatic infection is common and contributes to the difficulties in disease management. The aim of this study was to develop a loop-mediated isothermal amplification (LAMP) assay as an efficient method for detection of asymptomatic infections of X. fragariae. In addition, a new method of sample preparation was developed that allows sampling of a larger amount of plant tissue, hence increasing the detection rate in real-life samples. The sample preparation procedure includes an overnight incubation of strawberry tissues in phosphate-buffered saline (PBS), followed by a quick sample concentration and a boiling step to extract DNA for amplification. The detection limit of the LAMP assay was approximately 2×103 CFU/mL for pure bacteria culture and 300 CFU/mL for bacteria spiked strawberry leaf and petiole samples. LAMP provided a 2–3 fold lower detection limit than the standard qPCR assay but was faster, and more user-friendly. The LAMP assay should serve as a rapid, sensitive and cost-effective tool for detecting asymptomatic infections of X. fragariae in strawberry nursery stock and contribute to improved disease management. 相似文献
15.
《亚洲两栖爬行动物研究(英文版)》2015,(1)
Loop-mediated isothermal amplification(LAMP) is a novel nucleic acid diagnostic method that can amplify rapidly a target template under isothermal conditions. In this study, a LAMP assay for rapid detection of Chinese giant salamander ranavirus(CGSRV) was developed from culture isolates and clinical samples. The LAMP assay was developed by designing one set of four specific primers, targeting the major capsid protein(MCP) gene of CGSRV. Reaction time and temperature were optimal for 40 min at 62°C. The developed LAMP assay is specific and highly sensitive for CGSRV detection, the detection limit could reach about 5 copies of cloned viral genomic fragments. The sensitivity of the LAMP assay was about 1000 and 10-fold higher than that of both conventional and nested PCR, respectively. The LAMP amplification produces a typical ladder-like pattern of products on an agarose gel that can be visually inspected after addition of ethidium bromide. The LAMP assay was evaluated further with clinical samples, and the results indicated the suitability and simplicity of the test as a rapid diagnostic tool for the detection of CGSRV. 相似文献
16.
空肠弯曲菌LAMP快速检测方法的建立 总被引:2,自引:0,他引:2
本研究使用恒温环介导技术, 以空肠弯曲菌的促旋酶基因A(gyrA)设计引物, 建立空肠弯曲菌的LAMP快速检测方法。不同来源的4株空肠弯曲菌LAMP检测均显示阳性, 其他14种细菌LAMP检测显示阴性。实验结果表明, 设计的引物具有良好的特异性。本研究进行了LAMP检测方法与细菌平板计数法和PCR法的灵敏度比较, 结果LAMP检测与PCR法有相近的灵敏度, 比细菌平板计数法灵敏度高3个数量级。我们还研究发现提取核酸前加入DNase可以有效地减少死菌DNA对LAMP结果的影响。使用LAMP方法对鸡法氏囊的检测表明, 结合核酸提取步骤中的DNase处理步骤, 可以准确的检测出鸡法氏囊中的空肠弯曲菌。 相似文献
17.
18.
Xing-Wei Ni Donald P. McManus Zhong-Zi Lou Ji-Fei Yang Hong-Bin Yan Li Li Hong-Min Li Quan-Yuan Liu Chun-Hua Li Wan-Gui Shi Yan-Lei Fan Xu Liu Jin-Zhong Cai Meng-Tong Lei Bao-Quan Fu Yu-Rong Yang Wan-Zhong Jia 《PloS one》2014,9(7)
Background
Cystic echinococcosis is highly prevalent in northwest China. A cost-effective, easy to operate diagnostic tool with high sensitivity and specificity would greatly facilitate the monitoring of Echinococcus infections in canine definitive hosts.Methods
The primers used in the LAMP assay were based on the mitochondrial nad5 gene of E. granulosus sensu stricto (E. granulosus s.s., or E.g.s.s.) and were designed using Primer Explorer V4 software. The developed LAMP assay was compared with a conventional PCR method, copro-ELISA and microscopy, using the faeces of dogs experimentally infected with E.g.s.s., and field-collected faeces of domestic dogs including 190 from Qinghai province highly endemic for E.g.s.s. and 30 controls from an area in Gansu, where a domestic dog de-worming program was in operation.Results
The positivity rates obtained for the field-collected faecal samples were 12.6%, 1.6% and 2.1% by the LAMP, PCR and copro-ELISA assays, respectively. All samples obtained from the control dogs were negative. Compared with the conventional PCR, the LAMP assay provided 88.8% specificity and 100% sensitivity. The higher sensitivity of the LAMP method was also shown by the fact that it could detect the presence of laboratory challenge dog infections of E. granulsous s.s. four days earlier than the PCR method. Three copro-samples shown positive by the commercial copro-ELISA were all negative by LAMP, PCR and microscopy, which suggests these samples may have originated from another infection rather than E. granulsous s.s., possibly E. shiquicus or E. Canadensis, which is also present in China.Conclusions
We have developed a potentially useful surveillance tool for determining the prevalence of canine E. granulosus s.s. infections in the field. The LAMP assay may lead to a more cost-effective and practicable way of tracking Echinococcus infections in canids, especially when combined with the copro-ELISA. 相似文献19.
Botrytis cinerea is a devastating plant pathogen that causes grey mould disease. In this study, we developed a visual detection method of B. cinerea based on the Bcos5 sequence using loop-mediated isothermal amplification (LAMP) with hydroxynaphthol blue dye (HNB). The LAMP reaction was optimal at 63°C for 45 min. When HNB was added prior to amplification, samples with B. cinerea DNA developed a characteristic sky blue color after the reaction but those without DNA or with DNA of other plant pathogenic fungi did not. Results of HNB staining method were reconfirmed when LAMP products were subjected to gel electrophoresis. The detection limit of this LAMP assay for B. cinerea was 10−3 ng µL−1 of genomic DNA per reaction, which was 10-fold more sensitive than conventional PCR (10−2 ng µL−1). Detection of the LAMP assay for inoculum of B. cinerea was possible in the inoculated tomato and strawberry petals. In the 191 diseased samples, 180 (94.2%) were confirmed as positive by LAMP, 172 (90.1%) positive by the tissue separation, while 147 (77.0%) positive by PCR. Because the LAMP assay performed well in aspects of sensitivity, specificity, repeatability, reliability, and visibility, it is suitable for rapid detection of B. cinerea in infected plant materials prior to storage and during transportation, such as cut flowers, fruits and vegetables. 相似文献
20.
Application of a Loop-Mediated Isothermal Amplification Assay for Rapid Detection of Cow Components Adulterated in Buffalo Milk/Meat 总被引:1,自引:0,他引:1
Rajib Deb Gyanendra Singh Sengar Umesh Singh Sushil Kumar R. R. Alyethodi Rani Alex T. V. Raja A. K. Das B. Prakash 《Molecular biotechnology》2016,58(12):850-860