首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BACKGROUND: Development of spectrally distinct green fluorescent protein (GFP) variants has allowed for simultaneous flow cytometric detection of two different colored mutants expressed in a single cell. However, the dual-laser methods employed in such experiments are not widely applicable since they require a specific, expensive laser, and single-laser analysis at 488 nm exhibits considerable spectral overlap. The purpose of this work was to evaluate detection of enhanced cyan fluorescent protein (ECFP) in combination with the enhanced green (EGFP) and enhanced yellow (EYFP) fluorescent proteins by flow cytometry. METHODS: Cells transfected with expression constructs for EGFP, EYFP, or ECFP were analyzed by flow cytometry using excitation wavelengths at 458, 488, or 514 nm. Fluorescence signals were separated with a custom optical filter configuration: 525 nm shortpass and 500 nm longpass dichroics; 480/30 (ECFP), 510/20 (EGFP) and 550/30 (EYFP) bandpasses; 458 nm laser blocking filters. RESULTS: All three fluorescent proteins when expressed individually or in combination in living cells were excited by the 458 nm laser line and their corresponding signals could be electronically compensated in real time. CONCLUSIONS: This method demonstrates the detection of three fluorescent proteins expressed simultaneously in living cells using single laser excitation and is applicable for use on flow cytometers equipped with a tunable argon ion laser.  相似文献   

2.
An improved multisensor cell sorting instrument for quantitative analysis and sorting of cells has been developed. Cells stained with fluorescent dyes enter a flow chamber where cell volume, fluorescence, and light scatter sensors simultaneously measure multiple cellular properties. Cells then emerge in a liquid jet that is broken into uniform liquid droplets. Sensor signals are electronically processed in one of several ways for optimum cell discrimination and are displayed as pulse-amplitude distributions using a multichannel pulse-height analyzer. Processed signals activate cell sorting according to preselected parametric criteria by electrically charging droplets containing cells and electrostatically deflecting them into collection vessels. Illustrative examples of multiparameter cell analysis and sorting experiments using a model mouse tumor cell system, human and animal leukocytes, and cultured mammalian cells are presented.  相似文献   

3.
Flow cytometric procedures are described to detect a "humanized" version of a new red fluorescent protein (DsRed) from the coral Discosoma sp. in conjunction with various combinations of three Aequorea victoria green fluorescent protein (GFP) variants--EYFP, EGFP, and ECFP. In spite of overlapping emission spectra, the combination of DsRed with EYFP, EGFP, and ECFP generated fluorescence signals that could be electronically compensated in real time using dual-laser excitation at 458 and 568 nm. Resolution of fluorescence signals from DsRed, EYFP, and EGFP was also readily achieved by single-laser excitation at 488 nm. Since many flow cytometers are equipped with an argon-ion laser that can be tuned to 488 nm, the DsRed/EYFP/EGFP combination is expected to have broad utility for facile monitoring of gene transfer and expression in mammalian cells. The dual-laser technique is applicable for use on flow cytometers equipped with tunable multiline argon-ion and krypton-ion lasers, providing the framework for studies requiring simultaneous analysis of four fluorescent gene products within living cells.  相似文献   

4.
Helium-neon lasers are economical and efficient light sources; their utility in flow cytometry to date has been limited by the lack of fluorescent probes that can be excited at 633 nm. Allophycocyanin (APC), a highly fluorescent phycobiliprotein, can be used as an antibody label and has spectral characteristics suitable for use with He-Ne lasers; we undertook to resolve whether a low-power (7 mW) He-Ne laser could provide sufficient excitation to permit flow cytometric detection of APC-labeled antibodies on cell surfaces. We made an APC conjugate of monoclonal antibody 4F2, which reacts with an antigen abundant on the surfaces of activated human T-lymphocytes; APC-4F2 was used to stain blood mononuclear cells that had been cultured with and without phytohemagglutinin (PHA). Cells so stained were examined in a flow cytometer with orthogonal illumination at 633 nm from a 7 mW He-Ne laser; antibody-bearing cells were detectable by fluorescence emission above 665 nm. Cells from the same cultures were stained with fluorescein-labeled 4F2 antibody and examined in a flow cytometer with argon ion laser excitation at 488 nm. Percentages of antibody-bearing cells determined from APC fluorescence and from fluorescein fluorescence were in good agreement. It thus appears that He-Ne lasers and APC-antibodies are usable for immunofluorescence measurements; the sensitivity attainable with this technique remains to be determined.  相似文献   

5.
In order to combine laser confocal microscopy with physiological measurements, a number of conditions have to be met: the dye must not be toxic to the cells the laser light itself must not damage the cells; and the excitation of the fluorochrome during imaging must not generate products with toxic effects. We have investigated these conditions the hearing organ of the guinea pig. Two dyes were used, namely, calcein-AM, which is metabolized in vital cells to a fluorescent product in the cytoplasm, and a lipophilic membrane dye. The effect of the dyes on cell function was tested in the intact hearing organ, maintained in the isolated temporal bone, by measuring the electrophysiological potentials generated by the sensory cells in response to tone pulses. The loading of the cells with the dyes had no adverse effects. The effect of the laser beam was explored on isolated coils from the cochlea. In two preparations, the specimens viewed in the confocal system were fixed and processed for electron microscopy. Identified cells were followed before, during, and after laser exposure and could ultimately be examined at the ultrastructural level. Exposure to the laser beam did not cause damage in unstained cells, even at high intensities. In stained tissue, confocal microscopy could safely be performed at normal beam intensity without causing ultrastructural changes. At high intensities, about 100 times normal for 60 times as long, irradiation damage was seen that was selective in that the cells stained with the different dyes exhibited damage at the different sites corresponding to the subcellular location of the dyes. Cells stained with calcein showed lysis of mitochondria and loss of cytoplasmic matrix, whereas cells stained with the styryl membrane dye showed swelling of subsurface cisternae, contortion of the cell wall, and shrinkage. The styryl dyes, in particular, which selectively stain the sensory and neuronal cells in the organ of Corti, could be exploited for phototoxic use.  相似文献   

6.
A high-resolution triple-laser sorter was designed and constructed to provide flexible switchover and high-resolution sorting of cells or chromosomes with any combination of one, two, or three lasers. These features provide a central facility instrument that currently serves multiple users and analyzes different stain combinations with minimal switchover effort between experiments. Improved optics and mounts that focus the three laser beams independently are able to resolve beads and chromosomes better than our previously reported dual-laser sorter. An improved signal collection unit with electronically controlled reference positions can be focused more quickly and precisely for any signal combination. A removable dye laser extends the range of usable fluorochrome labels. A rapid sheath switchover permits sorting of sterile cells and sterile chromosomes sequentially without additional sterilization or reservoir sheath change. Improved dual-laser chromosome resolution is at least as good, analyzing 8,000 chromosomes/s, compared to the previous dual-laser bench at 2,000/s. Stimulated and unstimulated peripheral blood lymphocytes were analyzed according to simultaneous measurements of cell surface receptors labeled with a fluoresceinated neuropeptide and a Texas red-labeled antibody as well as DNA content during the cell cycle. These results demonstrate the broad range of potential applications of this triple-laser system.  相似文献   

7.
A technique for rapid measurement of nuclear and cytoplasmic size relationships in mammalian cell populations has been developed. Based on fluorescence staining of either the nucleus alone or in combination with the cytoplasm using two-color fluorescence methods, this technique permits the simultaneous determination of nuclear and cytoplasmic diameters from fluorescence and light-scatter measurements. Cells stained in liquid suspension pass through a flow chamber at a constant velocity, intersecting a laser beam which excites cell fluorescence and causes light scatter. Depending upon which analysis procedure is used, optical sensors measure nuclear fluorescence and light scatter (whole cell size) or two-color nuclear and cytoplasmic fluorescence from individual cells crossing the laser beam. The time durations of signals generated by the nucleus and cytoplasm are converted electronically into signals proportional to the respective diameters and are displayed as frequency distribution hitograms. Illustrative examples of measurements on uniform microspheres, cultured mammalian cells and human exfoliated gynecologic cells are presented.  相似文献   

8.
H M Shapiro  S Stephens 《Cytometry》1986,7(1):107-110
The laser dyes oxazine 750 (OX750), LD700, and rhodamine 800 (R800) can be used in an instrument employing a low-power helium-neon laser source for flow cytometry of DNA content in ethanol-fixed or detergent-permeabilized cells. Cells in near-isotonic medium are stained with 10-30 microM dye, and fluorescence excited at 633 nm is measured at wavelengths above 665 nm. The dyes do not appear to stain RNA, and the intensity of DNA staining is not changed when 2 microM Hoechst 33342 is added to cells simultaneously with a red-excited dye. The effects on fluorescence of addition of DNA to LD700 or R800 in aqueous solution are strongly influenced by the base composition of the DNA; binding mechanisms remain to be determined.  相似文献   

9.
High gradient magnetic cell separation with MACS.   总被引:85,自引:0,他引:85  
A flexible, fast and simple magnetic cell sorting system for separation of large numbers of cells according to specific cell surface markers was developed and tested. Cells stained sequentially with biotinylated antibodies, fluorochrome-conjugated avidin, and superparamagnetic biotinylated-microparticles (about 100 nm diameter) are separated on high gradient magnetic (HGM) columns. Unlabelled cells pass through the column, while labelled cells are retained. The retained cells can be easily eluted. More than 10(9) cells can be processed in about 15 min. Enrichment rates of more than 100-fold and depletion rates of several 1,000-fold can be achieved. The simultaneous tagging of cells with fluorochromes and very small, invisible magnetic beads makes this system an ideal complement to flow cytometry. Light scatter and fluorescent parameters of the cells are not changed by the bound particles. Magnetically separated cells can be analysed by fluorescence microscopy or flow cytometry or sorted by fluorescence-activated cell sorting without further treatment. Magnetic tagging and separation does not affect cell viability and proliferation.  相似文献   

10.
OBJECTIVE: We evaluated the use of a high power, diode pulsed solid-state laser emitting 532 nm light for immunofluorescence applications. We compared the sensitivity and utility of this laser with the standard 488 nm excitation. METHODS: A flow cytometer was equipped with both a 488 nm and a 532 nm laser; fluorescence emissions from each laser were collected using the same filters and the same detector system. Cells or compensation beads (e.g. latex beads coated with anti-kappa antibodies) were stained with monoclonal antibodies conjugated to phycoerythrin (PE) as well as the PE tandem dyes TRPE, Cy5PE, Cy5.5PE, and Cy7PE. The sensitivity of detection of these reagents as well as those in heavily compensated channels was quantified by measuring the spreading error for a primary detector into a secondary detector. RESULTS: Measurement of the fluorescence emission of PE and PE-tandem dyes was considerably more sensitive when using 532 nm excitation (150 mW) as compared with 488 nm excitation (20 mW). In addition, as the absolute number of photoelectrons collected was greater, there was less measurement-error-induced spread into the compensated channels. As an example, when comparing the spreading error of PE labeled cells into the TRPE detector, the green laser was found to be 15-fold more sensitive as compared with the blue laser. In addition, the blue laser produced more autofluoresent signal from cells as compared with the green laser. Together, these advantages of the 532 nm excitation line provides for a significantly improved detection of immunofluorescence staining.  相似文献   

11.
BACKGROUND:The detection of DNA-incorporated bromodeoxyuridine (BrdUrd) in mammalian cells is a well-known and important technique to study cell cycle. The use of TO-PRO-3 for detection of BrdUrd substitution of DNA by dual-laser flow cytometry has been investigated. METHODS:Fluorescence enhancement of TO-PRO-3 in BrdUrd-labeled cells is registered in combination with the fluorescence emission of the intercalating dye propidium iodide (PI) as a total DNA stain to give bivariate DNA/BrdUrd histograms. By the low concentration of only 0.3 mircoM TO-PRO-3, BrdUrd detection is optimized, and undisturbed total DNA content by PI can be detected as well. TO-PRO-3 is excited by a red HeNe laser and PI by an argon ion laser. RESULTS:In order to understand the binding of TO-PRO-3, energy transfer from PI to TO-PRO-3 has been measured as well as the influence of an external DNA binding dye such as Hoechst 33258 with Adenine-Thymine (AT) binding specificity. Cell cycle studies of human SCL-2 keratinocytes and mouse 3T3 cells prove the method to be as generally applicable as the classical BrdUrd/Hoechst quenching technique, but without need for expensive ultraviolet laser excitation. No BrdUrd sensitivity could be found for the similar dyes TO-PRO-1 and YO-PRO-3, whereas TO-PRO-5 and YOYO-3 showed only very little sensitivity to BrdUrd labeling as compared with TO-PRO-3. CONCLUSIONS:Cell cycle studies of mammalian cells can be done by dual-laser flow cytometry without the need for ultraviolet lasers by using the BrdUrd-dependent fluorescence enhancement of TO-PRO-3. Total DNA content can be measured simultaneously using PI.  相似文献   

12.
By halogenation of methylfluorescein-diacetate (MFDA) or eosin-diacetate, two new dyes for cellular thiol compatible with visible laser excitation have become available. These probes circumvent the use of an ultraviolet (UV)-excitation system as required by bimane-based dyes and allow combination with probes for other cellular parameters. The thiol dyes attain maximal staining after 10 min at 37 degrees C, and fluorescence is sensitive to pretreatment with diethylmaleate but not to buthionine sulfoximine. In a dual-laser system, analysis of the cellular thiol level as a function of cell cycle distribution can be achieved in viable cells by simultaneous staining with the bisbenzimidazole dye Hoechst 33342 and one of the halogenated dyes. Using this approach, we were able to show that cells in the G2 phase of the cell cycle were more sensitive to thiol depletion with diethylmaleate than were cells in the G1 compartment. The new thiol dyes allow a more flexible selection of wavelengths of excitation and emission for assessing changes in cellular thiol (glutathione and other thiol compounds) and allow this parameter to be examined as a function of cell cycle position.  相似文献   

13.
Flow cytometry and fluorescence activated cell sorting techniques were designed to realize configurable classification and separation of target cells. A number of cell phenotypes with different functionalities have recently been revealed. Before simultaneous selective capture of cells, it is desirable to label different samples with the corresponding dyes in a multiplexing manner to allow for a single analysis. However, few methods to obtain multiple fluorescent colors for various cell types have been developed. Even when restricted laser sources are employed, a small number of color codes can be expressed simultaneously. In this study, we demonstrate the ability to manifest DNA nanostructure-based multifluorescent colors formed by a complex of dyes. Highly precise self-assembly of fluorescent dye-conjugated oligonucleotides gives anisotropic DNA nanostructures, Y- and tree-shaped DNA (Y-DNA and T-DNA, respectively), which may be used as platforms for fluorescent codes. As a proof of concept, we have demonstrated seven different fluorescent codes with only two different fluorescent dyes using T-DNA. This method provides maximum efficiency for current flow cytometry. We are confident that this system will provide highly efficient multiplexed fluorescent detection for bioanalysis compared with one-to-one fluorescent correspondence for specific marker detection.  相似文献   

14.
By use of a flow cytometer, the fluorescence of cells stained with hematoporphyrin derivative and the fluorescence of plastic beads stained with different dyes were analysed as a function of the intensity of the exciting laser light. The ratios of the fluorescence values of stained and unstained cells as well as of stained cells and beads were sensitively dependent on excitation intensities. As a consequence of this finding, the normalization of cellular fluorescence by use of reference particles needs to be made on a well-defined and reproduced intensity of the exciting laser light.  相似文献   

15.
Flow cytometers based on optical sensing utilize external light sources and fluorescent dyes to measure one or more specific components or properties of individual cells or subcellular particles in liquid suspension. To provide for independent excitation of two dyes used in double staining experiments we have constructed a high resolution flow cytometer that uses two laser beams to provide two wavelengths of excitation. These beams are separated spatially so that cells flow through them sequentially, with a time separation of about 20 musec. Since the dyes are excited sequentially their emission occurs at different times and their emission spectra may overlap without causing any difficulty in analysis. We have developed new light collection optics that permit up to four measurements to be made on each cell. This approach greatly increases the number of dye combinations that can be used in flow cytometry, thus removing a significant limitation of single illumination instruments.  相似文献   

16.
The automated high-speed analysis and separation of cells on the basis of spectroscopic parameters has been applied to studies of cellular differentiation in two systems. The temporal changes following induction of differentiation by dimethylsulfoxide in the Friend virus-transformed erythroid cells were quantitated by multiparameter analysis leading to the separation of discrete subpopulations. Thus, following induction, cell size decreased as measured by light scattering, the number of H-2 histocompatibility antigen sites decreased as measured by indirect fluorescent antibody binding, the number of lectin-binding sites per cell increased as measured by fluorescein-labeled concanavalin-A and the microviscosity of the hydrocarbon region of the plasma membrane increased as determined by the fluorescence emission anisotropy of the membrane probe 1,6-diphenyl-1,3,5-hexatriene. Cells were separated on the basis of several of these parameters and analyzed for their hemogloglobin content by benzidine staining. Examination of cells separated according to the anisotropy parameter showed that high anisotropy values were correlated with (a) small cell size, (b) positive staining with benzidine and (c) pronounced reactivity with fluorescent antibody to the erythrocyte protein spectrin. Disaggregated cells from Hydra attenuata were selectively stained with the dyes rhodanile blue, 7-(p-methoxybenzylamino)-4-nitrobenz-2-oxa-1,3-diazole and fluorescamine. Distribution analyses and preliminary separations indicated the feasibility of obtaining homogeneous classes of cell types in a viable state. The experiments with emission anisotropy represent the first analyses and separations of single cells on the basis of fluorescence polarization. Many other uses of this technique are anticipated.  相似文献   

17.
A technique for the detection of DNA damage induced by radiation insult has been developed. Cells were lysed with a buffer containing 2 M sodium chloride to release the DNA in a supercoiled form, the nucleoid. These were stained with the DNA intercalating dye, ethidium bromide, and exposed to laser light within a flow cytometer. Scattered and fluorescent light was analyzed from the laser/nucleoid interaction following irradiation of viable cells with gamma rays. The addition of ethidium bromide to prepared nucleoids caused a reduction in scattered light due to condensation of the nucleoid. Irradiation of cells prior to nucleoid production and ethidium bromide treatment restricted this condensation and produced a dose-dependent increase in laser scatter. Nucleoids derived from human lymphocytes showed enhanced light scatter from 5 Gy, compared to Chinese hamster ovary (CHO) fibroblasts where doses above 10 Gy were required. Up to 30 Gy CHO nucleoids showed a dose-dependent reduction in the ethidium bromide fluorescence. This technique allows detection of altered light scattering and fluorescent behavior of nucleoids after cellular irradiation; these may be related to structural changes within the nucleus induced by the radiation. The use of flow cytometry compared to other methods allows a rapid analysis of nuclear damage within individual cells.  相似文献   

18.
The principle of a multiple wavelength illumination method for flow cytometers, based upon a combination of a helium-neon laser and an arc lamp as illumination sources is described. By using a prism, the light from the arc lamp is dispersed and the different colors are imaged at different places on the sample stream. The small angle light scattering from the helium-neon laser light is measured as a relevant parameter and serves as a trigger signal for subsequent measurements of fluorescence or scattering of light from the arc lamp. Two experimental systems are described utilizing this principle: a system where the emission is detected orthogonally with respect to the direction of the illumination beams, and an epi-illumination system. With the orthogonal set-up multiple wave-length right angle scattering measurements are possible. This is illustrated by showing that the orthogonal scattering from erythrocytes is strongly dependent on the illumination wavelength. It is further shown that the apparatus is suitable for the measurement of intracellular pH using the pH dependence of the excitation spectrum of fluorescein. The epi-illumination system allows excitation of two (or more) fluorescent dyes with different excitation spectra. In this case the emission spectra of the fluorescent dyes may overlap substantially. This is shown by simultaneous measurement of DNA and protein of Chinese hamster lung cells using mitramycin and tetramethyl rhodamin isothiocyanate (TRITC).  相似文献   

19.
Colonies of a wild strain from Lake Burley-Griffin, Australia, of the hydrocarbon-producing green alga Botryococcus were examined by confocal laser scanning microscopy. The microscope was fitted with a dual wavelength krypton-argon laser, which permitted simultaneous detection of chlorophyll autofluorescence and lipophilic dye fluorescence. This quick and simple technique revealed the precise structural conformation of the autofluorescing plastids in living cells and their 3-dimensional spatial arrangement within the dense globular colonies. Cells stained with the lipophilic carbocyanine dye, DIOC6(3) contain an apical array of intensely staining granules as well as a more diffuse internal cisternal system thought to be endoplasmic reticulum. The cationic lipophilic dye rhodamine123 revealed a finer reticulate system in the outermost cytoplasm partially overlaying the plastid. Both dyes revealed the lipophilic nature of the extracellular matrix and enabled the secretion of lipid globules exuded from the colonies to be visualized. It is suggested that confocal laser scanning microcopy would make an ideal tool to screen isolates for their potential to form and secrete hydrocarbon, processes which are still far from clearly understood in this potentially commercially important alga. This revised version was published online in June 2006 with corrections to the Cover Date.  相似文献   

20.
Cells cultured on glass substrates have been investigated by phase contrast method. After freeze-thawing the same cells were stained for identification of damage by fluorescent dyes and studied by the phase contrast method, fluorescence and scanning electron microscopy. The method has revealed correlations between the damage of cell surface and the cell damage manifestation at morphological level.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号