首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for the analysis of tamoxifen and its metabolites in plasma from tamoxifen treated breast cancer patients, by capillary GC-MS using selected ion monitoring has been developed. Metabolite extraction was carried out on a Sep-pak C18 cartridge and metabolite purification by selective ion exchange chromatographic steps. Satisfactory recovery of radioactive standards through the extraction and purification steps was obtained. The method was shown to be accurate and precise with precision coefficient of variation values ranging from 4.3-11% for tamoxifen and its metabolites. Tamoxifen, 4-hydroxytamoxifen, metabolite Y and N-desmethyltamoxifen were identified with certainty in patient plasma on the basis of GC relative retention times and mass spectral comparison with authentic standards; because of their low abundance in plasma cis-metabolite E and 3,4-dihydroxytamoxifen could only be tentatively identified but identical GC behaviour and a satisfactory comparison of the abundance of key fragment ions was achieved. The tamoxifen and metabolite concentration ranges (ng X ml-1) in the group of patients who received 40 or 80 ng tamoxifen for 14 days were tamoxifen, 307-745; N-desmethyltamoxifen, 185-491; 4-hydroxytamoxifen, 1.4-2.5; 3,4-dihydroxytamoxifen, 0.7-2.0; metabolite Y, 19.0-112; and metabolite E1, 0.9-2.0.  相似文献   

2.
A rapid method for the determination of para-phenylenediamine (PPD) in cosmetic products, such as henna tattoos has been developed and evaluated. This analytical procedure involved extracting a 10mg test portion of cosmetic product in 10 mL of ethyl acetate, followed by determination by gas chromatography-mass spectrometry in the selected ion monitoring mode (GC/MS-SIM). 1,4-Phenylenediamine-2,3,5,6-d(4) was selected as an internal standard that was added at the beginning of the extraction procedure and used to correct for recovery and matrix effects. The linearity ranged from 1.0 to 1275 μg/mL with a coefficient of determination (r(2)) greater than 0.999. LOQ and LOD were 1.0 and 0.10 μg/mL, respectively. The recovery in a tattoo product containing PPD was 94% and that for a tattoo product containing no PPD reached 105%. Extraction efficiency of 98% was obtained. This method has been successfully applied to henna temporary tattoo and other henna-related cosmetic products for the determination and quantitation of PPD.  相似文献   

3.
Choi MH  Kim KR  Chung BC 《Steroids》2000,65(1):54-59
An efficient procedure is described for the simultaneous determination of 9 androgen glucuronides including androsterone, etiocholanolone, 11-ketoandrosterone, 11-ketoetiocholanolone, 11beta-hydroxyandrosterone, 11beta-hydroxyetiocholanolone, and dehydroepiandrosterone (DHEA) in 3-glucuronide form and dihydrotestosterone (DHT) and testosterone in 17-glucuronide form from urine specimens. The method involves solid-phase extraction of the urinary steroids using Serdolit PAD-1 resin, with subsequent conversion to methyl ester-trimethylsilyl (Me-TMS) ether derivatives for the direct analysis by gas chromatography-mass spectrometry (GC-MS) using high temperature MXT-1 (Silcosteel-treated stainless steel) capillary column. Upon split injection of Me-TMS steroids at 330 degrees C into the MXT-1 capillary column initially maintained at 300 degrees C then programmed to 322 degrees C at 2 degrees C/min, each androgen glucuronide was well separated in excellent peak shape. The characteristic ions at m/z 217 constituting the base peaks in the electron-impact (20 eV) mass spectra for most steroids permitted their sensitive detection by GC-MS with selected-ion monitoring (SIM), whereas base peak ion at m/z 271 was used for the SIM of dehydroepiandrosterone-3-glucuronide. The detection limits for SIM of most of the steroids were 15 pg except for the 3-glucuronides of 11-ketoandrosterone and 11-ketoetiocholanolone, which could be detected down to 20 pg. The SIM responses were linear with correlation coefficients varying from 0.981 to 0.993 in the concentration range of 20 to 3000 ng/ml for the androgens studied. When applied to urine samples, the present method allowed rapid screening for the 7 androgens in their glucuro-conjugated forms simultaneously with good overall precision and accuracy within the normal concentration ranges of 15.1 to 3124.6 ng/ml.  相似文献   

4.
A GC-MS (SIM) method has been developed which allows the measurement of tamoxifen and its metabolites in uterine cytosol and 0.5 M KCl-extracts of uterine nuclei from groups of immature rats. The method was shown to be specific, precise and accurate. Using this procedure tamoxifen and 4-hydroxytamoxifen were tentatively identified and measured in uterine extracts after tamoxifen administration. When tamoxifen and 4-hydroxytamoxifen levels in uterine cytosol and 0.5 M KCl nuclear extracts were compared a relative enrichment in the nuclear fraction of 4-hydroxytamoxifen (relative to tamoxifen) was consistently seen. These observations are supportive of a role for 4-hydroxytamoxifen in mediating the antiestrogenic actions of tamoxifen in the immature rat uterus. In some of the uterine cytosolic fractions desmethyltamoxifen and metabolite Y could also be detected.  相似文献   

5.
Tamoxifen, 4-hydroxytamoxifen and desmethyltamoxifen levels were measured in cytosolic and 0.5 M KCl extracted nuclear fractions from a small series of breast tumours from tamoxifen treated patients by gas chromatography-mass spectrometry (GC-MS) using selected ion monitoring (SIM). Tamoxifen and desmethyltamoxifen were the most abundant metabolites. There was a small increment in the relative abundance of 4-hydroxytamoxifen in the nuclear extract over cytosol relative to both tamoxifen and desmethyltamoxifen. Further, there was a selective retention of tamoxifen relative to desmethyltamoxifen in the nuclear extract relative to the cytosol. It is concluded that all three compounds could potentially contribute to estrogen receptor mediated antiestrogenic effects in this target tissue.  相似文献   

6.
7.
A method for the determination of dihydroetorphine hydrochloride, a powerful anaesthetic and analgesic drug, in biological fluids by GC-MS with selected-ion monitoring using etorphine as internal standard was established. Dihydroetorphine was extracted from human blood and urine with dichloromethane and then derivatized with N-heptafluorobutyrylimidazole after concentration to dryness. A dihydroetorphine monoheptafluorobutyl derivative was formed which showed good behavior on GC-MS with electronic-impact ionization. The main fragment, m/z 522, which is the base peak, was selected as the ion for quantitation and the corresponding ion, m/z 520, was selected for monitoring the internal standard, etorphine. The recoveries and coefficients of variation of the whole procedure were determined with five controlled dihydroetorphine-free urine and plasma samples spiked with different concentrations of dihydroetorphine. The concentration of dihydroetorphine for quantitation was in the range 1–20 ng/ml for urine and 2.5–250 ng/ml for plasma. The correlation coefficients of the standard curves are sufficient to determine the dihydroetorphine. The accuracy for quantitation of dihydroetorphine in urine and plasma is less than 10.6%.  相似文献   

8.
Leukotriene B4 (LTB4) is a potent chemotactic agent formed via the 5-lipoxygenase pathway from arachidonic acid. To understand the role LTB4 plays in several pathological processes it is essential that endogenous concentrations of LTB4 be accurately quantitated. We have developed a method based on electron capture negative ion mass spectrometry for the analysis of LTB4 in serum at low picogram per milliliter concentrations. Blood is collected into the 5-lipoxygenase inhibitor nordihydroguaiaretic acid (NDGA) to suppress ex vivo formation. Serum is isolated, equilibrated with the internal standard [2H4]LTB4, and extracted using octadecyl-silica (C-18) cartridges. After conversion of the carboxylic acids to their pentafluorobenzyl esters the extract is purified by straight-phase HPLC. Gas chromatographic-mass spectrometric analysis is accomplished on the tert-butyldimethylsilyl ether derivatives using dual-selected ion monitoring of m/z 431 and 435. These ions correspond to loss of tert-butyldimethylsilanol from the (M-PFB)- ion of endogenous and [2H4]LTB4, respectively. The concentration of LTB4 in human serum samples was 10.0 +/- 4.0 pg/ml (n = 5). The assay exhibited satisfactory precision, with an intraassay coefficient of variation of 17% and a high degree of accuracy. The concentration of LTB4 in serum collected with (NDGA) was less than 10% of that observed in blood collected without the lipoxygenase inhibitor. Ex vivo formation can therefore be a major obstacle in assessing circulating levels of LTB4.  相似文献   

9.
10.
An analytical protocol has been developed for the analysis of urinary 4-pyridoxic acid (4-PA) by gas chromatography—mass spectrometry (GC—MS) for use in metabolic studies. Aliquots of urine were deproteinised and fractionated by isocratic reversed-phase high-performance liquid chromatography. The eluent fraction containing the 4-PA was collected, freeze-dried and silylated using N-methyl-N-(tert.-butyldimethylsilyl)trifluoroacetamide. Derivatisation produced the mono-tert.-butyldimethylsilyl derivative of 4-PA lactone. This derivative was readily amenable to GC—MS analysis in the electron ionisation (70 eV) mode, yielding a prominent fragment ion at m/z 222 ([M — 57]+; base peak). A heavy isotope-labelled derivative of pyridoxine [dideuteriated pyridoxine; 3-hydroxy-4-(hydroxymethyl)-5-[hydroxymethyl-2H2]-2-methylpyridine] has been synthesised and is being employed to determine the kinetics of labelling of the body pools of vitamin B6. Kinetic measurements are based on the determination of the relative proportions of metabolically produced deuterium-labelled and non-labelled 4-PA in urine, obtained from stable isotope ratios determined by low-resolution selected ion monitoring using a bench-top quadrupole GC—MS system.  相似文献   

11.
4-Hydroxybutyric acid (4HB) was analyzed by gas chromatography-mass spectrometry. Under acidified conditions, 4HB is difficult to detect due to lactonization. Using a urine sample containing 0.01 mg creatinine, we performed trimethylsilyl derivatization without extraction, only adding dimethylsuccinic acid as an internal standard and 10 microl of 0.1 N NaOH methanol solution with adequate evaporation. Urine 4HB levels in a patient with 4-hydroxybutyric aciduria was determined to be 1258 mmol/mol Cr (control, 0.28-2.81 mmol/mol Cr) in this method. Direct derivatization of samples without extraction showed good reproducibility and linearity. Only a small sample of urine was required. Alkalinization by NaOH prevented not only lactonization of 4HB, but also loss of the compounds during evaporation.  相似文献   

12.
Phytosterols (beta-sitosterol, cholestanol and campesterol) and cholesterol precursors (desmosterol and lathosterol), have been suggested as important biochemical markers of intestinal cholesterol absorption and liver biosynthesis, respectively, and as useful clinical parameters in the study of hypercholesterolemia, beta-sitosterolemia, atherosclerosis and cardiovascular disease, including pharmacological response to hypolipidemic agents. We developed an optimised analytical method for the simultaneous analysis of cholestanol, desmosterol, lathosterol, campesterol and beta-sitosterol in plasma using capillary gas chromatography coupled to mass spectrometry (GC-MS) with multiple selected ion monitoring (SIM). This method is based on the alkaline hydrolysis of sterol esters, extraction of free sterols and derivatization. The recovery of all sterols was in the range 76-101%. Within-day relative standard deviations (R.S.Ds.) and the between-day R.S.Ds. of cholestanol, desmosterol, lathosterol, campesterol and beta-sitosterol were less than 8%, and their plasma levels in 161 normal subjects were (mean+/-S.D.) 4.73+/-2.57, 2.37+/-1.04, 6.23+/-3.14, 3.67+/-1.95 and 5.92+/-3.62 micromol/l, respectively.  相似文献   

13.
To diagnose inborn errors of metabolism, it would be desirable to simultaneously analyze and quantify organic acids, purines, pyrimidines, amino acids, sugars, polyols, and other compounds using a single-step fractionation; unfortunately, no such method currently exists. The present article will be concerned primarily with a practical yet comprehensive diagnostic procedure of inborn errors of metabolism (IEM). This procedure involves the use of urine or eluates from urine on filter paper, stable isotope dilution, and gas chromatography-mass spectrometry (GC-MS). This procedure not only offers reliable and quantitative evidence for diagnosing, understanding and monitoring the diseases, but also provides evidence for the diagnosis of new kinds of IEM. In this review, the differential diagnosis for hyperammonemia are described; deficiencies of ornithine carbamoyl transferase, argininosuccinate synthase (citrullinemia), argininosuccinate lyase and arginase, lysinuric protein intolerance, hyperammonemia-hyperornithinemia-homocitrullinemia syndrome, and citrullinemia type II. The diagnosis of IEM of purine and pyrimidine such as deficiencies of hypoxanthine-guanine phosphoribosyl transferase, adenine phosphoribosyl transferase, dihydropyrimidine dehydrogenase, dihydropyrimidinase and beta-ureidopropionase are described. During the pilot study for newborn screening, we found neonates with diseases at a rate of 1 per 1,400 including propionic acidemia, methylmalonic acidemia, orotic aciduria, beta-ureidopropionase deficiency, lactic aciduria and neuroblastoma. A rapid and reliable prenatal diagnosis for propionic acidemia is also described.  相似文献   

14.
A rapid screening procedure is described for the simultaneous determination of various acidic non-steroidal anti-inflammatory drugs (NSAIDs) at sub-nanogram levels. The procedure involves solid-phase extraction (SPE) of NSAIDs using Chromosorb P as the adsorbent in partition mode, with subsequent single-step conversion to tert.-butyldimethylsilyl (TBDMS) derivatives, followed by direct analysis by gas chromatography-mass spectrometry (GC-MS). The characteristic [M−57]+ high-mass ions constituting the base peaks in the electron-impact mass spectra of most TBDMS derivatives permitted sensitive detection of NSAIDs by GC-MS in selected-ion monitoring (SIM) mode, even in the presence of higher levels of coextracted urinary organic acids. The detection limit for SIM of each drug was in the range 0.03–0.9 pg. When applied to urine samples (250 μl) spiked with NSAIDs, the present GC-SIM-MS method allowed simultaneous screening for various NSAIDs with good overall precision and accuracy in the range of 10–40 ng.  相似文献   

15.
We used gas chromatography-mass spectrometry to assay putrescine in minute regions of single rat brains. Acid extraction, partial purification on Amberlite CG 120, and derivatization with pentafluoropropionic anhydride preceded the gas chromatography-mass spectrometry. A moving-needle solventless system and a direct inlet system were also used to increase sensitivity. Putrescine was measured accurately at the picomole level; the mean concentration of this polyamine in five regions of rat brain found by this method was 2.7-3.8 times higher than reported by other researchers.  相似文献   

16.
The structural elucidation of metabolites of penehyclidine in rats, a novel anti-cholinergic drug, by the method of liquid chromatography-electrospray ionization mass spectrometry, gas chromatography-mass spectrometry with electron impact ion source and stable isotope ion cluster was described. Identification and elucidation of the phase I and phase II metabolites were performed by comparing the daughter ion pairs of stable isotope cluster, changes of the protonated molecular masses, full scan MS(n) spectra and retention times with those of the parent drug, penehyclidine and penehyclidine deuterium-labeled. Penehyclidine was easily biotransformed by the pathways of oxidative, hydroxylated, methoxylated and phase II conjugated reactions to form several metabolites that retained the some features of the parent molecules. Twelve metabolites (penehyclidine monoxide, hydroxypenehyclidine, penehyclidine dioxide, hydroxypenehyclidine monoxide, dihydroxypenehyclidine, dihydroxypenehyclidine (position isomer), dihydroxypenehyclidine monoxide, trihydroxypenehyclidine, methoxypenehyclidine dioxide, dimethoxypenehyclidine, trihydroxymethoxypenehyclidine and glucuronide conjugated hydroxypenehyclidine) were identified. The results from electrospray ion and electron impact ion data with the stable isotope cluster showed the qualitative differences in the mass spectral patterns, suggesting that these technologies should be used in parallel to ensure comprehensive metabolites detection and characterization. The described method has wide applicability to rapidly screen and provide structural information of metabolites.  相似文献   

17.
Analysis of trimethyl carboxyphosphate samples by gas chromatography-mass spectrometry, using typical conditions resulted in significant decomposition of the analyte. Optimization of injection conditions, including conditioning of the injection port liner, produced a dramatic increase in observed peak areas and afforded an effective method for detection of trimethyl carboxyphosphate at the <1μg mL−1 level.  相似文献   

18.
The determination of ethambutol in plasma is described. Using ethambutol-d4 as an internal standard, ethambutol and the internal standard were extracted with chloroform under alkaline conditions, and converted into their trifluoroacetyl derivatives with trifluoroacetic anhydride in benzene-pyridine (4:1). Selected ion monitoring was carried out by monitoring the peaks at 294 and 296 corresponding to the fragment ion [ ]+ of the derivatives. Ethambutol was determined by use of the peak height ratio of the peak at 294 against that at 296.The method was utilized successfully for studying the bioavailability and pharmacokinetics of the drug.  相似文献   

19.
20.
It has been reported (Poston, J. (1976) J. Biol. Chem. 251, 1859-1863; (1982) 255, 10067-10072; (1984) 259, 2059-2061) that mammalian tissues contain an adenosylcobalamin-dependent enzyme, leucine 2,3-aminomutase, which catalyzes the interconversion of beta-leucine and leucine. It was also reported that beta-leucine is detectable in normal human serum (mean = 4.8 mumol/liter, n = 37) and is elevated in serum from patients with cobalamin deficiency (mean = 24.7 mumol/liter, n = 17). Serum levels of leucine were claimed to be decreased in the cobalamin deficient patients (mean = 52 mumol/liter) as compared with the normal subjects (mean = 81 mumol/liter). It was also reported that rat liver supernatant catalyzed the formation of beta-leucine, leucine, or both amino acids from iso-fatty acids, and that the generation of leucine from iso-fatty acids was stimulated by adenosylcobalamin and inhibited by unsaturated cobalamin-binding protein. We have synthesized t-butyldimethylsilyl derivatives of beta-leucine and leucine and have used capillary gas chromatography-mass spectrometry for their analysis. Using forms of beta-leucine and leucine that contain several deuterium atoms in place of several hydrogen atoms as internal standards, techniques have been developed which make it possible to detect and quantitate as little as 0.1 mumol/liter of beta-leucine or leucine in human serum and in incubations containing rat liver supernatant. beta-Leucine was not detectable, i.e. less than 0.1 mumol/liter, in any sera from 50 normal human subjects or in any sera from 50 cobalamin-deficient patients. The mean level of leucine in the 50 cobalamin-deficient sera was 219 mumol/liter, which was not decreased with respect to that in the 50 control sera (167 mumol/liter). Experiments in which beta-leucine, leucine, isostearic acid, or isocaproic acid were incubated with rat liver supernatant in the presence or absence of adenosylcobalamin or cobalamin-binding protein failed to demonstrate the formation of leucine or beta-leucine or their interconversion under any of the conditions studied. We conclude that beta-leucine is not present in human blood and that the existence of leucine 2,3-aminomutase in mammalian tissues remains to be established.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号