首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Soluble Antigen Fluorescent-Antibody Technique   总被引:3,自引:2,他引:1       下载免费PDF全文
An indirect fluorescent-antibody (FA) procedure employing soluble antigen fixed onto an artificial matrix was developed, and a mechanical means for reading of test results was devised. The method employs two small cellulose acetate paper discs for each test. One disc contains soluble antigen diluted in 1% bovine serum albumin (BSA); the other contains only 1% BSA and serves as a control. After testing by the indirect FA procedure, the results of the tests are read on a fluorometer fitted with a paper chromatogram door. The instrument is set at zero with the control disc as a blank, and the specific fluorescence of the antigen disc is determined. Findings obtained with homologous and heterologous antisera indicated that the method yields excellent results. The soluble antigen fluorescent-antibody technique has definite advantages over the conventional indirect FA procedures. (i) The investigator may objectively select the antigen to be employed. (ii) It is possible to obtain objective mechanical reading of test results rather than the highly subjective readings required by conventional methods. (iii) The system compensates for any nonspecific fluorescence contributed either by the serum (e.g., drugs) or by free fluorescein in the conjugated antiserum.  相似文献   

2.
The indirect fluorescent-antibody technique was used to assess a rapid method for identification of amoebae belonging to the genus Naegleria. Thirty-eight Naegleria and eight other limax amoeba strains were examined by using one N. gruberi and two N. fowleri antisera. All pathogenic Naegleriae, most of which originated from fatal cases of primary amoebic meningo-encephalitis, were identified as belonging to the fowleri species. Most of the N. gruberi strains showed irregular fluorescence. Other limax amoebae, such as Vahlkampfia, Acanthamoeba, Hartmannella, and Schizopyrenus sp. gave negative responses with the prepared antisera. The indirect fluorescent-antibody technique allows the identification of N. fowleri in a mixed culture of both N. fowleri and N. gruberi strains. Twenty-two Naegleria isolated from a suspected stream, other surface waters, and muddy soil could be excluded from the fowleri species with the indirect fluorescent-antibody technique. The results obtained demonstrate that this immunological technique is a valid method for the rapid identification of N. fowleri trophozoites.  相似文献   

3.
The feasibility of automating the decision-making tasks of the medical technician in the determination of the results of the indirect fluorescent-antibody test for toxoplasmosis was investigated. Two approaches were studied: (i) macroscopic measurement of fluorescence from a large number of organisms (full-field illumination measurements), and (ii) microscopic measurements of fluorescence and morphology of individual parasites (pattern recognition). The macroscopic approach was studied utilizing an argon-ion laser in incident illumination with a Leitz Ortholux microscope and a phototube mounted so as to measure green fluorescence. Due to similar amounts of fluorescence from negative polar reactions and positive rim reactions, the macroscopic technique was concluded to be not feasible. The microscopic approach was studied utilizing a high resolution optical pattern recognition instrument. The results indicate that an object area measurement is sufficient to distinguish the presence of Toxoplasma gondii organisms from debris and overlapping organisms when studying the red fluorescence (due to Evans blue counterstain). Dark reactions were determined by the absence of green fluorescence. The differentiation of the rim and polar reactions was determined by the measurement of the ratio of green fluorescing area (due to fluorescein isothiocyanate) to red fluorescing area on the same organism. Clinically important titer information was also demonstrated to be obtainable. It was concluded that complete automation of the indirect fluorescent antibody test for toxoplasmosis is feasible with existing technology.  相似文献   

4.
5.
Platelet function has been studied in 16 patients with uncomplicated infectious mononucleosis. Some abnormality of platelet aggregation and/or release of platelet factor III or platelet factor IV was found in all patients. Six patients with platelet defects were retested after three to four months and were found to have normal platelet function and appreciably higher platelet counts. Abnormal platelet function may reflect a platelet defect which predisposes to premature platelet destruction. Recent viral illness should be excluded before attributing abnormal platelet function to other factors or to a congenital disorder.  相似文献   

6.
7.
The indirect fluorescent-antibody technique was employed in an attempt to develop a rapid method of identification of Corynebacterium vaginale. Six reference strains and ten clinical isolates selected on the basis of morphology and conventional biochemical tests were compared. Antisera were prepared in rabbits against the six reference strains. The most satisfactory antiserum was that prepared using strain 14018 grown diphasically (14018 Di) as the antigen. Certain of the antisera did exhibit a cross-reacting titer when reacted against Corynebacterium diptheriae, Corynebacterium xerosis, or Lactobacillus acidophilus. However, antisera adsorbed with these bacteria did not exhibit a significant decrease in titer when reacted against the homologous strain. Various other species of Corynebacterium as well as species of Nocardia, Actinomyces, Hemophilus, and Streptococcus did not fluoresce with the antisera. A specific antiserum was prepared by adsorbing anti-14018 Di with L. acidophilus. The adsorption removed the cross-reacting antibody but did not affect the staining reaction with C. vaginale strains. All reference strains and clinical isolates characterized as C. vaginale gave a definite positive reaction with the adsorbed anti-14018 Di. The specificity of the reactions was assessed by adsorbing the antiserum with the homologous strain. The data suggest that the indirect staining method will be of value in the rapid presumptive identification of C. vaginale.  相似文献   

8.
9.
10.
11.
12.
13.
14.
15.
16.
An evaluation of the newly developed Clinical Sciences, Inc. Salmonellae Fluoro-Kit, which attempts to standardize the various aspects of the fluorescent-antibody (FA) procedure, was performed with 120 naturally contaminated human food, animal feed, and raw material samples. The Association of Official Analytical Chemists (AOAC) method for the detection of salmonellae was used as the control method. The Fluoro-Kit was found to be simple and conveniento to use. The results of this preliminary study show an industrially acceptable rate of recovery of salmonellae by using the Fluoro-Kit in comparison with the A.O.A.C. method. The Fluoro-Kit shows promise as a rapid, salmonellae FA screening method. Problems originally encountered in the application of the Fluoro-Kit are discussed. According to the manufacturer, strict adherence to the now revised procedures included in the Fluoro-Kit will control these problems.  相似文献   

17.
The value of various serological tests in the diagnosis of paracoccidioidomycosis was studied. Quantitative agar-gel immunodiffusion and indirect immunofluorescent tests were performed, and the results were compared with those of complement fixation and qualitative agar-gel procedures. The quantitative immunodiffusion procedure was found to serve as the simplest and safest quantitative test that could be performed for evaluation purposes, whereas the indirect fluorescent-antibody test gave nonspecific reactions and, as such, proved unsuitable.  相似文献   

18.
From 44 to 100% of sera from patients with infectious mononucleosis exhibited the capacity to stimulate colony formation in vitro by mouse bone marrow cells. The proportion of sera with colony-stimulating activity was highest in patients with a short fever period and developing low Paul-Bunnell titres. Patients with a more severe course of the disease generally displayed no, or only weak, colony-stimulating activity in their sera, and also had higher Paul-Bunnell titres. The level of serum colony-stimulating activity tended to fall in the convalescent stages of the disease.  相似文献   

19.
Agglutination and fluorescent-antibody methods were employed for screening Clostridium perfringens types C and D from 393 isolates of this organism. All of 50 strains which were isolated in Japan and were agglutinable with an antiserum prepared against a stock strain of type C no. 3182 toxigenically belonged to type C, but the antiserum showed no cross-agglutination with any of type C strains isolated in Denmark. All of the latter strains, however, were agglutinated by an antiserum prepared against a Danish strain, CWC11. Of 64 strains, showing heat-labile agglutinability by type D antiserum L9, 22 strains were toxigenically identified as type D strains which can be divided into three groups by the heat-stable antigens; no strains which were L-agglutination-positive but O-agglutination-negative were epislon-toxigenic. All of 13 strains, the heat-stable antigen of which was agglutinable by a type D antiserum VX81, were toxigenically type D strains. The results of fluorescent-antibody tests were almost in agreement with those of agglutination test with type C strains and completely with those of the O-agglutination test with type D strains. No beta-, epsilon- or delta-toxigenicity could be demonstrated in strains which were not agglutinated by our test sera for types C and D strains. Further examination of cultural properties of Japanese and Danish type C strains revealed that the two groups were considerably different in urease production, capsule formation, and delta- and alpha-toxigenicities.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号