首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple, rapid and sensitive liquid chromatography/tandem mass spectrometric (LC/MS/MS) analytical method was developed for quantification of Hsp90 inhibitor PF-04928473 in human plasma, following administration of its prodrug, PF-04929113. Sample processing involved protein precipitation by addition of 0.4 mL of methanol containing internal standard (PF-04972487) to 50 μL volume of plasma sample. Chromatographic separation of PF-04928473 and PF-04972487 was achieved on a Phenomenex® Luna C18(2) (2.0mm × 50 mm, 5 μm) column using a gradient elution method with mobile phase solvents: methanol containing 0.1% formic acid and 0.1% formic acid at a flow rate of 0.25 mL/min. Detection was performed in electrospray positive ionization mode, monitoring the ion transitions from m/z 465.1 → 350.1 (PF-04928473) and m/z 447.0 → 329.1 (PF-04972487). The retention times for PF-04928473 and PF-04972487 were 1.86 and 2.85 min, respectively. Calibration curves were generated in the range of 2–2000 ng/mL. The accuracy and precision ranged from 94.1 to 99.0% and 86.7 to 97.6%, respectively, which were calculated using quality control samples of three different concentrations analyzed in quintuplicate on four different days.  相似文献   

2.
Orally administered racecadotril is rapidly hydrolyzed to the more potent enkephalinase inhibitor thiorphan in vivo. A sensitive and specific liquid chromatography/tandem mass spectrometry method was developed and validated to quantify thiorphan in human plasma using lisinopril as the internal standard. After a simple protein precipitation with methanol, the post-treatment samples were analyzed on a CN column interfaced with a triple-quadruple tandem mass spectrometer using negative electrospray ionization. The method was validated to demonstrate the specificity, lower limit of quantification, accuracy, and precision of measurements. The assay was linear over the concentration range 9.38-600 ng/mL using a 5 microL aliquot of plasma. The correlation coefficients for the calibration curves ranged from 0.9985 to 0.9995. The intra- and inter-day precisions over the entire concentration were not more than 6.33%. Methanol and water (35:65, v/v) is used as the isocratic mobile phase, with 0.1% of formic acid in water. The method was successfully applied for pharmacokinetic study after a single oral administration of 200 mg racecadotril to 20 healthy volunteers.  相似文献   

3.
A sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of erucylphosphohomocholine (erufosine, ErPC(3)) in pharmacokinetic studies. Nine-fold deuterated ErPC(3) was used as the internal standard. Following protein precipitation, reversed phase chromatography was performed. For analyte detection, electrospray ionization in the positive mode was applied. The mass transition m/z 504.4>139.1 was recorded for ErPC(3), and the transition m/z 513.7>139.1 for the internal standard, respectively. Good linearity with a correlation coefficient >0.99 was found for the range of 0.48-15 mg/L ErPC(3) in plasma (0.93-29.8 microM), the important range for clinical pharmacokinetic analysis. Interassay coefficients (n=10) of variation between 4.2% and 5.5% were found for ErPC(3) pool samples with concentrations between 4.7 mg/L and 44.0mg/L, respectively. The method has been used for analyses during a phase I clinical trial of ErPC(3).  相似文献   

4.
A sensitive and specific method using a one-step liquid-liquid extraction (LLE) with ethyl acetate followed by high-performance liquid chromatography (HPLC) coupled with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed and validated for the determination of roxatidine in human plasma using famotidine as an internal standard (IS). Data acquisition was carried out in multiple reaction monitoring (MRM) mode, by monitoring the transitions m/z 307.3-->107.1 for roxatidine and m/z 338.4-->189.1 for famotidine. Chromatographic separation was performed on a reverse phase Hydrosphere C(18) column at 0.2 mL min(-1) using a mixture of methanol-ammonium formate buffer as mobile phase (20:80, v/v; adjusted to pH 3.9 with formic acid). The achieved lower limit of quantification (LLOQ) was 1.0 ng mL(-1) and the standard calibration curve for roxatidine was linear (r(2)=0.998) over the studied range (1-1000 ng mL(-1)) with acceptable accuracy and precision. Roxatidine was found to be stable in human plasma samples under short-, long-term storage and processing conditions. The developed method was validated and successfully applied to the bioequivalence study of roxatidine administrated as a single oral dose (75 mg as roxatidine acetate hydrochloride) to healthy female Korean volunteers.  相似文献   

5.
A sensitive method using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) was developed and validated for the analysis of antihistamine drug azatadine in human plasma. Loratadine was used as internal standard (IS). Analytes were extracted from human plasma by liquid/liquid extraction using ethyl acetate. The organic phase was reduced to dryness under a stream of nitrogen at 30 °C and the residue was reconstituted with the mobile phase. 5 μL of the resulting solution was injected onto the LC-MS/MS system. A 4.6 mm × 150 mm, I.D. 5 μm, Agilent TC-C(18) column was used to perform the chromatographic analysis. The mobile phase consisted of ammonium formate buffer 0.010 M (adjusted to pH 4.3 with 1M formic acid)/acetonitrile (20:80, v/v) The chromatographic run time was 5 min per injection and flow rate was 0.6 mL/min. The retention time was 2.4 and 4.4 min for azatadine and IS, respectively. The tandem mass spectrometric detection mode was achieved with electrospray ionization (ESI) iron source and the multiple reaction monitoring (MRM) (291.3 → 248.2m/z for azatadine, 383.3 → 337.3m/z for IS) was operated in positive ion modes. The low limit of quantitation (LLOQ) was 0.05 ng/mL. The intra-day and inter-day precision of the quality control (QC) samples was 8.93-11.57% relative standard deviation (RSD). The inter-day accuracy of the QC samples was 96.83-105.07% of the nominal values.  相似文献   

6.
High-performance liquid chromatography with on-line electrospray ionization mass spectrometry (ESI-LC/MS) was investigated for the analysis of carbohydrate heterogeneity using RNase B as a model glycoprotein. Oligosaccharides released from RNase B with endoglycosidase H were reduced and separated on a graphitized carbon column (GCC). GCC-HPLC/MS in the positive-ion mode was successful in the identification of one Man5GlcNAc, three Man6GlcNAc, three Man7GlcNAc, three Man8GlcNAc, one Man9GlcNAc, and an oligosaccharide having six hexose units (Hex) and two N-acetylhexosamine units (HexNAc). The branch structures of the three Man7GlcNAc isomers were determined by liquid chromatography with tandem mass spectrometry (LC/MS/MS). LC/MS/MS analysis was shown to be useful for the detection and identification of a trace amount of Hex6HexNAc2 alditol as a hybrid-type oligosaccharide. Its structure was confirmed by the combination of LC/MS with enzymatic digestion using beta-galactosidase and N-acetyl-beta-glucosaminidase. The relative quantities of high-mannose-type oligosaccharides in RNase B detected by ESI-LC/MS are in reasonable agreement with those by UV, high-pH anion-exchange chromatography with pulsed amperometric detection, fluorophore-assisted carbohydrate electrophoresis. Our results indicate that LC/MS and LC/MS/MS can be utilized to elucidate the distribution of oligosaccharides and their structures, which differ in molecular weight, sugar sequence, and branch structure.  相似文献   

7.
5-Azacytidine (5AC), a nucleoside analogue and hypomethylating agent, has anticancer properties and has been utilized in the treatment of various malignancies. 5AC is unstable and rapidly hydrolyzed to several by-products, including 5-azacytosine and 5-azauracil. A sensitive, reliable method was developed to quantitate 5AC using LC/MS/MS to perform pharmacokinetic and pharmacodynamic studies on 5AC combination therapy trials. Blood samples were collected in a heparinized tube and immediately processed for storage. To increase the stability of 5AC in plasma, 25 ng/mL tetrahydrouridine was added to the plasma and snap frozen. Plasma samples were extracted using acetonitrile then cleaned up by Oasis MCX ion exchange solid-phase extraction cartridges. 5AC was separated on an YMC Jsphr M80 C(18) column with gradient elution of ammonium acetate (2 mM) with 0.1% formic acid and methanol mobile phase. 5AC elutes at 5.0 +/- 0.2 min with a total run time of 30 min. Identification was through positive-ion mode and multiple reaction monitoring mode at m/z+ 244.9-->113.0 for 5AC and m/z+ 242.0-->126.0 for 5-methyl-2'-deoxycytidine, the internal standard. The lower limit of quantitation of 5AC was 5 ng/mL in human plasma, and linearity was observed from 5 to 500 ng/mL fitted by linear regression with 1/x weight. This method is 50 times more sensitive than previously published assays and successfully allows studies to characterize the pharmacokinetics and pharmacodynamics of 5AC.  相似文献   

8.
Yeo S  Roh GS  Kim DH  Lee JM  Seo SW  Cho JW  Kim CW  Kwack K 《Proteomics》2004,4(11):3308-3317
Asthma is increasing in prevalence worldwide as a result of factors associated with a Western lifestyle. However, simple and reliable diagnostic and prognostic markers are yet to be found. In an attempt to identify protein biomarker profiles among small molecular weight ranges, we employed an approach combining liquid chromatography with mass spectrometry, instead of two-dimensional gel electrophoresis (2-DE), which has previously been used to analyze protein expression patterns. Here we described its application to compare plasma peptides from control and chronic asthma mice. Peptides were quantitatively profiled as a multidimensional peptide mass fingerprint by a combination of reverse-phase high-performance liquid chromatography and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. They were identified by peptide mass fingerprinting using matrix-assisted laser desorption/ionization time-of-flight/time-of-flight tandem mass spectrometry. In this study, we quantitatively identified the fragment f of complement 3 (C3f), which is important in inflammation. C3f was significantly higher in controls than chronic asthma mice. Our strategy allowed the detection and identification of different plasma peptides between control and chronic asthma mice on a proteomic scale. Therefore, these results suggest that native small peptides detected by non-2-DE techniques may be useful and specific biomarkers of disease.  相似文献   

9.
A rapid, sensitive, robust and specific method was developed for the determination and quantitation of felodipine, in human blood plasma by liquid chromatography coupled with tandem mass spectrometry using nimodipine as internal standard. Felodipine was extracted from 0.5 mL human plasma by use of a liquid/liquid procedure using diethyl ether/hexane (80/20, v/v) as eluent. The method included a chromatographic run of 5 min using a C(18) analytical column (100 mm x 4.6 mm i.d.) and the calibration curve was linear over the range from 0.02 to 10 ng mL(-1) (r(2) > 0.994). The between-run precision, determined as relative standard deviation of replicate quality controls, was 5.7% (0.06 ng mL(-1)), 7.1% (0.6 ng mL(-1)) and 6.8% (7.5 ng mL(-1)). The between-run accuracy was +/- 0.0, 2.1 and 3.1% for the above-mentioned concentrations, respectively.  相似文献   

10.
Sepsis is a systemic, often fatal inflammatory response whose biochemical pathways are not fully understood and with no single biomarker capable of its reliable prediction. Increased interest in protein profiling to reveal fundamental biochemical events as well as disease diagnosis has grown considerably, largely due to advances in mass spectrometry and related front-end technologies. In this study, patients with sepsis and systemic inflammatory response syndrome (SIRS) were examined using plasma protein profiling following immunodepletion treatment to remove the most abundant proteins, serum albumin, transferrin, haptoglobin, anti-trypsin, IgG, and IgA. These proteins cause significant signal suppression, and their removal allows for lower abundance proteins to be examined through improved ion signal. Analyses after immunodepletion were performed using 3-dimensional reverse phase/strong cation exchange/reverse phase liquid chromatography with electrospray ion trap mass spectrometry (3D LC-MS/MS) and spectrum counting for comparative quantitation. The results revealed a major theme in immune system activity, including activation of the complement and coagulation pathways. Additionally, lipid transport may prove to be important in distinguishing sepsis from SIRS. Specifically, significant multi-fold changes were observed in 10 proteins and are now being investigated for the early diagnosis of sepsis.  相似文献   

11.
A method has been developed and validated for the quantitation of midazolam, alphahydroxy-midazolam, omeprazole, and hydroxyomeprazole from one 250 microL sample of human plasma using high performance liquid chromatography coupled to tandem mass spectrometry. The method was validated for a daily working range of 0.400-100 ng/mL, with limits of detection between 2 and 15 pg/mL. The inter-assay variation was less than 15% for all analytes at four control concentrations and the samples were stable for three freeze-thaw cycles under the analysis conditions and 24 h in the post-preparative analysis matrix. This method was used to analyze samples in support of clinical studies probing the activity of the cytochrome P-450 enzyme system.  相似文献   

12.
A simple offline LC–MS/MS method for the quantification of sitagliptin in human plasma is described. Samples are prepared using protein precipitation. Filtration of the supernatants through a Hybrid-SPE-PPT plate was found to be necessary to reduce ionization suppression caused by co-elution of phospholipids with sitagliptin. The sitagliptin and its stable isotope labeled internal standard (IS) were chromatographed under hydrophilic interaction chromatography conditions on a Waters Atlantis HILIC Silica column (2.1 mm × 50 mm, 3 μm) using a mobile phase of ACN/H2O (80/20, v/v) containing 10 mM NH4Ac (pH 4.7). The sample drying after protein precipitation due to high organic content in the sample is not necessary, because HILIC column was used. The analytes were detected with a tandem mass spectrometer employing a turbo ion spray (TIS) interface in positive ionization mode. The multiple reaction monitoring (MRM) transitions were m/z 408 → 235 for sitagliptin and m/z 412 → 239 for IS. The lower limit of quantitation (LLOQ) for this method is 1 ng/mL when 100 μL of plasma is processed. The linear calibration range is 1–1000 ng/mL for sitagliptin. Intra-day precision and accuracy were assessed based on the analysis of six sets of calibration standards prepared in six lots of human control plasma. Intra-day precision (RSD%, n = 6) ranged from 1.2% to 6.1% and the intra-day accuracy ranged from 97.6% to 103% of nominal values.  相似文献   

13.
An HPLC assay with tandem mass spectrometric detection in the positive-ion Turbo-Ion-Spray (TISP) mode for the fast and sensitive determination of perifosine ((I), D-21266) in human plasma was developed, utilising the structural analogue, miltefosine ((II), D-18506), as internal standard. Automated solid-phase extraction of diluted plasma samples, based on 250-μl plasma aliquots, at pH 6.5, allowed a reliable quantification of perifosine down to 4 ng/ml. Injection of 200 μl of plasma extracts onto a 100×3 mm normal-phase analytical column at a flow-rate of 0.5 ml/min provided retention-times of 2.4 and 2.1 min for perifosine (I) and the internal standard (II), respectively. The standard curves were linear from 4 to 2000 ng/ml using weighted linear regression analysis (1/Y2). The inter-assay and intra-assay accuracies for the calibration standards were within +0.9% and −0.2%, exhibiting precisions (C.V.) of ±6.5 and ±7.3%, respectively. Up to 100 unknowns may be analysed each 24 h per analyst.  相似文献   

14.
An HPLC-MRM-MS method was developed for the quantification of 17 small ACE inhibiting (ACEI) peptides in plasma samples collected from human volunteers after the consumption of a peptide-enriched drink. The assay shows the high selectivity and sensitivity necessary to monitor small changes in the levels of the ACEI peptides after consumption of drinks developed to effect lowering of the blood pressure. Four different sample preparation methods were tested and evaluated. The final sample preparation method selected is simple and effective and consists mainly of the removal of proteins by acidification and heating, followed by a large volume injection. Additional sample preparation steps such as solid phase extraction and liquid/liquid partitioning were studied. Although they resulted in cleaner extracts, losses of specific peptides such as SAP were frequently seen. The isotope labeled form of one of the peptides to be quantified, [U(13)C]IPP, was used as an internal standard. The limit of detection of the assay is below 0.01 ng ml(-1). The limit of quantification is between 0.05 and 0.2 ng ml(-1), which is approximately 10% of the expected peptide concentration in plasma based on a normal diet. The intra- and inter-day relative standard deviations for all peptides have shown to be below 25% and the method has an accuracy of better than 75%. The long-term stability is good. At least 200 samples could be analysed before the system had to be cleaned. The assay has been successfully applied to blood samples collected from volunteers during a human trial.  相似文献   

15.
One of the major challenges facing protein analysis is the dynamic range of protein expression within massively complex samples (Corthals, G. L. et al.., Electrophoresis 2000, 21, 1104-1115). In plasma this difference is as great as ten orders of magnitude, and this is currently beyond the range of detection achievable by any of the analytical techniques. Plasma has the additional challenge of having a few highly abundant proteins, such as albumin, which mask the detection of lower abundance and biologically significant proteins. The use of the Gradiflow BF400 as a fractionation tool to deplete highly abundant albumin from human plasma is reported here. A sequential three-step protocol was performed on five plasma samples as part of the International Plasma Proteome Project organised by the HUPO; four containing different anticoagulants: EDTA, citrate, heparin and a control sample (NIBSC); and a serum sample. Plasma from an alternate source also underwent fractionation and served as an in-house control. Time modulation between 1 and 7 h was observed for the depletion of albumin from these samples. Following albumin depletion, each fraction was trypsin-digested and the peptides were fractionated further using a 2-D LC-MS/MS. Differences in the total number of proteins identified for each sample were also noted.  相似文献   

16.
A rapid and sensitive liquid chromatographic/tandem mass spectrometric method for determination of misoprostol acid, the active metabolite of misoprostol, was developed and validated. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a C(18) column. An API 4000 tandem mass spectrometer equipped with Turbo IonSpray ionization source was used as detector and was operated in the negative ion mode. Multiple reaction monitoring using the precursor to product ion combinations of m/z 367-249 and 296-269 was performed to quantify misoprostol acid and the internal standard hydrochlorothiazide, respectively. The method was linear in the concentration range of 10.0-3000 pg mL(-1) using 200 microL plasma. The lower limit of quantification was 10.0 pg mL(-1). The intra- and inter-day relative standard deviation over the entire concentration range was less than 8.3%. Accuracy determined at three concentrations (25.0, 200 and 2700 pg mL(-1) for misoprostol acid) ranged from -0.5 to 1.2% in terms of relative error. Each plasma sample was chromatographed within 3.5 min. The method was successfully used in a pharmacokinetic study of misoprostol in human plasma after an oral administration of 0.6 mg misoprostol.  相似文献   

17.
The determination of residues of benzimidazole using liquid chromatography and tandem mass spectrometry (LC–MS–MS) with ion spray ionization is described. Swine muscle tissue was spiked with a mixture of fifteen benzimidazoles, including metabolites of fenbendazole and albendazole. As clean-up procedure, an ethyl acetate extraction followed by solid-phase extraction on styrol-divinyl-benzene cartridge was used. The evaluation was performed by selecting the characteristic product ions for the benzimidazoles and using multiple reaction mode. 2-n-Butylmercaptobenzimidazole was used as internal standard. Blank muscle samples were fortified in the concentration range of 1–22 μg/kg. The limits of detection were below 6 μg/kg and the limits of quantification for most benzimidazoles were below 10 μg/kg. The matrix effect was checked using spiked muscle tissues of cattle and sheep as well as liver of cattle. Practical application will be shown by incurred egg material from laying hens treated with flubendazole. The recovery of the clean-up was mostly above 50% in muscle tissue and 70% in egg yolk.  相似文献   

18.
A rapid, sensitive and specific method to quantify carvedilol in human plasma using metoprolol as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using a diethyl-ether solvent. After removed and dried the organic phase, the extracts were reconstituted with a fixed volume of acetonitrile-water (50/50; v/v). The extracts were analyzed by a high performance liquid chromatography coupled to electrospray tandem mass spectrometry (HPLC-MS/MS). Chromatography was performed isocratically on Alltech Prevail C18 5 microm analytical column, (150 mm x 4.6 mm i.d.). The method had a chromatographic run time of 3.5 min and a linear calibration curve over the range 0.1-200 ng ml(-1) (r2>0.997992). The limit of quantification was 0.1 ng ml(-1). This HPLC-MS/MS procedure was used to assess the bioequivalence of two carvedilol 25 mg tablet formulations (carvedilol test formulation from Laboratórios Biosintética Ltda and Coreg from Roche Químicos e Farmacêuticos S.A standard reference formulation). A single 25 mg dose of each formulation was administered to healthy volunteers. The study was conducted using an open, randomized, two-period crossover design with a 2-week wash-out interval. Since the 90% CI for C(max) and AUCs ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration Agency, it was concluded that carvedilol formulation elaborated by Laboratórios Biosintética Ltda is bioequivalent to Coreg formulation for both the rate and the extent of absorption.  相似文献   

19.
Carbofuran (CFN), carbosulfan (CSN) and fenobucarb (FBC) are carbamate pesticides that are widely used in gardening and agriculture for the control of insects. Human poisoning due to occupational or self-poisoning exposures is also reported, so assays are required to quantify the plasma concentration of these insecticides. An LC-MS/MS method was developed and validated for the simultaneous quantification of these three carbamate insecticides in the plasma of patients with acute intentional self-poisoning. Plasma samples were pretreated by acetonitrile for protein precipitation. Chromatography was carried out on a Luna C18(2) analytical column with gradient elution using a mobile phase containing acetonitrile and water with 10mM ammonium acetate. Mass spectrometric analysis was performed by an Applied Biosystems MDS Sciex API 2000 triple quadrupole mass spectrometer coupled with electrospray ionization (ESI) source in the positive ion mode. The total run time was 7 min. The assay was validated over a concentration range from 10 to 1000 ng/ml for CSN and FBC and 20-2000 ng/ml for CFN. The precision and accuracy for both intra- and inter-day determination of all analytes were acceptable (<15%). No significant matrix effect was observed. Stability of compounds was established for short term bench and autosampler storage as well as freeze/thaw cycles. The method was effectively applied to 270 clinical samples from patients with a history of acute intentional carbamate self-poisoning.  相似文献   

20.
We developed and validated a quantitative method for simultaneously determining the concentrations of tracheloside and trachelogenin in rat plasma. Plasma samples were prepared by liquid-liquid extraction with ethyl acetate. Isocratic chromatographic separation was performed on a reversed-phase Diamonsil C(18) column (4.6×200 mm, 5 μm). The mobile phase consisted of methanol and 10mM aqueous ammonium formate (80:20, v/v). Analyte detection was achieved by positive electrospray ionization (ESI) tandem mass spectrometry. Calibration was performed by internal standardization with glipizide, and regression curves ranging from 0.625 to 625 ng/mL were constructed for both the analytes. The intra- and inter-day precision values were below 8%, and accuracy ranged from -5.33% to 2.53% in all quality control samples. In this study, the validated method was successfully applied to determine the pharmacokinetic profile of tracheloside and trachelogenin in rat plasma after oral and intravenous administration of trachelospermi total lignans.  相似文献   