首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We described the development and full validation of rapid and accurate liquid chromatography method, coupled with tandem mass spectrometry detection, for quantification of meprobamate in human plasma with [(13)C-(2)H(3)]-meprobamate as internal standard. Plasma pretreatment involved a one-step protein precipitation with acetonitrile. Separation was performed by reversed-phase chromatography on a Luna MercuryMS C18 (20 mm×4 mm×3 μm) column using a gradient elution mode. The mobile phase was a mix of distilled water containing 0.1% formic acid and acetonitrile containing 0.1% formic acid. The selected reaction monitoring transitions, in electrospray positive ionization, used for quantification were 219.2→158.2 m/z and 223.1→161.1m/z for meprobamate and internal standard, respectively. Qualification transitions were 219.2→97.0 and 223.1→101.1 m/z for meprobamate and internal standard, respectively. The method was linear over the concentration range of 1-300 mg/L. The intra- and inter-day precision values were below 6.4% and accuracy was within 95.3% and 103.6% for all QC levels (5, 75 and 200 mg/L). The lower limit of quantification was 1 mg/L. Total analysis time was reduced to 6 min including sample preparation. The present method is successfully applied to 24/7 clinical toxicology and demonstrated its usefulness to detect meprobamate poisoning.  相似文献   

2.
A method was developed for quantification of oxycodone, noroxycodone, and oxymorphone in small volumes (50 microl) of rat plasma by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry using turbo ion-spray. Deuterated (d3) opioid analogues acted as internal standards. Sample preparation involved protein precipitation with acetonitrile, centrifugal evaporation, and reconstitution in mobile phase; analyte separation was performed on a C18 (5 microm, 2.1 mm x 50 mm) column using a linear gradient program. Lower limits of quantitation (ng/ml) and their between-day accuracy and precision were-oxycodone, 0.9 (-0.2 and 7.8%); noroxycodone, 1.0 (0.6 and 6.2%); oxymorphone 1.0 (-1.8 and 9.5%).  相似文献   

3.
A sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the quantification of miltefosine is presented. A 250 microL human EDTA plasma aliquot was spiked with miltefosine and extracted by a solid-phase extraction method. Separation was performed on a Gemini C18 column (150 mm x 2.0 mm I.D., 5 microm) using an alkaline eluent. Detection was performed by positive ion electrospray ionization followed by triple-quadrupole mass spectrometry. The assay has been validated for miltefosine from 4 to 2000 ng/mL using 250 microL human EDTA plasma samples. Results from the validation demonstrate that miltefosine can be accurately and precisely quantified in human plasma. At the lowest level, the intra-assay precision was lower than 10.7%, the inter-assay precision was 10.6% and accuracies were between 95.1 and 109%. This assay is successfully used in a clinical pharmacokinetic study with miltefosine.  相似文献   

4.
To measure myoglobin, a marker for myocardial infarction, directly in human serum, two-dimensional liquid chromatography in combination with electrospray ionization mass spectrometry was applied as an analytical method. High-abundant serum proteins were depleted by strong anion-exchange chromatography. The myoglobin fraction was digested and injected onto a 60 mm x 0.2 mm i.d. monolithic capillary column for quantitation of selected peptides upon mass spectrometric detection. The addition of known amounts of myoglobin to the serum sample was utilized for calibration, and horse myoglobin was added as an internal standard to improve reproducibility. Calibration graphs were linear and facilitated the reproducible and accurate determination of the myoglobin amount present in serum. Manual data evaluation using integrated peak areas and an automated multistage algorithm fitting two-dimensional models of peptide elution profiles and isotope patterns to the mass spectrometric raw data were compared. When the automated method was applied, a myoglobin concentration of 460 pg/microL serum was determined with a maximum relative deviation from the theoretical value of 10.1% and a maximum relative standard deviation of 13.4%.  相似文献   

5.
A robust and sensitive method using liquid chromatography-tandem mass spectrometry was developed and validated for the simultaneous determination of a novel topoisomerase 1 inhibitor CH0793076 (3076), the prodrug CH4556300 (TP300), and the active metabolite CH0793011 (3011) in human plasma. All plasma analyzed with this method was acidified with 1M HCl and 46% citric acid solution in a ratio of 100:10:1 (v:v:v) to avoid the pH-based degradation of TP300 and to shift the equilibria of 3076 and 3011 between the lactone and carboxylate forms towards the lactone forms. After the plasma proteins were precipitated with methanol:acetonitrile:HCl 1M (50:50:1, v:v:v) containing stable isotopic internal standards, the analytes were trapped on an Xterra MS C18 column (10×2.1 mm i.d., 5 μm) and separated on a Gemini C18 column (50×2.0 mm i.d., 5 μm) using column-switching liquid chromatography. Electrospray ionization in the positive-ion mode and multiple reaction monitoring were used to quantify the analytes with transitions m/z 587.2>441.2 for TP300, 459.1>415.2 for 3076, and 475.1>361.1 for 3011. The inter- and intra-day precisions were below 12%, and the accuracy was between -16% and 16% at the lower limit of quantitation (LLOQ) and between -11% and 14% at the other quality controls. The LLOQs of TP300, 3076, and 3011 were 0.8, 0.04, and 0.04 ng/mL, respectively. The validated method was successfully applied to clinical sample analysis and incurred sample reanalysis was also conducted.  相似文献   

6.
The alkaloids from Piper longum L. showed protective effects on Parkinson's disease models in our previous study and piperine and piperlonguminine were the two main constituents in the alkaloids. The present study aimed at developing a rapid, sensitive, and accurate UFLC-ESI-MS/MS method and validating it for the simultaneous determination of piperine and piperlonguminine in rat plasma using terfenadine as the internal standard. The analytes and internal standard (IS) were extracted from rat plasma using a simple protein precipitation by adding methanol/acetonitrile (1:1, v/v). A Phenomenex Gemini 3 u C18 column (20 mm × 2.00 mm, 3 μm) was used to separate the analytes and IS using a gradient mode system with a mobile phase consisting of water with 0.1% formic acid (mobile phase A) and acetonitrile with 0.1% formic acid (mobile phase B) at a flow rate of 0.4 mL/min and an operating column temperature of 25°C. The total analytical run time was 4 min. The detection was performed using the positive ion electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode with transitions at m/z 286.1-201.1 for piperine, m/z 274.0-201.1 for piperlonguminine, and m/z 472.4-436.4 for the IS. The calibration curves were both linear (r>0.995) over a concentration range of 1.0 to 1000 ng/mL; the lower limit of quantification (LLOQ) was 1.0 ng/mL for both piperine and piperlonguminine. The intra-day and inter-day precisions (RSD %) were <12.1%, accuracies ranged from 86.6 to 120%, and recoveries ranged from 90.4 to 108%. The analytes were proven stable in the short-term, long-term, and after three freeze-thaw cycles. The method was successfully applied to pharmacokinetic studies of piperine and piperlonguminine in rats after oral administration of alkaloids from P. longum L.  相似文献   

7.
To support toxicokinetic assessments, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of BMS-790052 in rat, dog, monkey, rabbit and mouse K(2)EDTA plasma. The drug was isolated from buffered samples using ISOLUTE C8 96-well solid phase extraction (SPE) plates. Chromatographic separation was achieved on a Waters Atlantis dC18 analytical column (2.1 mm × 50 mm, 5 μm) with detection accomplished using an API 4000 tandem mass spectrometer in positive ion electrospray and multiple reaction monitoring (MRM) mode. The standard curves, which ranged from 5.00 to 2000 ng/mL for BMS-790052, were fitted to a 1/x(2) weighted linear regression model. The intra-assay precision (%CV) and inter-assay precision (%CV) were within 8.5%, and the assay accuracy (%Dev) was within ±7.1 for rat, dog, monkey, rabbit and mouse K(2)EDTA plasma. This accurate, precise, and selective SPE/LC-MS/MS method has been successfully applied to analyze several thousands of non-clinical study samples.  相似文献   

8.
A simple, highly selective, sensitive and reproducible liquid chromatography-electrospray ionization mass spectrometry method has been developed for the direct and simultaneous determination of reduced (GSH) and oxidized (GSSG) glutathione in microdialysis samples from human dermis. Chromatographic separation was carried out on an MODULO CART QS KROMASIL 5C18 (250 mm × 2 mm × 5 μm) analytical column at a flow rate of 0.25 ml/min. An isocratic mode was used and consisted of acidified water and acetonitrile (50/50, v/v). To improve the sensitivity, silver nitrate was added as post-column reagent. A trap mass spectrum was used equipped with an ESI interface. The limits of detection and quantification were respectively 0.12 and 0.4 ng/ml for GSH and 0.2 and 0.5 ng/ml for GSSG. Intra-day and inter-day accuracy and precision were determined and the variability was less than 6.2% (R.S.D.).  相似文献   

9.
A rapid, sensitive and selective high-performance liquid chromatography-tandem mass spectrometric method (HPLC-MS) was developed and validated to determine the 14-(3-methylbenzyl)matrine (3MBM) and 14-(4-methylbenzyl)matrine (4MBM) levels in rat plasma in the present study. The analytes were separated using a C18 column (1.9 μm, 2.1 mm × 100 mm) equipped with a Security Guard C18 column (5 μm, 2.1 mm × 10 mm), followed by detection via triple-quadrupole mass spectrometry using an electrospray ionization (ESI) source. Sample pretreatment involved one-step protein precipitation with isopropanol:ethyl acetate (v/v, 25:75), and pseudoephedrine hydrochloride was used as an internal standard. The method was linear in the concentration range of 5–2000 ng/ml for both compounds. The intra-day and inter-day relative standard deviations (RSDs) were less than 15%, and all relative errors (REs) were within 15%. The proposed method enables the unambiguous identification and quantification of these two compounds in vivo. This study is the first to determine the 3MBM and 4MBM levels in rat plasma after oral administration of these compounds. These results provide a meaningful basis for evaluating the clinical applications of these medicines.  相似文献   

10.
A rapid and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed and validated for quantification of cyclizine and its main metabolite norcyclizine in human plasma. Samples were prepared by protein precipitation with acetonitrile and cinnarizine was used as internal standard (recovery >87%). The analytes were eluted from a C8 50 mm×2.0 mm analytical column using a linear gradient of methanol and 0.05% formic acid with a total analysis time of 4 min. Analytes were detected by MS/MS using electrospray ionisation in the positive mode with multiple reactions monitoring (MRM) of the precursor ion/product ion transitions 267.2/167.2 for cyclizine and 253.2/167.2 for norcyclizine. Matrix effects were negligible. Standard curves for cyclizine and norcyclizine were linear (r(2)≥0.996) over the range 2-200 ng/mL, with 2 ng/mL representing the lower limit of quantification. Relative standard deviations were <14% for intra- and inter-day precision and the accuracy was within ±8%. The assay was successfully applied to a clinical study.  相似文献   

11.
A sensitive and rapid method was developed and validated for the quantitative analysis of the novel anticancer agent SZ-685C in rat plasma using high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) in negative ion mode in order to support the following pre-clinical and clinical studies. SZ-685C and the internal standard (IS, emodin) were extracted from rat plasma by a simple liquid-liquid extraction technique using ethyl acetate as extraction solvent. Chromatographic separation was performed on an Elite Hypersil BDS C18 column (100 mm × 2.1 mm i.d., 3 μm). Elution was carried out using methanol/acetonitrile/2mM ammonium formate (pH 4) (80:15:5 (v/v/v)) at a flow-rate of 0.3 mL/min with a run time of 2.5 min. This assay was linear over a concentration range of 50-10,000 ng/mL with a lower limit of quantification of 50 ng/mL. The intra- and inter-batch precision was less than 15% for all quality control samples at concentrations of 100, 1000 and 7500 ng/mL. These results indicate that the method was efficient with a short run time and acceptable accuracy, precision and sensitivity. This method was successfully applied to explore pharmacokinetics of SZ-685C in rats after oral and intravenous administration of this agent. The absolute bioavailability is about 54.8-66.8% and the t(1/2) is 5.7-9.2h, these results provide basic information for further comprehensive pre-clinical research.  相似文献   

12.
A sensitive, specific and fast high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) assay for the determination of vinorelbine in mouse and human plasma is presented. A 200 microL aliquot was extracted with solid-phase extraction (SPE) using Bond-Elut C(2) cartridges. Dried extracts were reconstituted in 100 microL 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) containing the internal standard vintriptol (100 ng/mL) and 10 microL volumes were injected onto the HPLC system. Separation was achieved on a 50 mm x 2.0 mm i.d. Gemini C(18) column using isocratic elution with 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) at a flow rate of 0.4 mL/min. HPLC run time was only 5 min. Detection was performed using positive ion electrospray ionization followed by tandem mass spectrometry (ESI-MS/MS). The assay quantifies vinorelbine from 0.1 to 100 ng/mL using human plasma sample volumes of 200 microL. With this method vinorelbine can be measured in mouse plasma samples when these samples are diluted eight times in control human plasma. Calibration samples prepared in control human plasma can be used for the quantification of the drug. The lower limit of quantification in mouse plasma is 0.8 ng/mL. This assay is used to support preclinical and clinical pharmacologic studies with vinorelbine.  相似文献   

13.
A rapid and sensitive method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of codeine, ephedrine, guaiphenesin and chlorpheniramine in beagle dog plasma has been developed and validated. Following liquid-liquid extraction, the analytes were separated on a reversed-phase C(18) column (150 mm × 2.0 mm, 3 μm) using formic acid:10 mM ammonium acetate:methanol (0.2:62:38, v/v/v) as mobile phase at a flow rate of 0.2 mL/min and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode. The method was linear for all analytes over the following concentration (ng/mL) ranges: codeine 0.08-16; ephedrine 0.8-160; guaiphenesin 80-16,000; chlorpheniramine 0.2-40. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. It is the first time that the validated HPLC-MS/MS method was successfully applied to a bioequivalence study in 6 healthy beagle dogs.  相似文献   

14.
A novel isocratic reversed-phase high performance liquid-chromatography/ultraviolet detection method for simultaneous determination of cefdinir and cefixime in human plasma was developed and validated after optimization of various chromatographic conditions and other experimental parameters. Sample preparation based on a simple extraction procedure consisting of deproteination and extraction with 3 parts of 6% trichloroacetic acid aqueous solution followed by volume make up with the aqueous component of the mobile phase obtained best recoveries of the two analytes. Samples were separated on a Supelco Discovery HS C(18) (150 mm × 4.6 mm, 5 μm) analytical column protected by a Perkin Elmer C(18) (30 mm × 4.6 mm, 10 μm) guard cartridge. The mobile phase, methanol/acetonitrile (50/50, v/v):0.05% trifluoroacetic acid (19:81, v/v), operated at 50°C column oven temperature was pumped at a flow rate of 2.0 mL min(-1) and the column eluents were monitored at a wavelength of 285 nm. When Sample was injected into the Perkin Elmer high performance liquid-chromatography system through Rheodyne manual (or auto-sampler) injector equipped with 20 μL loop, separation was achieved within 4 min. The present method demonstrated acceptable values for selectivity, linearity within the expected concentration range (0.004-5.0 μg mL(-1); r(2)>0.999 for both analytes), recovery (>95% for cefdinir and >96% for cefixime), precision (%RSD<2.0 for cefdinir and <2.2 for cefixime), sensitivity (limit of detection: 1 ng mL(-1) and lower limit of quantification: 4 ng mL(-1) for both analytes), stability of solutions, and robustness. The method was efficiently applied to a pharmacokinetic study in healthy volunteers.  相似文献   

15.
A novel, rapid and specific liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the simultaneous quantification of gefitinib and its predominant metabolite, O-desmethyl gefitinib in human plasma. Chromatographic separation of analytes was achieved on an Alltima C18 analytical HPLC column (150 mm × 2.1 mm, 5 μm) using an isocratic elution mode with a mobile phase comprised acetonitrile and 0.1% formic acid in water (30:70, v/v). The flow rate was 300 μL/min. The chromatographic run time was 3 min. The column effluents were detected by API 4000 triple quadrupole mass spectrometer using electrospray ionization (ESI) in positive mode. Linearity was demonstrated in the range of 5-1000 ng/mL for gefitinib and 5-500 ng/mL for O-desmethyl gefitinib. The intra- and inter-day precisions for gefitinib and O-desmethyl gefitinib were ≤10.8% and the accuracies ranged from 89.7 to 104.7% for gefitinib and 100.4 to 106.0% for O-desmethyl gefitinib. This method was used as a bioanalytical tool in a phase I clinical trial to investigate the possible effect of hydroxychloroquine on the pharmacokinetics of gefitinib. The results of this study enabled clinicians to ascertain the safety of the combination therapy of hydroxychloroquine and gefitinib in patients with advanced (Stage IIIB-IV) non-small cell lung cancer (NSCLC).  相似文献   

16.
A method for the quantification of two peptide HIV-1 fusion inhibitors (enfuvirtide, T-20 and tifuvirtide, T-1249) and one metabolite of enfuvirtide (M-20) in human plasma has been developed and validated, using liquid chromatography coupled with electrospray tandem mass spectrometry (LC-MS/MS). The analytes were extracted from plasma by solid-phase extraction (SPE) on vinyl-copolymer cartridges. Chromatographic separation of the peptides was performed on a Symmetry 300 C(18) column (50mmx2.1mm I.D., particle size 3.5 microm), using a water-acetonitrile gradient containing 0.25% (v/v) formic acid. The triple quadrupole mass spectrometer was operated in the positive ion-mode and multiple reaction monitoring (MRM) was used for peak detection. Deuterated (d60) enfuvirtide and (d50) tifuvirtide were used as internal standards. The assay was linear over a concentration range of 20-10,000 ng/ml for enfuvirtide and tifuvirtide and of 20-2000 ng/ml for M-20. Intra- and inter-assay precisions and deviations from the nominal concentrations were 相似文献   

17.
Fractionation prior to mass spectrometry is an indispensable step in proteomics. In this paper we report the success of performing offline reversed phase high pressure liquid chromatography (HPLC) fractionation on a C18 2.0 mm×150 mm column at the peptide level with microliter per minute flow rates prior to online nano-flow reversed phase liquid chromatography mass spectrometry (nanoLC-MS) using the well-studied fungus Saccharomyces cerevisiae. A C18 75 μm×150 mm column was used online and the online elution gradients for each fraction were adjusted in order to obtain well resolved separation. Comparing this method directly to only performing nanoLC-MS we observed a 61.6% increase in the number of identified proteins. At a 1% false discovery rate 1028 proteins were identified using two dimensions of RPLC versus 636 proteins identified in a single nano-flow separation. The majority of proteins identified by one dimension of nano-LC were present in the proteins identified in our two dimensional strategy. Although increasing analysis time, this non-orthogonal and facile pre-fractionation method affords a more comprehensive examination of the proteome.  相似文献   

18.
19.
Protein identification plays an important role in today's academic and industrial proteomic research. Commonly used methods for the separation of proteins from complex samples include liquid chromatography (e.g., ion exchange, reversed-phase, hydrophobic interaction), or types of gel electrophoresis (e.g., 1d and 2d PAGE). Relevant proteins separated in the latter way are often cut out, cleaved with trypsin "in gel," and the resulting peptide mixtures combined with matrix and spotted onto a target plate for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF-ms) analysis. Subsequently, proteins can be identified by comparison of the resulting peptide mass fingerprints against different databases.(1) since the success of protein identification can be enhanced by the desalting and concentration of the samples, an innovative C18-membrane was incorporated into a microspin column (Vivapure C18 micro spin column, Vivascience AG, Hannover, Germany) to analyze its performance for sample preparation prior to MALDI-ToF-ms. Rapid concentration of single or multiple 200-microl volumes through an available membrane only 2 mm in diameter allowed for analysis of very dilute samples. We observed the successful and rapid desalting of urea-containing protein samples at 100 fmol/mul up to a mass of approximately 70 KDA and the concentration of digest peptides from a solution of 1 fmol/microl using C18-membrane technology.  相似文献   

20.
A sensitive and rapid LC-MS/MS method was developed and validated for the determination of levamisole in human plasma. The assay was based on liquid-liquid extraction of analytes from human plasma with ethyl ether. Chromatographic separation was carried on an Agilent HC-C(8) column (150 mm × 4.6 mm, 5 μm) at 40°C, with a mobile phase consisting of acetonitrile-10 mM ammonium acetate (70:30, v/v), a flow rate of 0.5 mL/min and a total run time of 6 min. Detection and quantification were performed by mass spectrometry in the multiple reaction monitoring mode with positive electrospray ionization m/z at 205.1→178.2 for levamisole, and m/z 296.1→264.1 for mebendazole (internal standard). The assay was linear over a concentration range of 0.1-30 ng/mL with a lower limit of quantification of 0.1 ng/mL. The coefficient of variation of the assay precision was less than 8.5%. The assay was successfully used to analyze human plasma samples in a pharmacokinetic study where levamisole was administered as a liniment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号