首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
染色质免疫沉淀技术在研究DNA与蛋白质相互作用中的应用   总被引:1,自引:0,他引:1  
王春雨  石建党  朱彦  张琚 《遗传》2005,27(5):801-807
在后基因组时代,DNA-蛋白质的相互作用是研究基因表达调控的一个重要领域。与其他方法相比,染色质免疫沉淀技术(chromatin immunoprecipitation assay, ChIP)是一种在体内研究DNA-蛋白质相互作用的理想的方法。近年来这种方法与DNA芯片和分子克隆技术相结合,可用于高通量的筛选已知蛋白因子的未知DNA靶点和研究反式作用因子在整个基因组上的分布情况,这将有助于深入理解DNA-蛋白质相互作用的调控网络。总结了染色质免疫沉淀技术的方法,特别介绍了使用这些方法取得的最新进展。  相似文献   

2.
The "quantitative" ChIP, a tool commonly used to study protein-DNA interactions in cells and tissue, is a difficult assay often plagued with technical error. We present, herein, the process required to merge multiple protocols into a quick, reliable and easy method and an approach to accurately quantify ChIP DNA prior to performing PCR. We demonstrate that high intensity sonication for at least 30 min is required for full cellular disruption and maximum DNA recovery because ChIP lysis buffers fail to lyse formaldehyde-fixed cells. In addition, extracting ChIP DNA with chelex-100 yields samples that are too dilute for evaluation of shearing efficiency or quantification via nanospectrophotometry. However, DNA extracted from the Mock-ChIP supernatant via the phenol-chloroform-isoamyl alcohol (PCIA) method can be used to evaluate DNA shearing efficiency and used as the standard in a fluorescence-based microplate assay. This enabled accurate quantification of DNA in chelex-extracted ChIP samples and normalization to total DNA concentration prior to performing real-time PCR (rtPCR). Thus, a quick ChIP assay that can be completed in nine bench hours over two days has been validated along with a rapid, accurate and repeatable way to quantify ChIP DNA. The resulting rtPCR data more accurately depicts treatment effects on protein-DNA interactions of interest.  相似文献   

3.
Reverse ChIP:研究DNA-蛋白质相互作用的新方法   总被引:1,自引:0,他引:1  
反向染色质免疫共沉淀技术(reverse chromatin immunoprecipitation assay,Reverse ChIP)是一种在体内状态下分析DNA-蛋白质相互作用的新方法.它用特异的核酸探针捕获靶DNA片段及与其相结合的蛋白质,蛋白质用质谱仪检测,以达到确定靶DNA位点全部相关蛋白质的目的.其可对靶DNA位点相关蛋白质进行全面、系统地鉴定,特别是寻找已知DNA元件相应的调节蛋白.在发现、鉴定靶DNA位点相关蛋白质和研究DNA-蛋白质相互作用中有重要应用价值.  相似文献   

4.
5.
Adli M  Bernstein BE 《Nature protocols》2011,6(10):1656-1668
Chromatin immunoprecipitation (ChIP) combined with high-throughput sequencing (ChIP-seq) has become the gold standard for whole-genome mapping of protein-DNA interactions. However, conventional ChIP protocols necessitate the use of large numbers of cells, and library preparation steps associated with current high-throughput sequencing platforms require substantial amounts of DNA; both of these factors preclude the application of ChIP-seq technology to many biologically important but rare cell types. Here we describe a nano-ChIP-seq protocol that combines a high-sensitivity small-scale ChIP assay and a tailored procedure for generating high-throughput sequencing libraries from scarce amounts of ChIP DNA. In terms of the numbers of cells required, the method provides two to three orders of magnitude of improvement over the conventional ChIP-seq method and the entire procedure can be completed within 4 d.  相似文献   

6.
7.
8.
Fast chromatin immunoprecipitation assay   总被引:6,自引:1,他引:5  
Chromatin immunoprecipitation (ChIP) is a widely used method to explore in vivo interactions between proteins and DNA. The ChIP assay takes several days to complete, involves several tube transfers and uses either phenol–chlorophorm or spin columns to purify DNA. The traditional ChIP method becomes a challenge when handling multiple samples. We have developed an efficient and rapid Chelex resin-based ChIP procedure that dramatically reduces time of the assay and uses only a single tube to isolate PCR-ready DNA. This method greatly facilitates the probing of chromatin changes over many time points with several antibodies in one experiment.  相似文献   

9.
10.
11.
人 Elp3(human elongator protein 3, hElp3)具有组蛋白乙酰转移酶活性,是与延伸中的 RNA 聚合酶Ⅱ结合的 elongator 复合物的催化亚基,可参与组蛋白的乙酰化修饰与基因的转录延伸. Elp3 及其复合物功能异常与人类多种疾病相关. 为运用染色质免疫沉淀等手段深入研究 Elp3 功能,PCR 法克隆 pYES2-hElp3 质粒中编码 hElp3的N端亲水区段(1~69 氨基酸残基),构建原核表达载体 pMXB10-hElp3-210,经 IPTG 诱导和几丁质柱纯化后,免疫兔制备多克隆抗体. ELISA 检测显示,该抗体有较高的效价(不低于1∶2 500).免疫印迹实验结果表明,该抗体可与纯化的及 HeLa 细胞中的 hElp3 蛋白特异性结合.运用该抗体对转入 elp3Δ菌株的人 Elp3 的染色质免疫沉淀实验结果表明,人 Elp3 可参与酵母 SSA3 基因的转录调控,这可能是人Elp3 能够部分补偿酵母 SSA3 基因延迟表达缺陷的原因.  相似文献   

12.
An on-line assay for a thermostable pullulanase and antithrombin III (AT III) is described. The assay is based on the formation of aggregates between the protein to be measured and antibodies raised against this protein. Assay automation was achieved by utilizing the flow injection analysis (FIA) principles. The apparatus, a stopped-flow, merging-zone manifold, is described in detail. Since the reaction used in an FIA system does not have to reach equilibrium, it was possible to reduce the time for an assay cycle to 2.5 min. A method for simulating cultivation conditions was developed for assay optimization. Using this method, a detection limit of I mg l−1 together with a standard deviation of 1.5 was found. A sandwich ELISA was used as reference assay in the case of AT III and an enzymatic activity assay in the case of pullulanase. Correlation coefficients of 0.988 (AT III) and 0.976 (pullulanase) were determined. The turbidimetric assay was successfully used for pullulanase monitoring during a 240-h cultivation of Clostridium thermosulfurogenes.  相似文献   

13.
The standard Bradford protein assay is insensitive to collagen. But if a small, sub-threshold amount of SDS is added to the sample, the response to collagen in increased by at least an order of magnitude, while, on average, the sensitivity for non-collagens is decreased by approximately a factor of 2. As a result comparable color formation is achieved with both collagens and non-collagens. The addition of protein to a sub-threshold amount of SDS results in the formation of a green color measurable as an increase in absorbance at 700 nm, in contrast to the blue color measured at 595 nm in the standard assay. Depending upon the source, the threshold level for SDS varies from 30 to 50 μg. The response to protein is linear up to approximately 40 μg of protein per ml of reagent.  相似文献   

14.
Chromatin state of a 2-Mb region harboring Rit1/Bcl11b on mouse chromosome 12 was examined using two distinct methods. One is ChIP assay examining the degree of enrichment with histone H3 methylated at lysine 9 (H3-mLys9) in chromatin and the other is H/E (heterochromatin/euchromatin) assay that measures a chromatin condensation state by using centrifugation. The ChIP assay showed that a 50-kb interval covering the gene and an upstream region constituted chromatin enriched with unmethylated H3-mLys9 in cells expressing Rit1 compared to cells not expressing Rit1. In contrast, regions other than the 50-kb interval did not show much difference in the enrichment between the two different types of cells. On the other hand, H/E assay of two expressing and two non-expressing tissues provided compatible fractionation patterns, suggesting that the chromatin condensation state detected by H/E assay is correlated with the chromatin state controlled by histone H3 tail modification linked to gene expression. These results indicate that the centrifugation-based H/E assay should provide a new approach to the regulation of chromatin structure with respect to its condensation state, complementing ChIP assays.  相似文献   

15.
The Current State of Chromatin Immunoprecipitation   总被引:2,自引:0,他引:2  
  相似文献   

16.
17.
18.
Chromatin immunoprecipitation (ChIP) is an important technique in the study of DNA/protein interactions. The ChIP procedure, however, has limitations in that it is lengthy, can be inconsistent, and is prone to nonspecific binding of DNA and proteins to the bead-based solid-phase matrices that are often used for the immunoprecipitation step. In this investigation, we examined the utility of a new matrix for ChIP assays, BioVyon Protein A, a solid support based on porous polyethylene. In ChIP experiments carried out using two antibodies and seven DNA loci, the performance of BioVyon Protein A was significantly better, with a greater percentage of DNA pull-down in all of the assays tested compared with bead-based matrices, Protein A Sepharose, and Dynabeads Protein A. Furthermore, the rigid porous disc format within a column made the BioVyon matrix much easier to use with fewer steps and less equipment requirements, resulting in a significant reduction in the time taken to process the ChIP samples. In summary, BioVyon Protein A provides a column-based assay method for ChIP and other immunoprecipitation-based procedures; the rigid porous structure of BioVyon enables a fast and robust protocol with higher ChIP enrichment ratios.  相似文献   

19.
20.
Protocol for the fast chromatin immunoprecipitation (ChIP) method   总被引:1,自引:0,他引:1  
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号