1.

Background

In-stent restenosis (ISR) remains a common life-threatening complication and some studies have shown that pioglitazone can reduce the incidence of ISR in patients with drug-eluting stents (DES) implantation. We conducted a meta-analysis to assess the effect of pioglitazone in preventing ISR after DES implantation.

Methods

Randomized controlled trials (RCTs) investigating the effects of pioglitazone for ISR after DES implantation were identified by systematic searches of multiple online databases and manual searches of related reference lists of identified trials through May 2014. The primary endpoint was the rate of ISR. Secondary endpoints included minimum lumen diameter, percentage stenosis of stented vessels, late loss, in-stent neointimal volume, target vessel revascularization (TVR), target lesion revascularization, myocardial infarction, stent thrombosis and death.

Results

Five studies, comprising 255 pioglitazone-treated patients and 245 controls, were identified in the current meta-analysis. Pioglitazone did not significantly reduce the rate of ISR (P = 0.20) with low heterogeneity (I2 = 13.3%, P = 0.32). For the secondary outcomes, pioglitazone did not substantially affect the pooled estimates of these endpoints except late loss (P = 0.01) and TVR (P = 0.04).

Conclusions

The limited evidence indicates that pioglitazone does not demonstrate markedly beneficial effect in patients subjected to coronary DES implantation. However, the results should be interpreted with care given the small sample size. Further large-scale RCTs are needed.  相似文献   

2.

Objective

In recent years, cerebral artery stenting has become an effective method for the treatment of cerebral artery stenosis. However, methods for assessing efficacy and techniques for follow-up imaging still need to be developed. This study was designed to evaluate the application of transcranial color-coded sonography (TCCS) in assessing stenting of middle cerebral artery (MCA) stenosis. And, two new imaging techniques (vascular enhancement technology (VET) and 3-dimensional (3D) imaging) were tried out and evaluated.

Method

We enrolled 43 patients with cerebral artery stenosis for vascular stent implantation. All patients were examined by ultrasonography and confirmed through digital subtraction angiography. The stenosis was imaged and blood flow parameters were analyzed before and after the procedure using TCCS. VET and 3D imaging model were used in part of the patients. Important postoperative hemodynamic changes were noted.

Results

1) Adequate stent image was present in 41 out of 43 patients as detected by postoperative 2-dimensional imaging. Images lacking clarity were obtained in 2 patients. 2) The perioperative and postoperative (one week follow-up) instantaneous blood flow velocity at the site of stenosis was significantly decreased (P<0.05) when compared with preoperative levels. Differences between postoperative (one week follow-up) and preoperative blood flow velocity were significant (P<0.05). Differences in blood flow velocity at long-term follow-up (six months and two years) compared to one-week values were not statistically significant (P>0.05). 3) VET imaging visualizes the MCA lumen and stent morphology clearly. 3D ultrasound can be used for imaging of the stent shape as well as its inner surface.

Conclusion

TCCD can be considered a quick and effective clinical detection method to evaluate the intracranial arterial hemodynamics changes before and after stenting treatment for MCA stenosis. New imaging technologies 3D and VET can achieve additional image information.  相似文献   

3.

Background  

In-stent restenosis rates have been closely linked to the wall shear stress distribution within a stented arterial segment, which in turn is a function of stent design. Unfortunately, evaluation of hemodynamic performance can only be evaluated with long term clinical trials. In this work we introduce a set of metrics, based on statistical moments, that can be used to evaluate the hemodynamic performance of a stent in a standardized way. They are presented in the context of a 2D flow study, which analyzes the impact of different strut profiles on the wall shear stress distribution for stented coronary arteries.  相似文献   

4.

Objectives

To evaluate stent-related adverse cardiac events and bleeding complications within 30 days after surgical procedures in patients with recent drug-eluting stent (DES) implantation, in whom a bridging protocol was used.

Methods

In our centre a bridging protocol is used in patients scheduled for cardiac or non-cardiac surgery within 6 months after PCI with DES implantation. Clopidogrel and in some cases also acetylsalicylic acid is discontinued 5 days prior to the planned intervention and patients are admitted 2 to 3 days before the intervention for tirofiban infusion. This is discontinued 4 h before intervention. Close postoperative monitoring is performed and double antiplatelet therapy is restarted as soon as possible. Thirty-six consecutive patients were included in the protocol, 15 receiving coronary artery bypass graft and 21 non-cardiac interventions. Thrombotic and bleeding complications were studied for up to 30 days after the bridged procedure.

Results

No incidences of stent thrombosis or other adverse cardiac events (mortality, myocardial infarction) were seen in up to 30 days of follow-up. However, 6 bleeding events were reported of which 5 required a blood transfusion.

Conclusion

Our bridging protocol in patients requiring surgery after recent PCI with DES seems adequate to prevent stent thrombosis in this high-risk group. The bleeding risk is not insignificant but in our patient group controllable without major late sequelae. Larger studies should be performed to establish safety and efficacy in order to develop guidelines for these patients.  相似文献   

5.

Background

Saphenous vein grafts develop an aggressive atherosclerotic process and the efficacy of drug eluting stents (DES) in treating saphenous vein graft (SVG) lesions has not been convincingly demonstrated. The aim of this study was to review and analyze the current literature for controlled studies comparing DES versus bare metal stents (BMS) for treatment of SVG stenoses.

Methodology/Principal Findings

We searched several scientific databases and conference proceedings up to March 15, 2010 for controlled studies comparing target vessel revascularization (TVR) between DES and BMS. Summary odds ratios (OR) for the primary endpoint TVR and secondary endpoints infarction, stent thrombosis and death were calculated using random-effect models. A total of 29 studies (3 randomized controlled trials RCT) involving 7549 (202 in RCT) patients were included. The need for target vessel revascularization in the DES group tended to be lower compared to BMS for the 3 RCT (OR 0.50 [0.24–1.00]; p = 0.051) and for observational studies (0.62 [0.49–0.79]; p<0.001). There was no significant difference in the risk for myocardial infarction in the RCT (OR 1.25 [0.22–6.99]; p = 0.250) but a lower risk for DES based on the observational studies 0.68 [0.49–0.95]; p = 0.023. The risk for stent thrombosis was found to be non-different in the RCT (OR 0.78 [0.03–21.73], p = 0.885) while it was in favor of DES in the observational studies (0.58 [0.38 – 0.84]; p<0.001). The mortality was not significantly different between DES and BMS in the RCT''s (OR 2.22 [0.17 – 29.50]; p = 0.546) while the observation studies showed a decreased mortality in the DES group (0.69 [0.55–0.85]; p<0.001).

Conclusion

DES may decrease TVR rate in treatment of SVG stenoses. No differences in reinfarction rate, stent thrombosis or mortality was found between the DES and BMS groups in the RCT''s while the observational data showed lower risk for myocardial infarction, stent thrombosis and death in the DES group. This may be a result of patient selection bias in the observational studies or represent a true finding that was not the detected in the RCT analysis due to limited statistical power.  相似文献   

6.

Background

Cadmium (Cd) is a nonessential heavy metal, causing oxidative damage to various tissues and associated with hypertension. Tetrahydrocurcumin (THU), a major metabolite of curcumin, has been demonstrated to be an antioxidant, anti-diabetic, anti-hypertensive and anti-inflammatory agent. In this study, we investigated the protective effect of THU against Cd-induced hypertension, raised arterial stiffness and vascular remodeling in mice.

Methods

Male ICR mice received CdCl2 (100 mg/l) via drinking water for 8 weeks. THU was administered intragastrically at dose of 50 or 100 mg/kg/day concurrently with Cd treatment.

Results

Administration of CdCl2 significantly increased arterial blood pressure, blunted vascular responses to vasoactive agents, increased aortic stiffness, and induced hypertrophic aortic wall remodeling by increasing number of smooth muscle cells and collagen deposition, decreasing elastin, and increasing matrix metalloproteinase (MMP)-2 and MMP-9 levels in the aortic medial wall. Supplementation with THU significantly decreased blood pressure, improved vascular responsiveness, and reversed the structural and mechanical alterations of the aortas, including collagen and elastin deposition. The reduction on the adverse response of Cd treatment was associated with upregulated eNOS and downregulated iNOS protein expressions, increased nitrate/nitrite level, alleviated oxidative stress and enhanced antioxidant glutathione. Moreover, THU also reduced the accumulation of Cd in the blood and tissues.

Conclusions

Our results suggest that THU ameliorates cadmium-induced hypertension, vascular dysfunction, and arterial stiffness in mice through enhancing NO bioavailability, attenuating oxidative stress, improving vascular remodeling and decreasing Cd accumulation in other tissues. THU has a beneficial effect in moderating the vascular alterations associated with Cd exposure.  相似文献   

7.

Background

Pulmonary arterial hypertension is characterized by increased thickness of pulmonary vessel walls due to both increased proliferation of pulmonary arterial smooth muscle cell (PASMC) and deposition of extracellular matrix. In patients suffering from pulmonary arterial hypertension, endothelin-1 (ET-1) synthesis is up-regulated and may increase PASMC activity and vessel wall remodeling through transforming growth factor beta-1 (TGF-β1) and connective tissue growth factor.

Objective

To assess the signaling pathway leading to ET-1 induced proliferation and extracellular matrix deposition by human PASMC.

Methods

PASMC were serum starved for 24 hours before stimulation with either ET-1 and/or TGF-β1. ET-1 was inhibited by Bosentan, ERK1/2 mitogen activated protein kinase (MAPK) was inhibited by U0126 and p38 MAPK was inhibited by SB203580.

Results

ET-1 increased PASMC proliferation when combined with serum. This effect involved the mitogen activated protein kinases (MAPK) ERK1/2 MAPK and was abrogated by Bosentan which caused a G1- arrest through activation of p27(Kip). Regarding the contribution of extracellular matrix deposition in vessel wall remodeling, TGF-β1 increased the deposition of collagen type-I and fibronectin, which was further increased when ET-1 was added mainly through ERK1/2 MAPK. In contrast, collagen type-IV was not affected by ET-1. Bosentan dose-dependently reduced the stimulatory effect of ET-1 on collagen type-I and fibronectin, but had no effect on TGF-β1.

Conclusion and Clinical Relevance

ET-1 alone does not induce PASMC proliferation and extracellular matrix deposition. However, ET-1 significantly up-regulates serum induced proliferation and TGF-β1 induced extracellular matrix deposition, specifically of collagen type-I and fibronectin. The synergistic effects of ET-1 on serum and TGF-β1 involve ERK1/2 MAPK and may thus present a novel mode of action in the pathogenesis of pulmonary arterial hypertension.  相似文献   

8.

Introduction

Two self-expandable stents, the Neuroform and the Enterprise stent, are widely used for stent-assisted coiling (SAC) of complex shaped intracranial aneurysms. However, comparative knowledge about technical feasibility, peri- and post-procedural morbidity and mortality, packing densities as well as follow-up data is limited.

Material and Methods

We conducted a retrospective study to investigate differences in aneurysms stented with the Enterprise or Neuroform stents. Angiographic follow-up (mean 19.42 months) was available in 72.6% (61/84) of aneurysms treated with stent-assisted coiling. We further sought to compare stent-assisted coiling to a matched patient population with aneurysms treated by conventional coil embolization.

Results

The stenting success rate of the Enterprise was higher compared to the Neuroform stent (46/48 and 42/51, respectively). In 5 of 9 cases in which the Neuroform stent was not navigable to the landing zone, we successfully deployed an Enterprise stent instead. Eventually, 42 aneurysms were coiled after stenting in each group. We observed no significant differences in peri-procedural complication rate, post-procedural hospital stay, packing density, recurrence rate or number of in-stent stenosis. Strikingly, 36.1% of followed aneurysms in the SAC group showed progressive occlusion on angiographic follow-up imaging. The packing density was significantly higher in aneurysms treated by SAC as compared to conventionally coiled aneurysms, while recanalization rate was significantly lower in the SAC group.

Conclusion

The procedural success rate is higher using the Enterprise, but otherwise both stents exhibited similar characteristics. Lower recurrence frequency and complication rates comparable to conventional coil embolization emphasize the importance of stent-assisted coiling in the treatment of complex aneurysms. Progressive occlusion on angiographic follow-up was a distinct and frequent observation in the SAC group and may in part be due to flow diversion.  相似文献   

9.

Background

Failure of bioprosthetics is usually caused by calcification of the leaflets as a consequence of high tensile stresses. The stentless valve resembles native mitral valve anatomy, has a flexible leaflet attachment and a suspension at the papillary muscles, and preserves annuloventricular continuity. In this study, the effects of the stentless valve design on leaflet stress were investigated with a finite element model.

Methods

Finite element models of the stentless quadrileaflet mitral valve were created in the close and open configurations. The geometry of the stented trileaflet mitral valve was also analyzed for comparative purposes. Under the designated pressures, the regional stresses were evaluated, and the distributions of stresses were assessed.

Results

Regardless of whether the valve is in the open or close configuration, the maximum first principal stress was significantly lower in the stentless valve than in the stented valve. For the stentless valves, limited stress concentration was discretely distributed in the papillary flaps under both close and open conditions. In contrast, in the stented valve, increased stress concentration was evident at the central belly under the open condition and at the commissural attachment under close condition. In either configuration, the maximum second principal stress was markedly lower in the stentless valve than in the stented valve.

Conclusions

The stentless valve was associated with a significant reduction in leaflet stress and a more homogeneous stress distribution compared to the stented valve. These findings are consistent with recent reports of the clinical effectiveness of the stentless quadrileaflet mitral valve.  相似文献   

10.

Background

The widespread use of coronary stents has exposed a growing population to the risk of stent thrombosis, but the importance in terms of risk of ST-segment elevation myocardial infarctions (STEMIs) remains unclear.

Methods

We studied five years follow-up data for 2,098 all-comer patients treated with coronary stents in the randomized SORT OUT II trial (mean age 63.6 yrs. 74.8% men). Patients who following stent implantation were readmitted with STEMI were included and each patient was categorized ranging from definite- to ruled-out stent thrombosis according to the Academic Research Consortium definitions. Multivariate logistic regression was performed on selected covariates to assess odds ratios (ORs) for definite stent thrombosis.

Results

85 patients (4.1%), mean age 62.7 years, 77.1% men, were admitted with a total of 96 STEMIs, of whom 60 (62.5%) had definite stent thrombosis. Notably, definite stent thrombosis was more frequent in female than male STEMI patients (81.8% vs. 56.8%, p = 0.09), and in very late STEMIs (p = 0.06). Female sex (OR 3.53 [1.01–12.59]) and clopidogrel (OR 4.43 [1.03–19.01]) was associated with increased for definite stent thrombosis, whereas age, time since stent implantation, use of statins, initial PCI urgency (STEMI [primary PCI], NSTEMI/unstable angina [subacute PCI] or stable angina [elective PCI]), and glucose-lowering agents did not seem to influence risk of stent thrombosis.

Conclusion

In a contemporary cohort of coronary stented patients, stent thrombosis was evident in more than 60% of subsequent STEMIs.  相似文献   

11.

Background

Stent length serves as a predictor of restenosis in use of bare metal stents (BMS). This has been demonstrated in a feasibility study that used a single short BMS implant (<9 mm) in a high proportion of lesions; the study observed a low rate of restenosis.

Methods

We performed a pilot prospective study to investigate in a series of consecutive patients the immediate and long-term effects of implantation of either 1) a single short BMS for all lesions with low probability of restenosis or 2) a drug-eluting stent (DES) for all other lesions.

Results

The 200 patients studied had 236 coronary artery lesions that were treated with short BMS in 168/236 patients (71.2%) and with DES in 68/236 patients (28.8%). Angiographic success was achieved in 230/236 lesions (97.5%) and procedural success in 194/200 patients (97.0%). Restenosis occurred in 15/153 lesions (9.8%) after short BMS, in 3/62 lesions (4.8%) after DES, and in 18/215 of all lesions (8.4%) angiographically controlled after six to eight months. Target vessel revascularization was performed in 16/218 lesion (7.4%).

Conclusion

Most of the coronary artery lesions in this small group of consecutive patients were treated sufficiently with a single BMS implant. This differential approach of treating suitable lesions in medium- to large-sized vessels with a single short BMS device and treating all other lesions with a DES implant resulted in a low incidence of restenosis.  相似文献   

12.
13.

Background

Recent clinical studies have shown that recanalization rates are lower in stent-assisted coil embolization than in coiling alone in the treatment of cerebral aneurysms.

Objective

This study aimed to assess and compare the hemodynamic effect of stent struts and straightening of vessels by stent placement on reducing flow velocity in sidewall aneurysms, with the goal of reducing recanalization rates.

Methods

We evaluated 16 sidewall aneurysms treated with Enterprise stents. We performed computational fluid dynamics simulations using patient-specific geometries before and after treatment, with or without stent struts.

Results

Stent placement straightened vessels by a mean (±standard deviation) of 12.9°±13.1° 6 months after treatment. Placement of stent struts in the initial vessel geometries reduced flow velocity in aneurysms by 23.1%±6.3%. Straightening of vessels without stent struts reduced flow velocity by 9.6%±12.6%. Stent struts had significantly stronger effects on reducing flow velocity than straightening (P = 0.004, Wilcoxon test). Deviation of the effects was larger by straightening than by stent struts (P = 0.01, F-test). The combination of stent struts and straightening reduced flow velocity by 32.6%±12.2%. There was a trend that larger inflow angles produced a larger reduction in flow velocity by straightening of vessels (P = 0.16).

Conclusion

In sidewall aneurysms, stent struts have stronger effects (approximately 2 times) on reduction in flow velocity than straightening of vessels. Hemodynamic effects by straightening vary in each case and can be predicted by inflow angles of pre-operative vessel geometry. These results may be useful to design a treatment strategy for reducing recanalization rates.  相似文献   

14.

Background

Evidence suggests a role of both innate and adaptive immunity in the development of pulmonary arterial hypertension. The complement system is a key sentry of the innate immune system and bridges innate and adaptive immunity. To date there are no studies addressing a role for the complement system in pulmonary arterial hypertension.

Methodology/Principal Findings

Immunofluorescent staining revealed significant C3d deposition in lung sections from IPAH patients and C57Bl6/J wild-type mice exposed to three weeks of chronic hypoxia to induce pulmonary hypertension. Right ventricular systolic pressure and right ventricular hypertrophy were increased in hypoxic vs. normoxic wild-type mice, which were attenuated in C3−/− hypoxic mice. Likewise, pulmonary vascular remodeling was attenuated in the C3−/− mice compared to wild-type mice as determined by the number of muscularized peripheral arterioles and morphometric analysis of vessel wall thickness. The loss of C3 attenuated the increase in interleukin-6 and intracellular adhesion molecule-1 expression in response to chronic hypoxia, but not endothelin-1 levels. In wild-type mice, but not C3−/− mice, chronic hypoxia led to platelet activation as assessed by bleeding time, and flow cytometry of platelets to determine cell surface P-selectin expression. In addition, tissue factor expression and fibrin deposition were increased in the lungs of WT mice in response to chronic hypoxia. These pro-thrombotic effects of hypoxia were abrogated in C3−/− mice.

Conclusions

Herein, we provide compelling genetic evidence that the complement system plays a pathophysiologic role in the development of PAH in mice, promoting pulmonary vascular remodeling and a pro-thrombotic phenotype. In addition we demonstrate C3d deposition in IPAH patients suggesting that complement activation plays a role in the development of PAH in humans.  相似文献   

15.

Background

Intimal injury rapidly activates TGFβ and enhances vascular repair by the growth of endothelial (EC) and vascular smooth muscle cells (VSMC). The response to the TGFβ family of growth factors can be modified by BAMBI (BMP, Activin, Membrane Bound Inhibitor) acting as a non-signaling, competitive antagonist of TGFβ type I receptors such as ALK 1 and 5. In vivo the effect of BAMBI will depend on its cell-specific expression and of that of the ALK type receptors. We recently reported EC restricted BAMBI expression and genetic elimination of BAMBI resulting in an in vitro and in vivo phenotype characterized by endothelial activation and proliferation involving alternative pathway activation by TGFβ through ALK 1.

Methodology/Principal Findings

To test the hypothesis that BAMBI modulates arterial response to injury via its effects on endothelial repair and arterial wall neovascularization we used a model of femoral arterial denudation injury in wild type (WT) and BAMBI−/− mice. Arterial response was evaluated at 2 and 4 weeks after luminal endothelial denudation of femoral arteries. The BAMBI−/− genotype mice showed accelerated luminal endothelial repair at 2 weeks and a highly unusual increase in arterial wall neovascularization compared to WT mice. The exuberant intimal and medial neovessel formation with BAMBI−/− genotype was also associated with significant red blood cell extravasation. The bleeding into the neointima at 2 weeks transiently increased it’s area in the BAMBI−/−genotype despite the faster luminal endothelial repair in this group. Vascular smooth muscle cells were decreased at 2 weeks in BAMBI−/− mice, but comparable to wild type at 4 weeks.

Conclusions/Significance

The absence of BAMBI results in a highly unusual surge in arterial wall neovascularization that surprisingly mimiks features of intra-plaque hemorrhage of advanced atheroma in a mechanical injury model. This suggests important effects of BAMBI on arterial EC homeostasis that need to be further studied in a model of inflammatory atherosclerosis.  相似文献   

16.

Background

The changes of hemodynamics and drug concentration distribution caused by the implantation of drug eluting stents (DESs) in curved vessels have significant effects on In-Stent Restenosis.

Methods

A 3D virtual stent with 90°curvature was modelled and the distribution of wall shear stress (WSS) and drug concentration in this model were numerically studied at Reynolds numbers of 200, 400, 600, 800.

Results

The results showed that (1) the intensity of secondary flow at the 45° cross-section was stronger than that at the 90° cross-section; (2) As the Reynolds number increases, the WSS decreases. When the Reynolds number reaches 600, the low-WSS region only accounts for 3% of the total area. (3) The effects of Reynolds number on drug concentration in the vascular wall decreases in proportionally and then the blood velocity increased 4 times, the drug concentration in the vascular wall decreased by about 30%. (4) The size of the high drug concentration region is inversely proportional to the Reynolds number. As the blood velocity increases, the drug concentration in the DES decreases, especially at the outer bend.

Conclusions

It is beneficial for the patient to decrease vigorous activities and keep calm at the beginning of the stent implantation, because a substantial amount of the drug is released in the first two months of stent implantation, thus a calm status is conducive to drug release and absorption; Subsequently, appropriate exercise which increases the blood velocity is helpful in decreasing regions of low-WSS.
  相似文献   

17.
Drug-eluting stents (DES), which release anti-proliferative drugs into the arterial wall in a controlled manner, have drastically reduced the rate of in-stent restenosis and revolutionized the treatment of atherosclerosis. However, late stent thrombosis remains a safety concern in DES, mainly due to delayed healing of the endothelial wound inflicted during DES implantation. We present a framework to optimize DES design such that restenosis is inhibited without affecting the endothelial healing process. To this end, we have developed a computational model of fluid flow and drug transport in stented arteries and have used this model to establish a metric for quantifying DES performance. The model takes into account the multi-layered structure of the arterial wall and incorporates a reversible binding model to describe drug interaction with the cells of the arterial wall. The model is coupled to a novel optimization algorithm that allows identification of optimal DES designs. We show that optimizing the period of drug release from DES and the initial drug concentration within the coating has a drastic effect on DES performance. Paclitaxel-eluting stents perform optimally by releasing their drug either very rapidly (within a few hours) or very slowly (over periods of several months up to one year) at concentrations considerably lower than current DES. In contrast, sirolimus-eluting stents perform optimally only when drug release is slow. The results offer explanations for recent trends in the development of DES and demonstrate the potential for large improvements in DES design relative to the current state of commercial devices.  相似文献   

18.

Background

Long lesions have been associated with adverse outcomes in percutaneous coronary interventions with bare metal stents (BMS). However, the exact impact of lesion length on the short- and long-term outcomes of drug-eluting stent (DES) implantations is not as clear.

Methods and Results

This study compared the impact of lesion length on angiographic and clinical outcomes of BMS and DES in a single-center prospective registry. Lesion length was divided into tertiles. The primary endpoints were angiographically defined binary in-stent restenosis (ISR) rate and major adverse cardiac event (MACE). Of the 4,312 de novo lesions in 3,447 consecutive patients in the CAPTAIN registry, 2,791 lesions (of 2,246 patients) received BMS, and the remaining 1,521 lesions (of 1,201 patients) received DES. The mean follow-up duration was 4.5 years. The longer the lesion, the higher the ISR rate (14%, 18%, and 29%, p<0.001) and the lower the MACE-free survivals (p = 0.007) in the BMS group. However, lesion length showed no such correlation with ISR rates (4.7%, 3.3%, and 7.8%, p = 0.67) or MACE-free survivals (p = 0.19) in the DES group.

Conclusions

In our single-center prospective registry, lesion length defined in tertiles has no impact on the short-term (ISR) or long-term (MACE) outcomes of patients implanted with DES. In contrast, longer lesion correlates with higher ISR and MACE rates in BMS group.  相似文献   

19.

Background

Cilostazol(CLZ) has been used as a vasodilating anti-platelet drug clinically and demonstrated to inhibit proliferation of smooth muscle cells and effect on endothelial cells. However, the effect of CLZ on re-endothelialization including bone marrow (BM)-derived endothelial progenitor cell (EPC) contribution is unclear. We have investigated the hypothesis that CLZ might accelerate re-endothelialization with EPCs.

Methodology/Principal Findings

Balloon carotid denudation was performed in male Sprague-Dawley rats. CLZ group was given CLZ mixed feed from 2weeks before carotid injury. Control group was fed normal diet. CLZ accelerated re-endothelialization at 2 weeks after surgery and resulted in a significant reduction of neointima formation 4 weeks after surgery compared with that in control group. CLZ also increased the number of circulating EPCs throughout the time course. We examined the contribution of BM-derived EPCs to re-endothelialization by BM transplantation from Tie2/lacZ mice to nude rats. The number of Tie2-regulated X-gal positive cells on injured arterial luminal surface was increased at 2 weeks after surgery in CLZ group compared with that in control group. In vitro, CLZ enhanced proliferation, adhesion and migration activity, and differentiation with mRNA upregulation of adhesion molecule integrin αvβ3, chemokine receptor CXCR4 and growth factor VEGF assessed by real-time RT-PCR in rat BM-derived cultured EPCs. In addition, CLZ markedly increased the expression of SDF-1α that is a ligand of CXCR4 receptor in EPCs, in the media following vascular injury.

Conclusions/Significance

CLZ promotes EPC mobilization from BM and EPC recruitment to sites of arterial injury, and thereby inhibited neointima formation with acceleration of re-endothelialization with EPCs as well as pre-existing endothelial cells in a rat carotid balloon injury model. CLZ could be not only an anti-platelet agent but also a promising tool for endothelial regeneration, which is a key event for preventing atherosclerosis or restenosis after vascular intervention.  相似文献   

20.

Background and Methods

It is important to ensure that blood flow is modelled accurately in numerical studies of arteries featuring drug-eluting stents due to the significant proportion of drug transport from the stent into the arterial wall which is flow-mediated. Modelling blood is complicated, however, by variations in blood rheological behaviour between individuals, blood’s complex near-wall behaviour, and the large number of rheological models which have been proposed. In this study, a series of steady-state computational fluid dynamics analyses were performed in which the traditional Newtonian model was compared against a range of non-Newtonian models. The impact of these rheological models was elucidated through comparisons of haemodynamic flow details and drug transport behaviour at various blood flow rates.

Results

Recirculation lengths were found to reduce by as much as 24% with the inclusion of a non-Newtonian rheological model. Another model possessing the viscosity and density of blood plasma was also implemented to account for near-wall red blood cell losses and yielded recirculation length increases of up to 59%. However, the deviation from the average drug concentration in the tissue obtained with the Newtonian model was observed to be less than 5% in all cases except one. Despite the small sensitivity to the effects of viscosity variations, the spatial distribution of drug matter in the tissue was found to be significantly affected by rheological model selection.

Conclusions/Significance

These results may be used to guide blood rheological model selection in future numerical studies. The clinical significance of these results is that they convey that the magnitude of drug uptake in stent-based drug delivery is relatively insensitive to individual variations in blood rheology. Furthermore, the finding that flow separation regions formed downstream of the stent struts diminish drug uptake may be of interest to device designers.  相似文献   