首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 968 毫秒
1.
Aims: Vibrio identification by means of traditional microbiological methods is time consuming because of the many biochemical tests that have to be performed to distinguish closely related species. This work aimed at evaluating the use of MALDI‐TOF mass spectrometry for the rapid identification of Vibrio (V.) spp. as an advantageous application to rapidly discriminate the most important Vibrio spp. and distinguish Vibrio spp. from closely related bacterial species like Photobacterium damselae and Grimontia hollisae and other aquatic bacteria like Aeromonas spp. Methods and Results: Starting from sub‐colony amounts of pure cultures grown on agar plates, a very simple sample preparation procedure was established and combined with a rapid and automated measurement protocol that allowed species identification within minutes. Closely related species like Vibrio alginolyticus and Vibrio parahaemolyticus or Vibrio cholerae and Vibrio mimicus could thus be differentiated by defining signatures of species‐identifying biomarker ions (SIBIs). As a reference method for species designation and for determination of relationships between strains with molecular markers, partial rpoB gene sequencing was applied. Conclusions: The MALDI‐TOF MS‐based method as well as the rpoB sequence‐based approach for Vibrio identification described in this study produced comparable classification results. The construction of phylogenetic trees from MALDI‐TOF MS and rpoB sequences revealed a very good congruence of both methods. Significance and Impact of the Study: Our results suggest that whole‐cell MALDI‐TOF MS‐based proteometric characterization represents a powerful tool for rapid and accurate classification and identification of Vibrio spp. and related species.  相似文献   

2.
Sandflies (Diptera: Psychodidae) (Newstead, 1911) are blood‐feeding insects that transmit human pathogens including Leishmania (Trypanosomatida: Trypanosomatidae) parasites, causative agents of the leishmaniases. To elucidate Leishmania transmission cycles, conclusive identification of vector species is essential. Molecular approaches including matrix‐assisted laser desorption ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) protein profiling have recently emerged to complement morphological identification. The aim of this study was to evaluate the effect of the trap type used to collect sandflies, specifically Centers for Disease Control (CDC) light or sticky traps, the two most commonly used in sandfly surveys, on subsequent MALDI‐TOF MS protein profiling. Specimens of five species (Phlebotomus ariasi, Phlebotomus papatasi, Phlebotomus perniciosus, Phlebotomus sergenti, Sergentomyia minuta) collected in periurban and agricultural habitats in southeast Spain were subjected to protein profiling. Acquired protein spectra were queried against an in‐house reference database and their quality assessed to evaluate the trap type effect. The results indicate that trap choice can substantially affect the quality of protein spectra in collected sandflies. Whereas specimens retrieved from light traps produced intense and reproducible spectra that allowed reliable species determination, profiles of specimens from sticky traps were compromised and often did not enable correct identification. Sticky traps should therefore not be used in surveys that deploy MALDI‐TOF MS protein profiling for species identification.  相似文献   

3.
Identification of differentially proteomic responses to external pHs would pave an access for understanding of survival mechanisms of bacteria living at extreme pH environment. We cultured Alkalimonas amylolytica N10 (N10), a novel alkaliphilic bacterium found in Lake Chahannor, in media with three different pHs and extracted the correspondent membrane and cytoplasm proteins for proteomic analysis through 2‐DE. The differential 2‐DE spots corresponding to the altered pHs were delivered to MALDI TOF/TOF MS for protein identification. Since the genomic data of strain N10 was unavailable, we encountered a problem at low rate of protein identification with 18.1%. We employed, therefore, a combined strategy of de novo sequencing to analyze MS/MS signals generated from MALDI TOF/TOF MS. A significantly improved rate of protein identification was thus achieved at over than 70.0%. Furthermore, we extensively investigated the expression of these pH‐dependent N10 genes using Western blot and real‐time PCR. The conclusions drawn from immunoblot and mRNA measurements were mostly in agreement with the proteomic observations. We conducted the bioinformatic analysis to all the pH‐dependent N10 proteins and found that some membrane proteins participated in iron transport were differentially expressed as external pH elevated and most of differential proteins with increased or bell‐shape mode of pH‐dependence were involved in bioenergetic process and metabolism of carbohydrates, fatty acid, amino acids, and nucleotides. Our data thus provide a functional profile of the pH‐responsive proteins in alkaliphiles, leading to elucidation of alkaliphilic‐adaptive mechanism.  相似文献   

4.
Emerging methods based on mass spectrometry (MS) can be used in the rapid identification of microorganisms. Thus far, these practical and rapidly evolving methods have mainly been applied to characterize prokaryotes. We applied matrix‐assisted laser‐desorption‐ionization‐time‐of‐flight mass spectrometry MALDI‐TOF MS in the analysis of whole cells of 18 N. fowleri isolates belonging to three genotypes. Fourteen originated from the cerebrospinal fluid or brain tissue of primary amoebic meningoencephalitis patients and four originated from water samples of hot springs, rivers, lakes or municipal water supplies. Whole Naegleria trophozoites grown in axenic cultures were washed and mixed with MALDI matrix. Mass spectra were acquired with a 4700 TOF‐TOF instrument. MALDI‐TOF MS yielded consistent patterns for all isolates examined. Using a combination of novel data processing methods for visual peak comparison, statistical analysis and proteomics database searching we were able to detect several biomarkers that can differentiate all species and isolates studied, along with common biomarkers for all N. fowleri isolates. Naegleria fowleri could be easily separated from other species within the genus Naegleria. A number of peaks detected were tentatively identified. MALDI‐TOF MS fingerprinting is a rapid, reproducible, high‐throughput alternative method for identifying Naegleria isolates. This method has potential for studying eukaryotic agents.  相似文献   

5.
Calanoid copepods play an important role in the pelagic ecosystem making them subject to various taxonomic and ecological studies, as well as indicators for detecting changes in the marine habitat. For all these investigations, valid identification, mainly of sibling and cryptic species as well as early life history stages, represents a central issue. In this study, we compare species identification methods for pelagic calanoid copepod species from the North Sea and adjacent regions in a total of 333 specimens. Morphologically identified specimens were analysed on the basis of nucleotide sequences (i.e. partial mitochondrial cytochrome c oxidase subunit I (COI) and complete 18S rDNA) and on proteome fingerprints using the technology of matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS). On all three molecular approaches, all specimens were classified to species level indicated by low intraspecific and high interspecific variability. Sequence divergences in both markers revealed a second Pseudocalanus species for the southern North Sea identified as Pseudocalanus moultoni by COI sequence comparisons to GenBank. Proteome fingerprints were valid for species clusters irrespective of high intraspecific variability, including significant differences between early developmental stages and adults. There was no effect of sampling region or time; thus, trophic effect, when analysing the whole organisms, was observed in species‐specific protein mass spectra, underlining the power of this tool in the application on metazoan species identification. Because of less sample preparation steps, we recommend proteomic fingerprinting using the MALDI‐TOF MS as an alternative or supplementary approach for rapid, cost‐effective species identification.  相似文献   

6.
The discovery of novel biomarkers by means of advanced detection tools based on proteomic analysis technologies necessitates the development of improved diagnostic methods for application in clinical routine. On the basis of three different application examples, this review presents the limitations of conventional routine diagnostic assays and illustrates the advantages of immunoaffinity enrichment combined with MALDI‐TOF MS. Applying this approach increases the specificity of the analysis supporting a better diagnostic recognition, sensitivity, and differentiation of certain diseases. The use of MALDI‐TOF MS as detection method facilitates the identification of modified peptides and proteins providing additional information. Further, employing respective internal standard peptides allows for relative and absolute quantitation which is mandatory in the clinical context. Although MALDI‐TOF MS is not yet established for clinical routine diagnostics this technology has a high potential for improvement of clinical diagnostics and monitoring therapeutic efficacy.  相似文献   

7.
Aims: To propose a universal workflow of sample preparation method for the identification of highly pathogenic bacteria by MALDI‐TOF MS. Methods and Results: Fifteen bacterial species, including highly virulent Gram‐positive (Bacillus anthracis and Clostridium botulinum) and Gram‐negative bacteria (Brucella melitensis, Burkholderia mallei, Francisella tularensis, Shigella dysenteriae, Vibrio cholerae, Yersinia pestis and Legionella pneumophila), were employed in the comparative study of four sample preparation methods compatible with MALDI‐TOF MS. The yield of bacterial proteins was determined by spectrophotometry, and the quality of the mass spectra, recorded in linear mode in the range of 2000–20 000 Da, was evaluated with respect to the information content (number of signals) and quality (S/N ratio). Conclusions: Based on the values of protein concentration and spectral quality, the method using combination of ethanol treatment followed by extraction with formic acid and acetonitrile was the most efficient sample preparation method for the identification of highly pathogenic bacteria using MALDI‐TOF MS. Significance and Impact of the Study: The method using ethanol/formic acid generally shows the highest extraction efficacy and the spectral quality with no detrimental effect caused by storage. Thus, this can be considered as a universal sample preparation method for the identification of highly virulent micro‐organisms by MALDI‐TOF mass spectrometry.  相似文献   

8.
Flea identification is a significant issue because some species are considered as important vectors of several human pathogens that have emerged or re‐emerged recently, such as Bartonella henselae (Rhizobiales: Bartonellaceae) and Rickettsia felis (Rickettsiales: Rickettsiaceae). Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) has been evaluated in recent years for the identification of multicellular organisms, including arthropods. A preliminary study corroborated the usefulness of this technique for the rapid identification of fleas, creating a preliminary database containing the spectra of five species of flea. However, longterm flea preservation in ethanol did not appear to be an adequate method of storage in the context of specimen identification by MALDI‐TOF MS profiling. The goal of the present work was to assess the performance of MALDI‐TOF MS in the identification of seven flea species [Ctenocephalides felis (Siphonaptera: Pulicidae), Ctenocephalides canis, Pulex irritans (Siphonaptera: Pulicidae), Archaeopsylla erinacei (Siphonaptera: Pulicidae), Leptopsylla taschenbergi (Siphonaptera: Ceratophyllidae), Stenoponia tripectinata (Siphonaptera: Stenoponiidae) and Nosopsyllus fasciatus (Siphonaptera: Ceratophyllidae)] collected in the field and stored in ethanol for different periods of time. The results confirmed that MALDI‐TOF MS can be used for the identification of wild fleas stored in ethanol. Furthermore, this technique was able to discriminate not only different flea genera, but also the two congeneric species C. felis and C. canis.  相似文献   

9.
Arthropod‐borne diseases are important causes of morbidity and mortality. The identification of vector species relies mainly on morphological features and/or molecular biology tools. The first method requires specific technical skills and may result in misidentifications, and the second method is time‐consuming and expensive. The aim of the present study is to assess the usefulness and accuracy of matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) as a supplementary tool with which to identify mosquito vector species and to invest in the creation of an international database. A total of 89 specimens belonging to 10 mosquito species were selected for the extraction of proteins from legs and for the establishment of a reference database. A blind test with 123 mosquitoes was performed to validate the MS method. Results showed that: (a) the spectra obtained in the study with a given species differed from the spectra of the same species collected in another country, which highlights the need for an international database; (b) MALDI‐TOF MS is an accurate method for the rapid identification of mosquito species that are referenced in a database; (c) MALDI‐TOF MS allows the separation of groups or complex species, and (d) laboratory specimens undergo a loss of proteins compared with those isolated in the field. In conclusion, MALDI‐TOF MS is a useful supplementary tool for mosquito identification and can help inform vector control.  相似文献   

10.
11.
12.
Introduction – A variety of sample preparation protocols for plant proteomic analysis using two‐dimensional gel electrophoresis (2‐DE) have been reported. However, they usually have to be adapted and further optimised for the analysis of plant species not previously studied. Objective – This work aimed to evaluate different sample preparation protocols for analysing Carica papaya L. leaf proteins through 2‐DE. Methodology – Four sample preparation methods were tested: (1) phenol extraction and methanol–ammonium acetate precipitation; (2) no precipitation fractionation; and the traditional trichloroacetic acid–acetone precipitation either (3) with or (4) without protein fractionation. The samples were analysed for their compatibility with SDS–PAGE (1‐DE) and 2‐DE. Fifteen selected protein spots were trypsinised and analysed by matrix‐assisted laser desorption/ionisation time‐of‐flight tandem mass spectrometry (MALDI‐TOF‐MS/MS), followed by a protein search using the NCBInr database to accurately identify all proteins. Results – Methods number 3 and 4 resulted in large quantities of protein with good 1‐DE separation and were chosen for 2‐DE analysis. However, only the TCA method without fractionation (no. 4) proved to be useful. Spot number and resolution advances were achieved, which included having an additional solubilisation step in the conventional TCA method. Moreover, most of the theoretical and experimental protein molecular weight and pI data had similar values, suggesting good focusing and, most importantly, limited protein degradation. Conclusion – The described sample preparation method allows the proteomic analysis of papaya leaves by 2‐DE and mass spectrometry (MALDI‐TOF‐MS/MS). The methods presented can be a starting point for the optimisation of sample preparation protocols for other plant species. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
The quality of MALDI‐TOF mass spectrometric analysis is highly dependent on the matrix and its deposition strategy. Although different matrix‐deposition methods have specific advantages, one major problem in the field of proteomics, particularly with respect to quantitation, is reproducibility between users or laboratories. Compounding this is the varying crystal homogeneity of matrices depending on the deposition strategy used. Here, we describe a novel optimised matrix‐deposition strategy for LC‐MALDI‐TOF/TOF MS using an automated instrument that produces a nebulised matrix “mist” under controlled atmospheric conditions. Comparisons of this with previously reported strategies showed the method to be advantageous for the atypical matrix, 2,5‐DHB, and improved phosphopeptide ionisation when compared with deposition strategies for CHCA. This optimised DHB matrix‐deposition strategy with LC‐MALDI‐TOF/TOF MS, termed EZYprep LC, was subsequently optimised for phosphoproteome analysis and compared to LC‐ESI‐IT‐MS and a previously reported approach for phosphotyrosine identification and characterisation. These methods were used to map phosphorylation on epidermal growth factor‐stimulated epidermal growth factor receptor to gauge the sensitivity of the proposed method. EZYprep DHB LC‐MALDI‐TOF/TOF MS was able to identify more phosphopeptides and characterise more phosphorylation sites than the other two proteomic strategies, thus proving to be a sensitive approach for phosphoproteome analysis.  相似文献   

14.
The proteome of Tropheryma whipplei, the intracellular bacterium responsible for Whipple's disease (WD), was analyzed using two complementary approaches: 2‐DE coupled with MALDI‐TOF and SDS‐PAGE with nanoLC‐MS/MS. This strategy led to the identification of 206 proteins of 808 predicted ORFs, resolving some questions raised by the genomic sequence of this bacterium. We successfully identified antibiotic targets and proteins with predicted N‐terminal signal sequences. Additionally, we identified a family of surface proteins (known as T. whipplei surface proteins (WiSPs)), which are encoded by a unique group of species‐specific genes and serve as both coding regions and DNA repeats that promote genomic recombination. Comparison of the protein expression profiles of the intracellular facultative host‐associated WD bacterium with other host‐associated, intracellular obligate, and environmental bacteria revealed that T. whipplei shares a proteomic expression profile with other host‐associated facultative intracellular bacteria. In summary, this study describes the global protein expression pattern of T. whipplei and reveals some specific features of the T. whipplei proteome.  相似文献   

15.
Here, we report evaluation of five oligoprobes designed from intergenic spacer (IGS) region sequences for identification of cyathostomin species. Oligoprobes were designed for identification of Cylicocyclus ashworthi, Cylicocyclus nassatus, Cylicostephanus longibursatus, Cylicostephanus goldi and a fifth probe designed to identify all members of this tribe. PCR amplification of IGS DNA from 16 cyathostomin species allowed sequence comparison and identification of four putative species-specific probes. Southern blotting of amplified products from 16 species showed that all probes were species-specific. The fifth probe recognised all 16 cyathostomin species but did not bind to members of the genus Strongylus. Furthermore, these probes were used to identify individual infective L3, eggs and L4 indicating that they will be invaluable to furthering the study of the epidemiology and pathogenesis of these important equine nematodes.  相似文献   

16.
Oliver Bader 《Proteomics》2013,13(5):788-799
MALDI‐TOF MS‐based species identification has found its place in many clinical routine diagnostic laboratories over the past years. Several well‐established commercial systems exist and these allow precise analyses not only among bacteria, but also among clinically important yeasts. This methodology shows higher precision than biochemical and microscopic methods at significantly reduced turnaround times. Furthermore, the differentiation of different filamentous fungi including most dermatophytes and zygomycetes has been established. The direct identification of yeasts from blood culture bottles will be possible in a routine fashion with new standardized procedures. In addition to species identification, the MALDI‐TOF MS technology offers several further possibilities, like assays to detect or predict resistance phenotypes in fungi as well as subtyping approaches to detect clinically relevant subgroups. The differences between the commercial systems are discussed with respect to fungi and an overview of their performances provided. Factors influencing outcome of MALDI‐TOF‐based species identification are discussed.  相似文献   

17.
Ticks and fleas are vectors for numerous human and animal pathogens. Controlling them, which is important in combating such diseases, requires accurate identification, to distinguish between vector and non‐vector species. Recently, matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF‐MS) was applied to the rapid identification of arthropods. The growth of this promising tool, however, requires guidelines to be established. To this end, standardization protocols were applied to species of Rhipicephalus sanguineus (Ixodida: Ixodidae) Latreille and Ctenocephalides felis felis (Siphonaptera: Pulicidae) Bouché, including the automation of sample homogenization using two homogenizer devices, and varied sample preservation modes for a period of 1–6 months. The MS spectra were then compared with those obtained from manual pestle grinding, the standard homogenization method. Both automated methods generated intense, reproducible MS spectra from fresh specimens. Frozen storage methods appeared to represent the best preservation mode, for up to 6 months, while storage in ethanol is also possible, with some caveats for tick specimens. Carnoy's buffer, however, was shown to be less compatible with MS analysis for the purpose of identifying ticks or fleas. These standard protocols for MALDI‐TOF MS arthropod identification should be complemented by additional MS spectrum quality controls, to generalize their use in monitoring arthropods of medical interest.  相似文献   

18.
The MALDI‐TOF MS has already been a main platform for phosphoproteome analysis. However, there are some weaknesses in direct analysis of endogenous phosphopeptides by MALDI‐TOF MS because of the serious suppression effect and poor ionization efficiency, which is brought by the excess of nonphosphopeptides and protein. It is essential to enrich endogenous phosphopeptides from complex biosamples efficiently prior to MALDI‐TOF MS analysis. Herein, we present a time‐saving and detailed protocol for the synthesis of titanium(iv)‐immobilized magnetic mesoporous silica nanoparticles (denoted as Fe3O4@mSiO2‐Ti4+), the subsequent enrichment process, and MALDI‐TOF MS analysis. We tested the LOD, size‐exclusive effect, reproducibility, and stability of Fe3O4@mSiO2‐Ti4+ nanoparticles. Furthermore, the ability of this protocol for identifying endogenous phosphopeptides in healthy human serum and saliva was investigated.  相似文献   

19.
The minimal antibiotic options for carbapenemase‐producing Gram‐negative bacteria necessitate their rapid detection. A literature review of a variety of phenotypic and genotypic methods is presented. Advances in culture methods and screening media are still subject to long incubation hours. Biochemical methods have shorter turnaround times and higher sensitivities and specificities, but cannot differentiate between various types and variants. Spectrophotometric methods are cheap and efficient, but are uncommon in many clinical settings, while the MALDI‐TOF MS is promising for species identification, typing and resistance gene determination. Although next generation sequencing (NGS) technologies provide a better platform to detect, type and characterize carbapenem‐resistant bacteria, the different NGS platforms, the large computer memories and space needed to process and store genomic data and the nonuniformity in data analysis platforms are still a challenge. The sensitivities, specificities and turnaround times recorded in the various studies reviewed favours the use of the biochemical tests (Carba NP or Rapid Carb screen tests) for the detection of putative carbapenemase‐producing isolates. MALDI‐TOF MS and/or molecular methods like microarray, loop‐mediated isothermal amplification and real‐time multiplex PCR assays could be used for further characterization in a reference laboratory. NGS may be used for advanced epidemiological and molecular studies.  相似文献   

20.
Mass spectrometric profiling approaches such as MALDI‐TOF and SELDI‐TOF are increasingly being used in disease marker discovery, particularly in the lower molecular weight proteome. However, little consideration has been given to the issue of sample size in experimental design. The aim of this study was to develop a protocol for the use of sample size calculations in proteomic profiling studies using MS. These sample size calculations can be based on a simple linear mixed model which allows the inclusion of estimates of biological and technical variation inherent in the experiment. The use of a pilot experiment to estimate these components of variance is investigated and is shown to work well when compared with larger studies. Examination of data from a number of studies using different sample types and different chromatographic surfaces shows the need for sample‐ and preparation‐specific sample size calculations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号