首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Two methods which employ whole cells are described and compared for the detection of human IgG and IgM anti-brucella antibodies. Dot ELISA and ELISA were shown to be suitable for a screening diagnosis of human brucellosis. Titres of antibodies obtained by dot ELISA showed 100% coincidence for IgG and 97% for IgM, compared with agglutination and complement fixation tests; when ELISA was used 11% positive sera were not detected. The comparison of these two methods with the conventional serological test kit indicated that both dot ELISA and ELISA were sensitive, reproducible and specific for the quantification of IgG and IgM antibrucella antibodies.  相似文献   

2.
应用单克隆抗体测定人弓形虫IgM抗体的研究   总被引:2,自引:0,他引:2  
为了检测人血清弓形虫IgM抗体,采用抗人IgM单克隆抗体和特异性抗弓形虫单克隆抗体建立捕获ELISA法,并与PCR方法进行了比较。结果检测1065份献血员血清,检出阳性3例,用PCR方法检测呈阳性结果;检测23例类风湿病人血清及2份弓形虫IgG抗体阳性血清均为阴性反应。说明该方法不受类风湿因子(RF)和特异性IgG抗体的干扰,同时也表明捕获ELISA检测人血清中弓形虫IgM抗体特异性,敏感性良好。  相似文献   

3.
Crimean-Congo Hemorrhagic Fever Virus (CCHFV) is a geographically widespread tick-borne arbovirus that has been recognized by the WHO as an emerging pathogen needing urgent attention to ensure preparedness for potential outbreaks. Therefore, availability of accurate diagnostic tools for identification of acute cases is necessary.A panel comprising 121 sequential serum samples collected during acute, convalescent and subsided phase of PCR-proven CCHFV infection from 16 Kosovar patients was used to assess sensitivity. Serum samples from 60 healthy Kosovar blood donors were used to assess specificity. All samples were tested with two IgM/IgG immunofluorescence assays (IFA) from BNITM, the CCHFV Mosaic 2 IgG and IgM indirect immunofluorescence tests (IIFT) from EUROIMMUN, two BlackBox ELISAs for the detection of CCHFV-specific IgM and IgG antibodies (BNITM), two Anti-CCHFV ELISAs IgM and IgG from EUROIMMUN using recombinant structural proteins of CCHFV antigens, and two ELISAs from Vector-Best (IgM: μ-capture ELISA, IgG: indirect ELISA using immobilized CCHFV antigen). Diagnostic performances were compared between methods using sensitivity, specificity, concordance and degree of agreement with particular focus on the phase of the infection.In early and convalescent phases of infection, the sensitivities for detecting specific IgG antibodies differed for the ELISA test. The BlackBox IgG ELISA yielded the highest, followed by the EUROIMMUN IgG ELISA and finally the VectorBest IgG ELISA with the lowest sensitivities. In the subsided phase, the VectorBest IgM ELISA detected a high rate of samples that were positive for anti-CCHFV IgM antibodies. Both test systems based on immunofluorescence showed an identical sensitivity for detection of anti-CCHFV IgM antibodies in acute and convalescent phases of infection.Available serological test systems detect anti-CCHFV IgM and IgG antibodies accurately, but their diagnostic performances vary with respect to the phase of the infection.  相似文献   

4.
A new commercial anti-Japanese encephalitis virus IgM and IgG indirect immunofluorescence test (IIFT) was evaluated for the detection of the humoral immune response after Japanese encephalitis vaccination. The IgM IIFT was compared to two IgM capture ELISAs and the IgG IIFT was analysed in comparison to a plaque reduction neutralization test (PRNT50) and an IgG ELISA. Moreover, the course of the immune reaction after vaccination with an inactivated JEV vaccine was examined. For the present study 300 serum samples from different blood withdrawals from 100 persons vaccinated against Japanese encephalitis were used. For the IgM evaluation, altogether 78 PRNT50 positive samples taken 7 to 56 days after vaccination and 78 PRNT50 negative sera were analyzed with the Euroimmun anti-JEV IgM IIFT, the Panbio Japanese Encephalitis - Dengue IgM Combo ELISA and the InBios JE Detect IgM capture ELISA. For the IgG evaluation, 100 sera taken 56 days after vaccination and 100 corresponding sera taken before vaccination were tested in the PRNT50, the Euroimmun anti-JEV IgG IIFT, and the InBios JE Detect IgG ELISA. The Euroimmun IgM IIFT showed in comparison to the Panbio ELISA a specificity of 95% and a sensitivity of 86%. With respect to the InBios ELISA, the values were 100% and 83.9%, respectively. The analysis of the Euroimmun IgG IIFT performance and the PRNT50 results demonstrated a specificity of 100% and a sensitivity of 93.8%, whereas it was not possible to detect more than 6.6% of the PRNT50 positive sera as positive with the InBios JE Detect IgG ELISA. Thus, the IIFT is a valuable alternative to the established methods in detecting anti-JEV antibodies after vaccination in travellers and it might prove useful for the diagnosis of acutely infected persons.  相似文献   

5.
Toxoplasmosis has been well known as an important human infection to consider especially in pregnant women. Although many serologic methods are available, the diagnosis of toxoplasmosis can be extremely difficult. The presence of increased levels of Toxoplasma-specific IgG antibodies indicates an infection, but it does not differentiate between a recent and past infection. The purpose of our study was to compare the performance of the ELISA T. gondii IgG/IgM test, a widely used enzyme-linked immunosorbent assay, to the ELISA IgG avidity method. One hundred and four serum samples (from 38 males and 66 females) were tested and evaluated from symptomatic patients (chorioretinitis, lymphadenopathy), and from women in their first trimester of pregnancy who were suspected of having toxoplasmosis. The high IgG avidity and ELISA IgG antibody levels were in agreement for 51 of the specimens (49.0%). Thirty-eight discrepant (borderline) results from the IgG avidity method were positive for IgM (3 specimens) and IgG (37 specimens). Interestingly, out of the eight serum samples that were positive for both IgG and IgM antibodies, two samples were low IgG avidity, and three samples were borderline. There was no statistically significant relation observed between the results of the IgG avidity method and the ELISA IgG test, and the IgG avidity method and ELISA IgM test (chi2 = 1.987; p = 0.370 and chi2 = 2.152; p = 0.341, respectively). The IgG avidity method was considered easy to perform and an acceptable approach for the differentiation of discrepant results (recent/chronic) and for the current detection of T. gondii antibodies. We concluded that the determination of IgG avidity is a helpful tool for the diagnosis of the ocular form of toxoplasmosis and it is a safe method for screening this disease in the first trimester of pregnancy.  相似文献   

6.
Such cytomegalovirus antibodies as the IgG and IgM are investigated in the present work. Investigation was carried out on 301 sera of fertile aged women (between 18 to 35 years of age) under the enzyme-linked immunosorbent assay (ELISA). Only one dilution has been made i.e. 1:40 and the final dilution was worked out from regression graph obtained from a previously titred human positive serum analysis; IgG antibodies were found in 265 cases (88%), appearing IgM antibodies in 4 of them, with the remaining 36 cases showing neither IgG nor IgM antibodies (12%). These results were compared with those obtained in other countries and the importance of the serological diagnosis to this virus was pointed out.  相似文献   

7.
Keeping in view the complications and the case fatality associated with dengue virus, several serologic tests have been developed. However, the major drawback of these serologic tests is the need for a venous blood sample obtained by invasive venipuncture. As a noninvasive alternative, saliva provides a body fluid that contains antibodies of diagnostic importance. Hence, the detection of DEN-specific IgM and IgG antibodies in serum and saliva from 80 patients was compared. Salivary IgM antibodies were detected in 100% of the serum IgM-positive samples and in 30% of the serum samples that were negative for IgM antibodies. Salivary IgG antibodies were detected in 93.3% of the serum samples that were positive for anti-dengue IgG antibodies and in none of the serum IgG-negative cases. None of the specimens from the healthy controls showed the presence of IgM or IgG antibodies. The detection of both IgG and IgM antibodies in saliva correlated well with the serum IgG and IgM detection by the ELISA test (r = 0.6322 and r = 0.4227). Detection of salivary IgM antibodies by ELISA showed 100% sensitivity, 70% specificity, 90.9% positive predictive value, and 100% negative predictive value. The detection of IgG in saliva proved to be a promising tool as the sensitivity, specificity, positive predictive value, and negative predictive value were found out to be 93.3%, 100%, 100%, and 83.3%, respectively. Thus, from this study we conclude that the detection of DEN-specific salivary IgG and IgM antibodies are useful markers for dengue infection.  相似文献   

8.
Two new monoclonal antibodies, one a mouse IgM and the other a human IgM that reacted with guanosine, were compared to human serum antibodies from patients with systemic lupus erythematosus (SLE). The human monoclonal antibody was polyspecific in its binding to the nucleoside bases, whereas the mouse monoclonal antibody was relatively specific for guanosine when compared by using an enzyme-linked immunosorbent assay (ELISA). Neither antibody bound polyguanylic acid or denatured single-stranded (ss) DNA, however. Serum IgG antibodies from seven patients with SLE cross-reacted with the mouse monoclonal antibody and showed considerable specificity for guanosine. In contrast, the human serum IgG antiguanosine antibodies also bound ssDNA but not dsDNA or polyguanylic acid. Serum IgG antibodies to guanosine measured by ELISA from the seven SLE patients had a decreased response when compared to the total serum IgG response to ssDNA, and most of the antibodies that bound guanosine also bound ssDNA. These studies provide new evidence that there are specific IgG antibodies to guanosine in SLE sera that are a small fraction of the antibodies to ssDNA. Further efforts to define the role of these guanosine antibodies in SLE may provide a better understanding of the basic mechanisms responsible for the development of SLE in man.  相似文献   

9.
The usefulness of the methods was compared: complement fixation test (CFT), neutralization test (NT) and ELISA IgG and IgM against enteroviruses for the evaluation of specific immune reaction in sera and cerebrospinal fluid (CSF) samples of patients with confirmed enterovirus infections. The criteria were established for the assessment of ELISA results in rapid diagnosis of enterovirus neuroinfections. The criteria accepted by the producer lowered the sensitivity of the method and the possibility of recognition of local synthesis of antibodies in the CNS. The use of serum negative in CFT and negative CSF as reference for the determination made possible using of that kit for rapid diagnosis of neuroinfections. The modified ELISA IgG test makes possible determination of antibodies in CSF and serum, and accepting the generally recognized criteria for local production of antibodies in the CNS the ELISA test makes possible rapid diagnosis of neuroinfections which is not possible by other methods.  相似文献   

10.
Primary cytomegalovirus (CMV) infection during pregnancy often results in congenital CMV infection with severe clinical complications. IgM antibodies are one of the indices of primary infection. The IgG avidity index (AI) is also known to remain low for 3 months after primary infection. Here, we evaluated and compared the performance of CMV IgM and IgG avidity assays. Because sensitivity and specificity reportedly differ between CMV IgM kits, CMV IgM detection was compared between the two commercially available ELISA kits that are most commonly used in Japan. Sera for CMV IgM were first screened using a traditional indirect ELISA kit. Selected samples were then tested for CMV IgM and CMV AI using a CMV IgM‐capture ELISA kit and a CMV IgG avidity assay, respectively. The rate of concordance between the IgM kits was 89% (42/47), indicating the absence of any significant difference. Most of the CMV IgM‐positive plasma samples showed high CMV IgG AI; however, 18 commercially available plasma samples with low CMV IgG AI were all CMV IgM‐positive. One plausible explanation for this discrepancy is that the duration of low IgG AI is shorter than that of IgM positivity. Alternatively, CMV IgM tests may generate pseudo‐positive readouts in cases of congenital infection. Nevertheless, our study confirms that CMV IgG AI can be a reliable indicator of CMV primary infection.  相似文献   

11.
The usefulness of the ELISA distributed by BioChem ImmunoSystems, Medial Polska, Biomedica/Virotech and prepared in our laboratory (ELISA FH-K) for diagnosis of the M. pneumoniae infections was estimated. Eighty six serum samples obtained from 86 patients with respiratory tract infections were simultaneously tested by ELISA-IgM/-IgG and by complement fixation test which was accepted as a reference test. The highest sensitivity in relation to the CFT was displayed by the ELISA BioChem ImmunoSystems and Medial Polska (100%), slightly lower sensitivity by the ELISA Biomedica/Virotech--96.5% and ELISA FH-K--90.9% when determining mycoplasmal antibodies of IgM. The lowest sensitivity was displayed by the ELISA Biomedica/Virotech when determining antibodies of the IgG class (54.9%). The specificity of ELISA in relation to the CFT was generally higher when detecting mycoplasmal antibodies of the IgM class then of IgG class. The study demonstrated that all 4 ELISA may be used in routine serodiagnosis of M. pneumoniae infection. For the improve of sensitivity of ELISA it's recommended to measure simultaneously the level of mycoplasmal antibodies of IgM and IgG.  相似文献   

12.
An ELISA that measures anti‐PT IgG antibody has been used widely for the serodiagnosis of pertussis; however, the IgG‐based ELISA is inadequate for patients during the acute phase of the disease because of the slow response of anti‐PT IgG antibodies. To solve this problem, we developed a novel IgM‐capture ELISA that measures serum anti‐Bordetella pertussis Vag8 IgM levels for the accurate and early diagnosis of pertussis. First, we confirmed that Vag8 was highly expressed in all B. pertussis isolates tested (n = 30), but little or none in other Bordetella species, and that DTaP vaccines did not induce anti‐Vag8 IgG antibodies in mice (i.e. the antibody level could be unaffected by the vaccination). To determine the immune response to Vag8 in B. pertussis infection, anti‐Vag8 IgM levels were compared between 38 patients (acute phase of pertussis) and 29 healthy individuals using the anti‐Vag8 IgM‐capture ELISA. The results revealed that the anti‐Vag8 IgM levels were significantly higher in the patients compared with the healthy individuals (P < 0.001). ROC analysis also showed that the anti‐Vag8 IgM‐capture ELISA has higher diagnostic accuracy (AUC, 0.92) than a commercial anti‐PT IgG ELISA kit. Moreover, it was shown that anti‐Vag8 IgM antibodies were induced earlier than anti‐PT IgG antibodies on sequential patients’ sera. These data indicate that our novel anti‐Vag8 IgM‐capture ELISA is a potentially useful tool for making the accurate and early diagnosis of B. pertussis infection.  相似文献   

13.
Toxoplasma gondii is an obligate intracellular protozoan that is distributed worldwide. Recently, several tests for avidity of Toxoplasma IgG antibodies have been introduced to help discriminate between recently acquired and distant infections. The study was conducted in Jawaharlal Nehru Medical College and Hospital, India from February 2011 to September 2012. Serum specimens were subjected to Toxoplasma IgM ELISA and IgG avidity ELISA test. Out of 48 patients with abortions, 17 (35.4%) were positive for IgM ELISA, and 8 (16.6%) had low IgG avidity antibodies. Out of 48 patients with other obstetric problems, 23 (47.9%) were positive for IgM ELISA, and 17 (35.4%) had low IgG avidity antibodies. Combining both groups on avidity test, only 25 of 40 (62.5%) IgM-positive women had low-avidity IgG antibodies suggesting a recent T. gondii infection in these women. More importantly, 15 (37.5%) of the IgM-positive women had high-avidity antibodies suggesting that the infection was acquired before gestation The relation of IgM seropositivity with the following risk factors was not found to be statistically significant; contact with cats (0.13), non-vegetarian food habits (0.05), and low socio-economic status (0.49). While, for IgG avidity ELISA, only contact with cats (0.01) was significantly associated with seropositivity. All other risk factors have P-values of >0.05 (not significant). IgG avidity test when used in combination with IgM test was a valuable assay for diagnosis of ongoing or recently acquired T. gondii infection in India.  相似文献   

14.
The antibodies against the Enterobacterial Common Antigen (ECA) were detected using the ELISA in 293 serum samples collected from 185 persons suspected for yersiniosis, as well as 115 serum samples from healthy individuals (blood donors). The presence of IgA antibody in diagnostically significant titres for ECA were detected by ELISA in 3.5%, IgG in 13.0%, and IgM in 5.2% of blood donors. Statistical analysis showed that the frequency of detecting antibodies for ECA among the patients with yersiniosis was significantly higher (p < 0.05) in relation to the blood donors. Most frequently the elevated antibody levels were detected among patients with reactive arthritis (IgA 29.2%, IgG 35.4%, IgM 16.7%) while the most infrequent among patients with abdominal pain in acute phase of yersiniosis (IgA 14.9%, IgG 25.3%, IgM 19.5%). The level of antibodies for ECA, together with age increased reaching its peak, on the average, among individuals aged 41 - 60 years. In majority of the individuals studied antibodies of the IgG class reached the level much higher in relation to those of the IgA and IgM classes. The obtained results showed that the detection of antibodies to ECA may be useful in serodiagnosis of Yersinia infections.  相似文献   

15.
《Research in virology》1991,142(5):387-394
  • &#x02022;An enzyme-linked immunosorbent assay (ELISA) was developed to detect specific human immunoglobulin G and M antibodies to sandfly fever Sicilian (SFS) virus. Acute and early convalescent serum pairs with ⩾ 7 days between the 2 specimens were available from 20 patients and all showed significant optical density (OD) increase and significant titre rise (⩾ 4-fold) by IgG ELISA. However, negative or borderline-positive sera were found as late as 11 days after onset of symptoms when tested by IgG ELISA.
  • &#x02022;Specific IgM antibodies were detected during the first week of symptoms, and maximum OD values were obtained during the first 4 weeks after onset of disease. The IgM OD values declined over the following 3–9 months. All sera collected later than 14 months post-onset were negative by IgM ELISA.
  • &#x02022;The combination of early antibody response and the need to test only one serum specimen gives IgM ELISA an advantage over IgG ELISA in patient diagnosis.
  • &#x02022;The IgG ELISA was also evaluated as a seroepidemiological tool and compared to a plaque reduction neutralization test (PRNT) using sera from a normal Cypriot population. Of 183 sera tested, 34 (19%) were positive in plaque reduction neutralization tests (PRNT) and 113 (62%) by IgG ELISA. A number of PRNT-negative sera were strongly positive by IgG ELISA and also by indirect immunofluorescence test, which may suggest the presence of a virus related to SFS in Cyprus which has not yet been isolated.
  相似文献   

16.
The isotypic immune response of 16 individuals who developed Q fever pneumonia following exposure to an infected parturient cat was studied. The enzyme-linked immunosorbent (ELISA) test was used to detect IgM, IgA, and IgG antibodies to phase I and phase II Coxiella burnetii whole-cell antigens and to the phase I lipopolysaccharide. The indirect immunofluorescent antibody (IFA) test was also used to detect antibodies to phase I and phase II whole cells. None of the 16 subjects developed antibodies to the phase I lipopolysaccharide. The ELISA was more sensitive than the IFA test. IgM antibodies to phase II antigen were detectable by ELISA in 80% of the subjects at the time of onset of symptoms and were still present in 7 of the 8 tested at 32 weeks following the onset of symptoms. In all instances (ELISA: IgG, IgM; IFA: IgG, IgM) phase II antibodies developed earlier and reached higher levels than did phase I antibodies. The absence of antibodies to phase I lipopolysaccharide in acute Q fever combined with our unpublished findings of antibodies to phase I lipopolysaccharide in chronic Q fever suggests that this test may be used to distinguish acute from chronic Q fever.  相似文献   

17.
The seroprevalence of cryptosporidiosis was examined using patients'' sera collected from hospitals located in 4 different areas of the Republic of Korea. ELISA was used to measure antibody titers against Cryptosporidium parvum antigens from a total of 2,394 serum samples, which were collected randomly from patients in local hospitals; 1) Chungbuk National University Hospital, 2) Konkuk University Hospital, 3) local hospitals in Chuncheon, Gangwon-do (province), 4) Jeonnam National University Hospital, from 2002 through 2003. Of the 2,394 samples assayed, 34%, 26%, and 56% were positive for C. parvum-specific IgG, IgM, and IgA antibodies, respectively. Positive IgG titers were most common in sera from Jeonnam National University Hospital, Gwangju, Jeollanam-do, and positive IgM titers were most common in sera from Chungbuk National University Hospital, Cheongju, Chuncheongbuk-do. The seropositivity was positively correlated with age for both the IgG and IgA antibodies but was negatively correlated with age for the IgM antibodies. Western blotting revealed that 92%, 83%, and 77% of sera positive for IgG, IgM, and IgA ELISA reacted with 27-kDa antigens, respectively. These results suggested that infection with Cryptosporidium in hospital patients occurs more commonly than previously reported in the Republic of Korea.  相似文献   

18.
The aim of the present study was to determine the frequency of IgG, IgA, and IgM antibodies to Mycoplasma penetrans in HIV-1-infected patients and in patients with sexually transmitted diseases. We tested serum samples from 106 HIV-1-positive patients and 110 individuals with clinical symptoms of urethritis. ELISA and the immunoblot test were performed using M. penetrans lipid associated membrane proteins as antigen. By ELISA, we found a higher frequency (P < 0.05) of IgG against M. penetrans in HIV-1-infected and STD patients (25.5 and 17.3%) than in controls (1.2%), as well as a higher frequency of IgA (P < 0.05) (15.1 and 17.3% compared to 1.2%). For IgM, no differences were observed (P >/= 0.05) (3.8, 9.1, and 5. 8%, respectively). When the frequencies of IgG, IgM, and IgA antibodies of the HIV-1-infected patients were compared taking into account the CD4/CD8 cell ratios < 0.3 and >/= 0.3, no significant differences were observed between the two groups (13.3, 10, and 20%, compared to 20, 0, and 5%, respectively) (P > 0.05), possibly due to the low number of samples on which we could perform T-cell counts (53/106). The M. penetrans peptide of 38 kDa, considered immunodominant, was recognized in immunoblot by 51.8% of positive sera by ELISA for IgG, 50.0% for IgM, and 75% for IgA in the AIDS patients group, and by 47.4, 60.0, and 75.0%, respectively, in the sexually transmitted disease group. Cross-reactions in immunoblot for IgG were observed in sera from individuals infected with Mycoplasma pneumoniae and Mycoplasma hominis, and cross-reactions in immunoblot for IgA were observed in sera from individuals infected with M. hominis; all of them were ELISA negative to M. penetrans.  相似文献   

19.
For the detection of bacteria coated with immunoglobulins in urine the monoclonal antibodies against human IgA, IgG and IgM conjugated with peroxidase were used. For comparison, the immunofluorescence technique was also employed. The results obtained by two methods revealed that immunofluorescence were less sensitive. It was found that bacteria were predominantly coated with IgA (41,9 +/- 22,4%) and IgG (34,1 +/- 15,3 %) immunoglobulins. The IgM antibodies were found rarely (12,8 +/- 8%).  相似文献   

20.
There was followed the development of serological findings in patients with proved positivity only in classes IgA and/or IgM of chlamydial antibodies (without IgG), which can be suspected of showing "false" positivity. 184 patients were repeatedly examined for chlamydial antibodies in their sera (interval between collections up to three months) using a genus specific rELISA. Sera were also tested for the evidence of IgM antibodies against capside antigen of Epstein-Barr virus (EBV) and against cytomegalovirus (CMV) using ELISA methods. In 75 (40.8%) of patients, IgA/IgM individual positivities were demonstrated even during the following sample test(s). In 28 (15.2%) of them, IgG evidence preceded and in 29 (15.7%) other patients positive seroconversion followed in this class. In 13 (7.1%) patients, IgG antibodies disappeared and subsequently reappeared. Only in 39 (21.2%) of these probands, antibodies IgA/IgM were not demonstrated at another examination. Active EBV, resp. CMV infection was proved in 24 (13.0%), resp. in 18 (9.8%) of patients. It is concluded that the evidence of positivities only in classes IgA and/or IgM mostly signal the onset of a primary infection (reinfection) or an active infection in patients with IgG production failures respectively. In these cases, a "false" positivity can be supposed to occur only in a minor extent.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号