首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The most recent non-invasive methods for the recording of scapular motion are based on an acromion marker (AM) set and a single calibration (SC) of the scapula in a resting position. However, this method fails to accurately measure scapular kinematics above 90° of arm elevation, due to soft tissue artifacts of the skin and muscles covering the acromion. The aim of this study was to evaluate the accuracy, and inter-trial and inter-session repeatability of a double calibration method (DC) in comparison with SC. The SC and DC data were measured with an optoelectronic system during arm flexion and abduction at different angles of elevation (0-180°). They were compared with palpation of the scapula using a scapula locator. DC data was not significantly different from palpation for 5/6 axes of rotation tested (Y, X, and Z in abduction and flexion), where as SC showed significant differences for 5/6 axes. The root mean square errors ranged from 2.96° to 4.48° for DC and from 6° to 9.19° for SC. The inter-trial repeatability was good to excellent for SC and DC. The inter-session repeatability was moderate to excellent for SC and moderate to good for DC. Coupling AM and DC is an easy-to-use method, which yields accurate and reliable measurements of scapular kinematics for the complete range of arm motion. It can be applied to the measurement of shoulder motion in many fields (sports, orthopaedics, and rehabilitation), especially when large ranges of arm motion are required.  相似文献   

2.
Altered scapular motions premeditate shoulder impingement and other musculoskeletal disorders. Divergent experimental conditions in previous research precludes rigorous comparisons of non-invasive scapular tracking techniques. This study evaluated scapular orientation measurement methods across an expanded range of humeral postures. Scapular medial/lateral rotation, anterior/posterior tilt and protraction/retraction was measured using an acromion marker cluster (AMC), a scapular locator, and a reference stylus. Motion was captured using reflective markers on the upper body, as well as on the AMC, locator and stylus. A combination of 5 arm elevation angles, 3 arm elevation planes and 3 arm axial rotations was examined. Measurement method interacted with elevation angle and plane of elevation for all three scapular orientation directions (p < 0.01). Method of measurement interacted with axial rotation in anterior/posterior tilt and protraction/retraction (p < 0.01). The AMC had strong agreement with the reference stylus than the locator for the majority of humeral elevations, planes and axial rotations. The AMC underestimated lateral rotation, with the largest difference of ∼2° at 0° elevation. Both the locator and AMC overestimated posterior tilt at high arm elevation by up to 7.4°. Misestimations from using the locator could be enough to potentially obscure meaningful differences in scapular rotations.  相似文献   

3.
Identification of scapular dyskinesis and evaluation of interventions depend on the ability to properly measure scapulothoracic (ST) motion. The most widely used measurement approach is the acromion marker cluster (AMC), which can yield large errors in extreme humeral elevation and can be inaccurate in children and patient populations. Recently, an individualized regression approach has been proposed as an alternative to the AMC. This technique utilizes the relationship between ST orientation, humerothoracic orientation and acromion process position derived from calibration positions to predict dynamic ST orientations from humerothoracic and acromion process measures during motion. These individualized regressions demonstrated promising results for healthy adults; however, this method had not yet been compared to the more conventional AMC. This study compared ST orientation estimates by the AMC and regression approaches to static ST angles determined by surface markers placed on palpated landmarks in typically developing adolescents performing functional tasks. Both approaches produced errors within the range reported in the literature for skin-based scapular measurement techniques. The performance of the regression approach suffered when applied to positions outside of the range of motion in the set of calibration positions. The AMC significantly underestimated ST internal rotation across all positions and overestimated posterior tilt in some positions. Overall, root mean square errors for the regression approach were smaller than the AMC for every position across all axes of ST motion. Accordingly, we recommend the regression approach as a suitable technique for measuring ST kinematics in functional motion.  相似文献   

4.
The measurement of dynamic scapular kinematics is complex due to the sliding nature of the scapula beneath the skin surface. The aim of the study was to clearly describe the acromion marker cluster (AMC) method of determining scapular kinematics when using a passive marker motion capture system, with consideration for the sources of error which could affect the validity and reliability of measurements. The AMC method involves placing a cluster of markers over the posterior acromion, and through calibration of anatomical landmarks with respect to the marker cluster it is possible to obtain valid measurements of scapular kinematics. The reliability of the method was examined between two days in a group of 15 healthy individuals (aged 19-38 years, eight males) as they performed arm elevation, to 120°, and lowering in the frontal, scapular and sagittal planes. Results showed that between-day reliability was good for upward scapular rotation (Coefficient of Multiple Correlation; CMC = 0.92) and posterior tilt (CMC = 0.70) but fair for internal rotation (CMC = 0.53) during the arm elevation phase. The waveform error was lower for upward rotation (2.7° to 4.4°) and posterior tilt (1.3° to 2.8°), compared to internal rotation (5.4° to 7.3°). The reliability during the lowering phase was comparable to results observed during the elevation phase. If the protocol outlined in this study is adhered to, the AMC provides a reliable measurement of upward rotation and posterior tilt during the elevation and lowering phases of arm movement.  相似文献   

5.
This study determined the ratio between glenohumeral and three-dimensional scapular motion during arm elevation and lowering in 91 individuals without shoulder pain. Scapular kinematics were assessed using an electromagnetic tracking device. Individuals performed 3 repetitions of elevation and lowering of the arm in the sagittal plane. Two-way ANOVAs (interval: 30–60°, 60–90°, 90–120° x phase: elevation and lowering) and paired t-tests were used for data analysis. For scapular internal/external rotation, lesser scapular internal rotation contribution was found during the 60–90° interval as compared to the 90–60° interval. Lesser scapular external rotation was identified in the 60–30° interval of arm lowering. The ratio was greater during arm elevation (1.89) compared to lowering (1.74) across the entire motion arc. For scapular upward rotation, greater upward rotation contribution was observed during arm elevation at the 30–60° interval, and less scapular downward rotation contribution in the final range of arm lowering. For scapular tilt, lesser scapular posterior tilt contribution during arm elevation was observed compared to arm lowering. The ratios between glenohumeral elevation/lowering and each individual scapulothoracic motion showed either differences between intervals and/or between elevation and lowering during specific intervals in healthy individuals.  相似文献   

6.
PurposeThis study aimed to investigate the effect of elastic taping on kinematics, muscle activity and strength of the scapular region in baseball players with shoulder impingement.ScopeSeventeen baseball players with shoulder impingement were recruited from three amateur baseball teams. All subjects received both the elastic taping (Kinesio TexTM) and the placebo taping (3 M Micropore tape) over the lower trapezius muscle. We measured the 3-dimensional scapular motion, electromyographic (EMG) activities of the upper and lower trapezius, and the serratus anterior muscles during arm elevation. Strength of the lower trapezius was tested prior to and after each taping application. The results of the analyses of variance (ANOVA) with repeated measures showed that the elastic taping significantly increased the scapular posterior tilt at 30° and 60° during arm raising and increased the lower trapezius muscle activity in the 60–30° arm lowering phase (p < 0.05) in comparison to the placebo taping.ConclusionsThe elastic taping resulted in positive changes in scapular motion and muscle performance. The results supported its use as a treatment aid in managing shoulder impingement problems.  相似文献   

7.
The aim of this study was to investigate the applicability of the moiré fringe projection technique (MFPT) to quantify the scapular motions relative to the thorax. This system was composed of a LCD projector, a digital photographic camera, and a microcomputer. To automatically obtain the scapular profiles, the phase shifting method was combined with the MFPT. Four fringes were projected on the scapula and four on the reference planes. By the simple subtraction of the reference values from the scapular phase maps, the map due to the moiré fringes could be digitally obtained. After the phase decoding, the tridimensional (3D) profiles were obtained without prior information about the samples and the calculations of the scapular kinematics were carried out using dedicated software. On average, the movements of lateral rotation ranged from ?1.8±6.1° to ?26.5±3.5°; the protraction from 28.4±4.7° to 27.7±6.8°, and the posterior tilt from ?6.4±7.8° to ?21.7±6.1°, during the arm elevation in the scapular plane performed by six healthy subjects. For the test–retest reliability, the intra-class correlation coefficients ranged from 0.92 to 0.997 and the maximum estimated error was 0.8%. The MFPT allowed the scapular 3D measurements to be obtained in a digital and non-invasive manner. The main advantages compared with other existing systems were its ease in implementation, the use of standard optical components, and its possible clinical applications.  相似文献   

8.
The aim of this study is to determine the errors of scapular localisation due to skin relative to bone motion with an optoelectronic tracking system. We compared three-dimensional (3D) scapular positions obtained with skin markers to those obtained through palpation of three scapular anatomical landmarks. The scapular kinematics of nine subjects were collected. Static positions of the scapula were recorded with the right arm elevated at 0°, 40°, 80°, 120° and 160° in the sagittal plane. Palpation and subsequent digitisation of anatomical landmarks on scapula and thorax were done at the same positions. Scapular 3D orientation was also computed during 10 repeated movements of arm elevation between 0° and 180°. Significant differences in scapular kinematics were seen between static positions and palpation when considering anterior/posterior tilt and upward/downward rotation at angles over 120° of humeral elevation and only at 120° for internal/external rotation. There was no significant difference between positions computed during static positions and during the movement for the three scapular orientations. A rotation correction model is presented in order to reduce the errors between static position and palpation measurement.  相似文献   

9.
For kinematic studies of the shoulder, electromagnetic sensors are commonly placed on the humerus, scapula, and trunk. The trunk sensor is used to describe humeral and scapular kinematics with respect to the trunk. There are two common trunk sensor placements, the sternum or third thoracic vertebrae (T3). It is currently unclear if placement of the trunk sensor affects kinematics, making it difficult to compare data across studies. The purpose of this study was to compare two trunk sensor placements (T3 and sternum) on trunk and scapular kinematics during arm elevation. An electromagnetic tracking system was used to collect kinematic data during five consecutive repetitions of ascending and descending arm elevation in the sagittal plane. The results indicate that trunk sensor placement had no significant effect on trunk kinematics or scapular upward/downward rotation and internal/external rotation. Scapular anterior/posterior tilt was significantly greater when the trunk sensor was on the sternum compared to the T3 vertebrae during ascending 30°–120°: mean difference = −3.51° (95%CI: −5.61, −1.40), and descending 120°–30°: mean difference = −3.27° (95%CI: −6.07, −0.48). However, the difference in anterior/posterior tilt did not exceed the error (minimal detectable change), and thus is likely not a meaningful difference. These results indicate the trunk sensors can be affixed on T3 or the sternum, depending on the needs of the study.  相似文献   

10.
Characterization of scapular kinematics under demanding load conditions might aid to distinguish between physiological and clinically relevant alterations. Previous investigations focused only on submaximal external load situations. How scapular movement changes with maximal load remains unclear. Therefore, the present study aimed to evaluate 3D scapular kinematics during unloaded and maximal loaded shoulder flexion and extension. Twelve asymptomatic individuals performed shoulder flexion and extension movements under unloaded and maximal concentric and eccentric loaded isokinetic conditions. 3D scapular kinematics assessed with a motion capture system was analyzed for 20° intervals of humeral positions from 20° to 120° flexion. Repeated measures ANOVAs were used to evaluate kinematic differences between load conditions for scapular position angles, scapulohumeral rhythm and scapular motion extent. Increased scapular upward rotation was seen during shoulder flexion and extension as well as decreased posterior tilt and external rotation during eccentric and concentric arm descents of maximal loaded compared to unloaded conditions. Load effects were further seen for the scapulohumeral rhythm with greater scapular involvement at lower humeral positions and increased scapular motion extent under maximal loaded shoulder movements. With maximal load applied to the arm physiological scapular movement pattern are induced that may imply both impingement sparing and causing mechanisms.  相似文献   

11.
BackgroundThe scapula locator method has associated intra-observer and inter-observer errors caused by the dependency on the observer to locate the scapular landmarks. The potential effect of the pressures applied by the observer on the measured scapular kinematics when this method is used has also been overlooked so far. The aim of this study was to investigate the effect of using feedback on the pressures applied on the scapula using the locator on the intra-observer and inter-observer reliabilities of the method as well as on the kinematics obtained using this method.MethodsThree observers tracked the scapular motion of the dominant shoulder of each subject using the locator with no reference to pressure-feedback for three trials of bilateral elevation in the scapular plane and using the locator with pressure-feedback for three other trials. Variations between the measurements obtained were used to calculate the intra-observer errors and variations between the measurements obtained by the three observers for the same subject were used to calculate inter-observer errors. Repeated-measures ANOVA tests were used to look at differences between the two methods in terms of intra-observer and inter-observer errors and scapular kinematics.FindingsUsing pressure-feedback reduced the intra-observer errors but had no effect on the inter-observer errors. Different scapular kinematics was measured using the two methods.InterpretationsPressure-feedback improves the reliability of the scapula locator method. Differences in the scapular kinematics suggest that unregulated pressures have an effect on the physiological scapular motion.  相似文献   

12.
Optoelectronic tracking systems are rarely used in 3D studies examining shoulder movements including the scapula. Among the reasons is the important slippage of skin markers with respect to scapula. Methods using electromagnetic tracking devices are validated and frequently applied. Thus, the aim of this study was to develop a new method for in vivo optoelectronic scapular capture dealing with the accepted accuracy issues of validated methods.

Eleven arm positions in three anatomical planes were examined using five subjects in static mode. The method was based on local optimisation, and recalculation procedures were made using a set of five scapular surface markers.

The scapular rotations derived from the recalculation-based method yielded RMS errors comparable with the frequently used electromagnetic scapular methods (RMS up to 12.6° for 150° arm elevation). The results indicate that the present method can be used under careful considerations for 3D kinematical studies examining different shoulder movements.  相似文献   

13.
Scapular kinematics in healthy adults is well described in the literature but little is known on typical children. This study aimed to compare the three-dimensional (3-D) scapular kinematics and scapulohumeral rhythm during the elevation and lowering of the arm in the scapular plane in typical children and healthy adults. Twenty-six healthy adults (35.34 ± 11.65 years, 1.70 ± 0.10 m, 70.00 ± 12.30 kg) and 33 typical children (9.12 ± 1.51 years, 1.40 ± 0.10 m, 35.40 ± 10.45 kg) participated in this study. 3-D scapular kinematics were obtained using an electromagnetic tracking device. The subjects were asked to elevate and lower their arm in the scapular plane. Children showed less scapular protraction compared to adults at 120° during arm elevation, more anterior tilt than adults in the elevation and also at 60°, 90° and 120° during lowering of the arm. Children also showed higher scapulohumeral rhythm during lowering of the arm compared to adults from 90° to 60°. It was also found a low to little correlation between scapular position and age. The study showed small but significant differences in scapular kinematics and scapulohumeral rhythm between children and adults. These results can help clinicians to improve diagnosis and treatment protocols directed to children with dysfunction, as reference values on scapular kinematics in healthy children are also provided in this study.  相似文献   

14.
Non-invasive dynamical measurements of 3D scapular motion can be performed easily by attachment of a 6 DOF electromagnetic receiver onto the skin above the acromion. To quantify the introduction of possible errors due to skin displacement, we assessed 3D scapular positions on n=8 subjects by both tripod and skin-fixed method. Error analysis included the variables method (tripod, skin-fixed simultaneously with tripod, separate skin-fixed at 0 and 0.25Hz of elevation speed), plane of elevation (0 degrees and 90 degrees ) and observation (receiver replacement: n=3). Inter-individual 'group' differences depended on elevation plane and showed an average underestimation of scapular rotation of 6.5 degrees (worst case 13 degrees ) using the skin-fixed method. Only the group RMSE, not the individual RMSE, could be successfully lowered using linear regression (to about 2 degrees ). Inter-trial reliability (RMSE <3.24 degrees , ICC>0.94) and RMSE between 0 and 0.25Hz recordings (about 2.5 degrees ) were satisfactory. Intra-observer RMSE after replacement of the skin-fixed receiver was 5 degrees . The skin-fixed method is suitable for dynamic recordings of scapular rotations; however, measurements are precise only when the acromion receiver is not replaced. Combined with a relatively low accuracy, we conclude that the skin-fixed method should be used only in combination with tripod 'calibration'.  相似文献   

15.
The immediate goal of this study was to develop and validate a noninvasive, computational surface mapping approach for measuring scapular kinematics by using available motion capture technology in an innovative manner. The long-term goal is to facilitate clinical determination of the role of the scapula in children with brachial plexus birth palsy (BPBP). The population for this study consisted of fourteen healthy adults with prominent scapulae. Subject-specific scapular templates were created using the coordinates of five scapular landmarks obtained from palpation with subjects seated and arms relaxed in a neutral position. The scapular landmarks were re-palpated and their locations recorded in the six arm positions of the modified Mallet classification. The six Mallet positions were repeated with approximately 300 markers covering the scapula. The markers formed a surface map covering the tissue over the scapula. The scapular template created in the neutral position was iteratively fit to the surface map of each trial, providing an estimate of the orientation of the scapula. These estimates of scapular orientation were compared to the known scapular orientation determined from the scapular landmarks palpated in each Mallet position. The magnitude of the largest mean difference about an anatomical axis between the two measures of scapular orientation was 3.8° with an RMS error of 5.9°. This technique is practical for populations with visibly prominent scapulae (e.g., BPBP patients), for which it is a viable alternative to existing clinical methods with comparable accuracy.  相似文献   

16.
Conclusions about normal and pathologic shoulder motion are frequently made from studies using skin surface markers, yet accuracy of such sensors representing humeral motion is not well known. Nineteen subjects were investigated with flock of birds electromagnetic sensors attached to transcortical pins placed into the scapula and humerus, and a thermoplastic cuff secured on the arm. Subjects completed two repetitions of raising and lowering the arm in the sagittal, scapular and coronal planes, as well as shoulder internal and external rotation with the elbow at the side and abducted to 90°. Humeral motion was recorded simultaneously from surface and bone fixed sensors. The average magnitude of error was calculated for the surface and bone fixed measurements throughout the range of motion. ANOVA tested for differences across angles of elevation, raising and lowering, and differences in body mass index. For all five motions tested, the plane of elevation rotation average absolute error ranged from 0-2°, while the humeral elevation rotation average error ranged from 0-4°. The axial rotation average absolute error was much greater, ranging from 5° during elevation motions to approaching 30° at maximum excursion of internal/external rotation motions. Average absolute error was greater in subjects with body mass index greater than 25. Surface sensors are an accurate way of measuring humeral elevation rotations and plane of elevation rotations. Conversely, there is a large amount of average error for axial rotations when using a humeral cuff to measure glenohumeral internal/external rotation as the primary motion.  相似文献   

17.
Trunk rotation often accompanies humeral elevation, during daily activities as well as sports activities. Earlier studies have demonstrated that changes in spinal posture contribute to scapular motion during humeral elevation. However, the effect of trunk rotation on scapular kinematics during humeral elevation has received scant attention. This study aimed to clarify how trunk rotation affects scapular kinematics and muscle activities during humeral elevation. Electromagnetic motion capture and electromyography were used to assess scapular and clavicular motion and muscle activity in the right and left sides of 12 healthy young men. The subjects were seated and instructed to elevate both arms with the trunk in neutral, ipsilaterally rotated, or contralaterally rotated position. Ipsilaterally rotated trunk position decreased the internal rotation (by 5°, relative to neutral trunk position) and increased the upward rotation (by 4°, relative to neutral trunk position) of the scapula. Trunk position did not affect clavicular motion during humeral movement. Electromyography showed that contralaterally rotated trunk position increased the activity of the upper trapezius and serratus anterior muscles and decreased the activity of the lower trapezius. Therapists should consider the importance of trunk rotation, which may be the key to developing more efficient rehabilitation programs.  相似文献   

18.
BackgroundCurrent non-invasive 3-D scapular kinematic measurement techniques such as electromagnetic tracking are subjected to restrictions of wired sensors and limited capture space. Video-based motion analysis provides greater freedom with relatively less movement restriction. However, video-based motion analysis was rarely used in and not validated for scapular kinematics.MethodsScapular kinematics of five subjects performing abduction, scaption, and internal/external rotation was captured simultaneously with video-based motion analysis and dynamic stereo X-ray, a gold standard for tracking scapular movements. The data from video-based motion analysis was correlated with the data from dynamic stereo X-ray for validity evaluation.FindingsStrong and significant correlations were identified in scapular protraction/retraction and medial/lateral rotation during abduction and scaption, and scapular medial/lateral rotation and anterior/posterior tilt during internal/external rotation.InterpretationVideo-based motion analysis is valid for evaluating a single subject's scapular movement pattern in protraction/retraction during abduction and scaption, and medial/lateral-rotation during internal/external rotation. Anterior/posterior-tilt during abduction and scaption should be investigated with caution. Video motion analysis is also valid for evaluating group average of scapular kinematics except for protraction/retraction during internal/external rotation. While acknowledging the inherent limitations, video-based motion analysis is an appropriate technique for tracking scapular kinematics.  相似文献   

19.
The purpose was to compare glenohumeral (GH) migration, during dynamic shoulder elevation and statically held positions using digital fluoroscopic videos (DFV). Thirty male volunteers (25±4 years) without right shoulder pathology were analyzed using DFV (30 Hz) during arm elevation in the scapular plane. DFV were obtained at the arm at side position, 45°, 90°, and 135° for static and dynamic conditions. GH migration was measured as the distance from the center of the humeral head migrated superiorly or inferiorly relative to the center of the glenoid fossa. Inter-rater reliability was considered good; ICC (2,3) ranged from 0.83 to 0.92. A main effect was revealed for contraction type (p=0.031), in which post-hoc t-tests revealed that humeral head was significantly more superior on the glenoid fossa during dynamic contraction. A main effect was also revealed for arm angle (p<0.001), in which post-hoc t-tests revealed significantly more superior humeral head positioning at 45°, 90°, and 135° when compared to arm at side (p<0.001), as well as at 90° compared to 45° (p=0.024). There was no interaction effect between angle and contraction type (p=0.400). Research utilizing static imaging may underestimate the amount of superior GH migration that occurs dynamically.  相似文献   

20.
Modern virtual reality systems such as the HTC Vive enable users to be immersed in a virtual world. Validation of the HTC Vive and other contemporaneous systems for use in clinic, research, and industry applications will assure users and developers that games and applications made for these systems are accurate representations of the real world. The purpose of this study was to develop a standardized method for testing the translational and rotational capabilities of VR systems such as the HTC Vive. The translational and rotational capabilities of the HTC Vive were investigated using an industry grade robot arm and a gold standard motion capture system. It was found that the average difference between reported translational distances traveled was 0.74 ± 0.42 mm for all room-scale calibration trials and 0.63 ± 0.27 mm for all standing calibration trials. The mean difference in angle rotated was 0.46 ± 0.46° for all room-scale calibration trials and 0.66 ± 0.40° for all standing calibration trials. When tested using human movement, the average difference in distance traveled was 3.97 ± 3.37 mm. Overall, the HTC Vive shows promise as a tool for clinic, research, and industry and its controllers can be accurately tracked in a variety of situations. The methodology used for this study can easily be replicated for other VR systems so that direct comparisons can be made as new systems become available.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号