首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aim of this study is to determine the errors of scapular localisation due to skin relative to bone motion with an optoelectronic tracking system. We compared three-dimensional (3D) scapular positions obtained with skin markers to those obtained through palpation of three scapular anatomical landmarks. The scapular kinematics of nine subjects were collected. Static positions of the scapula were recorded with the right arm elevated at 0°, 40°, 80°, 120° and 160° in the sagittal plane. Palpation and subsequent digitisation of anatomical landmarks on scapula and thorax were done at the same positions. Scapular 3D orientation was also computed during 10 repeated movements of arm elevation between 0° and 180°. Significant differences in scapular kinematics were seen between static positions and palpation when considering anterior/posterior tilt and upward/downward rotation at angles over 120° of humeral elevation and only at 120° for internal/external rotation. There was no significant difference between positions computed during static positions and during the movement for the three scapular orientations. A rotation correction model is presented in order to reduce the errors between static position and palpation measurement.  相似文献   

2.
The measurement of dynamic scapular kinematics is complex due to the sliding nature of the scapula beneath the skin surface. The aim of the study was to clearly describe the acromion marker cluster (AMC) method of determining scapular kinematics when using a passive marker motion capture system, with consideration for the sources of error which could affect the validity and reliability of measurements. The AMC method involves placing a cluster of markers over the posterior acromion, and through calibration of anatomical landmarks with respect to the marker cluster it is possible to obtain valid measurements of scapular kinematics. The reliability of the method was examined between two days in a group of 15 healthy individuals (aged 19-38 years, eight males) as they performed arm elevation, to 120°, and lowering in the frontal, scapular and sagittal planes. Results showed that between-day reliability was good for upward scapular rotation (Coefficient of Multiple Correlation; CMC = 0.92) and posterior tilt (CMC = 0.70) but fair for internal rotation (CMC = 0.53) during the arm elevation phase. The waveform error was lower for upward rotation (2.7° to 4.4°) and posterior tilt (1.3° to 2.8°), compared to internal rotation (5.4° to 7.3°). The reliability during the lowering phase was comparable to results observed during the elevation phase. If the protocol outlined in this study is adhered to, the AMC provides a reliable measurement of upward rotation and posterior tilt during the elevation and lowering phases of arm movement.  相似文献   

3.
For kinematic studies of the shoulder, electromagnetic sensors are commonly placed on the humerus, scapula, and trunk. The trunk sensor is used to describe humeral and scapular kinematics with respect to the trunk. There are two common trunk sensor placements, the sternum or third thoracic vertebrae (T3). It is currently unclear if placement of the trunk sensor affects kinematics, making it difficult to compare data across studies. The purpose of this study was to compare two trunk sensor placements (T3 and sternum) on trunk and scapular kinematics during arm elevation. An electromagnetic tracking system was used to collect kinematic data during five consecutive repetitions of ascending and descending arm elevation in the sagittal plane. The results indicate that trunk sensor placement had no significant effect on trunk kinematics or scapular upward/downward rotation and internal/external rotation. Scapular anterior/posterior tilt was significantly greater when the trunk sensor was on the sternum compared to the T3 vertebrae during ascending 30°–120°: mean difference = −3.51° (95%CI: −5.61, −1.40), and descending 120°–30°: mean difference = −3.27° (95%CI: −6.07, −0.48). However, the difference in anterior/posterior tilt did not exceed the error (minimal detectable change), and thus is likely not a meaningful difference. These results indicate the trunk sensors can be affixed on T3 or the sternum, depending on the needs of the study.  相似文献   

4.
Characterization of scapular kinematics under demanding load conditions might aid to distinguish between physiological and clinically relevant alterations. Previous investigations focused only on submaximal external load situations. How scapular movement changes with maximal load remains unclear. Therefore, the present study aimed to evaluate 3D scapular kinematics during unloaded and maximal loaded shoulder flexion and extension. Twelve asymptomatic individuals performed shoulder flexion and extension movements under unloaded and maximal concentric and eccentric loaded isokinetic conditions. 3D scapular kinematics assessed with a motion capture system was analyzed for 20° intervals of humeral positions from 20° to 120° flexion. Repeated measures ANOVAs were used to evaluate kinematic differences between load conditions for scapular position angles, scapulohumeral rhythm and scapular motion extent. Increased scapular upward rotation was seen during shoulder flexion and extension as well as decreased posterior tilt and external rotation during eccentric and concentric arm descents of maximal loaded compared to unloaded conditions. Load effects were further seen for the scapulohumeral rhythm with greater scapular involvement at lower humeral positions and increased scapular motion extent under maximal loaded shoulder movements. With maximal load applied to the arm physiological scapular movement pattern are induced that may imply both impingement sparing and causing mechanisms.  相似文献   

5.
PurposeThis study aimed to investigate the effect of elastic taping on kinematics, muscle activity and strength of the scapular region in baseball players with shoulder impingement.ScopeSeventeen baseball players with shoulder impingement were recruited from three amateur baseball teams. All subjects received both the elastic taping (Kinesio TexTM) and the placebo taping (3 M Micropore tape) over the lower trapezius muscle. We measured the 3-dimensional scapular motion, electromyographic (EMG) activities of the upper and lower trapezius, and the serratus anterior muscles during arm elevation. Strength of the lower trapezius was tested prior to and after each taping application. The results of the analyses of variance (ANOVA) with repeated measures showed that the elastic taping significantly increased the scapular posterior tilt at 30° and 60° during arm raising and increased the lower trapezius muscle activity in the 60–30° arm lowering phase (p < 0.05) in comparison to the placebo taping.ConclusionsThe elastic taping resulted in positive changes in scapular motion and muscle performance. The results supported its use as a treatment aid in managing shoulder impingement problems.  相似文献   

6.
Conclusions about normal and pathologic shoulder motion are frequently made from studies using skin surface markers, yet accuracy of such sensors representing humeral motion is not well known. Nineteen subjects were investigated with flock of birds electromagnetic sensors attached to transcortical pins placed into the scapula and humerus, and a thermoplastic cuff secured on the arm. Subjects completed two repetitions of raising and lowering the arm in the sagittal, scapular and coronal planes, as well as shoulder internal and external rotation with the elbow at the side and abducted to 90°. Humeral motion was recorded simultaneously from surface and bone fixed sensors. The average magnitude of error was calculated for the surface and bone fixed measurements throughout the range of motion. ANOVA tested for differences across angles of elevation, raising and lowering, and differences in body mass index. For all five motions tested, the plane of elevation rotation average absolute error ranged from 0-2°, while the humeral elevation rotation average error ranged from 0-4°. The axial rotation average absolute error was much greater, ranging from 5° during elevation motions to approaching 30° at maximum excursion of internal/external rotation motions. Average absolute error was greater in subjects with body mass index greater than 25. Surface sensors are an accurate way of measuring humeral elevation rotations and plane of elevation rotations. Conversely, there is a large amount of average error for axial rotations when using a humeral cuff to measure glenohumeral internal/external rotation as the primary motion.  相似文献   

7.
Scapular kinematics in healthy adults is well described in the literature but little is known on typical children. This study aimed to compare the three-dimensional (3-D) scapular kinematics and scapulohumeral rhythm during the elevation and lowering of the arm in the scapular plane in typical children and healthy adults. Twenty-six healthy adults (35.34 ± 11.65 years, 1.70 ± 0.10 m, 70.00 ± 12.30 kg) and 33 typical children (9.12 ± 1.51 years, 1.40 ± 0.10 m, 35.40 ± 10.45 kg) participated in this study. 3-D scapular kinematics were obtained using an electromagnetic tracking device. The subjects were asked to elevate and lower their arm in the scapular plane. Children showed less scapular protraction compared to adults at 120° during arm elevation, more anterior tilt than adults in the elevation and also at 60°, 90° and 120° during lowering of the arm. Children also showed higher scapulohumeral rhythm during lowering of the arm compared to adults from 90° to 60°. It was also found a low to little correlation between scapular position and age. The study showed small but significant differences in scapular kinematics and scapulohumeral rhythm between children and adults. These results can help clinicians to improve diagnosis and treatment protocols directed to children with dysfunction, as reference values on scapular kinematics in healthy children are also provided in this study.  相似文献   

8.
Altered scapular motions premeditate shoulder impingement and other musculoskeletal disorders. Divergent experimental conditions in previous research precludes rigorous comparisons of non-invasive scapular tracking techniques. This study evaluated scapular orientation measurement methods across an expanded range of humeral postures. Scapular medial/lateral rotation, anterior/posterior tilt and protraction/retraction was measured using an acromion marker cluster (AMC), a scapular locator, and a reference stylus. Motion was captured using reflective markers on the upper body, as well as on the AMC, locator and stylus. A combination of 5 arm elevation angles, 3 arm elevation planes and 3 arm axial rotations was examined. Measurement method interacted with elevation angle and plane of elevation for all three scapular orientation directions (p < 0.01). Method of measurement interacted with axial rotation in anterior/posterior tilt and protraction/retraction (p < 0.01). The AMC had strong agreement with the reference stylus than the locator for the majority of humeral elevations, planes and axial rotations. The AMC underestimated lateral rotation, with the largest difference of ∼2° at 0° elevation. Both the locator and AMC overestimated posterior tilt at high arm elevation by up to 7.4°. Misestimations from using the locator could be enough to potentially obscure meaningful differences in scapular rotations.  相似文献   

9.
Trunk rotation often accompanies humeral elevation, during daily activities as well as sports activities. Earlier studies have demonstrated that changes in spinal posture contribute to scapular motion during humeral elevation. However, the effect of trunk rotation on scapular kinematics during humeral elevation has received scant attention. This study aimed to clarify how trunk rotation affects scapular kinematics and muscle activities during humeral elevation. Electromagnetic motion capture and electromyography were used to assess scapular and clavicular motion and muscle activity in the right and left sides of 12 healthy young men. The subjects were seated and instructed to elevate both arms with the trunk in neutral, ipsilaterally rotated, or contralaterally rotated position. Ipsilaterally rotated trunk position decreased the internal rotation (by 5°, relative to neutral trunk position) and increased the upward rotation (by 4°, relative to neutral trunk position) of the scapula. Trunk position did not affect clavicular motion during humeral movement. Electromyography showed that contralaterally rotated trunk position increased the activity of the upper trapezius and serratus anterior muscles and decreased the activity of the lower trapezius. Therapists should consider the importance of trunk rotation, which may be the key to developing more efficient rehabilitation programs.  相似文献   

10.
11.
The aim of this study was to assess the reliability and validity of a modified two-dimensional electrical inclinometer to measure scapular upward rotation during static humeral elevation. Numerous techniques have been proposed to qualitatively and quantitatively measure upward rotation of the scapula. These techniques are limited by expense or an inability to be synchronized with other measurements, such as muscle activity and force output. For validity testing, static scapular upward rotation was measured separately with a digital protractor and electrical inclinometer while participants were at rest and 60°, 90° and 120° of humeral elevation in the scapular plane. For reliability testing, either 20 min before or 20 min after validity testing, participants performed the testing positions while measurements were taken with the electrical inclinometer only. Significant correlations existed between the modified electrical inclinometer and digital protractor at all four positions (r>0.996, p<0.001). The electrical inclinometer demonstrated good to excellent intra-rater reliability (ICC(3,1)>0.892, 95%CI: 0.785-0.988 and SEM<1.8°). These results support the use of the electrical inclinometer to measure scapular upward rotation. These findings provide clinicians and researchers with a practical instrument that can accurately measure scapular upward rotation in synchrony with other measurements, such as electromyography and isokinetic data.  相似文献   

12.
We aimed to describe 3D scapular kinematics and scapulohumeral rhythm (SHR) in glenohumeral (GH) osteoarthritis shoulders compared to unaffected shoulders and to compare the abnormal scapular kinematic schema for GH osteoarthritis with that for frozen shoulder. Thirty-two patients with stiff shoulder (16 with GH osteoarthritis and 16 with frozen shoulder) performed maximal arm elevation in two planes, sagittal and frontal. Scapular rotations and humeral elevation of the affected and unaffected shoulders were measured by the Polhemus Fastrak electromagnetic system. Patients with GH osteoarthritis were older, had longer disease duration (p<0.001) and less restricted humeral elevation in the frontal plane (p=0.01). Protraction was significantly lower for the affected shoulders except for arm elevation in the frontal plane in the GH osteoarthritis group. Furthermore, protraction was lower with frozen shoulder than GH osteoarthritis during arm elevation in the frontal plane. Scapular lateral rotation and SHR were significantly higher for the affected shoulders in both groups whatever the plane of elevation. SHR showed a fair to moderate negative correlation with maximal humeral elevation in both groups and appears to be higher with frozen shoulder than GH osteoarthritis. In addition, SHR of the affected shoulder showed a fair to moderate correlation with disease duration only with GH osteoarthritis. Scapular tilt did not differ between affected and unaffected sides and was not influenced by type of disease. In conclusion, the increased scapular lateral rotation described in frozen shoulder is also observed in GH osteoarthritis. SHR of the affected shoulder is inversely related to severity of limitation of shoulder range of motion, which suggests a compensatory pattern.  相似文献   

13.
IntroductionThe acromion marker cluster (AMC) is a non-invasive scapular motion tracking method. However, it lacks testing in clinical populations, where unique challenges may present. This investigation resolved the utility of the AMC approach in a compromised clinical population.MethodsThe upper body of breast cancer survivors (BCS) and controls were tracked via motion capture and scapular landmarks palpated and recorded using a digitizer at static neutral to maximum elevation postures. The AMC tracked the scapula during dynamic maximum arm abduction. Both single (SC) and double calibration (DC) methods were applied to calculate scapular angles. The influences of calibration method, elevation, and group on mean and absolute error with two-way fixed ANOVAs with interactions (p < 0.05). Root mean square errors (RMSE) were calculated and compared.ResultsDC improved AMC estimation of palpated scapular orientation over SC, especially at higher arm elevations; RMSE averaged 11° higher for SC than DC at maximum elevation, but the methods were only 2.2° different at 90° elevation. DC of the AMC yielded mean error values of ∼5–10°. These approximate errors reported for AMC with young, lean adults.ConclusionsThe AMC with DC is a non-invasive method with acceptable error for measuring scapular motion of BCS and age-matched controls.  相似文献   

14.
This study described the three-dimensional shoulder motion during the arm elevation in individuals with isolated acromioclavicular osteoarthritis (ACO) and ACO associated with rotator cuff disease (RCD), as compared to controls. Seventy-four participants (ACO = 23, ACO + RCD = 25, Controls = 26) took part of this study. Disability was assessed with the DASH, three-dimensional kinematics were collected during arm elevation in the sagittal and scapular planes, and pain was assessed with the 11-point numeric pain rating scale. For each kinematic variable and demographic variables, separate linear mixed-model 2-way ANOVAs were performed to compare groups. Both ACO groups had higher DASH and pain scores. At the scapulothoracic joint, the isolated ACO group had greater internal rotation than control, and the ACO + RCD group had greater upward rotation than both other groups. At the sternoclavicular joint, both groups with ACO had less retraction, and the isolated ACO group had less elevation and posterior rotation. At the acromioclavicular joint, the isolated ACO group had greater upward rotation, and both ACO groups had greater posterior tilting. Patients with ACO had altered shoulder kinematics, which may represent compensatory responses to reduce pain and facilitate arm motion during arm elevation and lowering.  相似文献   

15.
Scapula and humerus motion associated with common manual wheelchair tasks is hypothesized to reduce the subacromial space. However, previous work relied on either marker-based motion capture for kinematic measures, which is prone to skin-motion artifact; or ultrasound imaging for arthrokinematic measures, which are 2D and acquired in statically-held positions. The aim of this study was to use a fluoroscopy-based approach to accurately quantify glenohumeral kinematics during manual wheelchair use, and compare tasks for a subset of parameters theorized to be associated with mechanical impingement. Biplane images of the dominant shoulder were acquired during scapular plane elevation, propulsion, sideways lean, and weight-relief raise in ten manual wheelchair users with spinal cord injury. A computed tomography scan of the shoulder was obtained, and model-based tracking was used to quantify six-degree-of-freedom glenohumeral kinematics. Axial rotation and superior/inferior and anterior/posterior humeral head positions were characterized for full activity cycles and compared between tasks. The change in the subacromial space was also determined for the period of each task defined by maximal change in the aforementioned parameters. Propulsion, sideways lean, and weight-relief raise, but not scapular plane elevation, were marked by mean internal rotation (8.1°, 10.8°, 14.7°, −49.2° respectively). On average, the humeral head was most superiorly positioned during the weight-relief raise (1.6 ± 0.9 mm), but not significantly different from the sideways lean (0.8 ± 1.1 mm) (p = 0.191), and much of the task was characterized by inferior translation. Scaption was the only task without a defined period of superior translation on average. Pairwise comparisons revealed no significant differences between tasks for anterior/posterior position (task means range: 0.1–1.7 mm), but each task exhibited defined periods of anterior translation. There was not a consistent trend across tasks between internal rotation, superior translation, and anterior translation with reductions in the subacromial space. Further research is warranted to determine the likelihood of mechanical impingement during these tasks based on the measured task kinematics and reductions in the subacromial space.  相似文献   

16.
The aim of this study was to investigate the applicability of the moiré fringe projection technique (MFPT) to quantify the scapular motions relative to the thorax. This system was composed of a LCD projector, a digital photographic camera, and a microcomputer. To automatically obtain the scapular profiles, the phase shifting method was combined with the MFPT. Four fringes were projected on the scapula and four on the reference planes. By the simple subtraction of the reference values from the scapular phase maps, the map due to the moiré fringes could be digitally obtained. After the phase decoding, the tridimensional (3D) profiles were obtained without prior information about the samples and the calculations of the scapular kinematics were carried out using dedicated software. On average, the movements of lateral rotation ranged from ?1.8±6.1° to ?26.5±3.5°; the protraction from 28.4±4.7° to 27.7±6.8°, and the posterior tilt from ?6.4±7.8° to ?21.7±6.1°, during the arm elevation in the scapular plane performed by six healthy subjects. For the test–retest reliability, the intra-class correlation coefficients ranged from 0.92 to 0.997 and the maximum estimated error was 0.8%. The MFPT allowed the scapular 3D measurements to be obtained in a digital and non-invasive manner. The main advantages compared with other existing systems were its ease in implementation, the use of standard optical components, and its possible clinical applications.  相似文献   

17.
There is a lack of studies of 3D scapular kinematic patterns for patients with shoulder conditions comparing affected and contralateral nonaffected shoulders during self-care activities of daily living (ADL). In this study, we compared 48 patients - 11 with glenohumeral osteoarthritis (GHOA), 20 with frozen shoulder (FS) and 17 with rotator cuff tendinopathies (RCT) - as they performed two ADL: hair combing and back washing. 3D scapular rotations and humerothoracic elevation (HTE) of the affected and contralateral nonaffected shoulders were recorded with use of a 6 degrees-of-freedom electromagnetic device. The HTE of affected and nonaffected shoulders were compared for each pathology group at rest and at the HTE used to perform the ADL: 30°, 45° and 60° of HTE for hair combing, and 30° of HT elevation for back washing. For hair combing, mean peak HTE was significantly lower for affected than nonaffected shoulders. Mean scapular lateral rotation was significantly greater at each HTE degree for GHOA and RCT groups, and mean scapular posterior tilt was significantly lower at 30° of HTE for the FS group. For back washing, mean peak HTE was lower for affected than nonaffected shoulders for the FS group only. Mean scapular medial rotation was significantly lower at 30° of HTE for the RCT group. 3D scapular kinematics appear to be specific to the shoulder pathology and to the task studied. Specific scapular kinematic patterns must be considered for appropriate therapeutic management.  相似文献   

18.
The purpose of this study was to assess the effect of standardized anterior glenohumeral capsular lesions on axial humeral rotation in a full arc of glenohumeral elevation. Using a testing apparatus, the range of internal and external humeral rotation was assessed in an arc of glenohumeral elevation in the scapular plane with steps of 15 degrees in six isolated shoulder joint specimens. Cutting of the glenohumeral joint capsule 1 cm laterally from, and parallel to the glenoid rim was performed in seven steps of 1 cm till the anterior capsule was cut. Capsular lesions were made in three ways: from inferior, from superior and from the middle of the capsule. Anterior capsular lesions resulted in significant increase of external humeral rotation. This occurred particularly at 15-60 degrees glenohumeral elevation. Lesions of the inferior part of the capsule mainly increased external rotation at 30-60 degrees glenohumeral elevation, lesions of the superior part mainly in lower elevation angles and lesions of the middle more gradually in the range till 60 degrees of glenohumeral elevation. Cutting of the anterior glenohumeral capsule barely increased passive axial humeral rotation at elevation angles over 60 degrees. Above 60 degrees glenohumeral elevation, tightening of the inferior posterior glenohumeral joint capsule prevented both internal and, increasingly, external humeral rotation. From these observations it is concluded that increased external rotation correlates with progressive anterior capsular lesions, mainly below 60 degrees glenohumeral elevation. To assess anterior glenohumeral capsular lesions in patients, axial humeral rotation tests should probably not exceed 60 degrees glenohumeral elevation, i.e. 90 degrees thoracohumeral elevation.  相似文献   

19.
It is currently unknown in which ways activity of the ab- and adductor shoulder muscles affects shoulder biomechanics (scapular kinematics and glenohumeral translation), and whether these changes are relevant for alterations of the subacromial space width. The objective of this experimental in vivo study was thus to test the hypotheses that potential changes of the subacromial space width (during antagonistic muscle activity) are caused by alterations of scapular kinematics and/or glenohumeral translation. The shoulders of 12 healthy subjects were investigated with an open MRI-system at 30 degrees, 60 degrees, 90 degrees, 120 degrees and 150 degrees of arm elevation. A force of 15N was applied to the distal humerus, once causing isometric contraction of the abductors and once contraction of the adductors. The scapulo-humeral rhythm, scapular tilting and glenohumeral translation were calculated from the MR image data for both abducting and adducting muscle activity. Adducting muscle activity led to significant increase of the subacromial space width in all arm positions. The scapulo-humeral rhythm (2.2-2.5) and scapular tilting (2-4 degrees) remained relatively constant during elevation, no significant difference was found between abducting and adducting muscle activity. The position of the humerus relative to the glenoid was, however, significantly (p < 0.05) different (inferior and anterior) for adducting versus abducting muscle activity in midrange elevation (60-120 degrees). These data show that the subacromial space can be effectively widened by adducting muscle activity, by affecting the position of the humerus relative to the glenoid. This effect may be employed for conservative treatment of the impingement syndrome.  相似文献   

20.
The purpose was to compare glenohumeral (GH) migration, during dynamic shoulder elevation and statically held positions using digital fluoroscopic videos (DFV). Thirty male volunteers (25±4 years) without right shoulder pathology were analyzed using DFV (30 Hz) during arm elevation in the scapular plane. DFV were obtained at the arm at side position, 45°, 90°, and 135° for static and dynamic conditions. GH migration was measured as the distance from the center of the humeral head migrated superiorly or inferiorly relative to the center of the glenoid fossa. Inter-rater reliability was considered good; ICC (2,3) ranged from 0.83 to 0.92. A main effect was revealed for contraction type (p=0.031), in which post-hoc t-tests revealed that humeral head was significantly more superior on the glenoid fossa during dynamic contraction. A main effect was also revealed for arm angle (p<0.001), in which post-hoc t-tests revealed significantly more superior humeral head positioning at 45°, 90°, and 135° when compared to arm at side (p<0.001), as well as at 90° compared to 45° (p=0.024). There was no interaction effect between angle and contraction type (p=0.400). Research utilizing static imaging may underestimate the amount of superior GH migration that occurs dynamically.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号