首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A study is made of the boundary regions of magnetic structures formed either near the last closed flux surface of the main magnetic configuration in a stellarator or near magnetic islands in more general toroidal confinement systems with topologically equivalent sheared magnetic configurations. With a relatively simple approximate analytic model based on the perturbation method, it was possible not only to reproduce earlier results on the destruction of hyperbolic magnetic axes in the three-dimensional toroidal magnetic configurations under consideration but also to obtain some new results, in particular, to analytically estimate the sizes of the separatrix regions of stochastic magnetic fields that arise in the main stellarator configuration and also near the inner chains of magnetic islands in any magnetic configuration under consideration. It is notable that the boundary region of the main stellarator magnetic configuration is a multiply connected structure, the outer part of which is largely governed by the current distribution in the magnetic system creating this configuration.  相似文献   

2.
磁性细菌胞内可以产生磁性颗粒,因此具有趋磁性,基于这种特性,利用磁分离的原理,本研究开发了一种磁性细菌分离仪,提供了一种分离磁性细菌的新方法。以氧化亚铁硫杆菌为例,使用磁性细菌分离仪进行分离,可以得到强磁菌和弱磁菌。利用透射电镜观察,强磁菌胞内磁性颗粒明显多于弱磁菌;半固体平板磁泳实验也表明强磁菌趋磁性明显强于弱磁菌。各项实验结果表明磁性细菌分离仪可以有效地分离磁性细菌,这是一种分离磁性细菌的新方法,将促进磁性细菌分离培养的研究。  相似文献   

3.
High gradient magnetic separation of yeast   总被引:3,自引:0,他引:3  
High gradient magnetic separation (HGMS) is used to separate nonmagnetic microorganisms from solution by a technique known as seeding. Fine magnetic particles are adhered to the cells' surfaces, making them magnetic and amenable to magnetic separation. Attachment of the sub-micron, acicular gamma-Fe(2)O(3) seed to the yeast surface occurs irrespective of the solution pH and surface charge and is essentially irreversible. A model is developed to predict the separation of yeast in a high gradient magnetic separator. The effective capture radius is assumed to be proportional to the derived magnetic parameter gamma for the case where the dominant competing force to magnetic attraction is the magnetic floc's inertia. Using this parameter, yeast separation in an HGMS unit is predicted. The measured separation of Saccharomyces cerevisiae at differing magnetic seed concentrations and two flow rates supports the above model.  相似文献   

4.
李俊  方志财  齐鲁  胡立江 《生物磁学》2013,(26):5055-5058,5049
基于对生物磁学效应的研究,磁疗成为替代医学和补充医学的一种有效的治疗方法,本文通过对现有静磁场(恒定磁场)保健寝具磁标准和磁剂量的评述,首次提出磁保健寝具三围空间磁场的概念,指出采用磁感应强度在空间的强度分布作为磁保健剂量标准。论述了三围空间磁场具体磁参数的评价,包括所用磁源的表面磁感应强度,寝具织物表面磁场的穿透力、梯度、有效磁通量和空间能量等磁场分布的描述性指标。指出了静磁场保健寝具磁参数的合理的评价参量:为确保织物表面磁感应强度在目前认知的400~1100Gs有效安全剂量内,依据使用时的织物厚度,磁保健寝具选用的磁体表磁应在1000-3000Gs左右.且磁场的梯度不宜过大,磁场的平均穿透力在25-30cm左右,以确保空间磁场能量的有效作用于人体深处。  相似文献   

5.
We studied the swimming orientation of the ciliated protozoan Paramecium aurelia in a static magnetic field (0.78 T). P. aurelia is a complex of species termed syngens, whose cell morphology appears similar on microscopic examination. In the magnetic field, the cells of some syngens gradually changed their swimming orientation so that they were swimming perpendicular or parallel to the magnetic field, although such sensitivity to magnetic fields differs between syngens. When the temperature of the cell suspension was raised, the magnetic sensitivity of the cells was decreased. On the other hand, when the cells were cultured beforehand at a high temperature, their magnetic sensitivity was increased. These results raise the possibility that membrane lipid fluidity, which is inversely proportional to the membrane lipid order, contributes to the magnetic orientation of syngens. In this study, measurements of membrane lipid fluidity obtained using fluorescence image analysis with the lipophilic dye, laurdan (6-lauroyl-2-dimethylaminonaphtalene), showed that the degree of membrane lipid fluidity was correlated with the differences in magnetic orientation between syngens. That is, the syngens with decreased membrane fluidity showed an increased degree of magnetic orientation. Therefore, the membrane lipid order is a key factor in the magnetic orientation of Paramecium swimming.  相似文献   

6.
Single-molecule techniques make it possible to investigate the behavior of individual biological molecules in solution in real time. These techniques include so-called force spectroscopy approaches such as atomic force microscopy, optical tweezers, flow stretching, and magnetic tweezers. Amongst these approaches, magnetic tweezers have distinguished themselves by their ability to apply torque while maintaining a constant stretching force. Here, it is illustrated how such a “conventional” magnetic tweezers experimental configuration can, through a straightforward modification of its field configuration to minimize the magnitude of the transverse field, be adapted to measure the degree of twist in a biological molecule. The resulting configuration is termed the freely-orbiting magnetic tweezers. Additionally, it is shown how further modification of the field configuration can yield a transverse field with a magnitude intermediate between that of the “conventional” magnetic tweezers and the freely-orbiting magnetic tweezers, which makes it possible to directly measure the torque stored in a biological molecule. This configuration is termed the magnetic torque tweezers. The accompanying video explains in detail how the conversion of conventional magnetic tweezers into freely-orbiting magnetic tweezers and magnetic torque tweezers can be accomplished, and demonstrates the use of these techniques. These adaptations maintain all the strengths of conventional magnetic tweezers while greatly expanding the versatility of this powerful instrument.  相似文献   

7.
Magnetic responses of superparamagnetic nanoparticles to high-frequency AC magnetic fields with sufficiently large amplitudes are numerically simulated to exactly clarify the phenomena occurring in magnetic particle imaging. When the magnetic anisotropy energy inevitable in actual nanoparticles is taken into account in considering the magnetic potential, larger nanoparticles exhibit a delayed response to alternations of the magnetic fields. This kind of delay is rather remarkable in the lower-amplitude range of the field, where the assistance by the Zeeman energy to thermally activated magnetization reversal is insufficient. In some cases, a sign inversion of the third-order harmonic response was found to occur at some specific amplitude, despite the lack in DC bias magnetic field strength. Considering the attenuation of the AC magnetic field generated in the human body, it is possible that the phases of the signals from nanoparticles deep inside the body and those near the body surface are completely different. This may lead to artifacts in the reconstructed image. Furthermore, when the magnetic/thermal torque-driven rotation of the anisotropic nanoparticles as well as the magnetic anisotropy energy are taken into account, the simulated results show that, once the easy axes are aligned toward the direction of the DC bias magnetic field, it takes time to randomize them at the field-free point. During this relaxation, the third-order harmonic response depends highly upon the history of the magnetic field. This is because non-linearity of the anhysteretic magnetization curve for the superparamagnetic nanoparticles varies with the orientations of the easy axes. This history dependence may also lead to another artifact in magnetic particle imaging, when the scanning of the field-free point is faster than the Brownian relaxations.  相似文献   

8.
The influence of magnetic noise on the dynamics of magnetic nanoparticles under stochastic resonance conditions is considered. The effect of magnetic noise on the nanoparticles at a fixed actual ambient temperature is equivalent to an increase in the effective temperature of the thermostat. This observation may be used to test whether magnetic nanoparticles are involved in the biological effects of weak magnetic fields.  相似文献   

9.
A system for streptavidin detection using biotin conjugated to nano-sized bacterial magnetic particles (BMPs) has been developed. BMPs, isolated from magnetic bacteria, were used as magnetic markers for magnetic force microscopy (MFM) imaging. The magnetic signal was obtained from a single particle using MFM without application of an external magnetic field. The number of biotin conjugated BMPs (biotin-BMPs) bound to streptavidin immobilized on the glass slides increased with streptavidin concentrations up to 100 pg/ml. The minimum streptavidin detection limit using this technique is 1 pg/ml, which is 100 times more sensitive than a conventional fluorescent detection system. This is the first report using single domain nano-sized magnetic particles as magnetic markers for biosensing. This assay system can be used for immunoassay and DNA detection with high sensitivities.  相似文献   

10.
Magnetic fluid hyperthermia (MFH) therapy uses the magnetic component of electromagnetic fields in the radiofrequency spectrum to couple energy to magnetic nanoparticles inside tumors. In MFH therapy, magnetic fluid is injected into tumors and an alternating current (AC) magnetic flux is applied to heat the magnetic fluid- filled tumor. If the temperature can be maintained at the therapeutic threshold of 42°C for 30 minutes or more, the tumor cells can be destroyed. Analyzing the distribution of the magnetic fluid injected into tumors prior to the heating step in MFH therapy is an essential criterion for homogenous heating of tumors, since a decision can then be taken on the strength and localization of the applied external AC magnetic flux density needed to destroy the tumor without affecting healthy cells. This paper proposes a methodology for analyzing the distribution of magnetic fluid in a tumor by a specifically designed giant magnetoresistance (GMR) probe prior to MFH heat treatment. Experimental results analyzing the distribution of magnetic fluid suggest that different magnetic fluid weight densities could be estimated inside a single tumor by the GMR probe.  相似文献   

11.
磁性纳米颗粒具有独特的磁学性质,即在外加交变磁场下因产生磁滞释放热量,使其在生物医学领域,特别是肿瘤磁热疗,获得了广泛应用.到目前为止,磁性纳米颗粒介导的磁热疗成为一种治疗癌症的有效手段,已进入临床三期实验.因此,针对磁性纳米颗粒本身,优化设计尺寸、形貌、组分和表面修饰来提高其磁热性能,进而减小临床应用中的颗粒浓度来最小化毒副作用的研究,对肿瘤治疗及生物医药研究具有十分重要的意义.本综述详述如何优化调制磁性纳米颗粒以提高其磁热性能,为高效、低毒的磁性纳米颗粒的设计提供了指导性的研究方向.  相似文献   

12.
Candidatus Magnetoglobus multicellularis (CMm) is a multicellular organism in which each constituent cell is a magnetotactic bacterium. It has been observed that disaggregation of this organism provokes the death of the individual cells. The observed flagellar movement of the CMm indicates that the constituent cells move in a coordinated way, indicating a strong correlation between them and showing that this aggregate could be considered as an individual. As every constituent cell is a magnetotactic bacterium, every cell contributes with a magnetic moment vector to the resultant magnetic moment of the CMm organism that can be calculated through the vectorial sum of all the constituent magnetic moments. Scanning electron microscopy images of CMm organisms have shown that the constituent cells are distributed on a helix convoluted on a spherical surface. To analyze the magnetic properties of the distribution of magnetic moments on this curve, we calculated the magnetic energy numerically as well as the vectorial sum of the magnetic moment distribution as a function of the number of cells, the sphere radius and the number of spiral loops. This distribution proposes a magnetic organization not seen in any other living organism and shows that minimum energy configurations of magnetic moments are in spherical meridian chains, perpendicular to the helix turns. We observed that CMm has a high theoretical degree of magnetic optimization, showing that its geometrical structure is important to the magnetic response. Our results indicate that the helical structure must have magnetic significance.  相似文献   

13.
14.
The possibility is demonstrated of finding vacuum equilibrium magnetic configurations with an exactly pseudosymmetric nonparaxial boundary magnetic surface in the vicinity of which the pseudosymmetry condition is satisfied approximately. Equations are derived for calculating the boundary surface from a prescribed particular dependence of the magnetic field strength in special magnetic flux coordinates. In calculations, magnetic coordinates serve as ordinary angular coordinates, while their “magnetic” character is specified by additional integral conditions. As an example, a “tubular” orthogonal magnetic surface is calculated analytically.  相似文献   

15.
A new concept for the improvement of the downstream processing and purification is the so‐called magnetic separation. By using surface functionalized magnetic substrate particles, which selectively adsorb the target product, it can be directly separated out of a crude bioprocess stream. These methods are already used for analytical purposes, where only small amounts of functionalized particles are necessary. To apply the same concept at a larger scale, effective and economical procedures have to be provided. First, suitable process equipment has to be developed. Second, the magnetic particles have to be manufactured with a stable surface functionalization and long‐term stability for their reuse. Up to now mainly high‐gradient magnetic separation filter devices are applied for selective magnetic separation. They consist of a magnetic matrix in which the magnetic particles are trapped. In this work, a new magnetic filter is introduced that overcomes the capacity limitations of the current high‐gradient magnetic separation technology. The principle is demonstrated by selective recovery of lysozyme from hen egg white. Prior to the separation experiments magnetic beads with a strong acid cation‐exchange surface functionalization are synthesized. The separation procedure is implemented in only one unit operation. With the implementation of the displacement elution sequence lysozyme can be separated out of a hen egg white solution with a purification factor of PF=36 and a purity P=0.83.  相似文献   

16.
For developing a magnetic bioassay system, an investigation to determine the presence of a specific biomolecular interaction between biotin and streptavidin was done using magnetic nanoparticles and a silicon substrate with a self-assembled monolayer. Streptavidin was immobilized on the magnetic particles, and biotin was attached to the monolayer-modified substrate. The reaction of streptavidin-modified magnetic particles on the biotin-modified substrate was clearly observed under an optical microscope. The magnetic signals from the particles were detected using a magnetic force microscope. The results of this study demonstrate that the combination of a monolayer-modified substrate with biomolecule-modified magnetic particles is useful for detecting biomolecular interactions in medical and diagnostic analyses.  相似文献   

17.
目的:为解决目前床旁鼻肠管快速置入成功率低这一临床难题,该文提出一种基于磁驱动技术的空肠营养管的设计。方法:分析了现有空肠营养管置管过程中的动力因素,结合磁驱动技术原理,提出了通过体外旋转磁场带动体内感应磁体螺旋式前进的设计方案,以期缩短空肠营养管的飘管时间。结果:该设计包括磁性空肠营养管和体外磁力驱动装置两部分。其中磁性空肠营养管由管体和感应磁头两部分构成,感应磁头包括磁体内核和硅胶外壳。磁力驱动装置由多极磁体和手持式微型电机组成。操作时通过体外磁力驱动装置发出大旋转磁场带动空肠营养管的感应磁头做轴向旋转运动,可加速空肠营养管在肠道内的移动,达到缩短飘管时间的目的。结论:该设计基于磁驱动技术原理,设计巧妙,符合磁力学原理,操作简单,具有临床应用潜力。  相似文献   

18.
Single-valued conformal flux (magnetic) coordinates can always be introduced on arbitrary toroidal magnetic surfaces. It is shown how such coordinates can be obtained by transforming Boozer magnetic coordinates on the surfaces. The metrics is substantially simplified and the coordinate grid is orthogonalized at the expense of a more complicated representation of the magnetic field in conformal flux coordinates. This in turn makes it possible to introduce complex angular flux coordinates on any toroidal magnetic surface and to develop efficient methods for a complex analysis of the geometry of equilibrium magnetic surfaces. The complex analysis reveals how the plasma equilibrium problem is related to soliton theory. Magnetic surfaces of constant mean curvature are considered to exemplify this relationship.  相似文献   

19.
In the present study, the effect of the static and alternating magnetic field applied individually and in combination with an algal extract on the germination of soybean seeds (Glycine max (L.) Merrill) and chlorophyll content was examined. The exposure time of seeds to the static magnetic field was 3, 6, and 12 min, whereas to the alternating magnetic field was 1, 2.5, and 5 min. The static magnetic field was obtained by means of a permanent magnets system while the alternating magnetic field by means of magnetic coils. Algal extract was produced from a freshwater macroalga—Cladophora glomerata using ultrasound homogenizer. In the germination tests, 10% extract was applied to the paper substrate before sowing. This is the first study that compares the germination of soybean seeds exposed to the static and alternating magnetic field. The best effect on the germination and chlorophyll content in seedlings had synergistic action of the static magnetic field on seeds for 3 min applied together with the extract and alternating magnetic field used for 2.5 min. It is not possible to clearly state which magnetic field better stimulated the germination of seeds, but the chlorophyll content in seedlings was much higher for alternating magnetic field.  相似文献   

20.
The magnetic anisotropy of the whole radula, the major lateral radula teeth, and magnetic material in the major lateral radula teeth of the chiton Acanthochiton rubrolinestus LISCHKE have been studied by a magnetic torque meter and superconducting quantum interference device (SQUID) magnetometer. The length and width axes of the teeth are the easily magnetized axes, while the thickness axis is difficult to magnetize. The width and thickness axes of the radula are the easily magnetized axes, and the length axis is difficult to magnetize. The measurement results of the whole radula and the major lateral radula teeth agree well with each other. The magnetic anisotropy of the magnetic material is given as well as a possible distribution of the magnetic material in the major lateral radula teeth.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号