Background  

Active Magnetic Resonance Imaging implants are constructed as resonators tuned to the Larmor frequency of a magnetic resonance system with a specific field strength. The resonating circuit may be embedded into or added to the normal metallic implant structure. The resonators build inductively coupled wireless transmit and receive coils and can amplify the signal, normally decreased by eddy currents, inside metallic structures without affecting the rest of the spin ensemble. During magnetic resonance imaging the resonators generate heat, which is additional to the usual one described by the specific absorption rate. This induces temperature increases of the tissue around the circuit paths and inside the lumen of an active implant and may negatively influence patient safety.  相似文献   

2.
Lin IT  Yang HC  Chen JH 《PloS one》2012,7(4):e33207
High temperature superconducting (HTS) surface resonators have been used as a low loss RF receiver resonator for improving magnetic resonance imaging image quality. However, the application of HTS surface resonators is significantly limited by their filling factor. To maximize the filling factor, it is desirable to have the RF resonator wrapped around the sample so that more nuclear magnetic dipoles can contribute to the signal. In this study, a whole new Bi(2)Sr(2)Ca(2)Cu(2)O(3) (Bi-2223) superconducting saddle resonator (width of 5 cm and length of 8 cm) was designed for the magnetic resonance image of a mouse's whole body in Bruker 3 T MRI system. The experiment was conducted with a professionally-made copper saddle resonator and a Bi-2223 saddle resonator to show the difference. Signal-to-noise ratio (SNR) with the HTS saddle resonator at 77 K was 2.1 and 2 folds higher than that of the copper saddle resonator at 300 K for a phantom and an in-vivo mice whole body imaging. Testing results were in accordance with predicted ones, and the difference between the predicted SNR gains and measured SNR gains were 2.4%~2.7%. In summary, with this HTS saddle system, a mouse's whole body can be imaged in one scan and could reach a high SNR due to a 2 folds SNR gain over the professionally-made prototype of copper saddle resonator at 300 K. The use of HTS saddle resonator not only improves SNR but also enables a mouse's whole body screen in one scan.  相似文献   

3.
Thickness-shear mode (TSM) resonators have been used to characterize static rheological properties of plasma and whole blood samples. We demonstrated simple and rapid techniques for determining plasma viscosity without cell separation, for measuring erythrocyte sedimentation rate, and for tracking blood coagulation throughout the entire process. Additionally, mathematical models, previously developed to characterize surface-loaded resonators, were used to extract non-Newtonian and viscoelastic material properties of blood layers during sedimentation and coagulation experiments. These studies indicate the utility of the TSM resonator for several clinical applications. Because the resonators can be miniaturized, potential exists for extending the techniques for use inside the body or blood stream (in vivo).  相似文献   

4.

[Purpose]

To examine the effects of active drinking practices on fluid consumption and sweat rate while exercising in a hot environment.

[Methods]

Nine men completed two experiments. Each consisted of 3 phases: pre-testing (pre), training period, and post-testing (post). During testing, the subjects ran on a treadmill at a moderate intensity for 90 min at 39 ± 1℃ followed by a 3-h recovery. They drank ad libitum. During training, they ran for 90 min for 7 days while either drinking actively (AH, 150% of weight loss) or passively (PH, 50% of weight loss).

[Results]

The actual volume consumed in training was three times greater during AH than during PH. In post during AH, the volume of drinking was two times greater than pre (1592 ± 953 and 855 ± 551 mL, respectively; p < 0.05). No difference in volume consumption during PH between pre and post was found. The sweat loss during exercise was greater in post (1377 ± 956 mL) than in pre (558 ± 642 mL) during AH (p < 0.05), but not during PH. Rectal temperature and heart rate decreased after training. Serum osmolality following exercise were not different than the baseline or between the conditions.

[Conclusion]

Active drinking practices while exercising in a hot environment induced greater voluntary fluid intake and sweat loss.  相似文献   

5.

Background

Pennes Bio Heat Transfer Equation (PBHTE) has been widely used to approximate the overall temperature distribution in tissue using a perfusion parameter term in the equation during hyperthermia treatment. In the similar modeling, effective thermal conductivity (Keff) model uses thermal conductivity as a parameter to predict temperatures. However the equations do not describe the thermal contribution of blood vessels. A countercurrent vascular network model which represents a more fundamental approach to modeling temperatures in tissue than do the generally used approximate equations such as the Pennes BHTE or effective thermal conductivity equations was presented in 1996. This type of model is capable of calculating the blood temperature in vessels and describing a vasculature in the tissue regions.

Methods

In this paper, a countercurrent blood vessel network (CBVN) model for calculating tissue temperatures has been developed for studying hyperthermia cancer treatment. We use a systematic approach to reveal the impact of a vasculature of blood vessels against a single vessel which most studies have presented. A vasculature illustrates branching vessels at the periphery of the tumor volume. The general trends present in this vascular model are similar to those shown for physiological systems in Green and Whitmore. The 3-D temperature distributions are obtained by solving the conduction equation in the tissue and the convective energy equation with specified Nusselt number in the vessels.

Results

This paper investigates effects of size of blood vessels in the CBVN model on total absorbed power in the treated region and blood flow rates (or perfusion rate) in the CBVN on temperature distributions during hyperthermia cancer treatment. Also, the same optimized power distribution during hyperthermia treatment is used to illustrate the differences between PBHTE and CBVN models. Keff (effective thermal conductivity model) delivers the same difference as compared to the CBVN model. The optimization used here is adjusting power based on the local temperature in the treated region in an attempt to reach the ideal therapeutic temperature of 43°C. The scheme can be used (or adapted) in a non-invasive power supply application such as high-intensity focused ultrasound (HIFU). Results show that, for low perfusion rates in CBVN model vessels, impacts on tissue temperature becomes insignificant. Uniform temperature in the treated region is obtained.

Conclusion

Therefore, any method that could decrease or prevent blood flow rates into the tumorous region is recommended as a pre-process to hyperthermia cancer treatment. Second, the size of vessels in vasculatures does not significantly affect on total power consumption during hyperthermia therapy when the total blood flow rate is constant. It is about 0.8% decreasing in total optimized absorbed power in the heated region as γ (the ratio of diameters of successive vessel generations) increases from 0.6 to 0.7, or from 0.7 to 0.8, or from 0.8 to 0.9. Last, in hyperthermia treatments, when the heated region consists of thermally significant vessels, much of absorbed power is required to heat the region and (provided that finer spatial power deposition exists) to heat vessels which could lead to higher blood temperatures than tissue temperatures when modeled them using PBHTE.  相似文献   

6.

Objective

To develop abdominal magnetic resonance imaging (MRI) protocol to measure pancreatic volume in humans and to validate it in large animals.

Materials and Methods

We performed abdominal MRI in eight mini-pigs using a clinical 3T MRI system. We used consecutive parallel abdominal slices, covering the entire pancreas to calculate pancreatic volume. Following MRI, animals were sacrificed, the pancreas was removed, and the volume of the pancreas was measured by water displacement. We used the same MRI protocol to measure pancreatic volume in 21 humans. To assess reproducibility of in vivo measurement we repeated MRI pancreas volume evaluation within 24 hours in additional five humans.

Results

In mini-pigs the measurements of pancreatic volume by MRI and by water displacement were almost identical (R2 = 0.9867; p<0.0001). In humans the average pancreas volume was 72.7+/−4.5 ml, range from 35.0 to 105.5 ml. This result is in strong agreement with results of previous large postmortem and computed tomography (CT) studies. Repeated measurements of pancreatic volume in humans were highly reproducible. Pancreatic volume measured in vivo was negatively correlated with age, body fat mass, pancreatic TG levels, and visceral fat mass.

Conclusions

These initial results are highly encouraging and our protocol for pancreatic volume estimation in vivo may prove useful in obesity research to follow in vivo changes of pancreatic volume and structure during time course of obesity and type 2 diabetes development.  相似文献   

7.
IT Lin  HC Yang  JH Chen 《PloS one》2012,7(8):e42509
This study examines the enlargement of the field of view (FOV) and the maintenance of a high signal-to-noise ratio (SNR) through the use of two high-temperature superconducting (HTS) resonators in a 3T MRI. Two Bi(2)Sr(2)Ca(2)Cu(3)O(x) (Bi-2223) surface resonators, each of 4-cm diameter, were used in a 3T MRI. Professionally made copper resonators operate at 300 K, but each Bi-2223 resonator, operated at 77 K and demonstrated a 3.75 fold increase in SNR gain. For the same scanning time, the SNR of the images of a rat's brain and back, obtained using two small Bi-2223 surface resonators, was higher than that obtained using a single 8-cm surface resonator.  相似文献   

8.
Non-invasive and rapid determination of plant biomass would be beneficial for a number of research aims. Here, we present a novel device to non-invasively determine plant water content as a proxy for plant biomass. It is based on changes of dielectric properties inside a microwave cavity resonator induced by inserted plant material. The water content of inserted shoots leads to a discrete shift in the centre frequency of the resonator. Calibration measurements with pure water showed good spatial homogeneity in the detection volume of the microwave resonators and clear correlations between water content and centre frequency shift. For cut tomato and tobacco shoots, linear correlations between fresh weight and centre frequency shift were established. These correlations were used to continuously monitor diel growth patterns of intact plants and to determine biomass increase over several days. Interferences from soil and root water were excluded by shielding pots with copper. The presented proof of principle shows that microwave resonators are promising tools to quantitatively detect the water content of plants and to determine plant biomass. As the method is non-invasive, integrative and fast, it provides the opportunity for detailed, dynamic analyses of plant growth, water status and phenotype.  相似文献   

9.

Background

Hot spot residues are functional sites in protein interaction interfaces. The identification of hot spot residues is time-consuming and laborious using experimental methods. In order to address the issue, many computational methods have been developed to predict hot spot residues. Moreover, most prediction methods are based on structural features, sequence characteristics, and/or other protein features.

Results

This paper proposed an ensemble learning method to predict hot spot residues that only uses sequence features and the relative accessible surface area of amino acid sequences. In this work, a novel feature selection technique was developed, an auto-correlation function combined with a sliding window technique was applied to obtain the characteristics of amino acid residues in protein sequence, and an ensemble classifier with SVM and KNN base classifiers was built to achieve the best classification performance.

Conclusion

The experimental results showed that our model yields the highest F1 score of 0.92 and an MCC value of 0.87 on ASEdb dataset. Compared with other machine learning methods, our model achieves a big improvement in hot spot prediction.
  相似文献   

10.

Aim

The study aimed to determine a prognostic value of primary tumor volume measured on the basis of integrated positron emission tomography–computerized tomography (PET–CT) in terms of mediastinal nodal metastases (N2) prediction in non-small-cell lung cancer (NSCLC) patients with PET–CT N2 negative lymph nodes.

Methods

The records of 70 potentially operable NSCLC patients treated with surgical resection were analyzed. All patients underwent diagnostic, preoperative PET–CT, which was the basis for tumor volume calculations as well as the evaluation of N2 nodes status. The logistic regression analysis was employed to determine correlation between mediastinal nodal involvement and volume of primary tumor (izoSUV2.5 volume), that is the volume of primary tumor inside SUV 2.5 line, tumor histology, location (peripheral vs. central), hilar node status.

Results

A statistically significant correlation between mediastinal node involvement and izoSUV2.5 volume, tumor histology, locations peripheral vs. central and hilar node status was found. The risk of mediastinal lymph node metastasis is 24% for tumor volume of 100 cm3 and increases up to 40% for tumor volume of 360 cm3. An increase of tumor volume by 1 cm3 increases the risk of lymph node disease by 0.3%. Tumor histology adenocarcinoma vs. squamous cell carcinoma increases the risk of mediastinal lymph node involvement by 195%, location central vs. peripheral by 68% and hilar node involvement by 166%.

Conclusions

The study demonstrates that izoSUV2.5 volume of primary tumor may be considered as a prognostic factor in NSCLC patients, since it strongly correlates with mediastinal lymph node pathological status. This correlation is modified by primary tumor location, histology and hilar node involvement.  相似文献   

11.
IntroductionRecent advances have enabled fast magnetic resonance imaging (MRI) of solid materials. This development has opened up new applications for MRI, but, at the same time, uncovered new challenges. Previously, MRI-invisible materials like the housing of MRI detection coils are now readily depicted and either cause artifacts or lead to a decreased image resolution. In this contribution, we present versatile, multi-nuclear single and dual-tune MRI coils that stand out by (1) a low hydrogen content for high-resolution MRI of dry solids without artifacts; (2) a modular approach with exchangeable inductors of variable volumes to optimally enclose the given object; (3) low cost and low manufacturing effort that is associated with the modular approach; (4) accurate sample placement in the coil outside of the bore, and (5) a wide, single- or dual-tune frequency range that covers several nuclei and enables multinuclear MRI without moving the sample.

Materials and Methods

The inductors of the coils were constructed from self-supporting copper sheets to avoid all plastic materials within or around the resonator. The components that were mounted at a distance from the inductor, including the circuit board, coaxial cable and holder were manufactured from polytetrafluoroethylene.

Results and Conclusion

Residual hydrogen signal was sufficiently well suppressed to allow 1H-MRI of dry solids with a minimum field of view that was smaller than the sensitive volume of the coil. The SNR was found to be comparable but somewhat lower with respect to commercial, proton-rich quadrature coils, and higher with respect to a linearly-polarized commercial coil. The potential of the setup presented was exemplified by 1H / 23Na high-resolution zero echo time (ZTE) MRI of a model solution and a dried human molar at 9.4 T. A full 3D image dataset of the tooth was obtained, rich in contrast and similar to the resolution of standard cone-beam computed tomography.  相似文献   

12.

OBJECTIVES

This study evaluates the repeatability of brain perfusion using dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) with a variety of post-processing methods.

METHODS

Thirty-two patients with newly diagnosed glioblastoma were recruited. On a 3-T MRI using a dual-echo, gradient-echo spin-echo DSC-MRI protocol, the patients were scanned twice 1 to 5 days apart. Perfusion maps including cerebral blood volume (CBV) and cerebral blood flow (CBF) were generated using two contrast agent leakage correction methods, along with testing normalization to reference tissue, and application of arterial input function (AIF). Repeatability of CBV and CBF within tumor regions and healthy tissues, identified by structural images, was assessed with intra-class correlation coefficients (ICCs) and repeatability coefficients (RCs). Coefficients of variation (CVs) were reported for selected methods.

RESULTS

CBV and CBF were highly repeatable within tumor with ICC values up to 0.97. However, both CBV and CBF showed lower ICCs for healthy cortical tissues (up to 0.83), healthy gray matter (up to 0.95), and healthy white matter (WM; up to 0.93). The values of CV ranged from 6% to 10% in tumor and 3% to 11% in healthy tissues. The values of RC relative to the mean value of measurement within healthy WM ranged from 22% to 42% in tumor and 7% to 43% in healthy tissues. These percentages show how much variation in perfusion parameter, relative to that in healthy WM, we expect to observe to consider it statistically significant. We also found that normalization improved repeatability, but AIF deconvolution did not.

CONCLUSIONS

DSC-MRI is highly repeatable in high-grade glioma patients.  相似文献   

13.

Background

The ability to measure 25-hydroxyvitamin D (25OHD) levels from blood spot cards can simplify sample collection versus samples obtained by venipuncture, particularly in populations in whom it is difficult to draw blood. We sought to validate the use of blood spot samples for the measurement of 25OHD compared to serum or whole blood samples and correlate the measured levels with intake estimated from dietary recall.

Methods

Utilizing 109 biological mothers of infants enrolled in the Tennessee Children''s Respiratory Initiative cohort, we measured 25OHD levels through highly selective liquid chromatography–tandem mass spectrometry on samples from blood spot cards, serum, and whole blood collected at enrollment. Dietary questionnaires (n = 65) were used to assess 25OHD intake by dietary recall. Sample collection measures were assessed for agreement and 25OHD levels for association with dietary 25OHD intake.

Results

The mean absolute differences (95%CI) in 25OHD levels measured between whole blood and blood spot (n = 50 pairs) or serum and blood spot (n = 20) were 3.2 (95%CI:1.6, 4.8) ng/ml and 1.5 (95%CI:−0.5,3.4) ng/mL. Intake by dietary recall was marginally associated with 25OHD levels after adjustment for current smoking and race in linear regression.

Discussion

25OHD levels determined by mass spectrometry from blood spot cards, serum and whole blood show relatively good agreement, although 25OHD levels are slightly lower when measured by blood spot cards. Blood spot samples are a less invasive means of obtaining 25OHD measurements, particularly in large population-based samples, or among children when venipuncture may decrease study participation.  相似文献   

14.

Background  

It is well known that most of the binding free energy of protein interaction is contributed by a few key hot spot residues. These residues are crucial for understanding the function of proteins and studying their interactions. Experimental hot spots detection methods such as alanine scanning mutagenesis are not applicable on a large scale since they are time consuming and expensive. Therefore, reliable and efficient computational methods for identifying hot spots are greatly desired and urgently required.  相似文献   

15.

Background

It is well known that hypoxic exercise in healthy individuals increases limb blood flow, leg oxygen extraction and limb vascular conductance during knee extension exercise. However, the effect of hypoxia on cardiac output, and total vascular conductance is less clear. Furthermore, the oxygen delivery response to hypoxic exercise in well trained individuals is not well known. Therefore our aim was to determine the cardiac output (Doppler echocardiography), vascular conductance, limb blood flow (Doppler echocardiography) and muscle oxygenation response during hypoxic knee extension in normally active and endurance-trained males.

Methods

Ten normally active and nine endurance-trained males (VO2max = 46.1 and 65.5 mL/kg/min, respectively) performed 2 leg knee extension at 25, 50, 75 and 100% of their maximum intensity in both normoxic and hypoxic conditions (FIO2 = 15%; randomized order). Results were analyzed with a 2-way mixed model ANOVA (group × intensity).

Results

The main finding was that in normally active individuals hypoxic sub-maximal exercise (25 – 75% of maximum intensity) brought about a 3 fold increase in limb blood flow but decreased stroke volume compared to normoxia. In the trained group there were no significant changes in stroke volume, cardiac output and limb blood flow at sub-maximal intensities (compared to normoxia). During maximal intensity hypoxic exercise limb blood flow increased approximately 300 mL/min compared to maximal intensity normoxic exercise.

Conclusion

Cardiorespiratory fitness likely influences the oxygen delivery response to hypoxic exercise both at a systemic and limb level. The increase in limb blood flow during maximal exercise in hypoxia (both active and trained individuals) suggests a hypoxic stimulus that is not present in normoxic conditions.
  相似文献   

16.

Purpose

To evaluate changes in nucleus pulposus volume as a potential parameter for the effects of disc decompression.

Methods

Fifty-two discs (T8 to L1) were extracted from 26 pigs and separated into thoracic (T8 to T11) and thoracolumbar discs (T12 to L1). The discs were imaged using 7.1 Tesla ultrahigh-field magnetic resonance imaging (MRI) with acquisition of axial T2-weighted turbo spin-echo sequences for determination of baseline and postinterventional nucleus pulposus volumes. Volumes were calculated using OsiriX® (http://www.osirix-viewer.com). After randomization, one group was treated with nucleoplasty, while the placebo group was treated with an identical procedure but without coblation current. The readers analyzing the MR images were blinded to the kind of procedure performed. Baseline and postinterventional volumes were compared between the nucleoplasty and placebo group.

Results

Average preinterventional nucleus volume was 0.799 (SD: 0.212) ml. Postinterventional volume reduction in the nucleoplasty group was significant at 0.052 (SD: 0.035) ml or 6.30% (p<0.0001) (thoracic discs) and 0.082 (SD: 0.042) ml or 7.25% (p = 0.0078) (thoracolumbar discs). Nucleoplasty achieved volume reductions of 0.114 (SD: 0.054) ml or 14.72% (thoracic) and 0.093 (SD: 0.081) ml or 11.61% (thoracolumbar) compared with the placebo group.

Conclusions

Nucleoplasty significantly reduces thoracic and thoracolumbar nucleus pulposus volumes in porcine discs.  相似文献   

17.

Background

Febrile malaria is the most common clinical manifestation of P. falciparum infection, and is often the primary endpoint in clinical trials and epidemiological studies. Subjective and objective fevers are both used to define the endpoint, but have not been carefully compared, and the relative incidence of clinical malaria by active and passive case detection is unknown.

Methods

We analyzed data from cohorts under active and passive surveillance, including 19,462 presentations with fever and 5,551 blood tests for asymptomatic parasitaemia. A logistic regression model was used to calculate Malaria Attributable Fractions (MAFs) for various case definitions. Incidences of febrile malaria by active and passive surveillance were compared in a subset of children matched for age and location.

Results

Active surveillance identified three times the incidence of clinical malaria as passive surveillance in a subset of children matched for age and location. Objective fever (temperature≥37.5°C) gave consistently higher MAFs than case definitions based on subjective fever.

Conclusion

The endpoints from active and passive surveillance have high specificity, but the incidence of endpoints is lower on passive surveillance. Subjective fever had low specificity and should not be used in primary endpoint. Passive surveillance will reduce the power of clinical trials but may cost-effectively deliver acceptable sensitivity in studies of large populations.  相似文献   

18.
By solving a nonlinear equation for a heat source with a power proportional to Т β (β > 1), it is shown that heat localization in the transverse cross section of a magnetic tube with a classical thermal conductivity occurs in the blowup regime in the form of microstructures—temperature background cells bounded by hot walls with a spatial scale of <100 m. The reduction in the integral X-ray emissivity observed on board of spacecrafts in the early stage of the flare is attributed to thermal self-focusing, i.e., a decrease in the factor of filling of the flare volume with hot plasma due to the narrowing of the hot walls of the microstructure.  相似文献   

19.

Background  

A protein binding hot spot is a small cluster of residues tightly packed at the center of the interface between two interacting proteins. Though a hot spot constitutes a small fraction of the interface, it is vital to the stability of protein complexes. Recently, there are a series of hypotheses proposed to characterize binding hot spots, including the pioneering O-ring theory, the insightful 'coupling' and 'hot region' principle, and our 'double water exclusion' (DWE) hypothesis. As the perspective changes from the O-ring theory to the DWE hypothesis, we examine the physicochemical properties of the binding hot spots under the new hypothesis and compare with those under the O-ring theory.  相似文献   

20.

Background

The aim of this study was to evaluate whether arterial spin labeling (ASL) perfusion magnetic resonance imaging (MRI) can reliably quantify perfusion deficit as compared to dynamic susceptibility contrast (DSC) perfusion MRI.

Methods

Thirty-nine patients with acute ischemic stroke in the anterior circulation territory were recruited. All underwent ASL and DSC MRI perfusion scans within 30 hours after stroke onset and 31 patients underwent follow-up MRI scans. ASL cerebral blood flow (CBF) and DSC time to maximum (Tmax) maps were used to calculate the perfusion defects. The ASL CBF lesion volume was compared to the DSC Tmax lesion volume by Pearson''s correlation coefficient and likewise the ASL CBF and DSC Tmax lesion volumes were compared to the final infarct sizes respectively. A repeated measures analysis of variance and least significant difference post hoc test was used to compare the mean lesion volumes among ASL CBF, DSC Tmax >4–6 s and final infarct.

Results

Mean patient age was 72.6 years. The average time from stroke onset to MRI was 13.9 hours. The ASL lesion volume showed significant correlation with the DSC lesion volume for Tmax >4, 5 and 6 s (r = 0.81, 0.82 and 0.80; p<0.001). However, the mean lesion volume of ASL (50.1 ml) was significantly larger than those for Tmax >5 s (29.2 ml, p<0.01) and Tmax >6 s (21.8 ml, p<0.001), while the mean lesion volumes for Tmax >5 or 6 s were close to mean final infarct size.

Conclusion

Quantitative measurement of ASL perfusion is well correlated with DSC perfusion. However, ASL perfusion may overestimate the perfusion defects and therefore further refinement of the true penumbra threshold and improved ASL technique are necessary before applying ASL in therapeutic trials.  相似文献   