首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Our objective was to compare three methods (enzyme-linked immunosorbent assay [ELISA], endpoint and quantitative polymerase chain reaction [E-PCR and Q-PCR]) for detection and quantitation of Bacteroides forsythus in 56 plaque samples from seven subjects with progressive periodontal disease. Samples collected in buffer were pelleted and resuspended in 500 microl of water. Fifty microl aliquots were removed for an ELISA performed on bacteria or plaque immobilized on 96-well plates and probed with B. forsythus specific antibody. An occurrence of 3.7+/-0.6 x 10(4) or more bacteria were detected by ELISA in pure culture; 26 of 54 plaque samples were positive, two samples could not be analyzed. Samples for PCR were autoclaved for 10 min prior to use. The detection level of E-PCR using primers specific for B. forsythus 16S rRNA was 200 cells and 42 out of 56 samples were positive based on ethidium bromide stained agarose gels. Q-PCR using the same primers combined with a nested fluorescent oligonucleotide probe detected 10+/-0.32 bacteria in pure culture; 43 of 56 plaque samples were positive. The ELISA and Q-PCR obtained identical results with 36 of the 54 samples assayed; there were one false positive and 17 false negative ELISA results using Q-PCR as standard. The positive proportions of plaque samples were almost the same for E-PCR and Q-PCR. We conclude that the PCR methods are more appropriate for a multicenter study because of greater sensitivity and convenience of sample transportation from clinics to a central laboratory.  相似文献   

2.
目的:建立人博卡病毒(HBoV)核酸特异、快速、敏感的TaqMan探针实时定量PCR检测方法,并对临床样本进行检测。方法:比对编码HBoV非结构蛋白NP-1的基因序列,选取其保守片段设计引物和探针,建立实时荧光定量PCR检测方法,并与传统PCR方法进行比较,然后分别对两者的灵敏性、特异性、稳定性及临床样本检验的适用性等进行评价。结果:所建立的实时定量PCR检测方法可用于HBoV的特异性检测;相对于传统PCR所达到的250拷贝/反应的检测灵敏度,实时定量PCR的检测灵敏度可高达10拷贝/反应,检测范围为109~101拷贝/反应,且具有良好的特异性和重复性;初步用于76份临床呼吸道标本检测,检出阳性5例,高于普通PCR方法(3/76)。结论:建立了HBoV TaqMan探针实时定量PCR检测方法,并可用于临床鼻咽拭子样本的检测,为开展HBoV流行病学监测及早期临床诊断提供了技术手段。  相似文献   

3.
We describe a novel quantitative real-time (Q)-PCR assay for Listeria monocytogenes based on the coamplification of a target hly gene fragment and an internal amplification control (IAC). The IAC is a chimeric double-stranded DNA containing a fragment of the rapeseed BnACCg8 gene flanked by the hly-specific target sequences. This IAC is detected using a second TaqMan probe labeled with a different fluorophore, enabling the simultaneous monitoring of the hly and IAC signals. The hly-IAC assay had a specificity and sensitivity of 100%, as assessed using 49 L. monocytogenes isolates of different serotypes and 96 strains of nontarget bacteria, including 51 Listeria isolates. The detection and quantification limits were 8 and 30 genome equivalents, and the coefficients for PCR linearity (R2) and efficiency (E) were 0.997 and 0.80, respectively. We tested the performance of the hly-IAC Q-PCR assay using various broth media and food matrices. Fraser and half-Fraser media, raw pork, and raw or cold-smoked salmon were strongly PCR-inhibitory. This Q-PCR assay for L. monocytogenes, the first incorporating an IAC to be described for quantitative detection of a food-borne pathogen, is a simple and robust tool facilitating the identification of false negatives or underestimations of contamination loads due to PCR failure.  相似文献   

4.
Quantitative real-time PCR (qPCR) commonly uses the fluorogenic 5′ nuclease (TaqMan) and SYBR Green I (SG) detection chemistries to enumerate biomarker genes. Dehalococcoides (Dhc) are keystone bacteria for the detoxification of chlorinated ethenes, and the Dhc 16S ribosomal RNA (rRNA) gene serves as a biomarker for monitoring reductive dechlorination in contaminated aquifers. qPCR enumeration of Dhc biomarker genes using the TaqMan or SG approach with the same primer set yielded linear calibration curves over a seven orders of magnitude range with similar amplification efficiencies. The TaqMan assay discriminates specific from nonspecific amplification observed at low template concentrations with the SG assay, and had a 10-fold lower limit of detection of ~3 copies per assay. When applied to Dhc pure cultures and Dhc-containing consortia, both detection methods enumerated Dhc biomarker genes with differences not exceeding 3-fold. Greater variability was observed with groundwater samples, and the SG chemistry produced false-positive results or yielded up to 6-fold higher biomarker gene abundances compared to the TaqMan method. In most cases, the apparent error associated with SG detection resulted from quantification of nonspecific amplification products and was more pronounced with groundwater samples that had low biomarker concentrations or contained PCR inhibitors. Correction of the apparent error using post-amplification melting curve analysis produced 2 to 21-fold lower abundance estimates; however, gel electrophoretic analysis of amplicons demonstrated that melting curve analysis was insufficient to recognize all nonspecific amplification. Upon exclusion of nonspecific amplification products identified by combined melting curve and electrophoretic amplicon analyses, the SG method produced false-negative results compared to the TaqMan method. To achieve sensitive and accurate quantification of Dhc biomarker genes in environmental samples (e.g., groundwater) and avoid erroneous conclusions, the analysis should rely on TaqMan detection chemistry, unless additional analyses validate the results obtained with the SG approach.  相似文献   

5.
应用TaqMan荧光定量PCR检测土拉弗朗西斯菌   总被引:2,自引:0,他引:2  
目的:利用Roche LightCycler实时定量PCR系统建立一种快速、灵敏、特异的检测土拉弗朗西斯菌的方法。方法:基于TaqMan荧光探针实时定量PCR技术,选择土拉弗朗西斯菌染色体上的特异序列[醇醛酮还原酶(AKR)和外膜蛋白FopA基因]作为检测靶序列,建立土拉弗朗西斯菌实时定量PCR检测方法;评价该检测方法的特异性和灵敏性;采用克隆菌株污染环境土壤来模拟实际样品,评价该检测方法在快速检测与现场检测等实际应用中的表现。结果:优化筛选基因组中的FT-AKR和FT-fopA片段作为检测靶序列,所建立的土拉弗朗西斯菌实时定量PCR检测方法检测克隆菌株质粒的灵敏度均为10个拷贝/每个反应体系;以其他非土拉弗朗西斯菌为模板未出现非特异扩增;模拟环境土壤样品检测灵敏度2个引物对分别为440和960CFU/g土壤;盲测实验结果显示对于灵敏度范围内的阳性样本均能正确识别,并能正确检测出不同浓度的阳性样本。以FT-fopA片段为靶序列的扩增效率不及基于FT-AKR引物对的扩增。结论:基于FT-AKR片段的引物对扩增效率高,检测土拉弗朗西斯菌具有特异、灵敏的特点,对临床诊断、环境污染监测、防治生物突发事件等具有重要意义。  相似文献   

6.
Leptospirosis, caused by pathogenic Leptospira, is one of the most important zoonoses in the world. Several molecular techniques have been developed for detection and differentiation between pathogenic and saprophytic Leptospira spp. The aim of this study was to develop a rapid and simple assay for specific detection and differentiation of pathogenic Leptospira spp. by multiplex real-time PCR (TaqMan) assay using primers and probes targeting Leptospira genus specific 16S ribosomal RNA gene, the pathogen specific lig A/B genes and nonpathogen Leptospira biflexa specific 23S ribosomal RNA gene. Sixteen reference strains of Leptospira spp. including pathogenic and nonpathogenic and ten other negative control bacterial strains were used in the study. While the 16S primers amplified target from both pathogenic and non-pathogenic leptospires, the ligA/B and the 23S primers amplified target DNA from pathogenic and non-pathogenic leptospires, respectively. The multiplex real-time PCR (TaqMan) assay detection limit, that is, the sensitivity was found approximately 1 x 10(2) cells/ml for ligA/B gene and 23S ribosomal RNA gene, and 10 cells/ml 16S ribosomal RNA. The reaction efficiencies were 83-105% with decision coefficients of more than 0.99 in all multiplex assays. The multiplex real-time PCR (TaqMan) assay yielded negative results with the ten other control bacteria. In conclusion, the developed multiplex real-time PCR (TaqMan) assay is highly useful for early diagnosis and differentiation between pathogenic and non-pathogenic leptospires in a reaction tube as having high sensitivity and specificity.  相似文献   

7.
The current methods for the detection of pathogenic Yersinia enterocolitica bacteria in food are time consuming and inefficient. Therefore, we have developed and evaluated in-house a TaqMan probe-based real-time PCR method for the detection of this pathogen. The complete method comprises overnight enrichment, DNA extraction, and real-time PCR amplification. Also included in the method is an internal amplification control. The selected primer-probe set was designed to use a 163-bp amplicon from the chromosomally located gene ail (attachment and invasion locus). The selectivity of the PCR method was tested with a diverse range (n = 152) of related and unrelated strains, and no false-negative or false-positive PCR results were obtained. The sensitivity of the PCR amplification was 85 fg purified genomic DNA, equivalent to 10 cells per PCR tube. Following the enrichment of 10 g of various food samples (milk, minced beef, cold-smoked sausage, fish, and carrots), the sensitivity ranged from 0.5 to 55 CFU Y. enterocolitica. Good precision, robustness, and efficiency of the PCR amplification were also established. In addition, the method was tested on naturally contaminated food; in all, 18 out of 125 samples were positive for the ail gene. Since no conventional culture method could be used as a reference method, the PCR products amplified from these samples were positively verified by using conventional PCR and sequencing of the amplicons. A rapid and specific real-time PCR method for the detection of pathogenic Y. enterocolitica bacteria in food, as presented here, provides a superior alternative to the currently available detection methods and makes it possible to identify the foods at risk for Y. enterocolitica contamination.  相似文献   

8.
An enhanced polymerase chain reaction (PCR) assay to detect the coronavirus associated with severe acute respiratory syndrome (SARS-CoV) was developed in which a target gene pre-amplification step preceded TaqMan real-time fluorescent PCR. Clinical samples were collected from 120 patients diagnosed as suspected or probable SARS cases and analyzed by conventional PCR followed by agarose gel electrophoresis, conventional TaqMan real-time PCR, and our enhanced TaqMan real-time PCR assays. An amplicon of the size expected from SARS-CoV was obtained from 28/120 samples using the enhanced real-time PCR method. Conventional PCR and real-time PCR alone identified fewer SARS-CoV positive cases. Results were confirmed by viral culture in 3/28 cases. The limit of detection of the enhanced real-time PCR method was 10(2)-fold higher than the standard real-time PCR assay and 10(7)-fold higher than conventional PCR methods. The increased sensitivity of the assay may help control the spread of the disease during future SARS outbreaks.  相似文献   

9.
We have developed a rapid procedure for the detection of virulent Yersinia enterocolitica in ground pork by combining a previously described PCR with fluorescent dye technologies. The detection method, known as the fluorogenic 5' nuclease assay (TaqMan), produces results by measuring the fluorescence produced during PCR amplification, requiring no post-PCR processing. The specificity of the chromosomal yst gene-based assay was tested with 28 bacterial isolates that included 7 pathogenic and 7 nonpathogenic serotypes of Y. enterocolitica, other species of Yersinia (Y. aldovae, Y. pseudotuberculosis, Y. mollaretti, Y. intermedia, Y. bercovieri, Y. ruckeri, Y. frederiksenii, and Y. kristensenii), and other enteric bacteria (Escherichia, Salmonella, Citrobacter, and Flavobacterium). The assay was 100% specific in identifying the pathogenic strains of Y. enterocolitica. The sensitivity of the assay was found to be >/=10(2) CFU/ml in pure cultures and >/=10(3) CFU/g in spiked ground pork samples. Results of the assay with food enrichments prespiked with Y. enterocolitica serotypes O:3 and O:9 were comparable to standard culture results. Of the 100 field samples (ground pork) tested, 35 were positive for virulent Y. enterocolitica with both 5' nuclease assay and conventional virulence tests. After overnight enrichment the entire assay, including DNA extraction, amplification, and detection, could be completed within 5 h.  相似文献   

10.
11.
A sensitive and quantitative TaqMan assay for the causative agent of chytridiomycosis in amphibians (Batrachochytrium dendrobatidis) has been developed and is routinely used in diagnostic laboratories. We assessed whether the real time detection of the TaqMan assay was as sensitive as the detection of the PCR product by agarose gel electrophoresis and ethidium bromide staining. We found, for practical purposes, that gel-based detection of the diagnostic fragment produced by means of the TaqMan assay or by conventional PCR that used a different polymerase and reaction mix was as sensitive as the real-time detection of the TaqMan assay. We recommend the qualified use of conventional PCR amplification combined with agarose gel electrophoresis and ethidium bromide staining for studies where only prevalence data are required, funding for equipment is limited or the acquisition of a real-time system is not cost effective.  相似文献   

12.
Efficient methods for constructing 16S tag amplicon libraries for pyrosequencing are needed for the rapid and thorough screening of infectious bacterial diversity from host tissue samples. Here we have developed a double‐nested PCR methodology that generates 16S tag amplicon libraries from very small amounts of bacteria/host samples. This methodology was tested for 133 kidney samples from the lake whitefish Coregonus clupeaformis (Salmonidae) sampled in five different lake populations. The double‐nested PCR efficiency was compared with two other PCR strategies: single primer pair amplification and simple nested PCR. The double‐nested PCR was the only amplification strategy to provide highly specific amplification of bacterial DNA. The resulting 16S amplicon libraries were synthesized and pyrosequenced using 454 FLX technology to analyse the variation of pathogenic bacteria abundance. The proportion of the community sequenced was very high (Good’s coverage estimator; mean = 95.4%). Furthermore, there were no significant differences of sequence coverage among samples. Finally, the occurrence of chimeric amplicons was very low. Therefore, the double‐nested PCR approach provides a rapid, informative and cost‐effective method for screening fish immunobiomes and most likely applicable to other low‐density microbiomes as well.  相似文献   

13.
目的:建立针对O1群霍乱弧菌的实时荧光定量TaqMan PCR快速检测方法,并进行模拟粪便标本的检测评价。方法:根据O1群霍乱弧菌O抗原编码基因rfb的特异性序列设计引物和TaqMan探针,建立检测O1群霍乱弧菌的实时荧光定量TaqMan PCR快速检测方法,对所建立的方法分别进行实验室内的灵敏度及特异性评价;将O1群霍乱弧菌灭活菌株悬液倍比稀释后与健康成人新鲜粪便混匀,制备成模拟带菌者粪便标本,提取DNA,进行Taq-Man PCR检测,用以评价该方法。结果:建立了快速检测O1群霍乱弧菌的实时荧光定量TaqMan PCR方法,灵敏度为每反应体系104拷贝;该方法对其他14种肠道菌DNA没有扩增;该方法对模拟粪便标本的检测灵敏度为每反应体系102 CFU。结论:建立了一种快速、高效检测O1群霍乱弧菌的荧光定量PCR检测方法,该方法可用于O1群霍乱弧菌临床粪便标本的检测。  相似文献   

14.
A disposable horseradish peroxidase (HRP)-based electrochemical genosensor was developed for chronoamperometric detection of single-stranded asymmetric lolB gene PCR amplicon (118 bp in length) of the food-borne pathogen, Vibrio cholerae. A two-step sandwich-type hybridization strategy using two specific probes was employed for specific detection of the target single-stranded DNA (ssDNA). The analytical performances of the detection platform have been evaluated using a synthetic ssDNA (ST3) which was identical to the target single-stranded amplicon and a total of 19 bacterial strains. Under optimal condition, ST3 was calibrated with a dynamic range of 0.4883–15.6250 nM. By coupling asymmetric PCR amplification, the probe-based electrochemical genosensor was highly specific to the target organism (100% specificity) and able to detect as little as 0.85 ng/μl of V. cholerae genomic DNA.  相似文献   

15.
Insulated isothermal PCR (iiPCR), established on the basis of Ralyeigh-Bénard convection, is a rapid and low-cost platform for nucleic acid amplification. However, the method used for signal detection, namely gel electrophoresis, has limited the application of iiPCR. In this study, TaqMan probe-based iiPCR system was developed to obviate the need of post-amplification processing. This system includes an optical detection module, which was designed and integrated into the iiPCR device to detect fluorescent signals generated by the probe. TaqMan probe-iiPCR assays targeting white spot syndrome virus (WSSV) and infectious myonecrosis virus were developed for preliminary evaluation of this system. Significant elevation of fluorescent signals was detected consistently among positive iiPCR reactions in both assays, correlating with amplicon detection by gel electrophoresis analysis. After condition optimization, a threshold value of S/N (fluorescent intensityafter/fluorescent intensitybefore) for positive reactions was defined for WSSV TaqMan probe-iiPCR on the basis of 20 blank reactions. WSSV TaqMan probe-iiPCR generated positive S/Ns from as low as 101 copies of standard DNA and lightly infected Litopenaeus vannamei. Compared with an OIE-certified nested PCR, WSSV TaqMan probe-iiPCR showed a sensitivity of 100% and a specificity of 96.67% in 120 WSSV-free or lightly infected shrimp samples. Generating positive signals specifically and sensitively, TaqMan probe-iiPCR system has a potential as a low-cost and rapid on-site diagnostics method.  相似文献   

16.
New methods were developed for the detection of koi herpesvirus (KHV, CyHV-3) by LAMP, which were compared with the PCR for specificity and sensitivity. We designed two primer sets targeting a specific sequence within the 9/5 PCR amplicon (9/5 LAMP) and the upper region of the Sph I-5 PCR amplicon ( Sph I-5 LAMP), including a sequence highly conserved among the strains. The amplification was monitored in real-time based on the increase in turbidity, with magnesium pyrophosphate as the by-product. The reactions were carried out under isothermal conditions at 65°C for 60 min. The detection limit of both LAMP was six copies, equal to the modified Sph I-5 PCR. No cross-reactivity with other fish pathogenic viruses and bacteria was observed. Sph I-5 LAMP was found to have a quicker response in terms of the reaction velocity than 9/5 LAMP. Therefore, we consider Sph I-5 LAMP to be superior for routine use. Additionally, LAMP was found applicable to crude extract from gills and other organs. LAMP methods are superior in terms of sensitivity, specificity, rapidity and simplicity, and are potentially a valuable diagnostic tool for KHV infections.  相似文献   

17.
Bacillus cereus group bacteria share a significant degree of genetic similarity. Thus, to differentiate and identify the Bacillus cereus group efficiently, a multiplex PCR method using the gyrB and groEL genes as diagnostic markers is suggested for simultaneous detection. The assay yielded a 400 bp amplicon for the groEL gene from all the B. cereus group bacteria, and a 253 bp amplicon from B. anthracis, 475 bp amplicon from B. cereus, 299 bp amplicon from B. thuringiensis, and 604 bp amplicon from B. mycoides for the gyrB gene. No nonspecific amplicons were observed with the DNA from 29 other pathogenic bacteria. The specificity and sensitivity of the B. cereus group identification using this multiplex PCR assay were evaluated with different kinds of food samples. In conclusion, the proposed multiplex PCR is a reliable, simple, rapid, and efficient method for the simultaneous identification of B. cereus group bacteria from food samples in a single tube.  相似文献   

18.
We describe a novel quantitative real-time (Q)-PCR assay for Listeria monocytogenes based on the coamplification of a target hly gene fragment and an internal amplification control (IAC). The IAC is a chimeric double-stranded DNA containing a fragment of the rapeseed BnACCg8 gene flanked by the hly-specific target sequences. This IAC is detected using a second TaqMan probe labeled with a different fluorophore, enabling the simultaneous monitoring of the hly and IAC signals. The hly-IAC assay had a specificity and sensitivity of 100%, as assessed using 49 L. monocytogenes isolates of different serotypes and 96 strains of nontarget bacteria, including 51 Listeria isolates. The detection and quantification limits were 8 and 30 genome equivalents, and the coefficients for PCR linearity (R2) and efficiency (E) were 0.997 and 0.80, respectively. We tested the performance of the hly-IAC Q-PCR assay using various broth media and food matrices. Fraser and half-Fraser media, raw pork, and raw or cold-smoked salmon were strongly PCR-inhibitory. This Q-PCR assay for L. monocytogenes, the first incorporating an IAC to be described for quantitative detection of a food-borne pathogen, is a simple and robust tool facilitating the identification of false negatives or underestimations of contamination loads due to PCR failure.  相似文献   

19.
Nucleic acid sequence-based amplification with electrochemiluminescent detection (NASBA/ECL) is an isothermal technique allowing rapid amplification and detection of specific regions of nucleic acid from a diverse range of sources. It is especially suitable for amplifying RNA. A NASBA/ECL technique has been developed allowing the detection of RNA from avian influenza virus subtype H7 derived from allantoic fluid harvested from inoculated chick embryos and from cell cultures. Degenerate amplification primers and amplicon capture probes were designed enabling the detection of low and highly pathogenic avian influenza of the H7 subtype from the Eurasian and North American lineages and the Australian sub-lineage. The NASBA/ECL technique is specific for subtype H7 and does not cross-react with other influenza subtypes or with viruses containing haemagglutinin-like genes. The assay is 10- to 100-fold more sensitive than a commercially available antigen capture immunoassay system. The NASBA/ECL assay could be used in high throughput poultry screening programmes.  相似文献   

20.
Phytophthora ramorum is the causal agent of sudden oak death. The pathogen also affects a wide range of tree, shrub, and herbaceous species in natural and landscaped environments as well as plants in the nursery industry. A TaqMan real-time PCR method for the detection of this pathogen in the field has been described previously; this paper describes the development of a number of assays based on this method which have various advantages for use in the field. A scorpion real-time PCR assay that is twice as fast as TaqMan was developed, allowing the detection of P. ramorum in less than 30 min. Also designed was a loop-mediated isothermal amplification (LAMP) assay, which allowed sensitive and specific detection of P. ramorum in 45 min using only a heated block. A positive reaction was identified by the detection of the LAMP product by color change visible to the naked eye.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号