1.
In this report, we present a case of a 68-year-old male who developed extensive, devastating prosthetic valve endocarditis (PVE) several months following aortic valve replacement with a tissue valve St. Jude Epic Supra. He was successfully treated with a complex surgical procedure. In the discussion, we focus on the issues of prosthetic aortic valve endocarditis and various modes of treatment.  相似文献   

2.
Rapidly growing mycobacteria are non-tuberculous mycobacteria amply present in the environment. Although they are not usually pathogenic for humans, they are opportunistic in that they can cause disease in people with disadvantageous conditions or who are immunocompromised. Mycobacterium peregrinum, an opportunistic, rapidly growing mycobacteria, belongs to the M. fortuitum group and has been reported as responsible for human cases of mycobacteriosis. A case of M. peregrinum type III is herein reported as the first in Colombia. It presented as a disseminated disease involving a prosthetic aortic valve (endocarditis) in a seventeen-year-old girl with a well-established diagnosis of prosthetic aortic valve endocarditis who was referred for a surgical replacement. Due to a congenital heart disease (subaortic stenosis with valve insufficiency), she had two previous aortic valve implantation surgeries. One year after the second implantation, the patient presented with respiratory symptoms and weight lost indicative of lung tuberculosis. A chest X-ray did not show parenchymal compromise but several Ziehl-Neelsen stains were positive. An echocardiography showed a vegetation on the prosthetic aortic valve. In blood and sputum samples, M. peregrinum type III was identified through culture, biochemical tests and hsp65 gene molecular analysis (PRA). The patient underwent a valve replacement and received a multidrug antimycobacterial treatment. Progressive recovery ensued and further samples from respiratory tract and blood were negative for mycobacteria.  相似文献   

3.
Allogenic aortic valves are widely used in case of native aortic valve or root disease as well as failed prosthetic valves with great success. At the Department of Cardiovascular Surgery and Transplantology of the Jagiellonian University in Cracow, aortic valve or aortic root replacement with allogenic aortic valve has been performed for 23 years. Allogenic heart valve bank was founded in 1980. In the bank we prepare both aortic allografts for adult cardiac surgical procedures and pulmonary allografts that are mostly used for repair of congenital heart disease.Allogenic aortic valves implantation was usually considered in our clinic for older patients, patients with infective endocarditis of the native or prosthetic valve, young women in reproductive age and patients with Marfan syndrome. Allografts exhibit excellent clinical performance and acceptable durability with no early failure if properly inserted. Between 1980 and 1992, allografts were obtained only from cadavers during routine autopsies. More than 10% of prepared allografts were exported to other cardiac surgery centres in Poland and foreign countries.Aortic valve replacement using allogenic aortic valves can be performed with acceptable mortality and good long-term results. The procedure although surgically more challenging has the advantage of not requiring anticoagulation therapy, hemodynamic performance of the allogenic valve is excellent, it demonstrates freedom from thromboembolism and infective endocarditis. We would like to emphasize the importance and advantages of the fact that allogenic heart valve bank is placed in the department of cardiovascular surgery and it is able to supply the department in heart valve allografts 24 h a day.  相似文献   

4.
In Marfan syndrome, with dilatation of the aortic root secondary to an underlying connective tissue defect, pregnancy can cause hemodynamic stress leading to the development of an aortic aneurysm and even a fatal aortic dissection. In the presence of existing aortic root enlargement and a family history of aortic dissection, preventative elective surgery is suggested. Aortic root replacement with or without a valve-sparing procedure is superior to total aortic root replacement with prosthetic valve/tube graft. It provides excellent survival with low rates of aortic - valve related complications.  相似文献   

5.
Elevated turbulent shear stresses resulting from disturbed blood flow through prosthetic heart valves can cause damage to red blood cells and platelets. The purpose of this study was to measure the turbulent shear stresses occurring downstream of aortic prosthetic valves during in-vitro pulsatile flow. By matching the indices of refraction of the blood analog fluid and model aorta, correlated, simultaneous two-component laser velocimeter measurements of the axial and radial velocity components were made immediately downstream of two aortic prosthetic valves. Velocity data were ensemble averaged over 200 or more cycles for a 15-ms window opened at peak systolic flow. The systolic duration for cardiac flows of 8.4 L/min was 200 ms. Ensemble-averaged total shear stress levels of 2820 dynes/cm2 and 2070 dynes/cm2 were found downstream of a trileaflet valve and a tilting disk valve, respectively. These shear stress levels decreased with axial distance downstream much faster for the tilting disk valve than for the trileaflet valve.  相似文献   

6.
A 66-year-old woman developed severe hemolysis after undergoing aortic valve replacement. A diminutive annulus and extensive calcification of the aorta precluded further surgery of the aortic root. Hemolysis was completely reversed by the implantation of a woven Dacron apicoabdominal aortic conduit incorporating a Cooley-Cutter prosthetic valve. Fractionation of stroke volume by means of a second ventricular outlet can reduce shear stresses and turbulence associated with unfavorable hemodynamic conditions, thereby successfully correcting hemolysis.  相似文献   

7.
Acquired aortic disease is now currently corrected by total prosthetic replacement of the aortic valve. Aortic valve replacement was performed in 13 cases at the Montreal Heart Institute in 1963. In the first four cases, Bahnson aortic leaflets were used; in the remaining nine, the Starr-Edwards semirigid aortic valve prosthesis. The surgical technique employed is described. There were two operative deaths and two late deaths. The results have been excellent in all of the survivors but one. They have returned to full-time activities and four of them to strenuous physical work. It is the contention of the authors that aortic valve replacement is a surgical procedure with acceptable risks, offering hope for a near-normal life to patients crippled by severe aortic valvular lesions.  相似文献   

8.
TAVI devices are manufactured with cylindrical frames. However, the frames are rarely cylindrical post-deployment since deformation due to localised under expansion can be induced by calcified material on the native valve leaflets exerting irregular forces upon the frame. Consequently, the leaflets within a deformed TAVI device may undergo elevated stress during operation, which may lead to premature device failure.Using computational analysis a complete TAVI device model was simulated undergoing deployment into an aortic root model derived from CT data for a patient with severe calcific aortic stenosis, followed by a pressure simulated cardiac cycle. The complete analysis was performed eight times, each with the device at a different rotational orientation relative to the native valve, with an increment spacing of 15°.The TAVI device frames consistently featured significant distortions associated with bulky calcified material at the base of the non-coronary sinus. It was found that the average von Mises stress in the prosthetic valves was only increased in one of the cases relative to an idealised device. However, the maximum von Mises stress in the prosthetic valves was elevated in the majority of the cases.Furthermore, it was found that there were preferable orientations to deploy the prosthetic device, in this case, when the prosthetic leaflets were aligned with the native leaflets. As device orientation deviated from this orientation, the stresses in the valve increased because the distance between the prosthetic commissures decreased. This potentially could represent a sufficient increase in stress to induce variation in device lifespan.  相似文献   

9.
Two studies are described comparing the inlet and outlet diameters of the normal aortic valve. Both studies show the valve inlet to be smaller than the valve outlet. The first study is of measurements made on 12 casts of physiologically pressurised human aortic valves. The mean ratio between the diameter of the aortic ring and of the aorta just distal to the sinus ridge was 1.1, and the mean ratio between the diameter of the aortic ring and the maximum diameter of the valve leaflets was 1.18. The second study presents echocardiographic data from normal volunteers. The mean ratio between the diameter of the aortic ring and of the aorta just distal to the sinus ridge was 1.17. It is suggested that stents made to support the leaflets of prosthetic valves are made in conical or hyperbolic form, with the outlet being approximately 20% larger than the inlet.  相似文献   

10.
Computational simulation of transcatheter aortic valve implantation (TAVI) device deployment presents a significant challenge over and above similar simulations for percutaneous coronary intervention due to the presence of prosthetic leaflets. In light of the complexity of these leaflets, simulations have been performed to assess the effect of including the leaflets in a complete model of a balloon-expandable TAVI device when deployed in a patient-specific aortic root. Using an average model discrepancy metric, the average frame positions (with and without the leaflets) are shown to vary by 0.236% of the expanded frame diameter (26 mm). This relatively small discrepancy leads to the conclusion that for a broad range of replacement valve studies, including new frame configurations and designs, patient-specific assessment of apposition, paravalvular leakage and tissue stress, modelling of the prosthetic leaflets is likely to have a marginal effect on the results  相似文献   

11.
The dimensions of the aortic valve components condition its ability to prevent blood from flowing back into the heart. While the theoretical parameters for best trileaflet valve performance have already been established, an effective approach to describe other less optimal, but functional models has been lacking. Our goal was to establish a method to determine by how much the dimensions of the aortic valve components can vary while still maintaining proper function. Measurements were made on silicone rubber casts of human aortic valves to document the range of dimensional variability encountered in normal adult valves. Analytical equations were written to describe a fully three-dimensional geometric model of a trileaflet valve in both the open and closed positions. A complete set of analytical, numerical and graphical tools was developed to explore a range of component dimensions within functional aortic valves. A list of geometric guidelines was established to ensure safe operation of the valve during the cardiac cycle, with practical safety margins. The geometry-based model presented here allows determining quickly if a certain set of valve component dimensions results in a functional valve. This is of great interest to designers of new prosthetic heart valve models, as well as to surgeons involved in valve-sparing surgery.  相似文献   

12.
To determine the extent of backflow encountered with currently used prosthetic valves, four types of aortic valves with comparable orifice diameters were tested in a pulse duplicating system. These were a Hancock porcine valve, a Lillehei-Kaster pivoting disk valve, a St. Jude bileaflet valve and a Bj?rk-Shiley tilting disk valve. Mean aortic pressure was sequentially increased from 83 to 147 mmHg, keeping the pump rate essentially constant (69-73 strokes/min). The porcine valve produced the least amount of total backflow (backflow due to closure plus leakage backflow) (1.6 to 2.4 mL/stroke). Among the mechanical valves the Bj?rk-Shiley valve showed the least amount of total backflow (5.0 to 6.0 mL/stroke). At a mean aortic pressure of 100 mmHg and a low cardiac output of 2 L/min, the total backflow with the porcine valve was only 6 percent of forward flow; whereas it was 19 percent with the Lillehei-Kaster valve, 22 percent with the St. Jude valve and 18 percent with the Bj?rk-Shiley valve. Leakage backflow at a given level of mean aortic pressure was, as expected, directly related to the annular clearance area. It is concluded that the Hancock valve showed the least amount of backward flow, which would be particularly beneficial in low output states. In the presence of normal hemodynamics, the amount of backflow with the three mechanical valves appeared to be well below the level of backflow considered to be clinically significant.  相似文献   

13.
A. S. Trimble  F. N. Metni 《CMAJ》1971,105(7):715-717
Since November 1969, 53 patients have been operated on at the Toronto General Hospital for cardiac valve replacement with valves fashioned from autologous fascia lata. Sixty-three such valves have been inserted, including single aortic and mitral, double and triple valve replacements. The preliminary results indicate that operative mortality, considering the status of the patient submitted to the procedure, is comparable to that of plastic prosthetic valve replacement at this centre. Early follow-up confirms that anticoagulation is unnecessary and thromboembolism can be avoided with this form of valve substitution.  相似文献   

14.
Limitations of currently available prosthetic valves, xenografts, and homografts have prompted a recent resurgence of developments in the area of tri-leaflet polymer valve prostheses. However, identification of a protocol for initial assessment of polymer valve hydrodynamic functionality is paramount during the early stages of the design process. Traditional in vitro pulse duplicator systems are not configured to accommodate flexible tri-leaflet materials; in addition, assessment of polymer valve functionality needs to be made in a relative context to native and prosthetic heart valves under identical test conditions so that variability in measurements from different instruments can be avoided. Accordingly, we conducted hydrodynamic assessment of i) native (n = 4, mean diameter, D = 20 mm), ii) bi-leaflet mechanical (n= 2, D = 23 mm) and iii) polymer valves (n = 5, D = 22 mm) via the use of a commercially available pulse duplicator system (ViVitro Labs Inc, Victoria, BC) that was modified to accommodate tri-leaflet valve geometries. Tri-leaflet silicone valves developed at the University of Florida comprised the polymer valve group. A mixture in the ratio of 35:65 glycerin to water was used to mimic blood physical properties. Instantaneous flow rate was measured at the interface of the left ventricle and aortic units while pressure was recorded at the ventricular and aortic positions. Bi-leaflet and native valve data from the literature was used to validate flow and pressure readings. The following hydrodynamic metrics were reported: forward flow pressure drop, aortic root mean square forward flow rate, aortic closing, leakage and regurgitant volume, transaortic closing, leakage, and total energy losses. Representative results indicated that hydrodynamic metrics from the three valve groups could be successfully obtained by incorporating a custom-built assembly into a commercially available pulse duplicator system and subsequently, objectively compared to provide insights on functional aspects of polymer valve design.  相似文献   

15.
A. G. de la Rocha  S. K. Plume  R. J. Baird 《CMAJ》1977,116(10):1158-1160
Thrombotic malfunction of a Björk-Shiley aortic valve prosthesis occurred in three patients 6 to 16 months postoperatively. None of the patients had been taking anticoagulants. Although the presentation was acute, prodromal symptoms could be identified retrospectively in two of the patients. Two patients survived thrombectomy. Postoperative anticoagulant therapy is recommended in patients with these prostheses despite factors that may make such therapy riskier in specific patients. Attention to the character of murmurs and of the closure sound of the prosthetic valve must be part of the routine follow-up. In the emergency situation, when delay must be avoided, catheterization and angiography are unnecessary. The operative approach consists of complete thrombectomy without replacement of the valve or any of its components unless there is obvious periprosthetic leak or prosthetic wear.  相似文献   

16.
Heavily calcified annuli increase the incidence of complications after prosthetic valve replacement—heart block, separation of the aorta or the atrium from the ventricle, late aneurysm formation, paravalvular leak, and haemolysis. An ultrasonic calculus-disintegrator has been developed to remove calcific deposits. The instrument is portable, robust, easily sterilized, inexpensive, and provides nebulized water at the ultrasonic tip which keeps the tissues cool, helps to break up the calculus by cavitation, and washes the calcific debris into the sucker. Preliminary trial on excised calcific valves showed the ultrasound instrument to be capable of removing most forms of calcification. In clinical prosthetic replacement of valves it enabled good clearance of the annulus to be performed in six out of seven cases, in one of which earlier operation had been unsuccessful because of calcification. Two elderly patients with pure calcific aortic stenosis were successfully treated by debridement of the aortic valve with ultrasound.  相似文献   

17.
This report describes a patient with a combined infection due to Pseudallescheria boydii and Clostridium limosum on a prosthetic dura mater aortic valve homograft. While this patient had C. limosum only growing in blood cultures, both organisms were isolated from the surgically resected aortic valve. Because P. boydii is generally resistant to amphotericin B but susceptible to miconazole, accurate differentiation of P. boydii from other fungi which may appear similarly in tissue sections (e.g., aspergillus) is important.  相似文献   

18.
Stresses in a prosthetic heart valve at closure are determined by its geometrical and structural characteristics, by the mechanical support environment, and by the momentum of the valve leaflets or occluder and of the blood at the instant of closure. The mass of blood to be arrested is significantly greater than that of the leaflets or occluder, and is therefore likely to dominate the closure impulse. The kinetic energy of the blood must be transduced into potential energy in the structural components (valve leaflets, aortic root and aorta). This paper presents a methodology for computation and parameterisation of the blood momentum associated with a valve in the aortic position. It is suggested that the influence of physiological parameters, such as systolic waveform and systemic impedance, on the closure characteristics can be investigated based on the fluid dynamic implications. Detailed results are presented for a single leaflet mechanical valve (Bjork-Shiley 60 degrees Convexo-Concave). It is demonstrated that a simple analytical method can yield results that might be adequate for the purposes of valve design.  相似文献   

19.
Turbulent flow simulations are run for five aortic trileaflet valve geometries, ranging from a valve leaflet orifice area of 1.1 cm2 (Model A1—very stenotic) to 5.0 cm2 (Model A5—natural valve). The simulated data compares well with experimental measurements made downstream of various aortic trileaflet valves by Woo (PhD Thesis, 1984). The location and approximate width and length of recirculation regions are correctly predicted. The less stenotic valve models reattach at the end of the aortic sinus region, 1.1 diameters downstream of the valve. The central jet exiting the less stenotic valve models is not significantly different from fully developed flow, and therefore recovers very quickly downstream of the reattachment point. The more stenotic valves disturb the flow to a greater degree, generating recirculation regions large enough to escape the sinuses and reattach further downstream. Peak turbulent shear stress values downstream of the aortic valve models which approximated prosthetic valves are 125 and 300 N m−2, very near experimental observations of 150 to 350 N m−2. The predicted Reynolds stress profiles also present the correct shape, a double peak profile, with the location of the peak occuring at the location of maximum velocity gradient, which occurs near the recirculation region. The pressure drop across model A2 (leaflet orifice area 1.6 cm2) is 20 mmHg at 1.6 diameters downstream. This compares well with values ranging from 19.5 to 26.2 mmHg for valves of similar orifice areas. The pressure drop decreases with decreasing valve stenosis, to a negligible value across the least stenotic valve model. Based on the good agreement between experimental measurements of velocity, shear stress and pressure drop, compared to the simulated data, the model has the potential to be a valuable tool in the analysis of heart valve designs.  相似文献   

20.
The velocity fields downstream of four prosthetic heart valves were mapped in vitro over the entire cross-section of a model aortic root using laser Doppler anemometry. THe Bj?rk-Shiley 60 degrees convexo-concave tilting disc valve, the Smeloff-Cutter caged ball valve, the St. Jude Medical bileaflet valve, and the Ionescu-Shiley standard bioprosthesis were examined under both steady and pulsatile flows. Velocity profiles under steady flow conditions were a good approximation for pulsatile profiles only during midsystole. The pulsatile flow characteristics of the four valves showed variation in large scale flow structures. Comparison of the valves according to pressure drop, shear stress and maximum velocities are also provided.  相似文献   