1.
Measurement of bone mineral density (BMD) by DXA (dual-energy X-ray absorptiometry) is generally considered to be the clinical golden standard technique to diagnose osteoporosis. However, BMD alone is only a moderate predictor of fracture risk. Finite element analyses of bone mechanics can contribute to a more accurate prediction of fracture risk. In this study, we applied a method to estimate the 3D geometrical shape of bone based on a 2D BMD image and a femur shape template. Proximal femurs of eighteen human cadavers were imaged with computed tomography (CT) and divided into two groups. Image data from the first group (N = 9) were applied to create a shape template by using the general Procrustes analysis and thin plate splines. This template was then applied to estimate the shape of the femurs in the second group (N = 9), using the 2D BMD image projected from the CT image, and the geometrical errors of the shape estimation method were evaluated. Finally, finite element analysis with stance loading condition was conducted based on the original CT and the estimated geometrical shape to evaluate the effect of the geometrical errors on the outcome of the simulations. The volumetric errors induced by the shape estimation method itself were low (<0.6%). Increasing the number of bone specimens used for the template decreased the geometrical errors. When nine bones were used for the template, the mean distance difference (±SD) between the estimated and the CT shape surfaces was 1.2 ± 0.3 mm, indicating that the method was feasible for estimating the shape of the proximal femur. Small errors in geometry led systematically to larger errors in the mechanical simulations. The method could provide more information of the mechanical characteristics of bone based on 2D BMD radiography and could ultimately lead to more sensitive diagnosis of osteoporosis.  相似文献   

2.
Computed tomography (CT)-based finite element (FE) models may improve the current osteoporosis diagnostics and prediction of fracture risk by providing an estimate for femoral strength. However, the need for a CT scan, as opposed to the conventional use of dual-energy X-ray absorptiometry (DXA) for osteoporosis diagnostics, is considered a major obstacle. The 3D shape and bone mineral density (BMD) distribution of a femur can be reconstructed using a statistical shape and appearance model (SSAM) and the DXA image of the femur. Then, the reconstructed shape and BMD could be used to build FE models to predict bone strength. Since high accuracy is needed in all steps of the analysis, this study aimed at evaluating the ability of a 3D FE model built from one 2D DXA image to predict the strains and fracture load of human femora. Three cadaver femora were retrieved, for which experimental measurements from ex vivo mechanical tests were available. FE models were built using the SSAM-based reconstructions: using only the SSAM-reconstructed shape, only the SSAM-reconstructed BMD distribution, and the full SSAM-based reconstruction (including both shape and BMD distribution). When compared with experimental data, the SSAM-based models predicted accurately principal strains (coefficient of determination >0.83, normalized root-mean-square error <16%) and femoral strength (standard error of the estimate 1215 N). These results were only slightly inferior to those obtained with CT-based FE models, but with the considerable advantage of the models being built from DXA images. In summary, the results support the feasibility of SSAM-based models as a practical tool to introduce FE-based bone strength estimation in the current fracture risk diagnostics.  相似文献   

3.
Skeletal fractures associated with bone mass loss are a major clinical problem and economic burden, and lead to significant morbidity and mortality in the ageing population. Clinical image-based measures of bone mass show only moderate correlative strength with bone strength. However, engineering models derived from clinical image data predict bone strength with significantly greater accuracy. Currently, image-based finite element (FE) models are time consuming to construct and are non-parametric. The goal of this study was to develop a parametric proximal femur FE model based on a statistical shape and density model (SSDM) derived from clinical image data. A small number of independent SSDM parameters described the shape and bone density distribution of a set of cadaver femurs and captured the variability affecting proximal femur FE strength predictions. Finally, a three-dimensional FE model of an 'unknown' femur was reconstructed from the SSDM with an average spatial error of 0.016 mm and an average bone density error of 0.037 g/cm(3).  相似文献   

4.
The decrease of bone mineral density (BMD) is a multifactorial bone pathology, commonly referred to as osteoporosis. The subsequent decline of the bone's micro-structural characteristics renders the human skeletal system, and especially the hip, susceptible to fragility fractures. This study represents a systematic attempt to correlate BMD spectrums to the mechanical strength characteristics of the femoral neck and determine a fracture risk indicator based on non-invasive imaging techniques. The BMD of 30 patients' femurs was measured in vivo by Dual-energy X-ray absorptiometry (DXA). As these patients were subjected to total hip replacement, the mechanical strength properties of their femurs' were determined ex-vivo using uniaxial compression experiments. FEA simulations facilitated the correlation of the DXA measurements to the apparent fracture risk, indicating critical strain values during complex loading scenarios.  相似文献   

5.
With the prevalent use of DXA-measured BMD to assess pathologic hip fractures and its recently reported lack of reliability to predict fracture or account for efficacy of anti-resorptive therapy, it is reasonable to assess whether variations in the primary and secondary tensile and compressive trabecular microstructure can account for variations in proximal femur strength in comparison to DXA-measured BMD. To that end, microstructural and densitometric measures of trabecular bone specimens, from discrete sites within the proximal femur, were correlated with their mechanical properties. We hypothesize that accounting for regional variations in trabecular microstructure will improve predictions of proximal femur strength and stiffness compared to bone density measured by DXA. Forty-seven samples (seven donors) from seven distinct sites of human proximal femur underwent DXA and muCT imaging and mechanical testing. The results revealed significant variations in BMC, morphometric indices and mechanical properties within the proximal femur. This work has demonstrated that the mechanical performance of each sub-region is highly dependent on the corresponding trabecular microstructure. BMD measured by DXA at standard regions of interest cannot resolve the variations in trabecular density and microstructure that govern the mechanical behavior of the proximal femur. This work suggests that a quantitative Singh index that uses high resolution QCT to monitor the trabecular microstructure at specific sub-regions of the proximal femur may allow better predictions of hip fracture risk in individual patients and an improved assessment of changing bone structure in response to pharmacological interventions.  相似文献   

6.
It has been recently suggested that mechanical loads applied at frequencies close to the natural frequencies of bone could enhance bone apposition due to the resonance phenomenon. Other applications of bone modal analysis are also suggested. For the above-mentioned applications, it is important to understand how patient-specific bone shape and density distribution influence the natural frequencies of bones. We used finite element models to study the effects of bone shape and density distribution on the natural frequencies of the femur in free boundary conditions. A statistical shape and appearance model that describes shape and density distribution independently was created, based on a training set of 27 femora. The natural frequencies were then calculated for different shape modes varied around the mean shape while keeping the mean density distribution, for different appearance modes around the mean density distribution while keeping the mean bone shape, and for the 27 training femora. Single shape or appearance modes could cause up to 15% variations in the natural frequencies with certain modes having the greatest impact. For the actual femora, shape and density distribution changed the natural frequencies by up to 38%. First appearance mode that describes the general cortical bone thickness and trabecular bone density had one of the strongest impacts. The first appearance mode could therefore provide a sensitive measure of general bone health and disease progression. Since shape and density could cause large variations in the calculated natural frequencies, patient-specific FE models are needed for accurate estimation of bone natural frequencies.  相似文献   

7.

Objective

This study compared the capabilities of dual-energy X-ray absorptiometry (DXA) and dental cone-beam computed tomography (CBCT) for predicting the cortical bone strength of rat femurs and tibias.

Materials and Methods

Specimens of femurs and tibias obtained from 14 rats were first scanned with DXA to obtain the areal bone mineral density (BMD) of the midshaft cortical portion of the bones. The bones were then scanned using dental CBCT to measure the volumetric cortical bone mineral density (vCtBMD) and the cross-sectional moment of inertia (CSMI) for calculating the bone strength index (BSI). A three-point bending test was conducted to measure the fracture load of each femur and tibia. Bivariate linear Pearson analysis was used to calculate the correlation coefficients (r values) among the CBCT measurements, DXA measurements, and three-point bending parameters.

Results

The correlation coefficients for the associations of the fracture load with areal BMD (measured using DXA), vCtBMD (measured using CBCT), CSMI (measured using CBCT), and BSI were 0.585 (p = 0.028) and 0.532 (p = 0.050) (for the femur and tibia, respectively), 0.638 (p = 0.014) and 0.762 (p = 0.002), 0.778 (p = 0.001) and 0.792 (p<0.001), and 0.822 (p<0.001) and 0.842 (p<0.001), respectively.

Conclusions

CBCT was found to be superior to DXA for predicting cortical bone fracture loads in rat femurs and tibias. The BSI, which is a combined index of densitometric and geometric parameters, was especially useful. Further clinical studies are needed to validate the predictive value of BSI obtained from CBCT and should include testing on human cadaver specimens.  相似文献   

8.
Femoral radiographs are affected by the degree of rotation of the femur with respect to the plane of projection. We aimed to determine the 3D rotation of the proximal femur in 2D radiographs. A 3D Statistical Appearance Model (SAM), which was built from CT images of cadaver proximal femurs (n=33) was randomly sampled to form a training set of 500 bones. Nineteen clinical CT images were collected for testing. All CT images were rotated to ±20° in 2° division around the shaft axis, ±10° around medial-lateral axis, and by simultaneous rotation of both axes (±16° and ±8° around shaft and medial-lateral axes). In each orientation, a 2D projection was recorded for generating a 2D SAM. The outcome parameters of the 2D SAM were used as input for a linear regression model and an artificial neural network to predict the rotation. The artificial neural network estimated the rotation more accurately than the linear regression. For artificial neural networks the mean errors were 4.0° and 2.0° around the shaft and medial-lateral axes, respectively. For an individual radiograph, the confidence interval of estimation was still relatively large. However, this method has high potential to differentiate the amount of rotations in two image sets.  相似文献   

9.
PurposeTo experimentally validate a non-linear finite element analysis (FEA) modeling approach assessing in-vitro fracture risk at the proximal femur and to transfer the method to standard in-vivo multi-detector computed tomography (MDCT) data of the hip aiming to predict additional hip fracture risk in subjects with and without osteoporosis associated vertebral fractures using bone mineral density (BMD) measurements as gold standard.MethodsOne fresh-frozen human femur specimen was mechanically tested and fractured simulating stance and clinically relevant fall loading configurations to the hip. After experimental in-vitro validation, the FEA simulation protocol was transferred to standard contrast-enhanced in-vivo MDCT images to calculate individual hip fracture risk each for 4 subjects with and without a history of osteoporotic vertebral fractures matched by age and gender. In addition, FEA based risk factor calculations were compared to manual femoral BMD measurements of all subjects.ResultsIn-vitro simulations showed good correlation with the experimentally measured strains both in stance (R2 = 0.963) and fall configuration (R2 = 0.976). The simulated maximum stress overestimated the experimental failure load (4743 N) by 14.7% (5440 N) while the simulated maximum strain overestimated by 4.7% (4968 N). The simulated failed elements coincided precisely with the experimentally determined fracture locations. BMD measurements in subjects with a history of osteoporotic vertebral fractures did not differ significantly from subjects without fragility fractures (femoral head: p = 0.989; femoral neck: p = 0.366), but showed higher FEA based risk factors for additional incident hip fractures (p = 0.028).ConclusionFEA simulations were successfully validated by elastic and destructive in-vitro experiments. In the subsequent in-vivo analyses, MDCT based FEA based risk factor differences for additional hip fractures were not mirrored by according BMD measurements. Our data suggests, that MDCT derived FEA models may assess bone strength more accurately than BMD measurements alone, providing a valuable in-vivo fracture risk assessment tool.  相似文献   

10.
Estimating the risk of osteoporotic fractures is an important diagnostic step that needs to be taken before medicinal treatment. Densitometry-based criteria are normally used in clinical practice for this purpose. However, densitometry-based techniques could not explain all low-energy fractures. As patient-specific finite element (FE) models allow for consideration of other parameters (e.g. load conditions) that are known to be associated with fracture, they are considered promising candidates for more accurate fracture risk estimation. Nevertheless, they are often time consuming, expensive, and complex to build and may need the type of expertise that is not normally available in clinical settings. In this study, we report the development of an automated platform for estimating proximal femur fracture loads using patient-specific 2D FE models generated using dual-energy x-ray absorptiometry (DXA) scans. First, a statistical shape and appearance model (SSAM) is built using DXA scans of patients screened for osteoporosis following a low energy fracture. SSAM is then used together with Active Appearance Models (AAM) for automated segmentation of the proximal femur from new unseen DXA scans. The mean point-to-curve error of the automated procedure, i.e. 1.2–1.4 mm, is shown to be only slightly larger than the intra-observer variability of manual segmentation, i.e. 1.0 mm. Moreover, the developed platform automatically meshes the segmented shape, assigns density-based mechanical properties, assigns loads and boundary conditions, submits the 2D FE model for solution, and performs post-processing of the 2D FE simulation data to determine fracture loads. The fracture loads predicted using the manually generated and automatically generated 2D FE models are shown to be very close with a mean difference of around 8.8%. Repeated measures ANOVA showed no significant differences between the fracture loads calculated using FE models manually generated by three independent observers and those calculated using the automatically generated FE models (p>0.05).  相似文献   

11.
This investigation of microstructure in the human proximal femur probes the relationship between the parameters of the FRAX index of fracture risk and the parameters of bone microstructure. The specificity of fracture sites at the proximal femur raises the question of whether trabecular parameters are site-specific during post-menopause, before occurrence of fragility fracture. The donated proximal femurs of sixteen post-menopausal women in the sixth and seventh decades of life, free of metabolic pathologies and therapeutic interventions that could have altered the bone tissue, constituted the material of the study. We assessed bone mineral density of the proximal femurs by dual energy X-ray absorptiometry and then sectioned the femurs through the center of the femoral head and along the femoral neck axis. For each proximal femur, morphometry of trabeculae was conducted on the plane of the section divided into conventional regions and sub-regions consistent with the previously identified trabecular families that provide regions of relatively homogeneous microstructure. Mean trabecular width and percent bone area were calculated at such sites. Our findings indicate that each of mean trabecular width and percent bone area vary within each proximal femur independently from each other, with dependence on site. Both trabecular parameters show significant differences between pairs of sites. We speculate that a high FRAX index at the hip corresponds to a reduced percent bone area among sites that gives a more homogeneous and less site-specific quality to the proximal femur. This phenomenon may render the local tissue less able to carry out the expected mechanical function.  相似文献   

12.
INTRODUCTION: Osteopenia and osteoporosis because of hyperprolactinaemia caused by prolactinoma may be followed by an increased risk of fracture. There are no data on the bone effects of functional hyperprolactinaemia. The aim was to assess the influence of hyperprolactinaemia of various origins on bone turnover and density in different skeletal sites. MATERIAL AND METHODS: The study was carried out in 75 women (aged 30.53 +/- 7.8): Group I--32 women with prolactinoma and Group II--43 women with functional hyperprolactinaemia. Both groups of patients were subdivided into those with hypogonadism and those with normal gonadal function. The control group consisted of 29 healthy women aged (33.59 +/- 4.7). In all subjects PRL and bone turnover markers (BAP, OC, ICTP) were studied. BMD measurements (lumbar spine, forearm, proximal femur and total body) were carried out using DXA. RESULTS: Higher PRL concentrations were observed in patients than in controls. The values of bone turnover markers (BAP, ICTP) were shown to be higher in patient groups and subgroups than in controls. In patients with prolactinoma lumbar spine BMD was lower than in patients with functional hyperprolactinaemia and controls. Total body BMD was also lower, albeit to a lesser extent. CONCLUSIONS: Hyperprolactinaemia caused by prolactinoma in women influences bone metabolism unfavourably, more by the impact on the activity of bone turnover markers than on BMD. This provides an opportunity for earlier assessment of bone metabolism disturbances before the BMD changes can be observed. Functional hyperprolactinaemia does not determine such a harmful effect on bone metabolism as hyperprolactinemia due to prolactinoma.  相似文献   

13.
OBJECTIVE: To investigate the effect of dexamethasone eye drops on bone metabolism in newborn rabbits. METHODS: Thirty-four 3-week-old rabbits had unilateral clear lens extraction and were randomized into three groups. Postoperatively, group 1 received high-dose and group 2 low-dose dexamethasone eye drops (average doses 0.27 and 0.10 mg/kg body weight/day, respectively). These rabbits also received a postoperative subconjunctival injection of betamethasone. Group 3 (control) received vehicle eye drops only. After 8 weeks of treatment, all animals were killed and the left femurs were isolated and subjected to peripheral quantitative computerized tomography (pQCT) and dual X-ray absorptiometry (DXA) analyses. RESULTS: DXA showed that rabbits treated with either a high or low dose of dexamethasone eye drops had significantly reduced areal bone mineral density (BMD), area and total bone mineral content (BMC) of the femur. Measurements with pQCT demonstrated a dose-dependent reduction in cortical BMC, cortical volumetric BMD and cortical area. These effects were associated with an inhibition of radial femur growth, cortical thickness and periosteal and endosteal circumferences. CONCLUSION: Dexamethasone eye drops have systemic effects affecting several bone parameters in young rabbits. Any long-term systemic effects of ocular glucocorticoids need to be further studied.  相似文献   

14.
15.
A mandatory requirement for any reliable prediction of the mechanical response of bones, based on quantitative computer tomography, is an accurate relationship between material properties (usually Young's modulus E) and bone density ρ. Many such E-ρ relationships are available based on different experiments on femur specimens with a large spread due to uncertainties. The first goal of this study is to pool and analyze the relevant available experimental data and develop a stochasticE-ρ relationship. This analysis highlights that there is no experimental data available to cover the entire density range of the human femur and that some "popular" E-ρ relationships are based on data that contains extreme scatter, while others are based on a very limited amount of information. The second goal is to use the newly developed stochastic E-ρ relationship in high-order finite element analyses (FEAs) for the computation of strains and displacements in two human proximal femurs, mimicking in vitro experiments. When compared with the experimental observations, the FEA predictions using the median of the stochastic E-ρ relationship follow the underlying distribution of the stochastic E-ρ relationship. Thus, most deviations of the FEA predictions from experimental observations can possibly be explained by uncertain elastic properties of the femur.  相似文献   

16.
The purpose of this study was to perform a comprehensive geometric, densitometric, biomechanical, and statistical analysis of paired femurs for an adult population over a wide age range using three imaging modalities to quantify the departure from symmetry in size, bone mineral density, and cross-sectional structural rigidities.Femur measurements were obtained from 20 pairs of cadaveric femurs. Dimensions of these anatomic sites were measured using calipers directly on the bone and plain radiographs. Dual energy X-ray absorptiometry was used to measure bone mineral density. Bone mineral content and axial and bending rigidities were determined from the CT imaging.No differences were observed between the geometric measurements, DXA based bone mineral density and axial and bending rigidities of left and right femurs (P>0.05 for all cases). Left and right proximal femurs are not significantly different based on geometric, densitometric, and structural rigidity measurements. However, absolute left–right differences for individual patients can be substantial. When using the contralateral femur as a control, the number of femur pairs required to assess significant changes in anatomic dimensions and structural properties induced by a tumor, infection, fracture, or implanted device can range from 3 to 165 pairs depending on the desired effect size or sensitivity (5% or 10% difference).This information is important both for femoral arthroplasty implant design and the use of the contralateral femur as an intra-subject control for clinical assessment and research studies. In addition, our statistical analysis provides sample size estimates for planning future orthopedic research studies.  相似文献   

17.
The variation in several of the risk factors for osteoporotic fracture, including bone mineral density (BMD), has been shown to be strongly influenced by genetic differences. However, the genetic architecture of BMD is complex in both humans and in model organisms. We previously reported quantitative trait locus (QTL) results for BMD from a genome screen of 828 F2 progeny of Copenhagen and dark agouti rats. These progeny also provide an excellent opportunity to search for epistatic effects, or interaction between genetic loci, that contribute to fracture risk. Microsatellite marker data from a 20-cM genome screen was analyzed along with weight-adjusted bone density (DXA and pQCT) phenotypic data using the R/qtl software package. Genotype and phenotype data were permuted to determine genome-wide significance thresholds for the full model and epistasis (interaction) LOD scores corresponding to an alpha level of 0.01. A novel locus on chromosome 15 and a previously reported chromosome 14 QTL demonstrated a strong epistatic effect on BMD at the femur by DXA (LOD = 5.4). Two novel QTLs on chromosomes 2 and 12 were found to interact to affect total BMD at the femur midshaft by pQCT (LOD = 5.0). These results provide new information regarding the mode of action of previously identified QTL in the rat, as well as identifying novel loci that act in combination with known QTL or with other novel loci to contribute to BMD variation.  相似文献   

18.
Differences in the mineral fraction of the fat-free mass (M(FFM)) and in the density of the FFM (D(FFM)) are often inferred from measures of bone mineral content (BMC) or bone mineral density (BMD). We studied the relation of BMC and BMD to the M(FFM) and D(FFM) in a heterogeneous sample of 216 young men (n = 115) and women (n = 101), which included whites (n = 155) and blacks (n = 61) and collegiate athletes ( n = 132) and nonathletes (n = 84). Whole body BMC and BMD were determined by dual-energy X-ray absorptiometry (DXA; Hologic QDR-1000W, enhanced whole body analysis software, version 5.71). FFM was estimated using a four-component model from measures of body density by hydrostatic weighing, body water by deuterium dilution, and bone mineral by DXA. There was no significant relation of BMD to M(FFM) (r = 0.01) or D(FFM) (r = -0.06) or of BMC to M(FFM) (r = -0.11) and a significant, weak negative relation of BMC to D(FFM) (r = -0.14, P = 0.04) in all subjects. Significant low to moderate relationships of BMD or BMC to M(FFM) or D(FFM) were found within some gender-race-athletic status subgroups or when the effects of gender, race, and athletic status were held constant using multiple regression, but BMD and BMC explained only 10-17% of the variance in M(FFM) and 0-2% of the variance in D(FFM) in addition to that explained by the demographic variables. We conclude that there is not a significant positive relation of BMD and BMC to M(FFM) or D(FFM) in young adults and that BMC and BMD should not be used to infer differences in M(FFM) or D(FFM).  相似文献   

19.
Pelvic fractures resulting from automotive side impacts are associated with high mortality and morbidity, as well as substantial economic costs. Previous experimental studies have produced varying results regarding the tolerance of the pelvis to lateral force and compression. While bone mineral density (BMD) has been shown to correlate with fracture loads in the proximal femur, no such correlation has been established for the pelvis. Presently, we studied the relationships between total hip BMD and impact response parameters in lateral impacts of twelve isolated human pelves. The results indicated that total hip BMD significantly correlated with fracture force, Fmax, and maximum ring compression, Cmax, of the fractured pelves. These findings are evidence that BMD may be useful in assessing the risk of pelvic fracture in automotive side impacts. Poor correlation was observed between total hip BMD and maximum viscous response, (VC)max, energy at fracture, Epeak, and time to fracture, tpeak. Mean Fmax and calculated tolerances for Cmax and (VC)max were lower than those established in previous studies using full cadavers, likely a result of our removal of soft tissues from the pelves prior to impact.  相似文献   

20.
doi: 10.1111/j.1741‐2358.2012.00625.x Comparison of mandibular bone mineral density in osteoporotic, osteopenic and normal elderly edentulous subjects measured by the dual‐energy X‐ray absorptiometry technique Objective: The aim of this study was to compare the mandibular body bone mineral density according to bone mineral density status of spine and femur measured by dual‐energy X‐ray absorptiometry (DXA) technique in elderly edentulous individuals. Background: One of the factors that affect the survival rate of implants is bone mineral density (BMD) of the jaws. Materials and methods: Fifty edentulous elderly patients’ (27 women and 23 men) spine, femur and the mandibular body BMDs were measured using DXA technique. BMD scans of the AP lumbar spine (L2–L3) and femur were classified using World Health Organisation criteria for bone mass. Results: There was a statistically significant difference between the normal femur group’s–osteoporosis group’s mandibular body BMD (p = 0.001) and femoral osteopaenia group’s–osteoporosis group’s mandibular body BMD (p < 0.001). The femoral osteoporosis group’s mandibular body BMDs were lower than those of both the normal femoral and the femoral osteopaenia group subjects’. Conclusion: Classification of edentulous mandibles according to low and high bone mineral densities is a problem in implant dentistry. The results of this study demonstrated that femoral bone mineral density status may be used to provide preliminary information about the bone mineral density of the mandibular body region in elderly edentulous subjects.  相似文献   