首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Eight pyridylamino (PA) derivatives of fucose-containing oligosaccharides, which occur as free oligosaccharides in human milk and also are derived from glycosphingolipids, have been analyzed by high-performance liquid chromatography (HPLC) on normal-phase and reversed-phase columns, and by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Six out of eight PA-oligosaccharides were clearly separated by both normal- and reversed-phase HPLC at a column temperature of 40 degrees C, but two PA-oligosaccharides, lacto-N-fucopentaose II [Gal beta1-3(Fuc alpha1-4)GlcNAc beta1-3Gal beta1-4GIcPA] and lacto-N-fucopentaose III [Gal beta1-4(Fuc alpha1-3)GlcNAc beta1-3Gal beta1-4GIcPA], were not separated. The two unresolved PA-oligosaccharides were finally separated by reversed-phase HPLC at a column temperature of 11 degrees C. MALDI-TOF mass spectra of PA-oligosaccharides demonstrated pseudo-molecular ions as the predominant signals, therefore information about the molecular mass of each PA-oligosaccharide was easily obtained. Post-source decay (PSD) MALDI-TOF mass spectra of PA-oligosaccharides gave information about the carbohydrate sequences and carbohydrate species of each PA-oligosaccharide by detecting the ions responsible for the cleavage of the glycosidic bonds. The detection limits of the PA-oligosaccharides by HPLC, MALDI-TOF mass spectrometry, and PSD MALDI-TOF mass spectrometry were 20 fmol, 20 fmol, and 2 pmol, respectively. These results suggest that a system including HPLC and MALDI-TOF mass spectrometry or HPLC and PSD MALDI-TOF mass spectrometry is quite useful for the structural characterization of sub-pmol or pmol levels of fucose-containing oligosaccharides, and that these methods could be used for the analysis of various types of oligosaccharides derived from glycoproteins and glycosphingolipids.  相似文献   

2.
Pools of O-glycopeptides prepared from trypsin-digested reduced and alkylated human serum IgA1 have been analyzed using matrix-assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-ToF-MS) in the positive-ion mode, using 2,4,6-trihydroxy acetophenone-ammonium citrate matrix. Dozens of such pools prepared from normal serum IgA1 and from serum of patients with a number of different medical conditions have been routinely analyzed in this manner. The glycopeptides present in these pools possess identical amino acid sequences but are substituted with a variety of neutral and sialylated glycans and the spectra obtained were such that individual compositional glycoforms were baseline resolved. In addition, the spectra were reproducible, exhibiting a relative peak intensity and area variation of around 11-16%, enabling the technique to be used for the relative quantitation of the different compositional glycoforms present. This could be achieved manually or by applying a Java program especially developed for this purpose. The MS analysis described here is a major improvement over present MALDI methods used for profiling the O-glycosylation of IgA1. The MS methodology together with the Java data analysis are expected to be generally applicable for profiling O-linked glycopeptides derived from other glycoproteins and probably for N-linked glycopeptide pools.  相似文献   

3.
Foret F  Preisler J 《Proteomics》2002,2(4):360-372
Mass spectrometry is becoming the major analytical tool in biology research. This short review summarizes the state-of-the-art in the interface miniaturization and strategies for analysis of limited sample amounts by matrix assisted laser desorption/ionization mass spectrometry.  相似文献   

4.
Phosphoamino acid modifications on substrate proteins are critical components of protein kinase signaling pathways. Thus, diverse methodologies have been developed and applied to identify the sites of phosphorylated amino acids within proteins. Despite significant progress in the field, even the determination of phosphorylated residues in a given highly purified protein is not a matter of routine and can be difficult and time-consuming. Here we present a practicable approach that integrates into a liquid chromatography matrix-assisted laser desorption/ionization mass spectrometry (LC–MALDI MS) workflow and allows localization and quantification of phosphorylated peptides on the MALDI target plate prior to MS analysis. Tryptic digests of radiolabeled proteins are fractionated by reversed-phase LC directly onto disposable MALDI target plates, followed by autoradiographic imaging. Visualization of the radiolabel enables focused analysis of selected spots, thereby accelerating the process of phosphorylation site mapping by decreasing the number of spectra to be acquired. Moreover, absolute quantification of the phosphorylated peptides is permitted by the use of appropriate standards. Finally, the manual sample handling is minimal, and consequently the risk of adsorptive sample loss is very low. Application of the procedure allowed the targeted identification of six novel autophosphorylation sites of AMP-activated protein kinase (AMPK) and displayed additional unknown phosphorylated peptide species not amenable to detection by MS. Furthermore, autoradiography revealed topologically inhomogeneous distribution of phosphorylated peptides within individual spots. However, accurate analysis of defined areas within single spots suggests that, rather than such quantitative differences, mainly the manner of matrix crystallization significantly affects ionization of phosphopeptides.  相似文献   

5.
On-target affinity capture, enrichment and purification of biomolecules improve detection of specific analytes from complex biological samples in matrix-assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-TOF-MS) analysis. In this paper, we report a simple method for preparation of a self-assembled nitrilotriacetic acid (NTA) monolayer on gold surface which can be used as a MALDI-TOF-MS sample target specifically for recombinant oligohistidine-tagged proteins/peptides and phosphorylated peptides. The NTA functional groups are immobilized to the gold surface via the linkage of 1,8-octanedithiol which forms a self-assembled monolayer on gold. Characterization by X-ray photoelectron spectroscopy and MALDI analysis of the modified surface are described. The chemically modified surface shows strong affinity toward the analytes of interest, which allows effective removal of the common interferences, e.g. salts and detergents, and therefore leads to improved signal/noise ratio and detection limit. The use of the modified surface simplifies the sample preparation for MALDI analysis of these targeted analytes.  相似文献   

6.
基质辅助激光解吸电离飞行时间质谱对阪崎肠杆菌的鉴定   总被引:1,自引:0,他引:1  
目的 利用基质辅助激光解吸电离飞行时间质谱(MALDI-TOF-MS)法对阪崎肠杆菌进行鉴定,建立一种高效检测阪崎肠杆菌的方法,并为该技术的推广使用及阪崎肠杆菌的进一步研究提供科学依据.方法 用MALDI-TOF-MS法检测38株野生阪崎肠杆菌、2株标准菌株和1株阴沟肠杆菌,结果与常规生化鉴定结果对比;同时对在不同培养基上培养的阪崎肠杆菌进行质谱分析比较,对比不同培养基对质谱结果是否有影响;对38株野生菌株质谱图进行聚类分析.结果 38株菌株鉴定结果均为阪崎肠杆菌,与生化鉴定结果一致,且质谱鉴定分值大多在2.0以上.通过MALDI-TOF-MS鉴定方法可以很明显地将阴沟肠杆菌与阪崎肠杆菌两种菌分开.4种培养基对MALDI-TOF-MS鉴定结果的影响不是很明显,TSA比较适合作为阪崎肠杆菌MALDI-TOF-MS鉴定的培养基.通过质谱图谱和离子峰值比较得出,所有菌株在5745 m/z附近均出现高的离子峰,在2871、4740、8288、6260和9488 m/z附近出现离子峰的实验菌株达95%以上;在差异水平在0.5时,MALDI-TOF-MS的聚类分析结果可将所有实验菌株分成5个类型,结合菌株对应的来源和种类分析表明本研究所用菌株与来源和种类之间并无明显关系.结论 MALDI-TOF-MS方法具有准确且精确鉴定阪崎肠杆菌的能力;离子峰5745m/z具有作为阪崎肠杆菌的标记性离子峰的可能;差异水平为0.5进行MALDI-TOF-MS聚类分析,未发现5个类型与来源等具有一定关系,需要进一步研究.  相似文献   

7.
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) was used to investigate whole and freeze-thawed Cryptosporidium parvum oocysts. Whole oocysts revealed some mass spectral features. Reproducible patterns of spectral markers and increased sensitivity were obtained after the oocysts were lysed with a freeze-thaw procedure. Spectral-marker patterns for C. parvum were distinguishable from those obtained for Cryptosporidium muris. One spectral marker appears specific for the genus, while others appear specific at the species level. Three different C. parvum lots were investigated, and similar spectral markers were observed in each. Disinfection of the oocysts reduced and/or eliminated the patterns of spectral markers.  相似文献   

8.
Ribonuclease (RNase) B incubated with purified enzymes, whole bacterial cultures, or their separated components-cells and supernates-have been directly analyzed by matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-ToF) to detect exomannosidases and to evaluate their specificities and location. Enzymatic cleavage was monitored by observing changes in RNase B glycoform population. Thus a nonspecific alpha-(1 --> 2)-mannosidase activity converts the glycoprotein to its Man(5) form, identifiable by its mass of 14,899 [M + H](+); this species subsequently is converted, by the actions of alpha-(1 --> 3) and alpha-(1 --> 6)-mannosidases, to the Man(1) form via Man(4), Man(3), and Man(2). The Man(1) glycoform (which is readily isolated) has then similarly been used for identifying beta-(1 --> 4)-mannosidase and the derived Man(0) form has served in turn as a natural substrate for beta-(1 --> 4) N-acetylglucosaminidase producing a species possessing a single asparagine-linked GlcNAc residue (mass 13,886). Mannose liberated from the actions of mannosidases can, if desired, be quantified by, for example, chromatography. The actions and specificities of endoglycosidases such as a peptide-N-glycosidase F (PNGase F) and of endo-N-acetlyglucosaminidases (e.g., endo-F and endo-H), which respectively cleave between the GlcNAc&bond;Asn and GlcNAc&bond;GlcNAc bonds of N-linked glycoproteins, are also demonstrable by MALDI-ToF analysis of RNase B (and derived products). From these digests the completely deglycosylated polypeptide corresponding to RNase A in which Asn has been converted to Asp (mass 13,684) and a species corresponding to RNase A + GlcNAc (mass 13,886) are produced, together with their corresponding free oligosaccharides which are amenable to analysis by both MALDI-ToF and by HPLC.  相似文献   

9.
For our analysis of the data from the First Annual Proteomics Data Mining Conference, we attempted to discriminate between 24 disease spectra (group A) and 17 normal spectra (group B). First, we processed the raw spectra by (i) correcting for additive sinusoidal noise (periodic on the time scale) affecting most spectra, (ii) correcting for the overall baseline level, (iii) normalizing, (iv) recombining fractions, and (v) using variable-width windows for data reduction. Also, we identified a set of polymeric peaks (at multiples of 180.6 Da) that is present in several normal spectra (B1-B8). After data processing, we found the intensities at the following mass to charge (m/z) values to be useful discriminators: 3077, 12 886 and 74 263. Using these values, we were able to achieve an overall classification accuracy of 38/41 (92.6%). Perfect classification could be achieved by adding two additional peaks, at 2476 and 6955. We identified these values by applying a genetic algorithm to a filtered list of m/z values using Mahalanobis distance between the group means as a fitness function.  相似文献   

10.
Staphylococcus aureus is an important human pathogen frequently resistant to a wide range of antibiotics. Methicillin-resistant S. aureus (MRSA) strains are common nosocomial pathogens that pose a world-wide problem. Rapid and accurate discrimination between methicillin-sensitive S. aureus (MSSA) and methicillin-resistant S. aureus is essential for appropriate therapeutic management and timely intervention for infection control. We report here the application of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) for monitoring the bacterial fingerprints expressed by two well characterized S. aureus strains ATCC 29213 (MSSA) and ATCC 43330 (MRSA). Consistent strain-specific data were obtained from subcultures analyzed over a period of three months as well as after changing the growth media from Mueller-Hinton to blood agar indicating the reliability of the method. The bacterial fingerprints of these two strains were compared to independent clinical isolates of S. aureus. A uniform signature profile for MRSA could not be identified. However, the bacterial fingerprints obtained proved to be specific for any given strain. This study demonstrates that MALDI-TOF MS is a powerful method for rapid identification of clonal strains of S. aureus, which might be useful for tracking nosocomial outbreaks of MRSA and for epidemiologic studies of infections diseases in general.  相似文献   

11.
Class I bacteriocins (lantibiotics) and class II bacteriocins are antimicrobial peptides secreted by gram-positive bacteria. Using two lantibiotics, lacticin 481 and nisin, and the class II bacteriocin coagulin, we showed that bacteriocins can be detected without any purification from whole producer bacteria grown on plates by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF-MS). When we compared the results of MALDI-TOF-MS performed with samples of whole cells and with samples of crude supernatants of liquid cultures, the former samples led to more efficient bacteriocin detection and required less handling. Nisin and lacticin 481 were both detected from a mixture of their producer strains, but such a mixture can yield additional signals. We used this method to determine the masses of two lacticin 481 variants, which confirmed at the peptide level the effect of mutations in the corresponding structural gene.  相似文献   

12.
An effective method was developed for isolation and analysis of bovine heart complex I subunits. The method uses C18 reversed-phase high-performance liquid chromatography (HPLC) and a water/acetonitrile gradient containing 0.1% trifluoroacetic acid. Employing this system, 36 of the 45 complex I subunits elute in 28 distinct chromatographic peaks. The 9 subunits that do not elute are B14.7, MLRQ, and the 7 mitochondrial-encoded subunits. The method, with ultraviolet (UV) detection, is suitable for either analytical (<50 μg protein) or preparative (>250 μg protein) applications. Subunits eluting in each chromatographic peak were initially determined by matrix-assisted laser desorption/ionization-time-of-flight/mass spectrometry (MALDI-TOF/MS) with subsequent positive identification by reversed-phase HPLC-electrospray ionization (ESI)/tandem mass spectrometry (MS/MS) analysis of tryptic digests. In the latter case, subunits were identified with a 99% probability using Mascot for database searching and Scaffold for assessment of protein identification probabilities. The reversed-phase HPLC subunit analysis method represents a major improvement over previous separation methods with respect to resolution, simplicity, and ease of application.  相似文献   

13.
Appropriate methods for the analysis of microdissected solid tumour tissues by matrix-assisted laser desorption/ionisation-time of flight-mass spectrometry (MALDI-TOF MS) are not yet well established. Optimisation of sample preparation was performed first on undissected tissue slices, representing approximately 200 000 cells, which were solubilised either in urea containing buffer, trifluoroethanol/NH4HCO3, 0.1% sodium dodecyl sulphate (SDS) or in 0.1% RapiGest solution, then trypsin digested and analysed by MALDI-TOF MS. Solubilisation in 0.1% SDS resulted in detection of the highest number of sample specific peak signals. Interestingly, there was little overlap in detectable peaks using the different buffers, implying that they can be used complementarily to each other. Additionally, we fractionated tryptic digests on a monolithic high-performance liquid chromatography column. Fractionation of tryptic digest from whole tissue sections resulted in a four-fold increase in the total number of peaks detected. To prove this principle, we used 0.1% SDS to generate peptide patterns from 2000 microdissected tumour and stromal cells from five different breast carcinoma tumours. The tumour and stroma specific peaks could be detected upon comparison of the peptide profiles. Identification of differentially expressed peaks by MALDI-TOF/TOF MS was performed on fractionated tryptic digests derived from a whole tissue slice. In conclusion, we describe a method that is suitable for direct peptide profiling on small amounts of microdissected cells obtained from breast cancer tissues.  相似文献   

14.
In addition to protein identification, characterization of post-translational modifications (PTMs) is an essential task in proteomics. PTMs represent the major reason for the variety of protein isoforms and they can influence protein structure and function. Upon matrix-assisted laser desorption/ionization (MALDI) most post-translationally modified peptides form a fraction of labile molecular ions, which lose PTM-specific residues only after acceleration. Compared to fully accelerated ions these fragment ions are defocused and show in reflector mass spectra reduced resolution. A short time Fourier transform using a Hanning window function now uses this difference in resolution to detect the metastable fragments. Its application over the whole mass range yields frequency distributions and amplitudes as a function of mass, where an increased low frequency proportion is highly indicative for metastable fragments. Applications on the detection of metastable losses originating from carboxamidomethylated cysteines, oxidized methionines, phosphorylated and glycosylated amino acid residues are presented. The metastable loss of mercaptoacetamide detected with this procedure represents a new feature and its integration in search algorithms will improve the specificity of MALDI peptide mass fingerprinting.  相似文献   

15.
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) and ion-pair-reverse-phase high-performance liquid chromatography (IP-RP HPLC) techniques were combined to determine the sequence identity of short single-stranded deoxyoligonucleotides. This methodology is demonstrated using a commercially available multiplex set of eight primer pairs. The primer pairs were separated and collected by IP-RP HPLC. Partial sequence information for IP-RP HPLC fractions was obtained from analyzing exonuclease digestion products by MALDI-TOF MS. IP-RP HPLC, MALDI-TOF MS, exonuclease digests, and a simple computational algorithm provide an integrated strategy for determining the sequence of short nucleic acid oligomers.  相似文献   

16.
Proteomics provide potential in the discovery of new sensitive biomarkers for environmental pollution. To evaluate this potential, we have utilized ProteinChip® technology to analyze the proteomic profile of blue mussels (Mytilus edulis) from polluted marine habitats surrounding the island of Karmøy, Norway. Two different types of contamination, heavy metals and polyaromatic hydrocarbons (PAHs), were compared to a clean reference site. Differentially expressed proteins/peptides were found, which showed a specific induction or a general suppression associated with the field site of origin. By combining sets of protein markers in a tree-building algorithm, we were able to correctly classify samples from these sites with an accuracy of 90%.  相似文献   

17.
Streptococcus pneumoniae (pneumococcus [Pnc]) is a causative agent of many infectious diseases, including pneumonia, septicemia, otitis media, and conjunctivitis. There have been documented conjunctivitis outbreaks in which nontypeable (NT), nonencapsulated Pnc has been identified as the etiological agent. The use of mass spectrometry to comparatively and differentially analyze protein and peptide profiles of whole-cell microorganisms remains somewhat uncharted. In this report, we discuss a comparative proteomic analysis between NT S. pneumoniae conjunctivitis outbreak strains (cPnc) and other known typeable or NT pneumococcal and streptococcal isolates (including Pnc TIGR4 and R6, Streptococcus oralis, Streptococcus mitis, Streptococcus pseudopneumoniae, and Streptococcus pyogenes) and nonstreptococcal isolates (including Escherichia coli, Enterococcus faecalis, and Staphylococcus aureus) as controls. cPnc cells and controls were grown to mid-log phase, harvested, and subsequently treated with a 10% trifluoroacetic acid-sinapinic acid matrix mixture. Protein and peptide fragments of the whole-cell bacterial isolate-matrix combinations ranging in size from 2 to 14 kDa were evaluated by matrix-assisted laser desorption ionization-time of flight mass spectrometry. Additionally Random Forest analytical tools and dendrogramic representations (Genesis) suggested similarities and clustered the isolates into distinct clonal groups, respectively. Also, a peak list of protein and peptide masses was obtained and compared to a known Pnc protein mass library, in which a peptide common and unique to cPnc isolates was tentatively identified. Information gained from this study will lead to the identification and validation of proteins that are commonly and exclusively expressed in cPnc strains which could potentially be used as a biomarker in the rapid diagnosis of pneumococcal conjunctivitis.  相似文献   

18.
19.
A methodology for the rapid and quantitative analysis of phosphorylation sites in proteins is presented. The coupling of capillary high-performance liquid chromatography (HPLC) to electrospray ionization mass spectrometry (ESI-MS) allowed one to distinguish phosphorylation sites based on retention time and mass difference from complex peptide mixtures. The methodology was first evaluated and validated for a mixture of non-, mono-, and dityrosine-phosphorylated synthetic peptides, corresponding to the tryptic fragment 485–496 (ALGADDSYYTAR) of the human protein tyrosine kinase ZAP-70. The limits of detection for the non-, mono- and diphosphorylated peptides were about 15, 40 and 100 fmol, respectively, when using a 300 μm I.D. column. Application of the method was extended to identify phosphopeptides generated from a trypsin digest of recombinant autophosphorylated ZAP-70, in particular with respect to quantifying the status at the regulatory phosphorylation sites Tyr-492 and Tyr-493. Combination of chromatographic and on-line tandem mass spectrometry data allowed one to ascertain the identity of the detected peptides, a prerequisite to analyses in more complex biological samples. As an extension to the methodology described above, we evaluated the feasibility of interfacing capillary HPLC to matrix assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF-MS), using a micromachined piezoelectric flow-through dispenser as the interface. This enabled direct arraying of chromatographically separated components onto a target plate that was precoated with matrix for subsequent analysis by MALDI-TOF-MS without further sample handling.  相似文献   

20.
The quantization of glycated isoforms of hemoglobin has been increasingly used in clinical practice in recent years. Glycated hemoglobin is currently considered the most important measurement for long-term control of the glycemic state and it has become a reference tool for the management of diabetes. Glutathionylated hemoglobin is an increasingly clinically relevant covalent adduct of glutathione with beta chain of the globin and its concentration has been correlated with oxidative stress. We have developed an innovative technique based on linear mode matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry for quantitative analysis of hemoglobin species. This method was applied to the quantification of glycated and glutathionylated hemoglobin. A rigorous comparison was pursued to evaluate the analytical performances in quantifying glycated hemoglobin in comparison to an established high-performance liquid chromatography method. Our results indicated a complete equivalence between the two methods. The same analysis enabled the quantitative determination of the glutathionylated hemoglobin fraction. This isoform was investigated in an adult Italian population (184 individuals, 101 males and 83 females), indicating a bimodal distribution of this species. In fact 65.22% of screened individuals had glutathionylated hemoglobin levels lower than 0.50% while 34.78% had glutathionylated hemoglobin levels higher than 0.50%. A semiautomatic robotic procedure was developed for fast analysis of a large number of samples. This is the first report of a quantitative application of linear MALDI-TOF mass spectrometry for the determination of glutathionylated hemoglobin in blood samples. This method allows fast screening of this hemoglobin isoform, therefore opening the route to explore its specificity and sensitivity as a molecular biomarker.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号