首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method is presented for the quantitative estimation of the individual amino acid radioactivity in biological samples. The material is deproteinized with cold acetone, and, after acetone evaporation, is passed through a column containing 1 g of Amberlite XAD-2, then eluted with 10% ethanol. The samples are derivatized with Sanger's reagent (alkaline 1-fluoro-2,4-dinitrobenzene) and passed again through the Amberlite XAD-2 column; the 10% ethanol eluate is now discarded and the DNP-amino acids eluted with acetone. Aliquots are used for TLC chromatography on Silicagel plates; the spots are identified, cut away and their radioactivity estimated. The actual recovery of radioactivity in the spots is about 86-92% of the initial radioactivity. No contamination with radioactive glucose, lactate, pyruvate or glycerol has been observed.  相似文献   

2.
Betaine is a major metabolite of choline in liver and kidney and may be an important product of choline metabolism in other tissues. The available methods for assay of betaine, however, are time consuming and relatively insensitive. We describe a modification of published methods that provides a sensitive and specific assay for betaine by derivatization and HPLC separation with UV quantitation. Betaine and other water-soluble choline metabolites are extracted from biological samples and separated by HPLC based on mobility of 14C-labeled internal standards. The betaine fraction is collected and derivatized with 4'-bromo-phenacyl triflate. The betaine-triflate derivative is quantitated by UV absorbance and the result is corrected for possible losses due to incomplete extraction recovery and incomplete derivatization by simultaneous measurement of radioactivity from the derivatized 14C-betaine internal standard. Betaine concentrations determined with this procedure are reported for several adult and fetal rat tissues.  相似文献   

3.
A method for the measurement of specific lactate radioactivity in biological samples is presented. It is based on the following steps: (a) enzymatic conversion of lactate to pyruvate, (b) pyruvate conversion to 2,4-dinitrophenylhydrazone, (c) concentration-separation of the latter in reusable Amberlite XAD-7 polymeric adsorbent columns, and finally (d) estimation of the radioactivity thus retained compared with that of enzymatically untreated aliquots of the same samples. Specificity was ensured by the use of lactate dehydrogenase as specific recognizing agent for lactic acid. No interference from glucose, lactate, or amino acids was observed. The method presented is simple and can be applied in routine multiple estimations of lactic acid radioactivity in conjunction with the enzymatic measurement of lactate in biological samples in tracer metabolic studies.  相似文献   

4.
Glyco-7 alpha, 12 alpha-dihydroxy-5 beta-cholanic acid was tested as internal standard for high-pressure liquid chromatographic analysis of the five main glycine- and taurine-conjugated bile acids present in adult human serum and bile. When the standard is added to the samples before extraction, the recovery rate throughout the procedure is similar to that of other bile acids. For all bile acids studied, the response, relative to the internal standard, is linear at 205 nm. Baseline separation is observed between the internal standard and all other bile acids, both in artificial mixtures and extracts of biological samples. Thus, glyco-7 alpha, 12 alpha-dihydroxy-5 beta-cholanic acid is a reliable internal standard for HPLC analysis of conjugated bile acids in serum and bile.  相似文献   

5.
An electrochemical method for the quantitation of glucose oxidase in murine plasma and tissues has been developed. Instead of oxygen, this method uses benzoquinone as an artificial cosubstrate of glucose oxidase. The quantitative detection of the enzymatically produced hydroquinone by controlled-potential amperometry allows measurement of glucose oxidase concentrations in biological samples. The use of an internal standard corrects for all possible interfering effects. We demonstrated a 10-fold increase in sensitivity, as well as the ability to work in turbid media, in comparison to spectrophotometric methods.  相似文献   

6.
Variable recovery of polar compounds is a potential pitfall in the on-line extraction-reversed-phase HPLC analysis of lipoxygenase products. Therefore, the addition of a polar internal standard to biological samples, which permits the assessment of the recovery of the polar components in individual samples, appears to be essential. 19-Hydroxyprostaglandin (PG) B2 was found to be a suitable compound for this application. It was easily prepared from deproteinized human semen by base-catalyzed dehydration of 19-hydroxy-PGE2, and purified in a single step by reversed-phase HPLC. Similarly to PGB2, already used as internal in HPLC, 19-hydroxy-PGB2 has excellent chemical stability and carries a strong uv chromophore that enables detection at 280 nm. Most importantly, it is eluted just prior to the polar arachidonic acid metabolites 20-hydroxy- and 20-carboxy-leukotriene B4, 12-oxo-dodecatrienoic acid and the lipoxines A and B. The measurement of the ratio of PGB2 and 19-hydroxy-PGB2 used in combination as internal standards in HPLC analysis of lipoxygenase products, provides a simple and reliable way to assess sample to sample recovery of the polar components when using on-line extraction procedures.  相似文献   

7.
A method for the extraction and quantitative determination of both the mass and radioactivity of glycolic acid from -14C-labeled leaf tissue is described. The recoveries of both mass and radioactivity from standard [1-14C]glycolic acid solutions averaged 98 percent, and recovery of radioactivity added to plant samples as [1-14C]glycolic acid was over 90 percent after the complete procedure. The method was reliable with total samples containing as little as 130 nmol of glycolic acid. The mass of glycolic acid recovered from sunflower leaf tissue was proportional to the amount of tissue extracted. In experiments with different plant material, the amount of glycolic acid varied between 530 and 1120 nmol/dm-2 of leaf tissue. The specific radioactivity of the glycolic acid in sunflower leaf tissue during photosynthesis in -14CO(2) was never more than 20 percent of the specific radioactivity of the -14CO(2) supplied.  相似文献   

8.
Several scintillator solutions were tested for direct mixing with biological material for determination of calcium-45 radioactivity. For each system the capacity for aqueous solutions and stable calcium, the interference of various ions present in biological material, the stability of counting samples, and the possibility of quenching correction were determined. The results showed that the best capacity for aqueous acid solutions had Insta-Gel and Unisolve-1 scintillants. Tritontoluene-based scintillant showed marked unstability when mixed with biological fluids. The strongest quenching effect was produced by the yellow color of the ferric ion, which could be eliminated by complexing with the fluoride ion. For biological material of sufficiently high radioactivity the most convenient method seems to be counting the samples on filter paper in a toluene-based scintillator, especially since self-absorption in such a system can be corrected for by the channel and external standard ratio.  相似文献   

9.
Patients with glycogen storage disease type II (GSD II) typically excrete increased amounts of a glycogen-derived glucose tetrasaccharide, Glcalpha1-6Glcalpha1-4Glcalpha1-4Glc (Glc(4)), in the urine. With the advent of a new enzyme replacement therapy for GSD II, there is a need for early identification of patients with this disease and for monitoring the efficacy of treatment. Glc(4) is a good candidate biomarker for GSD II. A simple and robust method using stable isotope dilution-electrospray ionization-tandem mass spectrometry for the analysis of Glc(4) in biological samples was developed. A 13C(6)-labeled stable isotope internal standard was synthesized by transglycosylation using a recombinant alpha-amylase. Butyl 4-aminobenzoate derivatives of Glc(4) and the internal standard were analyzed using multiple reaction monitoring. This method was shown to be accurate and precise by the repeated analysis of calibrators and quality control samples in urine and plasma. There was good agreement with a high-performance liquid chromatography-UV method for urine samples, whereas there was less agreement with plasma samples. Accurate determination from dried urine spot samples was also demonstrated. This method is amenable to high-throughput analysis, a necessary prerequisite for mass screening for GSD II.  相似文献   

10.
Methods are described for the rapid separation of the major individual phospholipids and neutral lipids of tissues by thin-layer chromatography on small glass plates (75 × 75 mm), and for the specific microchemical estimation of separated lipids and for determination of fatty acid composition and radioactivity. The overall method, involving tissues extraction, thin-layer chromatographic separation and assay has been evaluated using pure standards and biological samples and gives good reproducibility and almost complete recovery of lipids.  相似文献   

11.
The use of internal-surface reversed-phase (ISRP) chromatography of unprocessed plasma samples was investigated as an alternative method of quantitation of the arterial plasma metabolite time course of [18F]N-methylspiperone. The ISRP method was directly compared to standard solid phase extraction/HPLC (SPE/HPLC) methods currently in wide use. Results indicate that: (1) the ISRP method is rapid and minimizes sample preparation; (2) recovery of radioactivity from the ISRP column is > 90%; (3) no radioactivity remains associated with chromatographically size excluded proteins and (4) the quantitative results are well correlated with conventional SPE/HPLC methods.  相似文献   

12.
A simple high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of abacavir and zidovudine (AZT) in rat plasma, amniotic fluid, fetal, and placental tissues. Extraction of abacavir, AZT, and the internal standard, azidouridine (AZDU) in amniotic fluid was carried out by protein precipitation. Extraction from plasma, fetal and placental homogenates was achieved by using a salting out technique. Chromatographic separation was performed using a C8 column (150 mm x 4.6 mm, 5 microm). The mobile phase consisted of 12% acetonitrile in 25 mM sodium phosphate buffer (adjusted to pH 7 with sodium hydroxide) for the fetus, placenta, plasma and amniotic fluid samples at a flow rate of 0.8 mL/min. The method was validated over the range from 0.05 to 50 microg/mL for both abacavir and AZT in the four biological matrices. The absolute recovery of abacavir ranged from 79 to 94%, while AZT recoveries ranged from 79 to 90% in the different biological matrices. The internal standard recovery ranged from 90 to 92%. Acceptable intra- and inter-day assay precision (<10% R.S.D.) and accuracy (<10% error) were observed over 0.05-50 microg/mL for all four matrices.  相似文献   

13.
For the sensitive and selective determination of zeranol, taleranol, α-zearalenol, β-zearalenol and zearalenone in animal urine and tissue a LC-MS/MS method has been developed. Sample preparation included extraction of meat samples and enzymatic digest of urine samples followed by solid-phase extraction with RP-18 columns for sample clean-up. Mass spectrometric determination was carried out with an atmospheric pressure chemical ionisation interface (APCI) in the multi-reaction monitoring mode (MRM). Using the negative ion mode detection limits between 0.1 and 0.5 ppb and determination limits between 0.5 and 1 ppb could be achieved. With zearalanone as internal standard, a linear range between 0.5 (1.0) and 100 ppb in urine samples (cow; pig) and between 1 and 100 ppb in meat samples (cow, calf, pig) could be established. Depending on the biological matrix and analyte standard deviations were below 8.2 %, with recovery rates between 86 and 102 % in spiked samples. The applicability of the method was demonstrated via several contaminated cow and pig urine samples.  相似文献   

14.
An automatic, luminometric assay of glucose in samples of the extracellular water space obtained by microdialysis is described. The assay involves oxidation by glucose oxidase (EC 1.1.3.4) and mutarotation of glucose by aldose mutarotase (EC 5.1.3.3.). The H2O2 formed is subsequently determined in a reaction catalyzed by horseradish peroxidase (EC 1.11.1.7) using luminol as electron donor. The assay is linear between 0.01 and 1 nmol in the cuvette. The detection limit, defined as 3 standard deviations of the reagent blank, was 0.008 mumol/liter in the cuvette. A complete oxidation of glucose is obtained within 4 min and 25 samples are automatically assayed within 75 min. Addition of microdialysate sample obtained from human adipose tissue in vivo did not interfere with the standard curves. Glucose added to microdialysate resulted in a complete recovery compared to a H2O2 standard. Analytical interference from different factors was investigated. No interference was observed up to the following concentrations: 5 mumol/liter epinephrine, 1 mumol/liter norepinephrine, 100 mumol/liter insulin, 500 mumol/liter pyruvate, 50 mmol/liter lactate, and 1 mumol/liter ascorbate. The glucose values with the present method correlated strongly (r = 0.984) with values obtained using a routine method involving glucose oxidase and peroxidase.  相似文献   

15.
Assay and specific radioactivity of products of the metabolism of propionic acid were determined by gas chromatography of the trimethylsilyl derivatives on a column coated with 3% SE 52 silicon, with a chromatograph incorporating a stream splitter and a gas fraction collector. With a temperature program rate of 2°C/min between 90 and 200°C it is possible to separate lactic acid, hydroxypropionic acid, methylmalonic acid, succinic acid, fumaric acid, malic acid, oxaloacetic acid, α-ketoglutaric acid, citric acid, and glucose on a single chromatogram. Glutaric acid is used as an internal standard. The determination of the radioactivity of each substrate which is recovered with the gas collector is made using labeled glutaric acid as a standard and not by using the volume of sample injected in the column. This determination has been used for metabolic studies with liver slices. It can be used also for studies in bacteria.  相似文献   

16.
A method for quantitative estimation of total radioactivity present in the free amino acid fraction of tissue samples has been described. Samples deproteinized with cold acetone were extracted, in acidic medium, with ethyl (peroxide free); after centrifugation, the aqueous phase was used for amino acid derivatization at 40°C for 15 h with 1-flouro-2,4-dinitrobenzene in bicarbonate-buffered medium. Aliquots of the derivatized samples were acidified and extracted twice again with ethyl ether. The combined organic phases were placed in glass scintilation vials, dried, and used for the determination of its radiactivity, corresponding to the radioactivity present in the free amino acid fraction of the sample. Deproteinized samples of rat blood plasma, as well as hen egg white and yolk were tested after addition of known quantities of 14C-labelled amino acids or glucose, for validation of the method. No glucose radioactivity was found in any of the extracted samples. All radioactivity added to the samples in the form of 14C-labelled alanine, glutamic acid, leucine and phenylalanine was quantitatively recovered in the derivatized fraction; only a fraction of arginine radioactivity was recovered.  相似文献   

17.
Existing methods to determine neferine, a bisbenzylisoquinline alkaloid, either have no internal standard or lack selectivity, or take longer time. Here an improved reverse-phase high-performance liquid chromatographic (RP-HPLC) method was established in biological samples. The extraction recovery was 90.9% for neferine at concentration level of 0.2 microg/ml and 77.7% for dauricine (the internal standard) at 5 microg/ml in dog plasma, respectively. The linear quantification range of the method was 25-2000 ng/ml in dog plasma, with linear correlation coefficients greater than 0.999. The intra-day and inter-day relative standard deviations (R.S.D.s) for neferine at 50, 200 and 1000 ng/ml levels in dog plasma fell in the range of 3.0-5.4% and 4.3-9.5%, respectively. The RP-HPLC method was successfully applied to a pharmacokinetics study, in which experimental dogs received a single dose of neferine (5 mg/kg i.v. or 10 mg/kg p.o.). The pharmacokinetic result was presented.  相似文献   

18.
A new method for estimating collagen synthesis in microwell cultures of fibroblasts is presented, 3H-Labeled-proline-collagen was purified by successive salt precipitations at acid and neutral pH in the presence of carrier collagen. Variability between replicates was less than 10% (standard deviation) and recovery of labeled collage internal standards was greater than 90%. More than 90% of recoverable radioactivity was in collagen as demonstrated by polyacrylamide gel electrophoresis and carboxymethyl cellulose chromatography. The culture system is highly reproducible and allows use of a large number of separate cultures with uniformity of culture conditions and economy of reagents.  相似文献   

19.
1. Of the glucose in rat blood 79.8+/-3.3% (s.d.) was in the plasma. The variance was mostly due to differences between rats. 2. The concentration of glucose in erythrocyte water was 51+/-8% (s.d.) of that in plasma water. 3. The ratio (specific radioactivity in plasma)/(specific radioactivity in whole blood), i.e. the P/B ratio, was estimated for glucose at intervals after intravenous injection of [U-(14)C]glucose and [U-(14)C]fructose. The ratio differed from unity by more than the standard error of a single determination of the specific radioactivity of blood or plasma glucose except from 10 to 17min. after injection of [(14)C]glucose and from 22 to 30min. after injection of [(14)C]fructose. At all other times specific radioactivities in blood had to be corrected to give specific radioactivities in plasma. How to do so is described. 4. The P/B ratios were accounted for by a turnover of glucose in erythrocytes of 0.14mumole/min./ml. of erythrocytes. 5. Metabolism of glucose in rat erythrocytes is unlikely to be a major source of lactate.  相似文献   

20.
A new method has been developed which measures directly the beam damage suffered by biological specimens in the electron microscope. This method involves the use of radioautography to measure specific radioactivity of labeled specimens, either exposed or unexposed to the beam. Using this technique, it has been found that macromolecular samples such as ribosomes and R17 virions are severely damaged during standard electron microscopic operations: from 15 to 40% of the mass of the sample may be lost in a 30 sec exposure to the beam.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号