首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Studying cell functions for cellomics studies often requires the use of purified individual cells from mixtures of various kinds of cells. We have developed a new non-destructive on-chip cell sorting system for single cell based cultivation, by exploiting the advantage of microfluidics and electrostatic force. The system consists of the following two parts: a cell sorting chip made of poly-dimethylsiloxane (PDMS) on a 0.2-mm-thick glass slide, and an image analysis system with a phase-contrast/fluorescence microscope. The unique features of our system include (i) identification of a target from sample cells is achieved by comparison of the 0.2-μm-resolution phase-contrast and fluorescence images of cells in the microchannel every 1/30 s; (ii) non-destructive sorting of target cells in a laminar flow by application of electrostatic repulsion force for removing unrequited cells from the one laminar flow to the other; (iii) the use of agar gel for electrodes in order to minimize the effect on cells by electrochemical reactions of electrodes, and (iv) pre-filter, which was fabricated within the channel for removal of dust contained in a sample solution from tissue extracts. The sorting chip is capable of continuous operation and we have purified more than ten thousand cells for cultivation without damaging them. Our design has proved to be very efficient and suitable for the routine use in cell purification experiments.  相似文献   

2.
Cell separation is important in medical and biological research and plays an increasingly important role in clinical therapy and diagnostics, such as rare cancer cell detection in blood. The immunomagnetic labeling of cells with antibodies conjugated to magnetic nanospheres gives rise to a proportional relationship between the number of magnetic nanospheres attached to the cell and the cell surface marker number. This enables the potential fractionation of cell populations by magnetophoretic mobility (MM). We exploit this feature with our apparatus, the Dipole Magnet Flow Fractionator (DMFF), which consists of an isodynamic magnetic field, an orthogonally-oriented thin ribbon of cell suspension in continuous sheath flow, and ten outlet flows. From a sample containing a 1:1 mixture of immunomagnetically labeled (label+) and unlabeled (label-) cells, we achieved an increase in enrichment of the label+ cell fraction with increasing outlet numbers in the direction of the magnetic field gradient (up to 10-fold). The total recovery of the ten outlet fractions was 90.0+/-7.7%. The mean MM of label+ cells increased with increasing outlet number by up to a factor of 2.3. The postulated proportionality between the number of attached magnetic beads and the number of cell surface markers was validated by comparison of MM measured by cell tracking velocimetry (CTV) with cell florescence intensity measured by flow cytometry.  相似文献   

3.
4.
ABSTRACT: BACKGROUND: Malaria remains a major cause of morbidity and mortality worldwide. Flow cytometry-based assays that take advantage of fluorescent protein (FP)-expressing malaria parasites have proven to be valuable tools for quantification and sorting of specific subpopulations of parasite-infected red blood cells. However, identification of rare subpopulations of parasites using green fluorescent protein (GFP) labelling is complicated by autofluorescence (AF) of red blood cells and low signal from transgenic parasites. It has been suggested that cell sorting yield could be improved by using filters that precisely match the emission spectrum of GFP. METHODS: Detection of transgenic Plasmodium falciparum parasites expressing either tdTomato or GFP was performed using a flow cytometer with interchangeable optical filters. Parasitaemia was evaluated using different optical filters and, after optimization of optics, the GFP-expressing parasites were sorted and analysed by microscopy after cytospin preparation and by imaging cytometry. RESULTS: A new approach to evaluate filter performance in flow cytometry using two-dimensional dot blot was developed. By selecting optical filters with narrow bandpass (BP) and maximum position of filter emission close to GFP maximum emission in the FL1 channel (510/20, 512/20 and 517/20; dichroics 502LP and 466LP), AF was markedly decreased and signalbackground improve dramatically. Sorting of GFP-expressing parasite populations in infected red blood cells at 90 or 95% purity with these filters resulted in 50-150% increased yield when compared to the standard filter set-up. The purity of the sorted population was confirmed using imaging cytometry and microscopy of cytospin preparations of sorted red blood cells infected with transgenic malaria parasites. DISCUSSION: Filter optimization is particularly important for applications where the FP signal and percentage of positive events are relatively low, such as analysis of parasite-infected samples with in the intention of gene-expression profiling and analysis. The approach outlined here results in substantially improved yield of GFP-expressing parasites, and requires decreased sorting time in comparison to standard methods. It is anticipated that this protocol will be useful for a wide range of applications involving rare events.  相似文献   

5.
Gräbner R  Till U  Heller R 《Cytometry》2000,40(3):238-244
BACKGROUND: Endothelial cell adhesion molecules are involved in initiation and progression of vascular diseases. The purpose of this study was to determine conditions of fixation and dissociation of human umbilical vein endothelial cell (HUVEC) monolayers that permit a reliable flow cytometric determination of intracellular and surface content of E-selectin, vascular cell adhesion molecule-1 (VCAM-1), and intercellular adhesion molecule-1 (ICAM-1). METHODS: TNFalpha-treated HUVEC monolayers were fixed with 0.5% formaldehyde at the end of the experimental incubation. Subsequently, either the monolayer was trypsinized and thereafter the cells were subjected to indirect fluorescence labeling or the monolayer was first labeled and then dissociated by trypsinization. Cell integrity was assessed by vimentin staining. Total adhesion molecule content was detected in saponin-permeabilized cells. RESULTS: HUVEC integrity was maintained when the fixation time of the monolayer did not exceed 5 min and trypsin/EDTA was used for dissociation. Surface adhesion molecules were partially hydrolyzed by trypsin when trypsinization preceded labeling but antibody binding protected adhesion molecules from degradation. VCAM-1 and E-selectin exhibited substantial trypsin-sensitive surface fractions but surface ICAM-1 was mainly trypsin resistant. Permeabilization with 0.06% saponin allowed the detection of considerable intracellular pools of the investigated adhesion molecules. CONCLUSIONS: The described method permits the reliable determination of surface and intracellular fractions of adhesion molecules in formaldehyde-fixed HUVEC monolayers and may be used for studies on the regulation of adhesion molecule expression.  相似文献   

6.
We have developed a quadrupole magnetic flow sorter (QMS) to facilitate high-throughput binary cell separation. Optimized QMS operation requires the adjustment of three flow parameters based on the immunomagnetic characteristics of the target cell sample. To overcome the inefficiency of semiempirical operation/optimization of QMS flow parameters, a theoretical model of the QMS sorting process was developed. Application of this model requires measurement of the magnetophoretic mobility distribution of the cell sample by the cell tracking velocimetry (CTV) technique developed in our laboratory. In this work, the theoretical model was experimentally tested using breast carcinoma cells (HCC1954) overexpressing the HER-2/neu gene, and peripheral blood leukocytes (PBLs). The magnetophoretic mobility distribution of immunomagnetically labeled HCC1954 cells was measured using the CTV technique, and then theoretical predictions of sorting recoveries were calculated. Mean magnetophoretic mobilities of (1-3) x 10(-4) mm(3)/(T A s) were obtained depending on the labeling conditions. Labeled HCC1954 cells were mixed with unlabeled PBLs to form a "spiked" sample to be separated by the QMS. Fractional recoveries of cells for different flow parameters were examined and compared with theoretical predictions. Experimental results showed that the theoretical model accurately predicted fractional recoveries of HCC1954 cells. High-throughput (3.29 x 10(5) cells/s) separations with high recovery (0.89) of HCC1954 cells were achieved.  相似文献   

7.
Investigations of rare cell types in peripheral blood samples, such as tumor, fetal, and endothelial cells, represent an emerging field with several potentially valuable medical applications. Peripheral blood is a particularly attractive body fluid for the detection of rare cells as its collection is minimally invasive and can be repeated throughout the course of the disease. Because the number of rare cells in mononuclear cells can be very low (1 in 10 million), a large number of cells must be quickly screened, which places demanding requirements on the screening technology. While enrichment technology has shown promise in managing metastatic disease, enrichment can cause distortions of cell morphology that limit pathological identification, and the enrichment targeting adds additional constraints that can affect sensitivity. Here, we describe a new approach for detecting rare leukemia cells that does not require prior enrichment. We have developed an immunocytochemical assay for identification of leukemia cells spiked in peripheral blood samples, and a high-speed scanning instrument with high numerical aperture and wide field of view to efficiently locate these cells in large sample sizes. A multiplex immunoassay with four biomarkers was used to uniquely identify the rare cells from leukocytes and labeling artifacts. The cytometer preserves the cell morphology and accurately locates labeled rare cells for subsequent high resolution imaging. The sensitivity and specificity of the approach show promise for detection of a low number of leukemia cells in blood (1 in 10 million nucleated cells). The method enables rapid location of rare circulating cells (25 M cells/min), no specific enrichment step, and excellent imaging of cellular morphology with multiple immunofluorescent markers. The cell imaging is comparable to other imaging approaches such as laser scan cytometry and image flow cytometry, but the cell analysis rate is many orders of magnitude faster making this approach practical for detection of rare cells.  相似文献   

8.
Positive selection of CD34+ blood progenitor cells from circulation has been reported to improve patient recovery in applications of autologous transplantation. Current magnetic separation methods rely on cell capture and release on solid supports rather than sorting from flowing suspensions, which limits the range of therapeutic applications and the process scale up. We tested CD34+ cell immunomagnetic labeling and isolation from fresh leukocyte fraction of peripheral blood (leukapheresis) using the continuous quadrupole magnetic flow sorter (QMS), consisting of a flow channel (SHOT, Greenville, IN) and a quadrupole magnet with a maximum field intensity (B(o)) of 1.42 T and a mean force field strength (S(m)) of 1.45 x 10(8) TA/m(2). Both the sample magnetophoretic mobility (m) and the inlet and outlet flow patterns highly affect the QMS performance. Seven commercial progenitor cell labeling reagent combinations were quantitatively evaluated by measuring magnetophoretic mobility of a high CD34 expression cell line, KG-1a, using the cell tracking velocimeter (CTV). The CD34 Progenitor Cell Isolation Kit (Miltenyi Biotec, Bergisch Gladbach, Germany) showed the strongest labeling of KG-1a cells and was selected for progenitor cell enrichment from 11 fresh and 11 cryopreserved clinical leukapheresis samples derived from different donors. The CD34+ cells were isolated with a purity of 60-96%, a recovery of 18-60%, an enrichment rate of 12-169, and a throughput of (1.7-9.3) x 10(4) cells/s. The results also showed a highly regular dependence of the QMS performance on the flow conditions that agreed with the theoretical predictions based on the CD34+ cell magnetophoretic mobility.  相似文献   

9.
Encapsulation of cells in agarose gel microdrops (GMDs) combined with fluorescence-activated cell sorting (FACS) has been used previously to analyze and recover specific mammalian, bacterial, and yeast cell populations. Recently, we have developed a method to enrich mixed bacterial populations for slow-growing microorganisms using the GMD Growth Assay combined with fluorochrome staining and flow cytometry. Here, we demonstrate the feasibility of using this experimental approach to detect clonogenic growth of individual bacteria within GMDs in less than 3 h and to separate subpopulations based on differential growth rates. We show that after sorting, organisms remain viable and can be propagated in culture for further analysis.  相似文献   

10.
A fractionation method applicable to different populations of cells in a suspension is reported. The separation was accomplished by subjecting the suspension to a resonant ultrasonic field and a laminar flow field propagating in orthogonal directions within a thin, rectangular chamber. Steady, laminar flow transports the cell suspension along the chamber, while the ultrasonic field causes the suspended cells to migrate to the mid-plane of the chamber at rates related to their size and physical properties. A thin flow splitter positioned near the outlet divides the effluent cell suspension into two product streams, thereby allowing cells that respond faster to the acoustic field to be separated from those cells that respond more slowly. Modeling of the trajectories of individual cells through the chamber shows that by altering the strength of the flow relative to that of the acoustic field, the desired fractionation can be controlled. Proof-of-concept experiments were performed using hybridoma cells and Lactobacillus rhamnosus cells. The two populations of cells could be effectively separated using this technique, resulting in hybridoma/Lactobacillus ratios in the left and right product streams, normalized to the feed ratio, of 6.9 +/- 1.8 and 0.39 +/- 0.01 (vol/vol), respectively. The acoustic method is fast, efficient, and could be operated continuously with a high degree of selectivity and yield and with low power consumption. (c) 2004 Wiley Periodicals, Inc.  相似文献   

11.
BACKGROUND: Induced sputum, in contrast to bronchoscopic biopsies and lavages, is an easily obtained source of biological specimens. However, obtaining abnormal exfoliated cells for detailed molecular studies is limited because respiratory epithelial cells comprise only about 1% of sputum cell populations. METHODS: We developed a multiparameter flow sorting strategy to purify epithelial cells from nonepithelial sputum cells, using anti-cytokeratin antibody AE1/AE3 to recognize human epithelial cells and DAPI to stain DNA. We excluded cells with a high degree of side-scatter, which were composed predominantly of squamous cells and contaminating macrophages. The remaining cytokeratin-positive respiratory epithelial cells were then sorted based on anti-cytokeratin (PE) vs DNA (DAPI) parameters. RESULTS: In this proof of principle study, the AE1AE3 cytokeratin/DNA flow sorting strategy enriched rare diploid respiratory epithelial cells from an average of 1.1% of cells in unsorted induced sputum samples to average purities of 42%. Thus, AE1AE3 flow-sorting results in a 38-fold enrichment of these cells. CONCLUSIONS: We report a multiparameter flow cytometric assay to detect and enrich rare respiratory epithelial cells from induced sputum samples to average purities of 42%. With further development, this methodology may be useful as part of a molecular screening approach of populations at high risk for lung cancer.  相似文献   

12.
ATP is actively released into the extracellular environment from a variety of cell types in response to mechanical stimuli. This is particularly true in bone where mechanically induced ATP release leads to immediate early gene activation to regulate bone remodelling; however there is no consensus as to which mechanical stimuli stimulate osteoblasts the most. To elucidate which specific type(s) of mechanical stimuli induce ATP release and gene activation in human osteoblasts, we performed an array of experiments using different mechanical stimuli applied to both monolayer and 3D cultures of the same osteoblast cell type, SaOS-2. ATP release from osteoblasts cultured in monolayer significantly increased in response to turbulent fluid flow, laminar fluid flow and substrate strain. No significant change in ATP release could be detected in 3D osteoblast cultures in response to cyclic or static compressive loading of osteoblast-seeded scaffolds, whilst turbulent fluid flow increased ATP release from 3D cultures of osteoblasts to a greater degree than observed in monolayer cultures. Cox-2 expression quantified using real time PCR was significantly lower in cells subjected to turbulent fluid flow whereas c-fos expression was significantly higher in cells subjected to strain. Load-induced signalling via c-fos was further investigated using a SaOS-2 c-fos luciferase reporter cell line and increased in response to substrate strain and turbulent fluid flow in both monolayer and 3D, with no significant change in response to laminar fluid flow or 3D compressive loading. The results of this study demonstrate for the first time strain-induced ATP release from osteoblasts and that turbulent fluid flow in 3D up regulates the signals required for bone remodelling.  相似文献   

13.
We show here that autocrine ligand activation of epidermal growth factor (EGF) receptor in combination with interstitial flow is critically involved in the morphogenetic response of endothelial cells to VEGF stimulation. Human umbilical vein endothelial cell (HUVEC) monolayers cultured on a collagen gel and exposed to low interstitial flow in the absence of EGF and VEGF remained viable and mitotic but exhibited little evidence of vascular morphogenesis. Addition of VEGF produced a flow-dependent morphogenetic response within 48 to 72 h, characterized by branched capillary-like structures. The response was substantially abolished by inhibitors related to the autocrine EGF receptor pathway including Galardin, AG1478, PD98059, and an EGF receptor-blocking antibody, indicating that regulation of the morphogenetic process operates via autocrine EGF receptor activation. Moreover, we observed that in our system the EGF receptor was always activated independently of the interstitial flow, and, in addition, the EGF receptor inhibitors used above reduced the phosphorylation state of the receptor, correlating with inhibition of capillary morphogenesis. Finally, 5'bromo-2'-deoxyuridine (BrdU) labeling identified dividing cells at the monolayer but not in the extending capillary-like structures. EGF pathway inhibitors Galardin and AG1478 did not reduce BrdU incorporation in the monolayer, indicating that the EGF-receptor-mediated morphogenetic behavior is mainly due to cell migration rather than proliferation. Based on these results, we propose a two-step model for in vitro capillary morphogenesis in response to VEGF stimulation with interstitial fluid flow: monolayer maintenance by mitotic activity independent of EGF receptors and a migratory response mediated by autocrine EGF receptor activation wherein cells establish capillary-like structures.  相似文献   

14.
BACKGROUND: Fluorescence-activated cell sorting (FACS) is an attractive technique for gene or protein expression studies in rare cell populations. For cell types where specific surface markers are not known, intracellular markers can be used. However, this approach is currently held to be difficult, as the required fixation and permeabilization may cause protein modification and RNA degradation. METHODS AND RESULTS: Using the rat thyroid gland as model, rare (parafollicular) and frequent (follicular) endocrine cell types were sorted based on immunostaining for intracellular calcitonin peptide and thyroglobulin protein expression. The sorted cells were compatible with Western blot analysis of proteins, immunoassay detection of calcitonin peptide hormone and RT-PCR. CONCLUSION: We developed a robust FACS protocol that allows flow sorting of rare cells from dissociated organ material, based on intracellular markers. Our FACS protocol is compatible with downstream analysis of proteins, peptides, and mRNA in the sorted cells.  相似文献   

15.
16.
[目的]建立适用于海洋微生物的流式细胞分选与高通量单细胞培养的方法,通过该方法从印度洋深海样品中分离微生物纯培养菌株.[方法]利用流式细胞仪单细胞分选功能,以前向角(FSC)和侧向角(SSC)散射光信号代替荧光信号作为分选逻辑,对深海水体和沉积物样品中微生物进行单细胞高通量分选和培养.[结果]确定了流式细胞分选的区域和...  相似文献   

17.
Vascular endothelial cells (ECs) in vivo are subject to different flow conditions due to the variation in vessel geometry. The aim of this study is to elucidate the effects of different flow conditions on EC monolayer migration into a mechanically denuded zone and their underlying mechanisms. Both laminar and disturbed flows significantly enhanced EC migration. EC migration speed was the fastest under laminar flow, which preferentially promoted directional EC migration from the upstream side of the wounded monolayer. C3 exoenzyme (a Rho inhibitor) inhibited EC migration under static and flow conditions, and markedly reduced the effects of flow on EC migration. These results indicate that flow promotes EC migration through the Rho signaling pathway. Genistein (a tyrosine kinase inhibitor) selectively retarded EC migration under disturbed flow, suggesting that tyrosine phosphorylation may play a role in EC migration under disturbed flow. This study has demonstrated that different flow patterns differentially affect EC monolayer migration into the denuded zone involving multiple mechanisms.  相似文献   

18.
In multiple myeloma, circulating "clonotypic" B cells, that express the immunoglobulin rearrangement of the malignant plasma cell clone, can be indirectly detected by PCR. Their role as potential "feeder" cells for the malignant plasma cell pool remains controversial. Here we established for the first time an approach that allows direct tracking of such clonotypic cells by labeling with patient-specific immunoglobulin ligands in 15 patients with myeloma. Fifty percent of patients showed evidence of clonotypic B cells in blood or bone marrow by PCR. Epitope-mimicking peptides from random libraries were selected on each patient's individual immunoglobulin and used as ligands to trace cells expressing the idiotypic immunoglobulin on their surface. We established a flow cytometry and immunofluorescence protocol to track clonotypic B cells and validated it in two independent monoclonal B cell systems. Using this method, we found clonotypic B cells in only one out of 15 myeloma patients. In view of the assay's validated sensitivity level of 10(-3), this surprising data suggests that the abundance of such cells has been vastly overestimated in the past and that they apparently represent a very rare population in myeloma. Our novel tracing approach may open perspectives to isolate and analyze clonotypic B cells and determine their role in myeloma pathobiology.  相似文献   

19.
A simple procedure for measuring the cells respiration without their transformation into the suspension, is suggested: seven glass slides with the cell culture of PKEV (pork, kidney, embryo, versen) are placed into the polarographic cell. Under these conditions the oxygen electrode easily records the fall of oxygen tension in the polarographic cell due to the respiration of 10(5) cells. Oxygen consumption is linear in time at the O2 concentration within the range from 480 to 200 nanoatoms per 1 ml of medium. The respiration rate is found to be enhanced by uncoupler and suppressed by the inhibitors of the electron flow chain (NaCN, antimycin A, amytal, rotenone) and mitochondrial ATPase (oligomycin and diciclohexylcarbodiimide). The above approach enables to evaluate the mitochondrial respiration of any cell monolayer keeping the cells intact.  相似文献   

20.
BACKGROUND: Duration of apoptosis, from onset to final disintegration of the cell, is often short and variable. The apoptotic index (AI), as a snapshot of a transient event of variable length, does not truly represent incidence of apoptosis in the studied cell population. We recently proposed to estimate the cumulative apoptotic index (CAI) by inducing stathmo-apoptosis. A fluorescent inhibitor of caspases (FLICA) FAM-VAD-FMK is used to arrest the process of apoptosis and thereby prevent cell disintegration. Simultaneously, the arrested/apoptotic cells become FLICA-labeled. In the present study, this approach was applied to measure kinetics of HL-60 cell entrance into apoptosis induced via cell surface death receptor or a mitochondria-initiated pathway. Materials and Methods Cultures of HL-60 cells were treated with either TNF-alpha or camptothecin (CPT) in the absence or constant presence of 10-50 microM FLICA. The CAI was measured at different time points for up to 48 h by flow cytometry. Bivariate analysis of DNA content and cell labeling with FLICA was used to correlate apoptosis with the cell-cycle position. RESULTS: Selective loss of apoptotic cells seen in HL-60 cell cultures exposed to either TNF-alpha or CPT alone was prevented in cultures containing FLICA. Addition of FLICA alone had no effect on cell viability. The percentage of FLICA-labeled cells was plotted as a function of time after addition of TNF-alpha or CPT. The rate of cell entry to apoptosis was subsequently estimated from the slopes of the stathmo-apoptotic plot. The slopes revealed that the TNF-alpha or CPT-treated cells asynchronously underwent apoptosis with a stochastic-like kinetics and at two different rates. About 50% of cells in the TNF-alpha-treated cultures underwent apoptosis during the initial 6 h at a rate of approximately 8% of cells per hour; the remaining cells were undergoing apoptosis at a rate of approximately 2.5% of cells per hour for up to 24 h. Also, about 50% of the CPT-treated cells, predominantly those in S phase of the cell cycle, underwent apoptosis within the initial 8 h of CPT exposure, at a rate of approximately 7% of cells per hour. Remaining cells were undergoing apoptosis at a rate of approximately 1% of cells per hour during up to 48 h exposure to CPT. Spontaneous apoptosis in the untreated cultures occurred at a rate of 0.2% of cells per hour. CONCLUSIONS: This approach provides a means for measuring the kinetics of cell entrance to apoptosis (caspase activation) in large populations of cells in relation to the cell-cycle position.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号