首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This paper describes a new amperometric biosensor for glucose monitoring. The biosensor is based on the activity of glucose dehydrogenase (GDH) and diaphorase (DI) co-immobilized with NAD(+) into a carbon nanotube paste (CNTP) electrode modified with an osmium functionalized polymer. This mediator was demonstrated to shuttle the electron transfer between the immobilized diaphorase and the CNTP electrode, thus, showing a good electrocatalytic activity towards NADH oxidation at potentials around +0.2V versus Ag|AgCl, where interfering reactions are less prone to occur. The biosensor exhibits a detection limit of 10 micromol L(-1), linearity up to 8 x 10(-4) mol L(-1), a sensitivity of 13.4 microA cm(-2)mmol(-1)L(-1), a good reproducibility (R.S.D. 2.1%, n=6) and a stability of about 1 week when stored dry at 4 degrees C. Finally, the proposed biosensor was applied for the determination of glucose in different samples of sweet wine and validated with a commercial spectrophotometric enzymatic kit.  相似文献   

2.
The electrochemical (EC) detection of iodide at gold, silver and platinum electrodes under similar experimental conditions was evaluated. To achieve optimal amperometric detection, the electrode sensitivity, selectivity, and stability was compared. Isocratic separation of iodide was attained by ion chromatography (IC) using an anion-exchange column with nitrate as an eluent ion (25 mM HNO(3) + 50 mM NaNO(3)). Although the Ag electrode showed the highest selectivity due to the relatively low applied potential (+0.10 V versus Ag|AgCl), it requires continuous surface polishing upon injection of standard solutions or real samples; in addition, the chromatographic peak of iodide exhibited a pronounced dip-tailing. The limit of detection (LoD) of iodide was estimated to be 3.5 microg/L (S/N=3) with an injection volume of 50 microL. Likewise, pulsed electrochemical detection at the silver electrode did not demonstrate the expected results in terms of peak shape and low detection limit. Using the same chromatographic conditions, iodide detection at the Au electrode (E(app)= +0.80 V versus Ag|AgCl) exhibited a regular peak shape accompanied by a sensitivity comparable to the silver one. Yet, upon continuous injections the signal intensity displayed a progressive lowering up to ca. 40% in 6h. Best results in terms of signal stability, peak shape and analytical response were obtained with a modified platinum electrode which allowed to achieve a LoD of 0.5 microg/L (S/N=3). The present IC-EC detection method using a modified Pt electrode (E(app)= +0.85 V versus Ag|AgCl) was successfully applied to determine low contents of iodide in human urine with solid phase extraction as pretreatment. Such a developed method correlated very well with the reference colorimetric method in urine (r=0.95273), and it is specifically suggested when the iodide content is relatively low, i.e., <20 microg/L.  相似文献   

3.
Gold nanotubular electrode ensembles were prepared by using electroless deposition of the metal within the pores of polycarbonate track-etched membranes. Mono-enzyme (GOx) and monolayer/bilayer bienzyme (GOx/HRP) bioelectrodes were prepared by immobilizing the enzymes onto gold nanotubes surfaces modified with mercaptoethylamine. Batch amperometric responses to glucose for the different bioelectrodes were determined and compared. The response of the two geometries (monolayer and bilayer) of the bienzyme electrodes was shown to vary with regard to sensitivity at detection potentials above 0V. On the contrary, at detection potentials below 0V, no noticeable influence of the configuration of the bienzyme on the response intensity was observed. The mono-enzyme (650 microAmM-1 in benzoquinone (BQ) at -0.8 V versus Ag/AgCl) and the two bienzyme bioelectrodes (+/-400 microAmM-1 in hydroquinone (H2Q) at -0.2V versus Ag/AgCl) display remarkable sensitivities compared to a classical GOx-modified gold macroelectrode (13 microAmM-1 in BQ at -0.8 V versus Ag/AgCl). A remarkable feature of the bienzyme electrodes is the possibility to detect glucose at very low applied potentials where the noise level and interferences from other electro-oxidizable compounds are minimal. Another important characteristic of the monolayer bienzyme electrode is the possible existence of a direct electronic communication between HRP and the transducer surface.  相似文献   

4.
The end-product profile of the glucose fermentation by Propionibacterium freudenreichii ET-3 changed on an electrochemical treatment, in which the culture vessel was filled with a carbon felt anode. Acetate and propionate were produced as final end products in a molar ratio of 2:3 without any electrochemical treatments at the point of the consumption of lactate as an intermediate of the glucose fermentation. The ratio was changed to 1:1 at the point of the lactate consumption by the electrochemical incubation at an electrode potential of 0.4 V versus Ag|AgCl for 100 h. During further electrochemical incubation, propionate was oxidized to acetate as a final end-product in the microbe-containing anode chamber. 1,4-Dihydroxy-2-naphthoic acid produced by P. freudenreichii ET-3 itself would receive electrons from the metabolic pathway and serve as an electron transfer mediator from the microbial cells to the electrode.  相似文献   

5.
The novel putrescine oxidase based amperometric biosensor selectively measures putrescine, which can be considered as an indicator of microbial spoilage. Putrescine oxidase (PUOX, EC 1.4.3.10) was isolated from Kocuria rosea (Micrococcus rubens) by an improved and simplified purification process. Cells were grown on brain heart infusion medium supplemented with putrescine. Cell-free extract was prepared in Tris buffer (pH 8.0) by Bead-beater. A newly elaborated step based on three-phase partitioning (TPP) was applied in the purification protocol of PUOX. The purified enzyme was immobilized on the surface of a spectroscopic graphite electrode in redox hydrogel with horseradish peroxidase, Os mediator and poly(ethylene glycol) (400) diglycidyl ether (PEGDGE) as crosslinking agent. This modified working electrode was used in wall-jet type amperometric cell together with the Ag/AgCl (0.1M KCl) reference electrode and a platinum wire as auxiliary electrode in flow injection analysis system (FIA). Hydrogel composition, pH and potential dependence were studied. Optimal working conditions were 0.45mLmin(-1) flow rate of phosphate buffer (66mM, pH 8.0) and +50mV polarizing potential vs. Ag/AgCl. The linear measuring range of the method was 0.01-0.25mM putrescine, while the detection limit was 5μM. Beer samples were investigated by the putrescine biosensor and the results were compared by those of HPLC reference method.  相似文献   

6.
A new disposable amperometric bi-enzyme sensor system for detecting phenols has been developed. The phenol sensor developed uses horseradish peroxidase modified screen-printed carbon electrodes (HRP-SPCEs) coupled with immobilized tyrosinase prepared using poly(carbamoylsulfonate) (PCS) hydrogels or a poly(vinyl alcohol) bearing styrylpyridinium groups (PVA-SbQ) matrix. Optimization of the experimental parameters has been performed with regard to buffer composition, pH, operating potential and storage stability. A co-operative reaction involving tyrosinase and HRP occurs at a potential of -50 mV versus Ag/AgCl without the requirement for addition of extraneous H(2)O(2), thus, resulting in a very simple and efficient system. Comparison of the electrode responses with the 4-aminoantipyrine standard method for phenol sample analysis indicated the feasibility of the disposable sensor system for sensitive "in-field" determination of phenols. The most sensitive system was the tyrosinase immobilized HRP-SPCE using PCS, which displayed detection limits for phenolic compounds in the lower nanomolar range e.g. 2.5 nM phenol, 10 nM catechol and 5 nM p-cresol.  相似文献   

7.
Pan D  Chen J  Nie L  Tao W  Yao S 《Analytical biochemistry》2004,324(1):115-122
Prussian blue (PB), as a good catalyst for the reduction of hydrogen peroxide, has been combined with nonconducting poly(o-aminophenol) (POAP) film to assemble glucose biosensor. Compared with PB-modified enzymatic biosensor, the biosensor based on glucose oxidase immobilized in POAP film at PB-modified electrode shows much improved stability (78% remains after 30 days) in neutral medium. Additionally, the biosensor, at an applied potential of 0.0 V, exhibits other good characteristics, such as relative low detection limit (0.01 mM), short response time (within 5s), large current density (0.28 mA/cm2), high sensitivity (24 mAM(-1)cm(-2)), and good antiinterferent ability. The apparent activation energy of enzyme-catalyzed reaction and apparent Michaelis-Menten constant are 34.2 KJmol(-1) and 10.5 mM, respectively. In addition, effects of temperature, applied potential used in the determination, pH value of the detection solution, and electroactive interferents on the amperometric response of the sensor were investigated and are discussed.  相似文献   

8.
An enzymatic biosensor was fabricated by the covalent immobilization of pyruvate oxidase (PyO) onto the nano-particle comprised poly-5,2':5',2'-terthiophene-3'-carboxylic acid, poly-TTCA (nano-CP) layers on a glassy carbon electrode (GCE) for the amperometric detection of the phosphate ions. The direct electron transfer reaction of the immobilized PyO onto the nano-CP layers was investigated and the electron transfer rate constant was determined to be 0.65 s(-1). The electrochemically prepared nano-CP lowered the oxidation potential (+0.40 V versus Ag/AgCl) of an enzymatically generated H(2)O(2) by PyO in a phosphate solution. Experimental parameters affecting the sensitivity of the biosensors, such as amounts of the cofactors, the pH, the applied potential, and the temperature were optimized. A linear response for the detection of the phosphate ion was observed between 1.0 microM and 100 microM and the detection limit was determined to be about 0.3 microM. The response time of the biosensors was about 6s. The biosensor showed good selectivity towards other interfering anions. The long-term storage stability of the phosphate biosensor was studied and the sensor was applied in a human serum sample for the phosphate ions detection.  相似文献   

9.
Xanthine oxidase (E. C. 1.2.3.2) was immobilized by adsorption on electrochemically modified graphite plate to obtain an enzyme electrode. The current of the enzyme electrode in substrate (xanthine) solutions was found to be a result of the electrooxidation of H2O2 generated in the enzyme layer. The linearity of the amperometric signal was up to a substrate concentration of 65 microM at 0.6 V (vs. Ag/AgCl). The response time was 2 minutes. The enzyme electrode preserves 80% of its initial activity after a three-week storage in air at room temperature.  相似文献   

10.
A biosensor to detect hydrogen peroxide, by coulometry, down to submicromolar concentration using a monomolecular layer of horseradish peroxidase was developed. In this device 0.3 pmol of the enzyme were covalently immobilized on the glass surface of the biosensor and the enzyme layer was characterized by atomic force microscopy and activity measurements. The glass surface bearing the peroxidase was faced to a carbon electrode in a cell of 1 microl of active volume. The polarization of the working electrode at -100 mV versus Ag/AgCl, in the presence of 1,4-hydroquinone as mediator, allowed the fast reduction of the injected hydrogen peroxide via the hydroquinone-peroxidase system. This device permitted to measure the total number of H(2)O(2) molecules present in the cell in the concentration range of 0.3-100 microM H(2)O(2), with a sensitivity of 196 nC/microM H(2)O(2), which is close to the theoretical value (193 nC/microM).  相似文献   

11.
The dominant sugar in the body fluids of many insects is not glucose, the sugar of the vertebrates, but trehalose. In a step toward a cell that would operate in insects, we describe here a trehalose electrooxidizing anode. The novel component of the anode is its engineered, trehalose oxidation catalyzing, FAD-glucose-3-dehydrogenase (G3DH). Screening for gene-sources of G3DH pointed to the G3DH of Agrobacterium tumefaciens. Sequencing of the A. tumefaciens genome revealed a 1.7 kb fragment which contained the G3DH coding gene. The fragment was isolated, cloned and expressed in E. coli strain BL-21, to yield the approximately 65 kDa his-tagged flavoenzyme, with a specific activity of approximately 2.5U/mg protein. Electrical wiring of its reaction center to a carbon electrode through a high apparent electron diffusion coefficient (5.8 x 10(-6)cm(2)/s) redox hydrogel with a -0.2V versus Ag/AgCl redox potential resulted in the trehalose electrooxidizing anode. Trehalose was electrooxidized at pH 7.2 already at -0.36 V versus Ag/AgCl. At 0 V versus Ag/AgCl the trehalose electrooxidation current density was 0.1 mA/cm(2).  相似文献   

12.
A nanobiocomposite film consisted of polypyrrole (PPy), functionalized multiwalled carbon nanotubes (cMWNTs), and glucose oxidase (GOx) were electrochemically synthesized by electrooxidation of 0.1M pyrrole in aqueous solution containing appropriate amounts of cMWNTs and GOx. Potentiostatic growth profiles indicate that the anionic cMWNTs is incorporated within the growing PPy-cMWNTs nanocomposite for maintaining its electrical neutrality. The morphology of the PPy-cMWNTs nanocomposite was characterized by scanning electron microscopy (SEM). The PPy-cMWNTs nanocomposite was deposited homogeneously onto glassy carbon electrode. The amperometric responses vary proportionately to the concentration of hydrogen peroxide at the PPy-cMWNTs nanocomposite modified electrode at an operating potential of 0.7V versus Ag/AgCl (3M). The results indicate that the electroanalytical PPy-cMWNTs-GOx nanobiocomposite film was highly sensitive and suitable for glucose biosensor based on GOx function. The GOx concentration within the PPy-cMWNTs-GOx nanobiocomposite and the film thickness are crucial for the performance of the glucose biosensor. The amperometric responses of the optimized PPy-cMWNTs-GOx glucose biosensor (1.5 mgmL(-1) GOx, 141 mCcm(-2) total charge) displayed a sensitivity of 95 nAmM(-1), a linear range up to 4mM, and a response time of about 8s.  相似文献   

13.
We prepared a new inorganic sorbent based on modified triazine (2-[4,6-bis (aminoethylamine)-1,3,5-triazine]-Silasorb; BAT-Silasorb) which binds pea seedlings amine oxidase (PSAO) very tightly without loss of its catalytic activity. This unique feature as well as the wide substrate specificity of PSAO was successfully utilised in the construction of an amperometric biosensor based on a carbon paste electrode for the fast and sensitive detection of various amines at a formal potential 0 mV versus Ag/AgCl reference electrode. The reaction layer of the biosensor is created by the direct immobilisation of PSAO at the electrode surface via affinity carrier BAT-Silasorb. Used arrangement facilitates a simple restoration of the inactive biosensor. An amperometric signal results from horseradish peroxidase catalysed reduction of H2O2, a secondary product of the oxidative deamination of amines, catalysed by PSAO. The sensor was used for the basic characterisation of 55 biogenic and synthetic amines, from numerous mono-, di- and polyamines to various hydroxy-, thio-, benzyl- and aromatic derivatives in order to establish its suitability as a postcolumn detector. Its high sensitivity to putrescine 20.0 +/- 0.64 mA l-1 per mol (636.9 +/- 2.03 mA l-1 per mol per cm2), a limit of detection of 10 nmol l-1 (determined with respect to a signal-to-noise ratio 3:1), a linear range of current response to 0.01-100 mumol l-1 concentration of substrate and good reproducibility all indicate that the sensor could be applied to future industrial and clinical analyses.  相似文献   

14.
A new implantable electrocatalytic glucose sensor for subcutaneous glucose monitoring has been fabricated by immobilizing glucose oxidase on a chemically modified carbon fiber. The sensor was inserted subcutaneously on a male spraguely rat without any incision after dipping the microsensor in the rat's serum for 3 days. The so called "stained" microsensor, operated in the amperometric mode with an applied potential of +0.23 V versus Ag|AgCl, was able to directly measure the glucose concentration upon infusion of glucose. The results obtained were encouraging, with the response time was less than 2s and the apparent Michaelis-Menten value at 5.1+/-0.5mM. The "stained" microsensor shows good stability and reproducibility with constant response spanned over 25 days. Most common interferences in glucose analysis were minimized by the outerlayer Nafion. Hematology examinations showed minimal material-tissue interaction. Use of such mechanical devices will allow a more refined understanding towards glucose control in diabetic patients as the implanted microsensor was not effected by biocompatibility failures.  相似文献   

15.
d-Amino acid oxidase (DAAO) purified from goat kidney was immobilized covalently via N-ethyl-N-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy succinimide (NHS) chemistry onto poly indole 5-carboxylic acid (Pin5-COOH)/zinc sulfide nanoparticles (ZnSNPs) hybrid film electrodeposited on surface of an Au electrode. A highly sensitive d-amino acid biosensor was constructed using this enzyme electrode as working electrode, Ag/AgCl as reference electrode, and Pt wire as auxiliary electrode connected through potentiostat. The biosensor showed optimum response within 3 s at pH 7.5 and 35 °C, when polarized at 0.15 V vs. Ag/AgCl. There was a linear relationship between biosensor response (mA) and d-alanine concentration in the range 0.001–2.0 mM. The sensitivity of the biosensor was 58.85 μA cm?2 mM?1 with a detection limit of 0.001 mM (S/N = 3). The enzyme electrode was used 120 times over a period of 2 months when stored at 4 °C. The biosensor has an advantage over earlier enzyme sensors that it has no leakage of enzyme during reuse and is unaffected by the external environment due to the protective layer of poly indole-5-carboxylic acid film. The biosensor was evaluated and employed for measurement of d-amino acid level in fruits and vegetables.  相似文献   

16.
Glucose oxidase (E. C. 1.1.3.4) was immobilized on electrochemically modified graphite to obtain an enzyme electrode. The working surface of the electrode was coated with gelatine to prevent desorption of the enzyme. In substrate (glucose) solutions the amperometric signal of the enzyme electrode was due to the electroreduction of H202 generated in the enzyme layer. The linearity of the electrode response was found up to a substrate concentration of 300 microM at a working potential of 0 mV (vs. Ag/AgCl). It was shown that the electrode did not respond to L-ascorbic and uric acid at that working potential. The response time was about 2 min. The enzyme electrode keeps about 50% of its initial activity after a one-week storage at 4 degrees C.  相似文献   

17.
An amperometric silica sol-gel film immobilized biosensor doped with acetylcholinesterase was fabricated in the laboratory finding application in organophosphate detection based on enzyme inhibition. The substrate used was acetylthiocholine chloride and thiocholine released from the enzymatic hydrolysis was electrochemically oxidized giving larger anodic current at 0.5-0.6 V (versus Ag/AgCl reference). The dependencies of the current response on pH, enzyme loading and thermal stability of the developed biosensor were evaluated. The analytical performance of enzyme electrode towards substrate and inhibitor was investigated. Oxydemeton methyl was taken as a model compound for the inhibition studies. Linear calibration for oxydemeton methyl was obtained in the range of 2-200 ppb under the optimized conditions following an incubation time of 20 min. Treatment of the inhibited enzyme with pyridine-2-aldehyde restored 92% of its original activity. The sensor stored at -20 degrees C had a good storage and operational stability retaining 85% of its original activity for 60 successive measurements.  相似文献   

18.
Liu L  Jin X  Yang S  Chen Z  Lin X 《Biosensors & bioelectronics》2007,22(12):3210-3216
The bilayer of Con A/HRP through the biospecific affinity of concanavalin A (Con A) and glycoprotein horseradish peroxidase (HRP) was prepared on the surface of an Au electrode modified by the precursor film consisted of poly(allylamine hydrochloride) poly(sodium-p-styrene-sulfonate). Atomic force microscopy and electrochemical impedance spectroscopy were adopted to monitor the uniform layer-by-layer assembly of the Con A/HRP bilayers. The amperometric measurement was based on the inhibition of reduced thiols and performed in the presence of the electron mediator hydroquinone in 0.2 M phosphate buffer of pH 6.5 at an applied potential of −0.15 V versus Ag/AgCl. Under the optimal conditions, the biosensor presented a linear response for cysteine from 0.1 to 23.5 μM, with a detection limit of 0.02 μM. The biosensor demonstrated high stability and repeatability. A series of reduced thiols were detected by this inhibition biosensor and oxidized thiols showed no effect on the current response of the biosensor.  相似文献   

19.
A new enzyme electrode for the determination of alcohols was developed by immobilizing alcohol oxidase in polvinylferrocenium matrix coated on a Pt electrode surface. The amperometric response due to the electrooxidation of enzymatically generated H(2)O(2) was measured at a constant potential of +0.70 V versus SCE. The effects of substrate, buffer and enzyme concentrations, pH and temperature on the response of the electrode were investigated. The optimum pH was found to be pH 8.0 at 30 degrees C. The steady-state current of this enzyme electrode was reproducible within +/-5.0% of the relative error. The sensitivity of the enzyme electrode decreased in the following order: methanol>ethanol>n-butanol>benzyl alcohol. The linear response was observed up to 3.7 mM for methanol, 3.0 mM for ethanol, 6.2 mM for n-butanol, and 5.2 mM for benzyl alcohol. The apparent Michaelis-Menten constant (K(Mapp)) value and the activation energy, E(a), of this immobilized enzyme system were found to be 5.78 mM and 38.07 kJ/mol for methanol, respectively.  相似文献   

20.
Multi-walled carbon nanotubes (MWCNTs) were synthesized on platinum plate electrodes by the chemical vapor deposition (CVD) method. From the results of X-ray photoelectron spectroscopy and voltammetric investigation, the iron nanoparticles used as a catalyst for the MWCNT synthesis were enclosed with MWCNTs. The MWCNTs synthesized on the Pt plate (MWCNTs/Pt) electrode were immediately immersed into solutions of d-fructose dehydrogenase (FDH) to immobilize the enzyme onto the MWCNTs/Pt electrode surfaces. After the FDH was immobilized onto the MWCNTs/Pt electrode, a well-defined catalytic oxidation current based on FDH was observed from ca. -0.15V (versus Ag/AgCl/sat'd KCl), which was close to the redox potential of heme c as a prosthetic group of FDH. From an analysis of a plot of the catalytic current versus substrate, the calibration range for the fructose concentration was up to ca. 40mmoldm(-3), and the apparent Michaelis-Menten constant was evaluated to be 11+/-1mmoldm(-3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号