首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The measurement of intracellular calcium response transients in living mammalian cells is a popular functional assay for identification of agonists and antagonists to receptors or channels of pharmacological interest. In recent years, advances in fluorescence-based detection techniques and automation technologies have facilitated the adaptation of this assay to 384-well microplate format high-throughput screening (HTS) assays. However, the cost and time required performing the intracellular calcium HTS assays in the 384-well format can be prohibitive for HTS campaigns of greater than 1 x 10(6) wells. For these reasons, it is attractive to miniaturize intracellular calcium functional assays to the 1536-well microplate format, where assay volumes and plate throughput can be decreased by several fold. The focus of the research described in this article is the miniaturization of an intracellular calcium assay to 1536-well plate format. This was accomplished by modifying the hardware and software of a fluorometric imaging plate reader (FLIPR) to enable transfer of nanoliters of test compound directly to a 1536-well assay plate, and measure the resulting calcium response from all 1536 wells simultaneously. An intracellular calcium functional assay against the rat muscarinic acetylcholine receptor subtype 1 (rmAchR1) G-protein coupled receptor (GPCR) was miniaturized and executed on this modified instrument. In experiments measuring the activity of known muscarinic receptor agonists and antagonists, the miniaturized FLIPR assay gave EC(50) and IC(50) values and rank order potency comparable to the 384-well format assays. Calculated Z' factors for the miniaturized agonist and antagonist assays were, respectively, 0.56 +/- 0.21 and 0.53 +/- 0.22, which were slightly higher (Z'(agonist) = 0.55 +/- 0.33) and lower (Z'(antagonist) = 0.70 +/- 0.18) than the corresponding values in the 384-well assays. A mock agonist HTS campaign against the muscarinic receptor in miniaturized format was able to identify all wells spiked with the rmAchR1 agonist carbachol.  相似文献   

2.
New developments in detection technologies are providing a variety of biomolecular screening strategies from which to choose. Consequently, we performed a detailed analysis of both separation-based and non-separation-based formats for screening nuclear receptor ligands. In this study, time-resolved fluorescence resonance energy transfer (TR-FRET), ALPHAScreen, and time-resolved fluorescence (TRF) assays were optimized and compared with respect to sensitivity, reproducibility, and miniaturization capability. The results showed that the ALPHAScreen system had the best sensitivity and dynamic range. The TRF assay was more time consuming because of the number of wash steps necessary. The TR-FRET assay had less interwell variation, most likely because of ratiometric measurement. Both the ALPHAScreen and the TR-FRET assays were miniaturized to 8-microl volumes. Of the photomultiplier tube-based readers, the ALPHAScreen reader (ALPHAQuest) presented the advantage of faster reading times through simultaneous reading with four photomultiplier tubes.  相似文献   

3.
The no-wash calcium assay kits developed by Molecular Devices Corporation have greatly enhanced the throughput of cell-based calcium mobilization high-throughput screening (HTS) assays and enabled screening using nonadherent cells. The fluorescent imaging plate reader (FLIPR) Calcium 3 Assay Kit, optimal for targets that have proteins or peptides as agonists, has 2 potential drawbacks: 1) a significant downward spike in fluorescence signal upon liquid transfer that can be the same magnitude as the agonist response, making data analysis difficult; and 2) medium removal is required for some targets, which essentially reintroduces a wash step. Several no-wash products were introduced in 2005. The authors compare the Fluo-4 NW Calcium Assay Kit and the BD Calcium Assay Kit with the FLIPR Calcium 3 Assay Kit using human native rhabdomyosarcoma cells expressing the urotensin-II receptor (UT). The BDtrade mark Calcium Assay Kit gives the best performance in the true no-wash mode, in which both agonist and antagonist activity are easily quantified. Although these new products provide additional options for measuring calcium mobilization, the different results observed with each kit, using the UT receptor as an example, suggest that one should characterize all dyes against each target in a systematic way prior to choosing one for HTS.  相似文献   

4.
Fluorescence assay technologies used for miniaturized high throughput screening are broadly divided into two classes. Macroscopic fluorescence techniques (encompassing conventional fluorescence intensity, anisotropy [also often referred to as fluorescence polarization] and energy transfer) monitor the assay volume- and time-averaged fluorescence output from the ensemble of emitting fluorophores. In contrast, single-molecule detection (SMD) techniques and related approaches, such as fluorescence correlation spectroscopy (FCS), stochastically sample the fluorescence properties of individual constituent molecules and only then average many such detection events to define the properties of the assay system as a whole. Analysis of single molecular events is accomplished using confocal optics with an illumination/detection volume of approximately 1 fl (10(-15) L) such that the signal is insensitive to miniaturization of HTS assays to 1 μl or below. In this report we demonstrate the general applicability of one SMD technique (FCS) to assay configuration for target classes typically encountered in HTS and confirm the equivalence of the rate/equilibrium constants determined by FCS and by macroscopic techniques. Advantages and limitations of the current FCS technology, as applied here, and potential solutions, particularly involving alternative SMD detection techniques, are also discussed.  相似文献   

5.
A variety of functional assays are available for agonist or antagonist screening of G protein-coupled receptors (GPCRs), but it is a priori not predictable which assay is the most suitable to identify agonists or antagonists of GPCRs with therapeutic value in humans. More specifically, it is not known how a given set of GPCR agonists compares in different functional assays with respect to potency and efficacy and whether the level of the signaling cascade that is analyzed has any impact on the detection of agonistic responses. To address this question, the authors used the recently cloned human S1P(5) receptor as a model and compared a set of 3 lipid ligands (sphingosine 1-phosphate [S1P], dihydro sphingosine 1-phosphate [dhS1P], and sphingosine) in 5 different functional assays: GTPgammaS binding, inhibition of adenylyl cyclase activity, mobilization of intracellular Ca(2+) via the FLIPR and aequorin technology, and MAP kinase (ERK1/2) activation. S1P induced agonistic responses in all except the ERK1/2 assays with EC(50) values varying by a factor of 10. Whereas dhS1P was identified as a partial agonist in the GTPgammaS assay, it behaved as a full agonist in all other settings. Sphingosine displayed partial agonistic activity exclusively in GTPgammaS binding assays. The findings suggest that assays in a given cellular background may vary significantly with respect to suitability for agonist finding and that ligands producing a response may not readily be detectable in all agonist assays.  相似文献   

6.
A major focus in the current discovery of drugs targeting nuclear receptors (NRs) is identifying drugs with reduced side effects by improving selectivity, not only from other receptors but also by selective modulation of the NR of interest. Cellular assays not only provide valuable information on functional activity, potency, and selectivity but also are ideally suited for differentiating partial agonists and antagonists. The ability to partially activate a receptor is believed to be closely tied to the ability to selectively modulate the NR, resulting in expression of a subset of the normally regulated genes. To this end, the authors have built a complete panel of cell-based steroid hormone receptor assays for the androgen receptor, estrogen receptor alpha, estrogen receptor beta, glucocorticoid receptor, mineralocorticoid receptor, and progesterone receptor by stably engineering a Gal4 DNA-binding domain/nuclear receptor ligand-binding domain fusion protein into an upstream activation sequence beta-lactamase reporter cell line. Each assay was validated with known agonists and antagonists for correct pharmacology and high-throughput compatibility. To demonstrate the utility of these assays, the authors profiled 35 pharmacologically relevant compounds in a dose-response format against the panel in both agonist and antagonist modes. The results demonstrated that selective estrogen receptor modulators can be identified and differentiated, as well as mixed and partial agonists and antagonists easily detected in the appropriate assays. Importantly, a comparison of the chimeric assays with full-length reporter gene assay data from the literature shows a good degree of correlation in terms of selectivity and pharmacology of important ligands. Taken together, these steroid hormone receptor assays provide good selectivity, sensitivity, and appropriate pharmacology for high-throughput screening and selectivity profiling of modulators of steroid hormone receptors.  相似文献   

7.
We identified small molecule NTS1R agonist compounds through virtual screening of the corporate database using a ROCS approach that searches multi-conformer representations efficiently. As a starting point for the ROCS search, we used the known NTS1R selective antagonist, SR-48527, based on the hypothesis that NT agonists and antagonists might share similar binding regions. Conformations were expanded and selected as database search queries based on a cluster analysis. The search provided us with virtual hits that were tested in intracellular calcium mobilization assays of NTS1R agonist and antagonist activities measured in FLIPR format as well as in [(3)H]NT competition binding studies. The results indicated that two initial hits produced partial agonist activity with potency in the moderate micromolar range.  相似文献   

8.
Fluorescence polarization (FP) is an established technique for the study of biological interactions and is frequently used in the high-throughput screening (HTS) of potential new drug targets. This work describes the miniaturization of FP receptor assays to 1536-well formats for use in HTS. The FP assays were initially developed in 384-well microplates using CyDye-labeled nonpeptide and peptide ligands. Receptor expression levels varied from approximately 1 to 10 pmols receptor per mg protein, and ligand concentrations were in the 0.5- to 1.0-nM range. The FP assays were successfully miniaturized to 1536-well formats using Cy3B-labeled ligands, significantly reducing reagent consumption, particularly the receptor source, without compromising assay reliability. Z' factor values determined for the FP receptor assays in both 384- and 1536-well formats were found to be > 0.5, indicating the assays to be robust, reliable, and suitable for HTS purposes.  相似文献   

9.
10.
Reducing costs while maintaining the highest readout quality is a precept of modern high-throughput screening. Given the trend toward nonradiometric screening platforms, this has been a big challenge for some kinase target classes. Common issues include low sensitivity, susceptibility to nonspecific interference, or the need for costly reagents. In this study, the authors describe the feasibility of miniaturization of a serine kinase assay using generic reagents in the AlphaScreen format. They have validated the robustness of this assay in the course of miniaturization from a 35-to 4.375-microL final assay volume in 384-and 1536-well formats. Within this volume range, they consistently obtained Z' values above 0.5 and have investigated the suitability of these assay formats for measuring compound effects by testing a set of 25 previously identified active compounds. These active compounds were also reliably identified in the miniaturized assay formats. The results presented here show that the AlphaScreen technology permits robust and cost-efficient miniaturization of serine/threonine kinase assays.  相似文献   

11.
This protocol describes assay development, validation and implementation of automated immobilized metal affinity for phosphochemicals (IMAP)-based fluorescence polarization (FP) and time-resolved fluorescence resonance energy transfer (TR-FRET) high-throughput screening (HTS) assays for identification of low-molecular-weight kinase inhibitors. Both procedures are performed in miniaturized kinase reaction volumes and involve the stepwise addition of test or control compounds, enzyme and substrate/ATP. Kinase reactions are stopped by subsequent addition of IMAP-binding buffer. Assay attributes of the IMAP FP and TR-FRET methodologies are described. HTS assays developed using these procedures should result in Z-factors and low assay variability necessary for robust HTS assays. Providing that the required reagents and equipment are available, one scientist should be able to develop a 384-well, miniaturized HTS assay in approximately 6-8 weeks. Specific automated HTS assay conditions will determine the number of assay plates processed in a screening session, but two scientists should expect to process between 100 and 150 assay plates in one 8-h screening day.  相似文献   

12.
13.
This report describes the development, optimization, and implementation of a miniaturized cell-based assay for the identification of small-molecule insulin mimetics and potentiators. Cell-based assays are attractive formats for compound screening because they present the molecular targets in their cellular environment. A fluorescence resonance energy transfer (FRET) cell-based assay that measures the insulin-dependent colocalization of Akt2 fused with either cyan fluorescent protein or yellow fluorescent protein to the cellular membrane was developed. This ratiometric FRET assay was miniaturized into a robust, yet sensitive 3456-well nanoplate assay with Z' factors of approximately 0.6 despite a very small assay window (less than twofold full activation with insulin). The FRET assay was used for primary screening of a large compound collection for insulin-receptor agonists and potentiators. To prioritize compounds for further development, primary hits were tested in two additional assays, a biochemical time-resolved fluorescence resonance energy transfer assay to measure insulin-receptor phosphorylation and a translocation-based imaging assay. Results from the three assays were combined to yield 11 compounds as potential leads for the development of insulin mimetics or potentiators.  相似文献   

14.
The rapid increase in size of compound libraries, as well as new targets emerging from the Human Genome Project, require progress in ultra-high-throughput screening (uHTS) systems. In a joint effort with scientists and engineers from the biotech and the pharmaceutical industry, a modular, fully integrated system for miniaturized uHTS was developed. The goal was to achieve high data quality in small assay volumes (1-4 microL) combined with reliable and unattended operation. Two new confocal fluorescence readers have been designed. One of the instruments is a 4-channel confocal fluorescence reader, measuring with 4 objectives in parallel. The fluorescence readout is based on single-molecule detection methods, allowing high sensitivity at low tracer concentrations and delivering an information-rich output. The other instrument is a confocal fluorescence imaging reader, where the images are analyzed in terms of generic patterns and quantified in units of intensity per pixel. Both readers are spanning the application range from assays with isolated targets in homogenous solution or membrane vesicle-based assays (4-channel reader) to cell-based assays (imaging reader). Results from a comprehensive test on these assay types demonstrate the high quality and robustness of this screening system.  相似文献   

15.
Results of a complete survey of the more than 2-million-member Pharmacopeia compound collection in a 1536-well microvolume screening assay format are reported. A complete technology platform, enabling the performance of ultra-high throughput screening in a miniaturized 1536-well assay format, has been assembled and utilized. The platform consists of tools for performing microvolume assays, including assay plates, liquid handlers, optical imagers, and data management software. A fluorogenic screening assay for inhibition of a protease enzyme target was designed and developed using this platform. The assay was used to perform a survey screen of the Pharmacopeia compound collection for active inhibitors of the target enzyme. The results from the survey demonstrate the successful implementation of the ultra-high throughout platform for routine screening purposes. Performance of the assay in the miniaturized format is equivalent to that of a standard 96-well assay, showing the same dependence on kinetic parameters and ability to measure enzyme inhibition. The survey screen identified an active class of compounds within the Pharmacopeia compound collection. These results were confirmed using a standard 96-well assay.  相似文献   

16.
This article discusses the development of homogeneous, miniaturized assays for the identification of novel kinase inhibitors from very large compound collections. In particular, the suitability of time-resolved fluorescence resonance energy transfer (TR-RET) based on phospho-specific antibodies, an antibody-independent fluorescence polarization (FP) approach using metal-coated beads (IMAP technology), and the determination of adenosine triphosphate consumption through chemiluminescence is evaluated. These readouts are compared with regard to assay sensitivity, compound interference, reagent consumption, and performance in a 1536-well format, and practical considerations for their application in primary screening or in the identification of kinase substrates are discussed. All of the tested technologies were found to be suitable for miniaturized high-throughput screening (HTS) in principle, but each of them has distinct limitations and advantages. Therefore, the target-specific selection of the most appropriate readout technology is recommended to ensure maximal relevance of HTS campaigns.  相似文献   

17.
18.
Fluorescence spectroscopic studies are powerful tools for the evaluation of receptor structure and the dynamic changes associated with receptor activation. Here, we have developed two chemically distinct fluorescent probes of the cholecystokinin (CCK) receptor by attaching acrylodan or a nitrobenzoxadiazole moiety to the amino terminus of a partial agonist CCK analogue. These two probes were able to bind to the CCK receptor specifically and with high affinity, and were able to elicit only submaximal intracellular calcium responses typical of partial agonists. The fluorescence characteristics of these probes were compared with those previously reported for structurally-related full agonist and antagonist probes. Like the previous probes, the partial agonist probes exhibited longer fluorescence lifetimes and increased anisotropy when bound to the receptor than when free in solution. The receptor-bound probes were not easily quenched by potassium iodide, suggesting that the fluorophores were protected from the extracellular aqueous milieu. The fluorescence characteristics of the partial agonist probes were quite similar to those of the analogous full agonist probes and quite distinct from the analogous antagonist probes. These data suggest that the partially activated conformational state of this receptor is more closely related to its fully active state than to its inactive state.  相似文献   

19.
Two major plasma proteins in humans are primarily responsible for drug binding, the α1-acid-glycoprotein (AGP) and human serum albumin (HSA). The availability of at least a semiquantitative high-throughput assay for assessment of protein binding is expected to aid in bridging the current gap between high-throughput screening and early lead discovery, where cell-based and biochemical assays are deployed routinely to test up to several million compounds rapidly, as opposed to the late-stage candidate drug profiling methods which test at most dozens of compounds at a time. Here, we describe the miniaturization of a pair of assays based on the binding- and displacement-induced changes in fluorescence polarization (FP) of fluorescent small molecule probes known to specifically target the drug-binding sites of these two proteins. A robust and reproducible assay performance was achieved in ≤4 µL assay volume in 1,536-well format. The assays were tested against a validation set of 10 known protein binders, and the results compared favorably with data obtained using protein-coated beads with high-performance liquid chromatography analysis. The miniaturized assays were taken to a high-throughput level in a screen of the LOPAC1280 collection of 1,280 pharmacologically active compounds. The adaptation of the AGP and HSA FP assays to a 1,536-well format should allow their use in early-stage profiling of large-size compound sets.  相似文献   

20.
Cholecystokinin (CCK) is a gastrointestinal hormone, which regulates many physiological functions such as satiety by binding to the CCK receptor (CCKR). Molecules, which recognize this receptor can mimic or block CCK signaling and thereby influence CCKR-mediated processes. We have set up a quantitative heterologous assay with CHO cells over-expressing the rat CCK1 receptor to screen for such candidate molecules. Receptor activation, induced by agonist binding, is followed by an intracellular calcium increase, which was monitored using a fluorescent sensor dye. For quantification of the calcium increase, a population average technique using a fluorescence plate reader was optimized and subsequently compared with a single-cell approach using confocal microscopy. With both strategies, dose-response curves were generated for the natural agonist CCK-8S, the partial agonist JMV-180 as well as the antagonist lorglumide. Significant differences were found between the ligands and a strong correspondence was observed between both methods in terms of maximum response and median effect concentrations. Both highly sensitive methods proved complementary: whereas the plate reader assay allowed faster, high throughput screening, the confocal microscopy identified single-cell variations and revealed factors that reduce specificity and sensitivity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号