首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
Injured coliforms in drinking water   总被引:10,自引:0,他引:10  
Coliforms were enumerated by using m-Endo agar LES and m-T7 agar in 102 routine samples of drinking water from three New England community water systems to investigate the occurrence and significance of injured coliforms. Samples included water collected immediately after conventional treatment, during the backwash cycle, at various points in the distribution system, and 1 week after the break and subsequent repair of a distribution main. Injured coliforms in these samples averaged greater than 95%. m-T7 agar yielded 8- to 38-fold more coliforms than did m-Endo agar LES. The geometric mean of coliforms recovered by m-Endo agar LES was less than 1 confirmed coliform per 100 ml, although m-T7 agar yielded 5.7 to 67.5 confirmed coliforms per 100 ml. In addition, the majority of these samples giving positive results on m-T7 agar produced no detectable counts on m-Endo agar LES. These findings indicated that coliforms were injured and largely undetected by use of accepted analytical media in the systems examined.  相似文献   

2.
A new membrane filter medium was developed for the improved recovery of injured coliforms from drinking water. The new medium, termed m-T7, consists of 5.0 g of Difco Proteose Peptone no. 3, 20 g of lactose, 3.0 g of yeast extract, 0.4 ml of Tergitol 7 (25% solution), 5.0 g of polyoxyethylene ether W-1, 0.1 g of bromthymol blue, 0.1 g of bromcresol purple, and 15 g of agar per liter of distilled water. Additional selectivity may be obtained by aseptically adding 0.1 microgram of penicillin G per ml to the medium after autoclaving. In laboratory studies, m-T7 agar recovered 86 to 99% more laboratory-injured coliforms than did m-Endo agar. m-T7 agar also recovered an average of 43% more verified coliforms from 67 surface and drinking water samples than did the standard m-Endo membrane filter technique. From drinking water, m-T7 agar recovered nearly three times more coliforms than did m-Endo agar. Less than 0.5% of the colonies on m-T7 agar gave false-negative reactions, whereas greater than 70% of the typical yellow colonies from m-T7 agar produced gas in lauryl tryptose broth. Most of the verified coliforms isolated on m-T7 agar belonged to one of the four common coliform genera: Escherichia, 17.6%; Klebsiella, 21.7%; Citrobacter, 17.3%; Enterobacter, 32.2%. The results demonstrate that m-T7 agar is superior to m-Endo agar, especially for the isolation of injured coliforms from drinking water.  相似文献   

3.
Enumeration of Enterobacter cloacae after chloramine exposure.   总被引:2,自引:2,他引:0       下载免费PDF全文
Growth of Enterobacter cloacae on various media was compared after disinfection. This was done to examine the effects of monochloramine and chlorine on the enumeration of coliforms. The media used were TLY (nonselective; 5.5% tryptic soy broth, 0.3% yeast extract, 1.0% lactose, and 1.5% Bacto-Agar), m-T7 (selective; developed to recover injured coliforms), m-Endo (selective; contains sodium sulfite), TLYS (TLY with sodium sulfite), and m-T7S (m-T7 with sodium sulfite). Sodium sulfite in any medium improved the recovery of chloramine-treated E. cloacae. However, sodium sulfite in TLYS and m-T7S did not significantly improve the detection of chlorine-treated E. cloacae, and m-Endo was the least effective medium for recovering chlorinated bacteria. Differences in recovery of chlorine- and chloramine-treated E. cloacae are consistent with mechanistic differences between the disinfectants.  相似文献   

4.
Growth of Enterobacter cloacae on various media was compared after disinfection. This was done to examine the effects of monochloramine and chlorine on the enumeration of coliforms. The media used were TLY (nonselective; 5.5% tryptic soy broth, 0.3% yeast extract, 1.0% lactose, and 1.5% Bacto-Agar), m-T7 (selective; developed to recover injured coliforms), m-Endo (selective; contains sodium sulfite), TLYS (TLY with sodium sulfite), and m-T7S (m-T7 with sodium sulfite). Sodium sulfite in any medium improved the recovery of chloramine-treated E. cloacae. However, sodium sulfite in TLYS and m-T7S did not significantly improve the detection of chlorine-treated E. cloacae, and m-Endo was the least effective medium for recovering chlorinated bacteria. Differences in recovery of chlorine- and chloramine-treated E. cloacae are consistent with mechanistic differences between the disinfectants.  相似文献   

5.
A new medium, mX-Gal, has been developed for the membrane filter enumeration of beta-galactosidase-positive bacteria in municipal water supplies. mX-Gal medium contains the chromogenic beta-galactosidase substrate 5-bromo-4-chloro-3-indolyl-beta-D-galactopyranoside (X-Gal). All Aeromonas, Citrobacter, and Enterobacter strains isolated from raw water on mX-Gal medium were beta-galactosidase positive. In contrast, only 10 to 20% of these strains produced a red colony with a metallic sheen on m-Endo agar LES medium. Of 674 chlorinated water samples analyzed for total coliforms on m-Endo agar LES medium and for beta-galactosidase-positive bacteria on mX-Gal medium, 18 that were negative for coliforms on m-Endo agar LES showed beta-galactosidase-positive bacteria on mX-Gal. Of a total of 50 beta-galactosidase-positive bacteria isolated from these samples, 76% were identified as Aeromonas hydrophila.  相似文献   

6.
Total coliform counts obtained by means of standard membrane filtration techniques, using MacConkey agar, m-Endo LES agar, Teepol agar, and pads saturated with Teepol broth as growth media, were compared. Various combinations of these media were used in tests on 490 samples of river water and city wastewater after different stages of conventional purification and reclamation processes including lime treatment, and filtration, active carbon treatment, ozonation, and chlorination. Endo agar yielded the highest average counts for all these samples. Teepol agar generally had higher counts then Teepol broth, whereas MacConkey agar had the lowest average counts. Identification of 871 positive isolates showed that Aeromonas hydrophila was the species most commonly detected. Species of Escherichia, Citrobacter, Klebsiella, and Enterobacter represented 55% of isolates which conformed to the definition of total coliforms on Endo agar, 54% on Teepol agar, and 45% on MacConkey agar. Selection for species on the media differed considerably. Evaluation of these data and literature on alternative tests, including most probable number methods, indicated that the technique of choice for routine analysis of total coliform bacteria in drinking water is membrane filtration using m-Endo LES agar as growth medium without enrichment procedures or a cytochrome oxidase restriction.  相似文献   

7.
Total coliform counts obtained by means of standard membrane filtration techniques, using MacConkey agar, m-Endo LES agar, Teepol agar, and pads saturated with Teepol broth as growth media, were compared. Various combinations of these media were used in tests on 490 samples of river water and city wastewater after different stages of conventional purification and reclamation processes including lime treatment, and filtration, active carbon treatment, ozonation, and chlorination. Endo agar yielded the highest average counts for all these samples. Teepol agar generally had higher counts then Teepol broth, whereas MacConkey agar had the lowest average counts. Identification of 871 positive isolates showed that Aeromonas hydrophila was the species most commonly detected. Species of Escherichia, Citrobacter, Klebsiella, and Enterobacter represented 55% of isolates which conformed to the definition of total coliforms on Endo agar, 54% on Teepol agar, and 45% on MacConkey agar. Selection for species on the media differed considerably. Evaluation of these data and literature on alternative tests, including most probable number methods, indicated that the technique of choice for routine analysis of total coliform bacteria in drinking water is membrane filtration using m-Endo LES agar as growth medium without enrichment procedures or a cytochrome oxidase restriction.  相似文献   

8.
The following studies were done in response to questions regarding the adoption and use of the membrane filter (MF) technique for testing drinking water for the total coliform indicator group. A comparison with the most-probable-number technique showed that MF procedures with m-Endo agar LES were somewhat superior to the most-probable-number methods in terms of numbers of coliform organims recovered. Medium preparation and storage studies indicated that rehydration of m-Endo agar LES should be done with boiling water for less than 15 min, that m-Endo agar LES should not be exposed to light for more than 4 to 6 h, and that m-Endo agar LES plates may be used for up to 4 weeks and broth verification media for up to 3 weeks under given storage conditions. MF culture colonies were commonly found which did not produce sheen as expected for coliforms and yet were verified as coliforms. The occurrence and morphology of these atypical colonies were studied. Parallel inoculation of both lauryl tryptose (LT) and brilliant green bile (BGB) broth was found to be a better colony verification approach than recommended LT preenrichment before transfer to BGB. Comparison of parallel verification results indicated very little justification for the use of LT medium in MF verification procedures. In the case of overgrown or confluent cultures, the best coliform recoveries resulted from swabbing the MF plate and directly inoculating BGB medium with the swab. The occurrence of overgrowth was defined and evidence was collected suggesting that overgrowth is a function of sample holding time. Evaluation of routine test data and bacterial population reductions as a function of time indicated that nonquantitative recovery of coliforms may not be significantly affected for at least a 72-h sample holding time.  相似文献   

9.
Evaluation of m-T7 agar as a fecal coliform medium.   总被引:2,自引:2,他引:0       下载免费PDF全文
m-T7 agar, designed to improve recoveries of injured total coliforms, was evaluated for its effectiveness as a fecal coliform medium. The time and temperature of preincubation were found to be crucial to the optimal recovery of fetal coliforms. Isolation rates for fecal coliforms on m-T7 agar from sewage effluents were the highest when plates were preincubated at 37 degrees C for 8 h before transfer to 44.5 degrees C for 12 h. The medium was found to produce consistently higher fecal coliform counts than all the other methods tested. Recoveries were 3.1 times greater than the standard m-FC method and 1.7 times greater than the two-layer enrichment, temperature acclimation procedure. Verification rates for fecal coliforms isolated on m-T7 agar averaged 89.0%, whereas verification rates for m-FC agar averaged only 82.8%. Both media isolated similar fecal coliform populations. The advantages of a single medium, highly effective for the isolation of both total and fecal coliforms, are discussed.  相似文献   

10.
Ammonia-induced injury was investigated in pure cultures of Escherichia coli and Enterobacter aerogenes, and in natural coliform populations obtained from the oligotrophic Luxapallila and the eutrophic Sunflower Rivers in northern Mississippi. Pure cultures were affected by ammonia exposure as indicated by changes in the injury ratio (IR) of CFU on m-T7 agar/CFU on m-Endo agar. Ammonia concentrations between 0 and 20 (mg NH3-N/1) had little or no effect and concentrations between 40 and 80 caused the greatest injury. Natural coliform populations from the oligotrophic river were more prone to ammonia-induced injury than those from the eutrophic river. The results stress the need for the routine use of m-T7 media and the enumeration of injured cells when using the membrane filter procedure to ascertain domestic water quality.  相似文献   

11.
m-T7 agar, designed to improve recoveries of injured total coliforms, was evaluated for its effectiveness as a fecal coliform medium. The time and temperature of preincubation were found to be crucial to the optimal recovery of fetal coliforms. Isolation rates for fecal coliforms on m-T7 agar from sewage effluents were the highest when plates were preincubated at 37 degrees C for 8 h before transfer to 44.5 degrees C for 12 h. The medium was found to produce consistently higher fecal coliform counts than all the other methods tested. Recoveries were 3.1 times greater than the standard m-FC method and 1.7 times greater than the two-layer enrichment, temperature acclimation procedure. Verification rates for fecal coliforms isolated on m-T7 agar averaged 89.0%, whereas verification rates for m-FC agar averaged only 82.8%. Both media isolated similar fecal coliform populations. The advantages of a single medium, highly effective for the isolation of both total and fecal coliforms, are discussed.  相似文献   

12.
The heterotrophic plate counts of 15 brands of bottled non-carbonated mineral waters were examined and found to be generally high and variable. Four selective or enrichment media for the enumeration of coliforms (m-Endo LES and m-lauryl sulphate agar) and Pseudomonas aeruginosa (cetrimide-nalidixic acid agar and malachite green broth) were used to isolate several species of Gram-negative bacteria. Strains identified as CDC gr IVc-2 and Comamonas (Ps.) acidovorans were the two most commonly isolated. Considerable variation in populations was seen between the brands, as well as between two batches of the same mineral water.  相似文献   

13.
AIMS: To investigate changes in the bacterial population and the safety of the biofilm at the end of the drinking water distribution system in Seoul (Korea), selective media and bacterial community analyses were applied to a semi-pilot galvanized iron pipe (GIP) model. METHODS AND RESULTS: No total coliforms or faecal streptococci were detected on m-Endo or m-Enterococcus agar. No Salmonella spp. and Shigella spp. were detected on bismuth sulphite agar or Hektoen enteric agar, respectively. The latter two media detected coliforms, where m-Endo was negative. Biofilm formation started within 1 week (ca 104 CFU cm(-2)) and exceeded 105 CFU cm(-2) within 6 weeks. Although the fatty acid methyl ester analysis revealed dynamic changes in bacterial composition, Micrococcus, Bacillus, and Pseudomonas spp. were persistent members of the biofilm community. Micrococcus spp. was detected most frequently and in high numbers. CONCLUSIONS: Coliforms and Enterococcus species can be recovered from biofilms in water distribution systems. SIGNIFICANCE AND IMPACT OF THE STUDY: This study illustrates the role of biofilms in the chronic deterioration of the water-distribution system in Seoul (Korea).  相似文献   

14.
Recovery of total coliforms and Escherichia coli on a new membrane filtration (MF) medium was evaluated with 25 water samples from seven states. Testing of the new medium, m-ColiBlue24 broth, was conducted according to a U.S. Environmental Protection Agency protocol. For comparison, this same protocol was used to measure recovery of total coliforms and E. coli with two standard MF media, m-Endo broth and mTEC broth. E. coli recovery on the new medium was also compared to recovery on nutrient agar supplemented with 4-methylumbelliferyl-beta-D-glucuronide. Comparison of specificity, sensitivity, false positive error, undetected target error, and overall agreement indicated E. coli recovery on m-ColiBlue24 was superior to recovery on mTEC for all five parameters. Recovery of total coliforms on the new medium was comparable to recovery on m-Endo.  相似文献   

15.
Rural drinking water systems supplied by untreated groundwater were examined to determine whether coliform or heterotrophic plate count bacteria are capable of escaping entrapment on standard porosity (0.45-micron-pore-size) membrane filters. Filterable bacteria were present in 42% of the 24 groundwater sources examined by using nonselective media (R2A, full strength m-HPC, and 0.1x m-HPC agars). Pseudomonads were the most frequently identified group of filterable bacteria detected. Flavobacterium, Alcaligenes, Acinetobacter, and Achromobacter isolates were also identified. Total coliforms were not recovered from any of the 24 groundwater samples following filtration through 0.45-micron-pore-size membrane filters by using selective M-Endo LES agar or mT7 agar. In addition, none of the isolates identified from nonselective media were coliforms. Similarly, neither total coliforms nor specifically Escherichia coli were detected in these filtrates when Colilert P/A medium was used.  相似文献   

16.
A defined substrate method was developed to simultaneously enumerate total coliforms and Escherichia coli from drinking waters without the need for confirmatory or completed tests. It is a new method based on technology that uses a hydrolyzable substrate as a specific indicator-nutrient for the target microbes. No equipment other than a 35 degrees C incubator and long-wavelength (366-nm) light is necessary. To perform the test, one only has to add water to the powdered ingredients in a tube or flask. If total coliforms are present in the water sample, the solution will change from its normal colorless state (no target microbes present) to yellow. The specific presence of E. coli will cause the same tube to fluoresce under a longwave (366-nm) UV lamp. The test, called Autoanalysis Colilert (AC), was compared with Standard Methods for the Examination of Water and Wastewater 10-tube multiple tube fermentation (MTF) in a national evaluation. Five utilities, representing six U.S. Environmental Protection Agency regions, participated. All water samples came from distribution systems. Split samples from a wide variety of water sources were analyzed for the MPN-versus-MPN comparison. A total of 1,086 tubes were positive by MTF, and 1,279 were positive by AC. There was no statistical difference between MTF and AC. Species identifications from positive tubes confirmed the sensitivity of the AC. A national evaluation of the AC test showed that it: (i) was as sensitive as Standard Methods MTF, (ii) specifically enumerated 1 total coliform per 100 ml, in a maximum of 24 h, (iii) simultaneously enumerated 1 E. coli per 100 ml in the same analysis, (iv) was not subject to false-positive or false-negative results by heterotrophic bacteria, (v) did not require confirmatory tests, (vi) grew injured coliforms, (vii) was easy to inoculate, and (viii) was very easy to interpret.  相似文献   

17.
Rural drinking water systems supplied by untreated groundwater were examined to determine whether coliform or heterotrophic plate count bacteria are capable of escaping entrapment on standard porosity (0.45-micron-pore-size) membrane filters. Filterable bacteria were present in 42% of the 24 groundwater sources examined by using nonselective media (R2A, full strength m-HPC, and 0.1x m-HPC agars). Pseudomonads were the most frequently identified group of filterable bacteria detected. Flavobacterium, Alcaligenes, Acinetobacter, and Achromobacter isolates were also identified. Total coliforms were not recovered from any of the 24 groundwater samples following filtration through 0.45-micron-pore-size membrane filters by using selective M-Endo LES agar or mT7 agar. In addition, none of the isolates identified from nonselective media were coliforms. Similarly, neither total coliforms nor specifically Escherichia coli were detected in these filtrates when Colilert P/A medium was used.  相似文献   

18.
A defined substrate method was developed to simultaneously enumerate total coliforms and Escherichia coli from drinking waters without the need for confirmatory or completed tests. It is a new method based on technology that uses a hydrolyzable substrate as a specific indicator-nutrient for the target microbes. No equipment other than a 35 degrees C incubator and long-wavelength (366-nm) light is necessary. To perform the test, one only has to add water to the powdered ingredients in a tube or flask. If total coliforms are present in the water sample, the solution will change from its normal colorless state (no target microbes present) to yellow. The specific presence of E. coli will cause the same tube to fluoresce under a longwave (366-nm) UV lamp. The test, called Autoanalysis Colilert (AC), was compared with Standard Methods for the Examination of Water and Wastewater 10-tube multiple tube fermentation (MTF) in a national evaluation. Five utilities, representing six U.S. Environmental Protection Agency regions, participated. All water samples came from distribution systems. Split samples from a wide variety of water sources were analyzed for the MPN-versus-MPN comparison. A total of 1,086 tubes were positive by MTF, and 1,279 were positive by AC. There was no statistical difference between MTF and AC. Species identifications from positive tubes confirmed the sensitivity of the AC. A national evaluation of the AC test showed that it: (i) was as sensitive as Standard Methods MTF, (ii) specifically enumerated 1 total coliform per 100 ml, in a maximum of 24 h, (iii) simultaneously enumerated 1 E. coli per 100 ml in the same analysis, (iv) was not subject to false-positive or false-negative results by heterotrophic bacteria, (v) did not require confirmatory tests, (vi) grew injured coliforms, (vii) was easy to inoculate, and (viii) was very easy to interpret.  相似文献   

19.
AIMS: Enumeration of coliform bacteria and Escherichia coli is the most widely used method in the estimation of hygienic quality of drinking water. The yield of target bacteria and the species composition of different populations of coliform bacteria may depend on the method.Three methods were compared. METHODS AND RESULTS: Three membrane filtration methods were used for the enumeration of coliform bacteria in shallow well waters. The yield of confirmed coliform bacteria was highest on Differential Coliform agar, followed by LES Endo agar. Differential Coliform agar had the highest proportion of typical colonies, of which 74% were confirmed as belonging to the Enterobacteriaceae. Of the typical colonies on Lactose Tergitol 7 TTC agar, 75% were confirmed as Enterobacteriaceae, whereas 92% of typical colonies on LES Endo agar belonged to the Enterobacteriaceae. LES Endo agar yielded many Serratia strains, Lactose Tergitol 7 TTC agar yielded numerous strains of Rahnella aquatilis and Enterobacter, whereas Differential Coliform agar yielded the widest range of species. CONCLUSION: The yield of coliform bacteria varied between methods. Each method compared had a characteristic species distribution of target bacteria and a typical level of interference of non-target bacteria. Identification with routine physiological tests to distinct species was hampered by the slight differences between species. High yield and sufficient selectivity are difficult to achieve simultaneously, especially if the target group is diverse. SIGNIFICANCE AND IMPACT OF THE STUDY: The results showed that several aspects of method performance should be considered, and that the target group must be distinctly defined to enable method comparisons.  相似文献   

20.
Evaluations of several commercial presence-absence (P-A) test kits were performed over a 6-month period in 1990 by using the Ontario Ministry of the Environment (MOE) P-A test for comparison. The general principles of the multiple-tube fermentation technique formed the basis for conducting the product evaluations. Each week, a surface water sample was diluted and inoculated into 25 99-ml dilution blanks for each of three dilutions. The inoculated dilution blanks from each dilution series were randomly sorted into sets of five. Three of these sets were inoculated into the P-A test kits or vice versa, as required. The other two sets were passed through membrane filters, and one set of five membrane filters was placed onto m-Endo agar LES to give replicate total coliform counts and the other set was placed onto m-TEC agar to give replicate fecal coliform results. A statistical analysis of the results was performed by a modified logistic transform method, which provided an improved way to compare binary data obtained from the different test kits. The comparative test results showed that three of the four commercial products tested gave very good levels of recovery and that the fourth commercial product gave only fair levels of recovery when the data were compared with the data from MOE P-A tests and membrane filter tests. P-A bottles showing positive results after 18 h of incubation that were subcultured immediately in ECMUG tubes frequently could be confirmed as containing total coliforms, fecal coliforms, or Escherichia coli after 6 h of incubation; thus, the total incubation time was only 24 h.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号