首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 18 毫秒
1.
Glucose oxidase was embedded in organic films through a layer-by-layer approach, where the enzyme demonstrated significantly enhanced electron-transfer reactivity and finely tuned enzymatic activity. An unmediated, reagentless glucose biosensor was accordingly prepared with two polyethylenimine/glucose oxidase bilayers-modified pyrolytic graphite electrode. A calibration linear range of glucose was 0.5-8.9 mM with a detection limit of 50 microM and sensitivity of 0.76 microA mM(-1).  相似文献   

2.
Zou Y  Sun LX  Xu F 《Biosensors & bioelectronics》2007,22(11):2669-2674
In this work, a novel route for fabrication polyaniline (PANI)-Prussian Blue (PB) hybrid composites is proposed by the spontaneous redox reaction in the FeCl(3)-K(3)[Fe(CN)(6)] and the aniline solution. With the introduction of multi-walled carbon nanotubes (MWNTs), the PANI-PB/MWNTs system shows synergy between the PANI-PB and MWNTs which amplified the H(2)O(2) sensitivity greatly. A linear range from 8 x1 0(-8) to 1 x 10(-5)M and a high sensitivity 508.1 8 microA microM cm(2) for H(2)O(2) detection are obtained. The composites also show good stability in neutral solution. A glucose biosensor was further constructed by immobilizing glucose oxidase (GOD) with Nafion and glutaraldehyde on the electrode surface. The performance factors influencing the resulted biosensor were studied in detail. The biosensor exhibits excellent response performance to glucose with the linear range from 1 to 11 mM and a detection limit of 0.01 mM. Furthermore, the biosensor shows rapid response, high sensitivity, good reproducibility, long-term stability and freedom of interference from other co-existing electroactive species.  相似文献   

3.
This work shows excellent catalytic activity of soluble carbon nanofiber (CNF), which was obtained with a simple nitric acid treatment, toward the electroreduction of dissolved oxygen at a low operating potential. Thus the CNF was applied in the construction of amperometric biosensors for oxidase substrates using glucose oxidase as a model. The good dispersion of CNF led to convenient preparation and acceptable repeatability of the proposed sensors. UV-vis spectra, Fourier transform infrared spectra, X-ray photoelectron spectra and titration curves demonstrated that the good dispersion resulted from the large numbers of surface oxygen-rich groups produced in the treatment process. The membrane of CNF showed good stability and provided fast response to dissolved oxygen with a linear range from 0.1 to 78 microM and detection limit of 0.07 microM. The proposed glucose biosensor could monitor glucose ranging from 10 to 350 microM with detection limit of 2.5 microM and sensitivity of 36.3 nA cm(-2) microM(-1). The coefficients of variation for intra-assay were 4.7 and 3.2% at glucose concentrations of 20 and 210 microM, respectively. The use of a low operating potential (-0.3 V) and Nafion membrane produced good selectivity toward the glucose detection. CNF-based biosensors would provide wide range of bioelectrochemical applications in different fields.  相似文献   

4.
In this work the sensitivity-increasing effect of single-walled carbon nanotubes (SWCNTs) in amperometric biosensors, depending on their average length distribution, was studied. For this purpose the SWCNTs were oxidatively shortened and subsequently length separated by size exclusion chromatography. Transmission electron micrographs of different fractions of SWCNTs were collected. Diaphorase "wired" to an osmium redox polymer was blended with the shortened SWCNTs of different lengths. Depending on the average length of the SWCNTs the sensitivity of the amperometric biosensor model system towards oxidation of 1,4-dihydronicotinamide adenine dinucleotide (NADH) was increased by a factor of five. The best performance was achieved with SWCNTs of medium length. The linear range for NADH detection was between 5muM and 7mM, the maximum sensitivity was 47nAmuM(-1)cm(-2), and the detection limit was 1muM. The biosensor exhibited excellent electrocatalytic properties. Even at relatively high NADH concentrations the oxidative current was limited by the diffusion rate of NADH.  相似文献   

5.
For the first time glucose oxidase (GOx) was successfully co-deposited on nickel-oxide (NiO) nanoparticles at a glassy carbon electrode. In this paper we present a simple fabrication method of biosensor which can be easily operated without using any specific reagents. Cyclic voltammetry was used for electrodeposition of NiO nanoparticle and GOx immobilization. The direct electron transfer of immobilized GOx displays a pair of well defined and nearly reversible redox peaks with a formal potential (E(0')) of -0.420 V in pH 7 phosphate buffer solution and the response shows a surface controlled electrode process. The surface coverage and heterogeneous electron transfer rate constant (k(s)) of GOx immobilized on NiO film glassy carbon electrode are 9.45 x 10(-13)mol cm(-2) and 25.2+/-0.5s(-1), indicating the high enzyme loading ability of the NiO nanoparticles and great facilitation of the electron transfer between GOx and NiO nanoparticles. The biosensor shows excellent electrocatalytical response to the oxidation of glucose when ferrocenmethanol was used as an artificial redox mediator. Furthermore, the apparent Michaelis-Menten constant 2.7 mM, of GOx on the nickel oxide nanoparticles exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. In addition, this glucose biosensor shows fast amperometric response (3s) with the sensitivity of 446.2nA/mM, detection limit of 24 microM and wide concentration range of 30 microM to 5mM. This biosensor also exhibits good stability, reproducibility and long life time.  相似文献   

6.
Reduced graphene oxide/PAMAM-silver nanoparticles nanocomposite (RGO-PAMAM-Ag) was synthesized by self-assembly of carboxyl-terminated PAMAM dendrimer (PAMAM-G3.5) on graphene oxide (GO) as growing template, and in-situ reduction of both AgNO(3) and GO under microwave irradiation. The RGO-PAMAM-Ag nanocomposite was used as a novel immobilization matrix for glucose oxidase (GOD) and exhibited excellent direct electron transfer properties for GOD with the rate constant (K(s)) of 8.59 s(-1). The fabricated glucose biosensor based on GOD electrode modified with RGO-PAMAM-Ag nanocomposite displayed satisfactory analytical performance including high sensitivity (75.72 μA mM(-1) cm(-2)), low detection limit (4.5 μM), an acceptable linear range from 0.032 mM to 1.89 mM, and also preventing the interference of some interfering species usually coexisting with glucose in human blood at the work potential of -0.25 V. These results indicated that RGO-PAMAM-Ag nanocomposite is a promising candidate material for high-performance glucose biosensors.  相似文献   

7.
Calcium carbonate nanoparticles (nano-CaCO3) may be a promising material for enzyme immobilization owing to their high biocompatibility, large specific surface area and their aggregation properties. This attractive material was exploited for the mild immobilization of glucose oxidase (GOD) in order to develop glucose amperometric biosensor. The GOD/nano-CaCO3-based sensor exhibited a marked improvement in thermal stability compared to other glucose biosensors based on inorganic host matrixes. Amperometric detection of glucose was evaluated by holding the modified electrode at 0.60 V (versus SCE) in order to oxidize the hydrogen peroxide generated by the enzymatic reaction. The biosensor exhibited a rapid response (6s), a low detection limit (0.1 microM), a wide linear range of 0.001-12 mM, a high sensitivity (58.1 mAcm-2M-1), as well as a good operational and storage stability. In addition, optimization of the biosensor construction, the effects of the applied potential as well as common interfering compounds on the amperometric response of the sensor were investigated and discussed herein.  相似文献   

8.
A sensitive, selective and stable amperometric glucose biosensor employing novel PtPd bimetallic nanoparticles decorated on multi-walled carbon nanotubes (PtPd-MWCNTs) was investigated. PtPd-MWCNTs were prepared by a modified Watanabe method, and characterized by XRD and TEM. The biosensor was constructed by immobilizing the PtPd-MWCNTs catalysts in a Nafion film on a glassy carbon electrode. An inner Na?on film coating was used to eliminate common interferents such as uric acid, ascorbic acid and fructose. Finally, a highly porous surface with an orderly three-dimensional network enzyme layer (CS-GA-GOx) was fabricated by electrodeposition. The resulting biosensor exhibited a good response to glucose with a wide linear range (0.062-14.07 mM) and a low detection limit 0.031 mM. The biosensor also showed a short response time (within 5 s), and a high sensitivity (112 μA mM(-1)cm(-2)). The Michaelis-Menten constant (K(m)) was determined as 3.3 mM. In addition, the biosensor exhibited high reproducibility, good storage stability and satisfactory anti-interference ability. The applicability of the biosensor to actual serum sample analysis was also evaluated.  相似文献   

9.
Luo XL  Xu JJ  Du Y  Chen HY 《Analytical biochemistry》2004,334(2):284-289
An amperometric biosensor for the quantitative measurement of glucose is reported. The biosensor is based on a biocomposite that is homogeneous and easily prepared. This biocomposite is made of chitosan hydrogel, glucose oxidase, and gold nanoparticles by a direct and facile electrochemical deposition method under enzyme-friendly conditions. The resulting biocomposite provided a shelter for the enzyme to retain its bioactivity at considerably extreme conditions, and the decorated gold nanoparticles in the biocomposite offer excellent affinity to enzyme. The biosensor exhibited a rapid response (within 7s) and a linear calibration range from 5.0 microM to 2.4 mM with a detection limit of 2.7 microM for the detection of glucose. The combination of gold nanoparticles affinity and the promising feature of the biocomposite with the onestep nonmanual technique favor the sensitive determination of glucose with improved analytical capabilities.  相似文献   

10.
Screen-printed amperometric glucose biosensors have been fabricated using a water-based carbon ink. The enzyme glucose oxidase (GOD) and the electro-catalyst cobalt phthalocyanine were mixed with the carbon ink prior to the screen-printing process; therefore, biosensors are prepared in a one-step fabrication procedure. Optimisation of the biosensor performance was achieved by studying the effects of pH, buffer strength, and applied potential on the analytical response. Calibration studies were performed under optimum conditions, using amperometry in stirred solution, with an operating potential of +500 mV versus SCE. The sensitivity was found to be 1170 nA mM(-1), with a linear range of 0.025-2 mM; the former represents the detection limit. The disposable amperometric biosensor was evaluated by carrying out replicate determinations on a sample of bovine serum. This was achieved by the method of multiple standard additions and included a correction for background currents arising from oxidizable serum components. The mean serum concentration was calculated to be 8.63 mM and compared well with the supplier's value of 8.3 mM; the coefficient of variation was calculated to be 3.3% (n=6).  相似文献   

11.
A new glucose biosensor has been fabricated by immobilizing glucose oxidase into a sol-gel composite at the surface of a basal plane pyrolytic graphite (bppg) electrode modified with multiwall carbon nanotube. First, the bppg electrode is subjected to abrasive immobilization of carbon nanotubes by gently rubbing the electrode surface on a filter paper supporting the carbon nanotubes. Second, the electrode surface is covered with a thin film of a sol-gel composite containing encapsulated glucose oxidase. The carbon nanotubes offer excellent electrocatalytic activity toward reduction and oxidation of hydrogen peroxide liberated in the enzymatic reaction between glucose oxidase and glucose, enabling sensitive determination of glucose. The amperometric detection of glucose is carried out at 0.3 V (vs saturated calomel electrode) in 0.05 M phosphate buffer solution (pH 7.4) with linear response range of 0.2-20 mM glucose, sensitivity of 196 nA/mM, and detection limit of 50 microM (S/N=3). The response time of the electrode is < 5s when it is stored dried at 4 degrees C, the sensor showed almost no change in the analytical performance after operation for 3 weeks. The present carbon nanotube sol-gel biocomposite glucose oxidase sensor showed excellent properties for the sensitive determination of glucose with good reproducibility, remarkable stability, and rapid response and in comparison to bulk modified composite biosensors the amounts of enzyme and carbon nanotube needed for electrode fabrication are dramatically decreased.  相似文献   

12.
A fluorescent glucose biosensor was constructed by immobilizing glucose oxidase on a bamboo inner shell membrane with glutaraldehyde as a cross-linker. The detection scheme was based on the depletion of dissolved oxygen content upon exposure to glucose solution with a concomitant increase in the fluorescence intensity of an oxygen transducer, tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(Pi) ditetrakis(4-chlorophenyl)borate. The enzyme immobilization, effect of pH, temperature and ionic strength have been studied in detail. The biosensor exhibited repeatable response to a 2.0 mM glucose solution with a relative standard deviation of 3.0% (n = 10). It showed good storage stability and maintained 95% of its initial response after it had been kept at 4 degrees C for 8 months. The biosensor has a linear response range of 0.0-0.6 mM glucose with a detection limit of 58 microM (S/N = 3). Common potential interferants in samples do not pose any significant interference on the response of the glucose biosensor. It was successfully applied to the determination of glucose content in some commercial wines and medical glucose injections.  相似文献   

13.
A biosensor for glucose using glucose dehydrogenase immobilized on a chemically modified graphite electrode was supplied with coenzyme, nicotinamide adenine dinucleotide (NAD+), through pores in the material. A graphite rod was hollowed out, leaving 0.3 mm at the end contacting the solution, filled with 10 mM NAD+ and pressurized. The response factor was 40% of that obtained when 2 mM NAD+ was mixed with the sample solution in a flow system. The coenzyme consumption was 11 microliters h-1 representing a 500-fold saving compared to supply through the bulk solution. The biosensor had a linear calibration curve from the detection limit, 1 microM, to 2 mM glucose and a repeatability of 0.3%. The graphite electrode was modified by adsorption of a bis-(benzophenoxazinyl)-terephthaloyl derivative in order to be able to oxidize NADH at 0 mV versus Ag/AgCl, 0.1 M KCl.  相似文献   

14.
A new amperometric, nanostructured sensor for the analytical determination of hydrogen peroxide is proposed. This sensor was constructed by immobilizing silver nanoparticles in a polyvinyl alcohol (PVA) film on a platinum electrode, which was performed by direct drop-casting silver nanoparticles that were capped in a PVA colloidal suspension. UV-vis spectroscopy, X-ray diffraction and transmission electron microscopy were used to give a complete characterization of the nanostructured film. Cyclic voltammetry experiments yielded evidence that silver nanoparticles facilitate hydrogen peroxide reduction, showing excellent catalytic activity. Moreover, the cronoamperometric response of modified sensors was dependent on nanoparticle lifetime. Experiments were performed, using freshly prepared solutions, after 4 and 8 days. Results concerning the quantitative analysis of hydrogen peroxide, in terms of detection limit, linear range, sensitivity and standard deviation (STD), are discussed for each tested sensor type. Utilization of two different linear ranges (40 microM to 6mM and 1.25 microM to 1.0mM) enabled the assessment of concentration intervals having up to three orders of magnitude. Moreover, the electrode made using a 4-day-old solution showed the maximal sensitivity of 128 nA microM(-1)(4090 nA microM(-1)cm(-2)), yielding a limit of detection of 1 microuM and STD of 2.5 microAmM(-1). All of these analytical parameters make the constructed sensors suitable for peroxide determination in aqueous solution.  相似文献   

15.
A glutamate biosensor based on the electrocatalytic oxidation of reduced nicotinamide adenine dinucleotide (NADH), which was generated by the enzymatic reaction, was developed via employing a single-walled carbon nanotubes/thionine (Th-SWNTs) nanocomposite as a mediator and an enzyme immobilization matrix. The biosensor, which was fabricated by immobilizing glutamate dehydrogenase (GlDH) on the surface of Th-SWNTs, exhibited a rapid response (ca. 5s), a low detection limit (0.1 microM), a wide and useful linear range (0.5-400 microM), high sensitivity (137.3+/-15.7) microA mM(-1)cm(-2), higher biological affinity, as well as good stability and repeatability. In addition, the common interfering species, such as ascorbic acid, uric acid, and 4-acetamidophenol, did not cause any interference due to the use of a low operating potential (190 mV vs. NHE). The biosensor can be used to quantify the concentration of glutamate in the physiological level. The Th-SWNTs system represents a simple and effective approach to the integration of dehydrogenase and electrodes, which can provide analytical access to a large group of enzymes for wide range of bioelectrochemical applications including biosensors and biofuel cells.  相似文献   

16.
A new strategy for immobilization of horseradish peroxidase (HRP) has been presented by self-assembling gold nanoparticles on chitosan hydrogel modified Au electrode. From a mildly acidic chitosan solution, a chitosan film is electrochemically deposited on Au electrode surface via a negative voltage bias. This process is accompanied by the hydrogen evolution reaction, and the released hydrogen gas made the deposited chitosan film with porous structure, which facilitates the assembly of gold nanoparticles and HRP. The resulting substrates were characterized by atomic force microscopy (AFM) and electrochemical impedance spectroscopy (EIS). The immobilized HRP displayed an excellent catalytic property to the reduction of H2O2 in the presence of methylene blue mediator. The resulting biosensor (HRP-modified electrode) showed a wide dynamic range of 8.0 microM-15 mM H2O2, and the linear ranges were 8.0 microM-0.12 mM and 0.50-12 mM, with a detection limit of 2.4 microM estimated at a signal-to-noise ratio of 3. Moreover, the biosensor remained about 85% of its original sensitivity after four weeks' storage.  相似文献   

17.
Platinum nanowires (PtNWs) prepared by electrodeposition method with the help of porous anodic aluminum oxide (AAO) templates have been solubilized in chitosan (CHIT) together with carbon nantubes (CNTs) to form a PtNW-CNT-CHIT organic-inorganic system. The resulting PtNW-CNT-CHIT material brings capabilities for utilizing synergic action of PtNWs and CNTs to facilitate electron-transfer process in electrochemical sensor design. The PtNW-CNT-CHIT film modified electrode offered a significant decrease in the overvoltage for the hydrogen peroxide and showed to be excellent amperometric sensors for hydrogen peroxide at -0.1 V over a wide range of concentrations, and the sensitivity is 260 microAmM-1cm-2. As an application example, by linking glucose oxidase (GOx), an amplified biosensor toward glucose was prepared. The glucose biosensor exhibits a selective determination of glucose at -0.1 V with a linear response range of 5 x 10(-6) to 1.5 x 10(-2)M with a correlation coefficient of 0.997, and response time <10s. The high sensitivity of the glucose biosensor is up to 30 microAmM-1cm-2 and the detection limit was 3 microM. The biosensor displays rapid response and expanded linear response range, and excellent repeatability and stability.  相似文献   

18.
A novel amperometric biosensor, based on electrodeposition of platinum nanoparticles onto multi-walled carbon nanotube (MWNTs) and immobilizing enzyme with chitosan-SiO(2) sol-gel, is presented in this article. MWNTs were cast on the glass carbon (GC) substrate directly. An extra Nafion coating was used to eliminate common interferents such as acetaminophen and ascorbic acids. The morphologies and electrochemical performance of the modified electrodes have been investigated by scanning electron microscopy (SEM) and amperometric methods, respectively. The synergistic action of Pt and MWNTs and the biocompatibility of chitosan-SiO(2) sol-gel made the biosensor have excellent electrocatalytic activity and high stability. The resulting biosensor exhibits good response performance to glucose with a wide linear range from 1 microM to 23 mM and a low detection limit 1 microM. The biosensor also shows a short response time (within 5s), and a high sensitivity (58.9 microAm M(-1)cm(-2)). In addition, effects of pH value, applied potential, rotating rate, electrode construction and electroactive interferents on the amperometric response of the sensor were investigated and discussed in detail.  相似文献   

19.
A new type of sol-gel-derived titanium oxide/copolymer composite material was developed and used for the construction of glucose biosensor. The composite material merged the best properties of the inorganic species, titanium oxide and the organic copolymer, poly(vinyl alcohol) grafting 4-vinylpyridine (PVA-g-PVP). The glucose oxidase entrapped in the composite matrix retained its bioactivity. Morphologies of the composite-modified electrode and the enzyme electrode were characterized with a scanning electron microscope. The dependence of the current responses on enzyme-loading and pH was studied. The response time of the biosensor was < 20 s and the linear range was up to 9 microM with a sensitivity of 405 nA/microM. The biosensor was stable for at least 1 month. In addition, the tetrathiafulvalene-mediated enzyme electrode was constructed for the decrease of detection potential and the effect of three common physiological sources that might interfere was also investigated.  相似文献   

20.
The properties of amperometric biosensors based on methanol dehydrogenase (MDH) Methylobacterium nodulans, cells, and the ferrocene-modified carbon paste electrode were investigated. It was shown that the addition of hydroxyapatite (HA) to a carbon paste increased the sensitivity and operating stability of MDH biosensors. The linear range of the electrode was 0.0135–0.5 and 0.032–1.5 mM for methanol and formaldehyde, respectively. The detection limit of methanol and formaldehyde was 4.5 and 11.0 μM, respectively. The loss of activity of the electrode within 10 days of storage in the presence of 2.0 mM KCN did not exceed 12%. Cyanide (10 mM) completely inhibited the sensor responses to formaldehyde (1.0 mM), which allowed for the selective determination of methanol in the presence of formaldehyde. The biosensor based on cells exhibited lower stability and sensitivity toward methanol and formaldehyde; the sensitivity coefficients were 980 and 21 nA/mM, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号