首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new method has been developed for the continuous measurement of aortic blood velocity in patients following cardiac surgery. Using an extractable Doppler ultrasound probe placed on the ascending aorta, the changes in aortic velocity were recorded up to 24 h postoperatively, in 14 patients undergoing coronary bypass surgery. Volume flow rate is calculated from the mean velocity, the diameter of the aorta and the angle between the ultrasound beam and the direction of the blood flow, by means of an analogue flow calculator. Estimation of aortic flow showed a correlation of r = 0.79 with cardiac output measured by a thermodilution technique. The main advantage of the system is that it allows continuous monitoring of cardiac output, as well as short and long-term trend analyses, during the early postoperative period.  相似文献   

2.
Transesophageal echocardiography offers a noninvasive technique for the continuous monitoring of cardiac performance. The combination of 2-dimensional echocardiography and Doppler velocitometry provide assessment of cardiac anatomy, valve function and, ventricular loading conditions. Although transesophageal echocardiography has become accepted for perioperative monitoring, it is typically used in conjunction with Swan-Ganz catheterization. To supplant Swan-Ganz catheters, an echocardiographic technique to monitor cardiac output is necessary. Despite considerable effort to achieve this goal, a satisfactory technique has been difficult to realize. This paper discusses the role of cardiac output monitoring in perioperative care and critically examines echocardiographic techniques for cardiac output monitoring.  相似文献   

3.
Currently, no reliable minimally invasive method of measuring cardiac output continuously in neonates and children undergoing cardiac surgery is available. An extravascular Doppler probe was used to measure cardiac output in 15 New Zealand White rabbits (average weight 3.5 kg, range 2.5-4.5 kg). The results obtained were compared with cardiac outputs determined using the aortic thermodilution principle. The mean cardiac outputs measured with the extravascular Doppler probe was 0.37 +/- 0.01 l/min as compared with 0.39 +/- 0.01 l/min with aortic thermodilution. Regression analysis revealed a close correlation (r = 0.973) between the two techniques. The extravascular Doppler techniques is an option for continuous and reliable cardiac output measurement in small animals used in surgical experiments (open chest models) and in neonates or children during surgical repair of complicated congenital heart conditions.  相似文献   

4.
We have determined the gain of the cardiopulmonary baroreflex (CPBR) by measuring the central venous pressure (CVP) by venous catheter and calculating the total peripheral resistance (TPR) from mean arterial pressure (MAP) by Finometer and cardiac output (QD) by Doppler ultrasound. We tested the hypothesis that the BeatScope software of the Finometer, which calculates cardiac stroke volume (SVF) and cardiac output (QF) from the arterial pulse wave, could provide data with which to estimate CVP and TPR. The estimate of QF was linearly related to QD with a correction factor. Further, we found linear relationships between CVP and SVF that allowed us to establish a prediction of CVP from the SVF as the new input to the CPBR. To test the ability of this method to monitor changes in CPBR we are testing the subjects of the WISE-2005 study before and after 50-days of bed rest. We conclude that the TPR can be assessed with the Finometer and without any invasive method to record the CVP.  相似文献   

5.
Characterizing embryonic circulatory physiology requires accurate cardiac output and flow data. Despite recent applications of high-frequency ultrasound Doppler to the study of embryonic circulation, current Doppler analysis of volumetric flow is relatively crude. To improve Doppler derivation of volumetric flow, we sought a preliminary model of the spatial velocity profile in the mouse embryonic dorsal aorta using ultrasound biomicroscopy (UBM)-Doppler data. Embryonic hematocrit is 0.05-0.10 so rheologic properties must be insignificant. Low Reynolds numbers (<500) and Womersley parameters (<0.76) suggest laminar flow. UBM demonstrated a circular dorsal aortic cross section with no significant tapering. Low Dean numbers (<100) suggest the presence of minimal skewing of the spatial velocity profile. The inlet length allows for fully developed flow. There is no apparent aortic wall pulsatility. Extrapolation of prior studies to these vessel diameters (300-350 microm) and flow velocities (~50-200 mm/s) suggests parabolic spatial velocity profiles. Therefore, mouse embryonic dorsal aortic blood flow may correspond to Poiseuille flow in a straight rigid tube with parabolic spatial velocity profiles. As a first approximation, these results are an important step toward precise in utero ultrasound characterization of blood flow within the developing mammalian circulation.  相似文献   

6.
For the investigation of flow through prosthetic arteries a pulsed Doppler ultrasound system has been characterized. Preliminary in vitro experiments using this system are described; they verify its suitability for making velocity profile and flow disturbance measurements. The output from a frequency tracker is compared with spectral analysis of Doppler signals for both laminar and turbulent flow regimes and the root mean square fluctuations on the tracker output signal are used to identify transition from laminar to turbulent flow. In addition, the turbulent itensity of poststenotic flow is quantified at several axial locations and for different rates of flow. Finally, we present velocity profile measurements which were obtained using a deconvolution technique to account for the finite size of the sample volume.  相似文献   

7.
OBJECTIVE--To assess oesophageal Doppler ultrasonography as a convenient means of optimising positive end expiratory pressure for maximal delivery of oxygen to tissues. DESIGN--Measurements of blood flow, arterial oxygen saturation, and cardiac output by thermodilution (when available) at baseline and at 20-30 minutes after each incremental increase (2.5-5.0 cm H2O) in positive and expiratory pressure to a maximum of 20.0 cm H2O. If the cardiac output fell by more than 15% measurements were repeated after stepwise decreases in positive end expiratory pressure. No other manoeuvre such as endotracheal suction or changing ventilator settings, drug or fluid dosage, or the patient''s position was performed for at least one hour before the start of the study or during it. SETTING--Intensive care unit. PARTICIPANTS--10 Patients being mechanically ventilated for acute respiratory failure who had stable haemodynamic and blood gas values and required a fractional inspired oxygen concentration of greater than or equal to 0.45. They were assessed on a total of 11 occasions. INTERVENTIONS--Incremental increases in positive end expiratory pressure followed when indicated by stepwise decreases. END POINT--The positive end expiratory pressure providing maximal delivery of oxygen to tissues. MEASUREMENTS and MAIN RESULTS--Arterial oxygen saturation increased with positive end expiratory pressure in all patients by an average of 6.1%. In nine of the 11 studies, however, cardiac output fell by 15% to 30% after the second increment. On the two other occasions cardiac output and oxygen delivery rose by up to 54%. Positive end expiratory pressure was decreased on seven occasions; there was considerable individual variation in the time taken for cardiac output to rise and arterial oxygen saturation to fall. In six patients good agreement was seen between the results from Doppler ultrasonography and thermodilution, the mean of the differences being -0.3% with narrow limits of agreement (-14.4% to 13.9%). CONCLUSIONS--Oesophageal Doppler ultrasonography is a rapid, safe, and reliable technique for optimising positive end expiratory pressure to obtain maximal delivery of oxygen to tissues. The results show the need to consider haemodynamic consequences when altering positive end expiratory pressure.  相似文献   

8.
Echocardiography plays an integral role in the detection of mechanical dyssynchrony in patients with congestive heart failure and in predicting beneficial response to cardiac resynchronization treatment. In patients who derive sup-optimal benefit from biventricular pacing, optimization of atrioventricular delay post cardiac resynchronization treatment has been shown to improve cardiac output. Some recent reports suggest that sequential ventricular pacing may further improve cardiac output. The mechanism whereby sequential ventricular pacing improves cardiac output is likely improved inter and possibly intraventricular synchrony, however these speculations have not been confirmed. In this report we describe the beneficial effect of sequential V-V pacing on inter and intraventricular synchrony, cardiac output and mitral regurgitation severity as the mechanisms whereby sequential biventricular pacing improves cardiac output and functional class in 8 patients who had derived no benefit or had deteriorated after CRT. Online tissue Doppler imaging including tissue velocity imaging, tissue synchronization imaging and strain and strain rate imaging were used in addition to conventional pulsed wave and color Doppler during sequential biventricular pacemaker programming.  相似文献   

9.
目的:探讨四维彩超技术在筛查胎儿先天性心脏病的应用价值。方法:择取我院2012年3月至2014年3月收治的行产前筛查的300例产妇为研究对象,采用四维彩色多普勒超声择取心脏三血管、四腔观、肺动脉分叉、上下腔静脉回流、动脉导管弓、主动脉弓等常规切面,予以胎心各腔血流及胎心率等多项检测,对胎儿是否存在先心病进行综合诊断,并综合胎儿大体解剖状况,与病理诊断及二维超声检查结果进行对比。结果:四维彩超检出率为6.67%,正确率为90.00%;二维超声检出率为6.00%,正确率为83.33%,两组比较差异具有统计学意义(P0.05)。结论:四维彩超技术在筛查胎儿先天性心脏病中具有至关重要的应用价值,有助于指导胎儿先天性心脏病早期治疗,保证患儿预后,值得临床借鉴。  相似文献   

10.
两种心衰模型大鼠心功能的比较   总被引:10,自引:2,他引:8  
目的 比较两种心衰模型大鼠心功能的特点。方法 用腹主动脉、下腔静脉穿刺造瘘法及冠脉结扎法建立不同的心衰模型 ,用Doppler超声心动图及心脏称重的方法比较其心功能的各项参数。结果 两组大鼠的相对心脏重量均有所增高。造瘘组射血分数有所下降 ,但心输出量、血压维持正常 ,而冠脉结扎组术后 3周射血分散、心输出量和平均动脉压均明显下降 ,等容舒张期延长。结论 腹主动脉、下腔静脉穿刺造瘘所造成的是高输出量心衰 ,而冠脉结扎法所造成的是低输出量心衰 ,其心衰程度更为严重。Doppler超声心动图为大鼠心功能的检测提供了一种简单、可靠、可随访的无创伤性检查方法。  相似文献   

11.
摘要 目的:分析心脏彩超检查联合血清B型钠尿肽(BNP)、白蛋白(ALB)、胱抑素C(CysC)在慢性心力衰竭(CHF)患者预后评估中的临床价值。方法:选取2017年6月-2018年5月我院收治的123例CHF患者,心脏彩超检查左心室射血分数(LVEF)、左心房内径(LAD)和左心室内径(LVD),实验室检测血清BNP、ALB、CysC水平。按照3年随访后患者是否死亡分为死亡组35例和存活组88例,收集临床资料,采用多因素Logistic回归分析CHF患者预后的影响因素。采用受试者工作特征(ROC)曲线分析心脏彩超检查联合血清BNP、ALB、CysC对CHF患者预后的评估价值。结果:死亡组患者的LAD、LVD及血清BNP、CysC水平高于存活组患者,而LVEF及血清ALB水平低于存活组患者(P<0.05)。心脏彩超指标LVEF、LAD、LVD及血清BNP、ALB、CysC是CHF患者预后的影响因素(P<0.05)。心脏彩超指标LVEF、LAD、LVD联合血清BNP、ALB、CysC检测对CHF患者预后评估的ROC曲线下面积(AUC)(0.95CI)为0.857(0.771~0.938),灵敏度及特异度分别为0.914(32/35)、0.795(70/88),均明显高于上述各指标单独检测。结论:心脏彩超指标LVEF、LAD、LVD和血清BNP、ALB、CysC均为CHF患者预后的影响因素,且联合检测对患者预后的评估价值较高,具有一定的临床应用价值。  相似文献   

12.
Transthoracic echocardiography is a primary non-invasive modality for investigation of heart transplant recipients. It is a versatile tool which provides comprehensive information about cardiac structure and function. Echocardiographic examinations can be easily performed at the bedside and serially repeated without any patient's discomfort. This review highlights the usefulness of Doppler echocardiography in the assessment of left ventricular and right ventricular systolic and diastolic function, of left ventricular mass, valvular heart disease, pulmonary arterial hypertension and pericardial effusion in heart transplant recipients. The main experiences performed by either standard Doppler echocardiography and new high-tech ultrasound technologies are summarised, pointing out advantages and limitations of the described techniques in diagnosing acute allograft rejection and cardiac graft vasculopathy. Despite the sustained efforts of echocardiographic technique in predicting the biopsy state, endocardial myocardial biopsies are still regarded as the gold standard for detection of acute allograft rejection. Conversely, stress echocardiography is able to identify accurately cardiac graft vasculopathy and has a recognised prognostic in this clinical setting. A normal stress-echo justifies postponement of invasive studies. Another use of transthoracic echocardiography is the monitorisation and the visualisation of the catheter during the performance of endomyocardial biopsy. Bedside stress echocardiography is even useful to select appropriately heart donors with brain death. The ultrasound monitoring is simple and effective for monitoring a safe performance of biopsy procedures.  相似文献   

13.
The aim of this study was to measure the cardiac output and stroke volume for a healthy subject by coupling an echocardiogram Doppler (echo-Doppler) method with a fluid–structure interaction (FSI) simulation at rest and during exercise. Blood flow through aortic valve was measured by Doppler flow echocardiography. Aortic valve geometry was calculated by echocardiographic imaging. An FSI simulation was performed, using an arbitrary Lagrangian–Eulerian mesh. Boundary conditions were defined by pressure loads on ventricular and aortic sides. Pressure loads applied brachial pressures with (stage 1) and without (stage 2) differences between brachial, central and left ventricular pressures. FSI results for cardiac output were 15.4% lower than Doppler results for stage 1 (r = 0.999). This difference increased to 22.3% for stage 2. FSI results for stroke volume were undervalued by 15.3% when compared to Doppler results at stage 1 and 26.2% at stage 2 (r = 0.94). The predicted mean backflow of blood was 4.6%. Our results show that numerical methods can be combined with clinical measurements to provide good estimates of patient-specific cardiac output and stroke volume at different heart rates.  相似文献   

14.
目的:探讨心脏彩超评估高血压左心室肥厚(LVH)伴左心衰竭患者心功能的临床价值,分析其超声指标与美国纽约心脏病协会(NYHA)分级的相关性。方法:选择2017年5月至2018年5月我院收治的127例高血压LVH伴左心衰竭患者为观察组,根据NYHA分级将其分为NYHAⅡ级组(41例)、Ⅲ级组(47例)、Ⅳ级组(39例),另选择100例体检的健康志愿者为对照组。所有受试者均接受心脏彩超获得相关参数[左心房内径(LAD)、左心室舒张末期内径(LVEDD)、左心室收缩末期内径(LVESD)、左心室短轴缩短率(LVFS)、左心室后壁厚度(LVPWT)、室间隔厚度(IVST)、左心室射血分数(LVEF)、左心室舒张早期充盈峰最大充盈速度/舒张晚期充盈峰最大峰值速度(E/A)比值、Tei指数],分析心脏彩超相关参数与NYHA分级之间相关性。结果:观察组患者LAD、LVEDD、LVESD、LVPWT、IVST、Tei指数高于对照组(P0.05),LVFS、LVEF、E/A比值低于对照组(P0.05)。Tei指数随着NYHA分级增高而增高(P0.05),LVFS、LVEF、E/A比值随着NYHA分级增高而降低(P0.05)。Spearman秩相关分析结果显示,Tei指数与NYHA分级呈正相关(rs=0.398,P0.05),LVFS、LVEF、E/A比值与NYHA分级呈负相关(rs=-0.285,-0.442,-0.305,P0.05)。结论:高血压LVH伴左心衰竭患者发生明显左室肥厚和左心功能降低,心脏彩超可准确评估高血压LVH伴左心衰竭患者的心功能和病情严重程度,且部分心脏彩超相关参数与NYHA分级相关。  相似文献   

15.
Parallel measurements of breath-by-breath oxygen uptake, cardiac output (Doppler technique), blood pressure (Finapres technique) and heart rate were performed in nine subjects during cycle ergometer exercise in the upright and supine positions. Transients were monitored during power steps starting from and leading to either rest or lower levels of exercise intensity. Oxygen uptake (VO2) and cardiac output kinetics were markedly faster than in all other conditions when exercise was started from rest. In contrast to exercise-exercise on steps, the computed arteriovenous difference in O2 content increased almost immediately in this situation, indicating that not only the additional energy expenditure due to the acceleration of the flywheel but also an increased venous admixture from non-exercising parts of the body contributed to the early kinetics. The off kinetics generally showed a more uniform pattern and did not simply mirror the on transients. The present findings indicate that transitions from rest should be avoided when muscle VO2 kinetics are to be assessed on the basis of VO2 measurements at the mouth.  相似文献   

16.
摘要 目的:对比分析四维容积超声及彩色多普勒超声在胎儿肺静脉异位引流(APVC)诊断中的应用价值。方法:采用回顾性分析方法,2019年1月到2022年1月选择在本院进行诊治的胎儿肺静脉异位引流孕妇60例作为研究对象,都给予四维容积超声及彩色多普勒超声,记录影像学特征并判断诊断价值。结果:在60例孕妇中,彩色多普勒超声检查判断为胎儿肺静脉异位引流51例,诊断敏感性为85.0 %;四维容积超声检查判断为胎儿肺静脉异位引流59例,诊断敏感性为98.3 %,四维容积超声检查对胎儿肺静脉异位引流的诊断敏感性明显高于彩色多普勒超声检查(P<0.05)。彩色多普勒超声检查与四维容积超声检查诊断的特异性都为100.0%。在60例孕妇中,判断为胎儿肺静脉异位引流心上型32例,心下型28例;心上型的肺静脉引流途径为肺静脉-垂直静脉-右上腔静脉22例、肺静脉-垂直静脉-左上腔静脉10例,心下型的肺静脉引流途径为肺静脉-垂直静脉-左头臂静脉-右上腔静脉6例、肺静脉-垂直静脉-门静脉22例。合并心脏畸形32例,合并畸形率为53.3 %;有51例孕妇终止妊娠,9例孕妇继续妊娠,其中8例未经治疗者新生儿期死亡,1例在3月龄死亡。结论:相对于彩色多普勒超声,四维容积超声在胎儿肺静脉异位引流诊断中的应用可提高诊断敏感性,可有效反映肺静脉回流情况,可指导临床进行早期干预。  相似文献   

17.
Ascending aortic blood velocity was measured in the baboon (Papio ursinus) by using continuous wave Doppler ultrasound. The blood flow parameters thus obtained were compared to those by the standardized radionuclide technique. It appears that, due to the anatomical position of the ascending aorta and brachiocephalic trunks in relation to the ultrasound beam, Doppler ultrasound does not provide an accurate method of measuring aortic blood velocity in the baboon, which could be the reason for the poor correlation of the results from the two techniques.  相似文献   

18.
We present an evaluation of a novel technique for continuous (i.e., automatic) monitoring of relative cardiac output (CO) changes by long time interval analysis of a peripheral arterial blood pressure (ABP) waveform in humans. We specifically tested the mathematical analysis technique based on existing invasive and noninvasive hemodynamic data sets. With the former data set, we compared the application of the technique to peripheral ABP waveforms obtained via radial artery catheterization with simultaneous thermodilution CO measurements in 15 intensive care unit patients in which CO was changing because of disease progression and therapy. With the latter data set, we compared the application of the technique to noninvasive peripheral ABP waveforms obtained via a finger-cuff photoplethysmography system with simultaneous Doppler ultrasound CO measurements made by an expert in 10 healthy subjects during pharmacological and postural interventions. We report an overall CO root-mean-squared normalized error of 15.3% with respect to the invasive hemodynamic data set and 15.1% with respect to the noninvasive hemodynamic data set. Moreover, the CO errors from the invasive and noninvasive hemodynamic data sets were only mildly correlated with mean ABP (rho = 0.41, 0.37) and even less correlated with CO (rho = -0.14, -0.17), heart rate (rho = 0.04, 0.19), total peripheral resistance (rho = 0.38, 0.10), CO changes (rho = -0.26, -0.20), and absolute CO changes (rho = 0.03, 0.38). With further development and successful prospective testing, the technique may potentially be employed for continuous hemodynamic monitoring in the acute setting such as critical care and emergency care.  相似文献   

19.
Pulsewave velocity analysis is an option for the noninvasive determination of cardiac output and the evaluation of additional haemodynamic parameters. An algorithm we developed ourselves has been established as a method for the measurement of cardiac output in rabbits. The effectiveness of this program was investigated by monitoring controlled hypoxia-induced alterations in the circulatory system. Calculated values were compared with direct measurements of cardiac output with a Doppler flow probe placed in the ascending aorta. Within the physiological framework of blood gas analysis, a good correlation was found between the two methods. In the case of hypoxia-induced depression, however, the two methods showed diverging results, presumably due to arrhythmia-induced wave reflections within the arterial vascular tree. This makes an extension of the algorithm necessary to take account for these case.  相似文献   

20.
Arthritis is a chronic, debilitating disease affecting one in six people in the United States annually. One of the most promising surgical treatments is total joint replacement. After decades of development, some joint replacement (arthroplasty) systems such as the hip and knee enjoy high success rates while others, particularly newer ones for the ankle, have disappointing survival rates. The goal of this study was to investigate, develop, and test a methodology to assess implant osteointegration, specifically for the talar component of a total ankle prosthesis. A vibrometry technique using Doppler ultrasound was developed to non-invasively determine osteointegration clinically. This methodology was evaluated via preliminary experimentation, along with another validation methodology, to access whether design criteria have been met in order to initiate a clinical study of the technique. Bench-top and cadaveric testing demonstrated that the Doppler ultrasound technique could distinguish the level of osteointegration between loose and fixed implant components. The laser vibrometry technique, used for the validation of the ultrasound technique intraoperatively, was also shown to be functional and indicative of the ultrasound technique’s testing results. This methodology can provide a much needed tool to determine the integration of implants non-invasively in the clinical and surgical setting, thus allowing each patient’s rehabilitation program to be monitored and tailored to maximize the osteointegration and survival rate of their total joint replacement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号