首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
目的:探讨高分辨率核磁共振成像(magnetic resonance imaging,MRI)对颅内动脉粥样硬化斑块的诊断价值。方法:选择2016年1月至2018年6月在我院诊治的缺血性脑卒中患者134例作为研究对象,所有患者都给予数字减影血管造影(Digital subtraction angiography,DSA)与高分辨率MRI检查,记录颅内动脉粥样硬化斑块特征与分型,以DSA诊断为金标准,判断MRI的诊断价值(阳性预测值、特异度、灵敏度、阴性预测值)。结果:在134例患者中,高分辨率MRI显示未见斑块62例,Ⅰ型5例、Ⅱ型26例,Ⅲ型26例、Ⅳ型15例,与DSA诊结果一致124例,占比92.5%。高分辨率MRI与DSA诊断颅内动脉粥样硬化斑块的Kappa值为0.89,MRI对各分型的颅内动脉粥样硬化斑块的阳性预测值、特异度、灵敏度、阴性预测值分别为:Ⅰ型87.0%、99.2%、95.8%和99.2%,Ⅱ型81.0%、98.5%、83.4%和98.5%,Ⅲ型82.7%、82.7%、84.0%和95.7%,Ⅳ型100.0%、100.0%、100.0%和100.0%。结论:高分辨率MRI用于诊断颅内动脉粥样硬化斑块的价值与DSA检查有很好的一致性,可反映硬化斑块的分型。  相似文献   

2.
目的:评估和比较高分辨率计算机断层成像(high resolution computer tomography,HRCT)与磁共振成像(magnetic resonance imaging,MRI)对中耳胆脂瘤的诊断价值。方法:回顾性分析临床初步诊断为中耳胆脂瘤患者55人(63耳)在术前5天内进行的16排HRCT和1.5T MRI诊断结果,以病理诊断为基础对HRCT和MRI的诊断结果进行对比研究,统计分析HRCT和MRI的灵敏度、特异度、阳性预期值、阴性预期值,以及Kappa检验两者之间的内在观察一致性。结果:63耳中,病理确诊为中耳胆脂瘤40耳。HRCT正确诊断30例,假阳性11例,假阴性10例,灵敏度、特异度、阳性预期值以及阴性预期值分别为75%、52.17%、73.17%、54.55%。MRI正确诊断37例,假阳性和假阴性各为3例,灵敏度、特异度、阳性预期值以及阴性预期值分别为92.5%、86.96%、75%和86.96%。HRCT与MRI诊断结果之间的内在观察一致性Kappa=0.274(P0.05)。剔除既往有手术史的10耳,只针对无手术史的53耳,HRCT与MRI诊断结果之间的内在观察一致性增高,吻合度一般,Kappa=0.462(P0.05)。结论:MRI的总体阳性检出率高于HRCT,尤其是对中耳胆脂瘤手术后复发的诊断;HRCT与MRI两者相结合对于中耳胆脂瘤的明确诊断具有互补作用。  相似文献   

3.
BackgroundRupture of an atherosclerotic plaque is the primary cause of acute cardiovascular and cerebrovascular syndromes. Early and non-invasive detection of vulnerable atherosclerotic plaques (VP) would be significant in preventing some aspects of these syndromes. As a new contrast agent, dimercaptosuccinic acid (DMSA) modified ultra-small super paramagnetic iron oxide (USPIO) was synthesized and used to identify VP and rupture plaque by magnetic resonance imaging (MRI).MethodsAtherosclerosis was induced in male New Zealand White rabbits by feeding a high cholesterol diet (n = 30). Group A with atherosclerosis plaque (n = 10) were controls. VP was established in groups B (n = 10) and C (n = 10) using balloon-induced endothelial injury of the abdominal aorta. Adenovirus-carrying p53 genes were injected into the aortic segments rich in plaques after 8 weeks. Group C was treated with atorvastatin for 8 weeks. Sixteen weeks later, all rabbits underwent pharmacological triggering, and imaging were taken daily for 5 d after DMSA-USPIO infusion. At the first day and before being killed, serum MMP-9, sCD40L, and other lipid indicators were measured.ResultsDMSA-USPIO particles accumulated in VP and rupture plaques. Rupture plaques appeared as areas of hyper-intensity on DMSA-USPIO enhanced MRI, especially T2*-weighted sequences, with a signal strength peaking at 96 h. The group given atorvastatin showed few DMSA-USPIO particles and had lower levels of serum indicators. MMP-9 and sCD40L levels in group B were significantly higher than in the other 2 groups (P <0.05).ConclusionAfter successfully establishing a VP model in rabbits, DMSA-USPIO was used to enhance MRI for clear identification of plaque inflammation and rupture. Rupture plaques were detectable in this way probably due to an activating inflammatory process. Atorvastatin reduced the inflammatory response and stabilizing VP possibly by decreasing MMP-9 and sCD40L levels.  相似文献   

4.
Cerebral aspergillosis is associated with a significant morbidity and mortality rate. The imaging data present different patterns and no full consensus exists on typical imaging characteristics of the cerebral lesions. We reviewed MRI findings in 21 patients with cerebral aspergillosis and correlated them to the immune status of the patients and to neuropathological findings when tissue was available. The lesions were characterized by their number, topography, and MRI signal. Dissemination to the brain resulted from direct spread from paranasal sinuses in 8 patients, 6 of them being immunocompetent. Hematogenous dissemination was observed in 13 patients, all were immunosuppressed. In this later group we identified a total of 329 parenchymal abscesses involving the whole brain with a predilection for the corticomedullary junction. More than half the patients had a corpus callosum lesion. Hemorrhagic lesions accounted for 13% and contrast enhancement was observed in 61% of the lesions. Patients with hematogenous dissemination were younger (p = 0.003), had more intracranial lesions (p = 0.0004) and had a higher 12-week mortality rate (p = 0.046) than patients with direct spread from paranasal sinuses. Analysis of 12 aneurysms allowed us to highlight two distinct situations. In case of direct spread from the paranasal sinuses, aneurysms are saccular and located on the proximal artery portions, while the hematogenous dissemination in immunocompromised patients is more frequently associated with distal and fusiform aneurysms. MRI is the exam of choice for cerebral aspergillosis. Number and type of lesions are different according to the mode of dissemination of the infection.  相似文献   

5.

Background and Purpose

Longitudinal functional imaging studies of stroke are key in identifying the disease progression and possible therapeutic interventions. Here we investigate the applicability of real-time functional optoacoustic imaging for monitoring of stroke progression in the whole brain of living animals.

Materials and Methods

The middle cerebral artery occlusion (MCAO) was used to model stroke in mice, which were imaged preoperatively and the occlusion was kept in place for 60 minutes, after which optoacoustic scans were taken at several time points.

Results

Post ischemia an asymmetry of deoxygenated hemoglobin in the brain was observed as a region of hypoxia in the hemisphere affected by the ischemic event. Furthermore, we were able to visualize the penumbra in-vivo as a localized hemodynamically-compromised area adjacent to the region of stroke-induced perfusion deficit.

Conclusion

The intrinsic sensitivity of the new imaging approach to functional blood parameters, in combination with real time operation and high spatial resolution in deep living tissues, may see it become a valuable and unique tool in the development and monitoring of treatments aimed at suspending the spread of an infarct area.  相似文献   

6.

Background

Carotid endarterectomy (CEA) or stenting (CAS) are associated with a relatively low rate of clinical events, but diffusion-weighted imaging (DWI) is increasingly being used to compare the incidence of new ischemic lesions. Therefore, we conducted an updated meta-analysis on the occurrence of post-procedural new DWI lesions after CAS versus CEA.

Methods and Results

MEDLINE, Cochrane, ISI Web of Science and SCOPUS databases were searched and 20 studies (2 randomized and 18 non-randomized) with a total of 2104 procedures (CAS = 989; CEA = 1115) were included. The incidence of new DWI cerebral lesions was significantly greater after CAS than CEA (40.3% vs 12.2%; 20 studies; 2104 patients; odds ratio [OR] 5.17; 95% confidence interval [CI], 3.31-8.06; p<0.00001). Also peri-procedural stroke (17 studies; 1833 patients; OR 2.01; 95% CI, 1.14-3.55; p=0.02) and stroke or TIA (17 studies; 1833 patients; OR 2.40; 95% CI, 1.42-4.08; p=0.001) were significantly increased after CAS. This latter clinical advantage in the CEA group over CAS was tempered when CEA procedures were performed with shunting in all instead of selective shunting or when CAS was performed with only closed cell stents instead of both closed and open cell stents, however, no significant differences between subgroups emerged.

Conclusions

CAS is associated with an increased incidence of post-procedural brain DWI lesions. This greater amount of ischemic burden may also reflect a higher rate of cerebral events after CAS. However, whether recent technical advances mainly for CAS could potentially reduce these ischemic events still remains to be evaluated.  相似文献   

7.

Purpose

To minimize feature loss in T1- and T2-weighted MRI by merging multiple MR images acquired at different TR and TE to generate an image with increased dynamic range.

Materials and Methods

High Dynamic Range (HDR) processing techniques from the field of photography were applied to a series of acquired MR images. Specifically, a method to parameterize the algorithm for MRI data was developed and tested. T1- and T2-weighted images of a number of contrast agent phantoms and a live mouse were acquired with varying TR and TE parameters. The images were computationally merged to produce HDR-MR images. All acquisitions were performed on a 7.05 T Bruker PharmaScan with a multi-echo spin echo pulse sequence.

Results

HDR-MRI delineated bright and dark features that were either saturated or indistinguishable from background in standard T1- and T2-weighted MRI. The increased dynamic range preserved intensity gradation over a larger range of T1 and T2 in phantoms and revealed more anatomical features in vivo.

Conclusions

We have developed and tested a method to apply HDR processing to MR images. The increased dynamic range of HDR-MR images as compared to standard T1- and T2-weighted images minimizes feature loss caused by magnetization recovery or low SNR.  相似文献   

8.
目的:探讨3.0TMR高分辨磁敏感加权成像(SWI)序列对颅脑弥漫性轴索损伤(DAI)的诊断价值。方法:选择临床诊断为DAI的30例患者行SWI及常规序列扫描,观察患者病灶等,对比SWI与常规MR序列对DAI病灶形态、分布、数目显示的敏感性,并分析与哥拉斯哥昏迷(GCS)评分及预后的相关性。结果:130例DAI患者SWI序列平均病灶个数为22.83个,明显高于T1WI、T2WI、T2flair序列的1.5个、2.13个、4.1个,比较差异有统计学意义(X2=11.44,P<0.05);2SWI序列皮髓质交界区、白质区、基底节、脑干、小脑、胼胝体DAI病灶呈边界清晰、大小不等点状、片状、串珠状、条状、团状不均低信号;3GCS分值越高DAI平均病灶数目越少,两者呈明显负相关(r=-0.715,P<0.05);4痊愈、好转、死亡患者DAI平均病灶数目、脑中线累及率依次增高,比较差异有统计学意义(F=9.29,X2=13.52,P<0.05)。结论:3.0TMR高分辨SWI序列对DTI的敏感性优于常规序列,病灶数目与GCS评分具有相关性,能够较好地预测患者预后情况。  相似文献   

9.
动脉粥样硬化分子影像学通过使用具有敏感性和特异性影像对比的分子探针针对动脉粥样硬化斑块相关的特定分子进行分子成像.该方法会极大地提高对动脉粥样硬化病变特性的检测水平和增强对该病变特征,尤其对斑块的组成成份的识别能力.斑块的组成成份和斑块的破裂、斑块的易损性以及斑块破裂后导致的结果密切相关.因此了解斑块组成成份的在体无创性检测将对动脉粥样硬化病人的治疗和判断预后产生非常重要的临床应用价值.  相似文献   

10.

Objective

To assess the feasibility of renal proton magnetic resonance spectroscopy for quantification of triglyceride content and to compare spectral quality and reproducibility without and with respiratory motion compensation in vivo.

Materials and Methods

The Institutional Review Board of our institution approved the study protocol, and written informed consent was obtained. After technical optimization, a total of 20 healthy volunteers underwent renal proton magnetic resonance spectroscopy of the renal cortex both without and with respiratory motion compensation and volume tracking. After the first session the subjects were repositioned and the protocol was repeated to assess reproducibility. Spectral quality (linewidth of the water signal) and triglyceride content were quantified. Bland-Altman analyses and a test by Pitman were performed.

Results

Linewidth changed from 11.5±0.4 Hz to 10.7±0.4 Hz (all data pooled, p<0.05), without and with respiratory motion compensation respectively. Mean % triglyceride content in the first and second session without respiratory motion compensation were respectively 0.58±0.12% and 0.51±0.14% (P = NS). Mean % triglyceride content in the first and second session with respiratory motion compensation were respectively 0.44±0.10% and 0.43±0.10% (P = NS between sessions and P = NS compared to measurements with respiratory motion compensation). Bland-Altman analyses showed narrower limits of agreement and a significant difference in the correlated variances (correlation of −0.59, P<0.05).

Conclusion

Metabolic imaging of the human kidney using renal proton magnetic resonance spectroscopy is a feasible tool to assess cortical triglyceride content in humans in vivo and the use of respiratory motion compensation significantly improves spectral quality and reproducibility. Therefore, respiratory motion compensation seems a necessity for metabolic imaging of renal triglyceride content in vivo.  相似文献   

11.
磁共振波谱分析在颅脑胶质瘤分级中的应用研究   总被引:1,自引:0,他引:1  
目的 分析脑胶质瘤的氢质子磁共振波谱(proton magnetic resonance spectroscopy,1H-MRS)表现及其临床意义;探讨脑胶质瘤的1H-MRS特点与其病理级别相关性.方法 搜集经临床手术、病理证实的脑胶质瘤病例49例,按照WHO诊断标准分成两组:低级别脑胶质瘤组、高级别脑胶质瘤组.所有患者在术前行1H-MRs检查,均在MR非增强成像的基础上获得.使用Philips Achieva 1.5T超导磁共振扫描仪,单体素或多体素扫描,点分辨法,检测不同区域代谢物变化.结果 脑胶质瘤的1H-MRS表现:肌酸(Cr)轻度下降,N-乙酰天门冬氨酸(NAA)显著下降,胆碱(Cho)显著增高.低、高级别脑胶质瘤的肿瘤组织与对侧止常脑组织的NAA、Cho、NAA/Cr、NAA/Cho值存在显著性差异(P〈0.05);低级别和高级别脑胶质瘤的肿瘤组织的NAA/Cr、NAA/Cho值存在显著性差异(P〈0.05).脑胶质瘤的NAA/Cho、Cho/Cr、NAA/Cr值与病理级别相关,其中NAA/Cho和NAA/Cr值反映肿瘤级别较稳定;NAA/Cr、NAA/Cho值呈负相关关系,Cho/Cr值呈正相关关系.结论 :1H-MRS结合MKI能提高脑胶质瘤术前诊断的准确性.1H-MRS能对胶质瘤进行分级,反映胶质瘤代谢特性以及肿瘤生长潜能.  相似文献   

12.
Autism spectrum disorders (ASD) comprise an etiologically heterogeneous set of neurodevelopmental disorders. Neuroligin-3 (NL-3) is a cell adhesion protein that mediates synapse development and has been implicated in ASD. We performed ex-vivo high resolution magnetic resonance imaging (MRI), including diffusion tensor imaging (DTI) and behavioral (social approach and zero maze) tests at 3 different time points (30, 50 and 70 days-of-age) on NL-3 and wild-type littermates to assess developmental brain abnormalities in NL-3 mice. MRI data were segmented in 39 different gray and white matter regions. Volumetric measurements, along with DTI indices from these segmented regions were also performed. After controlling for age and gender, the NL-3 knock-in animals demonstrated significantly reduced sociability and lower anxiety-related behavior in comparison to their wild type littermates. Significantly reduced volume of several white and gray matter regions in the NL-3 knock-in mice were also observed after considering age, gender and time point as covariates. These findings suggest that structural changes in the brain of NL-3 mice are induced by the mutation in the NL-3 gene. No significant differences in DTI indices were observed, which suggests that the NL-3 mutation may not have a profound effect on water diffusion as detected by DTI. The volumetric and DTI studies aid in understanding the biology of disrupting function on an ASD risk model and may assist in the development of imaging biomarkers for ASD.  相似文献   

13.
14.
15.
PurposeMR might be well suited to obtain reproducible and accurate measures of fat tissues in infants. This study evaluates MR-measurements of adipose tissue in young infants in vitro and in vivo.ResultsIn vitro accuracy errors depended on the chosen segmentation procedure, ranging from 5.4% to 76%, while the sequence showed no significant influence. Artificial breathing increased the minimal accuracy error to 9.1%. In vivo reproducibility errors for total fat volume of the sleeping infants ranged from 2.6% to 3.4%. Neither segmentation nor sequence significantly influenced reproducibility.ConclusionWith both cartesian and PROPELLER sequences an accurate and reproducible measure of body fat was achieved. Adequate segmentation was mandatory for high accuracy.  相似文献   

16.

Purpose

To evaluate the intra- and inter-observer variability of the North American Symptomatic Carotid Endarterectomy Trial (NASCET) and Warfarin-Aspirin Symptomatic Intracranial Disease (WASID) criteria for the evaluation of middle cerebral artery (MCA) stenosis using digital subtraction angiography (DSA).

Materials and Methods

DSA images of 114 cases with 131 stenotic MCAs were retrospectively analyzed. Two radiologists and a researcher measured the degree of MCA stenosis independently using both NASCET and WASID methods. To determine intra-observer agreement, all the observers reevaluated the degree of MCA stenosis 4 weeks later. The linear relation and coefficient of variation (CV) between the measurements made by the two methods were assessed by correlation coefficient and multi-factor analysis of variance (ANOVA), respectively. Intra- and inter-observer variability of the two methods was evaluated by intraclass correlation coefficient (ICC), Spearman’s R value, Pearson correlation coefficient and Bland-Altman plots.

Results

Despite the fact that the degree of MCA stenosis measured by NASCET was lower than measured using the WASID method, there was good linear correlation between the measurements made by the two methods (for the mean measurements of the 3 observers, NASCET% = 0.891 × WASID% - 1.89%; ICC, Spearman’s R value and Pearson correlation were 0.874, 0.855, and 0.874, respectively). The CVs of both intra- and inter-observer measurements of MCA stenosis using WASID were significantly lower than that using NASCET confirmed by the multi-factor ANOVA results, which showed only the measurement methods of MCA stenosis had significant effects on the CVs both in intra- and inter-observer measurements (both P values < 0.001). Intra-observer measurements showed good or excellent agreement with respect to WASID and NASCET evaluation (ICC, 0.656 to 0.817 and 0.635 to 0.761, respectively). Good agreement for the WASID evaluation (ICC, 0.592 to 0.628) and for the NASCET evaluation (ICC, 0.529 to 0.568) was observed for inter-observer measurements. Bland-Altman plots demonstrated that the WASID method had better reproducibility and intra-observer agreement than NASCET method for evaluating MCA stenosis.

Conclusion

Both NASCET and WASID methods have an acceptable level of agreement; however, the WASID method had better reproducibility for the evaluation of MCA stenosis, and thus the WASID method may serve as a standard for measuring the degree of MCA stenosis.  相似文献   

17.
A novel method is described for mapping dynamic cerebral blood flow autoregulation to assess autoregulatory efficiency throughout the brain, using magnetic resonance imaging (MRI). Global abnormalities in autoregulation occur in clinical conditions, including stroke and head injury, and are of prognostic significance. However, there is limited information about regional variations. A gradient-echo echo-planar pulse sequence was used to scan the brains of healthy subjects at a rate of 1 scan/second during a transient decrease in arterial blood pressure provoked by a sudden release of pressure in bilateral inflated thigh cuffs. The signal decrease and subsequent recovery were analyzed to provide an index of autoregulatory efficiency (MRARI). MRI time-series were successfully acquired and analyzed in eleven subjects. Autoregulatory efficiency was not uniform throughout the brain: white matter exhibited faster recovery than gray (MRARI = 0.702 vs. 0.672, p = 0.009) and the cerebral cortex exhibited faster recovery than the cerebellum (MRARI = 0.669 vs. 0.645, p = 0.016). However, there was no evidence for differences between different cortical regions. Differences in autoregulatory efficiency between white matter, gray matter and the cerebellum may be a result of differences in vessel density and vasodilation. The techniques described may have practical importance in detecting regional changes in autoregulation consequent to disease.  相似文献   

18.
19.
目的:分析磁共振氢质子磁共振波谱(Proton Magnetic Resonance Spectroscopy,1H-MRS)的特征与脑胶质瘤病理分级的相关性,探讨氢质子磁共振波谱及常规磁共振成像(Magnetic Resonance Imaging,MRI)联合应用在提高脑胶质瘤的临床诊断中的应用价值.方法:脑胶质瘤(经临床手术证实及病理诊断确诊)患者34例,参照国际卫生组织诊断标准,分为低级别胶质瘤组及高级别胶质瘤组.其中,低级别组16例,高级别组18例,在行常规MRI检查的同时,配合1H-MRS检查,测NAA(N-乙酰天门冬氨酸)、Cho(胆碱)、Cr(肌酸)值,在不同级别胶质瘤、同级别胶质瘤不同位置的代谢物进行综合分析.结果:在获得常规MRI图像并进行诊断后,进行氢质子磁共振波谱检测分析:在低级别胶质瘤及高级别胶质瘤患者中,Cr(肌酸)的总量变化不大,有轻度的下降;而NAA(N-乙酰天门冬氨酸)下降程度较为明显;Cho(胆碱)则明显升高.低级别胶质瘤及高级别胶质瘤患侧的肿瘤组织同对侧的正常脑组织的各种代谢物及其比值(Cho、NAA、NAA/Cho、NAA/Cr值)具有显著性差异(P<0.05);低级别胶质瘤及高级别胶质瘤的肿瘤组织的代谢物比值NAA/Cr、NAA/Cho值差异具有显著性(P<0.05).低级别胶质瘤及高级别胶质瘤的Cho/Cr、NAA/Cho、NAA/Cr值与脑胶质瘤的病理分级具有相关性;在各个比值中,NAA/Cr与NAA/Cho值能够较好地反映脑胶质瘤的病理分级,二者的值呈现负相关;Cho/Cr值呈正相关.结论:常规MRI联合1H-MRS在脑胶质瘤的诊断中,能够有效提高准确性,在临床评估脑胶质瘤的分级、确定范围和鉴别诊断都具有重要的指导作用.  相似文献   

20.

Purpose

Volume flow rate (VFR) measurements based on phase contrast (PC)-magnetic resonance (MR) imaging datasets have spatially varying bias due to eddy current induced phase errors. The purpose of this study was to assess the impact of phase errors in time averaged PC-MR imaging of the cerebral vasculature and explore the effects of three common correction schemes (local bias correction (LBC), local polynomial correction (LPC), and whole brain polynomial correction (WBPC)).

Methods

Measurements of the eddy current induced phase error from a static phantom were first obtained. In thirty healthy human subjects, the methods were then assessed in background tissue to determine if local phase offsets could be removed. Finally, the techniques were used to correct VFR measurements in cerebral vessels and compared statistically.

Results

In the phantom, phase error was measured to be <2.1 ml/s per pixel and the bias was reduced with the correction schemes. In background tissue, the bias was significantly reduced, by 65.6% (LBC), 58.4% (LPC) and 47.7% (WBPC) (p < 0.001 across all schemes). Correction did not lead to significantly different VFR measurements in the vessels (p = 0.997). In the vessel measurements, the three correction schemes led to flow measurement differences of -0.04 ± 0.05 ml/s, 0.09 ± 0.16 ml/s, and -0.02 ± 0.06 ml/s. Although there was an improvement in background measurements with correction, there was no statistical difference between the three correction schemes (p = 0.242 in background and p = 0.738 in vessels).

Conclusions

While eddy current induced phase errors can vary between hardware and sequence configurations, our results showed that the impact is small in a typical brain PC-MR protocol and does not have a significant effect on VFR measurements in cerebral vessels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号