首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
IntroductionThe AcQMap High Resolution Imaging and Mapping System was recently introduced. This system provides 3D maps of electrical activation across an ultrasound-acquired atrial surface.MethodsWe evaluated the feasibility and the acute and short-term efficacy and safety of this novel system for ablation of persistent atrial fibrillation (AF) and atypical atrial flutter.ResultsA total of 21 consecutive patients (age (mean ± standard deviation) 62 ± 8 years, 23% female) underwent catheter ablation with the use of the AcQMap System. Fourteen patients (67%) were treated for persistent AF and 7 patients (33%) for atypical atrial flutter. Eighteen patients (86%) had undergone at least one prior ablation procedure. Acute success, defined as sinus rhythm without the ability to provoke the clinical arrhythmia, was achieved in 17 patients (81%). At 12 months, 4 patients treated for persistent AF (29%) and 4 patients treated for atypical flutter (57%) remained in sinus rhythm. Complications included hemiparesis, for which intra-arterial thrombolysis was given with subsequent good clinical outcome (n = 1), and complete atrioventricular block, for which a permanent pacemaker was implanted (n = 2). No major complications attributable to the mapping system occurred.ConclusionThe AcQMap System is able to provide fast, high-resolution activation maps of persistent AF and atypical atrial flutter. Despite a high acute success rate, the recurrence rate of persistent AF was relatively high. This may be due to the selection of the patients with therapy-resistant arrhythmias and limited experience in the optimal use of this mapping system that is still under development.Supplementary InformationThe online version of this article (10.1007/s12471-021-01636-w) contains supplementary material, which is available to authorized users.  相似文献   

3.
Recent reports have described the incidence of atrioesophageal fistulas (AEF), often resulting in death, from radiofrequency (RF) catheter ablation of atrial fibrillation (AF).1 Cases of esophageal perforation without concomitant AEF have not been described as extensively.1 The precise mechanisms leading to esophageal injury after catheter ablation without involvement of the left atrium are not fully understood. The surgical approach to treat esophageal perforation is strongly recommended.2 However, a unified surgical treatment approach has not yet been established. We describe a case of successful surgical repair of an esophageal perforation after ablation using surgical repair in combination with an omental wrap.  相似文献   

4.

Objective

To assess the outcome and associated risks of atrial defragmentation for the treatment of long-standing persistent atrial fibrillation (LSP-AF).

Methods

Thirty-seven consecutive patients (60.4 ± 7.3 years; 28 male) suffering from LSP-AF who underwent pulmonary vein isolation (PVI) and linear ablation were compared. All patients were treated with the Stereotaxis magnetic navigation system (MNS). Two groups were distinguished: patients with (n = 20) and without (n = 17) defragmentation. The primary endpoint of the study was freedom of AF after 12 months. Secondary endpoints were AF termination, procedure time, fluoroscopy time and procedural complications. Complications were divided into two groups: major (infarction, stroke, major bleeding and tamponade) and minor (fever, pericarditis and inguinal haematoma).

Results

No difference was seen in freedom of AF between the defragmentation and the non-defragmentation group (56.2 % vs. 40.0 %, P = 0.344). Procedure times in the defragmentation group were longer; no differences in fluoroscopy times were observed. No major complications occurred. A higher number of minor complications occurred in the defragmentation group (45.0 % vs. 5.9 %, P = 0.009). Mean hospital stay was comparable (4.7 ± 2.2 vs. 3.4 ± 0.8 days, P = 0.06).

Conclusion

Our study suggests that complete defragmentation using MNS is associated with a higher number of minor complications and longer procedure times and thus compromises efficiency without improving efficacy.  相似文献   

5.
Contact force (CF) is one of the major determinants for sufficient lesion formation. CF-guided procedures are associated with enhanced lesion formation and procedural success. We report our initial experience in epicardial ventricular tachycardia (VT) ablation with a force-sensing catheter using a new approach with an angioplasty balloon. Two patients with arrhythmogenic right ventricular cardiomyopathy who underwent prior unsuccessful endocardial ablation were treated with epicardial VT ablation. CF data were used to titrate force, power and ablation time.  相似文献   

6.
A case of macro-reentrant tachycardia associated with a box lesion after thoracoscopis left atrial surgical atrial fibrillation (AF) ablation yet to be described. The goal was to clarify the mechanisms and electrophysiological characteristics of this type of tachycardia.A patient was admitted for an EP study following surgical thoracoscopic AF ablation (box lexion formation by right-sided Cobra thoracoscopic ablation). Thoracoscopic ablation was done as the first step of the hybrid ablation approach to the persistent AF; the second step was the EP study. At the EP study, he presented with incessant regular tachycardia (cycle length of 226 ms). An EP study with conventional, 3D activation and entrainment mapping was done to assess the tachycardia mechanism. Two conduction gaps in the superior line (roofline) between the superior pulmonary veins were discovered. The tachycardia was successfully treated with a radiofrequency application near the gap close to the left superior pulmonary vein; however, following tachycardia termination, pulmonary vein isolation was absent. A second radiofrequency application, close to the roof of the right superior pulmonary, vein closed the gap in the box and led to the isolation of all 4 pulmonary veins. No atrial tachycardia recurred during the 6-month follow-up.Conduction gaps in box lesion created by thoracospcopic ablation can present as a novel type of man-made tachycardia after surgical ablation of atrial fibrillation. Activation and entrainment mapping is necessary for an accurate diagnosis.  相似文献   

7.
Abstract

To investigate the effects of fat layer on the temperature distribution during microwave atrial fibrillation catheter ablation in the conditions of different ablation time; 3D finite element models (fat layer and no fat layer) were built, and temperature distribution was obtained based on coupled electromagnetic-thermal analysis at 2.45?GHz and 30?W of microwave power. Results shown: in the endocardial ablation, the existence of the fat layer did not affect the shape of the 50?°C contour before 30?s. The increase speed of depth became quite slowly in the model with fat layer after 30?s. When ablation depth needed fixed, there are no significant effect on effectively ablation depth whether fat layer over or not. However, the existence of fat layer makes the temperature lower in the myocardium, and maximum temperature point closer to the myocardium surface. What is more, in the model with fat layer, effective ablation reach lower maximum temperature and the shallower depth of 50?°C contour. But there are larger ablation axial length and transverse width. In this case, doctor should ensure safety of normal cardiac tissue around the target tissue. In the epicardial ablation, the existence of fat layer seriously affects result of the microwave ablation. The epicardial ablation needs more heating time to create lesion. But epicardial ablation can be better controlled in the shape of effective ablation area because of the slowly increase of target variables after the appearing of 50?°C contour. Doctor can choose endocardial or epicardial ablation in different case of clinic requirement.  相似文献   

8.
BackgroundCurrently, cryoballoon (CB) thawing after single stop is generally performed. Previous research had reported that long thawing time using a single stop affects pulmonary veins tissue injury. However, it is uncertain whether CB thawing after single stop affects clinical outcomes.ObjectiveThis study aimed to clarify clinical significance of CB thawing in patients with paroxysmal atrial fibrillation.MethodsTwo hundred ten patients with paroxysmal atrial fibrillation who underwent CB from January 2018 to October 2019 were analyzed. We compared the clinical outcomes of patients whose CB applications were completely stopped with only the double stop technique (DS group, n = 99) and patients with single stop (SS group, n = 111). In DS group, we performed double stop technique for all CB application regardless of phrenic nerve injury or the temperature of esophagus.ResultsThe atrial arrhythmia free-survival rate at 2 years after CB was significantly lower for the DS group than the SS group (76.8% vs 87.4%; p = 0.045). Complications occurred in 2 patients from the DS group and no complications were observed in patients from the SS group (p = 0.13). Mean procedural time was shorter in the DS group than in the SS group (53.1 vs 58.1 min; p = 0.046)ConclusionDS group had higher recurrence rate than SS group. There was no significant difference regarding safety between both the groups. We found that the thawing process after single stop is very important for CB application.  相似文献   

9.
IntroductionProspective studies on rivaroxaban and apixaban have shown the safety and efficacy of direct anticoagulation agents (DOAC)s used peri-procedurally during radiofrequency ablation (RFA) of atrial fibrillation (AF). Studies comparing the two agents have not been performed.MethodsConsecutive patients from a prospective registry who underwent RFA of AF between April 2012 and March 2015 and were on apixaban or rivaroxaban were studied. Clinical variables and outcomes were noted.ResultsThere were a total of 358 patients (n = 56 on apixaban and n = 302 on rivaroxaban). There were no differences in baseline characteristics between both groups. The last dose of rivaroxaban was administered the night before the procedure in 96% of patients. In patients on apixaban, 48% of patients whose procedure was in the afternoon took the medication on the morning of the procedure. TIA/CVA occurred in 2 patients (0.6%) in rivaroxaban group with none in apixaban group (p = 0.4). There was no difference in the rate of pericardial effusion between apixaban and rivaroxaban groups [1.7% vs 0.6% (p = 0.4)]. Five percent of patients in both groups had groin complications (p = 0.9). In apixaban group, all groin complications were small hematomas except one patient who had a pseudoaneurysm (1.6%). One pseudo-aneurysm, 1 fistula and 3 large hematomas were noted in patients on rivaroxaban (1.7%) with the rest being small hematomas. DOACs were restarted post procedure typically 4 h post hemostasis.ConclusionsPeri-procedural uninterrupted use of apixaban and rivaroxaban during AF RFA is safe and there are no major differences between both groups.  相似文献   

10.
A 60-year-old man presented with sustained supraventricular tachycardia. Atrial tachycardia (AT), with the earliest atrial activation (EAA) occurring at the ostium of the coronary sinus, was reproducibly induced.Three-dimensional electroanatomical mapping (3DEAM) using a 3.5-mm distal electrode tip linear catheter (Thermocool) and radiofrequency energy (RF) was performed at the fractionated atrial electrogram site. It preceded at 30 ms to the EAA but did not terminate AT. Further 3DEAM using a multielectrode mapping catheter (Pentaray) demonstrated a centrifugal propagation pattern at the boundary zone between the right atrium and inferior vena cava. RF application here terminated AT, which then became non-inducible.  相似文献   

11.

Introduction

Catheter ablation of longstanding (> 1 year) persistent atrial fibrillation (AF) is associated with poor outcome. This might be due to remodelling and fibrosis formation, mainly located in the posterior left atrial (LA) wall. Therefore, we adopted a thoracoscopic epicardial box isolation of the posterior left atrium using bipolar RF energy with intraoperative testing of conduction block.

Methods and results

Bilateral thoracoscopic box isolation was performed with a bipolar RF clamp. Entrance block was defined as absence of a conducted electrogram within the box, while exit block was confirmed by pacing at 10.0 V/2 ms. Ablation outcome was evaluated after 3, 6, 12 and 24 months with 12-lead ECGs and 24-hour Holter recordings.Twenty-five consecutive patients were included (58 ± 7 years, persistent AF duration 1.8 ± 0.9 years). Entrance block was achieved in all patients and exit block confirmed if sinus rhythm was achieved. After 17 ± 7 months, 76 % of the patients (n = 19) were free of AF recurrence. One patient died within 1 month and was considered an ablation failure. Four patients with AF recurrences regained sinus rhythm with additional catheter ablation or antiarrhythmic drugs.

Conclusions

Treatment of longstanding persistent AF with thoracoscopic epicardial LA posterior box isolation using bipolar RF energy with intraoperative testing of conduction block is feasible and highly effective.  相似文献   

12.
Convergent atrial fibrillation ablation involves extensive epicardial as well as endocardial ablation of the left atrium. We examined whether it changes the morphology of the surface P wave. We reviewed electrocardiograms of 29 patients who underwent convergent ablation for atrial fibrillation. In leads V1, II and III, we measured P wave duration, area and amplitude before ablation, and at 1, 3 and 6 months from ablation.After ablation, there were no significant changes in P wave amplitude, area, or duration in leads II and III. There was a significant reduction in the area of the terminal negative deflection of the P wave in V1 from 0.38 mm2 to 0.13 mm2 (p = 0.03). There is also an acute increase in the amplitude and duration of the positive component of the P wave in V1 followed by a reduction in both by 6 months. Before ablation, 62.5% of the patients had biphasic P waves in V1. In 6 months, only 39.2% of them had biphasic P waves.Hybrid ablation causes a reduction of the terminal negative deflection of the P wave in V1 as well as temporal changes in the duration and amplitude of the positive component of the P wave in V1. This likely reflects the reduced electrical contribution of the posterior left atrium after ablation as well as anatomical and autonomic remodeling. Recognition of this altered sinus P wave morphology is useful in the diagnosis of atrial arrhythmias in this patient population.  相似文献   

13.
IntroductionThe efficacy of catheter ablation in patients with low cardiac function has been previously reported; however, only a few studies have included mid-range ejection fraction (mrEF). This study aimed to evaluate the efficacy and safety of atrial fibrillation (AF) ablation in patients with left ventricular ejection fraction (LVEF) < 50%.MethodsThis study retrospectively analyzed 79 patients (reduced ejection fraction [rEF]/mrEF, 38/41; paroxysmal/persistent, 37/42; heart failure hospitalizations within one year before ablation, 36 [45.6%]) who underwent the first ablation procedure at our hospital from April 2017 to December 2021. Radiofrequency ablation and cryoablation were performed for 69 and 10 patients, respectively.ResultsComplications included pacemaker implantation for postoperative sick sinus syndrome in one patient and inguinal hematoma in one patient. Regarding efficacy, there were significant postoperative improvements in echocardiographic data, blood test values, and diuretic use. After a mean follow-up of 60 months, 86.1% patients had no AF recurrence. There were 9 heart failure hospitalizations (11.4%) and 5 all-cause deaths (6.3%); no significant differences were found between the rEF and mrEF groups. No significant predictors of AF recurrence were found in preoperative patient characteristics.ConclusionAF ablation in patients with LVEF <50% significantly improved cardiac and renal functions with few complications, resulting in a high non-recurrence rate and reduced heart failure.  相似文献   

14.
The inability of current catheter ablation procedures to accurately monitor lesion formation limits their safety and efficacy. An advanced fully integrated radiofrequency (RF)/optical coherence tomography (OCT) ablation catheter is developed, which enables real-time monitoring during ablation. An OCT fiber array is especially designed, developed and integrated into an off-the-shelf irrigated RF ablation catheter. In-vitro experimental studies performed on poultry and ovine hearts demonstrate the ability of the integrated RF/OCT system to provide information on the quality and orientation of catheter/wall contact. Experimental results show that adipose tissue can be accurately identified from normal myocardial tissue with 94% accuracy and lesion formation is monitored with an overall accuracy of 93%. The ability to predict pop events is also demonstrated, with an accuracy of 86%.  相似文献   

15.
IntroductionThe endoscopic laser balloon ablation system (EAS) is a relatively novel technique to perform pulmonary vein isolation (PVI) in the treatment of atrial fibrillation (AF). The present study aimed to report the results of the first 50 patients treated in the Netherlands with the EAS in terms of procedural characteristics and AF-free survival.MethodsFifty patients successfully underwent EAS PVI. Median follow-up was 17 months. Mean age was 56 years, 82 % had paroxysmal AF.Results99 % of the pulmonary veins were successfully isolated with the EAS. Mean procedure time was 171 min and mean fluoroscopy time was 36 min. One procedure was complicated by a temporary phrenic nerve palsy (2 %). During follow-up, 58 % of patients remained free of AF without the use of antiarrhythmic drugs.ConclusionPVI with EAS is associated with a low risk of complications and a medium-term AF-free survival comparable with other PVI techniques.

Electronic supplementary material

The online version of this article (doi:10.1007/s12471-014-0624-y) contains supplementary material, which is available to authorized users.  相似文献   

16.
The important increase in life expectancy of adult patients with congenital heart disease (ACHD) has generated new challenges, including arrhythmias that represent one of the main late complications. Reentrant atrial arrhythmias are by far the main mechanism encountered, and catheter ablation has been now presented as a first-line therapy in this patient population. The number of procedures is expected to continuously increase year after year. The heterogeneity and complexity of phenotypes encountered require these cases to be performed by highly experienced operators, in specialized centers with multidisciplinary competencies. A thorough knowledge and understanding of anatomic specificities, vascular access issues, and main circuits encountered according to underlying phenotype is essential. Acute success rates have significantly improved and are now excellent, but recurrences remain a common issue, with different mechanisms or circuits frequently encountered. Observational data have suggested the interest of systematically targeting all inducible atrial arrhythmias, whether previously documented or not, and a lot of hope and research is based on the prediction of arrhythmia substrate before arrhythmia development by imaging or electroanatomic mapping to deliver a prophylactic patient tailored ablation approach. In this review, we summarize those different points in the most common or distinctive defects to offer a didactic overview of atrial flutter catheter ablation in ACHD patients.  相似文献   

17.
IntroductionAblation remains a modality of choice in select patients with Atrial fibrillation (AF). Which is done via a surgical or catheter-based approach.ObjectiveThis meta-analysis aimed to compare the efficacy of Surgical and Catheter ablation in the management of AF.MethodsElectronic search on PubMed (MEDLINE), EBSCO, EuropePMC, Clinicaltrials.gov, and Google Scholar was done. Studies comparing the use of surgical or catheter ablation in patients with AF were included. The Primary outcome of interest was Arrhythmia free patients at 12 months post-ablation.ResultsEight studies (744 patients) reported a statistically significant difference in Arrhythmia recurrence rate between surgical and catheter-based ablation. The pooled hazard ratio was chosen to compare the risk of AF recurrence between these groups with pooled Hazard ratio comparing surgical to catheter approach of 0.40 [0.35,0.45], p < 0.001 favoring surgical approach; low heterogeneity I2 22%, p = 0.25. Meta-analyses were also performed on procedural time, length of stay and major adverse events.ConclusionThe increased rate of adverse effects and length of hospitalization impedes the implementation of surgical ablation as primary ablation method of AF in general. However, the result of our meta-analysis shows the promising result of surgical ablation compared to catheter-based ablation.  相似文献   

18.
Focal point-by-point radiofrequency catheter ablation has shown considerable success in the treatment of paroxysmal atrial fibrillation. However, it is not without limitations. Recent clinical and preclinical studies have demonstrated that cryothermal ablation using a balloon catheter (Artic Front©, Medtronic CryoCath LP) provides an effective alternative strategy to treating atrial fibrillation. The objective of this article is to review efficacy and safety data surrounding cryoballoon ablation for paroxysmal and persistent atrial fibrillation. In addition, a practical step-by-step approach to cryoballoon ablation is presented, while highlighting relevant literature regarding: 1) the rationale for adjunctive imaging, 2) selection of an appropriate cryoballoon size, 3) predictors of efficacy, 4) advanced trouble-shooting techniques, and 5) strategies to reduce procedural complications, such as phrenic nerve palsy.  相似文献   

19.
BackgroundThere are limited data describing the experience of radiofrequency (RF) vs. cryoballoon (CB) ablation for atrial fibrillation (AF) among elderly patients in the United States.MethodsWe conducted a retrospective analysis of patients ≥75 years of age undergoing index RF vs. CB ablation between January 2014 and May 2020 at our center. The choice of ablation technique was left to the operator's discretion. Major complications and efficacy, defined as freedom from any atrial tachyarrhythmia (ATA) lasting ≥30 s after one year of follow-up, were assessed in patients with index RF vs. CB ablation.ResultsIn our cohort of 186 patients, the median age was 78 (76–81) years, 54.8% were men, and 39.2% had persistent AF. The median CHA2DS2-VASc score was 4 (3–4), while the median duration of AF was 3 (1–7) years. The majority (n = 112, 60.2%) underwent RF ablation. The median procedure time was significantly lower in CB group (197 vs 226.5 min, p=<0.01). The incidence of complications was similar in the two sub-groups (RF: 1.8% vs. CB: 2.7%, p = 0.67). Similarly, arrhythmia-free survival rate on antiarrhythmic drugs at 1-year follow-up remained statistically comparable (63.4% vs. 68.9%, p = 0.33) between patients receiving RF vs. CB ablation.ConclusionThe safety and efficacy of RF vs. CB ablation for AF remained comparable in our cohort of patients older than 75 years. CB ablation was associated with a shorter procedure time.  相似文献   

20.
BackgroundThe new version of inner lumen mapping catheter (Achieve Advance?; Medtronic, Minnesota, USA) includes a new solid core which provides improved rotational response, as compared to the current Achieve Mapping Catheter. In the present study, we sought to analyze the rate of visualisation of real-time recordings using this new device comparing it with a large cohort of patients having undergone second generation cryoballoon (CB) ablation using the previous Achieve mapping catheter.MethodsAll patients having undergone CB ablation using the Achieve Advance and the last 150 consecutive patients having undergone CB ablation using the previous Achieve were analysed. Exclusion criteria were presence of an intracavitary thrombus, uncontrolled heart failure, moderate or severe valvular disease and contraindications to general anesthesia.ResultsA total of 200 consecutive patients (60.1 ± 9.5 years, 75% males) were evaluated (50 Achieve Advance and 150 old Achieve). Real-time recordings were significantly more prevalent in the “new Achieve Advance” population compared with the “old Achieve” group (73.5% vs 56.8%; p = 0.0001). Real-time recordings could be more frequently visualized in the “Achieve Advance” group in all veins except RIPV (LSPV: 86% vs 71.3%, p = 0.04; LIPV: 84% vs 62.7%, p = 0.005; RSPV: 78% vs 52%, p < 0.0001; RIPV: 46% vs 41.3%, p = 0.3).ConclusionsThe rate of visualisation of real-time recordings is significantly higher using the new Achieve Advance if compared to the previous Achieve mapping catheter in the setting of CB ablation. Real-time recordings can be visualized in approximately 73.5% of veins with this new device.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号