首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Zebrafish are a proven model for vision research, however many of the earlier methods generally focused on larval fish or demonstrated a simple response. More recently adult visual behavior in zebrafish has become of interest, but methods to measure specific responses are new coming. To address this gap, we set out to develop a methodology to repeatedly and accurately utilize the optokinetic response (OKR) to measure visual acuity in adult zebrafish. Here we show that the adult zebrafish''s visual acuity can be measured, including both binocular and monocular acuities. Because the fish is not harmed during the procedure, the visual acuity can be measured and compared over short or long periods of time. The visual acuity measurements described here can also be done quickly allowing for high throughput and for additional visual procedures if desired. This type of analysis is conducive to drug intervention studies or investigations of disease progression.  相似文献   

2.
目的:用计算机控制检测研究视力时间阈值.方法:用pascal语言程序设计视标.视标的大小、显示程序和持续时间由计算机控制.受试者从距离显示器5m处看视标.采用阶梯法测试不同视力受试者的视力时间阈值.结果:检测到约为毫秒级的视力时间阈值.视力1.0组的视力时间阈值平均约为28.10msec,视力1.2组的视力时间阈值平均约为27.90msec,视力1.5组的视力时间阈值平均约为27.80msec.结论:视力与视力时间阈值不成正比,视力好的个体其视力时间阈值不一定短.  相似文献   

3.
4.
《CMAJ》1954,70(6):687-688
  相似文献   

5.
The frog's visual acuity for gratings was tested with a two-choice prey-dummy setup. The two dummies had a constant position in the visual field, but in one of them a striped pattern was constantly drifting, while the other was a potentially less attention arousing dummy with non-moving stripes. The acuity was tested in bright white light and with different brightness levels of green light (500 nm). The highest acuity 2.8 cycles per degree was achieved with the maximum level of green light. When the brightness was lowered by six orders of magnitude the acuity fell to 0.7 cycles per degree. These behavioural acuities are compared with a theoretically calculated resolving power of the retinal ganglion cell array.  相似文献   

6.
7.
8.
PurposeTo explore the effectiveness of using a series of tests combining near visual acuity (NVA) and distance visual acuity (DVA) for large-scale screenings for significant refractive error (SRE) in primary school children.MethodEach participant underwent DVA, NVA and cycloplegic autorefraction measurements. SREs, including high myopia, high hyperopia and high astigmatism were analyzed. Cycloplegic refraction results were considered to be the gold standard for the comparison of different screening measurements. Receiver-operating characteristic (ROC) curves were constructed to compare the area under the curve (AUC) and the Youden index among DVA, NVA and the series combined tests of DVA and NVA. The efficacies (including sensitivity, specificity, positive predictive value, and negative predictive value) of each test were evaluated. Only the right eye data of each participant were analysed for statistical purpose.ResultA total of 4416 children aged 6 to 12 years completed the study, among which 486 students had right eye SRE (SRE prevalence rate = 11.01%). There was no difference in the prevalence of high hyperopia and high astigmatism among different age groups. However, the prevalence of high myopia significantly increased with the age (χ² = 381.81, p<0.01). High hyperopia was the biggest SRE factor associated with amblyopia(p<0.01,OR = 167.40, 95% CI: 75.14∼372.94). The DVA test was better than the NVA test for detecting high myopia (Z = 2.71, p<0.01), but the NVA test was better for detecting high hyperopia (Z = 2.35, p = 0.02) and high astigmatism (Z = 4.45, p<0.01). The series combined DVA and NVA test had the biggest AUC and the highest Youden Index for detecting high hyperopia, myopia, astigmatism, as well as all of the SREs (all p<0.01).ConclusionThe series combined DVA and NVA test was more accurate for detecting SREs than either of the two tests alone. This new method could be applied to large-scale SRE screening of children, aged 6 to 12, in areas that are less developed.  相似文献   

9.

Purpose

To evaluate visual function in patients with early presbyopia using the functional visual acuity (FVA) test.

Methods

This study included 27 eyes of 27 healthy older volunteers (mean age, 44.1 ± 2.6 years) and 14 eyes of 14 healthy young volunteers (mean age, 28.4±4.8 years). The distance-corrected visual acuity (DCVA), distance-corrected near VA (DCNVA), subjective amplitude of accommodation (AA), and distance and near pupillary diameters were measured. The distance FVA and distance-corrected near FVA (DCNFVA) were measured using the FVA Measurement System. The standard Schirmer test and standard tear break-up time measurement also were performed.

Results

The logarithm of the minimum angle of resolution (logMAR) DCVA was better than 0 in all subjects. The percentages of subjects with logMAR DCNVA below 0 was significantly lower in the presbyopia group than in the young group. The DCNFVA in the presbyopia group was significantly (P < 0.001) poorer than the DCNVA in that group. Significant linear negative correlations were seen between the DCNVA and AA (r = -0.507, P < 0.001) and the DCNFVA and AA (r = -0.681, P < 0.001) in the older subjects. Stepwise regression analysis showed that only the AA was a significant factor predictive of the DCNFVA in the presbyopia group. Tear function parameters were not adopted in the regression model.

Conclusions

Measurement of the DCNFVA can detect decreased AA in early presbyopia better than measurement of the conventional near VA. The DCNFVA is a good index for early presbyopia.  相似文献   

10.
Visual acuity (VA) in 292 schoolchildren aged 8–17 years was measured using Landolt Cs, E letters, and rectangular gratings. With the forced choice procedure, the VA measured with Landolt Cs was 1.4 times higher than with other targets, suggesting analysis of the whole image rather than its gaps by the visual system. In addition, the effect of surrounding images on VA estimates was studied with Landolt Cs, E letters, and gratings surrounded by bars, E letters, and gratings, respectively. A crowding effect, i.e., a worse perception of test objects surrounded by other images, was revealed. However, the perception of Landolt Cs, E letters, and gratings showed age-dependent differences. The separation between the stimulus and surrounding images at which the perception of gratings and other images worsened decreased with age increasing up to 16–17 and 12 years, respectively. The age-related differences were explained by the immaturity of selective-attention mechanisms.  相似文献   

11.
Mobile technology is increasingly used to measure visual acuity. Standards for chart-based acuity tests specify photometric requirements for luminance, optotype contrast and luminance uniformity. Manufacturers provide some photometric data but little is known about tablet performance for visual acuity testing. This study photometrically characterised seven tablet computers (iPad, Apple inc.) and three ETDRS (Early Treatment Diabetic Retinopathy Study) visual acuity charts with room lights on and off, and compared findings with visual acuity measurement standards. Tablet screen luminance and contrast were measured using nine points across a black and white checkerboard test screen at five arbitrary brightness levels. ETDRS optotypes and adjacent white background luminance and contrast were measured. All seven tablets (room lights off) exceeded the most stringent requirement for mean luminance (≥ 120 cd/m2) providing the nominal brightness setting was above 50%. All exceeded contrast requirement (Weber ≥ 90%) regardless of brightness setting, and five were marginally below the required luminance uniformity threshold (Lmin/Lmax ≥ 80%). Re-assessing three tablets with room lights on made little difference to mean luminance or contrast, and improved luminance uniformity to exceed the threshold. The three EDTRS charts (room lights off) had adequate mean luminance (≥ 120 cd/m2) and Weber contrast (≥ 90%), but all three charts failed to meet the luminance uniformity standard (Lmin/Lmax ≥ 80%). Two charts were operating beyond manufacturer’s recommended lamp replacement schedule. With room lights on, chart mean luminance and Weber contrast increased, but two charts still had inadequate luminance uniformity. Tablet computers showed less inter-device variability, higher contrast, and better luminance uniformity than charts in both lights-on and lights-off environments, providing brightness setting was >50%. Overall, iPad tablets matched or marginally out-performed ETDRS charts in terms of photometric compliance with high contrast acuity standards.  相似文献   

12.
13.
The purpose of this study was to obtain age-specific normative data for visual acuity (VA) in sevenyear- old children. The sample included a total of 127 healthy children (mean age 7.53 ± 0.025 years) without ophthalmic disorders. Monocular and binocular VAs were determined to the threshold level at two distances, 5 m and 0.5 m, using eye charts with eight intermediate levels between 1.0 and 2.4 (in the decimal notation system) with widely spaced tumbling Snellen’s E optotypes randomly distributed in four orientations. Since the optotypes were located in lines at intervals that were twice as large as the size of the optotype itself, they could be considered as single stimuli. The normal monocular and binocular VAs were 1.279 ± 0.025 and 1.491 ± 0.028 at 5 m and 1.256 ± 0.024 and 1.388 ± 0.025 m at 0.5 m, respectively (mean ± standard error of mean). Interocular differences in VA are also discussed. Our findings show that the normal VA in seven-yearold children is higher than the clinically accepted norm of 1.0; therefore, VA measurement to the threshold level is necessary for earlier visual disorders to be detected.  相似文献   

14.
Parallel visual search mechanisms have been reported previously only in mammals and birds, and not animals lacking an expanded telencephalon such as bees. Here we report the first evidence for parallel visual search in fish using a choice task where the fish had to find a target amongst an increasing number of distractors. Following two-choice discrimination training, zebrafish were presented with the original stimulus within an increasing array of distractor stimuli. We found that zebrafish exhibit no significant change in accuracy and approach latency as the number of distractors increased, providing evidence of parallel processing. This evidence challenges theories of vertebrate neural architecture and the importance of an expanded telencephalon for the evolution of executive function.  相似文献   

15.

Purpose

To assess the impact of VA loss on patient reported utilities taking both eyes into account compared to taking only the better or the worse eye into account.

Methods

In this cross-sectional study 1085 patients and 254 controls rated preferences with the generic health-related (EQ-5D; n = 868) and vision-specific (Vision and Quality of Life Index (VisQoL); n = 837) multi-attribute utility instruments (MAUIs). Utilities were calculated for three levels of VA in the better and worse eyes, as well as for 6 different vision states based on combinations of the better and worse eye VA.

Results

Using the VisQoL, utility scores decreased significantly with deteriorating vision in both the better and worse eyes when analysed separately. When stratified by the 6 vision states, VisQoL utilities decreased as VA declined in the worse eye despite stable VA in the better eye. Differences in VisQoL scores were statistically significant for cases where the better eye had no vision impairment and the worse seeing fellow eye had mild, moderate or severe vision impairment. In contrast, the EQ-5D failed to capture changes in better or worse eye VA, or any of the six vision states.

Conclusions

Calculating utilities based only on better eye VA or using a generic MAUI is likely to underestimate the impact of vision impairment, particularly when the better eye has no or little VA loss and the worse eye is moderately to severely visually impaired. These findings have considerable implications for the assessment of overall visual impairment as well as economic evaluations within eye health.  相似文献   

16.
17.
The methods used at present for screening young children''s vision have disadvantages, such as that the child''s intelligence can affect the result. In a new method three white cards are used; these are printed with one, two, or three black blocks arranged so that if a child can correctly state the number of blocks at 6 metres the visual acuity is at least 6/9. When tested on 186 children the new method gave better results than conventional tests; eight children with defective vision were picked up only by the new method and none were missed.  相似文献   

18.
外源性视黄酸对斑马鱼心血管系统发育的影响   总被引:2,自引:0,他引:2  
目的观察不同浓度外源性视黄酸对斑马鱼早期胚胎和心血管系统发育的影响,为进一步研究视黄酸影响斑马鱼心脏前后轴(A-P轴)发育的分子机制提供形态学依据。方法选择斑马鱼胚胎孵育的3,6,9·5,12h四个时间点,用不同浓度视黄酸(1×10-6,1×10-7,4×10-8,1×10-8mol/L)处理斑马鱼胚胎,在解剖显微镜下实时观察斑马鱼胚胎心脏发育的全过程和视黄酸对斑马鱼心脏发育的影响。并采用胚胎整体原位杂交技术观察flk-1mRNA在斑马鱼胚胎的表达。结果1×10-6mol/L视黄酸可导致斑马鱼胚胎表现出多系统的严重畸形,胚胎很快死亡。在胚胎孵育的9·5、12h给与10-7~10-8mol/L浓度的视黄酸,胚胎只表现出心血管系统的畸形,其他系统无明显异常。胚胎整体原位杂交显示视黄酸对flk-1mRNA在斑马鱼胚胎血管的表达没有影响。结论视黄酸影响斑马鱼胚胎心脏发育有剂量依赖性和严格的时间窗,视黄酸影响心脏前后轴发育的关键时间是原肠胚晚期。视黄酸处理组胚胎的循环缺陷主要为心脏发育异常所致。10-7~10-8mol/L浓度视黄酸在9·5、12h处理斑马鱼胚胎可以作为研究心脏发育调控机制的动物模型。  相似文献   

19.
Previous psychophysical studies have reported conflicting results concerning the effects of short-term visual deprivation upon tactile acuity. Some studies have found that 45 to 90 minutes of total light deprivation produce significant improvements in participants'' tactile acuity as measured with a grating orientation discrimination task. In contrast, a single 2011 study found no such improvement while attempting to replicate these earlier findings. A primary goal of the current experiment was to resolve this discrepancy in the literature by evaluating the effects of a 90-minute period of total light deprivation upon tactile grating orientation discrimination. We also evaluated the potential effect of short-term deprivation upon haptic 3-D shape discrimination using a set of naturally-shaped solid objects. According to previous research, short-term deprivation enhances performance in a tactile 2-D shape discrimination task – perhaps a similar improvement also occurs for haptic 3-D shape discrimination. The results of the current investigation demonstrate that not only does short-term visual deprivation not enhance tactile acuity, it additionally has no effect upon haptic 3-D shape discrimination. While visual deprivation had no effect in our study, there was a significant effect of experience and learning for the grating orientation task – the participants'' tactile acuity improved over time, independent of whether they had, or had not, experienced visual deprivation.  相似文献   

20.

Purpose

To investigate the relationship between the functional visual acuity (FVA) and useful field of view (UFOV) in elderly drivers and assess the usefulness of the FVA test to screen driving aptitude in elderly drivers.

Methods

This study included 45 elderly drivers (31 men, 14 women; mean age, 68.1 years) and 30 younger drivers (26 men, 4 women; mean age, 34.2 years) who drive regularly. All participants underwent measurement of the binocular corrected distant visual acuity (CDVA), binocular corrected distant FVA (CDFVA), and Visual Field with Inhibitory Tasks Elderly Version (VFIT-EV) to measure UFOV. The tear function and cognitive status also were evaluated.

Results

The CDVA, the CDFVA, cognitive status, and the correct response rate (CAR) of the VFIT-EV were significantly worse in the elderly group than in the control group (P = 0.000 for all parameters). The cognitive status was correlated significantly with the CDVA (r = -0.301, P = 0.009), CDFVA (r = -0.402, P = 0.000), and the CAR of the VFIT-EV (r = 0.348, P = 0.002) in all subjects. The results of the tear function tests were not correlated with the CDVA, CDFVA, or VFIT-EV in any subjects. Stepwise regression analysis for all subjects in the elderly and control groups showed that the CDFVA predicted the CAR most significantly among the clinical factors evaluated.

Conclusion

The FVA test is a promising method to screen the driving aptitude, including both visual and cognitive functions, in a short time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号