首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

The “Timed Up and Go” (TUG) is a widely used measure of physical functioning in older people and in neurological populations, including Parkinson’s Disease. When using an inertial sensor measurement system (instrumented TUG [iTUG]), the individual components of the iTUG and the trunk kinematics can be measured separately, which may provide relevant additional information.

Objective

The aim of this study was to determine intra-rater, inter-rater and test-retest reliability of the iTUG in patients with Parkinson’s Disease.

Methods

Twenty eight PD patients, aged 50 years or older, were included. For the iTUG the DynaPort Hybrid (McRoberts, The Hague, The Netherlands) was worn at the lower back. The device measured acceleration and angular velocity in three directions at a rate of 100 samples/s. Patients performed the iTUG five times on two consecutive days. Repeated measurements by the same rater on the same day were used to calculate intra-rater reliability. Repeated measurements by different raters on the same day were used to calculate intra-rater and inter-rater reliability. Repeated measurements by the same rater on different days were used to calculate test-retest reliability.

Results

Nineteen ICC values (15%) were ≥ 0.9 which is considered as excellent reliability. Sixty four ICC values (49%) were ≥ 0.70 and < 0.90 which is considered as good reliability. Thirty one ICC values (24%) were ≥ 0.50 and < 0.70, indicating moderate reliability. Sixteen ICC values (12%) were ≥ 0.30 and < 0.50 indicating poor reliability. Two ICT values (2%) were < 0.30 indicating very poor reliability.

Conclusions

In conclusion, in patients with Parkinson’s disease the intra-rater, inter-rater, and test-retest reliability of the individual components of the instrumented TUG (iTUG) was excellent to good for total duration and for turning durations, and good to low for the sub durations and for the kinematics of the SiSt and StSi. The results of this fully automated analysis of instrumented TUG movements demonstrate that several reliable TUG parameters can be identified that provide a basis for a more precise, quantitative use of the TUG test, in clinical practice.  相似文献   

2.

Objective

Multiple Sclerosis Spasticity Scale (MSSS)-88 has been developed for self-assessment of spasticity symptoms in patients with multiple sclerosis (MS). The objective of this study was to validate MSSS-88 and evaluate the psychometric properties in patients with MS in Serbia.

Methods

The study comprised 65 MS patients with spasticity. MSSS-88 consists of 88 items grouped in eight sections. Internal consistency of the MSSS-88SR subscales was determined using Cronbach’s alpha coefficient. Test/retest reliability with an intra-class correlation coefficient (ICC) for each MSSS-88SR subscale was performed. Clinical validity of MSSS-88SR was determined by correlations with the Numeric Rating Scale (NRS) and the Modified Ashworth Scale (MAS).

Results

The range of Cronbach’s alpha for all scales and ICC was 0.91–0.96 and 0.84–0.91, respectively. All ICCs were statistically significant (p<0.05). All evaluated subscales of MSSS-88 were significantly correlated with the NRS scale. The highest correlation coefficients were registered between the WL subscale and the EDSS and MAS, while the strongest relationship was observed between the MSS subscale and the NRS.

Conclusion

The Serbian translated version of this instrument may be useful as a clinical measure for spasticity and functionality in patients with MS.  相似文献   

3.

Purpose

To compare the reproducibility of SD-OCT (spectral-domain optical coherence tomography) measurements of RNFL (retinal nerve fiber layer) and macular thickness between children and adults.

Methods

Seventy-one eyes of 71 children and 71 eyes of 71 adults were prospectively enrolled. RNFL and macular thicknesses were measured by one operator, with a brief rest between measurements. The two measurements were obtained using the eye tracking and retest function of Spectralis SD-OCT. Reproducibility was evaluated with reference to COVs (coefficients of variation) and ICCs (intraclass correlation coefficients). The ICC values of the RNFL and macular thicknesses were compared, respectively between the two groups, by Fisher’s z-test.

Results

The RNFL and macular thicknesses did not differ between the two groups. The COVs of the RNFL measurements ranged from 0.945 to 4.531% in the children group and from 0.496 to 1.391% in the adults group. In most of the RNFL sectors, the ICCs of the children group (range: 0.731–0.987) were significantly lower than those of the adults group (range: 0.986–0.993). The COVs of the macular measurements ranged from 0.496 to 1.157% in the children group and from 0.275 to 0.656% in the adults group. The ICCs (range: 0.860–0.974) in the children group, significantly lower than for the adults (range: 0.989–0.995), in all of the macular sectors.

Conclusions

The reproducibility of SD-OCT RNFL and macular measurements for children was excellent, albeit statistically lower than that for adults.  相似文献   

4.

Background

Intrahepatic (ICC) and extrahepatic cholangiocarcinomas (ECC) are tumors that arise from cholangiocytes in the bile duct, but ICCs are coded as primary liver cancers while ECCs are coded as biliary tract cancers. The etiology of these tumors is not well understood. It has been suggested that the etiology of ICC is more similar to that of another type of liver cancer, hepatocellular carcinoma (HCC), than to the etiology of ECC. If this is true, geographic incidence patterns and trends in ICC incidence should be more similar to that of HCC than ECC.

Methods

To examine this hypothesis, data from the North American Association of Central Cancer Registries Cancer in North America data file were analyzed. Incidence rates and joinpoint trends were calculated by demographic subgroup. County-level incidence rates were mapped.

Results

Overall incidence rates, racial distribution, male:female ratio, and peak ages were more similar between ICC and ECC than with HCC. During 2000–2009, average annual incidence rates of ECC increased. During 2005–2009, average annual ICC incidence rates also increased. High rates for all three cancer sites were found in the Pacific region, particularly Hawaii and Alaska. Rates of ICC and ECC were also high in the Northeast and the upper Midwest, while rates of HCC were high in the South.

Conclusions

Demographic patterns and geographical variation were more closely related between ICC and ECC than HCC, suggesting that the etiology of ICC and ECC may be similar. Increasing rates of both tumors suggest that further etiology studies are warranted.  相似文献   

5.

Introduction

There is limited evidence regarding intra-observer and inter-observer variations in echocardiographic measurements of diastolic function. This study aimed to assess this reproducibly within a population-based cohort study.

Methods

Sixty subjects in sinus rhythm were randomly selected among 4th visit participants of the STANISLAS Cohort (Lorraine region, France). This 4th examination systematically included M-mode, 2-dimensional, DTI and pulsed-wave Doppler echocardiograms. Reproducibility of variables was studied by intra-class correlation coefficients (ICC) and Bland Altman plots.

Results

Our population was on average middle-aged (50 ± 14y), overweight (BMI = 26 ± 6kg/m2) and non-smoking (87%) with a quarter of the participants having self-declared hypertension or treated with anti-hypertensive medication(s). Intra-observer ICC were > 0.90 for all analyzed parameters except for left ventricular ejection fraction (LVEF) which was 0.89 (0.81–0.93). The mean relative intra-observer differences were small and limits of agreement of relative differences were narrow for all considered parameters (<5% and <15% respectively). Inter-observer ICC were > 0.90 for all analyzed parameters except for LVEF (ICC = 0.87) and both mitral and pulmonary A wave duration (0.83 and 0.73 respectively). The mean relative inter-observer differences were <5% for all parameters except for pulmonary A wave duration (mean difference = 6.5%). Limits of agreement of relative differences were narrow (<15%), except for mitral A wave duration and velocity (both <20%) as well as left ventricular mass and pulmonary A wave duration (both <30%). Intra-observer agreements with regard to the presence and severity of diastolic dysfunction were excellent (Kappa = 0.93 (0.83–1.00) and 0.88 (0.75–0.99), respectively).

Conclusion

In this validation study within the STANISLAS cohort, diastolic function echocardiographic parameters were found to be highly reproducible. Diastolic dysfunction consequently appears as a highly effective clinical and research tool.  相似文献   

6.

Purpose

To determine the impact of flap creation methods for sub-Bowman’s keratomileusis (SBK) on central Bowman’s layer thickness.

Methods

SBK flaps were made by Moria microkeratome for 20 subjects and by femtosecond (FEMTO) laser for 21 subjects. Corneal sublayer thicknesses were measured by ultra-high resolution optical coherence tomography before SBK and at 1 day, 1 week, 2 weeks, and 1 month afterwards. Each subject was imaged twice on each visit. Thicknesses of central epithelium, Bowman’s layer, flap, and total cornea were calculated using a custom-made automated image processing algorithm. The repeatability of sublayer thickness measurements was tested by the intraclass correlation coefficient (ICC) and by the coefficient of repeatability (CoR) at 1 week post-SBK.

Results

ICCs of the Moria and FEMTO groups were ≥0.959 and ≥0.961 respectively for all sublayer measurements. The segmentation CoRs were less than 6.78% and 5.63% respectively. For both groups, microdistortions were present in the epithelium and Bowman’s layer after SKB. The flap thickness of the Moria group was 9.8 μm (95% confidence interval: 4.8 – 14.8μm) thinner than the FEMTO group one day after SBK (independent samples t-test, P < 0.05). Bowman’s layer became thicker by 1.6 ± 1.1 μm and 1.7 ± 1.6 μm one day post-SBK for the Moria and FEMTO groups (repeated ANOVA, P < 0.05) and then remained stable. Corneal and sublayer thickness were similar between the two groups.

Conclusions

Central Bowman’s layer thickness increased 1 day post-SBK. Flap creation by Moria microkeratome and femtosecond laser did not have significantly different impacts on Bowman’s layer thickness following SBK.

Trial Registration

Chinese Clinical Trial Registry (ChiCTR) NO: ChiCTR-OCH-14004525  相似文献   

7.

Background

The aim of this study is to investigate the expression profile of multiple epithelial mesenchymal transition (EMT)-related molecules in intrahepatic cholangiocarcinoma (ICC) and the related prognostic significance.

Methods

Immunohistochemistry was performed to determine the expression of E-cadherin, Vimentin, Snail, slug and β-catenin in a tissue microarray consisting of tumor tissues of 140 ICC patients undergoing curative resection. The correlation between the expression of these molecules and the clinicopathological characteristics of ICC patients was analyzed, and their prognostic implication was evaluated.

Results

Reduced E-cadherin and increased Vimentin expression, the characteristic changes of EMT, identified in 55.0% and 55.7% of primary ICCs, respectively, were correlated with lymphatic metastasis and poorer overall survival (OS) and disease-free survival (DFS) of ICCs. The overexpression of snail and nonmembranous β-catenin, which are the major regulators of the EMT, were identified in 49.2% and 45.7% of primary ICCs, while little slug expression was detected in ICCs. Cytoplasmic/nuclear β-catenin did not significantly predict worse DFS and was not related with E-cadherin loss. The overexpression of snail predicted worse OS and DFS. Snail overexpression correlated with the down-regulation of E-cadherin and the up-regulation of Vimentin. Inhibition of snail in an ICC cell line decreased the expression of E-cadherin, enhanced the expression of Vimentin and impaired the invasion and migration ability of ICC cells.

Conclusions

These data support the hypothesis that EMT plays vital roles in ICC progression and suggest that snail but not slug and β-catenin plays a crucial role in the EMT induction of ICC.  相似文献   

8.

Background

Inflammation-based prognostic scores such as the neutrophil lymphocyte ratio (NLR), platelet lymphocyte ratio (PLR), Glasgow prognostic score (GPS), and modified GPS (mGPS) have been reported to have prognostic value in patients with many types of cancer, including esophageal squamous cell carcinoma (ESCC). However, the role of the C-reactive protein/Albumin (CRP/Alb) ratio in ESCC has not yet been evaluated.

Methods

A total of 468 patients suffering from histologically proven ESCC were enrolled between January 2000 and July 2010. The GPS, mGPS, NLR, PLR and CRP/Alb ratios were tested together with established prognostic factors in univariate and multivariate Cox regression analyses of overall survival (OS).

Results

The optimal cutoff level for the CRP/Alb ratio was 0.50. The CRP/Alb ratio (continuous) had higher AUC values at 12 months (0.796), 24 months (0.805), and 36 months (0.815) than the NLR, GPS and mGPS. In univariate analysis, the 5-year OS rate for patients with a CRP/Alb ratio > 0.50 was 43.4%, while the rate for patients with a CRP/Alb ratio ≤ 0.50 was 17.7% (P < 0.0001). In multivariate analysis, patients with a CRP/Alb ratio > 0.50 had worse survival than patients with a CRP/Alb ratio ≤ 0.50 (HR: 2.44; 95% CI: 1.82–3.26; P < 0.0001).

Conclusion

In summary, to the best of our knowledge, this is the first study to identify the CRP/Alb ratio as a novel inflammation-based prognostic factor in a large group of ESCC patients. The prognostic value of the CRP/Alb ratio needs to be verified in prospective multicenter studies.  相似文献   

9.

Background

Most studies of microRNA (miRNA) and disease have examined tissue-specific expression in limited numbers of samples. The presence of circulating miRNAs in plasma samples provides the opportunity to examine prospective associations between miRNA expression and disease in initially healthy individuals. However, little data exist on the reproducibility of miRNAs in stored plasma.

Methods

We used Real-Time PCR to measure 61 pre-selected microRNA candidates in stored plasma. Coefficients of variation (CVs) were used to assess inter-assay reliability (n = 15) and within-person stability over one year (n = 80). Intraclass correlation coefficients (ICCs) and polychoric correlation coefficients were used to assess within-person stability and delayed processing reproducibility (whole blood stored at 4°C for 0, 24 and 48 hours; n = 12 samples).

Results

Of 61 selected miRNAs, 23 were detected in at least 50% of samples and had average CVs below 20% for inter-assay reproducibility and 31 for delayed processing reproducibility. Ten miRNAs were detected in at least 50% of samples, had average CVs below 20% and had ICCs above 0.4 for within-person stability over 1–2 years, six of which satisfied criteria for both interassay reproducibility and short-term within-person stability (miR-17-5p, -191-5p, -26a-5p, -27b-3p, -320a, and -375) and two all three types of reproducibility (miR-27b-3p and -26a-5p). However, many miRNAs with acceptable average CVs had high maximum CVs, most had low expression levels, and several had low ICCs with delayed processing.

Conclusions

About a tenth of miRNAs plausibly related to chronic disease were reliably detected in stored samples of healthy adults.  相似文献   

10.

Background

Ki67 labeling index (LI) is used as a predictive marker and is associated with prognosis in breast cancer. However, standardised methodologies for measurement are lacking which has limited its application in clinical practice. In this study, we evaluated the interobserver concordance of visual assessment of Ki67 LI in breast cancer.

Methods

Ki67- immunostained slides of 160 cases of primary invasive breast cancer were visual assessed by five breast pathologists with two different methods to choose the scoring fields: (1) hot-spot score, (2) average score. Proportions of positive invasive tumor cells at 10 % intervals were scored. The intra-class correlation coefficient (ICC) was used to assess the interobserver reproducibility.

Results

(1) A perfect concordance of Ki67 LI was demonstrated according to both score methods (P<0.0001). Average score method (ICC, 0.904) demonstrated a better correlation than hot-spot score method (ICC, 0.894). (2) By respective means according to two score methods, all cases were classified into three groups (≤10%, 11%-30% and >30% Ki-67 LI). The concordance was relatively low in intermediate Ki67 LI group compared with low and high Ki67 LI groups. (3) All cases were classified into three groups by paired-difference (d) between means of hot-spot score and average score (d<5, 5≤d<10, d≥10). The consistency was observed to decrease with increasing paired-difference according to both methods.

Conclusions

Visual assessment of Ki67 LI at 10 % intervals is a candidate for a standard method in breast cancer clinical practice. Average score and hot-spot score of visual assessment both demonstrated a perfect concordance, and an overall average assessment across the whole section including hot spots may be a better method. Interobserver concordance of intermediate Ki67 LI in which most cutoffs are located for making clinical decisions was relatively low.  相似文献   

11.

Purpose

To describe a novel method for quantitative measurement of area parameters in ocular anterior segment ultrasound biomicroscopy (UBM) images using Photoshop software and to assess its intraobserver and interobserver reproducibility.

Methods

Twenty healthy volunteers with wide angles and twenty patients with narrow or closed angles were consecutively recruited. UBM images were obtained and analyzed using Photoshop software by two physicians with different-level training on two occasions. Borders of anterior segment structures including cornea, iris, lens, and zonules in the UBM image were semi-automatically defined by the Magnetic Lasso Tool in the Photoshop software according to the pixel contrast and modified by the observers. Anterior chamber area (ACA), posterior chamber area (PCA), iris cross-section area (ICA) and angle recess area (ARA) were drawn and measured. The intraobserver and interobserver reproducibilities of the anterior segment area parameters and scleral spur location were assessed by limits of agreement, coefficient of variation (CV), and intraclass correlation coefficient (ICC).

Results

All of the parameters were successfully measured by Photoshop. The intraobserver and interobserver reproducibilities of ACA, PCA, and ICA were good, with no more than 5% CV and more than 0.95 ICC, while the CVs of ARA were within 20%. The intraobserver and interobserver reproducibilities for defining the spur location were more than 0.97 ICCs. Although the operating times for both observers were less than 3 minutes per image, there was significant difference in the measuring time between two observers with different levels of training (p<0.001).

Conclusion

Measurements of ocular anterior segment areas on UBM images by Photoshop showed good intraobserver and interobserver reproducibilties. The methodology was easy to adopt and effective in measuring.  相似文献   

12.

Background

To study the morphology of the human spine and new spinal fixation methods, scientists require cadaveric specimens, which are dependent on donation. However, in most countries, the number of people willing to donate their body is low. A 3D printed model could be an alternative method for morphology research, but the accuracy of the morphology of a 3D printed model has not been determined.

Methods

Forty-five computed tomography (CT) scans of cervical, thoracic and lumbar spines were obtained, and 44 parameters of the cervical spine, 120 parameters of the thoracic spine, and 50 parameters of the lumbar spine were measured. The CT scan data in DICOM format were imported into Mimics software v10.01 for 3D reconstruction, and the data were saved in .STL format and imported to Cura software. After a 3D digital model was formed, it was saved in Gcode format and exported to a 3D printer for printing. After the 3D printed models were obtained, the above-referenced parameters were measured again.

Results

Paired t-tests were used to determine the significance, set to P<0.05, of all parameter data from the radiographic images and 3D printed models. Furthermore, 88.6% of all parameters of the cervical spine, 90% of all parameters of the thoracic spine, and 94% of all parameters of the lumbar spine had Intraclass Correlation Coefficient (ICC) values >0.800. The other ICC values were <0.800 and >0.600; none were <0.600.

Conclusion

In this study, we provide a protocol for printing accurate 3D spinal models for surgeons and researchers. The resulting 3D printed model is inexpensive and easily obtained for spinal fixation research.  相似文献   

13.

Purpose

To rebuild the three-dimensional (3-D) model of the anterior segment by high-speed swept-source optical coherence tomography (SSOCT) and evaluate the repeatability of measurement for the parameters of capsule-intraocular lens (C-IOL) complex.

Methods

Twenty-two pseudophakic eyes from 22 patients were enrolled. Three continuous SSOCT measurements were performed in all eyes and the tomograms obtained were used for 3-D reconstruction. The output data were used to evaluate the measurement repeatability. The parameters included postoperative aqueous depth (PAD), the area and diameter of the anterior capsule opening (Area and D), IOL tilt (IOL-T), horizontal, vertical, and space decentration of the IOL, anterior capsule opening, and IOL-anterior capsule opening.

Results

PAD, IOL-T, Area, D, and all decentration measurements showed high repeatability. Repeated measure analysis showed there was no statistically significant difference among the three continuous measurements (all P > .05). Pearson correlation analysis showed high correlation between each pair of them (all r >0.90, P<0.001). ICCs were all more than 0.9 for all parameters. The 95% LoAs of all parameters were narrow for comparison of three measurements, which showed high repeatability for three measurements.

Conclusion

SSOCT is available to be a new method for the 3-D measurement of C-IOL complex after cataract surgery. This method presented high repeatability in measuring the parameters of the C-IOL complex.  相似文献   

14.

Background

The microbial metabolite Trimethylamine-N-oxide (TMAO) has been linked to adverse cardiovascular outcome and mortality in the general population.

Objective

To assess the contribution of TMAO to inflammation and mortality in chronic kidney disease (CKD) patients ranging from mild-moderate to end-stage disease and 1) associations with glomerular filtration rate (GFR) 2) effect of dialysis and renal transplantation (Rtx) 3) association with inflammatory biomarkers and 4) its predictive value for all-cause mortality.

Methods

Levels of metabolites were quantified by a novel liquid chromatography/tandem mass spectrometry-based method in fasting plasma samples from 80 controls and 179 CKD 3–5 patients. Comorbidities, nutritional status, biomarkers of inflammation and GFR were assessed.

Results

GFR was the dominant variable affecting TMAO (β = -0.41; p<0.001), choline (β = -0.38; p<0.001), and betaine (β = 0.45; p<0.001) levels. A longitudinal study of 74 CKD 5 patients starting renal replacement therapy demonstrated that whereas dialysis treatment did not affect TMAO, Rtx reduced levels of TMAO to that of controls (p<0.001). Following Rtx choline and betaine levels continued to increase. In CKD 3–5, TMAO levels were associated with IL-6 (Rho = 0.42; p<0.0001), fibrinogen (Rho = 0.43; p<0.0001) and hsCRP (Rho = 0.17; p = 0.022). Higher TMAO levels were associated with an increased risk for all-cause mortality that remained significant after multivariate adjustment (HR 4.32, 95% CI 1.32–14.2; p = 0.016).

Conclusion

Elevated TMAO levels are strongly associated with degree of renal function in CKD and normalize after renal transplantation. TMAO levels correlates with increased systemic inflammation and is an independent predictor of mortality in CKD 3–5 patients.  相似文献   

15.

Objective

To determine six-year spherical refractive error change among white children and young adults in the UK and evaluate differences in refractive profiles between contemporary Australian children and historical UK data.

Design

Population-based prospective study.

Participants

The Northern Ireland Childhood Errors of Refraction (NICER) study Phase 1 examined 1068 children in two cohorts aged 6–7 years and 12–13 years. Prospective data for six-year follow-up (Phase 3) are available for 212 12–13 year olds and 226 18–20 year olds in each cohort respectively.

Methods

Cycloplegic refractive error was determined using binocular open-field autorefraction (Shin-Nippon NVision-K 5001, cyclopentolate 1%). Participants were defined by spherical equivalent refraction (SER) as myopic SER ≤-0.50D, emmetropic -0.50D<SER<+2.00 or hyperopic SER≥+2.00D.

Main Outcome Measures

Proportion and incidence of myopia.

Results

The proportion of myopes significantly increased between 6–7 years (1.9%) and 12–13 years (14.6%) (p<0.001) but not between 12–13 and 18–20 years (16.4% to 18.6%, p = 0.51). The estimated annual incidence of myopia was 2.2% and 0.7% for the younger and older cohorts respectively. There were significantly more myopic children in the UK at age 12–13 years in the NICER study (16.4%) than reported in Australia (4.4%) (p<0.001). However by 17 years the proportion of myopia neared equivalence in the two populations (NICER 18.6%, Australia 17.7%, p = 0.75). The proportion of myopic children aged 12–13 years in the present study (2006–2008) was 16.4%, significantly greater than that reported for children aged 10–16 years in the 1960’s (7.2%, p = 0.01). The proportion of hyperopes in the younger NICER cohort decreased significantly over the six year period (from 21.7% to 14.2%, p = 0.04). Hyperopes with SER ≥+3.50D in both NICER age cohorts demonstrated persistent hyperopia.

Conclusions

The incidence and proportion of myopia are relatively low in this contemporary white UK population in comparison to other worldwide studies. The proportion of myopes in the UK has more than doubled over the last 50 years in children aged between 10–16 years and children are becoming myopic at a younger age. Differences between the proportion of myopes in the UK and in Australia apparent at 12–13 years were eliminated by 17 years of age.  相似文献   

16.

Objective

To investigate whether the occurrence of nocturnal asymptomatic hypoglycemia may be predicted based on fasting glucose levels and post-breakfast glucose fluctuations.

Patients and Methods

The study subjects comprised type 1 diabetic patients who underwent CGM assessments and received basal-bolus insulin therapy with long-acting insulin. The subjects were evaluated for I) fasting glucose levels and II) the range of post-breakfast glucose elevation (from fasting glucose levels to postprandial 1- and 2-hour glucose levels). The patients were divided into those with asymptomatic hypoglycemia during nighttime and those without for comparison. Optimal cut-off values were also determined for relevant parameters that could predict nighttime hypoglycemia by using ROC analysis.

Results

64 patients (mean HbA1c 8.7 ± 1.8%) were available for analysis. Nocturnal asymptomatic hypoglycemia occurred in 23 patients (35.9%). Fasting glucose levels (I) were significantly lower in those with hypoglycemia than those without (118 ± 35 mg/dL vs. 179 ± 65 mg/dL; P < 0.001). The range of post-breakfast glucose elevation (II) was significantly greater in those with hypoglycemia than in those without (postprandial 1-h, P = 0.003; postprandial 2-h, P = 0.005). The cut-off values determined for relevant factors were as follows: (I) fasting glucose level < 135 mg/dL (sensitivity 0.73/specificity 0.83/AUC 0.79, P < 0.001); and (II) 1-h postprandial elevation > 54 mg/dL (0.65/0.61/0.71, P = 0.006), 2-h postprandial elevation > 78 mg/dL (0.65/0.73/0.71, P = 0.005).

Conclusions

Nocturnal asymptomatic hypoglycemia was associated with increases in post-breakfast glucose levels in type 1 diabetes. Study findings also suggest that fasting glucose levels and the range of post-breakfast glucose elevation could help predict the occurrence of nocturnal asymptomatic hypoglycemia.  相似文献   

17.

Background

Non-ionizing radiation imaging assessment has been advocated for the patients with adolescent idiopathic scoliosis (AIS). As one of the radiation-free methods, ultrasound imaging has gained growing attention in scoliosis assessment over the past decade. The center of laminae (COL) method has been proposed to measure the spinal curvature in the coronal plane of ultrasound image. However, the reliability and validity of this ultrasound method have not been validated in the clinical setting.

Objectives

To evaluate the reliability and validity of clinical ultrasound imaging on lateral curvature measurements of AIS with their corresponding magnetic resonance imaging (MRI) measurements.

Methods

Thirty curves (ranged 10.2°–68.2°) from sixteen patients with AIS were eligible for this study. The ultrasound scan was performed using a 3-D ultrasound unit within the same morning of MRI examination. Two researchers were involved in data collection of these two examinations. The COL method was used to measure the coronal curvature in ultrasound image, compared with the Cobb method in MRI. The intra- and inter-rater reliability of the COL method was evaluated by intra-class correlation coefficient (ICC). The validity of this method was analyzed by paired Student’s t-test, Bland–Altman statistics and Pearson correlation coefficient. The level of significance was set as 0.05.

Results

The COL method showed high intra- and inter-rater reliabilities (both with ICC (2, K) >0.9, p<0.05) to measure the coronal curvature. Compared with Cobb method, COL method showed no significant difference (p<0.05) when measuring coronal curvature. Furthermore, Bland-Altman method demonstrated an agreement between these two methods, and Pearson’s correlation coefficient (r) was high (r>0.9, p<0.05).

Conclusion

The ultrasound imaging could provide a reliable and valid measurement of spinal curvature in the coronal plane using the COL method. Further research is needed to validate the proposed ultrasound measurement in larger clinical trial and to optimize the ultrasound scanning and measuring procedure.  相似文献   

18.
19.

Background

In adults, increased sympathetic and decreased parasympathetic nervous system activity are associated with a less favorable metabolic profile. Whether this is already determined at early age is unknown. Therefore, we aimed to assess the association between autonomic nervous system activation and metabolic profile and its components in children at age of 5–6 years.

Methods

Cross-sectional data from an apparently healthy population (within the ABCD study) were collected at age 5–6 years in 1540 children. Heart rate (HR), respiratory sinus arrhythmia (RSA; parasympathetic activity) and pre-ejection period (PEP; sympathetic activity) were assessed during rest. Metabolic components were waist-height ratio (WHtR), systolic blood pressure (SBP), fasting triglycerides, glucose and HDL-cholesterol. Individual components, as well as a cumulative metabolic score, were analyzed.

Results

In analysis adjusted for child’s physical activity, sleep, anxiety score and other potential confounders, increased HR and decreased RSA were associated with higher WHtR (P< 0.01), higher SBP (p<0.001) and a higher cumulative metabolic score (HR: p < 0.001; RSA: p < 0.01). Lower PEP was only associated with higher SBP (p <0.05). Of all children, 5.6% had 3 or more (out of 5) adverse metabolic components; only higher HR was associated with this risk (per 10 bpm increase: OR = 1.56; p < 0.001).

Conclusions

This study shows that decreased parasympathetic activity is associated with central adiposity and higher SBP, indicative of increased metabolic risk, already at age 5–6 years.  相似文献   

20.

Objective

Health needs of different employee subgroups within an industry can differ. We report the results of a workplace cardiopulmonary risk assessment targeting workers and support staff in the construction industry.

Methods

A free worksite-based cardiopulmonary risk assessment for 1,903 workers on infrastructural contracts across Hong Kong was initiated in May 2014. Cardiopulmonary risk screening was performed in 60-minute blocks for approximately 30 workers/block with individualized feedback and lifestyle counseling. Risk profiles stratified by occupational roles are differentiated using the χ2-test for categorical and Student’s t-test for continuous variables.

Results

Most construction workers and clerks/professionals were male (83.2% and 71.2%, respectively) and Chinese (78.7% and 90.9%, respectively). Construction workers were older (mean: 44.9 years, SD 11.5) and less well-educated (6.1% received tertiary education) than clerks/professionals (35.0 years, 10.7; 72.6% received tertiary education), but more likely to be hypertensive (22.6% vs. 15.4%, p<0.001), overweight/obese (71.7% vs. 56.6%, p<0.001), centrally obese (53.1% vs. 35.5%, p<0.001), and have undesirable levels of high-density lipoprotein (41.6% vs. 35.8%, p<0.05) and diabetic levels of non-fasting blood glucose (4.3% vs. 1.6%, p<0.05). Up to 12.6% of construction workers and 9.7% of office clerks/professions had three or more metabolic syndrome risk factors. While construction workers were more likely than clerks/professionals to be daily smokers, they reported better work-related physical activity and diet.

Conclusions

Simple worksite health risk screening can identify potentially high-cardiopulmonary-risk construction industry employee subgroups for onward confirmatory referral. Separate cardiopulmonary health promotion strategies that account for the varying lifestyle profiles of the two employee subgroups in the industry appear justified.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号