首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The purpose of this investigation was to determine the mechanomyographic (MMG) amplitude and mean power frequency (MPF) versus torque (or force) relationships during isokinetic and isometric muscle actions of the biceps brachii. Ten adults (mean +/- SD age = 21.6 +/- 1.7 years) performed submaximal to maximal isokinetic and isometric muscle actions of the dominant forearm flexors. Following determination of isokinetic peak torque (PT) and the isometric maximum voluntary contraction (MVC), the subjects randomly performed submaximal step muscle actions in 10% increments from 10% to 90% PT and MVC. Polynomial regression analyses indicated that MMG amplitude increased linearly with torque during both the isokinetic (r2 = 0.982) and isometric (r2 = 0.956) muscle actions. From 80% to 100% of isometric MVC, however, MMG amplitude appeared to plateau. Cubic models provided the best fit for the MMG MPF versus isokinetic (R2 = 0.786) and isometric (R2 = 0.940) torque relationships, although no significant increase in MMG MPF was found from 10% to 100% of isokinetic PT. For the isometric muscle actions, however, MMG MPF remained relatively stable from 10% to 50% MVC, increased from 50% to 80% MVC, and decreased from 80% to 100% MVC. The results demonstrated differences in the MMG amplitude and MPF versus torque relationships between the isokinetic and isometric muscle actions. These findings suggested that the time and frequency domains of the MMG signal may be useful for describing the unique motor control strategies that modulate dynamic versus isometric torque production.  相似文献   

2.
The purpose of this investigation was to determine the effect of hyperhydration on the electromyographic (EMG) and mechanomyographic (MMG) responses during isometric and isokinetic muscle actions of the biceps brachii. Eight (22.1 +/- 1.8 years, 79.5 +/- 22.8 kg) subjects were tested for maximal isometric, submaximal isometric, and maximal concentric isokinetic muscle strength in either a control (C) or hyperhydrated (H) state induced by glycerol ingestion while the EMG and MMG signals were recorded. Although fluid retention was significantly greater during the H protocol, the analyses indicated no change in torque, EMG amplitude, EMG mean power frequency (MPF), MMG amplitude, or MMG MPF with hyperhydration. These results indicated that glycerol-induced fluid retention does not affect the torque-producing capabilities of a muscle, the impulses (EMG) going to a muscle, or muscular vibrations (MMG). It has been suggested that EMG and MMG can be used as direct electrical/mechanical monitoring, which could be presented to trainers and athletes; however, before determining the utility of these signals, the MMG and EMG responses should be examined under a variety of conditions such as in the present study.  相似文献   

3.
The purpose of this study was to examine the patterns for the mechanomyographic (MMG) and electromyographic (EMG) amplitude and mean power frequency (MPF) vs. torque relationships during submaximal to maximal isometric and isokinetic muscle actions. Seven men (mean +/- SD age, 22.4 +/- 1.3 years) volunteered to perform isometric and concentric isokinetic leg extension muscle actions at 20, 40, 60, 80, and 100% of maximal voluntary contraction (MVC) and peak torque (PT) on a Cybex II dynamometer. A piezoelectric MMG recording sensor was placed between bipolar surface EMG electrodes on the vastus medialis. Polynomial regression and separate 1-way repeated-measures analysis of variance were used to analyze the EMG amplitude, MMG amplitude, EMG MPF, and MMG MPF data for the isometric and isokinetic muscle actions. For the isometric muscle actions, EMG amplitude (R(2) = 0.999) and MMG MPF (R(2) = 0.946) increased to MVC, mean MMG amplitude increased to 60% MVC and then plateaued, and mean EMG MPF did not change (p > 0.05) across torque levels. For the isokinetic muscle actions, EMG amplitude (R(2) = 0.988) and MMG amplitude (R(2) = 0.933) increased to PT, but there were no significant mean changes with torque for EMG MPF or MMG MPF. The different torque-related responses for EMG and MMG amplitude and MPF may reflect differences in the motor control strategies that modulate torque production for isometric vs. dynamic muscle actions. These results support the findings of others and suggest that isometric torque production was modulated by a combination of recruitment and firing rate, whereas dynamic torque production was modulated primarily through recruitment.  相似文献   

4.
The purpose of this review is to examine the literature that has investigated the potential relationship between mechanomyographic (MMG) frequency and motor unit firing rates. Several different experimental designs/methodologies have been used to address this issue, including: repetitive electrical stimulation, voluntary muscle actions in muscles with different fiber type compositions, fatiguing and non-fatiguing isometric or dynamic muscle actions, and voluntary muscle actions in young versus elderly subjects and healthy individuals versus subjects with a neuromuscular disease(s). Generally speaking, the results from these investigations have suggested that MMG frequency is related to the rate of motor unit activation and the contractile properties (contraction and relaxation times) of the muscle fibers. Other studies, however, have reported that MMG mean power frequency (MPF) does not always follow the expected pattern of firing rate modulation (e.g. motor unit firing rates generally increase with torque during isometric muscle actions, but MMG MPF may remain stable or even decrease). In addition, there are several factors that may affect the frequency content of the MMG signal during a voluntary muscle action (i.e. muscle stiffness, intramuscular fluid pressure, etc.), independent of changes in motor unit firing rates. Despite the potential influences of these factors, most of the evidence has suggested that the frequency domain of the MMG signal contains some information regarding motor unit firing rates. It is likely, however, that this information is qualitative, rather than quantitative in nature, and reflects the global motor unit firing rate, rather than the firing rates of a particular group of motor units.  相似文献   

5.
The purpose of this study was to compare a piezoelectric contact sensor with an accelerometer for measuring the mechanomyographic (MMG) signal from the biceps brachii during submaximal to maximal isokinetic and isometric forearm flexion muscle actions. Following determination of isokinetic peak torque (PT) and the isometric maximum voluntary contraction (MVC), 10 adults (mean+/-SD age=22.8+/-2.7yrs) performed randomly ordered, submaximal step muscle actions of the dominant forearm flexors in 20% increments from 20% to 80% PT and MVC. Surface MMG signals were recorded simultaneously from a contact sensor and an accelerometer placed over the belly of the biceps brachii muscle. During the isokinetic and isometric muscle actions, the contact sensor and accelerometer resulted in linear increases in normalized MMG amplitude with torque (r(2) range=0.84-0.97) but the linear slope of the normalized MMG amplitude versus isokinetic torque relationship for the accelerometer was less (p<0.10) than that of the contact sensor. There was no significant (p>0.05) relationship for normalized MMG mean power frequency (MPF, %max) versus isokinetic and isometric torque for the contact sensor, but the accelerometer demonstrated a quadratic (R(2)=0.94) or linear (r(2)=0.83) relationship for the isokinetic and isometric muscle actions, respectively. There were also a number of significant (p<0.05) mean differences between the contact sensor and accelerometer for normalized MMG amplitude or MPF values. These findings indicated that in some cases involving dynamic and isometric muscle actions, the contact sensor and accelerometer resulted in different torque-related responses that may affect the interpretation of the motor control strategies involved.  相似文献   

6.
This study compared the patterns of mechanomyographic (MMG) amplitude and mean power frequency vs. torque relationships in men and women during isometric muscle actions of the biceps brachii. Seven men (mean age 23.9 +/- 3.5 yrs) and 8 women (mean 21.0 +/- 1.3 yrs) performed submaximal to maximal isometric muscle actions of the dominant forearm flexors. Following determination of the isometric maximum voluntary contraction (MVC), they randomly performed submaximal step muscle actions in 10% increments from 10% to 90% MVC. Polynomial regression analyses indicated that the MMG amplitude vs. isometric torque relationship for the men was best fit with a cubic model (R(2) = 0.983),,where MMG amplitude increased slightly from 10% to 20% MVC, increased rapidly from 20% to 80% MVC, and plateaued from 80% to 100% MVC. For the women, MMG amplitude increased linearly (r(2) = 0.949) from 10% to 100% MVC. Linear models also provided the best fit for the MMG mean power frequency vs. isometric torque relationship in both the men (r(2) = 0.813) and women (r(2) = 0.578). The results demonstrated gender differences in the MMG amplitude vs. isometric torque relationship, but similar torque-related patterns for MMG mean power frequency. These findings suggested that the plateau in MMG amplitude at high levels of isometric torque production for the biceps brachii in the men, but not the women, may have been due to greater isometric torque, muscle stiffness, and/or intramuscular fluid pressure in the men, rather than to differences in motor unit activation strategies for modulating isometric torque production.  相似文献   

7.
In comparison to isometric muscle action models, little is known about the electromyographic (EMG) and mechanomyographic (MMG) amplitude and mean power frequency (MPF) responses to fatiguing dynamic muscle actions. Simultaneous examination of the EMG and MMG amplitude and MPF may provide additional insight with regard to the motor control strategies utilized by the superficial muscles of the quadriceps femoris during a concentric fatiguing task. Thus, the purpose of this study was to examine the EMG and MMG amplitude and MPF responses of the vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM) during repeated, concentric muscle actions of the dominant leg. Seventeen adults (21.8+/-1.7 yr) performed 50 consecutive, maximal concentric muscle actions of the dominant leg extensors on a Biodex System 3 Dynamometer at velocities of 60 degrees s(-1) and 300 degrees s(-1). Bipolar surface electrode arrangements were placed over the mid portion of the VL, RF, and VM muscles with a MMG contact sensor placed adjacent to the superior EMG electrode on each muscle. Torque, MMG and EMG amplitude and MPF values were calculated for each of the 50 repetitions. All values were normalized to the value recorded during the first repetition and then averaged across all subjects. The cubic decreases in torque at 60 degrees s(-1) (R2 = 0.972) and 300 degrees s(-1) (R2 = 0.931) was associated with a decline in torque of 59+/-24% and 53+/-11%, respectively. The muscle and velocity specific responses for the MMG amplitude and MPF demonstrated that each of the superficial muscles of the quadriceps femoris uniquely contributed to the control of force output across the 50 repetitions. These results suggested that the MMG responses for the VL, RF, VM during a fatiguing task may be influenced by a number of factors such as fiber type differences, alterations in activation strategy including motor unit recruitment and firing rate and possibly muscle wisdom.  相似文献   

8.
The purposes of this study were to examine the mechanomyographic (MMG) and electromyographic (EMG) time and frequency domain responses of the vastus lateralis (VL) and rectus femoris (RF) muscles during isometric ramp contractions and compare the time-frequency of the MMG and EMG signals generated by the short-time Fourier transform (STFT) and continuous wavelet transform (CWT). Nineteen healthy subjects (mean+/-SD age=24+/-4 years) performed two isometric maximal voluntary contractions (MVCs) before and after completing 2-3, 6-s isometric ramp contractions from 5% to 100% MVC with the right leg extensors. MMG and surface EMG signals were recorded from the VL and RF muscles. Time domains were represented as root mean squared amplitude values, and time-frequency representations were generated using the STFT and CWT. Polynomial regression analyses indicated cubic increases in MMG amplitude, MMG frequency, and EMG frequency, whereas EMG amplitude increased quadratically. From 5% to 24-28% MVC, MMG amplitude remained stable while MMG frequency increased. From 24-28% to 76-78% MVC, MMG amplitude increased rapidly while MMG frequency plateaued. From 76-78% to 100% MVC, MMG amplitude plateaued (VL) or decreased (RF) while MMG frequency increased. EMG amplitude increased while EMG frequency changed only marginally across the force spectrum with no clear deflection points. Overall, these findings suggested that MMG may offer more unique information regarding the interactions between motor unit recruitment and firing rate that control muscle force production during ramp contractions than traditional surface EMG. In addition, although the STFT frequency patterns were more pronounced than the CWT, both algorithms produced similar time-frequency representations for tracking changes in MMG or EMG frequency.  相似文献   

9.
The purpose of this study was to examine the strength, electromyographic (EMG), and mechanomyographic (MMG) responses after workouts designed to elicit fatigue and muscle damage vs. only fatigue. Thirteen men (mean ± SD age = 23.7 ± 2.2 years) performed 6 sets of 10 maximal concentric isokinetic (CONexercise) or eccentric isokinetic (ECCexercise) muscle actions of the dominant forearm flexors on 2 separate days. Before (PRE) and after (POST) these workouts, peak torque (PT), surface EMG, and MMG signals were measured during maximal concentric isokinetic, eccentric isokinetic, and isometric muscle actions of the forearm flexors. The subjects also visited the laboratory for a control (CTL) visit with quiet resting between the PRE and POST measurements, rather than performing the CONexercise or ECCexercise. The results showed that there were significant 26 and 25% decreases in PT after the CONexercise and ECCexercise, respectively, and these decreases were statistically equivalent for the concentric, eccentric, and isometric muscle actions. There were also 19 and 23% reductions in normalized EMG amplitude after the CONexercise and ECCexercise, respectively, but no changes in EMG mean frequency (MNF), MMG amplitude, or MMG MNF. These findings demonstrated a neural component(s) to the strength decrement after CONexercise and ECCexercise. It is possible that after these 2 types of exercise, activation of free nerve endings that are sensitive to muscle damage and pH changes resulted in inhibition of alpha motor neurons, causing decreased muscle activation and torque. These findings suggest that training programs designed to minimize strength loss during competition should consider the fact that at least some of this loss is because of neural factors.  相似文献   

10.
Eighteen adults performed isometric muscle actions of the leg extensors at 25, 50, 75, and 100% maximal voluntary contraction (%MVC) at leg flexion angles of 25, 50, and 75 degrees. The results indicated that isometric torque production increased as leg flexion angle increased (75 degrees > 50 degrees > 25 degrees). For each muscle tested (rectus femoris, vastus lateralis, and vastus medialis), the EMG amplitude increased up to 100%MVC at each leg flexion angle (25, 50, and 75 degrees). The MMG amplitude for each muscle, however, increased up to 100%MVC at 25 and 50 degrees of leg flexion, but plateaued from 75 to 100%MVC at 75 degrees of leg flexion. We hypothesize that the varied patterns for the MMG amplitude-isometric torque relationships were due to leg flexion angle differences in: (1) muscle stiffness, (2) intramuscular fluid pressure, or (3) motor unit firing frequency.  相似文献   

11.
The purpose of this study was to investigate changes in mechanomyographic (MMG) intensity patterns for the vastus lateralis (VL), rectus femoris (RF) and vastus medialis (VM) during submaximal to maximal concentric isokinetic, eccentric isokinetic and isometric muscle actions of the leg extensors. Eleven men (mean ± SD age = 20.1 ± 1.1 years) performed concentric, eccentric and isometric muscle actions of the dominant leg extensors on 3 separate days. Surface MMG signals were detected from the VL, RF and VM, processed with a wavelet analysis and examined with a trend plot. The results indicated that the trend plot was capable of tracking systematic changes in MMG amplitude and frequency with an increase in torque. However, these changes were statistically significant in only 26% of the cases. There were also no consistent differences between muscles or contraction types for the significance of the trend plots.  相似文献   

12.
The purpose of this investigation was to examine the effect of leg flexion angle on the relationship between mechanomyographic (MMG) amplitude and isometric torque production. Adult males (n = 9) performed isometric muscle actions of the leg extensors at 25, 50, 75, and 100 percent maximal voluntary contraction (%MVC) on a calibrated CYBEX 6000 dynamometer at 25, 50, and 75° below full extension. A piezoelectric MMG recording device was placed over the mid-portion of the rectus femoris. At 25° of leg flexion, the MMG amplitude increased to 100%MVC. At 50 and 75° of leg flexion, however, MMG amplitude increased to 75%MVC, and then did not change significantly (P > 0.05) between 75 and 100%MVC. These findings indicate that the MMG amplitude-isometric torque relationship is joint angle specific and may be the result of leg flexion angle differences in: (1) muscle stiffness, or (2) motor unit activation strategies. Accepted: 2 March 1998  相似文献   

13.
The purpose of this study was to investigate the influence of changes in ankle joint angle on the mechanomyogram (MMG) amplitude of the human medial gastrocnemius (MG) muscle during voluntary isometric plantarflexion contractions. Ten healthy individuals were asked to perform voluntary isometric contractions at six different contraction intensities (from 10% to 100%) and at three different ankle joint angles (plantarflexion of 26°; plantarflexion of 10°; dorsiflexion of 3°). MMG signals were recorded from the surface over the MG muscle, using a 3-axis accelerometer. The relations between root mean square (RMS) MMG and isometric plantarflexion torque at different ankle joint angles were characterized to evaluate the effects of altered muscle mechanical properties on RMS MMG.We found that the relation between RMS MMG and plantarflexion torque is changed at different ankle joint angles: RMS MMG increases monotonically with increasing the plantarflexion torque but decreases as the ankle joint became dorsiflexed. Moreover, RMS MMG shows a negative correlation with muscle length, with passive torque, and with maximum voluntary torque, which were all changed significantly at different ankle joint angles.Our findings demonstrate the potential effects of changing muscle mechanical properties on muscle vibration amplitude. Future studies are required to explore the major sources of this muscle vibration from the perspective of muscle mechanics and muscle activation level, attributable to changes in the neural command.  相似文献   

14.
The purpose of this study was to examine the responses of peak torque (PT), mean power output (MP), mechanomyographic (MMG) and electromyographic (EMG) amplitudes, and mean power frequencies (MPFs) of the vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM) in men and women during dynamic muscle actions. Twelve women (mean +/- SD age = 22 +/- 3 years) and 11 men (22 +/- 3 years) performed maximal, concentric, isokinetic leg extensions at velocities of 60, 120, 180, 240, and 300 degrees x s(-1) on a Cybex 6000 dynamometer. Piezoelectric MMG-recording sensors and bipolar surface EMG electrodes were placed over the VL, RF, and VM muscles. No sex-related differences were found among the velocity-related patterns for PT, MP, MMG amplitude, MMG MPF, or EMG MPF. There were, however, sex-related differences in the patterns of EMG amplitude across velocity. The results indicated similar velocity-related patterns of increase of MP and MMG amplitude for all 3 muscles and of EMG amplitude for the VL and VM in the women. Velocity-related decreases (p 0.05) across velocity. MMG MPF increased (p < or = 0.05) only between 240 and 300 degrees x s(-1). Overall, these findings suggested that there were sex- and muscle-specific, velocity-related differences in the associations among motor unit activation strategies (EMG amplitude and MPF) and the mechanical aspects of muscular activity (MMG amplitude and MPF). With additional examination and validation, however, MMG may prove useful to practitioners for monitoring training-induced changes in muscle power output.  相似文献   

15.
Motor unit activation patterns were studied during four different force levels of concentric and eccentric actions. Eight male subjects performed concentric and eccentric forearm flexions with the movement range from 100 degrees to 60 degrees in concentric and from 100 degrees to 140 degrees elbow angle in eccentric actions. The movements were started either from zero preactivation or with isometric preactivation of the force levels of 20, 40, 60 and 80% MVC. The subjects were then instructed to maintain the corresponding relative force levels during the dynamic actions. Intramuscular and surface EMG was recorded from biceps brachii muscle. Altogether 28 motoneuron pools were analyzed using the intramuscular spike-amplitude frequency (ISAF) analysis technique of Moritani et al. The mean spike amplitude was lower and the mean spike frequency higher in the isometric preactivation phase than in the consequent concentric and eccentric actions. When the movements started with isometric preactivation the mean spike amplitude increased significantly (P<0.001) up to 80% in isometric and concentric actions but in eccentric actions the increase continued only up to 60% (P<0.01). The mean spike frequency in isometric preactivation and in concentric action with preactivation was lower only at the 20% force level (P<0.01) as compared to the other force levels while in eccentric action with preactivation the increase between the force levels was significant (P<0.01) up to 60%. When the movement was started without preactivation the mean spike amplitude at 20% and at 40% force level was higher (P<0.01) in eccentric action than in concentric actions. It was concluded that the recruitment threshold may be lower in dynamic as compared to isometric actions. The recruitment of fast motor units may continue to higher force levels in isometric and in concentric as in eccentric actions which, on the other hand, seems to achieve the higher forces by increasing the firing rate of the active units. At the lower force levels mean spike amplitude was higher in eccentric than in concentric actions which might indicate selective activation of fast motor units. This was, however, the case only when the movements were started without isometric preactivation.  相似文献   

16.
The purpose of this investigation was to examine mechanomyographic (MMG) and electromyographic (EMG) amplitude responses of the superficial quadriceps femoris muscles during the Wingate Anaerobic Test (WAnT). Ten healthy adults (age 21 +/- 1.2 years) volunteered to perform the WAnT on a calibrated Monark 894E cycle ergometer while the EMG and MMG signals were recorded. The EMG and MMG amplitude and power output (W) values per 5-second segments of the test were averaged and normalized to the highest value found during the test, respectively. The statistical analysis indicated that EMG amplitude did not change significantly over the 30-second test, but W and MMG amplitude decreased significantly. There is dissociation between EMG and MMG amplitude over the 30-second anaerobic test, providing evidence that MMG amplitude could be used as a monitor of W during such a task. MMG amplitude could potentially be used as a direct monitor of mechanical activity, which could be of benefit to those who train athletes when a direct assessment of mechanical contribution from a given muscle to a fatiguing activity is desired (such as when monitoring an injury), but it must be studied under various conditions, such as the current study, before such applications are made.  相似文献   

17.
The purpose of this pilot study was to determine the influence of oral contraceptives (OC) on electromyography (EMG) and mechanomyography (MMG) during isometric (ISO) muscle actions of the rectus femoris. Two groups of women (Mean +/- SEM, 24 +/- 1 yrs, 1.68 +/- 0.02 m, 70.97 +/- 4.81 kg) were recruited and tested five times throughout one complete menstrual cycle. The first group (n=7) were not taking hormonal treatment (NOC) and the OC group (n=6) had been taking exogenous hormones for at least six months prior. Each participant performed maximal ISO muscle actions (MVC) of the leg extensors on a Cybex II isokinetic dynamometer followed by randomly assigned sub-maximal ISO muscle actions. Bipolar surface EMG electrodes were placed over the rectus femoris with a piezoelectric MMG recording device placed between the two electrodes. Three separate three way (group x day x %MVC) mixed factorial repeated measures ANOVAs were used to determine differences in torque, EMG and MMG between NOC and OC subjects. There were no significant three-way interactions involving group for normalized torque, EMG or MMG. These results indicated that OC does not have an effect on torque, EMG or MMG during ISO muscle actions of the rectus femoris.  相似文献   

18.
The purpose of this study was to examine the acute effects of static versus dynamic stretching on peak torque (PT) and electromyographic (EMG), and mechanomyographic (MMG) amplitude of the biceps femoris muscle (BF) during isometric maximal voluntary contractions of the leg flexors at four different knee joint angles. Fourteen men ((mean +/- SD) age, 25 +/- 4 years) performed two isometric leg flexion maximal voluntary contractions at knee joint angles of 41 degrees , 61 degrees , 81 degrees , and 101 degrees below full leg extension. EMG (muV) and MMG (m x s(-2)) signals were recorded from the BF muscle while PT values (Nm) were sampled from an isokinetic dynamometer. The right hamstrings were stretched with either static (stretching time, 9.2 +/- 0.4 minutes) or dynamic (9.1 +/- 0.3 minutes) stretching exercises. Four repetitions of three static stretching exercises were held for 30 seconds each, whereas four sets of three dynamic stretching exercises were performed (12-15 repetitions) with each set lasting 30 seconds. PT decreased after the static stretching at 81 degrees (p = 0.019) and 101 degrees (p = 0.001) but not at other angles. PT did not change (p > 0.05) after the dynamic stretching. EMG amplitude remained unchanged after the static stretching (p > 0.05) but increased after the dynamic stretching at 101 degrees (p < 0.001) and 81 degrees (p < 0.001). MMG amplitude increased in response to the static stretching at 101 degrees (p = 0.003), whereas the dynamic stretching increased MMG amplitude at all joint angles (p 相似文献   

19.
The purpose of this study was to determine if an active warm-up affects peak torque (PT), rate of torque development (RTD), and the electromyographic (EMG) and mechanomyographic (MMG) signals. Twenty-one men (mean age ± SD: 24.0 ± 2.7 years) visited the exercise physiology laboratory on 2 occasions. During the first visit, they either performed an active warm-up (10 minutes of stationary cycling at 70% of predicted maximum heart rate) or sat quietly (no warm-up). Participants were then tested for isometric and isokinetic (60°, 180°, and 300°·s) PT, and RTD (measured as S-gradient) on an isokinetic dynamometer. Electromyographic and MMG sensors were placed over the vastus lateralis muscle to monitor the electrical and mechanical aspects of muscle contractions, respectively. The testing protocol used for the first visit was repeated for the second visit, but the preexercise treatment (warm-up, no warm-up) not given during the first visit was administered. The results indicated that an active warm-up did not affect PT, RTD, or measures of muscle activation as reflected by EMG amplitude, EMG frequency, or MMG frequency (p > 0.05). However, MMG amplitude at 180°·s was significantly greater in the warm-up condition compared with the no warm-up condition. The isolated increase in MMG amplitude suggested that warm-up may have affected the mechanical properties of muscle by reducing muscular stiffness or decreasing intramuscular fluid pressure, but that it was not sufficient to influence performance.  相似文献   

20.
The mechanomyographic (MMG) signal analysis has been performed during single motor unit (MU) contractions of the rat medial gastrocnemius muscle. The MMG has been recorded as a muscle surface displacement by using a laser distance sensor. The profiles of the MMG signal let to categorize these signals for particular MUs into three classes. Class MMG-P (positive) comprises MUs with the MMG signal similar to the force signal profile, where the distance between the muscle surface and the laser sensor increases with the force increase. The class MMG-N (negative) has also the MMG profile similar to the force profile, however the MMG is inverted in comparison to the force signal and the distance measured by using laser sensor decreases with the force increase. The third class MMG-M (mixed) characterize the MMG which initially increases with the force increases and when the force exceeds some level it starts to decrease towards the negative values. The semi-pennate muscle model has been proposed, enabling estimation of the MMG generated by a single MU depending on its localization. The analysis have shown that in the semi-pennate muscle the localization of the MU and the relative position of the laser distance sensor determine the MMG profile and amplitude. Thus, proposed classification of the MMG recordings is not related to the physiological types of MUs, but only to the MU localization and mentioned sensor position. When the distance sensor is located over the middle of the muscle belly, a part of the muscle fibers have endings near the location of the sensor beam. For the MU MMG of class MMG-N the deflection of the muscle surface proximal to the sensor mainly influences the MMG recording, whereas for the MU MMG class MMG-P, it is mainly the distal muscle surface deformation. For the MU MMG of MMG-M type the effects of deformation within the proximal and distal muscle surfaces overlap. The model has been verified with experimental recordings, and its responses are consistent and adequate in comparison to the experimental data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号