相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In-vitro biomechanical testing is widely performed for characterizing the load-displacement characteristics of intact, injured, degenerated, and surgically repaired osteoligamentous spine specimens. Traditional specimen fixture devices offer an unspecified rigidity of fixation, while varying in the associated amounts and reversibility of damage to and “coverage” of a specimen – factors that can limit surgical access to structures of interest during testing as well as preclude the possibility of testing certain segments of a specimen. Therefore, the objective of this study was to develop a specimen fixture system for spine biomechanical testing that uses components of clinically available spinal fixation hardware and determine whether the new system provides sufficient rigidity for spine biomechanical testing. Custom testing blocks were mounted into a robotic testing system and the angular deflection of the upper fixture was measured indirectly using linear variable differential transformers. The fixture system had an overall stiffness 37.0, 16.7 and 13.3 times greater than a typical human functional spine unit for the flexion/extension, axial rotation and lateral bending directions respectively – sufficient rigidity for biomechanical testing. Fixture motion when mounted to a lumbar spine specimen revealed average motion of 0.6, 0.6, and 1.5° in each direction. This specimen fixture method causes only minimal damage to a specimen, permits testing of all levels of a specimen, and provides for surgical access during testing.  相似文献   

2.
Flexure is a major deformation mode of the aortic valve (AV) leaflet, particularly in the commissural region where the upper portion of the leaflet joins the aortic root. However, there are no existing data known on the mechanical properties of leaflet in the commissural region. To address this issue, we quantified the effective stiffness of the commissural region using a cantilever beam method. Ten specimens were prepared, with each specimen flexed in the direction of natural leaflet motion (forward) and against the natural motion (reverse). At a flexure angle (phi) of 30 degrees , the effective forward direction modulus E was 42.63+/-4.44 kPa and the reverse direction E was 75.01+/-14.53 kPa (p=0.049). Further, E-phi response was linear (r(2) approximately 0.9) in both flexural directions. Values for dE/dphi were -2.24+/-0.6 kPa/ degrees and -1.90+/-0.3 kPa/ degrees in the forward and reverse directions, respectively (not statistically different, p=0.424), indicating a consistent decrease in stiffness with increased flexure. In comparison, we have reported that the effective tissue stiffness of AV leaflet belly region was 150-200 kPa [Merryman, W.D., Huang, H.Y.S., Schoen, F.J., Sacks, M.S. (2006). The effects of cellular contraction on AV leaflet flexural stiffness. Journal of Biomechanics 39 (1), 88-96], which was also independent of direction and amount of flexure. Histological studies of the commissure region indicated that tissue buckling was a probable mechanism for decrease in E with increasing flexure. The observed change in E with flexural angle in the commissural region is a subtle aspect of valve function. From a valve design perspective, these findings can be used as design criteria in fabricating prosthetic devices AV resulting in better functional performance.  相似文献   

3.
Apparatus-induced artifacts may invalidate standard spine testing protocols. Kinematic measurements may be compromised by the configuration of motion capture equipment. This study has determined: (1) the influence of machine design (component friction) on in vitro spinal kinetics; (2) the sensitivity of kinematic measurements to variations in the placement of motion capture markers. A spinal loading simulator has been developed to dynamically apply pure bending moments (three axes) with or without a simultaneous compressive preload. Two linear slider types with different friction coefficients, one with caged ball bearings and one with high-precision roller bearings on rails, were mounted and specimen response compared in sequential tests. Three different optoelectronic marker cluster configurations were mounted on the specimen and motion data was captured simultaneously from all clusters during testing. A polymer tube with a uniform bending stiffness approximately equivalent to a polysegmental lumbar spine specimen was selected to allow reproducible behavior over multiple tests. The selection of sliders for linear degrees of freedom had a marked influence on parasitic shear forces. Higher shear forces were recorded with the caged-bearing design than with the high-precision rollers and consequently a higher moment was required to achieve a given rotation. Kinematic accuracy varied with each marker configuration, but in general higher accuracy was achieved with larger marker spacings and situations where markers moved predominantly parallel to the camera's imaging plane. Relatively common alternatives in the mechanical components used in an apparatus for in vitro spine testing can have a significant influence on the measured kinematic and kinetics. Low-magnitude parasitic shear forces due to friction in sliders induces a linearly increasing moment along the length of the specimen, precluding the ideal of pure moment application. This effect is compounded in polysegmental specimens. Kinematic measurements are highly sensitive to marker design and placement, despite equivalent absolute precision of individual marker measurements, however marker configurations can be designed to minimize errors related to spatial distribution and system bias.  相似文献   

4.
This study determined the test-retest reliability of Patrick's test as a hip range of motion assessment method. Fifty healthy college-aged men (mean age = 20.0 years) were studied during 2 testing sessions separated by 24 hours. A single inexperienced tester performed all the measurements in this study. Before data collection, the tester participated in a 15-minute instructional session on how to perform Patrick's test. To determine the range of motion associated with Patrick's test, the tester passively flexed, abducted, and externally rotated the hip of the lower extremity that was to be tested while subjects were in a supine position, so that the lateral malleolus of the tested lower extremity rested just superior to their opposite extended knee. The vertical distance between a mark on the lateral border of the patella of the tested lower extremity and the treatment table was then measured. The results revealed that Patrick's test demonstrated high test-retest reliability (intraclass correlation coefficient = 0.93). The results of this study support the use of Patrick's test as being a reliable measure of general hip motion when used by an inexperienced tester who participated in a 15-minute instructional session on how to perform Patrick's test.  相似文献   

5.
This paper presents a novel application of a velocity-based force control routine used for robotic biomechanical testing. The routine employs a jog function, available from the robot's motion commands, that permits easy adjustment of velocity on each axis. Force and moment targets are achieved by adjusting jog velocities in proportion to force or moment errors while limiting the maximum velocity of the system. The force control jog routine does not require specimen stiffness values and is inherently stable. The performance of the method was shown to be suitable for unconstrained in vitro spine testing in a rabbit model where extremely small motions are necessary to maintain the target force values. The jogging feature on which this work is based is a feature available on most robots and is equally applicable to a serial robot. The simplicity, stability, and performance of this method warrant its consideration for other robotic biomechanical testing applications where force control is required.  相似文献   

6.
The objective of this study was to implement a follower load (FL) device within a robotic (universal force-moment sensor) testing system and utilize the system to explore the effect of FL on multi-segment cervical spine moment-rotation parameters and intradiscal pressure (IDP) at C45 and C56. Twelve fresh-frozen human cervical specimens (C3-C7) were biomechanically tested in a robotic testing system to a pure moment target of 2.0 Nm for flexion and extension (FE) with no compression and with 100 N of FL. Application of FL was accomplished by loading the specimens with bilateral cables passing through cable guides inserted into the vertebral bodies and attached to load controlled linear actuators. FL significantly increased neutral zone (NZ) stiffness and NZ width but resulted in no change in the range of motion (ROM) or elastic zone stiffness. C45 and C56 IDP measured in the neutral position were significantly increased with application of FL. The change in IDP with increasing flexion rotation was not significantly affected by the application of FL, whereas the change in IDP with increasing extension rotation was significantly reduced by the application of FL. Application of FL did not appear to affect the specimen’s quantity of motion (ROM) but did affect the quality (the shape of the curve). Regarding IDP, the effects of adding FL compression approximates the effect of the patient going from supine to a seated position (FL compression increased the IDP in the neutral position). The change in IDP with increasing flexion rotation was not affected by the application of FL, but the change in IDP with increasing extension rotation was, however, significantly reduced by the application of FL.  相似文献   

7.
Skeletal muscle is a very dynamic tissue, thus accurate quantification of skeletal muscle stiffness throughout its functional range is crucial to improve the physical functioning and independence following pathology. Shear wave elastography (SWE) is an ultrasound-based technique that characterizes tissue mechanical properties based on the propagation of remotely induced shear waves. The objective of this study is to validate SWE throughout the functional range of motion of skeletal muscle for three ultrasound transducer orientations. We hypothesized that combining traditional materials testing (MTS) techniques with SWE measurements will show increased stiffness measures with increasing tensile load, and will correlate well with each other for trials in which the transducer is parallel to underlying muscle fibers. To evaluate this hypothesis, we monitored the deformation throughout tensile loading of four porcine brachialis whole-muscle tissue specimens, while simultaneously making SWE measurements of the same specimen. We used regression to examine the correlation between Young′s modulus from MTS and shear modulus from SWE for each of the transducer orientations. We applied a generalized linear model to account for repeated testing. Model parameters were estimated via generalized estimating equations. The regression coefficient was 0.1944, with a 95% confidence interval of (0.1463–0.2425) for parallel transducer trials. Shear waves did not propagate well for both the 45° and perpendicular transducer orientations. Both parallel SWE and MTS showed increased stiffness with increasing tensile load. This study provides the necessary first step for additional studies that can evaluate the distribution of stiffness throughout muscle.  相似文献   

8.
Tendon or ligament reconstructions often use autologous or allogenic tendons from either extrasynovial or intrasynovial sources. Allograft tendons must be lyophilized for preservation before transplantation, a process which can impact mechanical properties of the graft. Reconstituted graft properties that are similar to native tendon are desirable. Although tensile and compressive properties of tendons have been investigated, there is a paucity of information describing flexural properties of tendon, which can impact the gliding resistance. This study aims to design a testing method to quantify tendon flexural modulus, and investigate the effects of lyophilization/rehydration procedures on tendon flexibility. A total of 20 peroneus longus tendons (extrasynovial) and 20 flexor digitorum profundus tendons (intrasynovial) were collected. Ten of each tendon were processed with 5 freeze–thaw cycles followed by lyophilization and rehydration with saline solution (0.9%). Bend testing was conducted on tendons to quantify the flexural modulus with and without processing. As canine FDP tendons contain fibrous and fibrocartilaginous tissue regions, the flexural moduli were measured in both regions. Flexural modulus of rehydrated, lyophilized extrasynovial PL tendon was significantly lower than that of similarly processed intrasynovial FDP tendon (p < 0.001). Flexural moduli of both the fibrocartilaginous and non-fibrocartilaginous regions of intrasynovial tendon significantly increased after lyophilization (p < 0.001). The flexural modulus of the fibrocartilaginous region was significantly higher than that of the non-fibrocartilaginous region in intrasynovial tendon (p < 0.001). Lyophilization significantly increases the flexural modulus of extrasynovial and intrasynovial tendons, and flexural modulus differs significantly between these two tendon types. Increases in stiffness caused by lyophilization may impact the mechanical performance of the allograft in vivo.  相似文献   

9.
Although the ray‐finned fishes are named for their bony, segmented lepidotrichia (fin rays), we are only beginning to understand the morphological and functional diversity of this key vertebrate structure. Fin rays support the fin web, and their material properties help define the function of the entire fin. Many earlier studies of fin ray morphology and function have focused on isolated rays, or on rays from only one or two fins. At the same time, relatively little is known about how different preservation techniques affect the material properties of many vertebrate structures, including fin rays. Here, we use three‐point bending tests to examine intra‐ and inter‐fin variation in the flexural stiffness of fin rays from yellow perch, Perca flavescens. We sampled fin rays from individuals that were assigned to one of three preservation treatments: fresh, frozen, and preserved with formalin. The flexural stiffness of the fin rays varied within and among fins. Pelvic‐fin rays were the stiffest, and pectoral fin rays the least stiff. The fin rays of the dorsal, anal, and caudal fins all had similar stiffness values, which were intermediate relative to those from the paired fins. The flexural stiffness of the fin rays was higher in rays that were at the leading edge of the fin. This variation in flexural stiffness was associated with variation in joint density and the relative length of the unsegmented proximal base of the fin rays. There was no significant difference in flexural stiffness between fresh and frozen specimens. In specimens preserved with formalin, there is a small but significant effect on stiffness in smaller fin rays.  相似文献   

10.
In vitro tests on the biomechanical properties of human spines are often performed using fresh frozen specimens. However, this carries the risk of pathogen transfer from specimen to the worker and the specimens can only be used for a limited amount of time. Human spinal specimens embalmed with formaldehyde carry an almost absent risk of transfer of pathogens and can be stored and used for a long time, but the tissue properties are strongly affected making this method inapplicable for biomechanical testing. In this study, a new embalming technique called Fix for Life (F4L), which claims to preserve the tissue properties, was tested. The range of motion (ROM) and stiffness of six fresh human spinal specimens was measured using a spinal motion simulator before and after F4L embalming. After F4L embalming, spinal stiffness increased in flexion-extension by 230%, in lateral bending by 284% and in axial rotation by 271%. ROM decreased by 46% in flexion-extension, 56% in lateral bending and 54% in axial rotation. In conclusion, based on this study, F4L does not maintain physiological spinal biomechanical properties, and we propose that this method should not be used for biomechanical studies. Nevertheless, the method may be an alternative to formaldehyde fixation in situations such as training and education because the effect on spinal biomechanics is less detrimental than formaldehyde and tissue color is maintained.  相似文献   

11.
Wind-induced bending loads frequently cause failure of maize (corn) stalks. When failure occurs, it usually manifests as transverse buckling. Because this failure mode is closely related to transverse tissue stiffness, the purpose of this study was to develop a method for measuring the transverse Young’s modulus of maize stalk rind and pith tissues. Short, disc-shaped stalk segments were used for this purpose. X-ray computed tomography was used to obtain the geometry of each specimen prior to testing. Each specimen was tested in two different configurations. Computed tomography data was used to create a specimen-specific finite element model of each test specimen. Data from the first testing configuration was used in conjunction with the finite element model to determine the Young’s Modulus values for each specimen. The specimen-specific finite element models provided estimates of the stress states in the stem under transverse loading, and these stress states accurately predicted the location of failure in transverse test specimens. The entire testing method was validated using data from one test configuration to predict the structural response of each specimen during the second test configuration.  相似文献   

12.
The purpose of this study was to examine the effect of proprioceptive neuromuscular facilitation (PNF) stretching on musculotendinous unit (MTU) stiffness of the ankle joint. Twenty active women were assessed for maximal ankle range of motion, maximal strength of planter flexors, rate of force development, and ankle MTU stiffness. Subjects were randomly allocated into an experimental (n = 10) group or control group (n = 10). The experimental group performed PNF stretching on the ankle joint 3 times per week for 4 weeks, with physiological testing performed before and after the training period. After training, the experimental group significantly increased ankle range of motion (7.8%), maximal isometric strength (26%), rate of force development (25%), and MTU stiffness (8.4%) (p < 0.001). Four weeks of PNF stretching contributed to an increase in MTU stiffness, which occurred concurrently with gains to ankle joint range of motion. The results confirm that MTU stiffness and joint range of motion measurements appear to be separate entities. The increased MTU stiffness after the training period is explained by adaptations to maximal isometric muscle contractions, which were a component of PNF stretching. Because a stiffer MTU system is linked with an improved the ability to store and release elastic energy, PNF stretching would benefit certain athletic performance due to a reduced contraction time or greater mechanical efficiency. The results of this study suggest PNF stretching is a useful modality at increasing a joint's range of motion and its strength.  相似文献   

13.
The influence of pretwist, nonuniformities in mass and flexural stiffness, rotatory inertia and shear deformation on the natural frequencies of intact bones is evaluated by means of a linear elastic, finite-element model which has been programmed for solution on the digital computer. Theoretical results are compared to the results on the forced vibration of intact canine radii obtained experimentally by Thompson. Surprisingly, inclusion of fairly large pretwist angles (from −14° to 12° for one specimen) had little affect on the first three frequencies of transverse vibration in either the cranial or lateral directions. Inclusion of shear deformation reduced the third-mode frequency in the stiffest (lateral) direction by about six per cent, otherwise shear deformation played a minor role in determining natural frequencies. Similarly, rotatory inertia had negligible influence up to the third natural frequency.

The predominant influence on the first three natural frequencies of transverse vibration could be attributed to the variations in mass and flexural stiffness along the length of the test specimens. Different effective moduli of elasticity are required to yield correct absolute values for the frequencies which correspond to experimental findings, thus implying the presence of some inhomogeneities in material properties around the bone cross-section and/or along its length.  相似文献   


14.
The organization of tissues in appendages often affects their mechanical properties and function. In the fish family Labridae, swimming behavior is associated with pectoral fin flexural stiffness and morphology, where fins range on a continuum from stiff to relatively flexible fins. Across this diversity, pectoral fin flexural stiffness decreases exponentially along the length of any given fin ray, and ray stiffness decreases along the chord of the fin from the leading to trailing edge. In this study, we examine the morphological properties of fin rays, including the effective modulus in bending (E), second moment of area (I), segmentation, and branching patterns, and their impact on fin ray stiffness. We quantify intrinsic pectoral fin ray stiffness in similarly sized fins of two closely related species that employ fins of divergent mechanics, the flapping Gomphosus varius and the rowing Halichoeres bivittatus. While segmentation patterns and E were similar between species, measurements of I and the number of fin ray branch nodes were greater in G. varius than in H. bivittatus. A multiple regression model found that of these variables, I was always significantly correlated with fin ray flexural stiffness and that variation in I always explained the majority of the variation in flexural stiffness. Thus, while most of the morphological variables quantified in this study correlate with fin ray flexural stiffness, second moment of area is the greatest factor contributing to variation in flexural stiffness. Further, interspecific variation in fin ray branching pattern could be used as a means of tuning the effective stiffness of the fin webbing to differences in swimming behavior and hydrodynamics. The comparison of these results to other systems begins to unveil fundamental morphological features of biological beams and yields insight into the role of mechanical properties in fin deformation for aquatic locomotion.  相似文献   

15.
The objectives of this study were to obtain linearized stiffness matrices, and assess the linearity and hysteresis of the motion segments of the human lumbar spine under physiological conditions of axial preload and fluid environment. Also, the stiffness matrices were expressed in the form of an 'equivalent' structure that would give insights into the structural behavior of the spine. Mechanical properties of human cadaveric lumbar L2-3 and L4-5 spinal motion segments were measured in six degrees of freedom by recording forces when each of six principal displacements was applied. Each specimen was tested with axial compressive preloads of 0, 250 and 500 N. The displacements were four slow cycles of +/-0.5mm in anterior-posterior and lateral displacements, +/-0.35 mm axial displacement, +/-1.5 degrees lateral rotation and +/-1 degrees flexion-extension and torsional rotations. There were significant increases with magnitude of preload in the stiffness, hysteresis area (but not loss coefficient) and the linearity of the load-displacement relationship. The mean values of the diagonal and primary off-diagonal stiffness terms for intact motion segments increased significantly relative to values with no preload by an average factor of 1.71 and 2.11 with 250 and 500 N preload, respectively (all eight tests p<0.01). Half of the stiffness terms were greater at L4-5 than L2-3 at higher preloads. The linearized stiffness matrices at each preload magnitude were expressed as an equivalent structure consisting of a truss and a beam with a rigid posterior offset, whose geometrical properties varied with preload. These stiffness properties can be used in structural analyses of the lumbar spine.  相似文献   

16.
The purpose of this investigation was to compare the effects of continuous passive motion (CPM) and cast immobilization on postoperative wound healing. Medical parapatellar skin incisions and arthrotomies were performed on both knees of 10 mature New Zealand rabbits. After closure of the incisions, one knee was immobilized in a cast while the other was treated by continuous passive motion for 3 weeks. Six standardized skin specimens (2 mm wide) from each wound were tested to failure and one specimen was examined histologically. With respect to the breaking force, tensile strength, strain at failure, stiffness, and toughness, the wounds in the continuous-passive-motion group were significantly stronger, stiffer, and tougher than those in the cast group. Histologically, the structural organization of the collagen fibers was also superior in the scars treated with continuous passive motion. The results of the present investigation indicate that compared to immobilization, continuous passive motion enhances postoperative wound healing in rabbits.  相似文献   

17.
Intervertebral disc degeneration, a leading cause of low back pain, poses a significant socioeconomic burden with a broad array of costly treatment options. Mechanical loading is important in disease progression and treatment. Connecting mechanics and biology is critical for determining how loading parameters affect cellular response and matrix homeostasis. A novel ex-vivo experimental platform was developed to facilitate in-situ loading of rabbit functional spinal units (FSUs) with relevant biological outcome measures. The system was designed for motion outside of an incubator and validated for rigid fixation and physiologic environmental conditions. Specimen motion relative to novel fixtures was assessed using a digitizer; fixture stiffness exceeded specimen stiffness by an order of magnitude. Intradiscal pressure (IDP), measured using a fiber-optic pressure transducer, confirmed rigidity and compressive force selection. Surrounding media was controlled at 37 °C, 5% O(2)/CO(2) using a closed flow loop with an hypoxic incubator and was validated with probes in the specimen chamber. FSUs were subjected to cyclic compression (20 cycles) and four-hour creep at 1.0 MPa. Disc tissue was analyzed for cell viability using 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT), which showed high viability (>90%) regardless of loading. Conditioned media was assayed for type-II collagen degradation fragments (CTX-II) and an aggrecan epitope (CS-846) associated with new aggrecan synthesis. CTX-II concentrations were not associated with loading, but CS-846 concentrations appeared to be increased with loading. Preservation of the full FSU allows physiologic load transmission and future multi-axis motion and identification of load-responsive proteins, thereby forming a new niche in intervertebral disc organ culture.  相似文献   

18.
BACKGROUND: Interbody arthrodesis is employed in the lumbar spine to eliminate painful motion and achieve stability through bony fusion. Bone grafts, metal cages, composite spacers, and growth factors are available and can be placed through traditional open techniques or minimally invasively. Whether placed anteriorly, posteriorly, or laterally, insertion of these implants necessitates compromise of the anulus--an inherently destabilizing procedure. A new axial percutaneous approach to the lumbosacral spine has been described. Using this technique, vertical access to the lumbosacral spine is achieved percutaneously via the presacral space. An implant that can be placed across a motion segment without compromise to the anulus avoids surgical destabilization and may be advantageous for interbody arthrodesis. The purpose of this study was to evaluate the in vitro biomechanical performance of the axial fixation rod, an anulus sparing, centrally placed interbody fusion implant for motion segment stabilization. METHOD OF APPROACH: Twenty-four bovine lumbar motion segments were mechanically tested using an unconstrainedflexibility protocol in sagittal and lateral bending, and torsion. Motion segments were also tested in axial compression. Each specimen was tested in an intact state, then drilled (simulating a transaxial approach to the lumbosacral spine), then with one of two axial fixation rods placed in the spine for stabilization. The range of motion, bending stiffness, and axial compressive stiffness were determined for each test condition. Results were compared to those previously reported for femoral ring allografts, bone dowels, BAK and BAK Proximity cages, Ray TFC, Brantigan ALIF and TLIF implants, the InFix Device, Danek TIBFD, single and double Harms cages, and Kaneda, Isola, and University plating systems. RESULTS: While axial drilling of specimens had little effect on stiffness and range of motion, specimens implanted with the axial fixation rod exhibited significant increases in stiffness and decreases in range of motion relative to intact state. When compared to existing anterior, posterior, and interbody instrumentation, lateral and sagittal bending stiffness of the axial fixation rod exceeded that of all other interbody devices, while stiffness in extension and axial compression were comparable to plate and rod constructs. Torsional stiffness was comparable to other interbody constructs and slightly lower than plate and rod constructs. CONCLUSIONS: For stabilization of the L5-S1 motion segment, axial placement of implants offers potential benefits relative to traditional exposures. The preliminary biomechanical data from this study indicate that the axial fixation rod compares favorably to other devices and may be suitable to reduce pathologic motion at L5-S1, thus promoting bony fusion.  相似文献   

19.
The renal capsule is an important determinant of whole kidney volume/pressure relationships. To gain further insights into its possible role we examined the mechanical properties of the dog renal capsule using standard materials testing procedures. From each of four locations on the kidney surface, the following mechanical properties of the renal capsule were determined: elastic modulus (force/unit of cross-sectional area theoretically required to double the length of the specimen), tensile stiffness (force/unit width theoretically required to double the length of the specimen), ultimate strength (stress at time of fracture of the specimen), and maximum strain (percent strain at time of the fracture of the specimen). We found that the elastic modulus of the renal capsule from all capsular sites was substantially greater than values previously reported for dog aorta. The stiffness of the capsule covering the anterior-posterior surface of the kidney was found to be about 50% greater than the stiffness of the capsule covering the lateral and polar surfaces of the kidney. The ultimate strength of the anterior-posterior capsule was significantly greater than that of the lateral or polar capsule. This finding may explain the clinical observation that the spontaneous rupture of the renal capsule and parenchyma associated with the acute swelling of transplant rejection is confined almost exclusively to the lateral and polar portions of the renal capsule and cortex. The mean maximum strain at each capsular site was about 35%. This degree of circumferential expansion corresponds to about a doubling of kidney volume. Thus, this observation suggests that the renal capsule is at risk to undergo spontaneous rupture when renal volume increases of this magnitude are observed.  相似文献   

20.
Increased cell number and cell length both contribute to shade induced elongation of petioles which enables stoloniferous plants to place their leaf lamina higher up in the canopy. Although petiole elongation is assumed to be beneficial, it may also imply costs in terms of decreased biomechanical stability. We test the hypothesis that shade induced elongation changes the biomechanical properties of petioles and that the underlying mechanisms, cell division and cell elongation, differentially affect biomechanical properties. This was done by subjecting 14 genotypes differing in the relative contribution of cell size and cell number to shade induced elongation responses to high light conditions and to simulated canopy shade. Developmental traits (cell size and cell number), morphological traits characterizing the petioles, as well as biomechanical characteristics were measured. Our results show that, comparable to stems of non-clonal plants, the rigidity of a petiole’s tissue (the Young’s modulus) increases, leading to increased flexural stiffness of petioles subjected to shading. Increased flexural stiffness proved to be associated with increased performance under shaded conditions. Our results also indicate that cell number affected the material properties and the flexural stiffness of petioles. However, the degree and pattern of the effects differed between light environments. Shade induced increase in cell number translated into shade induced increase of Young’s modulus and flexural stiffness. Genotypes producing relatively larger cells under shaded conditions experienced a decrease in tissue rigidity. In concert our results indicate that the pattern of selection on flexural stiffness, and thereby also on shade induced changes of cell number and cell size differs among light environments. An erratum to this article can be found at  相似文献   