首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
A new rapid and sensitive high-performance liquid chromatographic method for analysis of docetaxel (Taxotere) in human plasma was developed and validated. After adding an internal standard (paclitaxel, Taxol), plasma was extracted following a simple liquid–liquid extraction with diethyl ether. Extraction efficiency averaged 95% for docetaxel. Separation was performed using a Nucleosil (C18) 5 μm column, monitored at 227 nm. The isocratic mobile phase consisted of acetonitrile–acetate buffer, pH 5–tetrahydrofuran (45:50:5, v/v) pumped at a flow-rate of 1.8 ml/min. The limit of quantification for docetaxel in plasma was 12.5 ng/ml. Retention times for docetaxel and paclitaxel were 7.7 and 9 min, respectively. Standard curves were linear over a range of 25–1000 ng/ml. This new method is rapid since it does not require time-consuming extraction procedures, or complex chromatographic conditions. This rapidity, along with the lack of chromatographic interferences with various other drugs likely to be administered to the cancer patients (pain killers, corticoids, antiemetics drugs) make this method suitable for daily routine analysis of Taxotere, a major anticancer drug extensively used in clinical oncology.  相似文献   

2.
This paper describes a simple and sensitive high-performance liquid chromatographic (HPLC) method for the detection of human globin chains in blood and bloodstains. The method involves direct injection of the filtered samples of dilute hemolysates or bloodstain extracts onto a microbore C4 reversed-phase column (2.1 mm I.D.) with UV detection at 220 nm. Microbore HPLC offers a significant improvement in sensitivity with little loss of the resolution of globin chains and only small variations in the determination of γ chain composition. The detection limit of hemoglobin (Hb) was 0.1 μg, which is equivalent to about 1 nl of fresh whole blood. Umbilical cord blood could be differentiated from adult blood in stains that were up to twenty weeks old, by the presence of γ globin chains. The present method will be useful for detection of abnormal Hbs and for the determination of γ chain composition in clinical laboratories, as well as in the practice of forensic science for the analysis of minute amounts of blood and bloodstains.  相似文献   

3.
A high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of aspirin and salicylic acid in transdermal perfusates. The compounds were separated on a C8 Nucleosil column (5 μm, 250×4.6 mm) using a mobile phase containing a mixture of water–acetonitrile–orthophosphoric acid (650:350:2, v/v/v) and a flow-rate of 1 ml/min. The transdermal samples were in phosphate-buffered saline (PBS) and could be injected directly onto the HPLC system. The method was reproducible with inter-day R.S.D. values of no greater than 3.46 and 2.60% for aspirin and salicylic acid, respectively. The method was linear over the concentration range 0.2–5.0 μg/ml and had a limit of detection of 0.05 μg/ml for both compounds. For certain samples, it was necessary to ensure that no transmembrane leakage of the aspirin prodrugs had occurred. In these cases, a gradient was introduced by increasing the acetonitrile content of the mobile phase after the salicylic acid had eluted. The method has been applied to the determination of aspirin and salicylic acid in PBS following in vitro application of the compounds to mouse skin samples.  相似文献   

4.
A simple, specific, and sensitive high-performance liquid chromatographic (HPLC) method for the determination of riboflavin directly in urine samples using a fixed-wave-length spectrofluorometer is described. Centrifuged raw urine samples (50 μl) are injected onto a reversed-phase microparticulate C18 column. The eluent is 0.01 M KH2PO4 (pH 5.0)—methanol (65:35). This method is capable of differentiating riboflavin from riboflavin-5-phosphate, non-riboflavin fluorescing components in urine, and photo-degraded riboflavin. The method shows good reproducibility and is linear to at least 12 μg/ml. The sensitivity of this procedure, at the 95% confidence limit, determined by linear regression analysis, is estimated to be 0.05 μg/ml using peak height and 0.07 μg/ml using peak area. This HPLC method is compared to an automated fluorometric method for riboflavin. The coefficient of linear regression of this comparison is Y = 0.858 + 0.893X, where X is the HPLC method and Y is the fluorometric method.  相似文献   

5.
A rapid and simple method for the determination of α1-acid glycoprotein (AAG) in serum was developed by using an anion-exchange column for clean-up of serum and a hydroxyapatite column for high-performance liquid chromatography (HPLC). A good correlation was observed between this HPLC method and the conventional radial immunodiffusion method. The method may also be used to determine the AAG concentration in the serum of experimental animals.  相似文献   

6.
A high-performance liquid chromatographic (HPLC) assay was developed for the determination of chlorpromazine in serum and human breast milk. Chlorpromazine in serum and human breast milk was extracted by a rapid and simple procedure based on C18 bonded-phase extraction, and a reversed-phase HPLC separation technique was developed. Chlorpromazine and levomepromazine as the internal standard were detected by ultraviolet absorbance at 254 nm. Determination was possible for chlorpromazine in the concentration range 10–300 ng/ml. The recoveries of chlorpromazine added to serum and human breast milk were 80.1–87.6 and 80.3–84.4%, respectively, with coefficients of variation of less than 10.2 and 7.8%. The method is applicable to drug level monitoring in the serum and human breast milk of patients treated with chlorpromazine.  相似文献   

7.
Local transcutaneous delivery of non-steroidal anti-inflammatory drugs avoids gastrointestinal side effects and concentrates drugs in the intended tissues. An extraction and HPLC method was developed for ketoprofen in skin, fascia and muscle. Tissue samples were homogenized in NaHCO3. After methylene chloride removal of lipids, the aqueous layer was acidified with HCl and back extracted into isooctane/isopropanol. Ketoprofen was derivatized with ethylchloroformate/S-(−)-α-phenylethylamine in triethylamine, then detected by HPLC. Ketoprofen recovery was linear (1–33 μg/g) and was detected in these tissues following in vivo cathodic iontophoresis (160 mA*min). This represents the first non-radioactive method for determination of ketoprofen in tissues following transcutaneous iontophoresis.  相似文献   

8.
A sensitive method for the enantioselective high-performance liquid chromatography (HPLC) determination of nicardipine in human plasma is described. (+)-Nicardipine, (−)-nicardipine and (+)-barnidipine as an internal standard are detected by an ultraviolet detector at 254 nm. Racemic nicardipine in human plasma was extracted by a rapid and simple procedure based on C18 bonded-phase extraction. The extraction samples were purified and concentrated on a pre-column using a C1 stationary phase and the enantiomers of nicardipine are quantitatively separated by HPLC on a Sumichiral OA-4500 column, containing a chemically modified Pirkle-type stationary phase. Determination of (+)- and (−)-nicardipine was possible in a concentration range of 5–100 ng ml−1 and the limit of detection in plasma was 2.5 ng ml−1. The recoveries of (+)- and (−)-nicardipine added to plasma were 91.4–98.4% and 93.3–96.7%, respectively, with coefficients of variation of less than 9.0 and 9.4% respectively. The method was applied to low level monitoring of (+)- and (−)-nicardipine in plasma from healthy volunteers.  相似文献   

9.
10.
A sensitive and selective method for the determination of cefuroxime in bronchoalveolar lavage (BAL) fluid using high-performance liquid chromatography (HPLC) with UV detection at 280 nm after solid-phase extraction with C18 cartridges was developed. A Waters symmetry C18 column was used and the mobile phase was acetonitrile-0.05 M ammonium phosphate buffer (pH 3.2) (15:85, v/v). The method enabled the determination of cefuroxime at concentrations below 100 ng/ml, with a linear calibration curve at concentrations of 5–100 ng/ml for 400 μl of BAL. The intra- and inter-assay coefficient of variations for 10, 40 and 80 ng/ml were between 5.3 and 8.9%. Analytical recoveries were between 92.7 and 106.2%. The detection limit was 1 ng/ml at a signal-to-noise ratio of 3:1 using 400 μl of BAL. The method was successfully used for the analysis of BAL fluid from patients after oral administration of 500 mg cefuroxime axetil twice daily.  相似文献   

11.
We established a high-performance liquid chromatography (HPLC) method for the simultaneous determination of the camptothecin (CPT) derivative, irinotecan hydrochloride (CPT-11) and its metabolites, 7-ethyl-10-hydroxycamptothecin (SN-38) and SN-38 glucuronide (SN-38G) in rat plasma with a fully automated on-line solid-phase extraction system, PROSPEKT. Plasma samples were pretreated with 0.146 M H3PO4 to inactivate carboxylesterase and β-glucuronidase in rat plasma, and added with the internal standard solution (0.146 M H3PO4 containing 1 μg/ml CPT) and then analyzed. The method was validated for CPT-11 (5 to 25 000 ng/ml), SN-38 (5 to 2500 ng/ml) and SN-38G (2.5 to 500 ng/ml). This method enabled the determination of many samples within a relatively short time with easy sample preparation. It also had four advantages compared with conventional determination methods, i.e. automation of a complicated sample preparation, time-saving by the simultaneous determination of three compounds, the direct determination of SN-38G, and the small amount of plasma required for the determination.  相似文献   

12.
A reliable high-performance liquid chromatographic (HPLC) method which allows the determination in human urine of two important metabolites of N,N-dimethylformamide (DMF), namely N-methylformamide (MMF) and N-methyl-N-(hydroxymethyl)formamide (DMFOH), is reported. A single-step rapid purification of urine was performed on a C18 solid-phase extraction column and the eluate was injected directly on to the HPLC column. HPLC was carried out isocratically on Aminex Ion Exclusion HPX-87H column using 7.5 · 10−4 M sulphuric acid as the mobile phase with ultraviolet detection at 196 nm. The method is specific, accurate, precise and sufficiently sensitive to be applied to the biological monitoring of MMF and DMFOH in workers exposed to DMF.  相似文献   

13.
A method for the determination of isonicotinic acid hydrazide (isoniazid) in milk was developed. Milk was deproteinized with trichloroacetic acid. Isoniazid was condensed with cinnamaldehyde and assayed on a reversed-phase HPLC system, with good sensitivity and accuracy (10 μg/l) with UV detection at 330 nm. Use of solid-phase extraction with a C18 cartridge allows the detection limit to be lowered to 0.1 μg/l with UV detection and confirmation of isoniazid hydrazone from the diode-array UV spectrum.  相似文献   

14.
The zearalenone (ZEA) monoclonal antibody (mAb) 2D3, one of the highest sensitivity antibodies, was developed. Based on this mAb, it was established of an immunoaffinity column (IAC) coupled with an indirect competitive enzyme-linked immunosorbent assay (icELISA). After optimization, the icELISA allowed an IC50 against ZEA of 0.02 µg L−1. The mAb 2D3 exhibited a high recognition of ZEA (100%) and β-zearalenol (β-ZOL, 88.2%). Its cross-reactivity with α-zearalenol (α-ZOL) and β-zearalanol (β-ZAL) were found to be 4.4% and 4.6%, respectively. The IAC-icELISA method was employed to analyze ZEA contamination in food samples, compared with high-performance liquid chromatography (HPLC). The spiked assay for ZEA demonstrated the considerable recoveries for IAC-icELISA (83–93%) and HPLC (94–108%) methods. Results showed that the mAb 2D3 and IAC-icELISA method posed potential applications in sensitively determination of ZEA in maize.  相似文献   

15.
A column-switching method was developed for the determination of total 3-methoxy-4-hydroxy-phenylethyleneglycol (MHPG) in urine. This was performed by first treating samples with β-glucuronidase, followed by extraction with ethyl acetate. The reconstituted extracts with injected onto an HPLC system containing an amperometric detector and tandem Nucleosil C18 and C8 reversed-phase columns connected by a switching valve. The total analysis time for MHPG was 12 min. The limit of detection was 0.18 ng, or 9 μg/l for 20-μl injections of a 1.0-ml reconstituted extract prepared from 1.0 ml of urine. The linear range extended up to 80 mg/l. The within-day precision for a urine sample containing 170 μg/l total MHPG was ±6% and the day-to-day precision was ±15%. The average levels determined by this method for total MHPG in normal subjects showed good agreement with previous literature values. This approach could be modified for the determination of free MHPG by using only ethyl acetate extraction for sample pretreatment.  相似文献   

16.
A selective HPLC method is described for the determination of cefpodoxime levels in plasma and sinus mucosa. Sample preparation included solid-phase extraction with a C8 cartridge. Cefpodoxime and cefaclor (internal standard) were eluted with methanol and analyzed on an optimised system consisting of a C18 stationary phase and a ternary mobile phase (0.05 M acetate buffer pH 3.8—methanol—acetonitrile, 87:10:3, v/v) monitored at 235 nm. Linearity and both between- and within-day reproducibility were assessed for plasma and sinus mucosa samples. Inter-assay coefficients of variation were lower than 13.6% (n = 10) for plasma (0.2 μg/ml) and lower than 12.4% (n = 5) for sinus mucosa (0.25 μg/g). The quantification limit was 0.05 μg/ml for plasma and 0.13 μg/g for tissue. The method was used to study the diffusion of cefpodoxime in sinus mucosa.  相似文献   

17.
A method is described for the determination of celecoxib in human plasma. Samples were extracted using 3M Empore membrane extraction cartridges and separated under normal-phase HPLC conditions using a Nucleosil-NO2 (150×4.6 mm, 5 μm) column. Detection was accomplished using UV absorbance at 260 nm. The HPLC method included a column switching procedure, in which late eluting compounds were diverted to waste, to reduce run-time to 12 min. The assay was linear in the concentration range of 25–2000 ng/ml when 1-ml aliquots of plasma were extracted. Recoveries of celecoxib were greater than 91% over the calibration curve range. Intraday precision and accuracy for this assay were 5.7% C.V. or better and within 2.3% of nominal, respectively. The assay was used to analyze samples collected during human clinical studies.  相似文献   

18.
A highly sensitive method for the determination of cholesterol in biological fluids is described. Unsaponifiable lipids from rat serum and thoracic duct lymph chylomicron samples were treated with cholesterol oxidase. The product of the enzymatic reaction, Δ4-cholestenone, was analysed by normal-phase high-performance liquid chromatography (HPLC) using hexane—isopropanol (95:5, v/v) as a mobile phase and detected with a UV spectrophotometer at 240 nm. When the standard samples containing varying amounts of cholesterol (0.15–3 nmol) were treated with cholesterol oxidase and analysed by HPLC (injected amounts 0.09–1.8 nmol of cholesterol), the peak areas increased proportionally with the amounts of authentic cholesterol with a correlation coefficient of 0.996. The values in these biological fluids determined by the HPLC method were identical to those obtained by enzymatic—colorimetric or gas chromatographic methods. Moreover, the detection limit (0.09 nmol) of the present method (0.15 nmol are required for the sample preparation) is lower than those of conventional methods (approximately 30 nmol). Because of the excellent sensitivity and reproducibility, this method is well suited for the determination of cholesterol in biological fluids where cholesterol concentration is low.  相似文献   

19.
A high-performance liquid chromatographic (HPLC) method based on solid-phase extraction (SPE) was developed for determination of amoxicillin, penicillin G (benzylpenicillin), ampicillin, oxacillin, cloxacillin, nafcillin and dicloxacillin in muscle, liver and kidney tissues of pigs and cattle. The compounds were extracted in aqueous solution by precipitation of organic materials with a mixture of sulphuric acid and sodium tungstate. The extract was cleaned up by SPE on a divinylbenzene-co-N-vinylpyrrolidone polymeric sorbent. Further clean-up was performed by liquid–liquid partition with diethyl ether. The extract was derivatised with benzoic anhydride and 1,2,4-triazole mercury (II) reagent. Chromatography was performed by reversed-phase gradient HPLC on a C18 column with ultraviolet detection at 323 nm. The limits of detection estimated by a conservative model were in the range 8.9–11.1 μg/kg for amoxicillin, penicillin G, ampicillin, oxacillin, cloxacillin and nafcillin and 18.3–20.9 μg/kg for dicloxacillin. The mean recovery range was 66–77% for amoxicillin, 73–75% for penicillin G, 81–82% for ampicillin, 73–76% for oxacillin, 74–75% for cloxacillin, 66–72% for nafcillin and 58–65% for dicloxacillin.  相似文献   

20.
An improved method suitable for the determination of 8-methoxypsoralen in the range 50–1500 ng/ml in the plasma of psoriatic patients undergoing PUVA (psoralens and long-wave ultraviolet light) therapy is proposed. A 5-ml aliquot of plasma containing sodium citrate as anticoagulant was centrifuged, griseofulvin was added as internal standard and the sample was denatured with acetonitrile. The supernatant was applied to C18 cartridges and 8-methoxypsoralen was eluted with methanol. The evaporated eluate was reconstituted in the mobile phase for high-performance liquid chromatography (HPLC) and applied to the HPLC column: mobile phase, acetonitrile—0.01 M phosphoric acid (34:66); flow-rate, 1 ml/min; temperature, 40°C; column, Spherisorb 5 ODS, 100 mm × 4.6 mm I.D., 5 μm particle size; UV detection at 248 nm; detection limit, 15 ng/ml of plasma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号