首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Dried blood spots (DBSs) technology was evaluated in an assay for the quantitation of dextromethorphan (DM) and its metabolite, dextrorphan (DT), in human whole blood using high performance liquid chromatography with tandem mass spectrometry method (LC–MS/MS). Both the parent drug and metabolite were spiked in the blood matrix and subsequently allowed to dry on a specimen collection card. The dried blood spots were removed using a manual punch and then extracted into methyl tert-butyl ether (MTBE). The organic supernatant was transferred and evaporated and the residue was reconstituted in 20% acetonitrile. The overall method recovery of DM and DT was 87.8% and 95.4%, respectively. The assay was linear over the concentration range of 0.2–200 ng/mL for both analytes. Several factors that potentially affect DBS assay quantitation were investigated, such as punch size, DBS sample punch-out location, and the volume of the blood sample pipetted on the specimen collection cards. The study determined that punch size does not affect assay quantitation accuracy. Indeed, a larger punch size increases the sensitivity due to the larger sampled blood spots. Sampling from different location on the specimen collection cards shows no significant variation for both drugs. The study also shows that acceptable results can be achieved with some variation of the sample volume, which allows a simple blood sampling procedure at the test sites. To achieve the similar lower limit of quantitation (LLOQ) as the plasma assay, several blood spots at the same concentration level were stacked together and extracted. Bioanalytical assays using the DBS technique are promising given the advantages of the method over the plasma assay.  相似文献   

2.
Moxifloxacin (MFX) is a potential oral agent use in the treatment of multidrug-resistance tuberculosis (MDR-TB). Due to variability in pharmacokinetics and in vitro susceptibility of causative bacteria, therapeutic drug monitoring (TDM) of MFX is recommended. Conventional plasma sampling for TDM is facing logistical challenges, especially in limited resource areas, and dried blood spots (DBS) sampling may offer a chance to overcome this problem. The objective of this study was to develop a LC-MS/MS method for determination of MFX in dried blood spots (DBS) that is applicable for TDM. The influence of paper type, the hematocrit (Hct) and the blood volume per spot (V(b)) on the estimated blood volume in a disc (V(est)) was investigated. The extracts of 8mm diameter discs punched out from DBS were analyzed using liquid chromatography tandem mass spectrometry (LC-MS/MS) with cyanoimipramin as internal standard. The method was validated with respect to selectivity, linearity, accuracy, precision, sensitivity, recovery and stability. The effect of Hct and V(b) on LC-MS/MS analytical result was also investigated. The relationship between MFX concentrations in venous and finger prick DBS and those in plasma was clinically explored. V(est) was highly influenced by Hct while the effect of V(b) appeared to be different among paper types. Calibration curves were linear in the range of 0.05-6.00 mg/L with inter-day and intra-day precisions and biases of less than 11.1%. The recovery was 84.5, 85.1 and 92.6% in response to blood concentration of 0.15, 2.50 and 5.00 mg/L, respectively. A matrix effect of less than 11.9% was observed. MFX in DBS was stable for at least 4 weeks at room condition (temperature of 25°C and humidity of 50%). A large range of Hct value produced a significant analytical bias and it can be corrected with resulting DBS size. A good correlation between DBS and plasma concentrations was observed and comparable results between venous DBS and finger prick DBS was attained. This fully validated method is suitable for determination of MFX in dried blood spot and applicable for TDM.  相似文献   

3.
As laboratories are called upon to develop novel, fast, and sensitive methods, here we present a completely automated method for the analysis of cocaine and its metabolites (benzoylecgonine, ecgonine methyl ester, ecgonine and cocaethylene) from whole blood. This method utilizes an online solid-phase extraction (SPE) with high performance liquid chromatographic separation and tandem mass spectrometric detection. Pretreatment of samples involve only protein precipitation and ultracentrifugation. An efficient online solid-phase extraction (SPE) procedure was developed using Hysphere MM anion sorbent. A gradient chromatography method with a Gemini C6-Phenyl (50mmx3.00mm i.d., 5microm) column was used for the complete separation of all components. Analysis was by positive ion mode electrospray ionization tandem mass spectrometry, using multiple reaction monitoring (MRM) to enhance the selectivity and sensitivity of the method. For the analysis, two MRM transitions are monitored for each analyte and one transition is monitored for each internal standard. With a 30-microL sample injection, linearity was analyte dependent but generally fell between 8 and 500ng/mL. The limits of detection (LODs) for the method ranged from 3 to 16ng/mL and the limits of quantitation (LOQs) ranged from 8 to 47ng/mL. The bias and precision were determined using a simple analysis of variance (ANOVA: single factor). The results demonstrate bias as <7%, and %precision as <9% for all components at each QC level.  相似文献   

4.
Wang C  Zhang W  Song F  Liu Z  Liu S 《Amino acids》2012,42(5):1889-1895
The analysis by electrospray-ionization tandem mass spectrometry of amino acids with butyl esterification and isotopically labeled internal standard is routine in newborn screening laboratories worldwide. In the present study, we established a direct analysis method of higher accuracy that uses a non-deuterated internal standard. The automatic sampler and the pump of an LC apparatus were used to inject sample and mobile phase to MS, but no LC column was needed. The dry blood spot (DBS) material was prepared at levels of low, medium and high concentration; the running time was 1 min. In parallel to the new procedure, we applied the established method to analyze nine amino acids on DBS of healthy newborns and phenylketonuria newborns. The newly proposed method of product ion confirmation scan along with multiple reaction monitoring resulted in a very accurate identification of each amino acid. Our innovative protocol had high sensitivity and specificity in the analysis of cases of suspected metabolic diseases.  相似文献   

5.
Sirolimus is a widely used immunosuppressant that requires therapeutic drug monitoring (TDM). We optimized a preanalytical procedure that allows for the accurate quantiation of sirolimus in whole blood by LC/ESI-MS/MS with minimal matrix effects. Sirolimus is highly lipophilic, and solvents containing greater than 50% methanol were required to maintain sirolimus recovery. The final pretreatment procedure developed consists of a zinc sulfate protein precipitation, an extraction using octadecyl silyl-silica gel for eliminating water-soluble and hydrophilic compounds, and HybridSPE cartridge treatment to eliminate phospholipids. Using this procedure prior to LC/ESI-MS/MS led to the accurate and reproducible quantitation of sirolimus in human whole blood. The linear range of detection was 0.5-50 ng/mL, a range appropriate for TDM, and the method demonstrated good repeatability and intermediate precision within this quantitative range. In order to investigate the quantitative performance of this method, we compared it to two commercially available sirolimus immunoassays and our previously reported LC/ESI-MS/MS method. The immunoassays gave consistently greater values for the sirolimus concentration, and this may be related to antibody cross-reactivity with sirolimus metabolites and/or other matrix effects. Although our procedure is too long to support real-time TDM for outpatients, it can serve as reference method to assess the performance of other analytical methods that are currently available or may be developed in the future.  相似文献   

6.
A reversed phase HPLC-MS/MS method has been developed and validated for the quantitative bioanalysis of acetaminophen in dried blood spots (DBS) prepared from small volumes (15 microL) of dog blood. Samples were extracted for analysis with methanol. Detection was by positive ion TurboIonSpray ionisation combined with selected reaction monitoring MS. The analytical concentration range was 0.1-50 microg/mL. The intra-day precision and bias values were both less than 15%. Acetaminophen was stable in DBS stored at room temperature for at least 10 days. The methodology was applied in a toxicokinetic (TK) study where the data obtained from DBS samples was physiologically comparable with results from duplicate blood samples (diluted 1:1 (v/v) with water) analysed using identical HPLC-MS/MS conditions. This work demonstrates that quantitative analysis of a drug extracted from DBS can provide high quality TK data while minimising the volume of blood withdrawn from experimental animals, to an order of magnitude lower than is current practice in the pharmaceutical industry. This is the first reported application of DBS analysis to a TK study in support of a safety assessment study. The success of this and similar, related studies has led to the intent to apply DBS technology as the recommended analytical approach for the assessment of pharmacokinetics (PK)/TK for all new oral small molecule drug candidates, which have previously demonstrated a successful bioanalytical validation.  相似文献   

7.
An amino group of phosphatidylethanolamine (PE) is considered as a target for nonenzymatic glycation, and the potential involvement of lipid glycation in the pathogenesis of diabetic complications has generated interest. However, unlike an early glycation product of PE (Amadori-PE), the occurrence and roles of advanced glycation end products of PE (AGE-PE) in vivo have been unclear. Here, we developed an LC-MS/MS method for the analysis of AGE-PE [carboxymethyl-PE (CM-PE) and carboxyethyl-PE (CE-PE)]. Collision-induced dissociation of CM-PE and CE-PE produced characteristic ions, permitting neutral loss scanning (NLS) and multiple reaction monitoring (MRM) of AGE-PE. By NLS analysis, a series of AGE-PE molecular species was detected in human erythrocytes and blood plasma. In LC-MS/MS analysis, MRM enabled the separation and determination of the predominant AGE-PE species. Between healthy subjects and diabetic patients, no significant differences were observed in AGE-PE concentrations in erythrocytes and plasma, whereas Amadori-PE concentrations were higher in diabetic patients. These results provide direct evidence for the presence of AGE-PE in human blood, and indicated that, compared with Amadori-PE, AGE-PE is less likely to be accumulated in diabetic blood. The presently developed LC-MS/MS method appears to be a powerful tool for understanding in vivo lipid glycation and its pathophysiological consequence.  相似文献   

8.
Summary Amplification of DNA recovered from a dried blood spot was used to genotype individuals with sickle cell disease, sickle cell carriers, and controls. A single 200-l blood spot applied to a filter paper provides sufficient material for more than 20 genetic analyses. In addition, the stability of the DNA is such that adequate material for amplification can be isolated from dried blood spots up to a year following collection. The DNA analysis methods described in this study could be applied to large-scale screening of newborns for genetic disorders.  相似文献   

9.
Vincristine is a natural vinca alkaloid widely used in paediatric cancer treatment. Vincristine pharmacokinetics has been already studied, but few data are available in paediatric populations. A sensitive and specific liquid chromatography–tandem mass spectrometry (LC/MS/MS) method was developed for the quantification of vincristine in plasma in order to investigate pharmacokinetics in a paediatric population. Two hundred microliters of plasma was added to vinblastine, used as internal standard. Chromatographic separation was achieved on a C8 HPLC column (Phenomenex Luna 50 mm × 2.0 mm, 3.0 μm) with a mobile phase gradient at a flow rate of 0.2 ml/min. Quantification was performed using the transition of 825.4  765.4 (m/z) for vincristine and 811.4  751.4 (m/z) for vinblastine. Chromatographic separation was achieved in 8 min. The limit of quantification was 0.25 ng/ml with a precision of 10.2% and an accuracy of 99.6%. The calibration curve was linear up to 50.0 ng/ml. Intra-day precision and accuracy ranged from 6.3% to 10% and from 91.9% to 100.8%, respectively. Inter-assay precision and accuracy ranged from 3.8% to 9.7% and from 93.5% to 100.5%, respectively. No significant matrix effect was observed for vincristine. A rapid, specific and sensitive LC/MS/MS method for quantification of vincristine in human plasma was developed and is now successfully applied for pharmacokinetic studies in paediatric patients.  相似文献   

10.
11.
A simple and fast procedure was developed for the simultaneous determination of eight benzodiazepines (BZDs) in whole blood using liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS). Sample pretreatment was carried out using a simple liquid-liquid extraction (LLE) with n-butylchloride, and chromatographic separation was performed using a monolithic silica column to speed up the analytical process. APCI and electrospray ionization (ESI) were compared. Whereas both ionization techniques appeared suitable for BZDs, APCI was found to be slightly more sensitive, especially for the determination of frequently low-dosed compounds. The method was validated according to the guidelines of the "Société Fran?aise des Sciences et Techniques Pharmaceutiques" (SFSTP) in the concentration range of 2.5-500 microg/L. The limit of quantification (LOQ) was 2.5 microg/L for all the compounds. Validation data including linearity, precision, and trueness were obtained, allowing subtherapeutic quantification of frequently low-dosed BZDs. The high selectivity of the mass spectrometer, along with the properties of the monolithic support, allowed unequivocal analysis of the eight compounds in less than 5 min. To demonstrate the potential of the method, it was used for the analysis of benzodiazepines in postmortem blood samples.  相似文献   

12.
A cost-effective HPLC method for determination of pyrimethamine (PYR) in human whole blood samples dried on filter paper (Whatman) is reported. Trimethoprim (TMP) was used as an internal standard. Whole blood spiked with PYR was transferred (100 microl) onto filter paper and dried at room temperature. Capillary blood samples (100 microl) after ingestion of three tablets of sulfadoxine-pyrimethamine (SP) by one subject were also tested. PYR and an internal standard (IS) TMP were extracted into di-isopropyl ether as bases and then re-extracted with 150 microl mobile phase. A C-18 column was used and the mobile phase consisted of phosphate buffer (0.05 M, pH 5):acetonitrile:concentrated perchloric acid (750:300:2.5, v/v/v). The absorbances of PYR and IS were monitored at 270 nm. The limit of quantification was 40 ng/ml. The within- and between-assay coefficient of variations were <10% at the limit of quantification.  相似文献   

13.
High-performance liquid chromatography (HPLC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) are generally accepted as the preferred techniques for detecting and quantitating analytes of interest in biological matrices on the basis of the rule that one chemical compound yields one LC-peak with reliable retention time (Rt.). However, in the current study, we have found that under the same LC-MS conditions, the Rt. and shape of LC-peaks of bile acids in urine samples from animals fed dissimilar diets differed significantly among each other. To verify this matrix effect, 17 authentic bile acid standards were dissolved in pure methanol or in methanol containing extracts of urine from pigs consuming either breast milk or infant formula and analyzed by LC-MS/MS. The matrix components in urine from piglets fed formula significantly reduced the LC-peak Rt. and areas of bile acids. This is the first characterization of this matrix effect on Rt. in the literature. Moreover, the matrix effect resulted in an unexpected LC behavior: one single compound yielded two LC-peaks, which broke the rule of one LC-peak for one compound. The three bile acid standards which exhibited this unconventional LC behavior were chenodeoxycholic acid, deoxycholic acid, and glycocholic acid. One possible explanation for this effect is that some matrix components may have loosely bonded to analytes, which changed the time analytes were retained on a chromatography column and interfered with the ionization of analytes in the MS ion source to alter the peak area. This study indicates that a comprehensive understanding of matrix effects is needed towards improving the use of HPLC and LC-MS/MS techniques for qualitative and quantitative analyses of analytes in pharmacokinetics, proteomics/metabolomics, drug development, and sports drug testing, especially when LC-MS/MS data are analyzed by automation software where identification of an analyte is based on its exact molecular weight and Rt.  相似文献   

14.
A mass spectrometry-based antibody selection procedure was developed to evaluate optimal 'capture' monoclonal antibodies that can be used in a variety of analytical measurement applications. The isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) methodology is based on the use of multiple-reaction monitoring of tryptic peptide fragments derived from protein antigens. A panel of monoclonal antibodies (mAb) was evaluated based on a quantitative determination of relative binding affinity to human cardiac troponin I following immunoprecipitation. Dissociation constants (K(d)) were determined for 'bound mAb-antigen' vs. 'unbound antigen' using non-linear regression analysis. Relative quantification of both antigen and antibody was based on the use of stable isotope-labeled synthetic peptides as internal standards. Optimal 'capture' mAbs were determined through evaluation of relative K(d) constants of all monitored peptide transitions. A panel of six pre-screened candidate capture mAbs was concluded to consist of two subsets of mAbs, each with statistically equivalent K(d) constants as determined using NIST Standard Reference Material (SRM) 2921 - Human Cardiac Troponin Complex. This ID LC-MS/MS method is shown to be capable of quantitatively differentiating mAbs based on relative binding affinities. Selection of optimal capture mAbs can be applied toward a number of analytical applications which require metrological traceability and unbiased quantification.  相似文献   

15.

Introduction

For pediatric diseases like childhood leukemia, a short latency period points to in-utero exposures as potentially important risk factors. Untargeted metabolomics of small molecules in archived newborn dried blood spots (DBS) offers an avenue for discovering early-life exposures that contribute to disease risks.

Objectives

The purpose of this study was to develop a quantitative method for untargeted analysis of archived newborn DBS for use in an epidemiological study (California Childhood Leukemia Study, CCLS).

Methods

Using experimental DBS from the blood of an adult volunteer, we optimized extraction of small molecules and integrated measurement of potassium as a proxy for blood hematocrit. We then applied this extraction method to 4.7-mm punches from 106 control DBS samples from the CCLS. Sample extracts were analyzed with liquid chromatography—high resolution mass spectrometry (LC-HRMS) and an untargeted workflow was used to screen for metabolites that discriminate population characteristics such as sex, ethnicity, and birth weight.

Results

Thousands of small molecules were measured in extracts of archived DBS. Normalizing for potassium levels removed variability related to varying hematocrit across DBS punches. Of the roughly 1000 prevalent small molecules that were tested, multivariate linear regression detected significant associations with ethnicity (three metabolites) and birth weight (15 metabolites) after adjusting for multiple testing.

Conclusions

This untargeted workflow can be used for analysis of small molecules in archived DBS to discover novel biomarkers, to provide insights into the initiation and progression of diseases, and to provide guidance for disease prevention.
  相似文献   

16.
Quaternary ammonium drugs (atracurium, bretylium, edrophonium, ipratropium, mivacurium, neostigmine, pancuronium and rocuronium) and herbicides (difenzoquat, diquat and paraquat) in human whole blood were analysed by LC/MS/MS with positive electrospray ionisation (ESI), following extraction with Bond Elut LRC-CBA cartridges. Internal standards were benzyldimethylphenylammonium chloride monohydrate and ethyl viologen for drug and herbicide analysis, respectively. Ion-pair chromatography used heptafluorobutyric acid (15 mM)-ammonium formate (20 mM) buffer adjusted to pH 3.30 with formic acid and a linear gradient from 5 to 90% methanol run over 18 min. Recoveries ranged from 79.7 to 105.1%, detection limits were between 3.6 and 20.4 ng/ml and the intra- and inter-day precisions were less than 18.6% at a concentration of 10 ng/ml. The method was applied to a case of accidental paraquat poisoning in which the concentration of paraquat in blood was 0.64 mg/l, which is within the range associated with fatal paraquat poisoning.  相似文献   

17.
A rapid, accurate, and reproducible liquid chromatography electrospray tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated for the therapeutic drug monitoring of voclosporin in human whole blood. Sample aliquots of 100muL were processed utilizing a protein precipitation procedure that contained a mixture of methanol, 0.2M ZnSO(4), and deuterated voclosporin internal standard. Supernatant was injected onto a Zorbax SB-C8, 2.1x12.5mm column (at 60 degrees C), and washed with water-acetonitrile, supplemented with 0.02% glacial acetic acid and 0.02mM sodium acetate, to remove poorly retained components. After washing, water-MeOH (with 0.02% glacial acetic acid and 0.02mM sodium acetate) was used to elute the voclosporin and internal standard to the Applied Biosystems/MDS-Sciex API3000 mass spectrometer for detection in multiple reaction monitoring. Analytical performance was assessed in the range of 1-200ng/ml in whole blood. This method has been used to quantify concentrations of voclosporin in whole blood from healthy volunteers participating in a pharmacokinetic study.  相似文献   

18.
An LC-MS/MS method has been developed for the quantitative determination of a protein drug (Tenecteplase; M(W) 58,777 Da) in rat plasma. The protein was digested with trypsin without prior clean-up of the plasma sample, without the use of a label nor internal standard. A limited validation was performed to assess the linearity, the sensitivity and the specificity of the method. In addition, the developed method was applied to the quantitative analysis of Tenecteplase in rat plasma samples originating from a single-dose study in rats.  相似文献   

19.
An evaporation-free solid-phase extraction (SPE) method was developed and validated for sumatriptan. High organic washing (50% methanol) and low organic elution (20% methanol) were used and the recovery was greater than 92%. The eluate was injected into a C18 column without evaporation and reconstitution. Sumatriptan was monitored in positive ion mode with mass transition of m/z 296.4-58.1 amu. The calibration curve was 1-100 ng/mL (r>or=0.9923). The inter-day and intra-day precisions ranged from 4.53 to 9.12% and 1.72 to 6.93%, respectively. This method features reduced cost and pollution, clean extract, high speed, and most importantly overall method reliability.  相似文献   

20.
A sensitive and rapid LC-MS/MS method was developed and validated for the determination of levamisole in human plasma. The assay was based on liquid-liquid extraction of analytes from human plasma with ethyl ether. Chromatographic separation was carried on an Agilent HC-C(8) column (150 mm × 4.6 mm, 5 μm) at 40°C, with a mobile phase consisting of acetonitrile-10 mM ammonium acetate (70:30, v/v), a flow rate of 0.5 mL/min and a total run time of 6 min. Detection and quantification were performed by mass spectrometry in the multiple reaction monitoring mode with positive electrospray ionization m/z at 205.1→178.2 for levamisole, and m/z 296.1→264.1 for mebendazole (internal standard). The assay was linear over a concentration range of 0.1-30 ng/mL with a lower limit of quantification of 0.1 ng/mL. The coefficient of variation of the assay precision was less than 8.5%. The assay was successfully used to analyze human plasma samples in a pharmacokinetic study where levamisole was administered as a liniment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号