首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Entamoeba histolytica actually comprises two genetically distinct but morphologically indistinguishable species. E. histolytica can cause invasive intestinal and extra intestinal disease, while E. dispar cannot. Identification and differentiation of E. dispar and E. histolytica in stool sample by microscopy is imprecise. Several weeks of culture and isoenzyme analysis are required to differentiate E. histolytica from E. dispar. In this study, we have used an enzyme-linked immunosorbent assay (ELISA) for detection of E. histolytica/E.dispar and compared it with microscopy. Eighty-eight samples were evaluated, trichrome staining was positive in 20.4% (18) and ELISA was positive in 29.5% (26). Both tests were positive in 14 (15.9%) samples, 4 (4.5%) only with direct microscopy, and 12 (13.6%) only with ELISA. Both tests were negative in 58 (65.9%) samples. Microscopy has low sensitivity and high specificity, low negative predictive value and high positive predictive value in comparison with ELISA. E. histolytica/E. dispar antigen detection ELISA tests are inexpensive compared to the specific tests, yield objective results and do not require experienced microscopists and can therefore be recommended for screening of stools worldwide and the results can be taken for treatment that are fitting with its clinic.  相似文献   

2.
Antigen testing is now recognized as the method of choice for detection of Wuchereria bancrofti infections. Unlike tests that detect microfilariae, antigen tests can be performed with blood collected during the day or night. However, existing enzyme-linked immunosorbent assay (ELISA) tests for filarial antigenemia are difficult to perform in the field, and this has limited their use in endemic countries. In this article, Gary Weil, Patrick Lammie and Niggi Weiss review their experience with a new rapid-format filarial antigen test. They found that the ICT card test was very easy to perform and that it was comparable with ELISA for the detection of filarial antigen in sera from people with microfilaremia. The introduction now of an antigen test suitable for use in the field is especially timely, in that it may facilitate implementation of new strategies proposed by the World Health Organization for control and elimination of lymphatic filariasis.  相似文献   

3.
Entameoba histolytica, 1 of the 2 Entamoeba species with similar morphology that infect humans, causes invasive intestinal and extraintestinal diseases, whereas Entamoeba dispar is found commensally and is noninvasive. Because of their morphologic similarity, E. histolytica and E. dispar cannot be differentiated microscopically. The antigens of E. histolytica and E. dispar, however, may be detected by the ELISA method. Previous studies have found that the detection of antigens in the stool is as sensitive and specific as cultures and isoenzyme analyses. Stool samples from 272 patients with diarrhea in the province of Mersin, Turkey, were examined for the presence of Entamoeba species microscopically and for Entamoeba (E. histolytica/E. dispar) antigens using the ELISA method. An E. histolytica-specific ELISA test was used to examine 29 E. histolytica/E. disparpositive samples. Twenty-four (8.82%) of the samples tested positive for E. histolytica/E. dispar by trichrome staining, and 29 (10.6%) of the samples tested positive for E. histolytica/E. dispar by the Entamoeba screening test. Entamoeba histolytica was positive in 21 (7.72%) and E. dispar positive in 8 (2.94%) samples. The detection of true E. histolytica infection is possible with the use of E. histolytica-specific antigen ELISA tests. Thus, real cases of amoebiasis can be detected and treated, and overtreatment of the patients with E. dispar, which is the nonpathogenic species, will be prevented.  相似文献   

4.
We evaluated two commercial enzyme immunoassay kits, Binax EIA (for detection of soluble antigen of Legionella pneumophila serogroup 1) and Biotest EIA (for detection of antigens of Legionella pneumophila serogroups and other Legionella spp.) in order to introduce this test routinely for the diagnosis of Legionnaires' disease (LD) in our Laboratory. Frozen non-concentrated urine samples belonging to 45 patients with and without LD were tested. The sensitivity of Binax EIA and Biotest EIA was 47.4% and 42.1% respectively, the specificity was 95% by both tests. Biotest did not detect antigen from a patient with culture-proven infection of L. pneumophila serogroup 6. The detection of urinary antigen by both EIA tests is a useful tool for rapid diagnosis of LD, especially when samples are unavailable for culture; the sensitivity may be increased if the assay is performed on unfrozen and concentrated samples.  相似文献   

5.
BackgroundChikungunya virus (CHIKV) causes febrile illnesses and has always been misdiagnosed as other viral infections, such as dengue and Zika; thus, a laboratory test is needed. Serological tests are commonly used to diagnose CHIKV infection, but their accuracy is questionable due to varying degrees of reported sensitivities and specificities. Herein, we conducted a systematic review and meta-analysis to evaluate the diagnostic accuracy of serological tests currently available for CHIKV.Methodology and principal findingsA literature search was performed in PubMed, CINAHL Complete, and Scopus databases from the 1st December 2020 until 22nd April 2021. Studies reporting sensitivity and specificity of serological tests against CHIKV that used whole blood, serum, or plasma were included. QUADAS-2 tool was used to assess the risk of bias and applicability, while R software was used for statistical analyses.Thirty-five studies were included in this meta-analysis; 72 index test data were extracted and analysed. Rapid and ELISA-based antigen tests had a pooled sensitivity of 85.8% and 82.2%, respectively, and a pooled specificity of 96.1% and 96.0%, respectively. According to our meta-analysis, antigen detection tests serve as a good diagnostic test for acute-phase samples. The IgM detection tests had more than 90% diagnostic accuracy for ELISA-based tests, immunofluorescence assays, in-house developed tests, and samples collected after seven days of symptom onset. Conversely, low sensitivity was found for the IgM rapid test (42.3%), commercial test (78.6%), and for samples collected less than seven of symptom onset (26.2%). Although IgM antibodies start to develop on day 2 of CHIKV infection, our meta-analysis revealed that the IgM detection test is not recommended for acute-phase samples. The diagnostic performance of the IgG detection tests was more than 93% regardless of the test formats and whether the test was commercially available or developed in-house. The use of samples collected after seven days of symptom onset for the IgG detection test suggests that IgG antibodies can be detected in the convalescent-phase samples. Additionally, we evaluated commercial IgM and IgG tests for CHIKV and found that ELISA-based and IFA commercial tests manufactured by Euroimmun (Lübeck, Germany), Abcam (Cambridge, UK), and Inbios (Seattle, WA) had diagnostic accuracy of above 90%, which was similar to the manufacturers’ claim.ConclusionBased on our meta-analysis, antigen or antibody-based serological tests can be used to diagnose CHIKV reliably, depending on the time of sample collection. The antigen detection tests serve as a good diagnostic test for samples collected during the acute phase (≤7 days post symptom onset) of CHIKV infection. Likewise, IgM and IgG detection tests can be used for samples collected in the convalescent phase (>7 days post symptom onset). In correlation to the clinical presentation of the patients, the combination of the IgM and IgG tests can differentiate recent and past infections.  相似文献   

6.
Entamoeba histolytica and Entamoeba dispar are two microscopically indistinguishable amoebae living in the human colon. The former is a pathogen, whereas the latter is a nonpathogenic commensal. Using a model system of in vitro cocultures and PCR detection of the Entamoeba species, we found that the nonpathogenic species can rapidly outgrow the pathogen in xenic cultures.  相似文献   

7.
Recent advances in methods for the manufacture of inactivated poliovirus vaccines have resulted in increased vaccine immunogenicity. In conjunction with this capability it is important to have available highly sensitive and quantitative potency assays. The potential suitability of enzyme-linked immunoassay (ELISA) was evaluated using animal sera with neutralizing antibodies or neutralizing monoclonal antibodies for antigen detection in potency tests. The monoclonal antibodies developed, which bound D antigen but not C antigen, were neutralizing unless relatively weakly reactive. Those that bound C antigen only were non-neutralizing. Those that bound both C and D antigens were sometimes neutralizing. D-specific and D/C-specific neutralizing monoclonal antibodies against type-2 poliovirus protected mice on passive immunization against paralytic disease and death from the MEF strain virus. Potency measurements by ELISA using either D-specific neutralizing monoclonal antibodies or type-specific goat sera for antigen detection were sensitive and precise. Tests using C-specific monoclonal antibodies for antigen detection indicated that increased C antigen content may result in falsely elevated reactivities of animal sera with some vaccines. Monoclonal antibodies may be useful ELISA reagents for IPV potency testing.  相似文献   

8.
To optimize enzyme linked immunosorbent assays (ELISAs) for the detection of virus-specific antibodies, a range of commercially available microtitre plates was evaluated for their ability to bind virus antigen. Rinderpest virus and foot-and-mouth disease virus were investigated as target antigens. Binding capacity for antigen, binding ratios (attachment of specific antibody versus that of non-immune antibody) and the variation in the results of the tests within and between plates were measured. Binding capacity was found to be greater with rinderpest virus (RPV) antigen than with foot-and-mouth disease virus (FMDV) antigen, although higher binding ratios were obtained with FMDV antigen. Variation within and between plates was generally less with RPV antigen than with FMDV antigen. One plate could not be said to out-perform the other plates in all tests. For our purpose, that is the detection of monoclonal antibody production against a variety of virus antigens, a number of plates were found to be suitable (e.g. Dynatech M129B, Flow 77-172-05 and Nunc 4-39454). The differences in the performances of the microtitre plates with these two virus antigens highlights the need for consideration of the solid phase as part of the standardization procedures for ELISAs.  相似文献   

9.
In this communication an immunodiagnostic approach has been adopted for detection of antigen and antibody in amicrofilaeamic Mf(-) patients by countercurrent immuno electrophoresis (CCIE) and immunodiffusion (ID). Using Setaria cervi and Immune Complex (IC) antigens, out of fifteen clinical cases the number of positive patients in CCIE were twelve and ten respectively. Sixty percent of the Mf(-) cases were positive in antigen detection against both the homologous and heterologous antibody. In ID nine Mf(-) cases gave precipitin bands against S. cervi antigen while with IC antigens ten patients were positive. In similar experiments, it was found that out of fifteen Mf(-) cases nine and eleven patients were positive in antigen detection against microfilaraemic Mf(+) sera and S. cervi antibody respectively. All the Mf(+) cases were positive in both antibody and antigen detection. From the standpoint of immunodiagnosis the data were analysed by two-way analysis of variance study and a newly developed system using Binomial distribution. The sera from the control group were negative in all the immunodiagnostic tests.  相似文献   

10.
de Camargo ZP 《Mycopathologia》2008,165(4-5):289-302
This review provides the background for understanding the role of a battery of diagnostic methods in paracoccidioidomycosis (PCM). This systemic mycosis is a disease endemic in many regions of Latin America, with sporadic cases also occurring throughout the world (mycosis of importation). Although excellent laboratory methods for diagnosis are available, there are deficiencies that must be met by continued research. Understanding the uses and limitations of a battery of laboratory methods is essential to diagnose PCM. Clinicians and laboratory directors must be familiar with the uses and limitations of a battery of serologic and mycological tests to accurately diagnose of PCM. Antibody and antigen detections are valuable adjuncts to histopathology and culture. More recently, the gp43 and gp70 antigen detection assay have improved the methodology of diagnosis of this mycosis, which improves reproducibility and facilitates monitoring antigen clearance during antifungal treatment. Furthermore, detection of antigen in cerebrospinal fluid and in bronchoalveolar lavage fluid increases the sensitivity for diagnosis of PCM in central nervous system and in pulmonary infections, respectively.  相似文献   

11.
Filarial parasite, responsible for filariasis is known to remain in the host for long periods of time. A 29 kDa protein isolated fromSetaria digitata by gel electrophoresis and electroelution of detergent soluble surface antigens showed a 70% inhibition of the cell mediated immune response. On evaluation of its diagnostic application, the same protein was found to be very sensitive in detecting antibody at an antigenic protein concentration as low as 1 ng per μl. The cross reactivity of surface antigen with bancroftian filarial patient’s sera was tested by Dot-ELISA and ELISA. Both the antigen as well as antibody detection tests showed 100% positivity with all types of filariasis cases. It did not produce any positive reaction with non-endemic control sera. However, a proportion of endemic normal subjects showed positivity and this is attributed to the fact that people in endemic areas are exposed to infective mosquito bites. The biological property of inhibition and 100% positivity of filariasis cases in both antibody and antigen detection tests point towards the bifunctional nature of the surface proteins before and after release. The same may be happening under normal conditions also, perhaps at a much lower rate  相似文献   

12.
The immunoelectroosmophoresis (IEOP) test was compared with gel diffusion and complement fixation (CF) tests for sensitivity in detecting hepatitis-associated antigen (HAA) in the sera of hepatitis patients, for titration of HAA, and for detection of antibody to HAA. The IEOP test was found to be slightly more sensitive than either gel diffusion or CF tests for detection of antigen in the patients' sera. Titers of HAA demonstrated by IEOP were higher than those seen in gel diffusion tests but lower than CF titers. The gel diffusion test with an "enhancement" pattern was found to be more reliable than the other two procedures for detection of low levels of anti-HAA, due to the greater inhibitory effect of an antigen excess in the IEOP system and the possible masking of low levels of antibody by anticomplementary activity in the CF test system. Staining of immunoprecipitates in the IEOP test contributed little to the sensitivity of the test for detection of HAA.  相似文献   

13.
14.
A method of parallel serologic studies of the material for the detection of specific antigen or antibodies is proposed. This method is not inferior to the known systems of serologic tests (passive hemagglutination-antigen neutralization tests, passive hemagglutination--antibody neutralization tests, etc) in sensitivity and economy, but exceeds all of them in informative value. The method has been tested both experimentally and in the epizootic study of plague infection used as a model. A serologic tests with the use of erythrocyte diagnosticums are based on a universal principle, this method may be used for other infections.  相似文献   

15.
The in vivo incorporation of radiolabeled amino acids into antigens of Entamoeba histolytica, HM-1:IMSS, is reported. Immunoprecipitation with sera from patients with invasive amebiasis revealed a 28-kDa antigen present in whole cell lysates of E. histolytica. This antigen was of cytoplasmic origin, as indicated by cell fractionation and Triton X-114 detergent-phase separation. Immunoprecipitation, using sera from patients with invasive amebiasis and symptomless cyst passers, revealed the 28-kDa antigen as the major antigen recognized by the sera tested. Immunoprecipitation analysis using radiolabeled-released proteins instead of whole cell lysates showed a number of bands, including the 28-kDa antigen. The data suggest that the 28-kDa antigen is of cytoplasmic origin or is released from the cytoplasmic compartment.  相似文献   

16.
A new immunoassay method called specific analyte labeling and recapture assay (SALRA) to quantitatively measure protein abundance was developed, and the assay conditions were optimized. The key features of this method include labeling the antigen bound to the capture antibody, eluting the labeled antigen, and recapturing it by the same capture antibody on the detection plate. The reporter molecules on the labeled antigen provide a convenient and reliable means for signal detection. We demonstrated that the dose-response curve of SALRA was comparable to that of sandwich enzyme-linked immunosorbent assay (ELISA) and better than that of the antigen direct labeling method. In addition, multiple proteins can be measured simultaneously by SALRA. Using the SALRA method, the detection limit for most of the cytokines tested was approximately 0.01 ng/ml. Further SALRA tests on interleukin 6 (IL-6) showed the linear dose-response was 3.3 to 0.01 ng/ml, the accuracy of the test was 71 to 91%, the intraassay variation was 3.6 to 7.4%, and the interassay variation was 3.8 to 10.0%. The applications of SALRA include quantitatively measuring proteins for which there are no ELISA tools available and providing a new platform for protein microarrays.  相似文献   

17.
High-throughput multi-antigen microfluidic fluorescence immunoassays   总被引:1,自引:0,他引:1  
Here we describe the development of a high-throughput multi-antigen microfluidic fluorescence immunoassay system. A 100-chamber polydimethylsiloxane (PDMS) chip performs up to 5 tests for each of 10 samples. In this particular study system, the specificity of detection was demonstrated, and calibration curves were produced for C-reactive protein (CRP), prostate-specific antigen (PSA), ferritin, and vascular endothelial growth factor (VEGF). The measurements show sensitivity at and below clinically normal levels (with a signal-to-noise ratio >8 at as low as 10 pM antigen concentration). The chip uses 100 nL per sample for all tests. The developed system is an important step toward derivative immunoassay applications in scientific research and "point-of-care" testing in medicine.  相似文献   

18.
Natural changes that occur in blood and tissue after death may result in false positive results in antigen and antibody detection tests performed to identify markers of viral infection in potential tissue donors. Such tissue, which might otherwise be acceptable for therapeutic purposes, would not meet current standards for safe tissue banking. This is especially important in the context of insufficiency in the tissue supply. In this study, a series of blood samples collected during routine post-mortem examination was assayed using a range of commercially available kits for the detection of HBsAg, anti-HCV and anti-HIV 1 + 2 antibody/antigen. Results of tests on 104 samples collected from 97 individuals indicate that some kits result in a higher number of initial reactive samples than others. Approximately 40% of samples were reactive in one or more HBsAg assay, less than 10% in at least one anti-HIV kit and only 1 sample at low level on an anti-HCV kit. Liver or lymph node samples from individuals whose serum sample gave reactive results in antigen/antibody assays were tested for viral nucleic acid in the corresponding nucleic acid amplification test. Only one individual’s sample was confirmed to test positive for HBsAg in a confirmatory neutralisation test and by nucleic acid amplification technology, and a second individual whose serum was scored reactive for anti-HCV, but negative for HBsAg, had a liver sample which was HBV DNA positive and HCV RNA negative. The results of the study indicate that antibody/antigen assays are not as specific as NAT using state of the art DNA extraction techniques. Both types of assay complement each other and used together will help assure the safety of tissues for transplantation.  相似文献   

19.
When an endoscopy is performed, it now becomes easier to observe indirect evidence of the presence of a Helicobacter pylori infection, given the progress of new methods including magnifying narrow band imaging or confocal laser endomicroscopy. Out of the biopsy-based tests, the novel original method proposed concerned culture in a broth medium with or without antibiotics and ELISA detection of H. pylori. New stool antigen tests are still appearing with no major improvement in comparison with the monoclonal-based tests already on the market. The combination of pepsinogen detection to H. pylori serology is now more and more evaluated to detect preneoplastic lesions.  相似文献   

20.
Antigens have been prepared from the chlamydospores and blastospores of Candida albicans and their precipitin patterns were analysed by two-dimensional immunoelectrophoresis using specific antisera.The two antigens were used in routine serological tests of patients suffering from candidiasis. On double-diffusion tests for the detection of circulating antibodies of Candida albicans, the antigen from chlamydospores displays precipitin lines that differ in number and intensity from those obtained with the antigen from blastospores. The results are briefly discussed in the framework of C. albicans antigen standardization.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号