首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The determination of iron in blood plasma or serum   总被引:9,自引:0,他引:9       下载免费PDF全文
  相似文献   

2.
3.
4.
5.
6.
7.
8.
A column-switching high-performance liquid chromatographic method for the simultaneous determination of five frequently prescribed benzodiazepines: clonazepam, diazepam, flunitrazepam, midazolam and oxazepam was developed. A 50-μl plasma sample was directly injected into a BioTrap 500 MS (hydrophobic polymer) column. After a washing step with a mixture of phosphate buffer and acetonitrile, the retained benzodiazepines were back-flushed into a reversed-phase (LiChrospher Select B C8) column with a mobile phase of acetonitrile–phosphate buffer. The method showed excellent linearity from 50 to 1000 ng/ml for clonazepam, flunitrazepam and midazolam and from 50 to 5000 ng/ml for diazepam and oxazepam. The recoveries were around 98% for all the benzodiazepines studied. The relative standard deviation for between- and within-day assay was <20% for low concentrations close to the values of the limit of quantification and <4% for high concentrations. The procedure described is relatively simple and rapid because no off-line manipulation of the sample is required: the total analysis time is approximately 30 min.  相似文献   

9.
10.
A new proteinase inhibitor has recently been found in human serum or plasma which specifically inhibits cysteine proteinases such as ficin, papain, bromelain and cathepsin B. However, serum contains alpha 2-macroglobulin which also inhibits these cysteine proteinases and, consequently, interferes with the assay of the new alpha-cysteine proteinase inhibitor. Therefore, assay of the inhibitor in serum has not been established previously. In the present method, the alpha 2-macroglobulin is inactivated by preincubating the serum in methylamine solution at 55 degrees C, while the alpha-cysteine proteinase inhibitor retains its activity. The inhibitory power against cysteine proteinases is found to be due mainly to this protein in human serum. This inhibitor is also found in mammals such as cows, pigs and rats. Vitamin E deficient rats show a very high inhibitor level. Therefore, the present method will enable us to investigate the relation between diseases and the activity of the alpha-cysteine proteinase inhibitor. Also, this method is simple and inexpensive. The necessary amount of serum is only 10 microliter.  相似文献   

11.
Non-esterified fatty acids (NEFA) from C12 to C24 are assayed in human serum or plasma in a four-step procedure: extraction, volume reduction, methylation and gas chromatography. NEFA are extracted with chloroform—heptane—methanol from 50–100 μl of serum or plasma buffered with phosphate. After adding ethyl acetate the volume of the extract is reduced under partial reflux to 5–7 μl. Potassium carbonate, methyl iodide and a crown ether are added to the dry concentrate and the NEFA are selectively methylated with a yield of 100% by heating in a microrefluxer for 10 min. Gas chromatography is carried out with 1 μl of the reaction mixture on a packed column by temperature-programmed operation. Thirteen individual fatty acids are determined in sera of normal adults. The coefficients of variation for 24 determinations of a pooled serum were 2.7% for the total NEFA content and 3–10% for most of the individual NEFA.  相似文献   

12.
13.
14.
15.
16.
17.
《Biomarkers》2013,18(4):365-368
Abstract

Context: In epidemiological research, it is very important to test the stability of biomarkers as function of both storage time and temperature.

Objective: In this study, the stability of biomarkers of the iron status was tested up to 1 year of storage.

Materials and methods: The biomarkers include total iron, unsaturated iron binding capacity, ferritin, transferrin, soluble transferrin receptor, ceruloplasmin and haptoglobin.

Results: The concentrations of all biomarkers tested remain constant upon storage at ?20, ?70 and ?196?°C.

Conclusion: All biomarkers of the iron status were stable at the temperatures tested for 1 year.  相似文献   

18.
19.
An evaluation of refrigeration (7°C) to prevent falsely high plasma or serum zinc concentrations owing to elapsed time between blood collection and centrifugation was performed. At room temperature (23°C), both plasma and serum zinc concentrations increased significantly, if blood samples were stored uncentrifuged. Plasma zinc concentrations increased 6.3% at 1 h and 40.7% at 24 h, whereas serum zinc concentrations increased only 0.9% at 1 h and 12.5% at 24 h at room temperature. When blood samples were stored uncentrifuged in the refrigerator for up to 24 h, there were no significant increases in zinc concentrations in either plasma or serum. These findings suggest that plasma or serum separation should be performed immediately after blood drawing to obtain accurate zinc concentrations, and if this is not feasible, the samples should be immediately refrigerated and separation performed within eight hours.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号