首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The cervical spine functions as a complex mechanism that responds to sudden loading in a unique manner, due to intricate structural features and kinematics. The spinal load-sharing under pure compression and sagittal flexion/extension at two different impact rates were compared using a bio-fidelic finite element (FE) model of the ligamentous cervical functional spinal unit (FSU) C2–C3. This model was developed using a comprehensive and realistic geometry of spinal components and material laws that include strain rate dependency, bone fracture, and ligament failure. The range of motion, contact pressure in facet joints, failure forces in ligaments were compared to experimental findings. The model demonstrated that resistance of spinal components to impact load is dependent on loading rate and direction. For the loads applied, stress increased with loading rate in all spinal components, and was concentrated in the outer intervertebral disc (IVD), regions of ligaments to bone attachment, and in the cancellous bone of the facet joints. The highest stress in ligaments was found in capsular ligament (CL) in all cases. Intradiscal pressure (IDP) in the nucleus was affected by loading rate change. It increased under compression/flexion but decreased under extension. Contact pressure in the facet joints showed less variation under compression, but increased significantly under flexion/extension particularly under extension. Cancellous bone of the facet joints region was the only component fractured and fracture occurred under extension at both rates. The cervical ligaments were the primary load-bearing component followed by the IVD, endplates and cancellous bone; however, the latter was the most vulnerable to extension as it fractured at low energy impact.  相似文献   

2.
Understanding spinal kinematics is essential for distinguishing between pathological conditions of spine disorders, which ultimately lead to low back pain. It is of high importance to understand how changes in mechanical properties affect the response of the lumbar spine, specifically in an effort to differentiate those associated with disc degeneration from ligamentous changes, allowing for more precise treatment strategies. To do this, the goals of this study were twofold: (1) develop and validate a finite element (FE) model of the lumbar spine and (2) systematically alter the properties of the intervertebral disc and ligaments to define respective roles in functional mechanics. A three-dimensional non-linear FE model of the lumbar spine (L3-sacrum) was developed and validated for pure moment bending. Disc degeneration and sequential ligament failure were modelled. Intersegmental range of motion (ROM) and bending stiffness were measured. The prediction of the FE model to moment loading in all three planes of bending showed very good agreement, where global and intersegmental ROM and bending stiffness of the model fell within one standard deviation of the in vitro results. Degeneration decreased ROM for all directions. Stiffness increased for all directions except axial rotation, where it initially increased then decreased for moderate and severe degeneration, respectively. Incremental ligament failure produced increased ROM and decreased stiffness. This effect was much more pronounced for all directions except lateral bending, which is minimally impacted by ligaments. These results indicate that lateral bending may be more apt to detect the subtle changes associated with degeneration, without being masked by associated changes of surrounding stabilizing structures.  相似文献   

3.
In a finite element (FE) analysis of the lumbar spine, different preload application methods that are used in biomechanical studies may yield diverging results. To investigate how the biomechanical behaviour of a spinal implant is affected by the method of applying the preload, hybrid-controlled FE analysis was used to evaluate the biomechanical behaviour of the lumbar spine under different preload application methods. The FE models of anterior lumbar interbody fusion (ALIF) and artificial disc replacement (ADR) were tested under three different loading conditions: a 150 N pressure preload (PP) and 150 and 400 N follower loads (FLs). This study analysed the resulting range of motion (ROM), facet contact force (FCF), inlay contact pressure (ICP) and stress distribution of adjacent discs. The FE results indicated that the ROM of both surgical constructs was related to the preload application method and magnitude; differences in the ROM were within 7% for the ALIF model and 32% for the ADR model. Following the application of the FL and after increasing the FL magnitude, the FCF of the ADR model gradually increased, reaching 45% at the implanted level in torsion. The maximum ICP gradually decreased by 34.1% in torsion and 28.4% in lateral bending. This study concluded that the preload magnitude and application method affect the biomechanical behaviour of the lumbar spine. For the ADR, remarkable alteration was observed while increasing the FL magnitude, particularly in the ROM, FCF and ICP. However, for the ALIF, PP and FL methods had no remarkable alteration in terms of ROM and adjacent disc stress.  相似文献   

4.
Cervical spine finite element models reported in biomechanical literature usually represent a static morphology. Not considering morphology as a model parameter limits the predictive capabilities for applications in personalized medicine, a growing trend in modern clinical practice. The objective of the study was to investigate the influence of variations in spinal morphology on the flexion-extension responses, utilizing mesh-morphing-based parametrization and metamodel-based sensitivity analysis. A C5-C6 segment was used as the baseline model. Variations of intervertebral disc height, facet joint slope, facet joint articular processes height, vertebral body anterior-posterior depth, and segment size were parametrized. In addition, material property variations of ligaments were considered for sensitivity analysis. The influence of these variations on vertebral rotation and forces in the ligaments were analyzed. The disc height, segmental size, and body depth were found to be the most influential (in the cited order) morphology variations; while among the ligament material property variations, capsular ligament and ligamentum flavum influenced vertebral rotation the most. Changes in disc height influenced forces in the posterior ligaments, indicating that changes in the anterior load-bearing column of the spine could have consequences on the posterior column. A method to identify influential morphology variations is presented in this work, which will help automation efforts in modeling to focus on variations that matter. This study underscores the importance of incorporating influential morphology parameters, easily obtained through computed tomography/magnetic resonance images, to better predict subject-specific biomechanical responses for applications in personalized medicine.  相似文献   

5.
Axial compression on the spine could reach large values especially in lifting tasks which also involve large rotations. Experimental and numerical investigations on the spinal multi motion segments in presence of physiological compression loads cannot adequately be carried out due to the structural instability and artefact loads. To circumvent these problems, a novel wrapping cable element is used in a nonlinear finite element model of the lumbosacral spine (L1-S1) to investigate the role of moderate to large compression loads on the lumbar stiffness in flexion and axial moments/rotations. The compression loads up to 2,700 N was applied with no instability or artefact loads. The lumbar stiffness substantially increased under compression force, flexion moment, and axial torque when applied alone. The presence of compression preloads significantly stiffened the load-displacement response under flexion and axial moments/rotations. This stiffening effect was much more pronounced under larger preloads and smaller moments/rotations. Compression preloads also increased intradiscal pressure, facet contact forces, and maximum disc fibre strain at different levels. Forces in posterior ligaments were, however, diminished with compression preload. The significant increase in spinal stiffness, hence, should be considered in biomechanical studies for accurate investigation of the load partitioning, system stability, and fixation systems/disc prostheses.  相似文献   

6.
Many investigators have performed studies on specific defect situations or determined the contribution on isolated structures. Investigating the contribution of functional structures requires obtaining the kinematic response directly on spinal segments. The purpose of this study was to quantify the function of anatomical components on lumbar segments for different loading magnitudes. Eight spinal segments (L4-5) with a median age of 52 years (ranging from 38 to 59 years) and a low degree of disc degeneration were utilized for the in vitro testing. Specimens were mounted in a custom-built spine tester and loaded with pure moments (1-10 N m) to move within three anatomical planes at a loading rate of 1.0 degrees /s. Anatomy was successively reduced by: ligaments, facet capsules, joints and nucleus. Data were evaluated for range of motion, neutral zone and lordosis angle. Transection of posterior ligaments predominantly increased specimen flexion for all bending moments applied. Supraspinous ligament also indicated to resist in extension slightly, whereas the facet capsules did not. Facet joints contributed to axial rotation, but not in lateral bending. The anterior longitudinal ligament was found to slightly resist in axial rotation, but strongly in extension. Nucleotomy caused largest increase of all movements. The unloaded posture of the specimens changed after ligament dissection, indicating ligament pretension. The region of lumbar spine is interesting for finite element (FE) simulation due to the high evidence of disc degeneration and injuries. This study may help to understand the function of specific anatomical structures and assists in FE model calibration. We suggest to start a calibration procedure for such models with the smallest functional structure (annulus) and to cumulatively add further structures.  相似文献   

7.
This paper presents three-dimensional static modeling of the human lumbar spine to be used in the formation of anatomically-correct movement patterns for a fully cable-actuated robotic lumbar spine which can mimic in vivo human lumbar spine movements to provide better hands-on training for medical students. The mathematical model incorporates five lumbar vertebrae between the first lumbar vertebra and the sacrum, with dimensions of an average adult human spine. The vertebrae are connected to each other by elastic elements, torsional springs and a spherical joint located at the inferoposterior corner in the mid-sagittal plane of the vertebral body. Elastic elements represent the ligaments that surround the facet joints and the torsional springs represent the collective effect of intervertebral disc which plays a major role in balancing torsional load during upper body motion and the remaining ligaments that support the spinal column. The elastic elements and torsional springs are considered to be nonlinear. The nonlinear stiffness constants for six motion types were solved using a multiobjective optimization technique. The quantitative comparison between the angles of rotations predicted by the proposed model and in the experimental data confirmed that the model yields angles of rotation close to the experimental data. The main contribution is that the new model can be used for all motions while the experimental data was only obtained at discrete measurement points.  相似文献   

8.
Numerical modelling can provide a thorough understanding of the mechanical influence on the spinal tissues and may offer explanations to mechanically linked pathologies. Such objective might be achieved only if the models are carefully validated. Sensitivity study must be performed in order to evaluate the influence of the approximations inherent to modelling. In this study, a new geometrically accurate L3-L5 lumbar spine bi-segmental finite-element model was acquired by modifying a previously existing model. The effect of changes in bone geometry, ligament fibres distribution, nucleus position and disc height was investigated in flexion and extension by comparison of the results obtained from the model before and after the geometrical update. Additional calculations were performed in axial rotation and lateral bending in order to compare the computed ranges of motion (ROM) with experimental results. It was found that the geometrical parameters affected the stress distribution and strain energy in the zygapophysial joints, the ligaments, and the intervertebral disc, changing qualitatively and quantitatively their relative role in resisting the imposed loads. The predicted ROM were generally in good agreement with the experimental results, independently of the geometrical changes. Hence, although the model update affected its internal biomechanics, no conclusions could be drawn from the experimental data about the validation of a particular geometry. Hence the validation of the lumbar spine model should be based on the relative role of its structural components and not only on its global mobility.  相似文献   

9.
The human spinal segment is an inherently complex structure, a combination of flexible and semi-rigid articulating elements stabilised by seven principal ligaments. An understanding of how mechanical loading is shared among these passive elements of the segment is required to estimate tissue failure stresses. A 3D rigid body model of the complete lumbar spine has been developed to facilitate the prediction of load sharing across the passive elements. In contrast to previous multibody models, this model includes a non-linear, six degrees of freedom intervertebral disc, facet bony articulations and all spinal ligaments. Predictions of segmental kinematics and facet joint forces, in response to pure moment loading (flexion-extension), were compared to published in vitro data. On inclusion of detailed representation of the disc and facets, the multibody model fully captures the non-linear flexibility response of the spinal segment, i.e. coupled motions and a mobile instantaneous centre of rotation. Predicted facet joint forces corresponded well with reported values. For the loading case considered, the model predicted that the ligaments are the main stabilising elements within the physiological motion range; however, the disc resists a greater proportion of the applied load as the spine is fully flexed. In extension, the facets and capsular ligaments provide the principal resistance. Overall patterns of load distribution to the spinal ligaments are in agreement with previous predictions; however, the current model highlights the important role of the intraspinous ligament in flexion and the potentially high risk of failure. Several important refinements to the multibody modelling of the passive elements of the spine have been described, and such an enhanced passive model can be easily integrated into a full musculoskeletal model for the prediction of spinal loading for a variety of daily activities.  相似文献   

10.
The human spinal segment is an inherently complex structure, a combination of flexible and semi-rigid articulating elements stabilised by seven principal ligaments. An understanding of how mechanical loading is shared among these passive elements of the segment is required to estimate tissue failure stresses. A 3D rigid body model of the complete lumbar spine has been developed to facilitate the prediction of load sharing across the passive elements. In contrast to previous multibody models, this model includes a non-linear, six degrees of freedom intervertebral disc, facet bony articulations and all spinal ligaments. Predictions of segmental kinematics and facet joint forces, in response to pure moment loading (flexion–extension), were compared to published in vitro data. On inclusion of detailed representation of the disc and facets, the multibody model fully captures the non-linear flexibility response of the spinal segment, i.e. coupled motions and a mobile instantaneous centre of rotation. Predicted facet joint forces corresponded well with reported values. For the loading case considered, the model predicted that the ligaments are the main stabilising elements within the physiological motion range; however, the disc resists a greater proportion of the applied load as the spine is fully flexed. In extension, the facets and capsular ligaments provide the principal resistance. Overall patterns of load distribution to the spinal ligaments are in agreement with previous predictions; however, the current model highlights the important role of the intraspinous ligament in flexion and the potentially high risk of failure. Several important refinements to the multibody modelling of the passive elements of the spine have been described, and such an enhanced passive model can be easily integrated into a full musculoskeletal model for the prediction of spinal loading for a variety of daily activities.  相似文献   

11.
Data has been published that quantifies the nonlinear, anisotropic material behaviour and pre-strain behaviour of the anterior longitudinal, supraspinous (SSL), and interspinous ligaments of the human lumbar spine. Additionally, data has been published on localized material properties of the SSL. These results have been incrementally incorporated into a previously validated finite element model of the human lumbar spine. Results suggest that the effects of increased ligament model fidelity on bone strain energy were moderate and the effects on disc pressure were slight, and do not justify a change in modelling strategy for most clinical applications. There were significant effects on the ligament stresses of the ligaments that were directly modified, suggesting that these phenomena should be included in FE models where ligament stresses are the desired metric.  相似文献   

12.
Surgical treatments for lower back pain can be distributed into two main groups: fusion (arthrodesis) and disc replacement (arthroplasty). The objective of this study was to compare, under severe loading conditions, the biomechanics of the lumbar spine treated either by fusion or total disc replacement (TDR). A three-dimensional model of a two-level ligamentous lumbar segment was created and simulated through static analyses with the finite-element method (FEM) software ABAQUS. The model was validated by comparing mobility, pressure on the facets, force in the ligaments, maximum stresses, disc bulge, and endplate deflection with measured data given in the literature. The FEM analysis predicted that the mobility of the model after arthrodesis on the upper level was reduced in all rotational degrees of freedom by an average of approximately 44%, relative to healthy normal discs. Conversely, the mobility of the model after TDR on the upper level was increased in all rotational degrees of freedom by an average of approximately 52%. The level implanted with the artificial disc showed excessive ligament tensions (greater than 500 N), high facet pressures (greater than 3 MPa), and a high risk of instability. The mobility and the stresses in the level adjacent to the arthroplasty were also increased. In conclusion, the model for an implanted movable artificial disc illustrated complications common to spinal arthroplasty and showed greater risk of instability and further degeneration than predicted for the fused model. This modeling technique provides an accurate means for assessing potential biomechanical risks and can be used to improve the design of future artificial intervertebral discs.  相似文献   

13.
The two main load bearing tissues of the intervertebral disc are the nucleus pulposus and the annulus fibrosus. Both tissues are composed of the same basic components, but differ in their organization and relative amounts. With degeneration, the clear distinction between the two tissues disappears. The changes in biochemical content lead to changes in mechanical behaviour of the intervertebral disc. The aim of the current study was to investigate if well-documented moderate degeneration at the biochemical and fibre structure level leads to instability of the lumbar spine. By taking into account biochemical and ultrastructural changes to the extracellular matrix of degenerating discs, a set of constitutive material parameters were determined that described the individual tissue behaviour. These tissue biomechanical models were then used to simulate dynamic behaviour of the degenerated spinal motion segment, which showed instability in axial rotation, while a stabilizing effect in the other two principle bending directions. When a shear load was applied to the degenerated spinal motion segment, no sign of instability was found. This study found that reported changes to the nucleus pulposus and annulus fibrosus matrix during moderate degeneration lead to a more stable spinal motion segment and that such biomechanical considerations should be incorporated into the general pathophysiological understanding of disc degeneration and how its progress could affect low back pain and its treatments thereof.  相似文献   

14.
Previous in-vivo studies suggest that the ratio of total lumbar rotation over pelvic rotation (lumbo-pelvic rhythm) during trunk sagittal movement is essential to evaluate spinal loads and discriminate between low back pain and asymptomatic population. Similarly, there is also evidence that the lumbo-pelvic rhythm is key for evaluation of realistic muscle and joint reaction forces and moments predicted by various computational musculoskeletal models. This study investigated the effects of three lumbo-pelvic rhythms defined based on in-vivo measurements on the spinal response during moderate forward flexion (60°) using a combined approach of musculoskeletal modeling of the upper body and finite element model of the lumbosacral spine. The muscle forces and joint loads predicted by the musculoskeletal model, together with the gravitational forces, were applied to the finite element model to compute the disc force and moment, intradiscal pressure, annular fibers strain, and load-sharing. The results revealed that a rhythm with high pelvic rotation and low lumbar flexion involves more global muscles and increases the role of the disc in resisting spinal loads, while its counterpart, with low pelvic rotation, recruits more local muscles and engages the ligaments to lower the disc loads. On the other hand, a normal rhythm that has balanced pelvic and lumbar rotations yields almost equal disc and ligament load-sharing and results in more balanced synergy between global and local muscles. The lumbo-pelvic rhythm has less effect on the intradiscal pressure and annular fibers strain. This work demonstrated that the spinal response during forward flexion is highly dependent on the lumbo-pelvic rhythm. It is therefore, essential to adapt this parameter instead of using the default values in musculoskeletal models for accurate prediction of muscle forces and joint reaction forces and moments. The findings provided by this work are expected to improve knowledge of spinal response during forward flexion, and are clinically relevant towards low back pain treatment and disc injury prevention.  相似文献   

15.
Inappropriate lordotic angle of lumbar fusion cage could be associated with cage damage or subsidence. The biomechanical influence of cage lordotic angle on lumbar spine has not been fully investigated. Four surgical finite element models were constructed by inserting cages with various lordotic angles at L3-L4 disc space. The four motion modes were simulated. The range of motion (ROM) decreased with increased lordotic angle of cage in flexion, extension, and rotation, whereas it was not substantially changed in bending. The maximum stress in cage decreased with increased lordotic angle of cage in all motion modes. The maximum stress in endplate at surgical level increased with increased lordotic angle of cage in flexion and rotation, whereas it was not substantially changed in extension and bending. The facet joint force (FJF) was much smaller than that for the intact conditions in extension, bending, and rotation, while it was not substantially changed in flexion. In conclusion, the ROM, stresses in the cage and endplate at surgical level are sensitive to the lordotic angle of cage. The increased cage lordotic angle may provide better stability and reduce the risk of cage damage, whereas it may increase the risk of subsidence in flexion and rotation.  相似文献   

16.
Purpose: Deeper insights into the mechanical behavior of lumbar disc prostheses are required. Prior studies on the biomechanical performance of artificial discs were mostly performed with finite element analyses, but this has never been analyzed with altering articulate curvature. This study aimed to ascertain the influence of the geometry of a ball-and-socket disc prosthesis for the lumbar spine. Materials and Methods: Three-dimensional finite element model of human L4-L5 was reconstructed. Convex, concave, and elliptic artificial disc models were also established with Computer-Aided-Design software. Simulations included: (1) three articulate types of polyethylene (PE) insert were implanted inferiorly and (2) concave and convex PE inserts were implanted on the superior or inferior sides in flexion/extension, lateral bending, and axial rotation in the lumbar spine. Shear stresses and von Mises stresses on PE insert were assessed for their loading distributions. Results: High shear stresses of all articulate types occurred in flexion, and convex PE insert performed the maximum stress of 23.81 MPa. Under all conditions, stresses on concave PE inserts were distributed more evenly and lower than those on the convex type. Elliptic geometry enabled confining the rotation of the motion unit. The shear force on the convex PE insert on the inferior side could induce transverse crack because the shear stress exceeded yielding shear stress. Conclusions: The concave PE insert on the inferior side not only decreased loading concentration but had relatively low stress. Such a design may be applicable for artificial discs.  相似文献   

17.
The influence of the different lumbar spinal ligaments on intersegmental rotation is not fully understood. In order to explore this effect, a finite element model of the functional spinal unit L3/L4 was loaded with pure moments in the three main anatomic planes. The two extremes--minimum and maximum--ligament stiffness values reported in the literature were applied. After virtual transection of each of the spinal ligaments in turn, the intersegmental rotation and forces in the remaining ligaments were calculated. On flexion, the highest force was found for the posterior longitudinal ligament; on extension and lateral bending for the anterior longitudinal ligament; and on axial rotation for the facet capsular ligament. The strongest influence on intersegmental rotation is exerted by the interspinous ligament on flexion, by the anterior longitudinal ligament on extension and lateral bending, and by the facet capsular ligaments on axial rotation. Ligament stiffness has a strong influence on intersegmental rotation and forces in the ligaments, so that finite element models of spinal segments must be validated by experimental data. This study should help to elucidate the role of the various ligaments.  相似文献   

18.
Geometric and mechanical properties of human cervical spine ligaments   总被引:12,自引:0,他引:12  
This study characterized the geometry and mechanical properties of the cervical ligaments from C2-T1 levels. The lengths and cross-sectional areas of the anterior longitudinal ligament, posterior longitudinal ligament, joint capsules, ligamentum flavum, and interspinous ligament were determined from eight human cadavers using cryomicrotomy images. The geometry was defined based on spinal anatomy and its potential use in complex mathematical models. The biomechanical force-deflection, stiffness, energy, stress, and strain data were obtained from 25 cadavers using in situ axial tensile tests. Data were grouped into middle (C2-C5) and lower (C5-T1) cervical levels. Both the geometric length and area of cross section, and the biomechanical properties including the stiffness, stress, strain, energy, and Young's modulus, were presented for each of the five ligaments. In both groups, joint capsules and ligamentum flavum exhibited the highest cross-sectional area (p < 0.005), while the longitudinal ligaments had the highest length measurements. Although not reaching statistical significance, for all ligaments, cross-sectional areas were higher in the C5-T1 than in the C2-C5 group; and lengths were higher in the C2-C5 than in the C5-T1 group with the exception of the flavum (Table 1 in the main text). Force-deflection characteristics (plots) are provided for all ligaments in both groups. Failure strains were higher for the ligaments of the posterior (interspinous ligament, joint capsules, and ligamentum flavum) than the anterior complex (anterior and posterior longitudinal ligaments) in both groups. In contrast, the failure stress and Young's modulus were higher for the anterior and posterior longitudinal ligaments compared to the ligaments of the posterior complex in the two groups. However, similar tendencies in the structural responses (stiffness, energy) were not found in both groups. Researchers attempting to incorporate these data into stress-analysis models can choose the specific parameter(s) based on the complexity of the model used to study the biomechanical behavior of the human cervical spine.  相似文献   

19.
The biomechanical properties of the ligamentous cadaver spine have been previously examined using a variety of experimental testing protocols. Ongoing technical challenges in the biomechanical testing of the spine include the application of physiologic compressive loads and the application of dynamic bending moments while allowing unconstrained three-dimensional motion. The purpose of this study was to report the development of a novel pendulum apparatus that addressed these challenges and to determine the effects of various axial compressive loads on the dynamic biomechanical properties of the lumbar functional spinal unit (FSU). Lumbar FSUs were tested in flexion and extension under five axial compressive loads chosen to represent physiologic loading conditions. After an initial rotation, the FSUs behaved as a dynamic, underdamped vibrating elastic system. Bending stiffness and coefficient of damping increased significantly as the compressive pendulum load increased. The apparatus described herein is a relatively simple approach to determining the dynamic bending properties of the FSU, and potentially disc arthroplasty devices. It is capable of applying physiologic compressive loads at dynamic rates without constraining the kinematics of the joints, crucial requirements for testing FSUs in vitro.  相似文献   

20.
Effect of an interspinous implant on loads in the lumbar spine.   总被引:3,自引:0,他引:3  
Interspinous process implants are increasingly used to treat canal stenoses. Little information exists about the effects of implant height and stiffness on the biomechanical behavior of the lumbar spine. Therefore, a three-dimensional nonlinear finite element model of the osseoligamentous lumbar spine (L1 to L5) was created with a slightly degenerated disc at L3/L4. An interspinous implant was inserted at that segment. Implants with different heights and stiffnesses were studied. The model was loaded with the upper body weight and muscle forces to simulate walking and 25 degrees extension. Implant forces are influenced strongly by the height and negligibly by the elastic modulus of the implant. Intersegmental rotation at implant level is markedly reduced, while intradiscal pressure is slightly increased. Implant size and stiffness have only a minor effect on intradiscal pressure. The maximum von Mises stress in the vertebral arch is strongly increased by the implant.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号