共查询到20条相似文献,搜索用时 15 毫秒
1.
Christoph Engelhardt Valérie Malfroy Camine David Ingram Philippe Müllhaupt Alain Farron Dominique Pioletti 《Computer methods in biomechanics and biomedical engineering》2013,16(12):1272-1279
The estimation of muscle forces in musculoskeletal shoulder models is still controversial. Two different methods are widely used to solve the indeterminacy of the system: electromyography (EMG)-based methods and stress-based methods. The goal of this work was to evaluate the influence of these two methods on the prediction of muscle forces, glenohumeral load and joint stability after total shoulder arthroplasty. An EMG-based and a stress-based method were implemented into the same musculoskeletal shoulder model. The model replicated the glenohumeral joint after total shoulder arthroplasty. It contained the scapula, the humerus, the joint prosthesis, the rotator cuff muscles supraspinatus, subscapularis and infraspinatus and the middle, anterior and posterior deltoid muscles. A movement of abduction was simulated in the plane of the scapula. The EMG-based method replicated muscular activity of experimentally measured EMG. The stress-based method minimised a cost function based on muscle stresses. We compared muscle forces, joint reaction force, articular contact pressure and translation of the humeral head. The stress-based method predicted a lower force of the rotator cuff muscles. This was partly counter-balanced by a higher force of the middle part of the deltoid muscle. As a consequence, the stress-based method predicted a lower joint load (16% reduced) and a higher superior–inferior translation of the humeral head (increased by 1.2 mm). The EMG-based method has the advantage of replicating the observed cocontraction of stabilising muscles of the rotator cuff. This method is, however, limited to available EMG measurements. The stress-based method has thus an advantage of flexibility, but may overestimate glenohumeral subluxation. 相似文献
2.
Y. Fang M. O. Lagravère P. W. Major R. R. Toogood 《Computer methods in biomechanics and biomedical engineering》2013,16(2):137-149
Objective: Develop a finite element (FE) model of a skull to perform biomechanical studies of maxillary expansion using bone anchors (BA). Materials and methods: A skull model was developed and assigned material properties based on Hounsfield unit (HU) values of cone-beam computerized tomography (CBCT) images. A 3 mm diameter cylindrical BA was modelled and inserted in the palatal bone. A 4 mm transverse displacement was applied on the anchor. An evaluation on the effect on local stresses of BA implantation inclination angle was performed. Results: Proper displacement results and strain–stress trends for the expansion process were present. Stress distribution patterns were similar as reported in the literature. No significant difference between BA inclination angles was found. Conclusion: This work leads to a better understanding and prediction of craniofacial and maxillary bone remodelling during ME with BA treatments and is a first step towards the development of patient specific treatments. 相似文献
3.
Chentian Li Rongwei Tan Yuanjun Guo 《Computer methods in biomechanics and biomedical engineering》2018,21(1):83-90
Background: There is lack of further observations on the microstructure and material property of callus during bone defect healing and the relationships between callus properties and the mechanical strength. Methods: Femur bone defect model was created in rabbits and harvested CT data to reconstruct finite element models at 1 and 2 months. Three types of assumed finite element models were compared to study the callus properties, which assumed the material elastic property as heterogeneous (R-model), homogenous (H-model) or did not change from 1 to 2 months (U-model). Results: The apparent elastic moduli increased at 2 months (from 355.58 ± 132.67 to 1139.30 ± 967.43 MPa) in R-models. But there was no significant difference in apparent elastic moduli between R-models (355.58 ± 132.67 and 1139.30 ± 967.43 MPa) and H-models (344.79 ± 138.73 and 1001.52 ± 692.12 MPa) in 1 and 2 months. A significant difference of apparent elastic moduli was found between the R-model (1139.30 ± 967.43 MPa) and U-model group (207.15 ± 64.60 MPa) in 2 months. Conclusions: This study showed that the callus structure stability remodeled overtime to achieve a more effective structure, while the material quality of callus tissue is a very important factor for callus strength. At the meantime, this study showed an evidence that the material heterogeneity maybe not as important as it is in bone fracture model. 相似文献
4.
Masakazu Hasegawa Teruko Takano-Yamamoto 《Computer methods in biomechanics and biomedical engineering》2016,19(5):474-483
Orthodontic tooth movement (OTM) is an adaptive biomechanical response of dentoalveolar components to orthodontic forces, in which remodeling of the alveolar bone occurs in response to changes in the surrounding mechanical environment. In this study, we developed a framework for OTM simulation by combining an image-based voxel finite element method, with a surface-tracking level set method using three-dimensional computer models. For a case study to demonstrate its capability of expressing clinical tooth movement, we observed displacement and rotation of the tooth under three types of force conditions. The simulation results demonstrate that the proposed simulation method has the potential to predict clinical OTM. 相似文献
5.
Zhuo Yang Jaclyn Hayes Sundar Krishnamurty 《Computer methods in biomechanics and biomedical engineering》2016,19(16):1772-1784
Objectives: The purpose of this study is to develop a validated 3D finite element model of the pelvic floor system which can offer insights into the mechanics of anterior vaginal wall prolapse and have the ability to assess biomedical device treatment methods. The finite element results should accurately mimic the clinical findings of prolapse due to intra-abdominal pressure (IAP) and soft tissues impairment conditions. Methods: A 3D model of pelvic system was created in Creo Parametric 2.0 based on MRI Images, which included uterus, cervix, vagina, cardinal ligaments, uterosacral ligaments, and a simplified levator plate and rectum. The geometrical model was imported into ANSYS Workbench 14.5. Mechanical properties of soft tissues were based on experimental data of tensile test results from current literature. Studies were conducted for IAP loadings on the vaginal wall and uterus, increasing from lowest to extreme values. Results: Anterior vaginal wall collapse occurred at an IAP value corresponding to maximal valsalva and showed similar collapsed shape as clinical findings. Prolapse conditions exhibited high sensitivity to vaginal wall stiffness, whereas healthy tissues was found to support the vagina against prolapse. Ligament impairment was found to have only a secondary effect on prolapse. 相似文献
6.
Representation of realistic muscle geometries is needed for systematic biomechanical simulation of musculoskeletal systems. Most of the previous musculoskeletal models are based on multibody dynamics simulation with muscles simplified as one-dimensional (1D) line-segments without accounting for the large muscle attachment areas, spatial fibre alignment within muscles and contact and wrapping between muscles and surrounding tissues. In previous musculoskeletal models with three-dimensional (3D) muscles, contractions of muscles were among the inputs rather than calculated, which hampers the predictive capability of these models. To address these issues, a finite element musculoskeletal model with the ability to predict contractions of 3D muscles was developed. Muscles with realistic 3D geometry, spatial muscle fibre alignment and muscle-muscle and muscle-bone interactions were accounted for. Active contractile stresses of the 3D muscles were determined through an efficient optimization approach based on the measured kinematics of the lower extremity and ground force during gait. This model also provided stresses and strains of muscles and contact mechanics of the muscle-muscle and muscle-bone interactions. The total contact force of the knee predicted by the model corresponded well to the in vivo measurement. Contact and wrapping between muscles and surrounding tissues were evident, demonstrating the need to consider 3D contact models of muscles. This modelling framework serves as the methodological basis for developing musculoskeletal modelling systems in finite element method incorporating 3D deformable contact models of muscles, joints, ligaments and bones. 相似文献
7.
Rui Liang Weihua Guo Xiangchen Qiao Hailin Wen Mei Yu Wei Tang 《Computer methods in biomechanics and biomedical engineering》2013,16(12):1340-1348
Finite element analysis plays an important role in dental implant design. The objective of this study was to show the effect of the overall geometry of dental implants on their biomechanics after implantation. In this study, 12 dental implants, with the same length, diameter and screw design, were simulated from different implant systems. Numerical model of right mandibular incisor bone segment was generated from CT data. The von-Mises stress distributions and the total deformation distributions under vertical/lateral load were compared for each implant by scores ranking method. The implants with cylindrical shapes had highest scores. Results indicated that cylindrical shape represented better geometry over taper implant. This study is helpful in choosing the optimal dental implant for clinical application and also contributes to individual implant design. Our study could also provide reference for choice and modification of dental implant in any other insertion sites and bone qualities. 相似文献
8.
Carmen González-Lluch Joaquín L. Sancho-Bru Pablo-Jesús Rodríguez-Cervantes 《Computer methods in biomechanics and biomedical engineering》2014,17(10):1108-1118
Many studies have investigated the effect of different parameters of the endodontically restored tooth on its final strength, using in vitro tests and model simulations. However, the differences in the experimental set-up or modelling conditions and the limited number of parameters studied in each case prevent us from obtaining clear conclusions about the relative importance of each parameter. In this study, a validated 3D biomechanical model of the restored tooth was used for an exhaustive sensitivity analysis. The individual influence of 20 different parameters on the mechanical performance of an endodontic restoration with prefabricated posts was studied. The results bring up the remarkable importance of the loading angle on the final restoration strength. Flexural loads are more critical than compressive or tensile loads. Young's modulus of the post and its length and diameter are the most influential parameters for strength, whereas other parameters such as ferrule geometry or core and crown characteristics are less significant. 相似文献
9.
Finite element (FE) modelling has been proposed as a tool for estimating fracture risk and patient-specific FE models are commonly based on computed tomography (CT). Here, we present a novel method to automatically create personalised 3D models from standard 2D hip radiographs. A set of geometrical parameters of the femur were determined from seven a–p hip radiographs and compared to the 3D femoral shape obtained from CT as training material; the error in reconstructing the 3D model from the 2D radiographs was assessed. Using the geometry parameters as the input, the 3D shape of another 21 femora was built and meshed, separating a cortical and trabecular compartment. The material properties were derived from the homogeneity index assessed by texture analysis of the radiographs, with focus on the principal tensile and compressive trabecular systems. The ability of these FE models to predict failure load as determined by experimental biomechanical testing was evaluated and compared to the predictive ability of DXA. The average reconstruction error of the 3D models was 1.77 mm (±1.17 mm), with the error being smallest in the femoral head and neck, and greatest in the trochanter. The correlation of the FE predicted failure load with the experimental failure load was r2=64% for the reconstruction FE model, which was significantly better (p<0.05) than that for DXA (r2=24%). This novel method for automatically constructing a patient-specific 3D finite element model from standard 2D radiographs shows encouraging results in estimating patient-specific failure loads. 相似文献
10.
M. Fernandez M. House S. Jambawalikar N. Zork J. Vink R. Wapner 《Computer methods in biomechanics and biomedical engineering》2016,19(4):404-417
Preterm birth is a strong contributor to perinatal mortality, and preterm infants that survive are at risk for long-term morbidities. During most of pregnancy, appropriate mechanical function of the cervix is required to maintain the developing fetus in utero. Premature cervical softening and subsequent cervical shortening are hypothesized to cause preterm birth. Presently, there is a lack of understanding of the structural and material factors that influence the mechanical function of the cervix during pregnancy. In this study we build finite element models of the pregnant uterus, cervix, and fetal membrane based on magnetic resonance imagining data in order to examine the mechanical function of the cervix under the physiologic loading conditions of pregnancy. We calculate the mechanical loading state of the cervix for two pregnant patients: 22 weeks gestational age with a normal cervical length and 28 weeks with a short cervix. We investigate the influence of (1) anatomical geometry, (2) cervical material properties, and (3) fetal membrane material properties, including its adhesion properties, on the mechanical loading state of the cervix under physiologically relevant intrauterine pressures. Our study demonstrates that membrane–uterus interaction, cervical material modeling, and membrane mechanical properties are factors that must be deliberately and carefully handled in order to construct a high quality mechanical simulation of pregnancy. 相似文献
11.
A good knowledge of midfoot biomechanics is important in understanding the biomechanics of the entire foot,but it has never been investigated thoroughly in the literature.This study carried out in vitro experiments and finite element analysis to investigate the midfoot biomechanics.A foot-ankle finite element model simulating the mid-stance phase of the normal gait was developed and the model validated in in vitro experimental tests.Experiments used seven in vitro samples of fresh human cadavers.The simulation found that the first principal stress peaks of all midfoot bones occurred at the navicular bone and that the tensile force of the spring ligament was greater than that of any other ligament.The experiments showed that the longitudinal strain acting on the medial cuneiform bone was-26.2±10.8μ-strain,and the navicular strain was-240.0±169.1μ-strain along the longitudinal direction and 65.1±25.8μ-strain along the transverse direction.The anatomical position and the spring ligament both result in higher shear stress in the navicular bone.The load from the ankle joint to five branches of the forefoot is redistributed among the cuneiforms and cuboid bones.Further studies on the mechanism of loading redistribution will be helpful in understanding the biomechanics of the entire foot. 相似文献
12.
13.
Annamaria Guiotto Zimi Sawacha Gabriella Guarneri Angelo Avogaro Claudio Cobelli 《Journal of biomechanics》2014
Diabetic foot is an invalidating complication of diabetes that can lead to foot ulcers. Three-dimensional (3D) finite element analysis (FEA) allows characterizing the loads developed in the different anatomical structures of the foot in dynamic conditions. The aim of this study was to develop a subject specific 3D foot FE model (FEM) of a diabetic neuropathic (DNS) and a healthy (HS) subject, whose subject specificity can be found in term of foot geometry and boundary conditions. Kinematics, kinetics and plantar pressure (PP) data were extracted from the gait analysis trials of the two subjects with this purpose. The FEM were developed segmenting bones, cartilage and skin from MRI and drawing a horizontal plate as ground support. Materials properties were adopted from previous literature. FE simulations were run with the kinematics and kinetics data of four different phases of the stance phase of gait (heel strike, loading response, midstance and push off). FEMs were then driven by group gait data of 10 neuropathic and 10 healthy subjects. Model validation focused on agreement between FEM-simulated and experimental PP. 相似文献
14.
Si Chen Hangdi Lou Liang Guo Yi Liu 《Computer methods in biomechanics and biomedical engineering》2013,16(3):255-261
Prediction of soft tissue aesthetics is important for achieving an optimal outcome in orthodontic treatment planning. Previously, applicable procedures were mainly restricted to 2-D profile prediction. In this study, a generic 3-D finite element (FE) model of the craniofacial soft and hard tissue was constructed, and individualisation of the generic model based on cone beam CT data and mathematical transformation was investigated. The result indicated that patient-specific 3-D facial FE model including different layers of soft tissue could be obtained through mathematical model transformation. Average deviation between the transformed model and the real reconstructed one was 0.47 ± 0.77 mm and 0.75 ± 0.84 mm in soft and hard tissue, respectively. With boundary condition defined according to treatment plan, such FE model could be used to predict the result of orthodontic treatment on facial soft tissue. 相似文献
15.
N.H. Yang P.K. Canavan H. Nayeb-Hashemi B. Najafi 《Computer methods in biomechanics and biomedical engineering》2013,16(5):589-603
A robust protocol for building subject-specific biomechanical models of the human knee joint is proposed which uses magnetic resonance imaging, motion analysis and force platform data in conjunction with detailed 3D finite element models. The proposed protocol can be used for determining stress and strain distributions and contact kinetics in different knee elements at different body postures during various physical activities. Several examples are provided to highlight the capabilities and potential applications of the proposed protocol. This includes preliminary results on the role of body weight on the stresses and strains induced in the knee articular cartilages and meniscus during single-leg stance and calculations of the induced stresses and ligament forces during the gait cycle. 相似文献
16.
Hanbin Ouyang Yuping Deng Pusheng Xie Yang Yang Bingyun Jiang Canjun Zeng 《Computer methods in biomechanics and biomedical engineering》2017,20(12):1339-1349
Intraarticular calcaneal fractures can result in poor prognosis. Although operative fixation can improve the functional outcomes in most cases, surgical complications such as loss of reduction and wound healing problems may increase the risk of reoperation. Hence, this study aimed to design calcaneal locking plate with a lower profile and better biomechanical performance and to compare the redesigned plate with the traditional calcaneal plate via the finite element method. A Sanders’ type II-C intraarticular calcaneal fracture was simulated. Two fixation models utilising the branch-like calcaneal locking plate and the full plate were constructed. Topology optimisation was conducted to generate a new calcaneal plate design. A biomechanical comparison among the three groups of plates was performed using the finite element method. For the fracture simulated in this study, the optimised plate was superior to the traditional plate in terms of fixation stability and safety but was reduced in volume by approximately 12.34%. In addition, more rational stress distributions were observed in the redesigned plate, underscoring the superiority of this new design in terms of fatigue strength. These results demonstrate that the topology optimisation can be used to design a new implant with a minimised profile and no loss of fixation stability. 相似文献
17.
Estimating the risk of osteoporotic fractures is an important diagnostic step that needs to be taken before medicinal treatment. Densitometry-based criteria are normally used in clinical practice for this purpose. However, densitometry-based techniques could not explain all low-energy fractures. As patient-specific finite element (FE) models allow for consideration of other parameters (e.g. load conditions) that are known to be associated with fracture, they are considered promising candidates for more accurate fracture risk estimation. Nevertheless, they are often time consuming, expensive, and complex to build and may need the type of expertise that is not normally available in clinical settings. In this study, we report the development of an automated platform for estimating proximal femur fracture loads using patient-specific 2D FE models generated using dual-energy x-ray absorptiometry (DXA) scans. First, a statistical shape and appearance model (SSAM) is built using DXA scans of patients screened for osteoporosis following a low energy fracture. SSAM is then used together with Active Appearance Models (AAM) for automated segmentation of the proximal femur from new unseen DXA scans. The mean point-to-curve error of the automated procedure, i.e. 1.2–1.4 mm, is shown to be only slightly larger than the intra-observer variability of manual segmentation, i.e. 1.0 mm. Moreover, the developed platform automatically meshes the segmented shape, assigns density-based mechanical properties, assigns loads and boundary conditions, submits the 2D FE model for solution, and performs post-processing of the 2D FE simulation data to determine fracture loads. The fracture loads predicted using the manually generated and automatically generated 2D FE models are shown to be very close with a mean difference of around 8.8%. Repeated measures ANOVA showed no significant differences between the fracture loads calculated using FE models manually generated by three independent observers and those calculated using the automatically generated FE models (p>0.05). 相似文献
18.
19.
Molly T. Townsend 《Computer methods in biomechanics and biomedical engineering》2016,19(11):1137-1142
Simplified material models are commonly used in computational simulation of biological soft tissue as an approximation of the complicated material response and to minimize computational resources. However, the simulation of complex loadings, such as long-duration tissue swelling, necessitates complex models that are not easy to formulate. This paper strives to offer the updated Lagrangian formulation comprehensive procedure of various non-linear material models for the application of finite element analysis of biological soft tissues including a definition of the Cauchy stress and the spatial tangential stiffness. The relationships between water content, osmotic pressure, ionic concentration and the pore pressure stress of the tissue are discussed with the merits of these models and their applications. 相似文献
20.
T. Oktenoglu A. Kiapour A.F. Ozer I. Lazoglu T. Kaner 《Computer methods in biomechanics and biomedical engineering》2013,16(11):1252-1261
Pedicle screw-based dynamic constructs either benefit from a dynamic (flexible) interconnecting rod or a dynamic (hinged) screw. Both types of systems have been reported in the literature. However, reports where the dynamic system is composed of two dynamic components, i.e. a dynamic (hinged) screw and a dynamic rod, are sparse. In this study, the biomechanical characteristics of a novel pedicle screw-based dynamic stabilisation system were investigated and compared with equivalent rigid and semi-rigid systems using in vitro testing and finite element modelling analysis. All stabilisation systems restored stability after decompression. A significant decrease in the range of motion was observed for the rigid system in all loadings. In the semi-rigid construct the range of motion was significantly less than the intact in extension, lateral bending and axial rotation loadings. There were no significant differences in motion between the intact spine and the spine treated with the dynamic system (P>0.05). The peak stress in screws was decreased when the stabilisation construct was equipped with dynamic rod and/or dynamic screws. 相似文献