首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A high‐throughput sample preparation protocol based on the use of 96‐well molecular weight cutoff (MWCO) filter plates was developed for shotgun proteomics of cell lysates. All sample preparation steps, including cell lysis, buffer exchange, protein denaturation, reduction, alkylation and proteolytic digestion are performed in a 96‐well plate format, making the platform extremely well suited for processing large numbers of samples and directly compatible with functional assays for cellular proteomics. In addition, the usage of a single plate for all sample preparation steps following cell lysis reduces potential samples losses and allows for automation. The MWCO filter also enables sample concentration, thereby increasing the overall sensitivity, and implementation of washing steps involving organic solvents, for example, to remove cell membranes constituents. The optimized protocol allowed for higher throughput with improved sensitivity in terms of the number of identified cellular proteins when compared to an established protocol employing gel‐filtration columns.  相似文献   

2.
Serum protein profiling by MS is a promising method for early detection of disease. Important characteristics for serum protein profiling are preanalytical factors, analytical reproducibility and high throughput. Problems related to preanalytical factors can be overcome by using standardized and rigorous sample collection and sample handling protocols. The sensitivity of the MS analysis relies on the quality of the sample; consequently, the blood sample preparation step is crucial to obtain pure and concentrated samples and enrichment of the proteins and peptides of interest. This review focuses on the serum sample preparation step prior to protein profiling by MALDI MS analysis, with particular focus on various SPE methods. The application of SPE techniques with different chromatographic properties such as RP, ion exchange, or affinity binding to isolate specific subsets of molecules (subproteomes) is advantageous for increasing resolution and sensitivity in the subsequent MS analysis. In addition, several of the SPE sample preparation methods are simple and scalable and have proven easy to automate for higher reproducibility and throughput, which is important in a clinical proteomics setting.  相似文献   

3.
This study compares 16 different extraction methods for the comprehensive extraction of mouse brain proteome in combination with "shotgun"-based mass spectrometry (MS). Membrane proteins (MPs) are responsible for a large part of the regulatory functions of the cell and are therefore of great interest to extract and analyze. Sixteen protein extraction protocols were evaluated in regards to protein yield and number of identified proteins with emphasis on MPs. The extracted proteins were delipidated, on-filter digested, and analyzed by reversed phase nanoliquid chromatography (RP-nanoLC) in combination with electrospray ionization (ESI) tandem mass spectrometry (MS/MS) using a 7 T hybrid LTQ-FT mass spectrometer. Detergent-based lysis buffers showed higher efficiencies and yields in the extraction of proteins from the brain tissue compared to solubilization with organic solvents or organic acids. The detergent octyl-β-D-glucopyranoside gave the highest number of identified proteins (541) as well as numbers and percentages of identified MPs (29%). Detergent-based protocols are the best sample preparation tools for central nervous system (CNS) tissue and can readily be applied to screen for candidate biomarkers of neurological diseases.  相似文献   

4.
Four cell lysis methods (NaOH-SDS solubilization, French press treatment, sonication, mutanolysin treatment) and three methods of protein assays (Lowry, Bradford, Pierce) were studied for their applicability to determination of cell volume in Clostridium perfringens NCTC 8798 cell suspensions. Protein contents were higher after a mechanical disruption of the cells than with the other techniques of lysis. The lowest concentrations of protein were obtained with the Bradford procedure. With each of the three protein assay methods, Clostridium perfringens NCTC 8798 protein cell contents were 45% to 58% of protein. Other factors possibly involved in variations of the intracellular volume measurements were examined. A control of the level of protein concentration in the test sample and the type of silicone oil used for the centrifugation were of prime importance during sample preparation. Under our conditions, an intracellular volume of 4 μl/(mg of protein) was routinely found for Clostridium perfringens NCTC 8798. Received: 11 April 1997 / Accepted: 6 August 1997  相似文献   

5.
Sample preparation is the crucial starting point to obtain high-quality mass spectrometry data and can be divided into two main steps in a bottom-up proteomics approach: cell/tissue lysis with or without detergents and a(n) (in-solution) digest comprising denaturation, reduction, alkylation, and digesting of the proteins. Here, some important considerations, among others, are that the reagents used for sample preparation can inhibit the digestion enzyme (e.g., 0.1% sodium dodecyl sulfate [SDS] and 0.5 M guanidine HCl), give rise to ion suppression (e.g., polyethylene glycol [PEG]), be incompatible with liquid chromatography–tandem mass spectrometry (LC–MS/MS) (e.g., SDS), and can induce additional modifications (e.g., urea). Taken together, all of these irreproducible effects are gradually becoming a problem when label-free quantitation of the samples is envisioned such as during the increasingly popular high-definition mass spectrometry (HDMSE) and sequential window acquisition of all theoretical fragment ion spectra (SWATH) data-independent acquisition strategies. Here, we describe the detailed validation of a reproducible method with sufficient protein yield for sample preparation without any known LC–MS/MS interfering substances by using 1% sodium deoxycholate (SDC) during both cell lysis and in-solution digest.  相似文献   

6.
Protein sample preparation optimisation is critical for establishing reproducible high throughput proteomic analysis. In this study, two different fractionation sample preparation techniques (in‐gel digestion and in‐solution digestion) for shotgun proteomics were used to quantitatively compare proteins identified in Vitis riparia leaf samples. The total number of proteins and peptides identified were compared between filter aided sample preparation (FASP) coupled with gas phase fractionation (GPF) and SDS‐PAGE methods. There was a 24% increase in the total number of reproducibly identified proteins when FASP‐GPF was used. FASP‐GPF is more reproducible, less expensive and a better method than SDS‐PAGE for shotgun proteomics of grapevine samples as it significantly increases protein identification across biological replicates. Total peptide and protein information from the two fractionation techniques is available in PRIDE with the identifier PXD001399 ( http://proteomecentral.proteomexchange.org/dataset/PXD001399 ).  相似文献   

7.
Nowadays, soil diversity is accessed at molecular level by the total DNA extraction of a given habitat. However, high DNA yields and purity are difficult to achieve due to the co-extraction of enzyme-inhibitory substances that inhibit downstream applications, such as PCR, restriction enzyme digestion, and DNA ligation. Therefore, there is a need for further development of sample preparation methods that efficiently can result in pure DNA with satisfactory yield. In this study, the buoyant densities of soil microorganisms were utilized to design a sample preparation protocol where microbial cells could be separated from the soil matrix and enzyme-inhibitory substances by flotation. A discontinuous density gradient was designed using a colloidal solution of non-toxic silanised silica particles (BactXtractor). The method proved to be an efficient alternative to direct extraction protocols where cell lysis is performed in the presence of soil particles. The environmental DNA extracted after flotation had high molecular weight and comparable yield as when using available commercial kits (3.5 μg DNA/g soil), and neither PCR nor restriction enzyme digestion of DNA were inhibited. Furthermore, specific primers enabled recovery of both prokaryotic and eukaryotic sequences.  相似文献   

8.
Hydrophobic membrane proteins often have complex functions and are thus of great interest. However, their analysis presents a challenge because they are not readily soluble in polar solvents and often undergo aggregation. We present a sequential CNBr and trypsin in-gel digestion method combined with mass spectrometry for membrane protein analysis. CNBr selectively cleaves methionine residues. But due to the low number of methionines in proteins, CNBr cleavage produces a small number of large peptide fragments with MWs typically >2000, which are difficult to extract from gel pieces. To produce a larger number of smaller peptides than that obtained by using CNBr alone, we demonstrate that trypsin can be used to further digest the sample in gel. The use of n-octyl glucoside (n-OG) to enhance the digestion efficiency and peptide recovery was also studied. We demonstrate that the sensitivity of this membrane protein identification method is in the tens of picomole regime, which is compatible to the Coomassie staining gel-spot visualization method, and is more sensitive than other techniques reported in the literature. This CNBr/trypsin in-gel digestion method is also found to be very reproducible and has been successfully applied for the analysis of complex protein mixtures extracted from biological samples. The results are presented from a study of the analysis of bacteriorhodopsin, nitrate reductase 1 gamma chain, and a complex protein mixture extracted from the endoplasmic recticulum membrane of mouse liver.  相似文献   

9.
The goal of this study was the development of a method for quantitative expression proteomics on the limited sample amounts obtained through laser capture microdissection (LCM) of tissues, e.g., approximately 10 000 cells, which typically contain roughly 1-4 microg protein. The 16O/18O labeling method was selected as an approach to measure differential expression. A sample preparation protocol including lysis, digestion and 16O/18O labeling was first developed for LCM cell samples. The selected protocol was examined using two LCM caps of 10 000 cells from invasive ductal carcinoma of the breast and shown to be repeatable. A further test of LC-IT-MS/MS in combination with the 16O/18O post-digestion labeling method for studying low level samples was conducted first on a single protein (BSA) and then on a 5-standard protein mixture digest of different protein amounts, each with a total content approximately 1 microg. Next, protein expression was compared between 10 000 cells, each of microdissected normal ductal epithelium and metastatic ductal carcinoma, using the developed method. The proteins from the microdissected cells were extracted, precipitated, digested with trypsin and then 16O/18O labeled. The normal and metastatic cell samples were analyzed using reversed phase LC-ESI-MS/MS on the ion trap mass spectrometer. A total of 76 proteins were identified. Some, such as mitochondrial isocitrate dehydrogenase, actin and 14-3-3 protein xi/delta were found to be significantly up-regulated in the breast tumor cells.  相似文献   

10.
The emergence of MS-based proteomic platforms as a prominent technology utilized in biochemical and biomedical research has increased the need for high-quality MS measurements. To address this need, National Institute of Standards and Technology (NIST) reference material (RM) 8323 yeast protein extract is introduced as a proteomics quality control material for benchmarking the preanalytical and analytical performance of proteomics-based experimental workflows. RM 8323 yeast protein extract is based upon the well-characterized eukaryote Saccharomyces cerevisiae and can be utilized in the design and optimization of proteomics-based methodologies from sample preparation to data analysis. To demonstrate its utility as a proteomics quality control material, we coupled LC-MS/MS measurements of RM 8323 with the NIST MS Quality Control (MSQC) performance metrics to quantitatively assess the LC-MS/MS instrumentation parameters that influence measurement accuracy, repeatability, and reproducibility. Due to the complexity of the yeast proteome, we also demonstrate how NIST RM 8323, along with the NIST MSQC performance metrics, can be used in the evaluation and optimization of proteomics-based sample preparation methods.  相似文献   

11.
A new method for rapid proteolytic digestion of proteins under high pressure that uses pressure cycling technology in the range of 5-35 kpsi was demonstrated for proteomic analysis. Successful in-solution digestions of single proteins and complex protein mixtures were achieved in 60 s and then analyzed by reversed phase liquid chromatography-electrospray ionization ion trap-mass spectrometry. Method performance in terms of the number of Shewanella oneidensis peptides and proteins identified in a shotgun approach was evaluated relative to a traditional "overnight" sample preparation method. Advantages of the new method include greatly simplified sample processing, easy implementation, no cross contamination among samples, and cost effectiveness.  相似文献   

12.
Human lung epithelial cells (A549) were used as a model to develop a reliable proteome characterization method by peptide mass fingerprinting (PMF). Lung cell lysate proteins and protein standards were separated by 2D-gel electrophoresis, stained with Coomassie blue, gel plugs were subjected to commonly adapted as well as optimized in-gel digestion/sample preparation methods. Samples were analyzed by MALDI-TOF-MS. Optimization parameters included, use of NH(4)OAc in destaining and in-gel digestion buffers, detergent/salt removal prior to in-gel digestion, use of solvents of varying polarities (0%, 30%, 60% ACN containing 0.1% TFA) to improve peptide recoveries, matrix composition (alpha-cyano-4-hydroxycinamic acid-organic solvent combinations) and on-target salt removal. This led to enhanced mass spectral information and a sensitivity gain in the order of 6-10 fold compared to that of common procedures, yielding reliable, unambiguous protein identification with femtomol protein sensitivity by Autoflex MALDI-TOF-MS. Triplicate analyses by two analysts revealed consistent, wide range m/z values including in < 1200Da region by relieving matrix-exerted signal suppression, requiring one trial to obtain a unique protein identification with superior PMF results for the optimized method. Analyses of ten A549 proteins in replicates using the optimized method yielded fast, reliable characterization, suggesting the potential application of this method in high-throughput protein identification by PMF.  相似文献   

13.
Efficient protein solubilization using detergents is required for in‐depth proteome analysis, but successful LC‐MS/MS analysis greatly depends on proper detergents removal. A commonly used sample processing method is the filter‐aided sample preparation (FASP), which allows protein digestion and detergent removal on the same filtration device. Many optimizations of the FASP protocol have been published, but there is no information on the influence of the filtration unit typology on the detergents removal. The aim of this study was to compare the performance of conic and flat bottom filtration units in terms of number of proteins identified by LC‐MS/MS. We have analyzed 1, 10 and 100 μg of total cell lysate prepared using lysis buffer with different SDS concentrations. We compared the FASP protocol using conic and flat bottom filtration units to ethanol precipitation method. Subsequently, we applied our most performant protocol to single murine pancreatic islet, and identified up to 2463 protein using FASP versus 1169 proteins using ethanol precipitation. We conclude that FASP performance depends strongly on the filter shape: flat bottom devices are better suited for low‐protein samples, as they allow better SDS removal leading to the identification of greater number of proteins.  相似文献   

14.
The combinations of gel electrophoresis or LC and mass spectrometry are two popular approaches for large scale protein identification. However, the throughput of both approaches is limited by the speed of the protein digestion process. Present research into fast protein enzymatic digestion has been focused mainly on known proteins, and it is unclear whether these results can be extrapolated to complex protein mixtures. In this study microwave technology was used to develop a fast protein preparation and enzymatic digestion method for protein mixtures. The protein mixtures in solution or in gel were prepared and digested by microwave-assisted protein enzymatic digestion, which rapidly produces peptide fragments. The peptide fragments were further analyzed by capillary LC and ESI-ion trap-MS or MALDI-TOF-MS. The technique was optimized using bovine serum albumin and then applied to human urinary proteins and yeast lysate. The method enabled preparation and digestion of protein mixtures in solution (human urinary proteins) or in gel (yeast lysate) in 6 or 25 min, respectively. Equivalent (in-solution) or better (in-gel) digestion efficiency was obtained using microwave-assisted protein enzymatic digestion compared with the standard overnight digestion method. This new application of microwave technology to protein mixture preparation and enzymatic digestion will hasten the application of proteomic techniques to biological and clinical research.  相似文献   

15.
Immobilization of enzymes on some solid supports has been used to stabilize enzymes in organic solvents. In this study, we evaluated applications of genetically immobilized Rhizopus oryzae lipase displayed on the cell surface of Saccharomyces cerevisiae in organic solvents and measured the catalytic activity of the displayed enzyme as a fusion protein with alpha-agglutinin. Compared to the activity of a commercial preparation of this lipase, the activity of the new preparation was 4.4 x 10(4)-fold higher in a hydrolysis reaction using p-nitrophenyl palmitate and 3.8 x 10(4)-fold higher in an esterification reaction with palmitic acid and n-pentanol (0.2% H2O). Increased enzyme activity may occur because the lipase displayed on the yeast cell surface is stabilized by the cell wall. We used a combination of error-prone PCR and cell surface display to increase lipase activity. Of 7,000 colonies in a library of mutated lipases, 13 formed a clear halo on plates containing 0.2% methyl palmitate. In organic solvents, the catalytic activity of 5/13 mutants was three- to sixfold higher than that of the original construct. Thus, yeast cells displaying the lipase can be used in organic solvents, and the lipase activity may be increased by a combination of protein engineering and display techniques. Thus, this immobilized lipase, which is more easily prepared and has higher activity than commercially available free and immobilized lipases, may be a practical alternative for the production of esters derived from fatty acids.  相似文献   

16.
Winter D  Steen H 《Proteomics》2011,11(24):4726-4730
In order to maximize the number of proteins identified from Hela S3 cell lysate we tested various cell lysis, protein precipitation and digestion protocols. First, we compared three different lysis buffers, two mechanical cell disruption methods and two precipitation methods. Then, we tested six different in-solution digestion protocols, three different in-gel digestion protocols and ten different peptide extraction protocols. The result is a proposal for an optimized protocol to prepare the whole cell lysate samples from HeLa S3 cells.  相似文献   

17.
Reliable sample preparation is of utmost importance for comparative proteome analysis, particularly when investigating minute amounts of clinical specimens, such as laser capture microdissected tumor tissue. In this study, we present an optimized nanoLC-MS workflow specifically for the analysis of laser capture microdissected breast cancer tissue. Analytical performance of different laser capture microdissection (LCM) functions available on the PALM system, time dependent trypsin digestion efficiency, effect of sample preparation and digestion time on peptide modification, semi-tryptic peptides and missed cleavages were evaluated. Our results show that microdissection from uncoated glass slides results in protein degradation; that protease and phosphatase inhibitors do not result in detectable improvement in number of peptides or semi-tryptic peptides; and that digestion time longer than four hours drastically reduces the number of missed cleavages, but also increases the number of unexpectedly modified peptides. Overalkylation was the most dominant side-reaction, which significantly increased overnight (P=0.05). The latter effect could almost completely be reverted by the use of a quenching agent (P=0.001). Taken together, our results show that it is of importance to carefully control sample handling steps so that reliable protein identification and quantitation can be performed within comparative proteomics studies using LCM. This article is part of a Special Issue entitled: Proteomics: The clinical link.  相似文献   

18.
Sample preparation is critical to the success of two-dimensional gel electrophoresis and other analytical methods. Pressure-cycling technology (PCT) uses alternating cycles of high and low pressure to induce cell lysis. Cell suspensions were placed in PULSE Tubes and subjected to alternating cycles of high and low pressure in a Barocycler instrument. each cycle consisted of 20 sec at 35,000 psi followed by 20 sec at ambient pressure. For the bacterium Escherichia coli, PCT extracted 14.2% more total protein than was extracted using a standard bead mill. Image analysis of two-dimensional gels revealed 801 protein spots in the PCT lysate, compared to 760 protein spots in the bead mill lysate.  相似文献   

19.
In-gel peptide digestion has become a widely used technique for characterizing proteins resolved by two-dimensional gel electrophoresis. Peptides generated from gel pieces are frequently contaminated with detergent and salts. Prior to matrix-assisted laser desorption/ionization-time of flight mass spectrometry analysis, these contaminants are removed using micro scale C18 sample preparation columns. In this paper, data are presented to demonstrate the application of a solvent resistant MultiScreen 96-well plate with a low peptide binding membrane and ZipTip micropipette based sample preparation. Recoveries of peptides (m/z of 1000 to 5000 Da) derived from standard protein protease digests, were estimated at various stages of the analytical process. An optimized protocol has been established and all the reagents and consumables have been packaged in a ready to use commercial kit. Data will be presented to show the application of this technology package to accelerate the throughput of protein characterization by protease fragmentation.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号