 共查询到20条相似文献,搜索用时 15 毫秒
1.
A comparison of calibration results and procedures in terms of air kerma length product, PKL, and air kerma, K, was conducted between eight dosimetry laboratories. A pencil-type ionization chamber (IC), generally used for computed tomography dose measurements, was calibrated according to three calibration methods, while its residual signal and other characteristics (sensitivity profile, active length) were assessed. The results showed that the “partial irradiation method” is the preferred method for the pencil-type IC calibration in terms of PKL and it could be applied by the calibration laboratories successfully. Most of the participating laboratories achieved high level of agreement (>99%) for both dosimetry quantities (PKL and K). Estimated relative standard uncertainties of comparison results vary among laboratories from 0.34% to 2.32% depending on the quantity, beam quality and calibration method applied. Detailed analysis of the assigned uncertainties have been presented and discussed.  相似文献   

2.
PVC isolators are now widely used for housing animals and provide a readily available pretested air-tight chamber (Pendry, 1984; Trexler, 1984). We have adapted a flexible film isolator for use as a hypoxic chamber for small animals. The environment within the chamber can be easily and continuously monitored with indwelling probes, obviating the need for a separate circuit for gas analysis. This design has been used for long-term studies of chronic hypoxia.  相似文献   

3.
4.
5.
6.
7.
Summary The thermoluminescent dosimetry is currently applied to radiation therapy in order to measure dose distributions on phantoms or to control the dose in vivo for special procedures or critical organs. The application of this method to the SIN's (Switzerland) pion beam has been studied.Measurements have been made on the following thermoluminescent materials:7LiF,6LiF, Li(nat)F, Li2B4O7, CaF2 : Mn, and CaF2 : Dy. Except for the last one a reduction (10%) of the sensitivity of the phosphors has been observed in the peak relative to the plateau region. An increase of the6LiF sensitivity relative to that of7LiF has been pointed out due to the neutron background through the (n,) reaction on6Li. Glow curves of the LiF phosphors have been measured. A reduction (5%) of the intensities of peak 3 and 4 relative to peak 5 has been observed for irradiation in the peak region. This effect however can't be used in order to localize the dosimeter in the beam because the intensity of the thermoluminescence peaks shows a larger variability in a batch of dosimeters.  相似文献   

8.
Bakhtiar R  Ramos L  Tse FL 《Chirality》2001,13(2):63-74
Recent advances in mass spectrometry have rendered it an attractive and versatile tool in industrial and academic research laboratories. As a part of this rapid growth, a considerable body of literature has been devoted to the application of mass spectrometry in studies involving enantioselectivity, molecular recognition, and supramolecular chemistry. In concert with separation techniques such as capillary electrophoresis and liquid chromatography, mass spectrometry allows rapid characterization of a large array of molecules in complex mixtures. A majority of these findings have been made possible by the introduction of 'soft-ionization' techniques such as electrospray ionization interface. Other techniques such as atmospheric pressure chemical ionization mass spectrometry have been widely used as a rugged interface for quantitative liquid chromatography-mass spectrometry. Herein, we present a brief overview of the above techniques accompanied with several examples of enantioselective capillary electrophoresis- and liquid chromatography-mass spectrometry in drug discovery and development. Although the emphasis of this article is on quantitative enantiomeric chromatography-mass spectrometry, we envisage that similar strategies are adaptable in qualitative studies.  相似文献   

9.
10.
This work deals with the dosimetric features of a particular phenolic compound (IRGANOX 1076®) for dosimetry of clinical photon beams by using electron spin resonance (ESR) spectroscopy. After the optimization of the ESR readout parameters (namely modulation amplitude and microwave power) to maximise the signal without excessive spectrum distortions, basic dosimetric properties of laboratory-made phenolic dosimeters in pellet form, such as reproducibility, dose–response, sensitivity, linearity and dose rate dependence were investigated. The dosimeters were tested by measuring the depth dose profile of a 6 MV photon beam. A satisfactory intra-batch reproducibility of the ESR signal of the manufactured dosimeters was obtained. The ESR signal proved to increase linearly with increasing dose in the investigated dose range 1–13 Gy. The presence of an intrinsic background signal limits the minimum detectable dose to a value of approximately 0.6 Gy. Reliable and accurate assessment of the dose was achieved, independently of the dose rate. Such characteristics, together with the fact that IRGANOX 1076® is almost tissue-equivalent, and the stability of the ESR signal, make these dosimeters promising materials for ESR dosimetric applications in radiotherapy.  相似文献   

11.
12.
13.
14.
Two very different techniques for measuring the energy of neutrons in the energy range 0.1-10 MeV are presented and compared. A recoil-proton spectrometer is used to determine the energy spectra of neutrons produced by the d(4)-Be and p(4)-Be reactions down to the low-energy threshold of 0.7 MeV. The same radiation fields are also measured with a recently developed method using a high-pressure ionization chamber that can be used to determine the mean energy of the neutrons in a mixed neutron-gamma radiation field provided the gamma-ray absorbed dose fraction is determined independently. An intercomparison of the two methods shows that the high-pressure ionization chamber compares well and supplements the established recoil-proton spectrometer technique. The almost isotropic response of the chamber has enabled measurements to be made of the variation of mean neutron energy with depth in water for the two radiation fields.  相似文献   

15.
16.
Summary A pressure chamber for use with small leaves can be constructed out of commercially available parts. re]19770203  相似文献   

17.
PurposeRadiochromic films change their color upon irradiation due to polymerization of the sensitive component embedded within the sensitive layer. However, agents, other than monitored radiation, can lead to a change in the color of the sensitive layer (temperature, humidity, UV light) that can be considered as a background signal and can be removed from the actual measurement by using a control film piece. In this work, we investigate the impact of the use of control film pieces on both accuracy and uncertainty of dose measured using radiochromic film based reference dosimetry protocol.MethodsWe irradiated “control” film pieces (EBT3 GafChromicTM film model) to known doses in a range of 0.05–1 Gy, and five film pieces of the same size to 2, 5, 10, 15 and 20 Gy, considered to be “unknown” doses. Depending on a dose range, two approaches to incorporating control film piece were investigated: signal and dose corrected method.ResultsFor dose values greater than 10 Gy, the increase in accuracy of 3% led to uncertainty loss of 5% by using dose corrected approach. At lower doses and signals of the order of 5%, we observed an increase in accuracy of 10% with a loss of uncertainty lower than 1% by using the corrected signal approach.ConclusionsIncorporation of the signal registered by the control film piece into dose measurement analysis should be a judgment call of the user based on a tradeoff between deemed accuracy and acceptable uncertainty for a given dose measurement.  相似文献   

18.
Summary A mammalian tissue culture chamber was utilized in a developmental study of two aquatic fungi. This apparatus was found to provide a simple system by which aquatic microorganisms could be continuously cultured and their development directly observed under precisely controlled environmental conditions.  相似文献   

19.
20.
PurposeThe increasing interest in SBRT treatments encourages the use of flattening filter free (FFF) beams. Aim of this work was to evaluate the performance of the PTW60019 microDiamond detector under 6 MV and 10MVFFF beams delivered with the EDGE accelerator (Varian Medical System, Palo Alto, USA). A flattened 6 MV beam was also considered for comparison.MethodsShort term stability, dose linearity and dose rate dependence were evaluated. Dose per pulse dependence was investigated in the range 0.2–2.2 mGy/pulse. MicroDiamond profiles and output factors (OFs) were compared to those obtained with other detectors for field sizes ranging from 40 × 40 cm2 to 0.6 × 0.6 cm2. In small fields, volume averaging effects were evaluated and the relevant correction factors were applied for each detector.ResultsMicroDiamond short term stability, dose linearity and dependence on monitor unit rate were less than 0.8% for all energies. Response variations with dose per pulse were found within 1.8%. MicroDiamond output factors (OF) values differed from those measured with the reference ion-chamber for less than 1% up to 40 × 40 cm2 fields where silicon diodes overestimate the dose of ≈3%. For small fields (<3 × 3 cm2) microDiamond and the unshielded silicon diode were in good agreement.ConclusionsMicroDiamond showed optimal characteristics for relative dosimetry even under high dose rate beams. The effects due to dose per pulse dependence up to 2.2 mGy/pulse are negligible. Compared to other detectors, microDiamond provides accurate OF measurements in the whole range of field sizes. For fields <1 cm correction factors accounting for fluence perturbation and volume averaging could be required.  相似文献   