首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
N. Gupta, D. John, N. Dudding, J. Crossley and J. H. F. Smith
Factors contributing to false‐negative and potential false‐negative cytology reports in SurePath ? liquid‐based cervical cytology Objectives: The characteristics of false‐negative conventional cervical cytology smears have been well documented, but there is limited literature available for liquid‐based cytology (LBC), especially SurePath? samples. We aimed to assess the characteristics of false‐negative SurePath LBC samples. Methods: Over a period of 5 years, an audit of false‐negative reports in SurePath cervical cytology was undertaken. In a workload of 183, 112 samples, 481 (0.3%) false negatives were identified using two routes: those detected by routine laboratory internal quality control (rapid pre‐screening) (n = 463) and those reported as normal (true false negatives) with concurrent high‐grade cervical histology (n = 18). Ninety‐five false‐negative cases with a subsequent biopsy reported as at least cervical intraepithelial neoplasia grade 2 (CIN2+) were reviewed for a number of different cytomorphological features. Results: Of 95 samples with subsequent CIN2+, 30.5% predominately contained microbiopsies/hyperchromatic crowded cell groups (HCGs), 27.3% sparse dyskarytotic cells, 4.2% pale cell dyskaryosis, 6.3% small dyskaryotic cells; 3.2% were misinterpreted cells, 8.4% contained other distracting cells, 7.4% were low contrast, 5.3% were unexplained and 7.4% were true negatives. The mean number of microbiopsies/HCGs in that category was 4.6. The mean number of abnormal cells in the sparse dyskaryotic cell category was 13.8. Conclusions: Microbiopsies/HCGs were the commonest reason for false negatives. They were usually present in sufficient numbers to be detected but interpretation could be problematic. Dispersed single abnormal cells were usually not identified because of their scarcity or the presence of distracters.  相似文献   

3.
4.
5.
6.
7.
T. Hansen, H. Pedersen, V. Brauner and J. Hariri Control specimens for immunocytochemistry in liquid‐based cytology Objective Immunostaining necessitates the use of positive as well as negative controls, which is usually an easy procedure in immunohistochemistry (IHC). To find suitable control specimens for immunocytochemistry (ICC) is, on the other hand, a challenging task and to the best of our knowledge is not sufficiently dealt with in the English literature. The aim of this trial was to develop an applicable method to select, collect, process and store control specimens for ICC using liquid‐based cytology (LBC). Methods The study included 21 different antibodies, which were known to react with at least one of the cellular components from tonsils, serous fluids and bronchial washings. The LBC specimens from the tonsils were collected as SurePath? specimens (BD, Bencton, Dickinson and Company) by brushing the cut‐surface of a fresh tonsil and then immersing the brush head into the SurePath? vial. The serous fluids and bronchial washings were fixed in CytoRich Red? (BD). Some of the cellular suspensions from the tonsils and equal amounts of the serous fluid and the bronchial washings were also mixed as a cocktail. Unstained SurePath slides were then prepared on the PrepStain? (BD) Non‐GYN Program, and the unstained and dry slides were then stored at 5 °C to test the effect of storage on the preservation of the antigenicity. ICC was then performed on BenchMark‐XT?. Results Cellular components in unstained SurePath? slides reacted positively with relevant antibodies. Slides that were stored for up to 40 days did not loose staining intensity. Conclusion Specimens from body fluids and cell‐suspensions that are collected by brushing the cut‐surface from different types of fresh tissues or organs can be used as control specimens either separately or as mixtures. Dry and unstained slides can then be prepared and stored in a refrigerator for at least 40 days without loosing staining intensity.  相似文献   

8.
There is growing evidence that molecular testing is feasible on all types of cytological preparation, which is fortunate as more diagnostic markers and biomarkers for targeted therapies are discovered for use in pulmonary and pleural malignancies. In this article we will discuss the pre-analytic, analytic, and post-analytic (interpretive) considerations for successful implementation of molecular tests for diagnostic and predictive markers in respiratory and pleural cytology. The vast majority of laboratories are familiar with, and have validated their molecular protocols for, formalin-fixed paraffin-embedded surgical specimens, which are not directly applicable to cytology specimens. Thus, rigorous validation must be performed for each type of fixative and cytology preparation before it is implemented in the clinical setting.  相似文献   

9.
10.
L. Skoog  E. Tani 《Cytopathology》2011,22(4):215-229
L. Skoog and E. Tani Immunocytochemistry: an indispensable technique in routine cytology Immunocytology is today accepted as an indispensable adjunct to cytomorphology. It has led to a dramatic increase in diagnostic accuracy and also allowed the identification of markers both for prognosis and targeted therapies. Most commercially available antibodies will perform in a reproducible and reliable way provided that the cytological specimen has been prepared and fixed properly. In this review various aspects of immunocytochemistry such as preparation of cytological specimens, fixation and choice of antibodies will be discussed. The specificity of the most commonly used antibodies is summarized and staining panels for various tumours are suggested. In addition, the use of markers for targeted therapy and theranostics is discussed, as well as a brief section on the identification of infectious agents.  相似文献   

11.
O. E. O. Hotonu, J. Hussey, M. S. T. Basta, V. Wadehra, P. Cross and M. L. Schmid
An audit of cervical cytology in HIV‐positive women Objective: To investigate whether a cohort of human immunodeficiency virus‐positive (HIV+) women were having annual cervical cytology as recommended by the English National Health Service cervical screening programme (NHSCSP) guidelines. Methods: An audit of cervical cytology in an HIV+ cohort of 187 women by obtaining their last cervical cytology result and recall from local cytology services. Results: Of the 187 women in the audit, two were ineligible, leaving 185 women, 167 (90.3%) of whom were aged 25–64 years and eligible for screening. Of the 185 women, 126 (68.1%) had a cytology history, 50 (27%) had never had cervical cytology and nine (4.9%) had inadequate details to ascertain whether or not they had a cytology history. Of the 126 with a cytology record, 34 (27%) had a current cytological abnormality, which was low grade in 25 (19.8%) and high grade in nine (7.1%). Among women aged 25–64 years attending the clinic, these percentages were significantly higher than expected for England as a whole (P < 0.001). Of 126 women with a cytology record, 29 (23%) were overdue for their recall date and of these the previous test was abnormal in 14 (48.3%). Cytology tests were taken within the community setting in 61 (48.4%), whereas 65 (51.6%) were seen either at an HIV sexual health clinic or were under colposcopy follow‐up. Of 91 women with negative cytology only 50 (54.9%) were recommended for repeat in 12 months. Conclusion: This audit demonstrates a high rate of cytological abnormalities among HIV+ women compared with the screening population at large. Implementation of NHSCSP guidelines has been difficult and requires improved care pathways between HIV clinics, primary care and laboratories.  相似文献   

12.
13.
14.
A. Lalzad, D. Ristitsch, W. Downey, A. F. Little and M. E. Schneider‐Kolsky
Effect of ultrasound transmission gel on ultrasound‐guided fine needle aspiration cytological specimens of thyroid Objective: To investigate prospectively the diagnostic impact of ultrasound coupling gel on thyroid specimens obtained under ultrasound guidance. Methods: Patients presenting for ultrasound‐guided fine needle aspiration (USG‐FNA) of the thyroid were invited to participate in the study. Four specimens per nodule were collected: two using chlorhexdine wash and two using sterile, colourless ultrasound gel as couplant according to routine protocol. All slides were analysed in a blinded fashion by two senior cytologists for the presence or absence of ultrasound gel‐induced artefacts. The presence of gel‐induced artefacts between the two groups was analyzed using Pearson’s chi‐square test. Kappa statistics were used to measure the inter‐rater agreement between the cytologists. Results: Twenty thyroid nodules comprising 80 specimen slides were collected. On slides collected with gel, cytological artefacts were detected in 60–65% of cases compared with 10–15% of cases without gel (P < 0.001). The inter‐rater agreement between the two observers was very good (κ = 0.84). Two of the 14 patients required repeat FNA due to non‐diagnostic cytology results caused by inadequate sampling and gel‐induced artefacts. Conclusions: Clinical cytopathologists, radiologists and sonographers should be aware of the potential for ultrasound gel to cause significant artefacts on cytological specimens. Our findings suggest that staff involved in USG‐FNA cytology should remove the gel carefully before taking the aspirate.  相似文献   

15.
J. Choi, H. S. Shim, J.‐W. Song, S. W. Chae, Y.‐N. Lee, J. E. Kim and S. H. Kim
Image analysis of peripheral compression artefacts of ThinPrep® liquid‐based cytology preparations Objective: ThinPrep (TP), one of the Food and Drug Administration‐approved liquid‐based cytology (LBC) preparations, is widely used for gynaecological and non‐gynaecological cytology samples. A unique physical artefact caused by the compression at the periphery in TP slides has not been adequately evaluated to date. Methods: We processed four established tumour cell lines (MKN28, MKN45, KG‐1 and NB4) and mononuclear cells isolated from whole blood over Ficoll‐Plaque for TP preparations. For this part of the study, we included five normal cervical LBC preparations. We then auto‐counted and auto‐measured the area, mean grey value and Feret’s diameter in both the inner disc and peripheral rim of the preparations by image morphometry. In addition, we compared the distribution of atypical cell groups in the peripheral rim and inner disc of 132 lung aspirates, 80 thyroid aspirates, 212 cerebrospinal fluids (CSFs) and 50 gynaecological samples. Results: The areas and Feret’s diameters of the cytoplasm in the peripheral compressed rim area were statistically larger than those of cells in the inner disc. The mean grey values of cells (cytoplasm and nucleus) in the peripheral compression rim were also smaller than those in the inner disc cells, leading to decreases in nuclear and cytoplasmic chromatism. Except for the mean grey values, the differences were not significant in the cervical samples. Conclusions: Cellular morphology may be markedly distorted in the peripheral rim, regardless of cell malignancy, which may lead to the misinterpretation of cells during the screening. Accordingly, cytological diagnosis based on the findings within the peripheral rim should take this phenomenon into account. Compressed cells found in the peripheral rim should be interpreted with caution when TP slides are used for cytopathological diagnosis.  相似文献   

16.
This study examines the performance of the preliminary, on-site interpretation by the pathologist of fine needle aspiration (FNA) cytology smears compared to the final cytology report, the frozen section diagnosis and the final histopathological report. We found that both the preliminary and the final cytology reports gave satisfactory results over the minimum standards for quality assurance required by both the Norwegian breast screening programme and the NHS BSP in the UK with the exception of the 'suspicious' rate. We noted that the preliminary report had fewer false negatives (2.1%) than the final report (4.3%). We show that an unequivocal cytological diagnosis of malignancy is a reliable diagnosis, and in cases where mammography/ultrasonography and clinical examination are in agreement with FNA, frozen section examination is unnecessary. However, cases with a suspicious or equivocal FNA should be considered for frozen section analysis.  相似文献   

17.
18.
19.
A 3-year study assessed the diagnostic accuracy of touch imprint smears in the diagnosis of lung cancer. Touch imprint smears were prepared from 90 computerized tomographic-guided core needle lung biopsies. Cytological diagnosis of touch imprint smears were correlated with the histological diagnosis of the corresponding core needle biopsy specimen, which was taken as the gold standard. The sensitivity, specificity, positive predictive value and negative predictive value of imprint smear results were 89%, 100%, 100% and 68%, respectively. There were no false positives, and all patients with small cell lung cancer were correctly diagnosed with this technique. Imprint cytology can be used to provide a rapid, preliminary diagnosis of lung cancer.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号