首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Three different methods of estimating airborne bacteria were compared. An Anderson sampler, a slit sampler, an impinger, and filter samplers with gelatine filters or membrane filters were tested for collection efficiency. The comparisons were made in laboratory experiments with an aerosol of Staphylococcus epidermidis or Serratia marcescens, in field experiments in two different industries, i.e., cotton mill and sewage plant, and in experiments with skin fragment sampling. Experiments were also performed estimating the total number of viable microorganisms on the airborne particles. The Andersen sampler gave the highest bacterial counts in all environments tested. The slit sampler gave statistically lower counts only in the aerosol experiments and cotton mill experiments, where the size of the majority of the particles carrying visible bacteria was 2 to 6 micrometers or smaller. In the sewage plant and skin fragment experiments, where the particles were mainly 5 micrometers or larger, the difference was not significant. The filters were efficient in sampling in skin fragment experiments only. With the agar impingement method, the total viable cell count showed a rising index value with increasing particle size. A mean of 13 bacteria was found per particle in the cotton mill, a mean of 24 in the sewage plant, and a mean of 147 in skin fragment experiments.  相似文献   

2.
Virus removal filtration is a critical step in the manufacture of monoclonal antibody products, providing a robust size-based removal of both enveloped and non-enveloped viruses. Many monoclonal antibodies show very large reductions in filtrate flux during virus filtration, with the mechanisms governing this behavior and its dependence on the properties of the virus filter and antibody remaining largely unknown. Experiments were performed using the highly asymmetric Viresolve® Pro and the relatively homogeneous Pegasus™ SV4 virus filters using a highly purified monoclonal antibody. The filtrate flux for a 4 g/L antibody solution through the Viresolve® Pro decreased by about 10-fold when the filter was oriented with the skin side down but by more than 1000-fold when the asymmetric filter orientation was reversed and used with the skin side up. The very large flux decline observed with the skin side up could be eliminated by placing a large pore size prefilter directly on top of the virus filter; this improvement in filtrate flux was not seen when the prefilter was used inline or as a batch prefiltration step. The increase in flux due to the prefilter was not related to the removal of large protein aggregates or to an alteration in the extent of concentration polarization. Instead, the prefilter appears to transiently disrupt reversible associations of the antibodies caused by strong intermolecular attractions. These results provide important insights into the role of membrane morphology and antibody properties on the filtrate flux during virus filtration.  相似文献   

3.
The flux of He and O2 through intact adult human skin was measured at various inspired concentrations and skin temperatures. The skin surface was then stripped with cellophane tape to alter the diffusional conductance of the stratum corneum. He flux for stripped skin was used to estimate skin perfusion as a function of local temperature, and diffusional conductance for O2 was estimated from O2 flux and perfusion. The flux of He or O2 at constant skin temperature can be related to inspired concentration by a simple linear model. Increasing surface temperature in the range 33-43 degrees C produced a much larger increase in O2 flux than in He flux for intact skin. Skin stripping greatly increased skin O2 flux. Estimated skin conductance for O2 showed a more marked temperature dependence than estimated skin perfusion. The results suggest that raising skin temperature in the range 38-43 degrees C has only a modest effect on skin perfusion and that stratum corneum conductance may have a major role in the large increase of O2 flux with temperature.  相似文献   

4.
Simon  N. S.  Kennedy  M. M.  Massoni  C. S. 《Hydrobiologia》1985,126(2):135-141
Field and laboratory evaluations were made of a simple, inexpensive diffusion-controlled sampler with ports on two sides at each interval which incorporates 0.2-m polycarbonate membrane to filter samples in situ. Monovalent and divalent ions reached 90% of equilibrium between sampler contents and the external solution within 3 and 6 hours, respectively. Sediment interstitial water chemical gradients to depths of tens of centimeters were obtained within several days after placement. Gradients were consistent with those determined from interstitial water obtained by centrifugation of adjacent sediment. Ten milliliter sample volumes were collected at 1-cm intervals to determine chemical gradients and dissolved oxygen profiles at depth and at the interface between the sediment and water column. The flux of dissolved species, including oxygen, across the sediment-water interface can be assessed more accurately using this sampler than by using data collected from benthic cores.  相似文献   

5.
Air quality within and around confined animal housing operations is important from both occupational exposure and environmental quality perspectives. Appropriate sampling equipment should be available so that bioaerosols are adequately characterized in terms of their component microbial populations. In this study the efficacy of a commercially available impaction-based bioaerosol sampler (SAS-100) was evaluated in terms of its ability to detect male-specific coliphages within and around poultry broiler houses. In addition to the manufacturer recommended agar medium, cellulose and cellulose-acetate filter media were also used as the collection surface. The agar medium and the cellulose ester filters provided very high recoveries of phages as compared to the cellulose filter (P<0.05). There was a wide range of recoveries ranging from 0–100% when the cellulose acetate filter was used to detect phages in bioaerosols within and around broiler houses. The results suggest that the sampler is capable of concentrating male-specific coliphages from bioaerosols. However, further studies are still needed to accurately determine the collection efficiencies of viruses.  相似文献   

6.
Vertical flow filters and vertical flow constructed wetlands are established wastewater treatment systems and have also been proposed for the treatment of contaminated groundwater. This study investigates the removal processes of volatile organic compounds in a pilot-scale vertical flow filter. The filter is intermittently irrigated with contaminated groundwater containing benzene, MTBE and ammonium as the main contaminants. The system is characterized by unsaturated conditions and high contaminant removal efficiency. The aim of the present study is to evaluate the contribution of biodegradation and volatilization to the overall removal of benzene and MTBE. Tracer tests and flow rate measurements showed a highly transient flow and heterogeneous transport regime. Radon-222, naturally occurring in the treated groundwater, was used as a gas tracer and indicated a high volatilization potential. Radon-222 behavior was reproduced by numerical simulations and extrapolated for benzene and MTBE, and indicated these compounds also have a high volatilization potential. In contrast, passive sampler measurements on top of the filter detected only low benzene and MTBE concentrations. Biodegradation potential was evaluated by the analysis of catabolic genes involved in organic compound degradation and a quantitative estimation of biodegradation was derived from stable isotope fractionation analysis. Results suggest that despite the high volatilization potential, biodegradation is the predominant mass removal process in the filter system, which indicates that the volatilized fraction of the contaminants is still subject to subsequent biodegradation. In particular, the upper filter layer located between the injection tubes and the surface of the system might also contribute to biodegradation, and might play a crucial role in avoiding the emission of volatilized contaminants into the atmosphere.  相似文献   

7.
Protein recovery from a bacterial lysate was accomplished using microfiltration membranes in a flat crossflow filter and in a cylindrical rotary filter. Severe membrane fouling yielded relatively low long-term permeate flux values of 10(-4)-10(-3) cm/s (where I cm/s = 3.6 x 10(4) L/m(2) - h). The permeate flux was found to be nearly independent of transmembrane pressure and to increase with increasing shear rate and decreasing solids concentration. The flux increased with shear to approximately the one-third power or greater for the flat filter and the one-half power or greater for the rotary filter; the stronger dependence for the rotary filter is thought to result from Taylor vortices enhancing the back transport of debris carried to the membrane surface by the permeate flow. The average protein transmission or sieving coefficient was measured at approximately 0.6, but considerable scatter in the transmission data was observed. The largest sieving coefficients were obtained for dilute suspensions at high shear rate. The rotary filter provided higher fluxes than did the flat filter for dilute suspensions, but not for concentrated suspensions. (c) 1995 John Wiley & Sons, Inc.  相似文献   

8.
Two commonly used sampling devices (a wind tunnel and the US EPA dynamic emission chamber), were used to collect paired samples of odorous air from a number of agricultural odour sources. The odour samples were assessed using triangular, forced-choice dynamic olfactometry. The odour concentration data was combined with the flushing rate data to calculate odour emission rates for both devices on all sources. Odour concentrations were consistently higher in samples collected with a flux chamber (ratio ranging from 10:7 to 5:1, relative to wind tunnel samples), whereas odour emission rates were consistently larger when derived from wind tunnels (ratio ranging from 60:1 to 240:1, relative to flux chamber values). A complex relationship existed between emission rate estimates derived from each device, apparently influenced by the nature of the emitting surface. These results have great significance for users of odour dispersion models, for which an odour emission rate is a key input parameter.  相似文献   

9.
A method for the automated filtration of protein hydrolyzates prior to amino acid analysis is described. Minor modification of a Technicon Sampler II enables it to function simultaneously as a sampler and a filtrate collector. Samples are drawn from cups in the sampler tray and are forced through a Teflon filter (pore size, 0.2 μm) in a Millipore Swinnex filter holder by a variable-speed Technicon proportioning pump. The filtrates are collected in cups in the sampler tray opposite those containing unfiltered hydrolyzates. Using this technique, 12 hydrolyzates can be filtered in 25 min compared to the approximately 2 h of technician time required for their manual filtration. Aliquots from each of 48 samples representing different proteins and hydrolysis conditions are filtered manually and by the automated technique. Analysis of variance of the resulting recoveries of each amino acid indicate little likelihood of effects due to filtration method.  相似文献   

10.
When amphibian skin was incubated under conditions in which transepithelial sodium transport was abolished, a conductive transepithelial Cl- flux arose when Cl- was removed from one of the compartments. This flux was matched by short-circuit current and it accounted entirely for transepithelial conductance. Cl- influx was larger than efflux; it was linearly related to the magnitude of transepithelial Cl- concentration difference. When applied to the epithelial surface of the tissue, divalent metal cations such as Co2+, and the ethacrynic acid derivative, indacrinone, reduced rapidly and reversibly both transepithelial Cl- (in)flux and short-circuit current. Frog skin proved to be more sensitive to these inhibitors than toad skin. Further characterization of transepithelial Cl- pathway(s) should benefit from the fact that Cl- across amphibian skin can easily be monitored by the short-circuit current method, and from the availability of agents which inhibit this passive flux rapidly and reversibly.  相似文献   

11.
The dairy industry adds starter bacterial cultures to heat-treated milk to control the fermentation process during the manufacture of many cheeses. These highly concentrated bacterial populations are susceptible to virulent phages that are ubiquitous in cheese factories. In this study, the dissemination of these phages by the airborne route and their presence on working surfaces were investigated in a cheese factory. Several surfaces were swabbed, and five air samplers (polytetrafluoroethylene filter, polycarbonate filter, BioSampler, Coriolis cyclone sampler, and NIOSH two-stage cyclone bioaerosol personal sampler) were tested. Samples were then analyzed for the presence of two Lactococcus lactis phage groups (936 and c2), and quantification was done by quantitative PCR (qPCR). Both lactococcal phage groups were found on most swabbed surfaces, while airborne phages were detected at concentrations of at least 10(3) genomes/m(3) of air. The NIOSH sampler had the highest rate of air samples with detectable levels of lactococcal phages. This study demonstrates that virulent phages can circulate through the air and that they are ubiquitous in cheese manufacturing facilities.  相似文献   

12.
A series of experiments was conducted to explore the utility of composite-based collection of surface samples for the detection of a Bacillus anthracis surrogate using cellulose sponge samplers on a nonporous stainless steel surface. Two composite-based collection approaches were evaluated over a surface area of 3716 cm2 (four separate 929 cm2 areas), larger than the 645 cm2 prescribed by the standard Centers for Disease Control (CDC) and Prevention cellulose sponge sampling protocol for use on nonporous surfaces. The CDC method was also compared to a modified protocol where only one surface of the sponge sampler was used for each of the four areas composited. Differences in collection efficiency compared to positive controls and the potential for contaminant transfer for each protocol were assessed. The impact of the loss of wetting buffer from the sponge sampler onto additional surface areas sampled was evaluated. Statistical tests of the results using ANOVA indicate that the collection of composite samples using the modified sampling protocol is comparable to the collection of composite samples using the standard CDC protocol (p  =  0.261). Most of the surface-bound spores are collected on the first sampling pass, suggesting that multiple passes with the sponge sampler over the same surface may be unnecessary. The effect of moisture loss from the sponge sampler on collection efficiency was not significant (p  =  0.720) for both methods. Contaminant transfer occurs with both sampling protocols, but the magnitude of transfer is significantly greater when using the standard protocol than when the modified protocol is used (p<0.001). The results of this study suggest that composite surface sampling, by either method presented here, could successfully be used to increase the surface area sampled per sponge sampler, resulting in reduced sampling times in the field and decreased laboratory processing cost and turn-around times.  相似文献   

13.
In this report we describe the results of a study conducted to determine the rates of bacterial aerosol emission from the surfaces of the aeration tanks of the Metropolitan Water Reclamation District of Greater Chicago John E. Egan Water Reclamation Plant. This study was accomplished by conducting test runs in which Andersen six-stage viable samplers were used to collect bacterial aerosol samples inside a walled tower positioned above an aeration tank liquid surface at the John E. Egan Water Reclamation Plant. The samples were analyzed for standard plate counts (SPC), total coliforms (TC), fecal coliforms, and fecal streptococci. Two methods of calculation were used to estimate the bacterial emission rate. The first method was a conventional stack emission rate calculation method in which the measured air concentration of bacteria was multiplied by the air flow rate emanating from the aeration tanks. The second method was a more empirical method in which an attempt was made to measure all of the bacteria emanating from an isolated area (0.37 m2) of the aeration tank surface over time. The data from six test runs were used to determine bacterial emission rates by both calculation methods. As determined by the conventional calculation method, the average SPC emission rate was 1.61 SPC/m2/s (range, 0.66 to 2.65 SPC/m2/s). As determined by the empirical calculation method, the average SPC emission rate was 2.18 SPC/m2/s (range, 1.25 to 2.66 SPC/m2/s). For TC, the average emission rate was 0.20 TC/m2/s (range, 0.02 to 0.40 TC/m2/s) when the conventional calculation method was used and 0.27 TC/m2/s (range, 0.04 to 0.53 TC/m2/s) when the empirical calculation method was used.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
The influence of several operating parameters on the critical flux in the separation of lactic acid-producing bacteria from fermentation broth was studied using a ceramic microfiltration membrane equipped with a permeate pump. The operating parameters studied were crossflow velocity over the membrane, bacterial cell concentration, protein concentration, and pH. The influence of the isoelectric point (IEP) of the membrane was also investigated. In the interval studied (5.3-10.8 m/s), the crossflow velocity had a marked effect on the critical flux. When the crossflow velocity was increased the critical flux also increased. The bacterial cells were retained by the membrane and the concentration of bacterial cells did not affect the critical flux in the interval studied (1.1-3.1 g/L). The critical flux decreased when the protein concentration was increased. It was found that the protein was adsorbed on the membrane surface and protein retention occurred even though the conditions were such that no filter cake was present on the membrane surface. When the pH of the medium was lowered from 6 to 5 (and then further to 4) the critical flux decreased from 76 L/m(2)h to zero at both pH 5 and pH 4. This was found to be due to the fact that the lowering in pH had affected the physiology of the bacterial cells so that the bacteria tended to adhere to the membrane and to each other. The critical flux, for wheat flour hydrolysate without particles, was much lower (28 L/m(2)h) when using a membrane with an IEP of 5.5 than the critical flux of a membrane with an IEP at pH 7 (96 L/m(2)h). This was found to be due to an increased affinity of the bacteria for the membrane with the lower IEP.  相似文献   

15.
Sunscreen enhancement of UV-induced reactive oxygen species in the skin   总被引:1,自引:0,他引:1  
The number of UV-induced (20 mJ cm(-2)) reactive oxygen species (ROS) generated in nucleated epidermis is dependent upon the length of time the UV filter octocrylene, octylmethoxycinnamate, or benzophenone-3 remains on the skin surface. Two-photon fluorescence images acquired immediately after application of each formulation (2 mg cm(-2)) to the skin surface show that the number of ROS produced is dramatically reduced relative to the skin-UV filter control. After each UV filter remains on the skin surface for t=20 min, the number of ROS generated increases, although it remains below the number generated in the control. By t=60 min, the filters generate ROS above the control. The data show that when all three of the UV filters penetrate into the nucleated layers, the level of ROS increases above that produced naturally by epidermal chromophores under UV illumination.  相似文献   

16.
Gut  A.  Neftel  A.  Staffelbach  T.  Riedo  M.  Lehmann  B.E. 《Plant and Soil》1999,216(1-2):165-180
The surface flux of nitric oxide from a wheat field was investigated from 23 March to 29 May 1997 in the Kerzersmoos, Switzerland. A plot fertilised with 19 kg N ha-1 in cattle slurry and 40 kg N ha-1 in mineral NH4NO3 fertiliser and a plot receiving no nitrogen containing fertiliser were compared. The flux was calculated based on hourly measurements of the NO soil–atmosphere concentration gradient using the one-dimensional soil diffusion model of Galbally and Johansson (1989). The soil bulk diffusion coefficient was determined from measurements of the 222Rn surface flux and the activity gradient between 10 cm depth and the surface. It ranged between 79% and 0.3% of the NO diffusion coefficient in air and was parameterised by air filled soil pore space. The indirectly determined NO flux agreed well with standard flux measurements using dynamic chambers. The largest NO emission was found following fertiliser application and irrigation. The emission occurred in pulses, which lasted for 4 days up to 3 weeks coinciding with elevated soil ammonium concentrations. Nitric oxide emission in 5 days following application of cattle slurry were 31 g NO-N ha-1 and 5 g NO-N ha-1 from the non-fertilised plot, respectively. Nitric oxide emission in 15 days following application of NH4NO3 was 95 g NO-N ha-1 and 10 g NO-N ha-1 from the non-fertilised plot, respectively. NO emission in 4 days following irrigation on 21 April were 36 g N ha-1 from the fertilised and 39 g N ha-1 from the non-fertilised plot. The daily NO emission before and after fertiliser and irrigation pulses was between 0.3 and 0.7 g NO-N ha-1 d-1. NO production and NO uptake of the soil was measured regularly. No systematic influence of management or climate on NO uptake was found. NO production was strongly stimulated by fertiliser input and soil moisture content. The simulation of NO production could be reproduced using a nitrification algorithm (Riedo et al., 1998) driven by soil temperature, moisture and ammonium concentration. A NO production rate constant of 1.1ċ10-3 h-1 at 15 °C was derived from a linear regression between nitrification and NO production. Introducing the parameterisation of NO production into the model of Galbally and Johansson (1989) the duration and the strength of the NO emission pulses could be reproduced and the total NO emission during the experiment was approximated within a factor of two. This revised version was published online in June 2006 with corrections to the Cover Date.  相似文献   

17.
Snow surface-to-air exchange of gaseous elemental mercury (GEM) was measured using a modified Teflon fluorinated ethylene propylene (FEP) dynamic flux chamber (DFC) in a remote, open site in Potsdam, New York. Sampling was conducted during the winter months of 2011. The inlet and outlet of the DFC were coupled with a Tekran Model 2537A mercury (Hg) vapor analyzer using a Tekran Model 1110 two port synchronized sampler. The surface GEM flux ranged from −4.47 ng m−2 hr−1 to 9.89 ng m−2 hr−1. For most sample periods, daytime GEM flux was strongly correlated with solar radiation. The average nighttime GEM flux was slightly negative and was not well correlated with any of the measured meteorological variables. Preliminary, empirical models were developed to estimate GEM emissions from snow surfaces in northern New York. These models suggest that most, if not all, of the Hg deposited with and to snow is reemitted to the atmosphere.  相似文献   

18.
Skin penetration by infective Ancylostoma tubaeforme larvae has been investigated cinematographically and using in vitro techniques. The dermal tissue appears to cause little hinderance to larval migration but complete penetration through the skin from the dermal direction did not occur, although total penetration from the epidermal surface was frequently accomplished. No evidence could be found for enzymic secretions emanating from the worms under conditions that gave positive results from Necator americanus and Strongyloides fülleborni infective larvae. The results indicated that A. tubaeforme was able to penetrate without the use of enzymic secretions and an alternative, mechanical mechanism for penetration is advanced.  相似文献   

19.
长期不同施肥制度下湖南红壤晚稻田CH4的排放   总被引:12,自引:0,他引:12  
刘金剑  吴萍萍    谢小立  傅心赣  沈其荣  郭世伟   《生态学报》2008,28(6):2878-2878~2886
选取湖南双季稻田长期不同施肥制度为研究对象,采用静态箱-气相色谱法对晚稻稻田甲烷排放进行观测.研究结果表明,不同施肥制度下的晚稻稻田甲烷排放的季节变化具有一定的规律,晚稻生育期内CH4的排放速率呈先升高后降低的变化趋势.施入秸秆的处理CH4平均排放通量和累积排放通量大于单施化肥的处理;单施化肥的各处理中由于养分缺失情况的不同,CH4平均排放通量和累积排放量具有一定的差异.秸秆区CH4平均排放通量和累积排放量都较大,全量化肥养分施肥区次之,偏施养分和无肥区较小.同时还研究了长期不同施肥制度条件下各环境因素包括土壤温度、灌溉水层深度和土壤Eh,对CH4排放的影响.结果表明,不同的施肥处理,晚稻田CH4排放的季节变化和土壤Eh呈显著负相关,与土壤温度呈显著正相关,与水层深度相关不明显.  相似文献   

20.
Multiphoton excitation microscopy at 730 nm and 960 nm was used to image in vivo human skin autofluorescence from the surface to a depth of approximately 200 microm. The emission spectra and fluorescence lifetime images were obtained at selected locations near the surface (0-50 microm) and at deeper depths (100-150 microm) for both excitation wavelengths. Cell borders and cell nuclei were the prominent structures observed. The spectroscopic data suggest that reduced pyridine nucleotides, NAD(P)H, are the primary source of the skin autofluorescence at 730 nm excitation. With 960 nm excitation, a two-photon fluorescence emission at 520 nm indicates the presence of a variable, position-dependent intensity component of flavoprotein. A second fluorescence emission component, which starts at 425 nm, is observed with 960-nm excitation. Such fluorescence emission at wavelengths less than half the excitation wavelength suggests an excitation process involving three or more photons. This conjecture is further confirmed by the observation of the super-quadratic dependence of the fluorescence intensity on the excitation power. Further work is required to spectroscopically identify these emitting species. This study demonstrates the use of multiphoton excitation microscopy for functional imaging of the metabolic states of in vivo human skin cells.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号