首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Effect of positive airway pressure on capillary transit time in rabbit lung   总被引:1,自引:0,他引:1  
We used fluorescence videomicroscopy to measure the passage of fluorescent dye through the subpleural microcirculation of the lung. With the rabbit in the left lateral decubitus position, the subpleural microcirculation was viewed either through a transparent parietal pleural window located in the superior part of the chest or directly with the chest open. There was no physical contact with the chest or lung. The rabbit was anesthetized, paralyzed, and mechanically ventilated with 100% O2. The dye was injected into the right ventricle during a 2-min apneic period to eliminate lung movement due to ventilation. The video signal of the passage of the dye was analyzed frame by frame by use of digital image processing to compensate for cardiogenic oscillations of the lung surface. Gray scale levels of an arteriole and adjacent venule were measured every 1/30 s. Capillary transit time was determined from the difference between the concentration-weighted mean time values of the arteriolar and venular dye dilution curves. We studied the effect of airway pressure (0-20 cmH2O) on transit time. Cardiac output was measured at different airway pressures by the thermal dilution technique. Capillary transit time averaged 0.60 s at functional residual capacity. Right ventricular-to-arteriolar transit time was four times as large as the capillary transit time. An increase in airway pressure from 0-5 to 20 cmH2O resulted in a fourfold increase in both capillary and arterial transit times and a threefold decrease in cardiac output.  相似文献   

2.
At functional residual capacity, lung expansion is more uniform in the prone position than in the supine position. We examined the effect of positive airway pressure (Paw) on this position-dependent difference in lung expansion. In supine and prone rabbits postmortem, we measured alveolar size through dependent and nondependent pleural windows via videomicroscopy at Paw of 0 (functional residual capacity), 7, and 15 cmH2O. After the chest was opened, alveolar size was measured in the isolated lung at several transpulmonary pressures (Ptp) on lung deflation. Alveolar mean linear intercept (Lm) was measured from the video images taken in situ. This was compared with those measured in the isolated lung to determine Ptp in situ. In the supine position, the vertical Ptp gradient increased from 0.52 cmH2O/cm at 0 cmH2O Paw to 0.90 cmH2O/cm at 15 cmH2O Paw, while the vertical gradient in Lm decreased from 2.17 to 0.80 microns/cm. In the prone position, the vertical Ptp gradient increased from 0.06 cmH2O/cm at 0 cmH2O Paw to 0.35 cmH2O/cm at 15 cmH2O Paw, but there was no change in the vertical Lm gradient. In anesthetized paralyzed rabbits in supine and prone positions, we measured pleural liquid pressure directly at 0, 7, and 15 cmH2O Paw with dependent and nondependent rib capsules. Vertical Ptp gradients measured with rib capsules were similar to those estimated from the alveolar size measurements. Lung inflation during mechanical ventilation may reduce the vertical nonuniformities in lung expansion observed in the supine position, thereby improving gas exchange and the distribution of ventilation.  相似文献   

3.
To describe the flow characteristics of vessels open in zone 1, we perfused isolated rabbit lungs with Tyrode's solution containing 1% albumin, 4% dextran, and papaverine (0.05 mg/ml). Lungs were expanded by negative pleural pressure (Ppl) of -10, -15, -20, and -25 cmH2O. Pulmonary arterial (Ppa) and venous (Ppv) pressures were varied relative to alveolar pressure (PA = 0) and measured 5-10 mm inside the pleura (i) and outside (o) of the lungs. With Ppa(o) at -2.5 cmH2O, we constructed pressure-flow (P-Q) curves at each Ppl by lowering Ppv(o) until Q reached a maximum, indicating fully developed zone 1 choke flow. Maximum flows were negligible until Ppl fell below -10 cmH2O, then increased rapidly at Ppl of -15 and -20 cmH2O, and at Ppl of -25 cmH2O reached about 15 ml.min-1.kg body wt-1. The Ppv(o) at which flow became nearly constant depended on degree of lung inflation and was 5-8 cmH2O more positive than Ppl. As Ppv(o) was lowered below Ppa(o), Ppv(i) remained equal to Ppv(o) until Ppv(i) became fixed at a pressure 2-3 cmH2O more positive than Ppl. At this point the choke flow was therefore located in veins near the pleural boundary. No evidence of choke flow (only ohmic resistance) was seen in the intrapulmonary segment of the vessels remaining open in zone 1. With Ppv(o) held roughly at Ppl, Q could be stopped by lowering Ppa(o), at which time Ppa(i) was several cmH2O above Ppv(i), showing that intrapulmonary vessel closure had occurred.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

4.
In anesthetized mongrel dogs we measured the blood flow in the left phrenic artery (Qdi), using an electromagnetic flow probe, before and during supramaximal phrenic nerve stimulation (pacing). This was done at constant respiratory rate (24/min) but at three different stimulation frequencies at a duty cycle of 0.4 (20, 50, and 100 Hz) and at three different duty cycles at a stimulation frequency of 50 Hz (duty cycle = 0.2, 0.4, and 0.8). Qdi was unchanged during diaphragm contraction until transdiaphragmatic pressure (Pdi) was greater than approximately 11 cmH2O, whereafter it began to decrease, reaching zero at Pdi approximately 20 cmH2O. Thus, when Pdi was greater than 21 cmH2O, all flow occurred during relaxation. Qdi averaged over the entire respiratory cycle (Qt) was less at duty cycle = 0.8 than under the other conditions. This was because of decreasing length of relaxation phase rather than a difference of relaxation phase flow (Qr), which was maximal during all conditions of phrenic stimulation. During pacing-induced fatigue, Qt actually rose slightly as Pdi fell. This was due to an increase in contraction phase flow while Qr remained constant. The relationship between Qt and tension-time index was not unique but varied according to the different combinations of duty cycle and stimulus frequency.  相似文献   

5.
A method to measure the pressure-flow behavior of the interstitium around large pulmonary vessels is presented. Isolated rabbit lungs were degassed, and the air spaces and vasculature were inflated with a silicon rubber compound. After the rubber had hardened the caudal lobes were sliced into 1-cm-thick slabs. Two chambers were bonded to opposite sides of a slab enclosing a large blood vessel and were filled with saline containing 3 g/dl albumin. The flow through the interstitium surrounding the vessel was measured at a constant driving pressure of 5 cmH2O and at various mean interstitial pressures. Flow decreased with a reduction of mean interstitial pressure and reached a limiting minimum value at approximately -9 cmH2O. The pressure-flow behavior was analyzed under the assumptions that the interstitium is a porous material described by a single permeability constant that increases with hydration and that the expansion of the interstitium with interstitial pressure was due to the elastic response of the surrounding rubber compound. This resulted in an interstitial resistance (reciprocal of permeability constant) of 1.31 +/- 1.03 (SD) cmH2O.h.cm-2 and a ratio of interstitial cuff thickness to vessel radius of 0.022 +/- 0.007 (SD), n = 11. The phenomenon of flow limitation was demonstrated by holding the upstream pressure constant at 15 cmH2O and measuring the flow while the downstream pressure was reduced. The flow was limited at downstream pressures below -10 cmH2O.  相似文献   

6.
The growth rate and albumin concentration of interstitial fluid cuffs were measured in isolated rabbit lungs inflated with albumin solution (3 g/dl) to constant airway (Paw) and vascular pressures for up to 10 h. Cuff size was measured from images of frozen lung sections, and cuff albumin concentration (Cc) was measured from the fluorescence of Evans blue labeled albumin that entered the cuffs from the alveolar space. At 5-cmH2O Paw, cuff size peaked at 1 h and then decreased by 75% in 2 h. The decreased cuff size was consistent with an osmotic absorption into the albumin solution that filled the vascular and alveolar spaces. At 15-cmH2O Paw, cuff size peaked at 0.25 h and then remained constant. Cc rose continuously at both pressures, but was greater at the higher pressure. The increasing Cc with a constant cuff size was modeled as diffusion through epithelial pores. Initial Cc-to-airway albumin concentration ratio was 0.1 at 5-cmH2O Paw and increased to 0.3 at 15 cmH2O, a behavior that indicated an increased permeability with lung inflation. Estimated epithelial reflection coefficient was 0.9 and 0.7, and equivalent epithelial pore radii were 4.5 and 6.1 nm at 5- and 15-cmH2O Paw, respectively. The initial cuff growth occurred against an albumin colloid osmotic pressure gradient because a high interstitial resistance reduced the overall epithelial-interstitial reflection coefficient to the low value of the interstitium.  相似文献   

7.
We studied the bronchial arterial blood flow (Qbr) and bronchial vascular resistance (BVR) in sheep prepared with carotid-bronchial artery shunt. Nine adult sheep were anesthetized, and through a left thoracotomy a heparinized Teflon-tipped Silastic catheter was introduced into the bronchial artery. The other end of the catheter was brought out through the chest wall and through a neck incision was introduced into the carotid artery. A reservoir filled with warm heparinized blood was connected to this shunt. The height of blood column in the reservoir was kept constant at 150 cm by adding more blood. Qbr was measured, after interrupting the carotid-bronchial artery flow, by the changes in the reservoir volume. The bronchial arterial back pressure (Pbr) was measured through the shunt when both carotid-bronchial artery and reservoir Qbr had been temporarily interrupted. The mean Qbr was 34.1 +/- 2.9 (SE) ml/min, Pbr = 17.5 +/- 3.3 cmH2O, BVR = 3.9 +/- 0.5 cmH2O X ml-1 X min, mean pulmonary arterial pressure = 21.5 +/- 3.6 cmH2O, and pulmonary capillary wedge pressure (Ppcw) = 14.3 +/- 3.7 cmH2O. We further studied the effect of increased left atrial pressure on these parameters by inflating a balloon in the left atrium. The left atrial balloon inflation increased Ppcw to 25.3 +/- 3.1 cmH2O, Qbr decreased to 21.8 +/- 2.4 ml/min (P less than 0.05), and BVR increased to 5.5 +/- 1.0 cmH2O.ml-1.min (P less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

8.
This study measured transit time (TT) and attenuation of sound transmitted through six pairs of excised pig lungs. Single-frequency sounds (50-600 Hz) were applied to the tracheal lumen, and the transmitted signals were monitored on the tracheal and lung surface using microphones. The effect of varying intrapulmonary pressure (Pip) between 5 and 25 cmH(2)O on TT and sound attenuation was studied using both air and helium (He) to inflate the lungs. From 50 to approximately 200 Hz, TT decreased from 4.5 ms at 50 Hz to 1 ms at 200 Hz (at 25 cmH(2)O). Between approximately 200 and 600 Hz, TT was relatively constant (1.1 ms at upper and 1.5 ms at lower sites). Gas density had very little effect on TT (air-to-He ratio of approximately 1.2 at upper sites and approximately 1 at lower sites at 25 cmH(2)O). Pip had marked effects (depending on gas and site) on TT between 50 and 200 Hz but no effect at higher frequencies. Attenuation was frequency dependent between 50 and 600 Hz, varying between -10 and -35 dB with air and -2 and -28 dB with He. Pip also had strong influence on attenuation, with a maximum sensitivity of 1.14 (air) and 0.64 dB/cmH(2)O (He) at 200 Hz. At 25 cmH(2)O and 200 Hz, attenuation with air was about three times higher than with He. This suggests that sound transmission through lungs may not be dominated by parenchyma but by the airways. The linear relationship between increasing Pip and increasing attenuation, which was found to be between 50 and approximately 100 Hz, was inverted above approximately 100 Hz. We suggest that this change is due to the transition of the parenchymal model from open to closed cell. These results indicate that acoustic propagation characteristics are a function of the density of the transmission media and, hence, may be used to locate collapsed lung tissue noninvasively.  相似文献   

9.
These experiments examine the transfer of sucrose, urea, sodium, and albumin from blood to brain in new-born pigs exposed to an increase in ventilation pressure. We also studied the movement of urea and sodium from blood to cerebrospinal fluid (CSF). By use of a standard time-cycled pressure-limited infant respirator, mean airway pressure (Paw) was increased from approximately 3 to 17 cmH2O. Urea and albumin transfer into the brain were unchanged with increased Paw. Sodium transport decreased significantly in all brain regions, while sucrose transfer was increased in the cerebrum [transfer constant (Kin) = 3.5 +/- 0.04 vs. 9.9 +/- 1.0 cm3.g-1.s-1.10(6)] at the increased Paw. Transport of urea nd sodium from blood to CSF decreased to half of control values with increased Paw. Thus, in newborn pigs, increasing Paw selectively alters blood-to-brain transport. In addition, movement of tracers from blood to CSF was severely restricted, possibly by a decrease in CSF production. It appears likely that the increased cerebral venous pressure causes the observed changes in tracer transport. Such altered blood-to-brain transport could adversely affect neuronal function.  相似文献   

10.
We have determined the sites of hypoxic vasoconstriction in ferret lungs. Lungs of five 3- to 5-wk-old and five adult ferrets were isolated and perfused with blood. Blood flow was adjusted initially to keep pulmonary arterial pressure at 20 cmH2O and left atrial and airway pressures at 6 and 8 cmH2O, respectively (zone 3). Once adjusted, flow was kept constant throughout the experiment. In each lung, pressures were measured in subpleural 20- to 50-microns-diam arterioles and venules with the micropipette servo-nulling method during normoxia (PO2 approximately 100 Torr) and hypoxia (PO2 less than 50 Torr). In normoxic adult ferret lungs, approximately 40% of total vascular resistance was in arteries, approximately 40% was in microvessels, and approximately 20% was in veins. With hypoxia, the total arteriovenous pressure drop increased by 68%. Arterial and venous pressure drops increased by 92 and 132%, respectively, with no change in microvascular pressure drop. In 3- to 5-wk-old ferret lungs, the vascular pressure profile during normoxia and the response to hypoxia were similar to those in adult lungs. We conclude that, in ferret lungs, arterial and venous resistances increase equally during hypoxia, resulting in increased microvascular pressures for fluid filtration.  相似文献   

11.
In 10 anesthetized, paralyzed, supine dogs, arterial blood gases and CO2 production (VCO2) were measured after 10-min runs of high-frequency ventilation (HFV) at three levels of mean airway pressure (Paw) (0, 5, and 10 cmH2O). HFV was delivered at frequencies (f) of 3, 6, and 9 Hz with a ventilator that generated known tidal volumes (VT) independent of respiratory system impedance. At each f, VT was adjusted at Paw of 0 cmH2O to obtain a eucapnia. As Paw was increased to 5 and 10 cmH2O, arterial PCO2 (PaCO2) increased and arterial PO2 (PaO2) decreased monotonically and significantly. The effect of Paw on PaCO2 and PaO2 was the same at 3, 6, and 9 Hz. Alveolar ventilation (VA), calculated from VCO2 and PaCO2, significantly decreased by 22.7 +/- 2.6 and 40.1 +/- 2.6% after Paw was increased to 5 and 10 cmH2O, respectively. By taking into account the changes in anatomic dead space (VD) with lung volume, VA at different levels of Paw fits the gas transport relationship for HFV derived previously: VA = 0.13 (VT/VD)1.2 VTf (J. Appl. Physiol. 60: 1025-1030, 1986). We conclude that increasing Paw and lung volume significantly decreases gas transport during HFV and that this effect is due to the concomitant increase of the volume of conducting airways.  相似文献   

12.
To confirm the regional differences in vascular pressure vs. flow properties of lung regions that have been documented in zone 2 conditions [pulmonary venous pressure (Ppv) less than alveolar pressure], regional distending pressure vs. flow curves in zone 3 were generated by use of isolated blood-perfused dog lungs (3 right and 5 left lungs). Each lung was kept inflated at constant inflation pressure (approximately 50% of full inflation volume) while radioactively labeled microspheres were injected at different settings of Ppv. To achieve maximal vascular distension, Ppv was increased to approximately 30 cmH2O above alveolar pressure for the first injection. Subsequent injections were made at successively lower Ppv's. The difference between pulmonary arterial pressure and Ppv was kept constant for all injections. As was found in zone 2 conditions, there were differences in the regional distending pressure vs. flow curves among lung regions. To document the regional variability in the curves, the distribution of flow at a regional Ppv of 30 cmH2O above alveolar pressure was analyzed. There was a statistically significant linear gradient in this flow distribution from dorsal to ventral regions of the lungs but no consistent gradient in the caudad to cephalad direction. These results indicate that, even in near-maximally distended vessels, the dorsal regions of isolated perfused dog lungs have lower intrinsic vascular resistance compared with ventral regions.  相似文献   

13.
We studied collateral flow resistance in exsanguinated, excised lower lobes and accessory lobes of dog and horse lungs, respectively. A double lumen catheter obstructed a peripheral airway isolating a segment of the lobe. Oxygen flowed into the segment via a rotameter which measured flow (Vcoll) while the inner catheter recorded segment pressure (Ps). Gas delivered into the segment flowed out via collateral channels. Collateral flow resistance was calculated as (Ps - PL)/Vcoll, where PL = static transpulmonary pressure. Rcoll at PL = 20, 10, and 5 cm H2O averaged 0.24, 1.25, and 2.65 cmH2O.ml-1.s, respectively, in the dog, and 4.53, 6.00, and 12.62 cmH2O.ml-1.s in the horse. At a given PL, Rcoll measured during inflation. At constant PL, Rcoll increased with time at PL = 5 and 10 cmH2O, but was not time dependent at PL = 20 cmH2O. At constant PL, Rcoll increased at Vcoll increased. We conclude Rcoll is greater in horses than in dogs and is a function of PL, Ps - PL, and lung volume history in both species.  相似文献   

14.
The purpose of this study was to determine the sites of hypoxic vasoconstriction in lungs of newborn rabbits. We isolated and perfused with blood the lungs from 19 rabbit pups, 7-23 days old. We maintained blood flow constant, continuously monitored pulmonary arterial and left atrial pressures, and alternated ventilation of the lungs with 95% O2-5% CO2 (control), and 95% N2-5% CO2 (hypoxia). Using micropipettes and a servonulling device, we measured pressures in 20-60-micron-diam subpleural arterioles and venules during control and hypoxic conditions. We inflated the lungs to a constant airway pressure of 5-7 cmH2O and kept left atrial pressure greater than airway pressure (zone 3) during micropuncture. In eight lungs we measured microvascular pressures first during control and then during hypoxia. We reversed this order in four lungs. In seven lungs we measured microvascular pressures only during hypoxia. We found a significant increase in pulmonary arterial pressure with no change in microvascular pressures. These results indicate that the site of hypoxic vasoconstriction in lungs of newborn rabbits is arteries greater than 60 micron in diameter.  相似文献   

15.
We examined the effect of the air interface on pulmonary vascular resistance (PVR) in zones 1, 2, and 3 by comparing pressure-flow data of air- and liquid-filled isolated rabbit lungs. Lungs were perfused with Tyrode's solution osmotically balanced with 1% albumin and 4% dextran and containing the vasodilator papaverine (0.05 mg/ml). Lung volume was varied by negative pleural pressure form 0 to -25 cmH2O. Pulmonary artery (Ppa) and venous (Ppv) pressures were fixed at various levels relative to the lung base. Alveolar pressure (PA) was always zero, and perfusate flow was measured continuously. In zone 1 Ppa was -2.5 cmH2O and Ppv was -15 cmH2O. In zone 2 Ppa was 10 cmH2O and Ppv was -5 cmH2O. In zone 3 Ppa was 15 cmH2O and Ppv was 8 cmH2O. We found that in zone 1 the interface was essential for perfusion, but in zones 2 and 3 it had much lesser effects. In general, PVR depended almost uniquely (i.e., with small hysteresis) on transpulmonary pressure, whereas a large hysteresis existed between PVR and lung volume. PVR was high in collapsed and especially in atelectatic lungs, fell sharply with moderate inflation, and within the ranges of vascular pressure studied did not rise again toward total lung capacity. These results suggest that in zone 1 the interface maintains the patency of some alveolar vessels, probably in corners. The majority of alveolar septal vessels appears to be exposed directly to PA in zones 2 and 3, because at equal transpulmonary pressure the PVR is similar in the presence or absence of an interface.  相似文献   

16.
The effects of positive end-expiratory pressure (PEEP) on the pulmonary circulation were studied in 14 intact anesthetized dogs with oleic acid (OA) lung injury. Transmural (tm) mean pulmonary arterial pressure (Ppa)/cardiac index (Q) plots with transmural left atrial pressure (Pla) kept constant were constructed in seven dogs, and Ppa(tm)/PEEP plots with Q and Pla(tm) kept constant were constructed in seven other dogs. Q was manipulated by using a femoral arteriovenous bypass and a balloon catheter inserted in the inferior vena cava. Pla was manipulated using a balloon catheter placed by thoracotomy in the left atrium. Ppa(tm)/Q plots were essentially linear. Before OA, the linearly extrapolated pressure intercept of the Ppa(tm)/Q relationship approximated Pla(tm). OA (0.09 ml/kg into the right atrium) produced a parallel shift of the Ppa(tm)/Q relationship to higher pressures; i.e., the extrapolated pressure intercept increased while the slope was not modified. After OA, 4 Torr PEEP (5.4 cmH2O) had no effect on the Ppa(tm)/Q relationship and 10 Torr PEEP (13.6 cmH2O) produced a slight, not significant, upward shift of this relationship. Changing PEEP from 0 to 12 Torr (16.3 cmH2O) at constant Q before OA led to an almost linear increase of Ppa(tm) from 14 +/- 1 to 19 +/- 1 mmHg. After OA, Ppa(tm) increased at 0 Torr PEEP but changing PEEP from 0 to 12 Torr did not significantly affect Ppa(tm), which increased from 19 +/- 1 to 20 +/- 1 mmHg. These data suggest that moderate levels of PEEP minimally aggravate the pulmonary hypertension secondary to OA lung injury.  相似文献   

17.
18.
To determine the effect of lung inflation and left atrial pressure on the hydrostatic pressure gradient for fluid flux across 20- to 60-microns-diam venules, we isolated and perfused the lungs from newborn rabbits, 7-14 days old. We used the micropuncture technique to measure venular pressures in some lungs and perivenular interstitial pressures in other lungs. For all lungs, we first measured venular or interstitial pressures at a constant airway pressure of 5 or 15 cmH2O with left atrial pressure greater than airway pressure (zone 3). For most lungs, we continued to measure venular or interstitial pressures as we lowered left atrial pressure below airway pressure (zone 2). Next, we inflated some lungs to whichever airway pressure had not been previously used, either 5 or 15 cmH2O, and repeated venular or interstitial pressures under one or both zonal conditions. We found that at constant blood flow a reduction of left atrial pressure below airway pressure always resulted in a reduction in venular pressure at both 5 and 15 cmH2O airway pressures. This suggests that the site of flow limitation in zone 2 was located upstream of venules. When left atrial pressure was constant relative to airway pressure, the transvascular gradient (venular-interstitial pressures) was greater at 15 cmH2O airway pressure than at 5 cmH2O airway pressure. These findings suggest that in newborn lungs edema formation would increase at high airway pressures only if left atrial pressure is elevated above airway pressure to maintain zone 3 conditions.  相似文献   

19.
The effects of alpha-naphthylthiourea (ANTU) on lung microvascular permeability to plasma proteins were studied in anesthetized open-chest dogs. Lymph flow (Jv) was recorded, and total protein in plasma and lymph was analyzed after cannulating a small prenodal lung lymphatic. The protocol involved four experimental periods. Period 1. During this base-line period the preparation stabilized and steady states were reached in Jv, lymph total protein, pulmonary arterial pressure (Ppa), and left atrial pressure (Pla). Period 2. Pla was increased to approximately 20 cmH2O and maintained at that level until Jv and protein measurements attained a new steady state. Period 3. After Pla was lowered to control levels, ANTU (5 mg/kg body wt) was infused intravenously and parameters were measured for 3 h. Period 4 Pla was again raised to the pre-ANTU levels of period 2 and maintained for an additional 2-3 h. The lymphatic total protein clearance increased 8.6-fold for an equivalent increase in pulmonary capillary pressure after ANTU. Vascular permeability was assessed by estimating the osmotic reflection coefficient (sigma d) for total protein at the pulmonary capillary membrane. Sigma d decreased from 0.65 to 0.40 following ANTU. From plasma protein fractions in four experiments, equivalent pore radii for the capillary membrane of 95 and 280 A were calculated after ANTU compared with 80 and 200 A for normal lung capillaries. In addition, extravascular lung water increased from 3.8 +/- 0.16 to 5.87 +/- 0.25 following ANTU and to 7.55 +/- 0.55 (g/g blood-free dry wt) when Pla was elevated with ANTU. The experimental design allowed quantitative assessment of the vascular permeability increase after ANTU by use of lymph protein fluxes that had minimal errors due to changes in surface area or lymph contamination from nonpulmonary structures.  相似文献   

20.
We studied the effect of mean airway pressure (Paw) on gas exchange during high-frequency oscillatory ventilation in 14 adult rabbits before and after pulmonary saline lavage. Sinusoidal volume changes were delivered through a tracheostomy at 16 Hz, a tidal volume of 1 or 2 ml/kg, and inspired O2 fraction of 0.5. Arterial PO2 and PCO2 (PaO2, PaCO2), lung volume change, and venous admixture were measured at Paw from 5 to 25 cmH2O after either deflation from total lung capacity or inflation from relaxation volume (Vr). The rabbits were lavaged with saline until PaO2 was less than 70 Torr, and all measurements were repeated. Lung volume change was measured in a pressure plethysmograph. Raising Paw from 5 to 25 cmH2O increased lung volume by 48-50 ml above Vr in both healthy and lavaged rabbits. Before lavage, PaO2 was relatively insensitive to changes in Paw, but after lavage PaO2 increased with Paw from 42.8 +/- 7.8 to 137.3 +/- 18.3 (SE) Torr (P less than 0.001). PaCO2 was insensitive to Paw change before and after lavage. At each Paw after lavage, lung volume was larger, venous admixture smaller, and PaO2 higher after deflation from total lung capacity than after inflation from Vr. This study shows that the effect of increased Paw on PaO2 is mediated through an increase in lung volume. In saline-lavaged lungs, equal distending pressures do not necessarily imply equal lung volumes and thus do not imply equal PaO2.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏