首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We evaluated the use of HPLC multi-channel coulometric electrochemical detection (HPLC-ECD) for the routine measurement of phytochemicals by analyzing standards and urine samples. Compounds were separated chromatographically and electrochemically with high sensitivity (10 ng/ml of isoflavones in urine). HPLC-ECD will enable better investigation into the relationship between lifestyle and the effects of phytochemicals on humans.  相似文献   

2.
A method for the detection of ascorbic acid using high-performance liquid chromatography with coulometric electrochemical detection and a technique for stabilization of the vitamin are described. Since less than 1 pmol of ascorbic acid can be detected, this assay provides significantly greater sensitivity than nearly all of the currently available procedures. Stabilization of 10 pmol or less of ascorbic acid at room temperature for up to 4 h and for several weeks at -70 degrees C facilitates storage of a large number of samples and measurement of ascorbic acid using an automated sampling device. This method was used to quantitate the amounts of ascorbic acid in human polymorphonuclear leukocytes and bovine adrenomedullary chromaffin granules. The calculated concentrations found for human neutrophils (1.35 mM) and bovine chromaffin granules (10.0 mM) are in agreement with previously published data. The assay is suitable for the determination of ascorbic acid in biological samples where only a small amount of tissue is available or very low amounts of ascorbic acid are found. This method is the first application of coulometric electrochemical detection to ascorbic acid HPLC analysis.  相似文献   

3.
The antioxidants, 2-tert.-butyl-4-methoxyphenol (BHA) and its oxidative peroxidation product 2,2′-dihydroxy-3,3′-di-tert.-butyl-5,5′-dimethoxybiphenyl (di-BHA), 3,5-di-tert.-butyl-4-hydroxytoluene (BHT) and propyl gallate, were measured in plasma and tissue homogenates by HPLC and electrochemical detection, with a sensitivity down to 0.2 (BHA), 0.1 (di-BHA), 0.4 (BHT) and 1 (propyl gallate) ng ml−1 of plasma or tissue homogenate. The data demonstrate that in man, at the current level of exposure to dietary antioxidants, significant amounts of BHA, BHT and propyl gallate are accumulated in the omentum. Furthermore, they provide the first evidence that the peroxidase-catalysed oxidation of BHA is operative in man.  相似文献   

4.
A highly sensitive high-performance liquid chromatographic method with electrochemical detection (HPLC-ED) was developed for the determination of isoflavones. Electrochemical behaviour of daidzein and genistein was studied on carbon paste electrode (CPE) by adsorptive transfer stripping square wave voltammetry. The obtained electrochemical results were used for the development of HPLC-ED method. Furthermore, isoflavones were separated on an Atlantis dC18 column using a mobile phase consisting of acetonitrile (solvent A) and 0.15M acetate buffer of pH 5.5 (solvent B) at a flow rate 0.4 mL/min. A linear gradient profile (solvent B) was at 0-2 min 87%; 22 min 60%; 27 min 50%; 31 min 45%; 47 min 87%. Full scan of multi-channel coulometric detection was tested and optimal potential at 450 mV was chosen for our purposes. Calibration curves were linear (daidzein R(2) = 0.9993 and genistein R(2) = 0.9987). The detection limit for daidzein/genistein was 480/394 pg/mL (1.8/1.5 nM) and per column 2.4/1.9 pg. Isoflavones extracted from soybean products (farina, meat, milk) by the accelerated solvent extraction (ASE) procedure and isoflavones present in human urine were determined by the HPLC-ED method.  相似文献   

5.
Cysteamine is currently used to treat children with the inherited disorder nephropathic cystinosis. A method for the quantitative determination of this aminothiol in human plasma is presented. Whole plasma was reduced with sodium borohydride to convert disulfides to thiols. Cysteamine was then separated by high-performance liquid chromatography and detected electrochemically. The recovery of standard cysteamine added to plasma was 96.6 +/- 1.9%. In a patient with cystinosis, an oral dose of cysteamine was absorbed rapidly, with plasma cysteamine reaching a maximum of 56 microM 1 h after the dose. By 1.8 h the plasma cysteamine concentration had decreased to one-half the maximum value.  相似文献   

6.
A method for simultaneous detection and quantification is presented to determine the presence of isoflavones and bisphenol A in a biological sample. A coulometric array detector was used with reversed-phase high-performance liquid chromatography (HPLC). Daidzein (1), glycitein (2), genistein (3) and their glucoside conjugates, daidzin (4), glycitin (5) and genistin (6), were measured as phytochemicals. Also assayed here was equol (7), a metabolite from compound 1, and bisphenol A (8), an industrial chemical that acts as an endocrine disrupter. All chemicals were simultaneously detected by using a 600-mV single detection voltage with high efficacy. A mixture of 1, 3 and 8 was orally administered to rats, and the levels of these three chemicals in the serum were clearly increased after a 4 kU beta-glucuronidase treatment. The levels of compounds 1 and 3 in the serum were detected at 1665 and 2040 ng/ml, while 8 was at a low level of 417 ng/ml. Compound 7 in the serum was not detected until after enzymatic hydrolysis (72 ng/ml). These results suggest that this analytical method would be useful for metabolic and pharmacokinetic studies on isoflavones and bisphenol A.  相似文献   

7.
Naloxone, the analyte and the internal standard, sumatriptan, are extracted from plasma using solid-phase extraction columns. Chromatography and detection are performed using isocratic reversed-phase high-performance liquid chromatography (HPLC) with coulometric end-point detection. The standard curve was linear over the range 0–50 ng/ml of naloxone in plasma. The reproducibility, the coefficient of variation (C.V.) of the method over the range of the standard curve was 6.2–11.2%. The recovery averaged 90.4±8.9%. A plasma profile following i.v. administration of naloxone in one normal healthy volunteer is presented.  相似文献   

8.
High performance liquid chromatography with coulometric electrochemical detection has been used to achieve simultaneous determination of norepinephrine, epinephrine, 5-hydroxytryptophan, normetanephrine, dopamine, metanephrine, 3,4-dihydroxyphenylacetic acid, N-acetyldopamine, tyramine, tryptophan, 5-hydroxyindoleacetic acid, 5-hydroxytryptamine, N-acetyl-5-hydroxytryptamine, homovanillic acid, tyrosine, p-octopamine, N-acetyl-p-octopamine, and p-synephrine. The procedure has been applied to study monoamine degradation in the insect brain and to demonstrate that N-acetylation rather than oxidative deamination is the primary route of monoamine catabolism in insects.  相似文献   

9.
10.
A simple, fast and sensitive HPLC method employing dual-channel coulometric detection for the determination of repaglinide in human plasma is presented. The assay involved extraction of repaglinide by ethyl acetate and isocratic reversed-phase liquid chromatography with dual-channel coulometric detection. The mobile phase composition was 50mM disodium hydrogen phosphate/acetonitrile (60:40, v/v), pH of the mobile phase 7.5 set up with phosphoric acid. For all analyses, the first cell working potential was +380mV, the second was +750mV (vs. Pd/H(2)). Calibration curve was linear over the concentration range of 5-500nmolL(-1). Rosiglitazone was used as an internal standard. The limit of detection (LOD) was established at 2.8nmolL(-1), and the lower limit of quantification (LLOQ) at 8.5nmolL(-1). The developed method was applied to human plasma samples spiked with repaglinide at therapeutical concentrations. It was confirmed that the method is suitable for pharmacokinetic studies or therapeutic monitoring.  相似文献   

11.
An HPLC method is described for the determination of iodide in serum and urine using ion-pair chromatography with coulometric detection. After adding hexadecyltrimethylammonium chloride, the ions pairs formed with the iodide in the sample are extracted using an organic solvent. The solvent is then evaporated and the dry residue obtained is mixed with an appropriate volume of mobile phase so as to concentrate the sample prior to injection into the chromatograph. For a sample of 0.5 ml of serum, the method features a limit of detection (signal-to-noise ratio of 3) of 0.2 μgl−1, sufficient to be applied in paediatric assays for the diagnosis of both iodide deficiency and excess.  相似文献   

12.
A highly sensitive and selective method for determining 8-oxoguanine in plasma and urine was developed by high-performance liquid chromatography with electrochemical detection. The compound was separated by gradient elution on a C18 reversed-phase column with a mobile phase of acetonitrile and 0.1 M sodium acetate, pH 5.2. 8-Hydroxy-2′-deoxyguanosine was used as internal standard. 8-Oxoguanine was detected electrochemically by setting the potential to +300 mV vs. Pd reference. The sensitivity of the assay was 22 ng/ml with a signal-to-noise ratio of 7:1. The within-day relative standard deviations for 8-oxoguanine quality control samples with concentrations of 3340, 1340 and 84 ng/ml were 3.6, 4.3 and 5.7% for plasma, and 4.1, 4.6 and 6.2% for urine, respectively. The day-to-day relative standard deviations for the same samples were 3.8, 6.8 and 7.1% for plasma, and 3.9, 7.0 and 7.9% for urine, respectively. The method is designed to study the pharmacokinetics and metabolic fate of O6-benzylguanine in a phase I clinical trial. Previously, O6-benzyl-8-oxoguanine was identified as the primary metabolite of O6-benzylguanine in humans. We now demonstrate that 8-oxoguanine is a further metabolite of O6-benzylguanine.  相似文献   

13.
A rapid, selective and sensitive method for the simultaneous determination of chlorpromazine and levomepromazine in human plasma and urine has been developed using high-performance liquid chromatography with electrochemical detection.The unchanged drugs and internal standard extracted from plasma and urine were separated by reversed-phase high-performance liquid chromatography. The influence of acetonitrile concentration and of the pH of the mobile phase were investigated. The detection limits were 100 pg for chlorpromazine and for levomepromazine. In comparison with three other detection systems this was found to be the most sensitive method.This method was successfully applied to the simultaneous determination of chlorpromazine and levomepromazine in human plasma and urine for pharmacokinetic studies.  相似文献   

14.
The presence of mammalian lignans, mainly enterolactone, in human plasma has been related to lower incidence of certain cancers and cardiovascular disease. The plant lignans secoisolariciresinol and matairesinol have been reported to be precursors of mammalian lignans, but recently other plant lignans relatively abundant in the diet have also been identified as precursors. To evaluate the importance and contribution of these new dietary precursors to the mammalian lignan formation in vivo, metabolic studies in human subjects must be carried out. For this purpose a method based on high-performance liquid chromatography using coulometric electrode array detection for the simultaneous determination of nine plant lignans and two mammalian lignans in human plasma was developed, validated, and shown to fulfill the reliability criteria.  相似文献   

15.
Carvedilol is a beta/alpha1-adrenoceptor blocker. A sensitive method for measuring plasma levels of carvedilol in human administrated low doses is needed since its plasma concentration is low. We measured carvedilol and carvedilol M21-aglycon using high-performance liquid chromatography (HPLC) with electrochemical detection. The amperometric detector was operated at 930 mV versus Ag/AgCl. Mean coefficients of variation (n = 5) for carvedilol and M21-aglycon were 4.0 and 7.7% (intra) and 6.1 and 6.7% (inter), respectively. The lower limit of quantification for each analyte was 0.10 ng/ml (signal-to-noise ratio = 3). This lower limit of quantification for carvedilol was sufficient for clinical use.  相似文献   

16.
The title determination was conducted by HPLC with electrochemical detection using an ODS column and a mobile phase of acetonitrile: 0.1 M phosphate buffer (pH 2.5) (15:85, v/v). The eight catechins, gallocatechin (GC), epigallocatechin (EGC), catechin (C), epicatechin (EC), epigallocatechin gallate (EGCg), gallocatechin gallate (GCg), epicatechin gallate (ECg), and catechin gallate (Cg), were detected at 0.6 V vs Ag/AgCl. Good linear relationships between current and amount were noted for 0.5-250 pmol of each catechin, with a correlation coefficient of 0.999 in each case. The detection limit for any one was 0.5 pmol (signal to noise ratio, S/N = 3). After the ingestion of 340 ml canned green tea, GC, EGC, C, and EC, mostly in conjugated form, were determined in urine samples. Conjugated catechins were hydrolyzed by enzymes using sulfatase and beta-glucuronidase. The time courses of the above four catechins showed a maxima at 1-3 h after tea ingestion. (+), (-)-EC and (+), (-)-C were present in canned tea.  相似文献   

17.
18.
Metabolic activation in the disposition of 3,4-methylenedioxymethamphetamine (MDMA, "ecstasy") has been implicated in some of its pharmacological and toxicological effects, with the major metabolite 3,4-dihydroxymethamphetamine (HHMA) as a putative toxicant through the formation of thioether adducts. We describe the first validated method for HHMA determination based on acid hydrolysis of plasma and urine samples, further extraction by a solid-phase strong cation-exchange resin (SCX, benzenesulfonic acid), and analysis of extracts by high-performance liquid chromatography with electrochemical detection. The chromatographic separation was performed in an n-butyl-silane (C4) column and the mobile phase was a mixture of 0.1 M sodium acetate containing 0.1 M 1-octanesulphonic acid and 4 mM EDTA (pH 3.1) and acetonitrile (82:18, v/v). Compounds were monitored with an electrochemical cell (working potentials 1 and 2, +0.05 and +0.35 V, respectively, gain 60 microA). A mobile phase conditioning cell with a potential set at +0.40 V was connected between the pumping system and the injector. Calibration curves were linear within the working concentration ranges of 50-1000 microg/L for urine and plasma. Limits of detection and quantification were 10.5 and 31.8 microg/L for urine and 9.2 and 28.2 microg/L for plasma. Recoveries for HHMA and DHBA (3,4-dihydroxybenzylamine, internal standard) were close to 50% for both biological matrices. Intermediate precision and inter-day accuracy were within 3.9-6.5% and 7.4-15.3% for urine and 5.0-10.8% and 9.2-13.4% for plasma.  相似文献   

19.
Alkylresorcinols (AR) are amphiphilic compounds present at high concentrations in the outer parts of wheat and rye kernels. Due to their specificity to whole grain and bran products of these cereals, AR and their metabolites have been proposed as biomarkers for intake of such foods. Two alkylresorcinol metabolites, 3,5-dihydroxybenzoic acid (DHBA) and 3-(3,5-dihydroxyphenyl)-1-propanoic acid (DHPPA), have previously been quantified in human urine using two different methodologies: high-performance liquid chromatography coupled to a coulometric electrode array detector (HPLC-CEAD) and gas chromatography in combination with mass spectrometry (GC-MS). In this study, these two methodologies were compared by analysing 114 urine samples from free-living Swedish subjects consuming their habitual diet. Data were evaluated by graphical investigation of difference-plots and statistical inference of agreement was assessed by weighted Deming regression analysis. The median DHBA concentrations were 11 μM (GC-MS) and 13 μM (HPLC-CEAD), respectively. Both difference-plot and regression analysis showed a small but statistically significant additive bias, with HPLC-CEAD resulting in a slightly higher DHBA concentration than GC-MS. The median concentration of DHPPA was 18 μM for both methods. Examination of the difference-plot of DHPPA did not indicate any systematic difference between the methods, but regression analysis showed small but statistically significant constant and proportional biases. The conclusion was that the two methodologies are equally suitable for analysis of alkylresorcinol metabolites in human urine and that any small systematic differences observed are most likely of limited practical importance.  相似文献   

20.
A high-performance liquid chromatographic method for the determination of trimethoprim metabolites in pig urine was developed. The metabolites — glucuronic acid and sulphuric acid conjugates of phenolic metabolites formed by demethylation of trimethoprim — were quantitated after treatment of urine with β-glucuronidase (Escherichia coli). The sulphuric acid conjugate was not susceptible to enzymatic hydrolysis and was therefore assayed as the conjugate by use of ion-pair chromatography on the reversed-phase column. In order to find suitable conditions for enzymatic hydrolysis of the glucoronides, the conjugates were obtained by gel chromatography of urine from a [14C]trimethoprim-treated pig.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号