首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Individuals with spastic cerebral palsy (CP) typically experience muscle weakness. The mechanisms responsible for muscle weakness in spastic CP are complex and may be influenced by the intrinsic mechanical properties of the muscle and tendon. The purpose of this study was to investigate the medial gastrocnemius (MG) muscle fascicle active torque-length and Achilles tendon properties in young adults with spastic CP. Nine relatively high functioning young adults with spastic CP (GMFCS I, 17±2 years) and 10 typically developing individuals (18±2 years) participated in the study. Active MG torque-length and Achilles tendon properties were assessed under controlled conditions on a dynamometer. EMG was recorded from leg muscles and ultrasound was used to measure MG fascicle length and Achilles tendon length during maximal isometric contractions at five ankle angles throughout the available range of motion and during passive rotations imposed by the dynamometer. Compared to the typically developing group, the spastic CP group had 33% lower active ankle plantarflexion torque across the available range of ankle joint motion, partially explained by 37% smaller MG muscle and 4% greater antagonistic co-contraction. The Achilles tendon slack length was also 10% longer in the spastic CP group. This study confirms young adults with mild spastic CP have altered muscle–tendon mechanical properties. The adaptation of a longer Achilles tendon may facilitate a greater storage and recovery of elastic energy and partially compensate for decreased force and work production by the small muscles of the triceps surae during activities such as locomotion.  相似文献   

2.
The purposes of this study were to examine (a) whether the morphological properties of the muscle gastrocnemius medialis (GM) contribute to the known enhanced muscle fatigue resistance during submaximal sustained isometric plantar flexion contraction of old compared to young adults and (b) whether a submaximal fatiguing contraction differently affects the mechanical properties of the GM tendon and aponeurosis of old and young adults. Fourteen old and 12 young male subjects performed maximal voluntary isometric plantar flexions (MVC) on a dynamometer before and after a submaximal fatiguing task (40% MVC). Moments and EMG signals from the gastrocnemius medialis and lateralis, soleus and tibialis anterior muscles were measured. The elongation of the GM tendon and aponeurosis and the morphological properties of its contractile element were examined by means of ultrasonography. The old adults showed lower maximal ankle joint moment, stiffness and fascicle length in both tested conditions. The submaximal fatiguing contraction did not affect the force-strain relationship of the GM tendon and aponeurosis of either young or old adults. The time to task failure was longer for the old adults and was strongly correlated with the fascicle length (r(2)=0.50, P<0.001). This provides evidence on that the lower ratio of the active muscle volume to muscle force for the old adults might be an additional mechanism contributing to the known age related increase in muscle fatigue resistance.  相似文献   

3.
The present study examined the reliability and validity of in vivo vastus lateralis (VL) fascicle length (L(f)) assessment by extended field-of-view ultrasonography (EFOV US). Intraexperimenter and intersession reliability of EFOV US were tested. Further, L(f) measured from EFOV US images were compared to L(f) measured from static US images (6-cm FOV) where out-of-field fascicle portions were trigonometrically estimated (linear extrapolation). Finally, spatial accuracy of the EFOV technique was assessed by comparing L(f) measured on swine VL by EFOV US to actual measurements from digital photographs. The difference between repeated VL L(f) measurements by the same experimenter was 2.1 ± 1.7% with an intraclass correlation (ICC) of 0.99 [95% confidence interval (CI) = 0.95-1.00]. In terms of intersession reliability, no difference (P = 0.48) was observed between L(f) measured on two different occasions, with ICC = 0.95 (CI = 0.80-0.99). The average absolute difference between L(f) measured by EFOV US and using linear extrapolation was 12.6 ± 8.1% [ICC = 0.76 (CI = -0.20-0.94)]; EFOV L(f) was always longer than extrapolated L(f). The relative error of measurement between L(f) measured by EFOV US and by dissective assessment (digital photographs) in isolated swine VL was 0.84% ± 2.6% with an ICC of 0.99 (CI = 0.94-1.00). These results show that EFOV US is a reliable and valid method for the measurement of long muscle fascicle in vivo. Thus EFOV US analysis was proven more accurate for the assessment of skeletal muscle fascicle length than conventional extrapolation methods.  相似文献   

4.
The purposes of this study were: (a) to quantify the influence of passive ankle and knee joint angular displacement on the estimated mechanical and architectural properties of the gastrocnemius medialis (GM) muscle-tendon unit, and (b) to determine the strain distribution of separate structures (tendon, aponeurosis and fascicle) during passive lengthening of the GM muscle-tendon unit at rest. Ten male subjects participated in the study. The passive ankle and knee joint movements were performed on an isokinetic dynamometer. The kinematics of the left leg were recorded using the Vicon 624 system with 8 cameras. Two ultrasound probes were used to examine the elongation of the tendon, the aponeurosis, the fascicles and the angle of pennation of the GM. To calculate the elongation of the GM muscle-tendon unit the Achilles tendon path was reconstructed using a series of small reflective markers. The results show that the passive ankle joint angular displacement has a considerable influence on the elongation of the tendinous and architectural structures of the GM muscle-tendon unit. In contrast, the influence of knee joint angular displacement on the GM fascicle length and pennation angle becomes relevant only at knee angles greater than 144 degrees . The contribution of the tendon to the elongation of the GM muscle-tendon unit at rest is relevant because of its greater resting length in comparison to the resting length of the GM fascicles. The results indicate the existence of slackness in the inactive GM muscle-tendon unit between 121 degrees and 107 degrees ankle angle and between 65 degrees and 144 degrees knee angle.  相似文献   

5.
The present study investigated the mechanical properties of tendon fascicles from the anterior and posterior human patellar tendon. Collagen fascicles from the anterior and posterior human patellar tendon in healthy young men (mean +/- SD, 29.0 +/- 4.6 yr, n = 6) were tested in a mechanical rig. A stereoscopic microscope equipped with a digital camera recorded elongation. The fascicles were preconditioned five cycles before the failure test based on pilot data on rat tendon fascicle. Human fascicle length increased with repeated cycles (P < 0.05); cycle 5 differed from cycle 1 (P < 0.05), but not cycles 2-4. Peak stress and yield stress were greater for anterior (76.0 +/- 9.5 and 56.6 +/- 10.4 MPa, respectively) than posterior fascicles (38.5 +/- 3.9 and 31.6 +/- 2.9 MPa, respectively), P < 0.05, while yield strain was similar (anterior 6.8 +/- 1.0%, posterior 8.7 +/- 1.4%). Tangent modulus was greater for the anterior (1,231 +/- 188 MPa) than the posterior (583 +/- 122 MPa) fascicles, P < 0.05. In conclusion, tendon fascicles from the anterior portion of the human patellar tendon in young men displayed considerably greater peak and yield stress and tangent modulus compared with the posterior portion of the tendon, indicating region-specific material properties.  相似文献   

6.
The purpose of this study was to quantify the influence of inevitable ankle joint motion during an isometric contraction on the measured change of the gastrocnemius medialis muscle (GM) architecture in vivo during the loading and the unloading phase. Sitting on a dynamometer subjects performed isometric maximal voluntary contractions as well as contractions induced by electrostimulation. Synchronous joint angular motion, plantarflexion moment, foot’s centre of pressure and real-time ultrasonography of muscle architecture changes of the GM were obtained. During the contraction the ankle joint position altered and significantly affected the change in muscle architecture. At maximal tendon force (1094 ± 323 N), the measured fascicle length overestimated the change in fascicle length due to the tendon force by 1.53 cm, while the measured pennation angle overestimated the change in pennation angle due to the tendon force by 5.5°. At the same tendon force the measured fascicle length and pennation angle were significantly different between loading and unloading conditions. After correcting the values for the change in ankle joint angle no differences between the loading and the unloading phase at the same tendon force were found. Concerning the estimation of GM fascicle length–force and pennation angle–force curves during the loading and unloading phase of an isometric contraction, these findings indicate that not accounting for ankle joint motion will produce unreliable results.  相似文献   

7.
These studies sought to investigate quantitative relationships between the complex composite structure and mechanical properties of tendon. The isolated mouse tail tendon fascicle was chosen as an appropriate model for these so-called "structure-function" investigations. Specifically, collagen fibril diameters and mechanical properties were measured in fascicles from immature (3 week) control, adult (8 week) control, and adult (8 week) MovI3 transgenic mice. Results demonstrated a moderate correlation between mean fibril diameter and fascicle stiffness (r = 0.73, p = 0.001) and maximum load (r = 0.75, p < 0.001), whereas a weak correlation with fascicle modulus (r = 0.39, p = 0.11) and maximum stress (r = 0.48, p = 0.04). An analysis of pooled within-group correlations revealed no strong structure-function trends evidenced at the local or group level, indicating that correlations observed in the general structure-function analyses were due primarily to having three different experimental groups, rather than significant correlations of parameters within the groups.  相似文献   

8.
A transversely isotropic biphasic mixture model was applied to tendon in uniaxial tension. Parametric analyses were performed and the sensitivity in predicting material parameters was evaluated. Our results provide quantitative evidence for fluid flow as a mechanism that contributes to tendon viscoelasticity. Transversely isotropic material properties were calculated for mouse tail tendon fascicles. The average transverse modulus (E(1)) was 0.046 MPa, the fiber-aligned Poisson's ratio (v(31)) was 2.73, and the transverse Poisson's ratio [(v(21)) was 0.96; these properties were not strain-dependent. The fiber-aligned modulus (E(s)) was strain-dependent and was 20.7 MPa in the toe region and 86.1 MPa in the linear region. These solid matrix properties were consistent with previously published tendon tissue and fascicle data. The fascicle permeability was strain-dependent and was 5.5 x 10(-18)m(4)/Ns in the toe region and 0.32 x 10(-18)m(4)/Ns in the linear region, similar to previously reported meniscus permeability in tension. The similar permeabilities of both fascicle and tissue-level samples suggest that fluid flow from individual fascicles, not the packing of multiple fascicles together, may be the primary barrier to fluid flow in tendon and thus the primary mechanism for viscoelasticity.  相似文献   

9.
Passive muscle stretching can be used in vivo to assess the viscoelastic properties of the entire musculo-articular complex, but does not allow the specific determination of the muscle or tendon viscoelasticity. In this respect, the local muscle hardness (LMH) of the gastrocnemius medialis (GM) belly was measured during a passive ankle stretching of 10 subjects using transient elastography. A Biodex isokinetic dynamometer was used to stretch ankle plantar flexors, to measure ankle angle, and the passive torque developed by the ankle joint in resistance to the stretch. Results show that the LMH increased during the stretching protocol, with an averaged ratio between maximal LMH and minimal LMH of 2.62+/-0.46. Furthermore, LMH-passive torque relationships were nicely fitted using a linear model with mean correlation coefficients (R(2)) of 0.828+/-0.099. A good reproducibility was found for the maximal passive torque (ICC=0.976, SEM=2.9Nm, CV=5.5%) and the y-intercept of the LMH-passive torque relationship (ICC=0.893, SEM=105Pa, CV=7.8%). However, the reproducibility was low for the slope of this relationship (ICC=0.631, SEM=10.35m(-2), CV=60.4%). The y-intercept of the LMH-passive torque relationship was not significantly changed after 10min of static stretching. This result confirms the finding of a previous study indicating that changes in passive torque following static stretching could be explained by an acute increase in muscle length without any changes in musculo-articular intrinsic mechanical properties.  相似文献   

10.
An important function of skeletal muscle is deceleration via active muscle fascicle lengthening, which dissipates movement energy. The mechanical interplay between muscle contraction and tendon elasticity is critical when muscles produce energy. However, the role of tendon elasticity during muscular energy dissipation remains unknown. We tested the hypothesis that tendon elasticity functions as a mechanical buffer, preventing high (and probably damaging) velocities and powers during active muscle fascicle lengthening. We directly measured lateral gastrocnemius muscle force and length in wild turkeys during controlled landings requiring rapid energy dissipation. Muscle-tendon unit (MTU) strain was measured via video kinematics, independent of muscle fascicle strain (measured via sonomicrometry). We found that rapid MTU lengthening immediately following impact involved little or no muscle fascicle lengthening. Therefore, joint flexion had to be accommodated by tendon stretch. After the early contact period, muscle fascicles lengthened and absorbed energy. This late lengthening occurred after most of the joint flexion, and was thus mainly driven by tendon recoil. Temporary tendon energy storage led to a significant reduction in muscle fascicle lengthening velocity and the rate of energy absorption. We conclude that tendons function as power attenuators that probably protect muscles against damage from rapid and forceful lengthening during energy dissipation.  相似文献   

11.
The fascicle material properties in bone-fascicle-bone units were determined for the anterior and posterior cruciate ligaments (ACL, PCL), the lateral collateral ligament (LCL) and the patellar tendon (PT) from three young human donor knees. Groups of fascicles from each tissue were isolated with intact bone ends and failed at a high strain rate in a saline bath at 37 degrees C. In each knee tested the load related material properties (linear modulus, maximum stress and energy density to maximum stress) for the patellar tendon were significantly larger than corresponding values for the cruciate and collateral ligaments. Bundles from different ligaments in the same knee were similar to each other in their mechanical behavior. In addition, no significant differences were present in the maximum strains recorded for any of the four tissue types examined. The results presented have implications in studies of ligament injury. They are also important in the design and use of synthetic and biological ligament replacements and in tissue and whole knee modeling.  相似文献   

12.
While microgravity exposure is known to cause deterioration of skeletal muscle performance, little is known regarding its effect on tendon structure and function. Hence, the aims of this study were to investigate the effects of simulated microgravity on the mechanical properties of human tendon and to assess the effectiveness of resistive countermeasures in preventing any detrimental effects. Eighteen men (aged 25-45 yr) underwent 90 days of bed rest: nine performed resistive exercise during this period (BREx group), and nine underwent bed rest only (BR group). Calf-raise and leg-press exercises were performed every third day using a gravity-independent flywheel device. Isometric plantar flexion contractions were performed by using a custom-built dynamometer, and ultrasound imaging was used to determine the tensile deformation of the gastrocnemius tendon during contraction. In the BR group, tendon stiffness estimated from the gradient of the tendon force-deformation relation decreased by 58% (preintervention: 124 +/- 67 N/mm; postintervention: 52 +/- 28 N/mm; P < 0.01), and the tendon Young's modulus decreased by 57% postintervention (P < 0.01). In the BREx group, tendon stiffness decreased by 37% (preintervention: 136 +/- 66 N/mm; postintervention: 86 +/- 47 N/mm; P < 0.01), and the tendon Young's modulus decreased by 38% postintervention (P < 0.01). The relative decline in tendon stiffness and Young's modulus was significantly (P < 0.01) greater in the BR group compared with the BREx group. Unloading decreased gastrocnemius tendon stiffness due to a change in tendon material properties, and, although the exercise countermeasures did attenuate these effects, they did not completely prevent them. It is suggested that the total loading volume was not sufficient to completely prevent alterations in tendon mechanical properties.  相似文献   

13.
The purpose of this study is to investigate age-dependent changes in the architecture and mechanical properties of tendon in TGF-beta inducible early gene-1 (TIEG) knockout mice. Wild-type and TIEG knockout mice, aged 1, 2, and 15 mo, were used. The mechanical properties of tail tendons isolated from these mice were determined using uniaxial tensile ramp (0.05 mm/s) and relaxation (5 mm/s) tests, with a strain of 10%. Mechanical parameters (Young's modulus from the ramp test; fast and static stresses from the relaxation test) were measured and recorded. The structure of the tail tendon fascicle was characterized by transmission electron microscopy. The results of the mechanical testing revealed no significant difference between the knockout and wild-type groups at 1 or 15 mo of age. However, the fascicles of the knockout mice at 3 mo of age exhibited decreased fast and static stresses compared with those of the wild-type mice. Electron microscopy revealed an increase in fibril size in the knockout mouse tendons relative to wild-type controls at 1 and 3 mo of age. These data indicate an important role for TIEG in tendon microarchitecture and strength in adult mice.  相似文献   

14.
The present study aimed to clarify the effects of knee joint angle on the behavior of the medial gastrocnemius muscle (MG) fascicles during eccentric plantar flexions. Eight male subjects performed maximal eccentric plantar flexions at two knee positions [fully extended (K0) and 90° flexed (K90)]. The eccentric actions were preceded by static plantar flexion at a 30° plantar flexed position and then the ankle joint was forcibly dorsiflexed to 15° of dorsiflexion with an isokinetic dynamometer at 30°/s and 150°/s. Tendon force was calculated by dividing the plantar flexion torque by the estimated moment arm of the Achilles tendon. The MG fascicle length was determined with ultrasonography. The tendon forces during eccentric plantar flexions were influenced by the knee joint angle, but not by the angular velocity. The MG fascicle lengths were elongated as the ankle was dorsiflexed in K0, but in K90 they were almost constant despite the identical range of ankle joint motion. These results suggested that MG fascicle behavior during eccentric actions was markedly affected by the knee joint angle. The difference in the fascicle behavior between K0 and K90 could be attributed to the non-linear force–length relations and/or to the slackness of tendinous tissues.  相似文献   

15.
Muscles generate force to resist gravitational and inertial forces and/or to undertake work, e.g. on the centre of mass. A trade-off in muscle architecture exists in muscles that do both; the fibres should be as short as possible to minimise activation cost but long enough to maintain an appropriate shortening velocity. Energetic cost is also influenced by tendon compliance which modulates the timecourse of muscle mechanical work. Here we use a Hill-type muscle model of the human medial gastrocnemius to determine the muscle fascicle length and Achilles tendon compliance that maximise efficiency during the stance phase of walking (1.2 m/s) and running (3.2 and 3.9 m/s). A broad range of muscle fascicle lengths (ranging from 45 to 70 mm) and tendon stiffness values (150-500 N/mm) can achieve close to optimal efficiency at each speed of locomotion; however, efficient walking requires shorter muscle fascicles and a more compliant tendon than running. The values that maximise efficiency are within the range measured in normal populations. A non-linear toe-region region of the tendon force-length properties may further influence the optimal values, requiring a stiffer tendon with slightly longer muscle fascicles; however, it does not alter the main results. We conclude that muscle fibre length and tendon compliance combinations may be tuned to maximise efficiency under a given gait condition. Efficiency is maximised when the required volume of muscle is minimised, which may also help reduce limb inertia and basal metabolic costs.  相似文献   

16.
Recent studies have suggested that the mechanical properties of aponeurosis are not similar to the properties of external tendon. In the present study, the lengths of aponeurosis, tendon, and muscle fascicles were recorded individually, using piezoelectric crystals attached to the surface of each structure during isometric contractions in the cat soleus muscle. We used a surgical microscope to observe the surface of the aponeurosis, which revealed a confounding effect on measures of aponeurosis length due to sliding of a thin layer of epimysium over the proximal aponeurosis. After correcting for this artifact, the stiffness computed for aponeurosis was similar to tendon, with both increasing from around 8 F0/Lc (F0 is maximum isometric force and Lc is tissue length) at 0.1 F0 to 30 F0/Lc at forces greater than 0.4 F0. At low force levels only (0.1 F0), aponeurotic stiffness increased somewhat as fascicle length increased. There was a gradient in the thickness of the aponeurosis along its length: its thickness was minimal at the proximal end and maximal at the distal end, where it converged to form the external tendon. This gradient in thickness appeared to match the gradient in tension transmitted along this structure. We conclude that the specific mechanical properties of aponeurosis are similar to those of tendon. © 1995 Wiley-Liss, Inc.  相似文献   

17.
Tendons transmit skeletal muscle forces to bone and are essential in all voluntary movement. In turn, movement appears to affect tendon properties, and in recent years considerable effort has been put into discovering how tendon tissue responds to mechanical stimuli in vivo. Months and years of mechanical loading can influence the gross morphology of tendon, seen as an increase tendon cross sectional area (CSA). Similarly, tendon stiffness appears to be affected by weeks to months of loading. Increased stiffness can relate to changes in CSA and/or tendon material properties (modulus), though the relative contribution of these parameters is largely unclear. The possible mechanisms behind alterations in tendon material properties include changes in collagen fibril morphology and levels of cross-linking between collagen molecules. Furthermore, increased levels of collagen synthesis and expression are seen as a response to acute exercise and training, and may be a central parameter in tendon adaptation to loading. There are indications that this collagen-induction relates to the auto-/paracrine action of collagen-stimulating growth factors, such as TGFβ-1 and IGF-I, which are expressed in response to mechanical stimuli.  相似文献   

18.
The different methods used to assess patellar tendon elongation in vivo may partly explain the large variation of mechanical properties reported in the literature. The present study investigated the effects of tracking landmark position and tibial point of resistive force application during leg extensions in a dynamometer.Nineteen adults performed isometric contractions with a proximal and distal dynamometer shank pad position. Knee joint moments were calculated employing an inverse dynamics approach. Tendon elongation was measured using the patellar apex and either the tibial tuberosity (T) or plateau (P) as tracking landmark.Using P for tracking introduced a bias towards greater values of tendon elongation at all force levels from 100 N to maximum tendon force (TFmax; p < 0.05). The differences between landmarks considering maximum tendon strain were greater at the proximal shank pad position (p < 0.05). Tendon stiffness was lower for P compared with T, but only in intervals up to 50% of TFmax (p < 0.05). The agreement between T and P for stiffness calculated between 50% and TFmax was acceptable with the distal, but poor with the proximal pad position.We demonstrated that using the tibia plateau and not the insertion as tracking landmark clearly affects the assessment of the force–elongation curve of the patellar tendon. However, using a distal point of resistive force application and calculating tendon stiffness between 50% and TFmax seems to yield an acceptable agreement between landmarks. These findings have important implications for the assessment of tendon properties in vivo and cross-study comparisons.  相似文献   

19.
Collagen is a triple-helical protein that forms various macromolecular organizations in tissues and is responsible for the biomechanical and physical properties of most organs. Second-harmonic generation (SHG) microscopy is a valuable imaging technique to probe collagen fibrillar organization. In this article, we use a multiscale nonlinear optical formalism to bring theoretical evidence that anisotropy of polarization-resolved SHG mostly reflects the micrometer-scale disorder in the collagen fibril distribution. Our theoretical expectations are confirmed by experimental results in rat-tail tendon. To that end, we report what to our knowledge is the first experimental implementation of polarization-resolved SHG microscopy combined with mechanical assays, to simultaneously monitor the biomechanical response of rat-tail tendon at macroscopic scale and the rearrangement of collagen fibrils in this tissue at microscopic scale. These experiments bring direct evidence that tendon stretching corresponds to straightening and aligning of collagen fibrils within the fascicle. We observe a decrease in the SHG anisotropy parameter when the tendon is stretched in a physiological range, in agreement with our numerical simulations. Moreover, these experiments provide a unique measurement of the nonlinear optical response of aligned fibrils. Our data show an excellent agreement with recently published theoretical calculations of the collagen triple helix hyperpolarizability.  相似文献   

20.
The objective of the present study was to investigate the age-related effects of submaximal static and cyclic loading on the mechanical properties of the vastus lateralis (VL) tendon and aponeurosis in vivo. Fourteen old and 12 young male subjects performed maximal voluntary isometric knee extensions (MVC) on a dynamometer before and after (a) a sustained isometric contraction at 25% MVC and (b) isokinetic contractions at 50% isokinetic MVC, both until task failure. The elongation of the VL tendon and aponeurosis was examined using ultrasonography. To calculate the resultant knee joint moment, the kinematics of the leg were recorded with eight cameras (120 Hz). The old adults displayed significantly lower maximal moments but higher strain values at any given tendon force from 400 N and up in all tested conditions. Neither of the loading protocols influenced the strain-force relationship of the VL tendon and aponeurosis in either the old or young adults. Consequently, the capacity of the tendon and aponeurosis to resist force remained unaffected in both groups. It can be concluded that in vivo tendons are capable of resisting long-lasting static (~4.6 min) or cyclic (~18.5 min) mechanical loading at the attained strain levels (4-5%) without significantly altering their mechanical properties regardless of age. This implies that as the muscle becomes unable to generate the required force due to fatigue, the loading of the tendon is terminated prior to provoking any significant changes in tendon mechanical properties.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号