首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
In this study, we aimed to compare the intrarater reliability and validity of muscle thickness measured using ultrasonography (US) and muscle activity via electromyography (EMG) during manual muscle testing (MMT) of the external oblique (EO) and lumbar multifidus (MF) muscles. The study subjects were 30 healthy individuals who underwent MMT at different grades. EMG was used to measure the muscle activity in terms of ratio to maximum voluntary contraction (MVC) and root mean square (RMS) metrics. US was used to measure the raw muscle thickness, the ratio of muscle thickness at MVC, and the ratio of muscle thickness at rest. One examiner performed measurements on each subject in 3 trials. The intrarater reliabilities of the % MVC RMS and raw RMS metrics for EMG and the % MVC thickness metrics for US were excellent (ICC = 0.81–0.98). There was a significant difference between all the grades measured using the % MVC thickness metric (p < 0.01). Further, this % MVC thickness metric of US showed a significantly higher correlation with the EMG measurement methods than with the others (r = 0.51–0.61). Our findings suggest that the % MVC thickness determined by US was the most sensitive of all methods for assessing the MMT grade.  相似文献   

2.
The aims of this study were to validate a computerised method to detect muscle activity from surface electromyography (SEMG) signals in gait in patients with cervical spondylotic myelopathy (CSM), and to evaluate the test–retest reliability of the activation times designated by this method. SEMG signals were recorded from rectus femoris (RF), biceps femoris (BF), tibialis anterior (TA), and medial gastrocnemius (MG), during gait in 12 participants with CSM on two separate test days. Four computerised activity detection methods, based on the Teager–Kaiser Energy Operator (TKEO), were applied to a subset of signals and compared to visual interpretation of muscle activation. The most accurate method was then applied to all signals for evaluation of test–retest reliability. A detection method based on a combined slope and amplitude threshold showed the highest agreement (87.5%) with visual interpretation. With respect to reliability, the standard error of measurement (SEM) of the timing of RF, TA and MG between test days was 5.5% stride duration or less, while the SEM of BF was 9.4%. The timing parameters of RF, TA and MG designated by this method were considered sufficiently reliable for use in clinical practice, however the reliability of BF was questionable.  相似文献   

3.
The aim of this study is to assess and compare the performance of commonly used hierarchical, partitional (k-means) and Gaussian model-based (Expectation–Maximization algorithm) clustering techniques to appropriately identify subgroup patterns within vertical ground reaction force data, using a continuous waveform analysis. In addition, we also compared the performance across each technique using normalized and non-normalization input scores. Both generated and real data (one hundred and twenty two vertical jumps) were analyzed. The performance of each cluster technique was measured by assessing the ability to explain variances in jump height using a stepwise regression analysis. Only k-means (normalized scores; 82%) and hierarchical clustering (normalized scores; 85%) were able to extend the ability to describe variances in jump height beyond that achieved using the group analysis (i.e. one cluster; 78%). Further, our findings strongly indicate the need to normalize the input data (similarity measure) when clustering. In contrast to the group analysis, the subgroup analysis was able to identify cluster specific phases of variance, which improved the ability to explain variances in jump height, due to the identification of cluster specific predictor variables. Our findings therefore highlight the benefit of performing a subgroup analysis and may explain, at least in part, the contrasting findings between previous studies that used a single group level of analysis.  相似文献   

4.
Surface electromyography (EMG) comprises a recording of electrical activity from the body surface generated by muscle fibres during muscle contractions. Its characteristics depend on the fibre membrane potentials and the neural activation signal sent from the motor neurons to the muscles. EMG has been classically used as the primary investigation tool in kinesiology studies in a variety of applications. More recently, surface EMG techniques have evolved from single-channel methods to high-density systems with hundreds of electrodes. High-density EMG recordings can be deconvolved to estimate the discharge times of spinal motor neurons innervating the recorded muscles, with algorithms that have been developed and validated in the last two decades. Within limits and with some variability across muscles, these techniques provide a non-invasive method to study relatively large populations of motor neurons in humans. Surface EMG is thus evolving from a peripheral measure of muscle electrical activity towards a neural recording and neural interfacing signal. These advances in technology have had a major impact on our fundamental understanding of the neural control of movement and have exposed new perspectives in neurotechnologies. Here we provide an overview and perspective of modern EMG technology, as derived from past achievements, and its impact in neurophysiology and neural engineering.  相似文献   

5.
PurposeNo direct evidence exists to support the validity of using surface electrodes to record muscle activity from serratus anterior, an important and commonly investigated shoulder muscle. The aims of this study were to determine the validity of examining muscle activation patterns in serratus anterior using surface electromyography and to determine whether intramuscular electromyography is representative of serratus anterior muscle activity.MethodsSeven asymptomatic subjects performed dynamic and isometric shoulder flexion, extension, abduction, adduction and dynamic bench press plus tests. Surface electrodes were placed over serratus anterior and around intramuscular electrodes in serratus anterior. Load was ramped during isometric tests from 0% to 100% maximum load and dynamic tests were performed at 70% maximum load. EMG signals were normalised using five standard maximum voluntary contraction tests.ResultsSurface electrodes significantly underestimated serratus anterior muscle activity compared with the intramuscular electrodes during dynamic flexion, dynamic abduction, isometric flexion, isometric abduction and bench press plus tests. All other test conditions showed no significant differences including the flexion normalisation test where maximum activation was recorded from both electrode types. Low correlation between signals was recorded using surface and intramuscular electrodes during concentric phases of dynamic abduction and flexion.ConclusionsIt is not valid to use surface electromyography to assess muscle activation levels in serratus anterior during isometric exercises where the electrodes are not placed at the angle of testing and dynamic exercises. Intramuscular electrodes are as representative of the serratus anterior muscle activity as surface electrodes.  相似文献   

6.
This study compared patterns of leg muscle recruitment and coactivation, and the relationship between muscle recruitment, coactivation and cadence, in novice and highly trained cyclists. Electromyographic (EMG) activity of tibialis anterior (TA), tibialis posterior (TP), peroneus longus (PL), gastrocnemius lateralis (GL) and soleus (SOL) was recorded using intramuscular fine-wire electrodes. Four experimental conditions of varying cadence were investigated. Differences were evident between novice and highly trained cyclists in the recruitment of all muscles. Novice cyclists were characterized by greater individual variance, greater population variance, more extensive and more variable muscle coactivation, and greater EMG amplitude in periods between primary EMG bursts. Peak EMG amplitude increased linearly with cadence and was not different at individual preferred cadence in either novice or highly trained cyclists. However, EMG amplitude in periods between primary EMG bursts, as well as the duration of primary EMG bursts, increased with increasing cadence in novice cyclists but were not influenced by cadence in highly trained cyclists. Our findings suggest that muscle recruitment is highly skilled in highly trained cyclists and less refined in novice cyclists. More skilled muscle recruitment in highly trained cyclists is likely a result of neuromuscular adaptations due to repeated performance of the cycling movement in training and competition.  相似文献   

7.
Muscle co-activation around the knee is important during ambulation and balance. The wide range of methodological approaches for the quantification of co-activation index (CI) makes comparisons across studies and populations difficult. The present study determined within- and between-session reliability of different methodological approaches for the quantification of the CI of the knee extensor and flexor muscles during maximum voluntary isometric contractions (MVICs). Eight healthy volunteers participated in two repeated testing sessions. A series of knee extension MVICs of the dominant leg with concomitant torque and electromyographic (EMG) recordings were captured. CI was calculated utilizing different analytical approaches. Intraclass correlation coefficient (ICC) showed that within-session measures displayed higher reliability (ICC > 0.861) and lower variability (Coefficient of variation; CV < 21.8%) than between-session measures (ICC < 0.645; CV > 24.2%). A selection of a 500 ms or larger window of RMS EMG activity around the PT delivered more reliable and less variable results than other approaches. Our findings suggest that the CI can provide a reliable measure for comparisons among conditions and is best utilized for within-session experimental designs.  相似文献   

8.
The purpose of this study was to examine the relative contributions of anthropometric variables to vertical jumping ability and leg power and to establish reference values of vertical jumping parameters in athletic Tunisian children aged 7-13 years in both sexes. Three hundred and ninety-one athletic Tunisian children (208 boys and 183 girls) aged 7-13 years were randomly selected to participate in our study. They were asked to perform squat jumps and countermovement jumps. Jump heights and leg power were simultaneously provided by the optojump device. Full and stepwise regression models were calculated to identify which anthropometric parameters significantly contributed to performance variables. The multiple regressions showed that age, weight, standing height and fat-free mass were the predictors of jumping performance. The results may help in verifying the effectiveness of a specific training program and detecting highly talented athletes.  相似文献   

9.
The aim of this meta-analysis regarding the use of surface electromyography (sEMG) is to assess the scientific evidence for detectable correlations between the masticatory system and muscle activity of the other body districts, particularly those mainly responsible for body posture. A literature survey was performed using the PubMed database, covering the period from January 1966 to April 2011, and choosing medical subject headings. After selection, five articles qualified for the final analysis. One study article was judged to be of medium quality, the remaining four of low quality. No study included a control group or follow-up; in only one study, subjects with impairment of the masticatory system were enrolled. In all studies, detectable correlations between the masticatory systems and muscle activity of the other body districts, or vice versa, were found; however, after a reappraisal of the data provided in these studies, only weak correlations were found, which reached biological, but not clinical relevance. With the limitations that arise from the poor methodological quality of the published study reports discussed here, the conclusion is that a correlation between the masticatory system and muscle activity of the other body districts might be detected through sEMG under experimental conditions; however, this correlation has little clinical relevance. While more investigations with improved levels of scientific evidence are needed, the current evidence does not support clinically relevant correlations between the masticatory system and the muscle activity of other body districts, including those responsible for body posture.  相似文献   

10.
High-density surface electromyography (HDsEMG) can be used to measure the spatial distribution of electrical muscle activity over the skin. As this distribution is associated with the generation and propagation of muscle fiber action potentials, HDsEMG is processed to extract information on regional muscle activation, muscle fiber characteristics and behaviour of individual motor units. This matrix, developed by the Consensus for Experimental Design in Electromyography (CEDE) project, summarizes recommendations on the use of HDsEMG in experimental studies. For each application, recommendations are included regarding electrode montage, electrode type and configuration, electrode location and orientation, data analysis, and interpretation. Cautions and reporting standards are also included. The steps of the Delphi process to reach consensus are contained in an appendix. This matrix is intended to help researchers when collecting, reporting, and interpreting HDsEMG data. It is hoped that this document will be used to generate new empirical evidence to improve how HDsEMG is used in research and in clinical applications.  相似文献   

11.
The aim of the present study was to verify the influence of distance between obstacles in combination for free jumping test on linear and temporal kinematic parameters of the jump. Investigated groups of halfbred stallions being prepared for 100 days performance test (two groups, 36 horses in total) were filmed on different distances between main doublebarre obstacle and last cross-pole in the jumping lane. Both groups of horses were filmed during their regular work in the same training centre 1 week before performance test. Jumping parameters were obtained on the same size of the obstacle. Data were analysed separately for both groups by analysis of variance. On the basis of the conducted study, it is possible to conclude that in the range of the most popular free jumping distance horses may use different jumping techniques to clear the jump. The shorter distances between last two obstacles in the jumping lane in the range of 6.8 to 7.1 m stimulate higher jumps; however, the reaction of horses was not exactly the same for all measured jumping parameters.  相似文献   

12.
PurposeThe reliability of lower extremity muscle activation patterns has not been clearly studied in a dual-belt instrumented treadmill environment. The primary study objective was to quantify the day-to-day reliability of quadriceps, hamstrings, gastrocnemius and gluteus medius activation patterns in healthy young adult gait. Secondarily, the reliability of spatiotemporal, and knee/hip motion and moment-based gait outcomes was assessed.Scope: 20 young adults were recruited and tested on two separate days. Using standardized procedures, participants were prepared for surface electromyography and lower extremity motion capture. All individuals walked on a dual-belt instrumented treadmill while muscle activation, segment motions and ground reaction forces were recorded. Sagittal plane motion and net external sagittal and frontal plane moments were calculated. Discrete biomechanical and muscle activation measures were calculated, and non-negative matrix factorization extracted amplitude and temporal muscle activation features. Intraclass Correlation Coefficients, Standard Error of Measurement and Minimum Detectable Change were calculated.ConclusionsHigh to excellent Intraclass correlation coefficients were found between visits for most primary and secondary outcomes. The absolute and relative reliability, including Minimum Detectable Change values, provided in this study support the use of dual-belt instrumented treadmill walking as an acceptable medium to collect biomechanical and lower extremity EMG outcomes for future studies.  相似文献   

13.
The purpose of this investigation was to observe the influence of increasing amounts of preactivity and eccentric muscle activity imposed by three different jump types on concentric vertical jumping performance. Sixteen athletes involved in jumping-related sports at Appalachian State University, which is a Division IA school, performed a static jump (SJ), counter-movement jump (CMJ), and drop jump (DJ). Force, power, velocity, and jump height were measured during each jump type. In addition, muscle activity was measured from two agonist muscles (vastus lateralis, vastus medialis) and one antagonist muscle (biceps femoris). Preactivity and eccentric phase muscle activity of the agonist muscles (average integrated electromyography) was significantly (p < or = 0.05) higher during the DJ (preactivity, 0.2 +/- 0.11 mV; eccentric phase, 1.00 +/- 0.36 mV) in comparison with the CMJ (preactivity, 0.11 +/- 0.10 mV; eccentric phase, 0.45 +/- 0.17 mV). Peak concentric force was highest during the DJ and was significantly different among all three jump types (SJ, CMJ, DJ). Maximal jump height was significantly higher during the DJ (0.41 +/- 0.05 m) and CMJ (0.40 +/- 0.06 m) compared with the SJ (0.37 +/- 0.07 m). However, no significant difference in jump height existed between the CMJ and DJ. A positive energy balance, as assessed by force-displacement curves during the eccentric and concentric phases, was observed during the CMJ, and a negative energy balance was observed during the DJ. The data from this investigation indicate that a significant increase in concentric vertical jump performance is associated with increased levels of preactivity and eccentric phase muscle activity (SJ to CMJ). However, higher eccentric loading (CMJ to DJ) leads to a negative energy balance during the eccentric phase, which may relate to a non-significant increase in vertical jump height, even with coincidental increases in peak concentric force. Practitioners may want to focus on improving eccentric phase muscle activity through the use of plyometrics to improve overall jumping performance in athletes.  相似文献   

14.
Normalization of electromyographic (EMG) amplitudes is necessary in the study of human motion. However, there is a lack of agreement on the most reliable and appropriate normalization method. This study evaluated the reliability of single leg stance (SLS) and maximal voluntary isometric contraction (MVIC) normalization methods and the relationship between these measures for the gluteus maximus (GMax), gluteus medius (GMed), rectus femoris (RF), vastus lateralis (VL), hip adductor group (ADD), and biceps femoris (BF). Surface EMG was recorded in 20 subjects during three 5 s trials of SLS and MVIC. SLS and MVIC methods both demonstrated good-to-excellent reliability in all muscles (ICCs > 0.80). Intrasubject coefficients of variation were lower for the MVIC method (9–36%) than for the SLS method (20–59%). EMG amplitudes during MVIC and SLS were significantly correlated for all muscles (Pearson r’s = 0.604–0.905, p < 0.005) except GMax (r = 0.250, p = 0.288). Use of SLS normalization for the RF, VL, and BF is not recommended due to a lack of measurement precision. However, this method is justified in the GMax, GMed, and ADD and may provide a better representation of coordinated muscle function during a functional task.  相似文献   

15.
The first aim was to investigate the impact of different electromyography (EMG) parameters as a reference to normalize the EMG amplitude of the superficial quadriceps femoris muscles across different sets of a knee extension exercise. The second aim is to examine the reliability between days of the EMG parameters used as a reference. Eleven young males attended the laboratory on 4 different days and performed one repetition maximum test, maximumvoluntary isometric contractions, and a resistance training protocol until failure. Surface EMG was placed over the rectus femoris, vastus lateralis, and vastus medialis muscles. Seven EMG parameters were calculated from the tasks and used to normalize EMG amplitude measured during the resistance training protocol. A repeated-measures two-way ANOVA was used (normalized EMG amplitude × set) to compare normalized EMG across sets, while an intraclass correlation coefficient, coefficient of variation, and Bland-Altman plots were used to calculate the intra-day reliability of the EMG parameters. The present investigation showed that normalized EMG amplitude of the superficial muscles of the quadriceps measured during a knee extension exercise is influenced by the EMG parameter and depends on the muscle. While rectus femoris and vastus lateralis normalized EMG amplitude presented one parameter among seven showing similar value to the other parameters, VM showed two. Lastly, all EMG parameters for all muscles presented an overall excellent reliability and agreement between days.  相似文献   

16.
Determining muscle contractile properties following exercise is critical in understanding neuromuscular function. Following high intensity training, individuals often experience exercise induced muscle damage (EIMD). The purpose of this investigation was to determine the effect of whole-body vibration (WBV) on muscle contractile properties following EIMD. Twenty-seven females volunteered for 7 sessions and were randomly assigned to a treatment or control group. Muscle contractile properties were assessed via voluntary torque (VT), peak twitch torque (TT), time to reach peak torque, half relaxation time of twitch torque, percent activation (%ACT), rate of rise (RR), rate of decline (RD), mean and peak electromyography during maximum voluntary isometric contraction. Two testing sets were collected each day, consisting of pre measures followed by WBV or control and post measures. A mixed factor analysis of variance was conducted for each variable. %ACT measures found baseline being less than day 1 in both measures in the control group. TT was found to be greater in the control group compared to WBV group. TT and VT baseline measures were greater than all other time points. RR showed control group had higher values than WBV group. These results indicate that WBV following EIMD had some positive effects on muscle contractile properties.  相似文献   

17.
The effect of muscle stimulation dynamics on the sensitivity of jumping achievement to variations in timing of muscle stimulation onsets was investigated. Vertical squat jumps were simulated using a forward dynamic model of the human musculoskeletal system. The model calculates the motion of body segments corresponding to STIM(t) of six major muscle groups of the lower extremity, where STIM is muscle stimulation level. For each muscle, STIM was allowed to switch “on” only once. The subsequent rise of STIM to its maximum was described using a sigmoidal curve, the dynamics of which was expressed as rise time (RT). For different values of stimulation RT, the optimal set of onset times was determined using dynamic optimization with height reached by the center of mass as performance criterion. Subsequently, 200 jumps were simulated in which the optimal muscle stimulation onset times were perturbed by adding to each a small number taken from a Gaussian-distributed set of pseudo-random numbers. The distribution of heights achieved in these perturbed jumps was used to quantify the sensitivity of jump height to variations in timing of muscle stimulation onsets. It was found that with increasing RT, the sensitivity of jump height to timing of stimulation onset times decreased. To try and understand this finding, a post-hoc analysis was performed on the perturbed jumps. Jump height was most sensitive to errors in the delay between stimulation onset times of proximal muscles and stimulation onset times of plantar flexors. It is explained how errors in this delay cause aberrations in the configuration of the system, which are regenerative and lead to relatively large jump height deficits. With increasing RT, the initial aberrations due to erroneous timing of muscle stimulation are smaller, and the regeneration is less pronounced. Finally, it is speculated that human subjects decrease or increase RT depending on the relative importance of different performance criteria. Received: 16 February 1998 / Accepted in revised form: 1 March 1999  相似文献   

18.
Mechanical efficiency (ME) of jumping exercises was compared between power-trained (n = 11) and endurance-trained athletes (n = 10) using both a biomechanical and a physiological approach. In drop jumps and in stretch-shortening cycle exercise on a special sledge (sledge jumps), the subjects performed 60 muscle actions from a dropping height of optimum minus 40 cm (O – 40), as well as from dropping heights of optimum (O) and optimum plus 40 cm (O + 40). Thus, they were tested in six different tests which lasted for a total of 3 min for each. The mean ME values in the drop jumps from the lowest dropping height upwards were as follows: 23.8 (SD 5.3)%, 35.5 (SD 10.8)% and 39.2 (SD 6.6)% for the power group, and 30.8 (SD 6.5)%, 37.5 (SD 8.7)% and 41.4 (SD 7.0)% for the endurance group. In the sledge jumps the ME values were 37.0 (SD 5.6)%,48.4 (SD 4.0)% and 54.9 (SD 8.5)% for the power group, and 40.2 (SD 5.9)%, 46.9 (SD 5.7)% and 58.5 (SD 5.5)% for the endurance group. As can be seen, the ME values increased with increasing stretch load. However, the groups did not differ from each other except in the drop jump condition of O – 40 (P < 0.05). The higher power (P < 0.001) among the power athletes in every measured condition was associated with a faster rate of electromyogram development during the pre-activity, and smoother muscle activity patterns in the ground contact. On the other hand, the endurance athletes had a lower blood lactate concentration after every test, and in addition a lower heart rate and ventilation during the sledge jumps than their power counterparts. Therefore, it would seem that the similar mean ME values between the subject groups could be explained by improved function of the neuromuscular system among the power group and improved metabolism among the endurance group.  相似文献   

19.
PurposeTo establish intra- and inter-session reliability of high-density surface electromyography (HDEMG)-derived parameters from the thoracic erector spinae (ES) during static and dynamic goal-directed voluntary movements of the trunk, and during functional reaching tasks.MethodsTwenty participants performed: 1) static trunk extension, 2) dynamic trunk forward and lateral flexion, and 3) multidirectional functional reaching tasks on two occasions separated by 7.5 ± 1.2 days. Muscle activity was recorded bilaterally from the thoracic ES. Root mean square (RMS), coordinates of the barycentre, mean frequency (MNF), and entropy were derived from the HDEMG signals. Reliability was determined with intraclass correlation coefficient (ICC), coefficient of variation, and standard error of measurement.ResultsGood-to-excellent intra-session reliability was found for all parameters and tasks (ICC: 0.79-0.99), whereas inter-session reliability varied across tasks. Static tasks demonstrated higher reliability in most parameters compared to functional and dynamic tasks. Absolute RMS and MNF showed the highest overall reliability across tasks (ICC: 0.66-0.98), while reliability of the barycentre was influenced by the direction of the movements.ConclusionRMS and MNF derived from HDEMG show consistent inter-session reliability in goal-directed voluntary movements of the trunk and reaching tasks, whereas the measures of the barycentre and entropy demonstrate task-dependent reliability.  相似文献   

20.
There are no direct recordings of obturator internus muscle activity in humans because of difficult access for electromyography (EMG) electrodes. Functions attributed to this muscle are based on speculation and include hip external rotation/abduction, and a role in stabilization as an “adjustable ligament” of the hip. Here we present (1) a technique to insert intramuscular EMG electrodes into obturator internus plus (2) the results of an investigation of obturator internus activity relative to that of nearby hip muscles during voluntary hip efforts in two hip positions and a weight-bearing task. Fine-wire electrodes were inserted with ultrasound guidance into obturator internus, gluteus maximus, piriformis and quadratus femoris in ten participants. Participants performed ramped and maximal isometric hip efforts (open kinetic chain) into flexion/extension, abduction/adduction, and internal/external rotation, and hip rotation to end range in standing. Analysis of the relationship between activity of the obturator internus and the other hip muscles provided evidence of limited contamination of the recordings with crosstalk. Obturator internus EMG amplitude was greatest during hip extension, then external rotation then abduction, with minimal to no activation in other directions. Obturator internus EMG was more commonly the first muscle active during abduction and external rotation than other muscles. This study describes a viable and valid technique to record obturator internus EMG and provides the first evidence of its activation during simple functions. The observation of specificity of activation to certain force directions questions the hypothesis of a general role in hip stabilisation regardless of force direction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号